Tourism Government Departments Closing in 6 days TDR #56295183

Tender For Development Beautification And Illumination Of Shree Gopal Ganapati Temple Prakara Enclosure And Elements At Farmagudi Ponda Goa

Issued by Government Departments · goa, Goa
Tender Value
12.51 Crore
Estimated cost
Bid Submission
16 Jul 2026
6 days left
EMD
25.02 Lakhs
Bank guarantee accepted
Document Fee
30000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
goa → Goa
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Development Beautification And Illumination Of Shree Gopal Ganapati Temple Prakara Enclosure And Elements At Farmagudi Ponda Goa

BOQ

Name of Work:-
Sl. No. Item Description
1CIVIL WORKS
2Demolishing dry bricks, pitching in floors drains etc., including stacking of serviceable and disposal of unserviceable material within 50 mts. lead.
3Demolishing cement concrete 1:3:6 or richer mix including disposal of material within 50 m lead.
4Demolishing laterite stone masonry in cement mortar including stacking of serviceable material & disposal of unserviceable material within 50 mts. lead.
5Demolishing R.C.C. work including stacking of steel bars & disposal of unserviceable within 50 mts. lead.
6Dismantling steelwork in built up sections in angles, tees, flats and channels including all gusset plates bolts, nuts, cutting dismembering and staking within 50 mts. Lead
7Dismantling the tile work in floors and roofs laid in cement including stacking of materials within 50 meters lead for thickness of tiles 10mm to 25mm.
8Dismantling G.I. sheets roofing including ridges, hips valleys and gutters etc. and stacking the material within 50 meters lead.
9Dismantling rolling shutters, top covers and shafts etc. for replacement of springs ball bearing complete and refixing the shutter after replacement of springs and ball bearing (cost of replacement parts excluded) including all labour and returning the unserviceable parts to the department complete.
10Clearing grass and removal of rubbish upto a distance of 50 m outside the periphery of the area
11Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in :All types of soil and Ordinary rock including all types of laterite rock, blasting prohibited
12Earthwork in excavation by mechanical means (hydraulic excavator)/manual means in foundation pipeline trenches drain (not exceeding 1.5 m in width or 10 sq.m. on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m.All types of soil and Ordinary rock including all types of laterite rock, blasting prohibited
13Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer.
14Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.
15Supplying and filling in plinth under floors, trenches including watering ramming consolidating, dressing, complete. Murrum
16Providing and constructing Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1 cement : 4 coarse sand) in foundation and basement.
17Laterite masonry in neatly dressed stones for 23 cms thick masonry walls in c.m. 1 : 4 (1 cement : 4 coarse sand in foundation upto plinth level. Extra for laterite masonry in all sizes in superstructure from floor I level upto floor V level.
18Exposed decorative laterite masonry using Patradevi stone of size as specified and laid as directed by architect in cement mortar 1:4 (1 cement : 4 coarse sand)
19For mouldings of one stone width i.e. (10cm-15cm) with use of normal 280/230 x 330 size stone. Paid extra above normal masonry paid in cu.mt.rate
20Providing & laying cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded granitic or basaltic stone aggregate. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in : All works upto plinth level
21Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: (b) In retaining walls , return walls(any thk) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping bed blocks, anchor blocks, plain window sills, fillets etc, upto floor five level.
22Providing and laying in position machine batched concrete (BMC), machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete work including pumping of concrete to the site of laying but excluding the cost of centering , shuttering, finishing and reinforcement including admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing the strength and durability as per the direction of the Engineer-in-charge. M30 grade of reinforced cement concrete by using 420kg of cement per cu.m. of concrete. All works upto floor V level. (RMC shall be permitted at no extra cost)
23Providing TMT steel reinforcement bars of (SAIL, TATA. VIZAG, JSW Steel Ltd.) ) (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member.
24Centering & shuttering including Strutting, Propping & removal of forms for :Foundations, Footings, Bases for columns
25Centering & shuttering including Strutting, Propping & removal of forms for :Vertical surfaces such as retaining walls, return walls, Partitions, walls (any thickness) including attached Pilasters, Buttresses, Plinth and string courses, Fillets and the like.
26Centering & shuttering including Strutting, Propping & removal of forms for :Columns, Piers, Pillars, Abutments, Posts and struts (square rectangle polygon in plan)
27Centering & shuttering including Strutting, Propping & removal of forms for :Sides and Soffits of beams, Beam Haunchings, Cantilever, Girders, bressumers and Lintels plinth beams not exceeding 1m in depth
28Centering & shuttering including Strutting, Propping & removal of forms for :Staircases (except spiral staircases) excluding landing
29Centering & shuttering including Strutting, Propping & removal of forms for :Arches, domes, vaults upto 6.00 span
30Centering & shuttering including Strutting, Propping & removal of forms for :Suspended floors, roofs landings, shelves & their supports
31Providing and laying gloss/mirror polish Mudgal/Sadarhalli / approved granite stone 19mm thick inlay upto size 200x200mm in flooring over 20mm thick base of cement mortar 1:4 laid over and jointed with cement slurry including rubbling complete as directed by the Engineer. Minimum rate of stone/sq.m is Rs.1700/-
32Providing and laying mirror polish Sadarhalli / approved granite slabs (temple white)19mm thick in cladding laid over 12 mm (average ) thick neat cement paste/cement mortar 1:3 (1 cement : 3 sand ) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including required adhesive etc as directed by the Engineer.Minimum rate of stone/sq.m is Rs.1700/-
33Providing, fixing mirror polish skirting with Sadarhalli/ Mudgal / approved granite stone slab 19 mm thick (average) 150mm wide over 12 mm thick neat cement paste/ cement mortar 1:3 including required adhesive etc. complete as directed by the Engineer. Minimum rate of stone/sq.m is Rs.1700/-
34Making half moulding/ rounding for edges in flooring,counters including rubbing/ polishing etc. complete as directed by engineer
35Making full moulding/ rounding for edges in flooring, counters, cladding including rubbing/ polishing etc. complete as directed by engineer.
36Providing & fixing granite stone slabs (flamed finish) 18mm thk. in risers of steps, skirting, dado and pillars laid on cement paste & joint with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing & polishing complete. (a) Jet Black
37Providing and laying gloss / mirror polish Sadarhalli /Mudgal or approved granite patti/ border (temple white)19mm thick in flooring upto width 300mm over 20mm thick base of cement mortar 1:4 laid over and jointed with cement slurry including rubbing complete as per direction of the Engineer. Minimum rate of stone/sq.m is Rs.1700/-
38Providing Red Agra stone flooring 30mm thicness (avg.)on 20mm thick base of cement mortar 1:4(1 cement : 4 coarse sand) jointed with grey cement slurry mixed with pigment to match the shade of the tile including rubbing & polishing complete.
39Providing and laying in design & pattern factory made chamfered edge Cement Concrete paver blocks ( C. C. paver blocks) of M35/M40 strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of fine sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with river/manufactured sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath, parks, lawns, drive ways or light traffic parking etc. complete as per manufacturer’s specifications & direction of Engineer. 60mm thick with Yellow/ Orange/ Earth colour (M35 grade)
40Providing water proofing treatment over the new R.C.C. roofs terrace toilet by spreading cement slurry over the R.C.C. slab and laying of 10cms. Average laterite stone ballast coba with the necessary gradient for easy flow of rain water and the coba in covered with damp proof of approved make jointless water proofing plaster of mix 1:3 (1 cement: 3 find sand), finished smooth with wooden trowel with false marking of 30 cms square. The vertical surface of the adjoining walls are to be treated upto a height of 30cms including rounding of junction (the rate includes for complete items including labour and materials and including cost of initial treatment of roof slab as follows.The injunction of damp proof compound with cement solution will be given as and when found necessary for filling honey comb, cracks etc. in the R.C.C. slabs). NOTE: cement consumption 25kg/sq.m.
41Providing and constructing ferocement works for dome, shell roof & curved chajjas consisting of armature reinforcement, several meshes, high performance mortar placed in situ. The overall shell thickness will be 60 to 65 mm finished with cement plaster. Execution of main structural surfaces in situ and accessory brackets, ribs if any may be done precast and assembled. The shapes and curves shall be achieved as per architectural drawings. the work inclusive of scaffolding and form/mouldwork if any. Surface measurement on one side only and measurement curve.
42Providing and constructing ferocement works for elements having sharp corners, rounds, folds curves etc. consisting of armature reinforcement & mesh work (weld mesh or hexagonal mesh or both) as per shape, high performance mortar placed in situ. The overall shell thickness will be 60 to 65 mm finished with cement plaster or neat cement punning as desired by architect. Execution of elements either in precast or insitu as per site conditions/assembly details/ instruction by architect. The shapes and curves shall be achieved as per architectural drawings. The work inclusive of scaffolding and form/mouldwork if any. Surface measurement on all external sides and measurement along curve (Incase of post, balusters,railing top all sides exposed to atmosphere i.e one side of membrane to be computed).
43Providing and applying 6mm cement plaster to ceiling 1: 3 (1 cement : 3 fine sand).
44Providing and applying 12 mm thick 1:4 (1 cement : 4 fine sand) to walls, beams, etc. and all other vertical surfaces at all heights and leads.
4518mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge.
46Providing and applying white cement based putty of average thickness 1.00mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
47Wall painting (two or more coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade.
48Painting three or more coats with acryllic exterior paint of approved brand and manufacture (Such as Dulex/ Asian Paints/ Sherwin Willians) including applying one coat of cement primer and one coat of surface treatment etc. complete.
49GRANITE WORKS Cost of dressing of granite stone in two more lines, above which palamuna fine dressing /polish finishon all over the exposed faces of cornices and other embellishments as per the design supplied by the architect and as directed. The following rate includes the cost of skilled and unskilled craftsmen, cost of carving, cost of erection at site, cost of all necessary scaffolding material, chain pulley, cost of smithy materials as Tata fagot steel rods,charcoal,hammers etc including Supply of stone. Supply of granite stone includes cost of extraction, loading at prescribed quarry ,unloading at site and all transport charges including taxes levis, royalty etc Granite pillar 2840mm in height and 450mm wide in trunk composed of three pieces as per architectural drawing. Type of stone – Bangalore grey/temple grey/sadalhalli in general.Black granite wherever specifically mentioned in particular item. Decorations/moulds may be added at architects discretion. Assembly-with full stones & lesser components, preferably monolithic (architects instruction) TYPE A- Prakara & Extended Canopy Pillars. . Carving work on all sides with 10-15mm depth.Carving top surface mirror polished and all column visible surfaces mirror polishAll pieces to be joined by stone locks of 100X100X125mm. bottom base to be anchored by SS Rod 20mm dia casted 450mm in concrete & 450mm in granite by Eraldite.
50TYPE D- Half Cladding of Stage ColumnsHalf Cladding of columns with minimum 50 mm thick stone for 4.76 mt height with 450 x 150 mm thick stem and capital,base mouldings as per drawing. Carving top surface mirror polished and all column visible surfaces mirror polish.
51Khostam All external sides to be mirror polish & with decorative relief work
52Main Entrance Gateway - Frame Granite frame 5695mm in height and 900 mm side frame width with carvings as per architectural drawing. Carving all surfaces mirror polished.
53Main Entrance Gateway -Toran StambhaHalf granite columns of 5.70 mt height with 430 x 150 mm thick stem and capital,base mouldings as per drawing. Carving top surface mirror polished and all column visible surfaces mirror polish
54Main Entrance Gateway - PedestalGranite pedestal of 630mm in height with carvings/mouldings as per architectural drawing
55Providing anti – termite treatment to buildings conforming to I.S.S. 6113 part II 1971 (revised) including adopting precautions for health hazards and safety measures as required therein with the cost of all materials, chemicals, plants, equipments required for the treatment and furnishing a guarantee for a minimum period of 10 years from the date of completion including eradicating any infestation of termite free of cost during the guaranty period complete. (The payment will be made on plinth of the building ; Pre-construction
56Providing and applying elastomeric water proofing treatment on ferrocement shell / domes / curved chajja. Recommended technique : -a. Surface cleaningb. Widening & sealing of cracks ( if any ) by mixture of crack seal and bonding agent of Dr. Fixit.c. Application of raw URP bonding agent to surface under treatment.d. Application of cement slurry with bonding agent.e. Curing for 3 daysf. Application of base primer ' prime seal ' of Dr. Fixit in single coat.g. Application of elastomeric 'new coat' of Dr.Fixit in three coats with interval of 12 hours.Contractor to give warantee of 15 years against defects.
57Providing & laying 20mm thick Kota stone as drain cover over rainwater gutter without mortar with gap of 25mm
58Supplying and stacking of good earth at site including royalty and carriage upto 1 km. (earth measured in stacks will be reduced by 20% for payment).
591) Grassing with “doob” grass including watering and maintenance of the lawn for 30 days or more till the grass forms of thick lawn free from weeds and fit for moving, including supplying good earth if needed. (Cost of “doob” grass not included )3) In rows 5 cm apart in either direction
60Stainless steel Fabrication Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc.with hairline finish, including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
61Mild steel for Compound Gate Providing and fixing M.S. grill of required pattern for comppund gate etc with M.S. flats square or round bars with round headed bolts and nuts or by by screws. Ornamental grill
62ELECTRICAL WORKS
63Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface PVC conduit( medium) with modular switch, modular plates, suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C -- with Cat B Modular Accessories
64Wiring for group controlled light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface PVC conduit( medium) and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
65Supplying and fixing of following sizes of rigid PVC conduit alongwith accessories in surface(medium)/ recess(heavy) including cutting the wall and making good the same in case of recessed conduit as required.20 mm
6625 mm
67Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent surface steel conduit (medium) of appropriate size as required.2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm conduit)
682 x 4 sq.mm + 1 x 4 sq.mm earthwire (20mm conduit)
692 x 6 sq.mm + 1 x 6 sq.mm earthwire (25mm conduit)
70Supplying and fixing suitable size modular GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/ 6 A modular switch connection painting etc. as required.(a) Cat A
71Supplying and fixing suitable size modular GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 15/16 A and 5/6 A modular socket outlet modular socket outlet and 15/16 A modular switch connection painting etc. as required. (a) Cat A
72Supplying and Installing following size perforated type 16 SWG, M.S.cable tray of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required. 100mm width x 50mm depth
73150mm width x 50mm depth
74Supply of 3 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 3 x 2.5 sq.mm
753 x 4 sq.mm
76Supplying and fixing of suitable size GI box along with cover plate for 15 drivers for the LED fitting in recess etc
77Supplying and fixing following way SPN sheet steel MCB distribution board 240 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator) 8 way double door Cat B
78Supplying and fixing following way TPN sheet steel, single door, Verticle type MCB distribution board 415 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator) interconnection between incomer MCCB and busbars of following ways (but without MCBs as required)'(b) 8 way (8+24), single door, Vertical type,
79Supplying and fixing 6 A to 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. SP, Cat A
80DP, Cat A
81Supplying and fixing 40 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.TPN, Cat A
82Supplying and fixing 63 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.TP, Cat A
83TPN, Cat A
84Supply and errecting 300x 280 x 130 mm junction box for the fittings
85Supply of 4 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 4 Core 16 sq.mm
86Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 3 1/2 Core 35 sq.mm
87Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. (b) In rocky strata
88Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required.(b) In rocky strata
89Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. (2) 3 1/2 x 35 Sq. mm.
90Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. (5) 4 x 16 Sq. mm.
91Supply, installation, testing and commissioning of electronic type three phase energy meter (KWh), 4 wire, ISI marked, in polycarbonate or sgheet steel body ( base mounting type) with counter display/LCD display, with ELT, in Class 1.0, 50 Hz, 240 V. AC duly tested by MRT along with Test Certificates, complete as required of following capacity of make L & T only.(a) 5 to 20 A
92Earthing with GI earth pipe 2 mts long 40 mm dia medium class with ISI mark, of approved brands including accessories and providing masonry enclosure with CI/RCC cover having locking /Lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer- Incharge.The scope of work includes the following: a) Excavation of pit of size not less than 1.0x1.0x 2.0 mtrs(min) and disposal of excavated soil. b) Class B GI pipe, 40mm dia as per specifications. c) Charcoal /salt as per specs ( paid seperately). d) Refilling the pit of size not less than 1.0x1.0x 2.0 mtrs(min) with soft black soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe . g)watering arrangement(plumbing will be paid seperately).'(b) In rocky strata
93Extra for using salt and charcoal for pipe earth electrode as required( 65 Kgs of Charcoal and 5 Kgs of Salt).
94Providing and fixing 25 mm x 5 mm GI strip on surface or in recess for coneections etc. as required
95Supply, Installation, Testing and Commissioning of LED square/circular Max. 14 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1500 Lumens, min. efficacy of 110 lumen/W,CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD 0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. Make Wipro, Havells, Philips as required as directed by the Engineer in-charge.
96Providing and fixing ceiling mounted lights - 24w/22w with light temperature 4000k slim surface panel of Make Wipro/ Phillips/Havells on rcc ceiling inclusive of all acessories as required as directed by the Engineer in-charge.
97Supply, Installation, Testing and Commissioning of ceiling mounted lights - 2ft x 2 ft 40w with light temperature 4000k slim surface panel of make:- Wipro/ Phillips/Havells as required as directed by the Engineer in-charge approved on rcc ceiling inclusive of all acessories.
98Column UplighterProviding and fixing Ground mounted lights 6W/7W/10W with light temperature 2700k- IP66 rated ofmake Wipro/ Phillips/Havells as required as directed by the Engineer in-charge on rcc ceiling inclusive of all acessories.and custom made ground mounted stand of SS steel stand/mounting mechanism.
99Dome UplighterSupply, Installation, Testing and Commissioning of Ground mounted lights -100w/50 w with light temperature 2700k-IP 66 rated Flood light of make WIPRO/ Phillips/Havells as reuired as directed by the Engineer - in charge on rcc ceiling inclusive of all acessories.and custom made ground mounted stand of SS steel stand/mounting mechanism.
100Main Doorway UplighterProviding and fixing Ground mounted lights -50 w with light temperature 2700k-IP 65 rated Flood light of make Wipro /Phillips/Havells as required as directed by the Engineer in-charge in ground inclusive of all acessories.and custom made ground mounted stand of SS steel stand/mounting mechanism/Guard for safety of visitors.
101Kalasha UplighterProviding and fixing Ground mounted lights 20W/30 w with light temperature 2700k- make WIPRO /Phillips /Havells as required as directed by the Engineer in-charge on rcc ceiling inclusive of all acessories and custom made ground mounted stand of SS steel stand/mounting mechanism.
102Stage column UplighterProviding and fixing Ground mounted lights 20W/30 w with light temperature 2700k- 0f make WIPRO / Phillips /Havells as reqired as directed by the Engineer in- charge on rcc ceiling inclusive of all acessories and custom made ground mounted stand of SS steel stand/mounting mechanism.
103Murti UplighterProviding and fixing Ground mounted lights 6W/7W/10W with light temperature 2700k- IP66 rated of Wipro/ Phillips/Havells as requied as directed by the Engineer- incharge on rcc ceiling inclusive of all acessories.and custom made ground mounted stand of SS steel stand/mounting mechanism.
104Track light AssemblyProviding and fixing track mounted lights- 3 nos of 20W with light temperature 2700k- Wipro / Phillips /Havells as required as directed by the Engineer in-charge on 1 m track mounted on rcc ceiling inclusive of all acessories.
105Supply, Installation, Testing and Commissioning of 3 phase 30 KVA air cooled Voltage for input 340 to 470v three phase with Overvoltage/ under voltage cut-off, short circuit protection, Incomer and Outgoing MCB with manual bypass switch voltage stabilizer as above
106Supply, Installation, Testing and Commissioning of Indoor type Main panel fully compartmentalised, wall/floor mounted with frame of suitable M.S. channel duly painted fabricated of 14 swg CRCA sheets, the panel shall be of adequate size with a provision of 25% spare space to accomodate possible future switch gear, all MCCBs with roatary handles, completely derusted, chemically treated and powder coated for incomer cable having following as per drawing, Incomer 100A 4 pole microprocessor based MCC, 200A TPN Copper bus bar, RYB Lamp set, Digital multifunction meter with Ammeter, Voltmeter, KW tec with necessary CTs, ATS 100A 4 pole MCCB,Outgoing 4 set of 60A FP MCCB, 4 set of 30 A TPN MCB, Timer.
107Supply, Installation, Testing and Commissioning of 3KVA inveter, Single phase input and single phase output with short circuit protection, incomer and outgong MCBs with manual bypass switch with 4 hours backup, 150AH batteries Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56295183
AUTHORITY Government Departments
TENDER VALUE 12.51 Crore
LAST DATE 16-07-2026
Authority
Authority Name Goa Tourism Development Corporation Limited
Work Description Tender for Development Beautification And Illumination Of Shree Gopal Ganapati Temple Prakara Enclosure And Elements At Farmagudi Ponda Goa
Basic Detail
Tender No GTDC/PC/EE-(S)/2026-27/e-34
Bidding Type Tender
Location
City goa
State Goa
Key Dates
Publish Date 03 Jul 2026
Submission Date 16 Jul 2026
Open Date 17 Jul 2026
Finance
Tender Value 12.51 Crore
Tender Fee 30000
EMD 25.02 Lakhs
Exemption Not Available
Document List
b38d56e4-80ba-4447-be93-85bc8964b679.html
BOQ_30514.xls
Tendernotice_1 (11).pdf
Tendernotice_10.pdf
Tendernotice_11.pdf
Tendernotice_12.pdf
Tendernotice_13.pdf
Tendernotice_14.pdf
Tendernotice_15.pdf
Tendernotice_2 (4).pdf
Tendernotice_3 (1).pdf
Tendernotice_4.pdf
Tendernotice_5 (1).pdf
Tendernotice_6.pdf
Tendernotice_7.pdf
Tendernotice_8.pdf
Tendernotice_9.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Jul 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

b38d56e4-80ba-4447-be93-85bc8964b679.html

xls

BOQ_30514.xls

pdf

Tendernotice_1 (11).pdf

pdf

Tendernotice_10.pdf

pdf

Tendernotice_11.pdf

pdf

Tendernotice_12.pdf

pdf

Tendernotice_13.pdf

pdf

Tendernotice_14.pdf

pdf

Tendernotice_15.pdf

pdf

Tendernotice_2 (4).pdf

pdf

Tendernotice_3 (1).pdf

pdf

Tendernotice_4.pdf

pdf

Tendernotice_5 (1).pdf

pdf

Tendernotice_6.pdf

pdf

Tendernotice_7.pdf

pdf

Tendernotice_8.pdf

pdf

Tendernotice_9.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders