Agriculture Government Departments Closing in 7 days TDR #56295531

Tender For Providing Subheads Lift Irrigation Components Including Distribution System At Twis Babehar Under Hpcdp (Phase-Ii) Project-Jica-Oda Phase-Ii At Village Babehar, G.P Babehar, Tehsil Ghanari, Distt. Una (H.P.)

Issued by Government Departments · Una, Himachal Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
14 Jul 2026
7 days left
EMD
1.05 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Una → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Providing Subheads Lift Irrigation Components Including Distribution System At Twis Babehar Under Hpcdp (Phase-Ii) Project-Jica-Oda Phase-Ii At Village Babehar, G.P Babehar, Tehsil Ghanari, Distt. Una (H.P.)

BOQ

Name of Work:- Providing Subheads Lift irrigation Components including Distribution System at TWIS Babehar under HPCDP (Phase-II) Project-JICA-ODA Phase-II at Village Babehar, G.P Babehar, Tehsil Ghanari, Distt. Una (H.P.)
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation, trenches or drains, pits upto all depths in all classification of earth work such as pick work, jumper work, saturated soil including bailing and pumping out water, chieselling soft / hard rock including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil in ordinary rock as directed, within all leads and lifts complete in all respect and to the entire satisfaction of the Engineer-in-Charge.
2Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and then disposing of surplus excavated soil as directed, within all lead and lifts including restoration of unmettalled surfaces to its original condition complete in all respect and to the entire satisfaction of the Engineer-in-Charge.
3Boulder / Stone filling under floor/ apron / behind retaining walls with consolidating & dressing etc. complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
4Supplying and filling in plinth with sand under floors,including watering,ramming,consolidating and dressing complete in all respect as per entire satisfaction of engineer in charge
5Centering and shuttering including strutting, propping etc. and removal of form work for:
6Foundations,Footing,Bases for columns for mass concrete complete in all respect within all leads and lifts and to the entire satisfaction of the engineer-in-charge. etc.
7Circular walls (any thickness) including attached pilasters, butteresses, plinth and string courses in complete in all respect within all leads and lifts and to the entire satisfaction of the engineer-in-charge.
8Suspended floors,Roofs,landings,balconies and access platform complete in all respect to the entire satisfaction of Engineer-in-Charge
9Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
10Lintels, beams, plinth beams, girders, bressumers and cantilevers complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
11Edges of slabs and breaks in floors and walls complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
12Providing Mild steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
13Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
14Providing and laying in position cement concrete 1:4:8 (1 Cement: 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) and curing complete excluding the cost of centering and shuttering complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
15Providing and laying in position cement concrete 1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) all work upto plinth level excluding the cost of shuttering and centering complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
16Providing and laying in position reinforced cement concrete 1:1.5:3 (1cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size) and curing complete in :
17Foundation & plinth excluding the cost of centering, shuttering & reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
18In walls (any thickness),in retaining walls,return walls, including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level upto all level, excluding the cost of centering, shuttering and reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
19Beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above or below plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-charge.
20Providing and laying in position reinforced cement concrete 1:1:2 ( 1cement : 1 sand : 2 graded stone aggregate 20 mm nominal size) and curing complete:
21In foundation,pinth, beams, , excluding the cost of centering, shuttering and reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
22In vertical walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level upto all level, excluding the cost of centering, shuttering and reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
23Providing and laying Damp Proof Corse 40mm thick with neat cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 10 mm nominal size) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-charge.
24Providing and laying cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) in foundation and plinth complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-charge.
25Providing and laying in position cement concrete 1:5:10 (1 Cement: 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) in foundation and plinth and curing complete excluding the cost of centering and shuttering complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
26Providing 40 mm thick cement concrete flooring in 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate,20 mm nominal Size) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
27Random rubble Masonary with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 ((1 cement : 6 coarse sand : 12 graded stone aggregate) 20mm nominal size upto plinth level complete in all respect to the entire satisfactiopn of Engineer-in-Charge
28Brick work with common burnt clay F.P.C. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shape and sizes in cement mortar 1:6 (1 cement:6 Sand) complete in all respect with all leads and lifts and to the entire satisfaction of the Engineer-in Charge.
29Half Burnt brick with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in Charge
306 mm cement plaster on the rough side of brick wall in cement mortar 1:3 (1 cement: 3 Coarse sand) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
3115 mm cement plaster on the rough side of brick wall in cement mortar 1:4 (1 cement: 4 Coarse sand) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
32Providing and fixing 1mm thick M.S. sheetsliding shutters with frame and diagonal braces or 40x40x6 mm angle iron 3. M.S. gusset plates at junctions and corner 25 mm dia pully 40x40x6 mm angle and T-iron guide at the top and bottom respectively, including applying a primer coat of red lead paint complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
33Providing and fixing M.S. round or square bars with M.S. flats at required spacing in wooden/ steel frames of windows and clerestory windows (M.S. grill) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
34Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
35Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35 x 35 x 5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
36Providing and fixing ISI marked oxidised M.S. sliding door bolts anopdized 250*16mm with nuts and screws etc. complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
37Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
38Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
39Providing & Fixing on wall face unplasticised Rigid PVC rain water pipes confirming to IS 13592 Type A including jointing with seal ring confirming to IS 5382 leaving 10mm gap for thermal expansion single socketed pipes of 110 mm Dia U-PVC pipes complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
40Providing & Fixing on wall face unplasticised PVC moulded fitting/accessories for unplasticised Rigid PVC rain water pipes confirming to IS 13592 Type A including jointing with seal ring confirming to IS 5382 leaving 10mm gap for thermal expansion single pushfir coupler of 110 mm dia. complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
41Providing & Fixing on wall face unplasticised PVC moulded fitting/accessories for unplasticised Rigid PVC rain water pipes confirming to IS 13592 Type A including jointing with seal ring confirming to IS 5382 leaving 10mm gap for thermal expansion bend 87.5° of 110 mm dia. complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
42Providing & Fixing on wall face unplasticised PVC moulded fitting/accessories for unplasticised Rigid PVC rain water pipes by means of 50*50*50 mm hard wood plugs,screwed with M.S screws of required length,including cutting brick work and fixing in cement mortar 1:4 (1 Cement:4 coarse sand ) and making the good wall etc complete of 110mm Dia complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
43Finishing with epoxy paint (two or more coats) at all locations prepared on steel work and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
44White washing with lime to give an even shade New Work (three or more coats) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
45Finishing walls with water proofing cement paint of required shade: New Work (Two or more costs applied @ 3.84 kg/10sqm) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
46Providing and fixing M.S fan clamp type 1 of 16 mm dia M.S bar bent to shape with hooked ends in R.C.C slab during laying including painting the exposed portion of loop, all as per standard design complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
47Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in Charge
48Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement:3 coarse sand: 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nomial size,well rammed and consolidated and grouted with fine sand,including necessary excavation,levelling & dressing & finishing the top smooth in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
49Providing, laying, jointing, commissioning and testing in trenches (to level or grade) GMS tubes confirming to IS : 1239 : 2004 of 150 mm dia, medium class with all necessary fittings conforming to IS specification capable to withstand the required hydraulic test pressure as per IS code in random length of 6.00 mtrs. including flushing , cleaning and hydraulic testing of pipe for rising main from intake to sump well complete in all respect within all leads and lifts and to the entire satisfaction of Engineer-in-Charge.
50Providing, laying, jointing, commissioning and testing in trenches (to level or grade) GMS tubes confirming to IS : 1239 : 2004 of 125 mm dia, medium class with all necessary fittings conforming to IS specification capable to withstand the required hydraulic test pressure as per IS code in random length of 6.00 mtrs. including flushing , cleaning and hydraulic testing of pipe for rising main from intake to sump well complete in all respect within all leads and lifts and to the entire satisfaction of Engineer-in-Charge.
51Providing, laying, jointing, commissioning and testing in trenches (to level or grade) GMS tubes confirming to IS : 1239 : 2004 of 125 mm dia, medium class with all necessary fittings conforming to IS specification capable to withstand the required hydraulic test pressure as per IS code in random length of 6.00 mtrs. including flushing , cleaning and hydraulic testing of pipe for rising main from intake to sump well complete in all respect within all leads and lifts and to the entire satisfaction of Engineer-in-Charge.
52Providing, laying, jointing, commissioning and testing in trenches (to level or grade) GMS tubes confirming to IS : 1239 : 2004 of 80 mm dia, medium class with all necessary fittings conforming to IS specification capable to withstand the required hydraulic test pressure as per IS code in random length of 6.00 mtrs. including flushing , cleaning and hydraulic testing of pipe for rising main from intake to sump well complete in all respect within all leads and lifts and to the entire satisfaction of Engineer-in-Charge.
53Providing, laying, jointing, commissioning and testing in trenches (to level or grade) GMS tubes confirming to IS : 1239 : 2004 of 65 mm dia, medium class with all necessary fittings conforming to IS specification capable to withstand the required hydraulic test pressure as per IS code in random length of 6.00 mtrs. including flushing , cleaning and hydraulic testing of pipe for rising main from intake to sump well complete in all respect within all leads and lifts and to the entire satisfaction of Engineer-in-Charge.
54Providing, laying, jointing, commissioning and testing in trenches (to level or grade) GMS tubes confirming to IS : 1239 : 2004 of 50 mm dia, medium class with all necessary fittings conforming to IS specification capable to withstand the required hydraulic test pressure as per IS code in random length of 6.00 mtrs. including flushing , cleaning and hydraulic testing of pipe for rising main from intake to sump well complete in all respect within all leads and lifts and to the entire satisfaction of Engineer-in-Charge.
55Providing, welding and fixing of M.S. flanges of joints at suitable reaches, conforming to table 5 as per IS:6392-1971 (latest with upto date amendments) with plain end and welding of MS Flanges with G.I. Pipes/ MSERW pipes of 150 mm dia in two layers on both faces to make the joint leak proof (the cost of providing and laying of G.I.Pipes to be measured and paid for separately). The welding of flanges should conform to IS 816-1969 with electrode as per IS : 814-1991 and required number of nuts & bolts conforming to IS: 1364 including cost of gasket sheet nuts & bolts. The thickness of gasket not less than 3.00 mm conforming to IS : 2712-1998 from Flange table 5. The work shall be done as per entire satisfaction of Engineer-in-Charge within all leads and lifts complete to the entire satisfaction of engineer-in charge
56Providing, welding and fixing of M.S. flanges of joints at suitable reaches, conforming to table 5 as per IS:6392-1971 (latest with upto date amendments) with plain end and welding of MS Flanges with G.I. Pipes/ MSERW pipes of 65 mm dia in two layers on both faces to make the joint leak proof (the cost of providing and laying of G.I.Pipes to be measured and paid for separately). The welding of flanges should conform to IS 816-1969 with electrode as per IS : 814-1991 and required number of nuts & bolts conforming to IS: 1364 including cost of gasket sheet nuts & bolts. The thickness of gasket not less than 3.00 mm conforming to IS : 2712-1998 from Flange table 5. The work shall be done as per entire satisfaction of Engineer-in-Charge within all leads and lifts complete to the entire satisfaction of engineer-in charge
57Providing, welding and fixing of M.S. flanges for delivery pipe, conforming to table 5 as per IS:6392-1971 (latest with upto date amendments) with plain end and welding of MS Flanges with G.I. Pipes/ MSERW pipes of 125 mm dia in two layers on both faces to make the joint leak proof (the cost of providing and laying of G.I.Pipes to be measured and paid for separately). The welding of flanges should conform to IS 816-1969 with electrode as per IS : 814-1991 and required number of nuts & bolts conforming to IS: 1364 including cost of gasket sheet nuts & bolts. The thickness of gasket not less than 3.00 mm conforming to IS : 2712-1998 from Flange table 5. The work shall be done as per entire satisfaction of Engineer-in-Charge within all leads and lifts complete to the entire satisfaction of engineer-in charge
58Providing, welding and fixing of M.S. flanges for delivery pipe, conforming to table 5 as per IS:6392-1971 (latest with upto date amendments) with plain end and welding of MS Flanges with G.I. Pipes/ MSERW pipes of 50 mm dia in two layers on both faces to make the joint leak proof (the cost of providing and laying of G.I.Pipes to be measured and paid for separately). The welding of flanges should conform to IS 816-1969 with electrode as per IS : 814-1991 and required number of nuts & bolts conforming to IS: 1364 including cost of gasket sheet nuts & bolts. The thickness of gasket not less than 3.00 mm conforming to IS : 2712-1998 from Flange table 5. The work shall be done as per entire satisfaction of Engineer-in-Charge within all leads and lifts complete to the entire satisfaction of engineer-in charge
59Providing circumferencial Butt welded joints by electrical arc welding to G.I pipe of 150 mm dia,welded in requisite numbers of weld runs to make the joint leak proof so as to achieve the minimum effective throat thickness of weld conforming to IS 816-1969 specifications, by using welding electrodes of 2.5 mm to 6.3 mm of Advani Oerlikon (Adore) - Citojet / ESAB make conforming to IS 814-1991, at site of work complete in all respect including manual/mechanical handling of pipes in all leads and lifts to the entire satisfaction of Engineer-in-Charge.
60Providing circumferencial Butt welded joints by electrical arc welding to G.I pipe of 80 mm dia,welded in requisite numbers of weld runs to make the joint leak proof so as to achieve the minimum effective throat thickness of weld conforming to IS 816-1969 specifications, by using welding electrodes of 2.5 mm to 6.3 mm of Advani Oerlikon (Adore) - Citojet / ESAB make conforming to IS 814-1991, at site of work complete in all respect including manual/mechanical handling of pipes in all leads and lifts to the entire satisfaction of Engineer-in-Charge.
61Providing circumferencial Butt welded joints by electrical arc welding to G.I pipe of 65 mm dia,welded in requisite numbers of weld runs to make the joint leak proof so as to achieve the minimum effective throat thickness of weld conforming to IS 816-1969 specifications, by using welding electrodes of 2.5 mm to 6.3 mm of Advani Oerlikon (Adore) - Citojet / ESAB make conforming to IS 814-1991, at site of work complete in all respect including manual/mechanical handling of pipes in all leads and lifts to the entire satisfaction of Engineer-in-Charge.
62Interlink Chain (Galvanized Steel Chain link Fence fabric ) intended for various purposes confirming ti IS 2721-2003, hot dip galvanished as per IS 4826:1979.The wire shall be Hot dipped galvanished heavy quoted, mass zinc coating as per IS 4826-1979. The fenci g material shall be made from steel wire, confirming to IS 280:2006, helical wound and inter woven in such a manner to provide a continous mesh wothout knots or ties except in the form of knuckling the ends of the wires to from both ends knocked selvage of the fabric. The width of fabric shall be .90m.1.20m,1.50m,1.80m,2.00m,2.50m and 3.00m or as per the requirment of the purchaser. The fabric shall be supplied in rolls of 5.0m, 10.0m, 15.0m and 25m or as per the requirment of the purchaser, of wire and mesh as specified below: 150+5mm mesh with nominal dia of wesh wire 5.00 m
63Providing & Fixing reputed make flexible steel water storage tank confirming to BIS 15961:2012. Tanks outer wall shall be of corrugated profile Zincalumer Steel (Wall Sheet Corrugation 75 mm to 16 mm) with overlap bolted panel, wall sheet elongation 18%, Tensile Strength 550 N/mm². Panel including vertical/curved surface fixed with polymer coated steel bolts and nuts with G.I. limpet washers (washers & seals material neoprene backed) or with G.I. filled with white lead as per EN ISO 10684:2004 with resistance class 8.8, Min. Yield Strength 640 N/mm² & Tensile Strength 800 N/mm², including the cost of vertical support and cutting to size and shape upto 1.00 mm thick with zinc coating not less than 286 gm/m².Further, P/F intermediate layer of Inside Liner/Membrane (made of PVC, compressed with multi-layer nylon mesh with options EPDM or Butyl Rubber, Non Sticky, Chemically Stabilized, U-V Stabilized, Anti Algae) having thickness of 0.75 mm and weight 900 GSM, Tensile Strength 6.5 kN/m, Elongation 55% and UV Stability @500 hrs 70% with anchoring sheet complete with ANSI/NSF61/BIS 15351:2015 certified HDPE liner.The Roof of the Tank shall be (Flat Roof Type) with Roof Supporting Structures supported by rafters & trusses and covered pre-coated galvanised iron sheets with 1 mm thickness, Load bearing capacity of 300 kg/sqm, tensile strength 550 MPa, 0.50 mm (+0.05%) total coated thickness with zinc coating as per IS:277 and epoxy primer on both side of the sheet and polyester top coat.Installation should be complete with requisite site civil works for bed preparation, accessories, Nozzle fitting for Outlet, Overflow & Inlet Pipe) will be completed with flanges and double back plate support to avoid load transfer on wall should be done as per the DPR & direction & satisfaction of the engineer in-charge. Nozzle fixing sealants should includes Strip Seal with Adhesion tensile 400 N, Adhesion Shear 12 N/mm², insoluble in water.Including Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains, including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within all leads and lifts. (Item Code HPPWDSR 2020 - Chapter 2.8) All kinds of soil and for Foundation Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering – All work up to plinth level 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) (Item Code HPPWDSR 2020 - Chapter 4.1.6)
64Fencing with angle iron posts placed at required distance embedded in cement concrete block,every 15th post,last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and diagonals interwoven with horizontal wires,of barbed wire weighing 9.38 Kg per 100m(minimum),between the two posts fitted and fixed with G.I Staples,turn buckles etc complete in all respect within all leads and lift.complete to the entire satisfaction of Engineer-in-Charge.
65Providing & Fixing CI Sluice Valve 150 mm dia @ 10.2 Kg/cmˆ2 Kartar make i/c MS Flange of table as per IS 6392-1971 of 5WT of 71.30 Kg & Welding of MS Flanges in two layers on both faces & i/c carriges in all respect within all leads and lift.complete to the entire satisfaction of Engineer-in-Charge.
66Providing & Fixing CI Sluice Valve 125 mm dia @ 10.2 Kg/cmˆ2 Kartar make i/c MS Flange of table as per IS 6392-1971 of 5WT of 56.30 Kg & Welding of MS Flanges in two layers on both faces & i/c carriges in all respect within all leads and lift.complete to the entire satisfaction of Engineer-in-Charge.
67Providing & Fixing CI Sluice Valve 80 mm dia @ 10.2 Kg/cmˆ2 Kartar make i/c MS Flange of table as per IS 6392-1971 of 5WT of 31.30 Kg & Welding of MS Flanges in two layers on both faces & i/c carriges in all respect within all leads and lift.complete to the entire satisfaction of Engineer-in-Charge.
68Providing & Fixing CI Sluice Valve 65 mm dia @ 10.2 Kg/cmˆ2 Kartar make i/c MS Flange of table as per IS 6392-1971 of 5WT of 23.30 Kg & Welding of MS Flanges in two layers on both faces & i/c carriges in all respect within all leads and lift.complete to the entire satisfaction of Engineer-in-Charge.
69Providing & Fixing CI Non Return Valve 150 mm dia @ 10.2 Kg/cmˆ2 Kartar make i/c MS Flange of table as per IS 6392-1971 of 5WT of 83.00Kg & Welding of MS Flanges in two layers on both faces & i/c carriges in all respect within all leads and lift.complete to the entire satisfaction of Engineer-in-Charge.
70Providing & Fixing CI Non Return Valve 65 mm dia @ 10.2 Kg/cmˆ2 Kartar make i/c MS Flange of table as per IS 6392-1971 of 5 WT of 23.30 Kg & Welding of MS Flanges in two layers on both faces & i/c carriges in all respect within all leads and lift.complete to the entire satisfaction of Engineer-in-Charge.
71Providing & Fixing PP Ball Valve 63 mm Dia.complete including necessary fitings (Reducer,bend,tee,flange) & all accessories complete in all respect to the entire satisfaction of Engineer-in-Charge
72Providing & Fixing PP Ball Valve 90 mm Dia.complete including necessary fitings (Reducer,bend,tee,flange) & all accessories complete in all respect to the entire satisfaction of Engineer-in-Charge
73Providing & Fixing PP Ball Valve 75 mm Dia.complete including necessary fitings (Reducer,bend,tee,flange) & all accessories complete in all respect to the entire satisfaction of Engineer-in-Charge
74Providing & Fixing Puddler Collar 80 mm Dia.complete including necessary fitings (Reducer,bend,tee,flange) & all accessories complete in all respect to the entire satisfaction of Engineer-in-Charge
75Providing & Fixing Butterfly valve of 25 mm Dia with G.I Socket of 25 mm Dia Tee & GI nipple of 25mm Dia in Distribution System including jointing and fitting complete in all respect to the entire satisfaction of Engineer-in-Charge
76Providing and fixing HDPE Air Release Valve of 25 mm dia with G.I Socket of 25 mm Dia. Tee & GI Nipple of 25 mm Dia. in Distribution System including Jointing & fitting complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
77Providing GMS Tube (IS:-1239:2004) of 25 mm Dia & medium class confriming to IS Specification capable to withstand the required hydraulic test pressure as per IS Code in random length of 6.00 mtr.complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
78Providing Chain Pulley having capacity of 1 Ton
79Providing ,laying ,jointing and testing and testing in trenches to (level or grade) HDPE pipes of following dia (H/M) class conforming to IS 4984,PE-100and jointing the pipes through push type compression joints by hydraullically operated machines upto 110 mm diameter & butt fusion (Heat fusion process) above 110 mm diameter i.e necessary fittings,bends,tees & reducers fabricated in accordance with IS 8360 & IS 8008 with latest amendments & shall be provided as per site conditions.Flanging of the pipes shall be made as & where required confirming to code IS 8008 & IS 7634,stub ends will be welded on pipes & MS Flange shall be provided with slip on covered by epoxy coating/plastic powder.The flange should be confirm to ANSI B 16.5 with necessary nuts & bolts.Jointing shall be complete in all respects to the entire satisfaction of Engineer-incharge including entire carriage of materials upto all leads and lifts.
8063 mm ;PN 6 class,PE-100
8175 mm ;PN 6 class,PE-100
8290 mm ;PN 6 class,PE-100
83Writing new letters and figures of any shade with synthetic enamel black or any other approved colour to give n even shade as per drawings and in English & Roman ,Hypen,Commas, and the like not to be measured and paid for complete to the entire satisfaction of Engineer-in-Charge
84Supply of Vertical submersible pumping set of KSB /BS/Johnstion/oswal/Crompton/Kirloskar/Calama make comprising to latest relevant BIS Code or any other make approved make by HPJSV. The pump should be fitted with bronze impeller of suitable alloys as per IS 8034-1976 latest suitable for Clear water having greased packed bearings and shaft with wound stator on motor side and with soft protection sleeve on pump side ensuring better life for shaft coupled to a submersible squirrel cage electric induction motor (water proof type) of required HP, RPM 2900 of reputed make conforming to BIS 9238-1979 latest with upto date amendments, totally dust and water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand non vertical loads with minimum wear and tear. It should also be fitted with a device to take up expansion of water with the heating of motor. The pump set should include all items containing item no. 70.01 & 70.78, water level guards, erection clamps , cable clips and depth gauge etc. and suitable for operation on data given below:-
85SITE CONDITIONS:-
86Location of site:Babehar (1st Stage)
87The altitude of place in which the motor is intended to work in ordinary service
88Humidity:- Humid during rainy season
89Nature of atmosphere:-Normal
90Detail of quality of water:- Clear water
91Water free from sand or not:-Free from sand
92Water corrosive or not:-Not corrosive
93Turbidity:-<50 ppm
94Any other information if required.
95OPERATING CONDITIONS
96Type of current:- AC. Three phase
97Operating frequency :-50 Hz.
98Rated voltage- 400(+/-) 10% volts.
99System of earthing if any to be adopted-Double loop earthing
100Speed of revolution-To be quoted by tenderer .
101Direction of rotation- to be quoted by tender
102No. of working hours per day:-20 hours
103The maximum temperature of cooling air and water in the place in which the pump set is intended to work in ordinary service:- Temprature of place to be 20°C to 42°C
104MOTOR-
105Ref. to BIS code-BIS 9283-1979 with upto date amendements
106Type of enclosure of motor.-As per BIS-4691-1985(Latest)
107Type of duty :- Continous
108Mechanical output in KW-Suitable for driving submersible pumps required for duties specified against pumps.To avoid overloading of motor a margin of about 15-20% may be kept in the rated output to pime Mover
109Class of insulation-Class-B
110Max. Permissible temp. Rise of motor reqd. if different from that given in above.--To be quoted by tenderer
111Particulars of test reqd. & where they are to be conducted.-As per terms and conditions attached.
112Particulars as to whether voltage limiting device will be employed.-DOL star delta starter to be installed between bus bar and motor.Shunt capacitor is also proposed to be installed for improving the power factor at site. NOTE- Star delta starter upto 37.5 Kw
113Type of motor-As per BIS 9283-1979 or latest.
114Details of shaft extension required
115Break way torque in terms of rated load torque and the corresponding break-way starting current which may be taken from the supply with the starting apparatus in circuit. -Break way torque to be given by the tenderer but the starting current should not exceed 2.5 times of the full load current.
116Nature of load and any information regarding the driven machine which has a bearing upon the torque reqd. during the accelerated period, the kinetic energy of the moving parts to be accelerated and No. of starts during a specified period. -To work the pump offered.
117Where possible fault capacity of the system to which the motor is connected.-The motor should be able to withstand initial current of 2.5 times the rated current for two minutes without suffering damages or permanent deformations.
118PUMPS
119Nos. of pumps required.-1 No
120Spare parts required.-For two years normal maintenance as recommanded by manufacturer.
121Type of drive.-Electric induction motor
122Optional fittings required
123Pump Operating conditions
124Capacity -14.00 lps of one pump
125Total head in meters-66.49 mtrs.
126Static head -62.80 mtrs.
127Minimum depth of water-mtrs.
128Variation in water level-mtrs.
129Ground level to Max. water level (H.F.L)-mtrs.
130Ground level to delivery point-mtrs.
131Pressure in the suction tank.-mtrs.
132Pressure in the delivery tank-mtrs.
133Length of rising main-9.00 mtrs.
134Dia of rising main-150 mm
135Turbidity of water < than 50 ppm
136Drive type-Electric driven
137Limits of total head in which the pump is required to operate.(-) 15% to (+) 10% of total head.
138Suction/Delivery size of pump-To be specified by tenderer.
139Efficiency of pump at -To be specified by tenderer.
140a) Duty head
141b) (+) 10% head.
142c) (-) 15% head.
143Material of construction:to be specified by the tendrer(manufacturers certificate to be appended)
144Supply and fixing of fully automatic air breaker star delta Starter of Havella/L&T/BHEL make conforming to IS 13947-II latest with up to date amendments for Squirrel cage/Slipping motor mounted on panel with magnetic type overload release and Dashpot,Time lag,Under voltage release of suitable capacity,woth or wothout intial oil filling as the case may be with single phase preventor as per IS:1248 (P-V) 1983 with upto date amendments 1 No.
145Supply of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed (Almirah type) switch board comprising and capable of mounting the following accessories and with all internal electric connections, duly painted. The drawing of panel board shall be subject to approval of Engineer-in-Charge. 1 No.
146Providing & Fixing Ammeter AC supply, 100 mm square type auto electric of AE/ L&T Rishab make of suitable capacity for above motor with selector switches conforming to BIS-1248-1983 latest with upto date amendments. 1 No.
147Providing & Fixing Voltmeter AC supply, 100 mm square type auto electric AE/ L&T Rishab make of 0-500 Volts range for above motor with selector switches conforming to BIS-1248-1983 latest with upto date amendments. 1 No.
148ICTP switches with HRC fuses of Havells/L&T/standard /cromption make for required motor of suitable capacity and conforming to BIS: 4064-1978 latest with upto date amendments. 1 No.
149Bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutral conforming to BIS: 8084 –1976 and 11353-1985 read with 5578-1985 all latest with upto date amendmentsof suitable rating.. 1 No.
150MCB of suitable capacity of Havells/standard/MDS/Jyoti/Kilburn make to feed motors offered by the tenderer conforming to BIS: 2516-1985 latest with upto date amendments with neutral linked under voltage release. 1 No.
1513 phase indicator lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with up to date amendments of 15 watts.. 1 No.
15250 mm dial Hour run meter of CEE/NEE make of suitable range as per relevant BIS specifications. .1 No.
153Supply of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date amendments Baja/L&T/Asian/cromption make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of siemens/Gloster/ICC make form bus bar chamber to capacitor and also including L&T/LK/Kilburn make ICTP switches conforming to BIS –4064-1978 or latest with HRC fuses (range to be specified by the tendrerer).. 1 No.
154Providing and Fixing CI Sluice Valve PN-1.0 10.2Kg/cm² Kirloskar/Leader make i/c double flanged Sluice Valve Having Size one dia. Higher than Pump & capable of withstanding nominal seat pressure of 10.20 Kg/cm2 as per IS Code 14846:2000.. 1 No.
155Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable conforming to BIS 1554 (part-I) –1988 of latest with upto date amendments siemen/ closter/ICC make form meter of HPSEB- to MCB and form MCB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer. Supply Side:-Suitable Size Motor Side :-Suitable Size 6.00 Rmt
156Providing and Fixing Kirloskar/Leader make i/c double flanged (Swing Check Type) Reflux Valve Having Bypass Arrangement and Having Size one dia. Higher than Pump to delivery of Pump & capable of withstanding nominal seat pressure of 10.20 Kg/cm2 as per IS Code 5312-1984 (P-I). 1 No.
157Supply of PVC joint less flat water proof cable as per BIS: 694-1990 latest with upto date amendments suitable for the pump sets offered from MCB to motor including all other electrical equipment/accessories such as thimbles, flexible pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities it shall have to be replaced by Tender. 67.10 Rmt.
158Providing and laying double loop earthing with G.I. wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of required capacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and other electrical equipment’s. 1 Job.
159Supply of standard make circular dial pressure gauge 0-16 kg/cm2 range of feibig make with all accessories such as stop cock, copper tubing etc, conforming to BIS: 3624-1987 latest with upto date amendments. 1 No.
160Providing and laying delivery pipe 100 mm dia. GMS Tubes (Medium Class) (IS:1239 - 2004) jointed with MS flanges of table-5 as per IS: 6392-1971 (upto a length of 20 mtrs ) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses as per layout drawings approved by Engineer-in-Charge.(From Pump to Common header). 1 Rmt.
161Installation charges on all equipment including cost of tees, (Flow meter 1 Nos), bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge.1 Job
162Providing & fixing, Erection of electricity system in pump house (One Fan, One CFL outside & inside,One 5 Amp Socket inner side & outer side of pump house,One 16 amp Socket inner side of pump house.- 1 Job
163Providing & fixing M-Power MODULE,L&T make for mobile controller vide cat No.GSM 03010000 of reputed make conforming to standard with upto date with supply 160-500 v. AC-50 hz,single phase/three phase wire including cabling computed to delivery results in all respect and entire satisfaction of the Engineer in charge.
164Providing and fixing capacitor-15 KVR with moblie set including sims with message pack in all respect and entire satisfaction of the engineer in charge.
165Providing and fixing automatic pannel board MU-G40 of L&T make for 35HP Submersible Motors make manufactured by parental company comparising MNX contacts and MN relays,overload and single facing protection conforming to IS-13947-4IEC-60947-4 alongwith testing certificate including pushing button autostart,auto stop and restart facility,ICTP switches and all other electrical accessories which required for the job single phase preventor,3-phase indicator,time,relay selector cabiling to delivery results with all leads and lifts as per the direction of engineer in charge.
166Supply of Vertical submersible pumping set of KSB /BS/Johnstion/oswal/Crompton/Kirloskar/Calama make comprising to latest relevant BIS Code or any other make approved make by HPJSV. The pump should be fitted with bronze impeller of suitable alloys as per IS 8034-1976 latest suitable for Clear water having greased packed bearings and shaft with wound stator on motor side and with soft protection sleeve on pump side ensuring better life for shaft coupled to a submersible squirrel cage electric induction motor (water proof type) of required HP, RPM 2900 of reputed make conforming to BIS 9238-1979 latest with upto date amendments, totally dust and water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand non vertical loads with minimum wear and tear. It should also be fitted with a device to take up expansion of water with the heating of motor. The pump set should include all items containing item no. 74.01 & 74.78, water level guards, erection clamps , cable clips and depth gauge etc. and suitable for operation on data given below:-
167SITE CONDITIONS:-
168Location of site:Babehar (2nd Stage)
169The altitude of place in which the motor is intended to work in ordinary service
170Humidity:- Humid during rainy season
171Nature of atmosphere:-Normal
172Detail of quality of water:- Clear water
173Water free from sand or not:-Free from sand
174Water corrosive or not:-Not corrosive
175Turbidity:-<50 ppm
176Any other information if required.
177OPERATING CONDITIONS
178Type of current:- AC. Three phase
179Operating frequency :-50 Hz.
180Rated voltage- 400(+/-) 10% volts.
181System of earthing if any to be adopted-Double loop earthing
182Speed of revolution-To be quoted by tenderer .
183Direction of rotation- to be quoted by tender
184No. of working hours per day:-20 hours
185The maximum temperature of cooling air and water in the place in which the pump set is intended to work in ordinary service:- Temprature of place to be 20°C to 42°C
186MOTOR-
187Ref. to BIS code-BIS 9283-1979 with upto date amendements
188Type of enclosure of motor.-As per BIS-4691-1985(Latest)
189Type of duty :- Continous
190Mechanical output in KW-Suitable for driving submersible pumps required for duties specified against pumps.To avoid overloading of motor a margin of about 15-20% may be kept in the rated output to pime Mover
191Class of insulation-Class-B
192Max. Permissible temp. Rise of motor reqd. if different from that given in above.--To be quoted by tenderer
193Particulars of test reqd. & where they are to be conducted.-As per terms and conditions attached.
194Particulars as to whether voltage limiting device will be employed.-DOL star delta starter to be installed between bus bar and motor.Shunt capacitor is also proposed to be installed for improving the power factor at site. NOTE- Star delta starter upto 37.5 Kw
195Type of motor-As per BIS 9283-1979 or latest.
196Details of shaft extension required
197Break way torque in terms of rated load torque and the corresponding break-way starting current which may be taken from the supply with the starting apparatus in circuit. -Break way torque to be given by the tenderer but the starting current should not exceed 2.5 times of the full load current.
198Nature of load and any information regarding the driven machine which has a bearing upon the torque reqd. during the accelerated period, the kinetic energy of the moving parts to be accelerated and No. of starts during a specified period. -To work the pump offered.
199Where possible fault capacity of the system to which the motor is connected.-The motor should be able to withstand initial current of 2.5 times the rated current for two minutes without suffering damages or permanent deformations.
200PUMPS
201Nos. of pumps required.-1 No
202Spare parts required.-For two years normal maintenance as recommanded by manufacturer.
203Type of drive.-Electric induction motor
204Optional fittings required
205Pump Operating conditions
206Capacity -14.00 lps of one pump
207Total head in meters-63.81 mtrs.
208Static head -52.70 mtrs.
209Minimum depth of water-mtrs.
210Variation in water level-mtrs.
211Ground level to Max. water level (H.F.L)-mtrs.
212Ground level to delivery point-mtrs.
213Pressure in the suction tank.-mtrs.
214Pressure in the delivery tank-mtrs.
215Length of rising main-1032.00 mtrs.
216Dia of rising main-150 mm
217Turbidity of water < than 50 ppm
218Drive type-Electric driven
219Limits of total head in which the pump is required to operate.(-) 15% to (+) 10% of total head.
220Suction/Delivery size of pump-To be specified by tenderer.
221Efficiency of pump at -To be specified by tenderer.
222a) Duty head
223b) (+) 10% head.
224c) (-) 15% head.
225Material of construction:to be specified by the tendrer(manufacturers certificate to be appended)
226Supply and fixing of fully automatic air breaker star delta Starter of Havella/L&T/BHEL make conforming to IS 13947-II latest with up to date amendments for Squirrel cage/Slipping motor mounted on panel with magnetic type overload release and Dashpot,Time lag,Under voltage release of suitable capacity,woth or wothout intial oil filling as the case may be with single phase preventor as per IS:1248 (P-V) 1983 with upto date amendments 1 No.
227Supply of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed (Almirah type) switch board comprising and capable of mounting the following accessories and with all internal electric connections, duly painted. The drawing of panel board shall be subject to approval of Engineer-in-Charge. 1 No.
228Providing & Fixing Ammeter AC supply, 100 mm square type auto electric of AE/ L&T Rishab make of suitable capacity for above motor with selector switches conforming to BIS-1248-1983 latest with upto date amendments. 1 No.
229Providing & Fixing Voltmeter AC supply, 100 mm square type auto electric AE/ L&T Rishab make of 0-500 Volts range for above motor with selector switches conforming to BIS-1248-1983 latest with upto date amendments. 1 No.
230ICTP switches with HRC fuses of Havells/L&T/standard /cromption make for required motor of suitable capacity and conforming to BIS: 4064-1978 latest with upto date amendments. 1 No.
231Bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutral conforming to BIS: 8084 –1976 and 11353-1985 read with 5578-1985 all latest with upto date amendmentsof suitable rating.. 1 No.
232MCB of suitable capacity of Havells/standard/MDS/Jyoti/Kilburn make to feed motors offered by the tenderer conforming to BIS: 2516-1985 latest with upto date amendments with neutral linked under voltage release. 1 No.
2333 phase indicator lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with up to date amendments of 15 watts.. 1 No.
23450 mm dial Hour run meter of CEE/NEE make of suitable range as per relevant BIS specifications. .1 No.
235Supply of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date amendments Baja/L&T/Asian/cromption make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of siemens/Gloster/ICC make form bus bar chamber to capacitor and also including L&T/LK/Kilburn make ICTP switches conforming to BIS –4064-1978 or latest with HRC fuses (range to be specified by the tendrerer).. 1 No.
236Providing and Fixing CI Sluice Valve PN-1.0 10.2Kg/cm² Kirloskar/Leader make i/c double flanged Sluice Valve Having Size one dia. Higher than Pump & capable of withstanding nominal seat pressure of 10.20 Kg/cm2 as per IS Code 14846:2000.. 1 No.
237Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable conforming to BIS 1554 (part-I) –1988 of latest with upto date amendments siemen/ closter/ICC make form meter of HPSEB- to MCB and form MCB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer. Supply Side:-Suitable Size Motor Side :-Suitable Size 12.00 Rmt
238Providing and Fixing Kirloskar/Leader make i/c double flanged (Swing Check Type) Reflux Valve Having Bypass Arrangement and Having Size one dia. Higher than Pump to delivery of Pump & capable of withstanding nominal seat pressure of 10.20 Kg/cm2 as per IS Code 5312-1984 (P-I). 1 No.
239Supply of PVC joint less flat water proof cable as per BIS: 694-1990 latest with upto date amendments suitable for the pump sets offered from MCB to motor including all other electrical equipment/accessories such as thimbles, flexible pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities it shall have to be replaced by Tender. 67.10 Rmt.
240Providing and laying double loop earthing with G.I. wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of required capacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and other electrical equipment’s. 1 Job.
241Supply of standard make circular dial pressure gauge 0-16 kg/cm2 range of feibig make with all accessories such as stop cock, copper tubing etc, conforming to BIS: 3624-1987 latest with upto date amendments. 1 No.
242Providing and laying delivery pipe 100 mm dia. GMS Tubes (Medium Class) (IS:1239 - 2004) jointed with MS flanges of table-5 as per IS: 6392-1971 (upto a length of 20 mtrs ) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses as per layout drawings approved by Engineer-in-Charge.(From Pump to Common header). 1 Rmt.
243Installation charges on all equipment including cost of tees, (Flow meter 1 Nos), bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge.1 Job
244Providing & fixing, Erection of electricity system in pump house (One Fan, One CFL outside & inside,One 5 Amp Socket inner side & outer side of pump house,One 16 amp Socket inner side of pump house.- 1 Job
245Providing & fixing M-Power MODULE,L&T make for mobile controller vide cat No.GSM 03010000 of reputed make conforming to standard with upto date with supply 160-500 v. AC-50 hz,single phase/three phase wire including cabling computed to delivery results in all respect and entire satisfaction of the Engineer in charge.
246Providing and fixing capacitor-15 KVR with moblie set including sims with message pack in all respect and entire satisfaction of the engineer in charge.
247Providing and fixing automatic pannel board MU-G40 of L&T make for 35HP Submersible Motors make manufactured by parental company comparising MNX contacts and MN relays,overload and single facing protection conforming to IS-13947-4IEC-60947-4 alongwith testing certificate including pushing button autostart,auto stop and restart facility,ICTP switches and all other electrical accessories which required for the job single phase preventor,3-phase indicator,time,relay selector cabiling to delivery results with all leads and lifts as per the direction of engineer in charge.
248Supply of Solar AC vertical Submersible pump of KSB/Calama/SU/Johnstion make comprising to relevant BIS Code.The pump should be fitted with bronze impleler of suitable alloys as per IS 8034-1976 latest suitable for clear water having greased packing bearings and shaft with with wound stator on motor side with soft protection sleeve on pump side ensuring better life for shaft coupled to a submersible squirrel cage electric induction motor (Water proof type) of required HP,RPM 2900 of reputed make confiming to BIS 9238-1979 latest with upto date amendments,totally dust and water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chmaber and grease packed lubricated bearings and provided stainless steel thrust bearing plate to with stand non vertical loads with minimum wear and tear.It should also be fitted with a device to take up expansion of water with the heating of motor.The pump set should include all items containing item no. 78.01 & 78.78, water level guards, erection clamps , cable clips and depth gauge etc. and suitable for operation on data given below:-
249SITE CONDITIONS:-
250Location of site:Babehar (Solar operated AC Pump)
251The altitude of place in which the motor is intended to work in ordinary service
252Humidity:- Humid during rainy season
253Nature of atmosphere:-Normal
254Detail of quality of water:- Clear water
255Water free from sand or not:-Free from sand
256Water corrosive or not:-Not corrosive
257Turbidity:-<50 ppm
258Any other information if required.
259OPERATING CONDITIONS
260Type of current:- AC. Three phase
261Operating frequency :-50 Hz.
262Rated voltage- 400(+/-) 10% volts.
263System of earthing if any to be adopted-Double loop earthing
264Speed of revolution-To be quoted by tenderer .
265Direction of rotation- to be quoted by tender
266No. of working hours per day:-20 hours
267The maximum temperature of cooling air and water in the place in which the pump set is intended to work in ordinary service:- Temprature of place to be 20°C to 42°C
268MOTOR-
269Ref. to BIS code-BIS 9283-1979 with upto date amendements
270Type of enclosure of motor.-As per BIS-4691-1985(Latest)
271Type of duty :- Continous
272Mechanical output in KW-Suitable for driving submersible pumps required for duties specified against pumps.To avoid overloading of motor a margin of about 15-20% may be kept in the rated output to pime Mover
273Class of insulation-Class-B
274Max. Permissible temp. Rise of motor reqd. if different from that given in above.--To be quoted by tenderer
275Particulars of test reqd. & where they are to be conducted.-As per terms and conditions attached.
276Particulars as to whether voltage limiting device will be employed.-DOL star delta starter to be installed between bus bar and motor.Shunt capacitor is also proposed to be installed for improving the power factor at site. NOTE- Star delta starter upto 37.5 Kw
277Type of motor-As per BIS 9283-1979 or latest.
278Details of shaft extension required
279Break way torque in terms of rated load torque and the corresponding break-way starting current which may be taken from the supply with the starting apparatus in circuit. -Break way torque to be given by the tenderer but the starting current should not exceed 2.5 times of the full load current.
280Nature of load and any information regarding the driven machine which has a bearing upon the torque reqd. during the accelerated period, the kinetic energy of the moving parts to be accelerated and No. of starts during a specified period. -To work the pump offered.
281Where possible fault capacity of the system to which the motor is connected.-The motor should be able to withstand initial current of 2.5 times the rated current for two minutes without suffering damages or permanent deformations.
282PUMPS
283Nos. of pumps required.-1 No
284Spare parts required.-For two years normal maintenance as recommanded by manufacturer.
285Type of drive.-Electric induction motor
286Optional fittings required
287Pump Operating conditions
288Capacity -2.00 lps of one pump
289Total head in meters-99.69 mtrs.
290Static head -93.15 mtrs.
291Minimum depth of water-mtrs.
292Variation in water level-mtrs.
293Ground level to Max. water level (H.F.L)-mtrs.
294Ground level to delivery point-mtrs.
295Pressure in the suction tank.-mtrs.
296Pressure in the delivery tank-mtrs.
297Length of rising main-15.00 mtrs.
298Dia of rising main-65 mm
299Turbidity of water < than 50 ppm
300Drive type-Electric driven
301Limits of total head in which the pump is required to operate.(-) 15% to (+) 10% of total head.
302Suction/Delivery size of pump-To be specified by tenderer.
303Efficiency of pump at -To be specified by tenderer.
304a) Duty head
305b) (+) 10% head.
306c) (-) 15% head.
307Material of construction:to be specified by the tendrer(manufacturers certificate to be appended)
308Supply and fixing of fully automatic air breaker star delta Starter of Havella/L&T/BHEL make conforming to IS 13947-II latest with up to date amendments for Squirrel cage/Slipping motor mounted on panel with magnetic type overload release and Dashpot,Time lag,Under voltage release of suitable capacity,woth or wothout intial oil filling as the case may be with single phase preventor as per IS:1248 (P-V) 1983 with upto date amendments 1 No.
309Supply of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed (Almirah type) switch board comprising and capable of mounting the following accessories and with all internal electric connections, duly painted. The drawing of panel board shall be subject to approval of Engineer-in-Charge. 1 No.
310Providing & Fixing Ammeter AC supply, 100 mm square type auto electric of AE/ L&T Rishab make of suitable capacity for above motor with selector switches conforming to BIS-1248-1983 latest with upto date amendments. 1 No.
311Providing & Fixing Voltmeter AC supply, 100 mm square type auto electric AE/ L&T Rishab make of 0-500 Volts range for above motor with selector switches conforming to BIS-1248-1983 latest with upto date amendments. 1 No.
312ICTP switches with HRC fuses of Havells/L&T/standard /cromption make for required motor of suitable capacity and conforming to BIS: 4064-1978 latest with upto date amendments. 1 No.
313Bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutral conforming to BIS: 8084 –1976 and 11353-1985 read with 5578-1985 all latest with upto date amendmentsof suitable rating.. 1 No.
314MCB of suitable capacity of Havells/standard/MDS/Jyoti/Kilburn make to feed motors offered by the tenderer conforming to BIS: 2516-1985 latest with upto date amendments with neutral linked under voltage release. 1 No.
3153 phase indicator lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with up to date amendments of 15 watts.. 1 No.
31650 mm dial Hour run meter of CEE/NEE make of suitable range as per relevant BIS specifications. .1 No.
317Supply of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date amendments Baja/L&T/Asian/cromption make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of siemens/Gloster/ICC make form bus bar chamber to capacitor and also including L&T/LK/Kilburn make ICTP switches conforming to BIS –4064-1978 or latest with HRC fuses (range to be specified by the tendrerer).. 1 No.
318Providing and Fixing CI Sluice Valve PN-1.0 10.2Kg/cm² Kirloskar/Leader make i/c double flanged Sluice Valve Having Size one dia. Higher than Pump & capable of withstanding nominal seat pressure of 10.20 Kg/cm2 as per IS Code 14846:2000.. 1 No.
319Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable conforming to BIS 1554 (part-I) –1988 of latest with upto date amendments siemen/ closter/ICC make form meter of HPSEB- to MCB and form MCB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer. Supply Side:-Suitable Size Motor Side :-Suitable Size 6.00 Rmt
320Providing and Fixing Kirloskar/Leader make i/c double flanged (Swing Check Type) Reflux Valve Having Bypass Arrangement and Having Size one dia. Higher than Pump to delivery of Pump & capable of withstanding nominal seat pressure of 10.20 Kg/cm2 as per IS Code 5312-1984 (P-I). 1 No.
321Supply of PVC joint less flat water proof cable as per BIS: 694-1990 latest with upto date amendments suitable for the pump sets offered from MCB to motor including all other electrical equipment/accessories such as thimbles, flexible pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities it shall have to be replaced by Tender. 95.10 Rmt.
322Providing and laying double loop earthing with G.I. wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of required capacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and other electrical equipment’s. 1 Job.
323Supply of standard make circular dial pressure gauge 0-16 kg/cm2 range of feibig make with all accessories such as stop cock, copper tubing etc, conforming to BIS: 3624-1987 latest with upto date amendments. 1 No.
324Providing and laying delivery pipe 100 mm dia. GMS Tubes (Medium Class) (IS:1239 - 2004) jointed with MS flanges of table-5 as per IS: 6392-1971 (upto a length of 20 mtrs ) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses as per layout drawings approved by Engineer-in-Charge.(From Pump to Common header). 1 Rmt.
325Installation charges on all equipment including cost of tees, (Flow meter 1 Nos), bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge.1 Job
326Providing & fixing, Erection of electricity system in pump house (One Fan, One CFL outside & inside,One 5 Amp Socket inner side & outer side of pump house,One 16 amp Socket inner side of pump house.-1 Job
327Providing & fixing M-Power MODULE,L&T make for mobile controller vide cat No.GSM 03010000 of reputed make conforming to standard with upto date with supply 160-500 v. AC-50 hz,single phase/three phase wire including cabling computed to delivery results in all respect and entire satisfaction of the Engineer in charge.
328Providing and fixing capacitor-15 KVR with moblie set including sims with message pack in all respect and entire satisfaction of the engineer in charge.
329Providing and fixing automatic pannel board MU-G40 of L&T make for 35HP Submersible Motors make manufactured by parental company comparising MNX contacts and MN relays,overload and single facing protection conforming to IS-13947-4IEC-60947-4 alongwith testing certificate including pushing button autostart,auto stop and restart facility,ICTP switches and all other electrical accessories which required for the job single phase preventor,3-phase indicator,time,relay selector cabiling to delivery results with all leads and lifts as per the direction of engineer in charge.
330Providing & Fixing of 63mm hydrant with Main or submain line inlcuding HDPE Riser 63mm Double Threaded P.N-10.0,63mm PP Ball Valve,Bend,Male Female Coupler Threaded P.N-10.0,Service Saddle P.N-10.0 and elbow bend with steel clamp complete in all respect and jointing by electrofusion process for disribution system with 63 mm Dia (as per requirement of main & submain Line) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
331Providing & Fixing of 63mm hydrant with Main or submain line inlcuding HDPE Riser 63mm Double Threaded P.N-10.0,63mm PP Ball Valve,Bend,Male Female Coupler Threaded P.N-10.0,Service Saddle P.N-10.0 and elbow bend with steel clamp complete in all respect and jointing by electrofusion process for disribution system with 75mm Dia (as per requirement of main & submain Line) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
332Providing & Fixing of 63mm hydrant with Main or submain line inlcuding HDPE Riser 63mm Double Threaded P.N-10.0,63mm PP Ball Valve,Bend,Male Female Coupler Threaded P.N-10.0,Service Saddle P.N-10.0 and elbow bend with steel clamp complete in all respect and jointing by electrofusion process for disribution system with 90 mm Dia (as per requirement of main & submain Line) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
333Providing & fixing Valve Box for hydrant Size 12\\" Box (Rectangular) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
334Restoration Charges for road crossing as per HPPWD Norms (RC-1) OL-31 to OL-32 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56295531
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 14-07-2026
Authority
Authority Name Himachal Pradesh Agriculture Development Society
Work Description Tender for Providing Subheads Lift Irrigation Components Including Distribution System At Twis Babehar Under Hpcdp (Phase-Ii) Project-Jica-Oda Phase-Ii At Village Babehar, G.P Babehar, Tehsil Ghanari, Distt. Una (H.P.)
Basic Detail
Tender No No. Agr. HMR. DPMU (G) (7) P-II 2025-26 Vol-I Tender File-648 Dt 03.07.2026
Bidding Type Tender
Location
City Una
State Himachal Pradesh
Key Dates
Publish Date 03 Jul 2026
Submission Date 14 Jul 2026
Open Date 14 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee 2000
EMD 1.05 Lakhs
Exemption Not Available
Document List
BidDocumentBabehar.pdf
BOQ_204355.xls
e21c64c5-982a-4bfa-8a6a-2ccf523029bb.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Jul 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
pdf

BidDocumentBabehar.pdf

xls

BOQ_204355.xls

html

e21c64c5-982a-4bfa-8a6a-2ccf523029bb.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders