Agriculture Government Departments Closing in 34 days TDR #56291974

Tender For Construction Of Multi-Commodity Packhouse (Part A-Civil Work), Including Supply & Installation Of Vapour Heat Treatment (Vht) Unit With Integrated Packhouse And Irradiation Unit & Scientific Cold Storage Facilities (Part B - Plant & Machin

Issued by Government Departments · Thane, Maharashtra
Tender Value
127.61 Crore
Estimated cost
Bid Submission
07 Aug 2026
34 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
17700
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thane → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Multi-Commodity Packhouse (Part A-Civil Work), Including Supply & Installation Of Vapour Heat Treatment (Vht) Unit With Integrated Packhouse And Irradiation Unit & Scientific Cold Storage Facilities (Part B - Plant & Machinery) At Bapgaon (Thane)

BOQ

Name of Work:- Construction of Multi-Commodity Packhouse (Part A-Civil work), including Supply & installation of Vapour Heat Treatment (VHT) unit with Integrated Packhouse and Irradiation Unit & scientific cold storage facilities (Part B – Plant & Machinery) at Bapgaon (Thane)
Sl. No. Item Description
1PART A Civil works (1.001 to 1.201)
2Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 milimeter, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 milimeter in thickness.
3Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50 meter and spreading for embankment or stacking as directed. By Manual Means. ( Item used only when Quantity is below 10 Cubic meter)
4Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum moisture content, carriage of mixed Material to work site, spreading in uniform layers with motor grader / Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - II Material
5Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2 milimeter Aggregate)
6Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means - Grading II (Using Screening Type B (11.2 milimeter Aggregate)
7Providing and applying tack coat on the prepared surface heating by fames in Boiler and spraying bitumen set footed in bitumen boller on B.T. surface 2.5 Kilogram/10 square meter (Viscosity Grade-30 bulk bitumen rates are considered to arrive at rates)
8Providing and constructing 75 milimeter. thick Modified Penetration Macadam (MPM) road surface including all materials, preparing the existing road surface, spreading 40 milimeter. stone metal layers 30% crusher broken metal + 70% Hand broken (by breaking rubble obtained by blasting) heating and spraying the bitumen of specified grade @ 2 Kilogram/square meter , spreading 12 milimeter size chips compacting with three wheel static roller having weight 8 to 10 Metric Tonne to achive the desired degree of compaction as per Technical Specification Clause 506 etc. complete. Including picking of existing Water bound Macadam surface. (Viscosity Grade-30 bulk bitumen rates are considered to arrive at rates)
9BITUMINOUS MACADAM:--Providing and laying bituminous macadam using crushed aggregate of Grading 1, premixed with bituminous binder, transported at site with Vehicle Tracking System (VTS), laid over a previously prepared surface , finished to the required grade ,level, alignment,and rolling to achieve the desired density for 80/100 milimeter compacted thickness with drum mix type hot mix plant with Supervisory Control and Data Acquisition (SCADA) having complying essential features of Hot mix plant as per Indian Roads Congress (IRC) -27 2009 specified conditions and attachments such as electronic load sensor based belt conveyers,automatic synchronization of bitumen and aggregate fedder,built in dust controller system and Programmable Logic Controller (PLC) for Drum Mix plant ,Sensor paver,and Vibratory roller excluding prime/Tack coat etc. complete --Bitumen 3.30% of specified grade (Viscosity Grade-30 bulk bitumen rates are considered to arrive at rates)
10BITUMINOUS CONCRETE:--Providing and laying bituminous concrete using crushed aggregate of grading 1, premixed with bituminous binder @5.40% by weight of total mix and filler, transported at site with Vehicle Tracking system (VTS), laid over a previously prepared surface, finished to the required grade ,level, alignment, and rolling to achieve the desired density for 50 milimeter compacted thickness with drum mix plant with Supervisory Control and Data Acquisition (SCADA), Sensor paver and Vibratory roller excluding prime/Tack coat etc. complete --Bitumen of specified grade with stone dust filler. (Viscosity Grade-30 bulk bitumen rates are considered to arrive at rates)
11Providing and laying 125 micron Low Density Polyethylene (LDPE.) sheet confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.
12Providing and fixing factory made Hydraulically pressed Mechanically vibrated and compacted precast inter locking cement concrete paving blocks 80 milimeter thick in Mix 40 grade of approved size and shape for City streets, small /medium market roads,low volume roads, utility cuts on arterial roads etc. as specified and as per Indian Standard 15658:2006 including cost of all materials, manufacturing, curing, transportation of blocks to work site including loading, unloading and stacking as directed, laying paving blocks in position over prepared bed of natural sand / crushed sand of 50 milimeter thickness including necessary excavation in all stratas, spreading blindge of fine sand over the prepared bed, compacting blocks by plate vibrator etc. complete.
13Providing and laying cement concrete pipe of Indian Standard 458:2003 Non-Pressure (NP)-2 class of 450 milimeter diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
14Providing and laying cement concrete pipe of Indian Standard 458:2003 Non-Pressure (NP)-2 class of 900 milimeter diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
15Providing and laying cement concrete pipe of Indian Standard 458:2003Non-Pressure (NP)-2 class of 1200 milimeter diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
16Dewatering on Brake Horsepower basis by using water pump including diversion of stream, providing cofferdams, earthern bunds etc. as may be necessary for foundation and other parts of the the works and pumping out water during and after excavation as may be required by using 3.0 Brake Horsepower (BHP) pump etc. complete. (prior approval of Superintending Engineer will benecessary)
17Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 meter beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling,ramming watering including shoring and strutting etc. complete. (Lift upto 0.00 to 1.50 meter) By Manual Means
18Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 meter beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling,ramming watering including shoring and strutting etc. complete. (Lift upto 0.00 to 1.50 meter) By Manual Means
19Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 meter beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling,ramming watering including shoring and strutting etc. complete. (Lift upto 1.5 to 3 meter) By Manual Means
20Excavation for foundation in Hard murum and boulders including removing the excavated material upto a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling,ramming watering including shoring and strutting etc. complete. (Lift from 3.00 meter to 4.50 meter) By Mechanical Means
21Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramilimetering ,watering including shoring and strutting etc. complete. (Lift from 3.0 meter To 4.50 meter) By Mechanical Means
22Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etc. including trimilimetering and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramilimetering etc. complete. By Mechanical Means
23Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper.
24Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per One Square Metre of surface area covering ten years guarantee on bond paper.
25Filling in plinth and floors with approved excavated material in 15 centimeter to 20 centimeter Layers including watering and compacting etc. complete.
26Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 centi meter to 20 centi meter including watering and compaction etc. complete.
27Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 centimeter (cm) to 20 centimeter thick including hand packing and compacting etc. complete.
28Providing soling using 80 milimeter size trap metal in 15 centimeter layer including filling voids with Crushed sand/grit,ramming watering etc. complete.
29Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.
30Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete.
31Providing and laying Cast in situ/Ready Mix cement concrete in Mix 15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition (PLC with SCADA) enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical Shaft Impactor (VSI) Grade)
32Providing and laying Cast in situ/Ready Mix cement concrete Mix 30 of trap / granite/quartzite/ gneiss metal for Reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced cement concrete columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including Steel centering formwork, cover blocks laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition (PLC with SCADA) enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical Shaft Impactor Grade)
33Providing and laying Cast in situ/Ready Mix cement concrete Mix 30 of trap / granite /quartzite/ gneiss metal for Reinforced cement concrete columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition (PLC with SCADA) enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical Shaft Impactor Grade)
34Providing and laying Cast in situ/Ready Mix cement concrete in Mix 30 of trap/ granite/ quartzite/ gneiss metal for Reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition (PLC with SCADA) enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical Shaft Impactor Grade)
35Providing and laying Cast in situ/Ready Mix cement concrete Mix 30 of trap/ granite / quartzite/ gneiss metal for Reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition (PLC with SCADA) enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical Shaft Impactor Grade)
36Providing and laying Cast in situ/Ready Mixcement concrete Mix 25 of trap metal for Reinforced cement concrete chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition (PLC with SCADA) enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical Shaft Impactor Grade)
37Providing and laying Cast in situ/Ready Mix cement concrete Mix 25 of trap metal for Reinforced cement concrete canopy as per detailed designs and drawings including steel centering, formwork, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing etc. complete (excluding reinforcement). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition (PLC with SCADA) enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical Shaft Impactor Grade)
38Providing and laying Cast in situ/Ready Mix cement concrete in Mix 25 of trap/ granite/ quartzite/ gneiss metal for Reinforced cement concrete pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition (PLC with SCADA) enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical Shaft Impactor Grade)
39Providing and laying Cast in situ/Ready Mix cement concrete in Mix 25 of trap gneiss metal for Reinforced cement concrete Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with Cement Mortor 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition (PLC with SCADA) enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical Shaft Impactor Grade)
40Providing and fixing in position Thermo-Mechanically Treated Iron bars, (TMT - FE) - 500 bar reinforcement of various diameters for Reinforced cement concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
41Providing and fixing in position High Corrosion Resistant Material (HCRM)/ Corrosion Resistant Steel(CRS) bar reinforcement of various diameters for Reinforced cement concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
42Providing second class Burnt Brick masonry with conventional/ Indian Standard type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete.
43Providing second class Burnt Brick masonry with conventional/ Indian Standard type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete
44Providing Autoclaved Aerated Concrete Block masonary of conforming to Indian Standard: 2185 (Part 3) - 1984 in extra fine jointing mortar of fix block of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to Indian Standard :6441 (Part I) - 1972)
45Providing Autoclaved Aerated Concrete Block masonary of conforming to Indian Standard: 2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in Half brick thick wall including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to Indian Standard:6441 (Part I) - 1972)
46Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth of external walls including bailing out water manually , striking joints on un exposed faces and watering etc.complete.
47Providing expansion joints in Reinforced cement concrete framed structure (interior column) with plain premoulded filler 25 milimeter (mm) thick including fixing Teak Wood battens on both faces and finishing as directed etc. Complete.
48Providing expansion joints in Reinforced cement concrete framed structure (exterior Columns) with plain premoulded filler 25 milimeter thick and 3 milimeter thick alluminium plate, hold fast, fixing Teak Wood battens on internal face, finishing etc. complete as directed.
49Providing expansion joints in Reinforced cement concrete framed structure (at floor level) with premoulded filler 25 milimeter thick and 3 milimeter thick aluminium plate as required, bitumen poured filler and fixing Teak Wood battens on rear faces etc. complete as directed.
50Providing expansion joints in Reinforced cement concrete framed structure (at terrace level) with premoulded filler 25 milimeter thick and 3 milimeter thick aluminium plate as required, bituminous poured filler, fixing lead, flashing on upper side and Teak Wood battens on inner face finishing etc. Complete as directed.
51Providing and fixing bituminous pad 25 milimeter thick for expansion joints in retaining wall, compound wall etc. complete.
52Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 Square Metre /Kilogram with two coat using approved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete.
53Providing water proofing in Water closet and bath including brick bat cobain all position including providing and laying 12 milimeter bed ding in cement mortor 1:3 on verg in concrete slab with water proofing compound @ 1 Kilogram /per bag of cement laying brick bat coba of required thickness in cement mortor 1:5 with water proofing compound 1 Kilogram /bag of cement grouting and finishing the top layer with 20 milimeter thick brick bedding in cement mortor 1:3 with water proofing compound 1 Kilogram /per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years guarantee on requisite stamp paper including curing etc. complete.
54Providing and fixing 20 to 25 milimeter thick rough shahabad box type water proofing treatment to vertica out side faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 milimeter between rough shaha bad and Reinforced cement concrete walls with cement grout mixed with water proofing liquid Algae proof or other a like with one tile lift method, brushing the joints horizontally with cements lurry mixed with water proofing liquid for width 30 to 35 milimeter and sloping coping over top most tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofingl iquid,curing,with 7 years guarantee on court feest amp of Rs.100/-with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete)
55Providing and applying required coats of a water based Evercrete Deep Penetrating Sealer (DPS) on cement concrete surface like roads,beams,and columns,plastered walls,basements, roofs, potable water tanks etc to react with cement and to penetrate concrete structure there by making it resistant to chemicals /chlorides water to make it dust proof and to act as a water resistant at the same time which Strengthens the treated surface and reduce the curing period etc complete.
56Providing internal cement plaster 6 milimeter thick in a single coat in cement mortar 1:3 with out neeru finish to concrete surface in all positions including scaffolding and curing etc. complete.
57Providing internal cement plaster 12 milimeter. Thick in Single coats in cement mortar 1:3 with out neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete.
58Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 milimeter thick in cement mortar 1:4 using waterproofing compound at 1 Kilogram per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 milimeter thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.
59Providing tuck pointing with cement mortar 1:3 for stone/Brick masonry including scaffolding and curing etc. complete.
60Providing fine cement finish 1.5 milimeter thick over green plaster surface including scaffolding curing etc. complete.
61Providing and fixing chicken mesh of 22 gauge, with about 30 centimeter width at the junction of Reinforecd cement concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /Burnt brick masonry and or tying by binding wire etc. complete
62Providing and applying plaster with plaster of paris in 6 milimeter thickness to previously plaster surface in all position including preparing the surface scaffolding etc. complete.
63Providing and laying in situ cement concrete Mix 20 with tremix treatment for 100 milimeter thickness for flooring with groove cutting of 4 milimeter wide and 20 milimeter deep with necessary refilling with bitumen etc. complete.
64Providing and laying in situ cement concrete Mix 30 with tremix treatment for 200 milimeter thickness for flooring with groove cutting of 4 milimeter wide and 20 milimeter deep with necessary refilling with bitumen etc. complete.
65Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 milimeter to 20 milimeter thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement Mortor 1:3 curing and cleaning etc. complete.
66Providing and fixing machine cut machine polished 18 milimeter to 20 milimeter thick telephone black /Amba White /Catbary brown /RBI red /Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.
67Providing and fixing machine cut mirror polished 18 milimeter to 20 milimeter thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete . Both side polish
68Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 milimeter to 605 milimeter x 590 milimeter to 605 milimeter of 8 to 10 milimeter thickness and confirming to Indian Standard 15622-2006 (group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete.
69Providing and laying vitrified rustic matt stone finish tiles having size 590 milimeter to 605 milimeter x 590 milimeter to 605 milimeter of 8 to 10 milimeter thickness and confirming to Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete.
70Providing and laying vitrified rustic matt stone finish tiles having size 590 milimeter to 605 milimeter x 590 milimeter to 605 milimeter to 8 to 10 milimeter thickness and confirming to Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning. etc. complete.
71Providing and fixing heavy duty inter locking concrete Coloured paving blocks of 80 milimeter thickness of having a strength of 300 Kilogram/Square centimeter of approved quality and shape on a bed of crushed sand of 25 to 30 milimeter thick including skirting joints and cleaning etc. complete
72Providing and laying Vitrified RUSTIC MATT STONE finish having decorative type tiles of size 600 millimeter x 600 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical and confirming to Indian Standard 15622-2006 (Group Bla) of approved make shade and pattern for flooring in required position laid on a bed of bonding chemical filling joints curing and cleaning etc. complete.
73Providing and laying Vitrified STONE EFFECT FINISH having decorative type tiles of size 590 millimeter to 605 millimeter x 590 millimeter to 605 millimeter of 8 to 10 millimeter thickness (on a Dado And Skirting ) with bonding chemical and confirming to Indian Standard 15622-2006 (Group Bla) of approved make shade and pattern for flooring in required position laid on a bed of bonding chemical filling joints curing and cleaning etc. complete.
74Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 milimeter thick for door frame/ dado/ window boxing etc. On Cement Mortor 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete.
75Providing and laying polished hand cut Kotah Stone flooring 25 milimeter to 30 milimeter thick and 45 centi meter to 55 centimeter wide in plain/diamond pattern on a bed of 1:6 Cement Mortor including cement float, filling joints with neat cement slurry, curing, polishing and cleaning complete.
76Providing and applying Royale Luxury Emulsion of approved make on internal wall surface as detailed below Scrapping for surface with emery paper and wipe clean for area. wall primer with brush by adding mineral turpentine oil by 8 to 10 % or water by 15 to 20% allowing to dry for 6 to 8 hours. After applying acrylic wall putty with appropriate prpportion of water of allow to dry for period of 4 to 6 hours of activity. Scrapping with emery paper and wipe clean Applying paints Royale Luxury emulsion 1st coat with brush water content water 40 to 45% or 65 to 70% by role Applying paints Royale luxury emulsion 2nd coat with brush with water content 40 to 45% or 65 to 70 % by roller. (With prior approval of Superitending Engineer.)
77Providing and fixing 3.5 to 4 milimeter thick Veneer finish wall Panaling made out of 50 x 25 milimeter (finished size) Country cut teak Wood (C.C.T.W.) frame work or size of 600 x 600 milimeter center or as per site condition covered by 6 milimeter thick marine plywood of the generally confiriming to Indian Standard 710-1980 finished with 3.5 to 4 milimeter thick matching Veneer of approved color and in satin wallnut groov matched veneer pattern and design including melamine polishing & design with antitermite treatment etc. to plywood and woodwork with ten years guarantee bond etc. including all lead and lifts complete as per Architects Drawing and instructions of Engineer Incharge.
78Providing and fixing colour coated Zincalume ( R ) Aluminum-Zinc coating (AZ) 150 ( Minimum 150 grams/square meter total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 milimeter Base Metal Thickness (BMT) (0.5 milimeter Total Coating Thickness), Hi-strength steel with minimum 550 Megapascal (MPa) yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 µm, comprising of nominal 25 µmexterior coat on top surface and nominal 10 µm (10 micrometers or 10 microns) reverse coat on back surface. Profile sheet shall have nom. 950-1050 milimeter effective cover width and nominal 25-30 milimeter deep ribs with subtle square fluting in the five pan at nominal 180-250 milimeter center- to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with minimum 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/ One Square Metre)
79Providing and fixing Unplasticized Polyvinyl Chloride (UPVC) Roof made up of 3 layers roofing material of thickness 2 milimeter having width of 1130 milimeter and of required Length having Tensile strength not less than 330 Kilogram/centimeter ², including fastening with self drilling screw having washers made of stainless steel etc. complete.
80Providing and fixing Polyvinyl Chloride coloured Ridge tiles over Unplasticized Polyvinyl Chloride roofing where required having size 113 centimeter x 41 centimeter for ridge including fastening with self drilling screw having washers made of stainless steel etc. complete.
81Providing and fixing frame with / without ventilator of size as specified with Country cut teakwood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300 milimeter x 40 milimeter x 5 milimeter with oil painting, etc. complete
82Providing and fixing solid core flush door shutter in single leaf 32 milimeter thick decorative type of exterior grade as per detailed drawings approved face veneers 3 milimeter thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete.
83Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 milimeter with lock plate of 3.15 milimeter thickness reinforced with 35 x 35 x 5 milimeter angle section fitted with sliding bolts and handles for both sides, deep Mild steel channel section of depth and thickness not less than 65 milimeter and 3.15 milimeter respectively with hold fast arrangements, Mild steel Bracket plate 300 x 300 x 3.15 milimeter minimum size and shape with square bar, suspension shaft of minimum 32 milimeter diameter, hood cover of Mild steel sheet not less than 0.9 milimeter thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (Indian Standard 62481979) (With mechanical gear)
84Providing and fixing collapsible steel gate in one /two leaves with hotrolled vertical channels of 18 x 9x3 milimeter minimum size,crossing of Mild steel flats of size 18 x 5 milimeter Tor Esection for runner of minimum 40 x 6 milimeter size for flange, Mild steel flat for to prunner of minimum size 40 x 12 milimeter with roller wheels confirming to grade Flake Graphite Cast Iron (F.G.) 150 fitted with snapheade drivets of minimum size 6 milimeter max.spacing of vertical channels be 100 milimeter enclosed gate position and clear space of 150 milimeter between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer and oil painting etc. complete. (Indian Standard 105211983).
85Providing and fixing fiber glass reinforced polyster door shutter 30 milimeter thick as per Indian standard 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc complete
86Providng and fixing in position anodised extruded aluminum partitions, partly glazed and partly laminated having frame made out of extruded tubular section of size 40 milimeter x 60 milimeter with 12 milimeter thick three layered flat pressed teak wood particle board bonded with boiled water proof (BWP) type exterior grade phenol formaldehyde synthetic resin conforming to Indian standard 128231990, laminated on both sides, Novateakor equivalent and 5 milimeter thick selected quality plain/ float glass panels fixed with aluminum glass clips 12 milimeter x 12 milimeter and rubber cushioning beading to glass partitions as per approved drawing etc. compete
87Providing and fixing welded mesh of 11 gauge wires having mesh size 50 milimeter x 25 milimeter including Mild steel angle frame of size 35 milimeter x 35 milimeter x5 milimeter in position with oil painting 3 coats etc. complete
88Providing and fixing solid core flush door shutter in single leaf 32 milimeter thick decorative type of exterior grade as per detailed drawings approved face veneers 3 milimeter thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete.
89Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.
90Providing and fixing mild steel grill work for windows, ventilators, etc. 15 Kilogram/ One Square Metre as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete.
91Providing and fixing 40 milimeter diameter and 1.5 milimeter thick Stainless steel hand railing in Stainless steel 304 Grade including fabricating ,fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. complete
92Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 milimeter dia. and vertical pipe of 38 milimeter dia at 0.60 m c/c or as required and horizontal pipes of 25 milimeter dia in three rows, all pipes of 2 milimeter thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 milimeter dia above newel post of 75 milimeter diameter etc. complete (Prior approval of sample and brand by Execuative Engineer is necessary before use)
93Providing and fixing 50 milimeter dia meter water meter with non-return valve including strainer, sockets /union nut and including water meter box making locking arrangement and lock. [without chamber]
94Providing and fixing 15 milimeter dia. Screw down bib /stop tap of brass including necessary socket union nut complete.
95Providing and fixing 25 milimeter dia. Screw down bib / stop tap of brass including necessary socket union nut complete.
96Providing and fixing screw down 15 milimeter dia. Wheeled stop tap of brass including necessary sockets/union nut complete
97Providing and fixing screw down for 25 milimeter dia. Wheeled stop tap of brass including necessary sockets /union nut complete.
98Providing and fixing screw down for 50 milimeter dia. Wheeled stop tap of brass including necessary sockets/ union nut complete.
99Providing and fixing push cock (Self closing tap) symet type of 15 milimeter dia.including necessary socket, testing etc. complete.
100Providing and fixing 45 centimeter wide mild steel ladder of 40 milimeter x 6 milimeter mild steel flat stringers and steps of 18 milimeter dia. mild steel bar for water tank including fixing it in (1:2:4) Mix 15 cement concrete block 60 centimeter x 30 centimeter x 30 centimeter and painting the ladder complete. (Anti Corossive Paint)
101Providing and fixing white glazed earthen ware Wash Hand Basin of 55 centimeter. x 40 centimeter size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connections including polyvinyl chloride waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete.
102Providing and fixing 10 centimeter Cast iron Nahani Trap including Cast iron grating bend and piece of Cast iron pipe upto the outside face of the wall complete.
103Providing and fixing 15 centimeter x 10 centimeter salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.
104Providing and laying for 225 milimeter diameter salt glazed stoneware pipe including fittings Such as bends, tees, single junction, double junctions laying, jointing (including excavation and refilling the trenches) complete.
105Providing and laying concrete pipes of Indian standard Non pressure class of 150 mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete..
106Providing and constructing Brick Masonry Inspection Chamber 90 centimeter x 45 centimeter With Reinforced cement concrete raft in Black cotton soil area including cost of reinforcement, 1:2:4 cement concrete channel shalf round Salt Glazed Stoneware pipes, Brick Masonry, plastering from inside and air tight with 75 milimeter thick Reinforced cement concrete cover medium duty 140 Kilogram etc. complete.
107Providing and fixing 450 milimeter x 550 milimeter size superior type Belgium mirror with 16 milimeter dia. nickel plated towel rod etc. complete.
108Providing and fixing chromium plated towel rod 16 milimeter dia and 75 centimeter in length including all accessories complete.
109Providing and fixing European type white glazed earthenware coupled closet symphonic trap with symphonic low level white glazed 10 litres cistern with black backlite seat with all necessary pipe connection etc. complete.
110Providing and fixing Indian standards institution 1729/2002 grade 100 milimeter dia Cast Iron Soil Pipes With lugs including plug bend necessary fittings such as bends, tees, single junction, double junction, slottedvent, off sets on wall orinto the ground including filling joints with cement mortar 1:2 proportion fixing on wall by means of galvanised Mild Steel bracket of 30 x 5 milimeter plate and 8 milimeter square rod with Galvanised Iron clamp with wash erasper design, drawing and as directed to keep pipe 50 milimeter away from wall including necessary scaffolding and painting the exposed faces with one coat of red lead oil paint and two coats of white oil paint including removing the existing pipe if necessary and conveying and stacking in PWD Chowky or as directed by Engineer-in-Charge.
111Providing and fixing 100 milimeter dia stabiliser pipe/ Polyvinyl Chloride soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.
112Providing and fixing High-Density Polyethylene. container one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet,outlet overflow pipe inclusive of all tanks capacity between 200 to 1000 liters
113Providing and fixing on walls/ ceiling /floor 15 milimeter dia. Chlorinated Polyvinyl Chloride pipe (CPVC) with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stackingt he same in PWD chowky or as directed etc. Complete
114Providing and fixing on walls/ ceiling /floor 25 milimeter dia. Chlorinated Polyvinyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipeline if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete.
115Providing and fixing on walls /ceiling /floor 50 milimeter dia. Chlorinated Polyvinyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete.
116Providing and fixing Polyvinyl Chloride Rain water pipes of 160milimeter outer diameter and having wall thickness of 2.2 to 2.7 milimeter confirming to Indian Standard 13592-1992 including proper rainwater receiving recess with Polyvinyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 milimeter to 40 milimeter from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on Cement Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 years for any leakages or dislocations of pipes. All thePolyvinyl Chloridefittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.
117Providing and fixing Polyvinyl Chloride Rain water pipes of 110milimeter outer diameter and having wall thickness of 2.2 to 2.7 milimeter confirming to Indian Standard 13592-1992 including proper rainwater receiving recess withPolyvinyl Chlorideplug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 milimeter to 40 milimeter from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on Cement concrete or masonry blocks, including necessary scaffolding and maintenance for 3 years for any leakages or dislocations of pipes. All the Polyvinyl Chloridefittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.
118Providing and fixing lightening conductor system comprising of erecting Air-Termination consisting of tubular copper rod of 25 milimeter diameter 1.2 milimeter thick with multiple points head 1.2 metre long ( Heavy Duty) welded or clamped to Galvanised iron pipe pole B grade 50 milimeter diaof requiired length with Mild steel round bnase plate 25 Centimeter diam and 10 milimeter thick at bottom embeded in cement concrete 1:3:6 dfoundation of size 45 Centimeter diameter x 45 Centimeter Height and providing earthing with copper earth plate of size 60 x 60 x 0.30 Centimeters with cadmium plated nut bolts to fix earthing strip burried in specially prepared earth pits 1.5 metre below ground level with 40 Kilogram charcoal and salt with altemate layers of charcoal and salt and Galvanised iron pipe 40 milimeter diameter 2 meter length burried in earthe upto earthling plate remining portion above ground level for watering and refilling comcpete Note- Copper strip fropm lightening conductor is not considered in this item.
119Providing and fixing copper strip 25 milimetre wide and 3 milimetre thick for lightening conductor including fixing with screws required scaffolding etc.complete Note- Lightening conductor and earthing pits is not considered in this item
120Lowering down the debris obtained from breaking and removing the cement plaster / burnt brick masonry of the first floor by any means without causing dust nuisance and damage to structure, stacking the same as and where directed including cleaning the site complete.
121Providing & fixing of Casement fixed window of approved make with Double Glazing Unit (DGU) The extruded aluminium sections of Alloy 6063 tolerances confirming to Deutsches Institut für Normung (DIN) standard from approved raw material V2 / V4 as directed by Engineer in charge.
122RWH - Recharge PitProviding and constructing recharge pit of 2.0 meter deep and 1.0 meter dia of pre-cast Reinforced cement concrete rings with 6.5\\" diameter x 25 meter deep borewell at the floor of recharge pit including installation of combination of solid/perforated Polyvinyl Chloride casing pipe wrapped around with netlon mesh including 300 milimeter thick sidefilling around outside of Reinforced cement concrete rings (annular space) with 40milimeter size boulders including filling of recharge pit up to 0.5 meter depth with 25-75 milimeter clean washed gravels from bottom up followed by 0.5 meter depth of 10-25 milimeter of clean washed stones followed by 0.5 meter of washed river fine aggregate (natural sand/ crushed sand Vertical Shaft Impactor Grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand Vertical Shaft Impactor Grade finely washed etc.) media layer including covering with Reinforced cement concrete slab, manhole frame & cover, Polyvinyl Chloride rungs, Polyvinyl Chloride end-caps, fittings etc. including arrangement for inlet & outlet pipe excavation & backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge.
123FL500 for the catchment upto 500 square meter system size 110 milimter diameter inlet, 90 milimter diameter clean water outlet, 110 milimter diameter drain outlet (filterain, tee, doorbend, valve 90 milimter)
124Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 milimeter sand cast Iron P or S trap, 10 litre low level white Polyvinyl Chloride flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to Indian standard : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :
125Providing and fixing white glazed earthenware lipped flat back/corner type Urinal with Polyvinyl Chloride 5 liters flushing cistern with fittings,inlet pipe with stop tap,brackets for fixing the cistern,32 milimeter diameter Polyvinyl Chloride flush pipe with fitting including lead soil pipe, lead trap and soil pipe connection up to the outside face of wall.
126Providing & fixing Cast iron Manhole covers with frames / rings for Reinforced cement concrete , underground water storage tanks, sizes of covers. (600 milimeter diameter) NOTE:-should be provided with locking arrangement
127Providing and fixing JAQUAR MAKE, ORNAMIX Model No. 10011 Single Lever Basin Mixer without POPUP waste system with 450 milimeter long copper pipes &Brass nuts etc complete
128Providing and fixing in position Jaquar make shower, necessary accessories shower arm with flange continental series sr. no. 483
129Supply of Sink Mixer - Jaquar note:- J shape spout with wall flange of heavy duty Jaquqr make (Wall mounted). (Sink cock with J shape spout Cat. No. FLR-5309N OR consider equivalent make)
130Providing and fixing in position `Jacquar Continental' make Chrome PlatedJet Spray with flexible Chrome Platedsupply pipe, and all other accessories, complete
131Providing and fixing in position manual Sliding Door Size - 1800 x 2800 milimeter 44 milimeter Thick Leaf heavy duty manual slliding system with top track roller hanger assembly 2 numbers floor guide -1 numbers end stoppers and anti jump mechanisum suitable for shutter weight upto 150 Kilogram complete with all required hardware and accerosicrs .
132Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases (Nitrogen Oxides (NOx) , Volatile Organic Compounds (VOC’s), Carbon Monoxide (CO), Sulfur Oxides (SOx), formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs Carbon diaxoide (4.8 Kilogram / 15l). plaster crack should be filled by Acrylic base Crack seal / Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommanded applicator and he should be able to furnish stage wise on site technical reports from the concerned company technologist.Flooring And Tiling Work
133Alluminium foldable ladder for storeProviding and Fixing Foldable Alluminum Ladder 1500 milimeter height
134Providing & fixing factory-made Single leaf 2 hour fire rated door as per IS 3614 Part 2 and BS 476 Part 20 & 22, tested to (Under writers Laboratories) UL 10 C and conforming to National Fire Protection Association. (NFPA) 80 , tested at National Test Laboratory (NTL) /Central Building Research Institute (CBRI) /Automotive Research Association of India (ARAI) of Plain Steel finish type with a.) Frame of size 143 x 58 milimeter and thickness of 1.6 milimeter thick skin pass galvanized iron sheet (Conform to Indian standard 277 ) formed to single or double rebate profile b.) Shutter of 46 milimeter thickness and constructed from 1.2 milimeter thick skin pas galvanized iron sheet (Conform to Indian standard 277) infill Rockwool / Mineral wool/ Honey comb craft paper c.) Vision glass of 5 milimeter thick clear/wired glass Circular or Rectangular d.) Finish : Primed with zinc phosphate stoving primer and finished with Polyurethane aliphatic grade or epoxy paint as required of thickness 60 micron e.) Accessories : Min 8 Anchor fastener of HILTI make, min 3 Stainless steel Ball Bearing Butt Hinges, Mortise sash lock with lever handle, Mortise dead bolt , Mortise latch , Door closer , Panic bar and external trim lock and Flush bolts complete.
135Providing Water proofing treatment to newly laid fully cured concrete slab of terraces by applying first coat of polymer modified semi-viscous paste prepared by mixing polymer of approved make and Cement in 1 : 2 proportion ( 1 litre polymer : 2 Kgilogram Cement) to a neatly cleaned and dust free concrete surface and upto 300 milimeter over parapet wall prepared by removing loose and deposited material with brush and water, laying glass fibre mesh of 10 x 10 specification of approved make over tacky surface of first coat of polymer followed by second coat in transverse direction, sprinkling coarse sand over it, followed by protective mechanical cover water proof plaster 20 milimeter thick after sufficient curing apply (Indian Patent Stone) IPS 40 milimeter to 75 milimeter. thick cement concrete of 1:2:3 proportion using coarse aggregate of 10 MSA (Maximum Size of Aggregate) and water proofing compound of approved make and polypropylene fibres @ 125 gram per bag of cement making groovr 3 to 4 milimeter wide and 10 milimeter deep in concrete, in pannels of 3 meter/4 meter or as per site condition and filling the joints with poly sulphide sealant after curing including providing holler with drip moulds at the junction and finishing the concrete surface with neat cement slurry, as directed and ponding the surface as directed etc.complete ; covering 10 years guarantee against leakproofness on court Fee stamp paper of Rs 100/-
136Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area greater than 0.9 One Square Meterr made out of 4 milimeter aluminum composite panel bonded with 0.5 milimeter skin thickness on either side with white retro reflective sheeting of Class C ( Type XI Type XI Micro prismatic grade sheeting) having pressure sensitive adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25 milimeter x 25 milimeter x 3 milimeter, duly painted on back side with two coats of grey stove enamel paint and supported on two number mild steel angle iron post 75 milimeter x 75 milimeter x 6 milimeter, 3.5 meter ~ 3.9 meter long firmly fixed to the ground by means of properly designed foundation with Mix 25 grade cement concrete 45 centimeter x 45 centimeter x 60 centimeter, 60 centimeter below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 centimeter width including fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. ClassC_ ( Type XI Micro prismatic grade sheeting) sheeting shall have 10 years written warranty from the manufacturer including the Digitally Printed areas with approved printing technology with sheeting manufacturer approved inks and laminated with UV overlay film and this warranty certificate along with sheeting manufacturer attested 3 years outdoor weathering test report from Indian govt lab must be submitted to the Engineer in charge by the contractor/supplier.
137Providing and fixing board displaying information, such as \\"Name of work, Tender cost, Name of Contractor, Work completion and liability period etc\\", having rectangular shape of 1.80m x 1.20m size made up of 4 milimeter aluminum composite pannel sheet with 0.5 milimeter skin thickness on either side bonded with white retro reflective sheeting of Class C (Type XI Micro prismatic grade sheeting) having pressure sensitive adhesive. Retro reflective sheeting with specified background, border and back side reto reflective symbols, letters, numerals, arrow as per Indian road congress : 67-2012 Table No 8.3, on Mild steelangle of size 35 x 35 x 3 milimeter frame with properly cross braced Mild steel angles of size 35 milimeter x 35 milimeter x 3milimeter duly painted including Two Mild steel angle iron posts of size 65 milimeter x 65 milimeter x 6 milimeter, 3.65 meter long painted with alternate black and white bands of 25 centimeter width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 centimeter x 60 centimeterx 75 centimeter including, excavation, refilling, transportation, and labour etc complete. Class _C_ (Type XI Micro prismatic grade sheeting)) shall have 10 years written warranty from the manufacturer including the Digitally Printed areas with approved printing technology with sheeting manufacturer approved inks and laminated with (ultraviolet) UV overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.
138Providing and fixing of factory made Unplasticized Polyvinyl Chloride casement window / Fixed Window & Casement Door (White Colour) comprising Unplasticized Polyvinyl Chloride multi-chambered frame, Sash, & Mullion with wall thickness of 2.3 milimeter (+-0.2 milimeter ), duly reinforced with Galvanised iron section 1.5 milimeter, wherever required. Unplasticized Polyvinyl Chloride window & door profile shall be made in India and shall conform to British Standard European Norm (BS EN) 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter1 Tensile Impact Strength International Organization for Standardization 8256 - more than 700Kj (kilojoules) /Square meter 2 Vicat Softening Temperature EN International Organization for Standardization – 306 Shall not be < 750 Centigrade3 Charpy Impact Strength EN (European Norm) International Organization for Standardization – 179-2 Shall not be < 20 kilojoules /Square meter4 Flexural Modulus Elasticity EN (European Norm ) International Organization for Standardization – 178 Shall not be < 2200 Newton/Square milimeter5 Mean Breaking Stress for welded corner(a) For the tensile bending test EN (European Norm ) – 514 Shall not be < 25 Newton/Square milimeter(b) For the compression bending test Shall not be < 30 Newton/Square milimeter6 Heat Reversion Test Indian Standard: 4985-2000 Shall not be > 2.0 %7 Surface Spread of flame British Standard (BS) : 476 - Part 7 Classification 18 Ignitability Evaluation British Standard (BS) : 476 - Part 5 'P' Not easily ignitable9 Tensile modulus merican Society for Testing and Materials (ASTM) D 638 Shall not be < 35 (Megapascal )MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa11 Tensile Strength EN (European Norm ) International Organization for Standardization 527 Shall not be < 30 (Megapascal )MPa. All corners of frame and sash will be fusion welded. Mullion shall be welded / screwed. Ethylene Propylene Diene Monomer/ Thermoplastic Elastomer (EPDM / TPE) Gasket shall be provided in all frame, sash & mullion, wherever necessary.Thereafter, 5 milimeter Float Annealed glass shall be provided in the sash with the help of Unplasticized Polyvinyl Chloride glazing bead and hardware, i.e., friction hinge andsingle point handle (in window) and 3D Hinges and Multipoint Lock (in door) shall be provided. Window / Door shall be fixed to the wall with 100milimeter long and 8milimeter dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. Unplasticized Polyvinyl Chloride Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use.Casement Window (Big Series) frame of size 67 x 62 milimeter & Sash / Mullion of size 67 x 78 milimeter.
1392 Track 2 / 4 Sash (Big Series) window frame of size 67 x 54 milimeter & Sash of size 64 x 47 milimeter
1403 Track 3 / 6 Sash (Big Series) window frame of size 122 x 54 milimeter & Sash of size 64 x 47 milimeter
1413 Track with Mesh-2 Glass Sash + 1 Mesh Sash (Each sash shall be half of width of window) (Big Series) Window frame of size 122 x 54 milimeter & Sash of size 64 x 47 milimeter.
142Providing and fixing of factory made Unplasticized Polyvinyl Chloride Louver window (White Colour) comprising of Unplasticized Polyvinyl Chloride multi-chambered with wall thickness of 2.3milimeter (+-0.2 milimeter ), duly reinforced with 1.5 milimeter thick G. I. Section. Unplasticized Polyvinyl Chloride window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specifie Parameter1 Tensile Impact Strength International Organization for Standardization 8256 - more than 700Kj (kilojoules) /Square meter 2 Vicat Softening Temperature EN International Organization for Standardization – 306 Shall not be < 750 Centigrade3 Charpy Impact Strength EN (European Norm) International Organization for Standardization – 179-2 Shall not be < 20 kilojoules /Square meter4 Flexural Modulus Elasticity EN (European Norm ) International Organization for Standardization – 178 Shall not be < 2200 Newton/Square milimeter5 Mean Breaking Stress for welded corner(a) For the tensile bending test EN (European Norm ) – 514 Shall not be < 25 Newton/Square milimeter(b) For the compression bending test Shall not be < 30 Newton/Square milimeter6 Heat Reversion Test Indian Standard: 4985-2000 Shall not be > 2.0 %7 Surface Spread of flame British Standard (BS) : 476 - Part 7 Classification 18 Ignitability Evaluation British Standard (BS) : 476 - Part 5 'P' Not easily ignitable9 Tensile modulus merican Society for Testing and Materials (ASTM) D 638 Shall not be < 35 (Megapascal )MPa10 Shear Modulus ASTM D 732 Shall not be < 220 (Megapascal )MPa11 Tensile Strength EN (European Norm ) International Organization for Standardization 527 Shall not be < 30 (Megapascal )MPa. All corners of frame shall be fusion welded. Both vertical sides of the frame, adjustable louver mechanism having one lever or fixed louver bracket shall be fitted with the of 4 milimeter Frosted Annealed glass. Window will be fixed to the wall with 100milimeter long and 8milimeter dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. Unplasticized Polyvinyl Chloride Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration,wrapping and rotting under general use.a.Louver Window (Big Series) frame of size 67 x 62 milimeter & Mullion (if required) of size 67 x 78 milimeter.
143Providing & fixing stainless steel 20 milimeter dia,600 milimeter long grab bar for physicaly handicapped toilet etc complete as directed.
144Providing and installing crystalline waterproofing treatment to inside surfaces of the water retaining structures VERTICAL SURFACES : grooves at junctions and joints, pressure grouting the same and curing for specified period. b) Applying two coats of approved crystalline waterproofing compound at specified intervals as recommanded by manufacturer and as directed by Engineer-in charge and allowed to cure. c) Extra for Plastering of walls and finishing smooth with 15 milimeter thick cement mortar 1:4 (1 cement : 4 fine sand) admixed with approved waterproofing compound in recommanded proportions. HORIZONTAL SURFACES : d) Extra for Laying of 30 milimeter average thick cement concrete of mix 1:2:4 (1 cement : 2 coarse sand : 4 coarse aggregate of 12.5 milimeter nominal size) admixed with approved waterproofing compound in recommanded proportions, on floors to required gradient, including rounding of corners / junctions with walls and floors etc., and finished smooth and cured. Tank shall be tested by filling with water for required depth and maintaining it for 72 hours. for checking the leakages. The rate includes giving 10 year guarantee for waterproofing on a Rs.100/- stamp paper in approved proforma.
145Providing waterproofing treatment from outside to basement lift-pits and other under ground structures during construction. The treatment shall be started after the plain cement concrete bedding for the base slab or raft slab is laid. On the plain cement concrete bedding a waterproofing layer based on cement joints with 1:3 Cement sand 40 milimeter thick for floors and 20 milimeter thick for sides with cement float and water proofing compound as per specifications shall be laid. Then the surface shall be superimposed by regular Reinforced cement concrete raft or base slab as per design. After completion of the raft / base slab and side walls the treatment of waterproofing layer shall be continued along the outer surface of the walls upto a height of 30 centimeter above the adjacent ground level. (The excavation of the side around the walls shall be filled with soft earth by the contractor ). The total thickness of the treatment shall be 65 milimeter to 75 milimeter for floors and 32 milimeter to 38 milimeter for walls.
146Providing and fixing glazing panels and doors using 12 milimeter thk toughen clear glass (confirming to American Society for Testing and Materials, (ASTM) Standards C-1048) supported byc-channel (embedded in the floor) at the bottom and side edge and wall connecting profile at the top edge,stainless steel articulated counter sunk bolts threaded bolts,chemical fasterners,etc., glass panel size as per design and drawing including applying colourless sealant of joint incl. required edge polish, making glazing water tight etc. Destructive node joint test reports to be submitted for establishing the safety factor, including operating hardware, Stainless steel patch fittings, fabricated long length satin finish Stainless steel 304 handles,patchlock, floor springs etc., complete as directed by the architect for frameless patch doors,single or twin leaf shutters with fixed panel on top. Hardware-Droma BTS 80 Floor Spring.
147Proving And Fixing Stainless steel 30 mesh Jali Including Fixing In Aluminum frame of size 25 milimeter x 25 milimeter including nece Stainless steel ary Fixture and fastening etc Compete as directed by engineer incharge
148Providing and laying Cast in situ/Ready Mix cement concrete Mix 30 of trap gneiss metal for Post Tension Reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control and Data Acquisition (SCADA) enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical Shaft Impactor Grade)
149Providing and fixing in position, Double shuttered aluminium extruded powder coated Air Tight openable door leaf of size 2100 x 2200 milimeter including providing and fixing Teak Wood frame 60 milimeter x 150 milimeter., 45 milimeter thick solid code hard wood block board shutters with 25 milimeter x 45 milimeter lipping patti, allround the shutter and finished with 1milimeter thick approved textured laminates on either sides, finishing all exposed surfaces of wood with approved shade french polish, treating all the surfaces of wood in contact with masonary with tar paint (Black Japan), chrominum plated brass fittings and fastenings, Stainless Steel handles etc. complete as per detailed drawing and as directed by the Engineer In charge.
150Providing and fixing in position, Single shuttered aluminium extruded powder coated Air Tight openable door of overall size 0.90 meter x 2.40 meter with aluminium door frame of powder coated section 101.60 x 44.75 milimeter , 3.18 milimeter thick and shutter comprising of powder coated section having bottom and lock rail of size 150 milimeter x 44.5 milimeter x 3.00 milimeter thick top rails 47.62 x 44.45 milimeter x 3.00 milimeter thick , vertical style 47.62 x 44.45 milimeter, 3.00 milimeter thick and for shutter plain glass panes 5 milimeter thick for top panels and 12 milimeter thick both side laminated phenol bonded particle board panels for bottom panels etc. , Indian Standards Institution mark , heavy duty, Hydraulic floor spring of 150 Kilogram capacity , having heavy duty concealed lock, necessary beading, glazing clips, Polyvinyl Chloride gaskets, 250 milimeter length tower bolts, 150 milimeter diam. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc.Complete
151Design, Supply and Installation of Bonded/Unbonded Post Tensioning System for Post tensioning Elements of appropriate Sizes including all Labour, machineries, tools and tackles, all consumables like Anchor blocks, wedges etc., all lead and lift, transportation etc. complete. Rate to include laying of tendons, stressing of tendons as per the drawing, design and instructions of Engineer-in-charge. Rate to include supplying drawings and designs along with the design reports and calculation of Post Tension members to structural consultant and getting approval from them and also submission of drawings of Post Tension members on completion of work.
152This Polyurethane concrete-based floor topping system for areas which shall be predominantly subjected to very high thermal shocks (70°Centigrade to 150°Centigrade) and regular movement of heavy forklifts and trolleys/stackers with hard Polyurethane (PU), hard rubber or steel wheels, such as production halls of an engineering plant, aisles/corridors in engineering, automobiles plants, tyre manufacturing plants, aircraft hangers, maintenance workshops etc.The 6 milimeter to 9 milimeter Polyurethane (PU) coating Floor topping system :1.Surface Preparation: floor must be cleaned followed by Grinding with Scarifier to make the surface rough for proper bonding. Groves to be prepared as per requirement.2. Priming scratch coat: A thin layer of Polyurethane concrete flooring system over a prepared substrate at thickness of 1 milimeter to seal the pores of concrete.2. Top Layer: On drying of the scratch coat but before 48 hours. of scratch coat application, the Polyurethane concrete flooring system topping layer shall be applied at a thickness of minimum 3 milimeter to form a total thickness of minimum 4 milimeter including the scratch coat. (For 7 milimeter system it should be 6 milimeter)
153food and fruit compost machine 400 kilogram per day ( kilogram/day)These machines are often fully automatic, constructed from stainless steel .General Technical Specifications Capacity: 400 kilogram per dayProcess Duration: 24 hoursVolume Reduction: 80% to 90% reduction of waste volumeConstruction Material: Stainless steel (SS) 304 Stainless Steel (corrosion-resistant)Power Supply: 3 Phase (380V - 440V)Power Consumption: 3 Horse Power to 5 Horse Power(approximate range)Automation: PLC-based (Programmable Logic Controller) with a touch screen interfaceAverage Dimensions (LxWxH): Approx 2065 milimeter x 1700 milimeter x 1330 milimeterWeight: ~1100 kilogram to 1200 kilogram .Odour Control: Features activated carbon filters and airtight chambers for odourless, eco-friendly operation.Automatic Operation: \\"Feed and Forget\\" systems that manage temperature and moisture levels automatically.
154Key Features and Functional Details:Inbuilt Shredder: Equipped with high-strength alloy blades (often 4140 alloy) to shred food waste, eliminating the need for a separate shredder.Safety Features: Emergency stop buttons, motor overload protection, and automatic shut-off.Input Types: Cooked food, vegetable peels, fruit waste, meat, and fish bones.End Product: Dry, nutrient-rich soil fertilizer. Components and Power Management:Main Motor: Typically a heavy-duty commutator motor for stirring and mixing.Heater: Insulated jacket heater for, even heating of the waste to, optimal temperatures (55°Centigrade - 65° Centigrade).
155Supplying on site fresh Garden soil (free from stones rubbish like dried grass roots, other such materials) for excavation area of depth of 30 centimeters. (consolidated thickness)
156Supplying on site well decomposed Farmyard Manure for excavation area of depth of 30 centimeters. (consolidated thickness)
157Providing on site required variety of Shrubs (free from weeds /diesease etc.) 30 centimeters.. apart center to center Name:- Murraya(Kamini); Bag Size 7'' x 8'',
158Excavation for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed in earth, soil of all types, soft murum, including removing the excavated material up to a distance of 50 meters for a depth of 30 Centimeters.
159Filling fresh garden soil / silt and manure in excavated area of depth 30 Centimeters
160Mixing garden soil/silt and manure thoroughly well, watering previous night. Planting reqired plant species, lawn grass as directed etc. complete for required depth 30 centimeters for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed/ ground cover. (1/10 of semiskilled labour)
161Maintenance of Newly Developed Shrubbery/ Hedges/ Edges/ Ground covers Area. For First 30 days Only
162Providing and Fixing of POP UP SPRAY 4\\" size (SPRINKLER) of rigid plastic on site. It is anufactured from special grade vergin polymers. Parts resistent to corrosion in treated recycled water containing chlorine and other chemicals. Strong stainless stell spring provides reliable stem retraction and withstands corrosion.1) working pressure:1-4 kilogram/square meter 2)Discharge flow:0.15-0.85 Cubic Meter/Hour. 3)Radius:3 to 5.5 meter 4)Inlet size: 1/2\\" female threaded inlet 5)Rugged ribbing case for maximum strength and durability. 6)part and full circle in one head
163Providing and Fixing of POP UP SPRINKLER 9.5\\" of rigid plastic on site. The Pop sprinkler powerful throw permits maximum spacing and offers superior close in watering and uniform water distribution. Low pressure loss and efficient, staight through flow design conserve energy and are ideal for dirty water application. Non strippable gear drive function. Rate is inclusive of all type of taxes, transportation, loading, unloading, laying, all reuired labour etc.complete as directed by engineer in charge1) working pressure:2-4 kilogram/square metre 2)Discharge flow: 0.35-1.86 Cubic Meter/Hour. 3)Radius: 6 to 13 meter4)Inlet size: 1/2\\" female threaded inlet 5)Rugged ribbing case for maximum strength and durability.6)part and full circle in one head
164Providing and fixing Dripper of 4 liter per hour discharge 75 centimeter center to center on the Low-Density Polyethylene. lateral, Jain makeas directed by the Engineer In charge.
165Providing and Fixing of SAND FILTER (GRAVEL FILTER) with on site. It shoud be vertical with mushroom fitted on plate seperating sand bed and clean water chamber with a sand bed depth of about 500milimeter. It shoud be installed with vacOne Cubic Meter breakers to prevent vacOne Cubic Meter inside the filter. The shell should be provided with a drain plig at bottom to drain out fine sediments and aside hand hole to facilate easy removal of sand from the shell whenever the sand needs replacement. The filter housings should be protected by an extra durable epoxy paint from outside and black bituminous paint from onside. As directed by Engineer incharge.
166Providing and fixing on site gun metal gate valve of approved make of 63 milimeter diameter,having wall thickness of 7 milimeter. Pressure rating of 10 bar. The item includes all labour, tools, equipment, transportation, loading & unloading complete with proper fixtures and fasteners, necessary for installation as per drawing and specification attached and as directed by the Engineer In charge of the work.
167Providing earth work in embankment with approved materials obtained from departmental land or other sources upto lead of 50 meter including all lifts, laying in layers of 20 centimeter to 30 centimeter thickness breaking clods, dressing to the required lines, curves,grades and section, watering and compaction with vibratory roller with vibratory system (VS) at attachment to achieve not less than 97 % of standard proctor density etc. complete
168Supplying on site fresh Garden soil (free from stones rubbish like dried grass roots, other such materials) for excavation area of depth of 30 centimeters (consolidated thickness).
169Supplying on site well decayed, well dried, well powdered, without clods and free from stones, dried grass and other rubbish material. The color of the manure generally is black. The manure will be measured by measuring box. (Farma)
170Rose plant: - Excavation pit size 0.30 x 0.30 x 0.30 meter for planting rose plants/ climbers/ creepers in earth, soil of all types, soft murum, including removing the excavated & unwanted material up to a required distance of 50 meters
171Mogra plant: - Excavation pit size 0.30 x 0.30 x 0.30 meter for planting rose plants/ climbers/ creepers in earth, soil of all types, soft murum, including removing the excavated & unwanted material up to a required distance of 50 meters
172Providing and planting Rooted plants in microbag/ polybag for edge/Border plant including excavating the ground to a required depth , removing conveying unwanted stuff to a required distance as directed by engineer incharge.
173Providing and planting rooted plants for hedge in polybag plant including excavating the ground to a required depth, removing and conveying unwanted stuff to a required distance as directed engineer incharge.
174Providing on site required variety of lawn (free from weeds /diesease etc.) Cynadon/ paspalum/ selection for 1 square metre area dibbling distance 5 centimeters apart center to center
175Providing on site well established (free from weeds /disease etc.) ready to fix lawn turf in slabs/ rolls of required variety as directed.
176saplings of flowering /shady trees, gulmohar, raintree, peltophorum etc. height minimum to 1meter.
177saplings of flowering /shady trees, gulmohar, raintree, peltophorum etc. height minimum to 2 metres
178Providing on site required variety of Shrubs (free from weeds /diesease etc.) 30 centimeters apart center to center Name:- Murraya(Kamini); Bag Size 7'' x 8'',
179Providing on site required variety of Tree (free from weeds /diesease etc.) 30 centimeters apart center to center Name:- Bahava;Bag Size 13 x13'', ht 6-8'
180Preparing Lawn (30 centimeters Depth) Excavating the ground to a required depth of 30 centimeters, removing & conveying unwanted stuff to a required distance as directed. Filling fresh garden soil/silt and manure in excavated area in 3:1 proportion to a height of 30 centimeters . Mixing garden soil and manure thoroughly, well, levelling, watering on previous night. Planting required variety of lawn grass as directed and maintaining till well established by watering, weeding, clipping, rolling, etc Complete.
181Preparing Instant Lawn: - Excavating the ground to a required depth of 20 centimeters Removing & conveying unwanted stuff to a required distance as directed. Filling fresh garden soil & manure in excavated area in 3:1 proportion to a height of 20 centimeters. Mixing garden soil & manure thoroughly, well, leveling, wth required slope, light watering on previous night, rolling, on surface, fixing readymade lawn truf, rolls or slabs of required variety of lawn grass as directed. Ramilimetering on it for proper fixing and maintaining till well established by watering, weeding, clipping rolling, etc complete.
182Preparing Edging or Border: Excavating the ground to a required depth of 20 centimeters., in the required area, removing and conveying unwanted stuff, rubbish to the required distance as directed. Filling the excavated part with fresh soil and manure in 3:1 proportion to a required height of 20 centimeters. Mixing, levelling, watering the same. Planting rooted edging/border plants at distance of 20 centimeters. Apart by watering, weeding, stirring of soil replacing casualties, pruning if necessary etc. Complete.
183Planting clipped Hedge: Excavating the ground to a required depth of 30 centimeters, removing and conveying unwanted stuff to a required distance as directed. Filling fresh garden soil and manure in excavated area in 3:1 proportion to a height of 30 centimeters. Mixing garden soil and manure thoroughly well, levelling, watering previous night. Planting hedge plants of required species in two rows. Distance between two rows & between two plants will be 25 centimeters. Maintaining till well established by watering, weeding, stirring the soil and clipping if necessary etc. Complete.
184Preparing flower bed: Excavating the ground to the required depth of 30 centimeters, Removing and conveying unwanted stuff to a required distance as directed, Filling fresh garden soil and manure in excavated area in 3:1 proportion to a required height of 30 centimeters Mixing garden soil and manure thoroughly well, levelling, watering on previous night. Planting seedlings of required annuals 25 centimeters. Apart Maintaining till well established by watering, weeding, stirring replacing of casualties etc. Complete.
185Preparing canna bed: - Excavating the ground to a required depth of 30 centimeters. Removing & conveying unwanted stuff to a required distance as directed. Filling fresh garden soil andmanure in excavated area in 2:1 proportion to a height of 30 cm. Mixing garden soil & manure thoroughly, well, leveling, watering on previous night. Planting well devoloped canna rhyzomes 40 centimeters apart. Maintaining till well well established by watering, weeding, stirring replacing of casualties etc, complete.
186Preparing shrubbery: Excavating the ground to required depth of 30 centimeters, removing and conveying unwanted stuff to a required distance as directed. Filling fresh garden soil and Manure in excavated area in 3:1 proportion to a height of 30 cms. Mixing garden soil and manure thoroughly well, levelling, watering on previous night. Planting well developed shrubs plants, 0.50 meters. Height, 0.45 Meters. Apart as directed and maintaining till well established by watering, weeding, stirring, replacing casualties etc. Complete.
187Rose plant: - Excavating pit with size 0.30 meter x 0.30 meter x 0.30meter. Removing and conveying unwanted stuff to a required distance as directed. Filling fresh garden soil and manure in excavated area in 3:1 proportion to a height of 30 centimeter . Mixing garden soil and manure thoroughly, well, leveling, watering on previous night. Planting 40 to 50 centimaters height healthy plant of required rose variety and maintaining till well well established by watering, weeding, stirring, prunning replacing of casualties etc, complete.
188Planting large flowering/shady trees: (Minimum Height to 1 meter ) - Digging pit with size 0.90 meter x 0.90 meter x Height to 1 meter.) - Digging pit with size 0.90 meter x 0.90 meter x 0.90 meter removing and conveying unwanted stuff to a required distance as directed. Filling the pit with approved excavated material upto a height of 0.30 meter and remaining height of 0.60 meter With fresh garden soil and manure in 3:1 proportion. Mixing soil and manure thoroughly well, leveling, as directed, watering previous night, planting one to two year old, minimum 1.0 meter Height, healthy tree sapling as per specifications. Maintaining till well established by watering, weeding, stirring of soil, staking, replacing of casualties etc. Complete.
189Excavation pit size 0.60 x 0.60 x 0.60 meter for planting small and medium ornamental plants/ large flowering/ shady trees (plant height 1 to 2 meters )/ palm varieties upto height 1 to 2 meters in earth, soil of all types, soft murum, including removing the excavated and unwanted material up to a required distance of 50 meters
190Planting small & medium size Ornamental / Flowering plant: -Digging pit with size 0.60 meter x 0.60 meter x 0.60 meter. Removing and conveying unwanted stuff to a required distance as directed. Filling the pit with fresh garden soil andfarmyard manure up to a height of 0.60 meter in 3:1 proportion. Mixing garden soil and manure thoroughly, well, leveling, watering on previous night. Planting one to two year old healthy tree saplings. Maintaining till well established by watering, weeding, stirring replacing of casualties etc. complete.
191Preparing ground covers: Excavating the ground to a required depth of 20 centimaters . Removing and conveying unwanted stuff, rubbish to the required distance as directed. Filling the Excavated area with fresh garden soil and Farm Yard Manure Manure in 3:1 proportion to a height of 20 centimaters, Mixing, levelling, watering the same on previous night. Planting suitable ground covers as directed in staggering pattern distance between two rows 25 centimeters , watering & maintaining till well established.
192Kitchen TrolleyProviding and Fixing stainless steel kitchen trolley of overall 26\\" height and 22\\" depth, supported on aluminium pipes ,trolley basket made out of 5 milimeter stainless steel rod fitted on telescopic channel of size 1.5 \\" x 20 \\" x 22 \\" on both sides of trolley of 12 \\" or above size, panel having 40 Kilogram load bearing capacity of trolley made out of 20 milimeter Polyurethane Conformal Coating (PUC) coated plywood and colour combination as directed by Engineer Incharge Inner side of panel covered by white mica ,100 milimeter stainless steel decorative handle. (The width and height of individual compartments shall be kept as directed by Engineer-in-charge)
193Directional signageDesign, supply, fabrication and fixing acrylic multilingual Braille (raised dots) directional signboards of size 6\\" x 9\\" designed as per accessibility standards and having 4milimeter thick acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15milimeter raised not less than 0.8milimeter above base plate and the equivalent word written in Hindi with Devnagri non glare acrylic letters of height 15milimeter raised not less than 0.8milimeter above base plate and having a non glare acrylic cut arrow pointing in the required direction. Each signboard to be fixed as per manufacturers specifications on the wall at the approved location and at a height of 1200 milimeter from floor finish level (FFL) and as per the directions by the engineer in charge.
194Floor Directories Providing and fixing acrylic multilingual Braille (raised dots) Americans with Disabilities Act (ADA) compliant modular floor directories system on all floors of size1.5' x 2' , showing the floor plan and the list of rooms on that floor, to be installed on each floor near the staircase, designed as per standards and having 4milimeter thick blue acrylic base plate with Upper Case San Serif words and symbols made of white acrylic non glare cut out letters of height 20 milimeter raised not less than 0.8 milimeter above base plate and the equivalent word/s written in Hindi with Devnagri non glare imported acrylic letters of height 15 milimeter raised not less than 0.8 milimeter above base plate. Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5 milimeter above base plate. Each directory to be fixed as per manufacturers specifications on the wall at the approved location at a height of 1200 milimeter from floor finish leve (FFL) and as per the directions by the engineer in charge.
195Fire exit and floor identification signage as per manufacturer's specifications, Americans with Disabilities Act. compliant and modular system
196Providing and fixing Stainless steel -304 strips of size 280milimeter x 35milimeter of the approved brand and make inside the building on all floors in corridors, lobbies level differences etc. as per accessibility standards and as per the installation instructions prescribed by the manufacturer, using the necessary adhesive including finishing work up to the satisfaction of the engineer in charge complete.
197Providing and fixing Modular false ceiling of 600 x 600 milimeter center to center and 13 milimeter thick square mineral fiber board to be fixed on frame work of alluminium sections for suspended false ceiling consisting of alluminium T2”x1½” (50 milimeter x 40 milimeter) weighing 0.39 Kilogram/meter at 60cms center center and fixed with ½”x½” (15 x 15milimeter) flanges weighing 0.19 Kilogram / meter suspended on 6 milimeter diameter mild steel rod weighing 0.22 Kilogram/m, fixed on wall and beams including rounding of the edges with aluminium T of 2” x 1 ½” (50 mm x 40 mm) weighing 0.39 Kilogram/meter etc (all alluminium sections shall be anodized) including all labour, material, lifts etc. complete.
198Providing and fixing in position Gypsum board false ceiling with 12.5 milimeter thick Gypsum boards, screwed / fixed to the under structure of suspended Galvanised iron Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 milimeter maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from under side to give smooth, seamless ceiling. The rate should includ enecessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cutouts, painting including labour, material, lifts etc. all complete.
199Providing and fixing white vitreous china laboratory sink with Cast iron brackets, Chrome Plated brass chain with rubber plug, 40 milimeter Chrome Plated brass waste and 40milimeter Chrome Plated brass trap with necessary Chrome Plated brass unions complete including painting of fittings and brackets, cutting and making good the wall wherever required :
200Providing & fixing FULL HEIGHT FULLY GLAZED PARTITION at required location having height approx.2.80 meter by using 10 milimeter thick toughened float glass fixed in 50 milimeter x 100 milimeter approved quality seasoned teak wood section at top & bottom rail with necessary lipping Burma Teakwood Category (BTC) moulding & fixtures etc.complete. Antitermite treatment to woodwork,door frame &melamine polish to all woodwork including all leads & lifts etc complete as per architects Drawing and instructions of Engineer In Charge.
201Providing & fixing FULL HEIGHT BOTH SIDE LAMINATED PARTITION at required location having height more than 2.8 meter & minimum 77 milimeter thick made by using 50 x 50 milimeter (finished size) approved quality seasoned teakl wood section framing at 600 milimeter center to center,covered with 12 milimeter marine ply generally confirming to Indian Standard303 / Indian Standard 710-1980 on both sides. The partitions shall be finished with 1.5 milimeter thk.approved quality laminate matt/suede/fine line finished lamination pattern with grooves on both sides with necessary lipping Burma Teakwood Category (BTC) moulding. Antitermite treatment to plywood and woodwork, door frame including all leads & lifts etc complete as per Architect's Drawing and instructions of Engineer In Charge.
202Providing, supplying, fabricating and fixing panel of aluminium composite panel cladding in approved shape made out of 4 milimeter thick aluminium composite panel (ACP) sheet material consisting of 3 milimeter thick Fire Retardant (FR) grade mineral core following National Building Code (NBC) part IV Fire and life safety (having 2 hours fire resistance in accordance to American Society for Testing and Materials (ASTM) E119-12 and British standard (BS) 476 part 6 and 7 class O) sandwitched between two aluminium sheets (each 0.5 milimeter thick of aluminum-manganese/magnesium alloys (AA) 5005/AA3105 grade) The aluminium composite panel cladding sheet shall be coil coated with kynar 500 based (Polyvinylidene Fluoride/Difluoride (PVDF)/Lumiflon based fluropolymer resin (having 70:30 ratio of Polyvinylidene Fluoride/Difluorideand acrylic) coating of approved colour and shade on top face and polymer (service) coating of bottom face as specified using stainless steel screws, nuts, bolts, washers,cleats,weather silicon sealent,backer rods etc .overall weight of the aluminium composite panel shall not be less than 7.5 Kilogram/ One Square Metre)
203PART B Plant and Machinery (2.001 to 11.021)
204Supply, Installation, Testing & Commissioning of 1.1 KV grade, Stranded aluminium conductor, Cross-Linked Polyethylene (Cross-Linked Polyethylene (XLPE)) insulated, armoured, PVC outer sheathed cables conforming to Indian Standard: 7098 ( Part-I ). The rates shall be inclusive of laying of cable in provided Trench/Pipe/Cable Tray. Termination of cables using double compression gland, crimping type lugs, etc. Each termination shall include supply of all necessary components, accessories, including double compression cable gland, cable lugs (crimping type) and consumables to make a complete termination in such a way that no live parts of the terminal and connecting lugs are exposed. While making termination, all other protection arrangement shall also be ensured. The cable tagging with proper ferrules shall be supplied & installed by the Contractor as part of cable termination work. Testing of the cables shall be as per specification & results shall be submitted to Engineer-in-Charge duly signed by contractor and authorized representative. Before Commissioning of cables Contractor need to check for physical damages & proper connection of all the terminals.
205Supplying, erecting & terminating FR Cross-Linked Polyethylene (Cross-Linked Polyethylene (XLPE)) insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½core 400 sq. milimeter. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL, CSR-2022-23
206Supplying, erecting & terminating FR Cross-Linked Polyethylene (Cross-Linked Polyethylene (XLPE)) insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. milimeter. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL, CSR 2022-23
207Supplying, erecting & terminating FR Cross-Linked Polyethylene (Cross-Linked Polyethylene (XLPE)) insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½core 240 sq. milimeter. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL, CSR 2022-23
208Supplying, erecting & terminating FR Cross-Linked Polyethylene (Cross-Linked Polyethylene (XLPE)) insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. milimeter. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL, CSR 2022-23
209Supplying, erecting & terminating FR Cross-Linked Polyethylene (Cross-Linked Polyethylene (XLPE)) insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 120 sq. milimeter. aluminium conductor complete erected with glands & lugs, on wall/trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL, CSR 2022-23
210Supplying, erecting & terminating FR Cross-Linked Polyethylene (Cross-Linked Polyethylene (XLPE)) insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. milimeter. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL, CSR 2022-23
211Supplying, erecting & terminating FR Cross-Linked Polyethylene (Cross-Linked Polyethylene (XLPE)) insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. milimeter. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL, CSR 2022-23
212Supplying, erecting & terminating FR Cross-Linked Polyethylene (Cross-Linked Polyethylene (XLPE)) insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. milimeter. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL, CSR 2022-23
213Supplying, erecting & terminating FR Cross-Linked Polyethylene (Cross-Linked Polyethylene (XLPE)) insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. milimeter. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL, CSR 2022-23
214Supplying, erecting & terminating FR Cross-Linked Polyethylene (Cross-Linked Polyethylene (XLPE)) insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. milimeter. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU, CSR 2022-23
215Supplying, erecting & terminating FR Cross-Linked Polyethylene (Cross-Linked Polyethylene (XLPE)) insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. milimeter. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU, CSR 2022-23
216Supplying, erecting & terminating FR Cross-Linked Polyethylene (Cross-Linked Polyethylene (XLPE)) insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 2.5 sq. milimeter. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU, CSR 2022-23
217Supplying, erecting & terminating FR Cross-Linked Polyethylene (Cross-Linked Polyethylene (XLPE)) insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 2.5 sq. milimeter. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU, CSR 2022-23
218Supplying, erecting & terminating FR Cross-Linked Polyethylene (Cross-Linked Polyethylene (XLPE)) insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 2.5 sq. milimeter. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification
219Supplying, erecting & terminating FR Cross-Linked Polyethylene (Cross-Linked Polyethylene (XLPE)) insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 1.5 sq. milimeter. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification
220Providing & erecting hot dipped galvanised perforated type cable tray manufactured from 16 SWG (1.6 milimeter thick) GI sheet of 400 milimeter width & 75 milimeter height complete with necessary coupler plates & hardware. CSR 2022-23
221Providing & erecting hot dipped galvanised perforated type cable tray manufactured from 16 SWG (1.6 milimeter thick) GI sheet of 300 milimeter width & 75 milimeter height complete with necessary coupler plates & hardware. CSR 2022-23
222Providing & erecting hot dipped galvanised perforated type cable tray manufactured from 16 SWG (1.6 milimeter thick) GI sheet of 150 milimeter width & 75 milimeter height complete with necessary coupler plates & hardware. CSR 2022-23
223Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 milimeter thick) GI sheet of 400 milimeter width & 20 milimeter height complete with necessary hardware. CSR 2022-23
224Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 milimeter thick) GI sheet of 300 milimeter width & 20 milimeter height complete with necessary hardware. CSR 2022-23
225Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 milimeter thick) GI sheet of 150 milimeter width & 20 milimeter height complete with necessary hardware. CSR 2022-23
226Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003Non-Pressure (NP)-2 class of 150 milimeter internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. CSR 2022-23
227Supplying & laying (including excavation) half round reinforced cement concrete pipe of IS 458:2003 Non-Pressure (NP)-2 class of 150 milimeter internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. CSR 2022-23
228Supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 milimeter outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. CSR 2022-23
229Supplying and laying (including excavation of suitable width & depth up to 90 cm) 160 milimeter outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. CSR 2022-23
230Making trench in soft soil having 0.75 m depth and minimum 0.3 m width for laying provided cables up to voltage level of 1.1kV complete As per specification No. CW-EXN-CTR, CSR 2022-23
231Making trench in Hard murum/Tar road having 0.75 m depth and minimum 0.3mtr width as per IS for laying provided cables up to voltage level 1.1Kv cable complete as per specification No. CW-EXN-CTR. CSR 2022-23
232Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP. CSR 2022-23
233Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 milimeter diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kilogram Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the resultsSpecification no. EA-MOBI
234Supply, Installation, Testing & Commissioning of earthing station using pipe in pipe earthing electrode with complete system as per specs. Including boring, civil work, chamber etc. Earthing shall be carried out as described in IS-3043-1960 code. Pipe in pipe earthing electrode system shall be as per enclosed technical specifications. The entire earthing system should be executed as per system supplier’s instructions. The Earthing Chamber with all the necessary material required for earthing shall be in Contractors scope. Testing of the Earthing system shall be as per specification & results shall be submitted to Engineer-in-Charge duly signed by contractor and authorized representative. 2 meters Length Earthing Electrode
235Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EAEP. CSR 2022-23
236Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. CSR 2022-23
237Supplying and erecting annealed bare copper wire of high purity of required sizes used for earthing on wall with necessary copper clamps fixed on wall/cable/conduit with screws complete. CSR 2022-23
238Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/conduit with screws complete. CSR 2022-23
239Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 milimeter dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete.
240Supply, Installation, Testing & Commissioning of Main Power Control Center Panel (MPCC), having MSEDCL Incomer - I : 5000 Amp. 4 pole 80 KA EDO ACB with microprocessor based release for LSIG protection, with U/V & EF protections & Commissioning facility, 96 sq.milimeter. 0-500 V Digital Voltmeter, 96 sq.milimeter. 0-5000 A Digital Ammeter with CT's., Multi function energy meter 1.0 class with RS 485 Commissioning port & CT's., Indicating lamps, Control MCB, & Neutral Link - as required. DG Set Incomer - II : 5000 Amp. 4 pole 80 KA EDO ACB with microprocessor based release for LSIG protection, with U/V & EF protections & Commissioning facility, 96 sq.milimeter. 0-500 V Digital Voltmeter, 96 sq.milimeter. 0-5000 A Digital Ammeter with CT's., Multi function energy meter 1.0 class with RS 485 Commissioning port & CT's., Indicating lamps, Control MCB, & Neutral Link - as required. MSEDCL Incomer - I and DG Set Incomer - II Electrically and Mechanically interlocking shall be provided. 8\\" Ventilation fans with filters & MCB for protection in each section of panel and in addition to that wherever necessary with start stop Push Buttons shall be provided
241Outgoing : 1600 Amp. 4 pole 50 KA EDO ACB with microprocessor based release for LSIG protection, with U/V & EF protections & Commissioning facility, Indicating lamps, Control MCB, & Neutral Link - as required - 4 Nos., 1250 Amp. 4 pole 50 KA EDO ACB with microprocessor based release for LSIG protection, with U/V & EF protections & Commissioning facility, Indicating lamps, Control MCB, & Neutral Link - as required - 2 Nos., 1000 Amp. 4 pole 50 KA EDO ACB with microprocessor based release for LSIG protection, with U/V & EF protections & Commissioning facility, Indicating lamps, Control MCB, & Neutral Link - as required - 1 Nos., APFC Incomer 3200 Amp. 4 pole 50 KA EDO ACB with microprocessor based release for LSIG protection, with U/V & EF protections & Commissioning facility, Indicating lamps, Control MCB, & Neutral Link - as required - 1 Nos. (Note: ACB outgong shall be connected using rated busbar to APFC 1,2 &3., 630 Amp (158-630A). 4 pole 36 KA MCCB microprocessor based with rotary door handle, spreader links, phase barrier etc. - 1 Nos, 400 Amp (100-400A). 4 pole 36 KA MCCB microprocessor based with rotary door handle, spreader links, phase barrier etc. - 4 Nos, 250 Amp (63-250A). 4 pole 36 KA MCCB microprocessor based with rotary door handle, spreader links, phase barrier etc. - 3 Nos, 160 Amp (40-160A). 4 pole 36 KA MCCB microprocessor based with rotary door handle, spreader links, phase barrier etc. - 4 Nos. All outgoing feeders shall be provided with ON indication lamp.
242Panel fabricated using 14 gauge (2milimeter) CRCA sheet duly Powder coated. In each Each Section Space heater with thermostat & MCB for protection, Ventilation fans with filters & MCB for protection. Selection of ACB, MCCB shall be as per approved makes. Please refer SLD & ensure that all releases are as per specifications. Copper busbar of 6000 Amp. @ 1.2 Amp / milimeter Current Density & 50 degree C ambient temperature. Panel shall be front access only with cable entry at bottom / top. Panel will have uniform depth throughout the length of the panel. Proper shrouding shall be provided on all live terminals. Maximum height of panel shall be 2375 milimeter including base frame of 75 milimeter.
243APFC Panel 1 & 2: - 500 KVAR having Incomer 1250 Amp. 4 pole 50 KA EDO ACB with microprocessor based release for LSIG protection, with U/V & EF protections & comilimeterunication facility, 96 sq.milimeter. 0-500 V Digital Voltmeter, 96 sq.milimeter. 0-5000 A Digital Ammeter with CT's, Indicating lamps, Control MCB, & Neutral Link etc. - 1 Nos. 12 stage Relay with all required controls. Panel shall function in Auto & Manual both modes.
244Outgoing: 50 KVAR bank having incomer 160 Amp (40-160A). 3 pole 36 KA MCCB microprocessor based with rotary door handle, spreader links, phase barrier etc, 100 Amp Capacitor duty contactor with Indicating lamps, Control MCB, & Neutral Link etc. - 9 Nos.(1 No Fixed & 8 Nos controled by relay), 25 KVAR bank having incomer 63 Amp 3 pole 10 KA MCB, 63 Amp Capacitor duty contactor with Indicating lamps, Control MCB, & Neutral Link etc. - 1 Nos, 10 KVAR bank having incomer 32 Amp 3 pole 10 KA MCB, 25 Amp Capacitor duty contactor with Indicating lamps, Control MCB, & Neutral Link etc. - 2 Nos, 5 KVAR bank having incomer 16 Amp 3 pole 10 KA MCB, 16 Amp Capacitor duty contactor with Indicating lamps, Control MCB, & Neutral Link etc. - 2 Nos,
245Panel fabricated using 14 gauge (2milimeter) CRCA sheet duly Powder coated. In each Each Section Space heater with thermostat & MCB for protection, Ventilation fans with filters & MCB for protection. Selection of ACB, MCCB shall be as per approved makes. Please refer SLD & ensure that all releases are as per specifications. Aluminium busbar of 1250 Amp. @ 0.8 Amp / milimeter Current Density & 50 degree C ambient temperature. Panel shall be front access only with cable entry at bottom / top. Panel will have uniform depth throughout the length of the panel. Proper shrouding shall be provided on all live terminals. Maximum height of panel shall be 2375 milimeter including base frame of 75 milimeter.
246APFC Panel 1 & 2: - 380 KVAR having Incomer 1000 Amp. 4 pole 50 KA EDO ACB with microprocessor based release for LSIG protection, with U/V & EF protections & Commissioning facility, 96 sq.milimeter. 0-500 V Digital Voltmeter, 96 sq.milimeter. 0-5000 A Digital Ammeter with CT's, Indicating lamps, Control MCB, & Neutral Link etc. - 1 Nos. 12 stage Relay with all required controls. Panel shall function in Auto & Manual both modes.
247Outgoing: 50 KVAR bank having incomer 160 Amp (40-160A). 3 pole 36 KA MCCB microprocessor based with rotary door handle, spreader links, phase barrier etc, 100 Amp Capacitor duty contactor with Indicating lamps, Control MCB, & Neutral Link etc. - 6 Nos., 25 KVAR bank having incomer 63 Amp 3 pole 10 KA MCB, 63 Amp Capacitor duty contactor with Indicating lamps, Control MCB, & Neutral Link etc. - 2 Nos, 10 KVAR bank having incomer 32 Amp 3 pole 10 KA MCB, 25 Amp Capacitor duty contactor with Indicating lamps, Control MCB, & Neutral Link etc. - 2 Nos, 5 KVAR bank having incomer 16 Amp 3 pole 10 KA MCB, 16 Amp Capacitor duty contactor with Indicating lamps, Control MCB, & Neutral Link etc. - 2 Nos,
248Panel fabricated using 14 gauge (2milimeter) CRCA sheet duly Powder coated. In each Each Section Space heater with thermostat & MCB for protection, Ventilation fans with filters & MCB for protection. Selection of ACB, MCCB shall be as per approved makes. Please refer SLD & ensure that all releases are as per specifications. Aluminium busbar of 1000 Amp. @ 0.8 Amp / milimeter Current Density & 50 degree C ambient temperature. Panel shall be front access only with cable entry at bottom / top. Panel will have uniform depth throughout the length of the panel. Proper shrouding shall be provided on all live terminals. Maximum height of panel shall be 2375 milimeter including base frame of 75 milimeter.
249IFC PDB - I: Supply, Installation, Testing & Commissioning of IFC Power Distribution Board (IFC PDB-I), having Incomer: 1600 Amp. 4 pole 50 KA EDO ACB with microprocessor based release for LSIG protection, with U/V & EF protections &Commissioning facility, 96 sq.milimeter. 0-500 V Digital Voltmeter, 96 sq.milimeter. 0-5000 A Digital Ammeter with CT's., Multi function energy meter 1.0 class with RS 485 Commissioning port & CT's., Indicating lamps, Control MCB, & Neutral Link - 1 No. Solar Incomer: 1600 Amp. 4 pole 50 KA EDO ACB with microprocessor based release for LSIG protection, with U/V & EF protections & Commissioning facility, 96 sq.milimeter. 0-500 V Digital Voltmeter, 96 sq.milimeter. 0-5000 A Digital Amilimetereter with CT's., Multi function energy meter 1.0 class with RS 485 Commissioning port & CT's., Indicating lamps, Control MCB, & Neutral Link - 1 No
250Outgoing: 400 Amp (100-400A). 4 pole 36 KA MCCB microprocessor based with rotary door handle, spreader links, phase barrier etc. - 4 Nos, 250 Amp (63-250A). 4 pole 36 KA MCCB microprocessor based with rotary door handle, spreader links, phase barrier etc. - 2 Nos, 160 Amp (40-160A). 4 pole 36 KA MCCB microprocessor based with rotary door handle, spreader links, phase barrier etc. - 5 Nos. 100 Amp (25-100A). 4 pole 36 KA MCCB microprocessor based with rotary door handle, spreader links, phase barrier etc. - 1 Nos. All outgoing feeders shall be provided with ON indication lamp. MCB outgoing: 63 Amp FP MCB - 2 Nos, 32 Amp FP MCB - 3 Nos. Feeders having MCB's as outgoing will have double door & front doors will have a Acrylic window cutout
251Panel fabricated using 14/16 gauge (2milimeter/1.6milimeter) CRCA sheet duly Powder coated. In each Each Section Space heater with thermostat & MCB for protection, Ventilation fans with filters & MCB for protection. Selection of ACB, MCCB shall be as per approved makes. Please refer SLD & ensure that all releases are as per specifications. Aluminium busbar of 1650 Amp. @ 0.8 Amp / milimeter Current Density & 50 degree C ambient temperature. Panel shall be front access only with cable entry at bottom / top. Panel will have uniform depth throughout the length of the panel. Proper shrouding shall be provided on all live terminals. Maximum height of panel shall be 2375 milimeter including base frame of 75 milimeter.
252IFC PDB - II: Supply, Installation, Testing & Commissioning of IFC Power Distribution Board (IFC PDB-II), having Incomer: 400 Amp (100-400A). 4 pole 36 KA MCCB microprocessor based with rotary door handle, spreader links, phase barrier etc, 96 sq.milimeter. 0-500 V Digital Voltmeter, 96 sq.milimeter. 0-400 A Digital Ammeter with CT's., Multi function energy meter 1.0 class with RS 485 Commissioning port & CT's., Indicating lamps, Control MCB, & Neutral Link - 1 No
253Outgoing: 160 Amp (40-160A). 4 pole 36 KA MCCB microprocessor based with rotary door handle, spreader links, phase barrier etc. - 2 Nos. 100 Amp (25-100A). 4 pole 36 KA MCCB microprocessor based with rotary door handle, spreader links, phase barrier etc. - 2 No, All outgoing feeders shall be provided with ON indication lamp. MCB outgoing: 63 Amp FP MCB - 9 Nos, 32 Amp FP MCB - 3 Nos. Feeders having MCB's as outgoing will have double door & front doors will have a Acrylic window cutout
254Panel fabricated using 14/16 gauge (2milimeter/1.6milimeter) CRCA sheet duly Powder coated. In each Each Section Space heater with thermostat & MCB for protection, Ventilation fans with filters & MCB for protection. Selection of ACB, MCCB shall be as per approved makes. Please refer SLD & ensure that all releases are as per specifications. Aluminium busbar of 400 Amp. @ 0.8 Amp / milimeter Current Density & 50 degree C ambient temperature. Panel shall be front access only with cable entry at bottom / top. Panel will have uniform depth throughout the length of the panel. Proper shrouding shall be provided on all live terminals. Maximum height of panel shall be 2375 milimeter including base frame of 75 milimeter.
255VHT PDB - I: Supply, Installation, Testing & Commissioning of VHT Power Distribution Board (VHT PDB-I), having Incomer: 1600 Amp. 4 pole 50 KA EDO ACB with microprocessor based release for LSIG protection, with U/V & EF protections & Commissioning facility, 96 sq.milimeter. 0-500 V Digital Voltmeter, 96 sq.milimeter. 0-1600 A Digital Ammeter with CT's., Multi function energy meter 1.0 class with RS 485 Commissioning port & CT's., Indicating lamps, Control MCB, & Neutral Link - 1 No
256Outgoing: 630 Amp (158-630A). 4 pole 36 KA MCCB microprocessor based with rotary door handle, spreader links, phase barrier etc. - 1 Nos, 250 Amp (63-250A). 4 pole 36 KA MCCB microprocessor based with rotary door handle, spreader links, phase barrier etc. - 4 Nos, 160 Amp (40-160A). 4 pole 36 KA MCCB microprocessor based with rotary door handle, spreader links, phase barrier etc. - 1 Nos. All outgoing feeders shall be provided with ON indication lamp. MCB outgoing: 63 Amp FP MCB - 3 Nos, 32 Amp FP MCB - 4 Nos. Feeders having MCB's as outgoing will have double door & front doors will have a Acrylic window cutout
257Panel fabricated using 14/16 gauge (2milimeter/1.6milimeter) CRCA sheet duly Powder coated. In each Each Section Space heater with thermostat & MCB for protection, Ventilation fans with filters & MCB for protection. Selection of ACB, MCCB shall be as per approved makes. Please refer SLD & ensure that all releases are as per specifications. Aluminium busbar of 1600 Amp. @ 0.8 Amp / milimeter Current Density & 50 degree C ambient temperature. Panel shall be front access only with cable entry at bottom / top. Panel will have uniform depth throughout the length of the panel. Proper shrouding shall be provided on all live terminals. Maximum height of panel shall be 2375 milimeter including base frame of 75 milimeter.
258VHT PDB - II: Supply, Installation, Testing & Commissioning of VHT Power Distribution Board (VHT PDB-II), having Incomer: 1000 Amp. 4 pole 50 KA EDO ACB with microprocessor based release for LSIG protection, with U/V & EF protections & Commissioning facility, 96 sq.milimeter. 0-500 V Digital Voltmeter, 96 sq.milimeter. 0-1000 A Digital Ammeter with CT's., Multi function energy meter 1.0 class with RS 485 Commissioning port & CT's., Indicating lamps, Control MCB, & Neutral Link - 1 No
259Outgoing: 400 Amp (100-400A). 4 pole 36 KA MCCB microprocessor based with rotary door handle, spreader links, phase barrier etc. - 3 Nos, 100 Amp (25-100A). 4 pole 36 KA MCCB microprocessor based with rotary door handle, spreader links, phase barrier etc. - 1 Nos. All outgoing feeders shall be provided with ON indication lamp. MCB outgoing: 63 Amp FP MCB - 3 Nos, 32 Amp FP MCB - 3 Nos. Feeders having MCB's as outgoing will have double door & front doors will have a Acrylic window cutout
260Panel fabricated using 14/16 gauge (2milimeter/1.6milimeter) CRCA sheet duly Powder coated. In each Each Section Space heater with thermostat & MCB for protection, Ventilation fans with filters & MCB for protection. Selection of ACB, MCCB shall be as per approved makes. Please refer SLD & ensure that all releases are as per specifications. Aluminium busbar of 1000 Amp. @ 0.8 Amp / milimeter Current Density & 50 degree C ambient temperature. Panel shall be front access only with cable entry at bottom / top. Panel will have uniform depth throughout the length of the panel. Proper shrouding shall be provided on all live terminals. Maximum height of panel shall be 2375 milimeter including base frame of 75 milimeter.
261VHT PDB - III: Supply, Installation, Testing & Commissioning of VHT Power Distribution Board (VHT PDB-III), having Incomer: 1600 Amp. 4 pole 50 KA EDO ACB with microprocessor based release for LSIG protection, with U/V & EF protections & communication facility, 96 Square milimeter. 0-500 V Digital Voltmeter, 96 Square milimeter. 0-1600 A Digital Ammeter with CT's., Multi function energy meter 1.0 class with RS 485 communication port & CT's., Indicating lamps, Control MCB, & Neutral Link - 1 No
262Outgoing: 100 Amp (25-100A). 4 pole 36 KA MCCB microprocessor based with rotary door handle, spreader links, phase barrier etc. - 17 Nos. All outgoing feeders shall be provided with ON indication lamp. MCB outgoing: 63 Amp FP MCB - 7 Nos, 32 Amp FP MCB - 5 Nos. Feeders having MCB's as outgoing will have double door & front doors will have a Acrylic window cutout
263Panel fabricated using 14/16 gauge (2mm/1.6mm) CRCA sheet duly Powder coated. In each Each Section Space heater with thermostat & MCB for protection, Ventilation fans with filters & MCB for protection. Selection of ACB, MCCB shall be as per approved makes. Please refer SLD & ensure that all releases are as per specifications. Aluminium busbar of 1600 Amp. @ 0.8 Amp / mm Current Density & 50 degree C ambient temperature. Panel shall be front access only with cable entry at bottom / top. Panel will have uniform depth throughout the length of the panel. Proper shrouding shall be provided on all live terminals. Maximum height of panel shall be 2375 mm including base frame of 75 mm.
264VHT PDB - IV: Supply, Installation, Testing & Commissioning of VHT Power Distribution Board (VHT PDB-IV), having Incomer: 160 Amp (40-160A). 4 pole 36 KA MCCB microprocessor based with rotary door handle, spreader links, phase barrier etc, 96 Square milimeter 0-500 V Digital Voltmeter, 96 Square milimeter 0-400 A Digital Ammeter with CT's., Multi function energy meter 1.0 class with RS 485 communication port & CT's., Indicating lamps, Control MCB, & Neutral Link - 1 No
265Outgoing: 63 Amp FP MCB - 7 Nos, 32 Amp FP MCB - 11 Nos. Feeders having MCB's as outgoing will have double door & front doors will have a Acrylic window cutout
266Panel fabricated using 14/16 gauge (2mm/1.6mm) CRCA sheet duly Powder coated. In each Each Section Space heater with thermostat & MCB for protection, Ventilation fans with filters & MCB for protection. Selection of ACB, MCCB shall be as per approved makes. Please refer SLD & ensure that all releases are as per specifications. Aluminium busbar of 200 Amp. @ 0.8 Amp / mm Current Density & 50 degree C ambient temperature. Panel shall be front access only with cable entry at bottom / top. Panel will have uniform depth throughout the length of the panel. Proper shrouding shall be provided on all live terminals. Maximum height of panel shall be 2375 mm including base frame of 75 mm.
267First Floor PDB - I: Supply, Installation, Testing & Commissioning of First Floor Power Distribution Board (First Floor PDB-I), having Incomer: 1250 Amp. 4 pole 50 KA EDO ACB with microprocessor based release for LSIG protection, with U/V & EF protections & communication facility, 96 Square milimeter 0-500 V Digital Voltmeter, 96 Square milimeter 0-1600 A Digital Ammeter with CT's., Multi function energy meter 1.0 class with RS 485 communication port & CT's., Indicating lamps, Control MCB, & Neutral Link - 1 No
268Outgoing: 630 Amp (158-630A). 4 pole 36 KA MCCB microprocessor based with rotary door handle, spreader links, phase barrier etc. - 2 Nos, 400 Amp (100-400A). 4 pole 36 KA MCCB microprocessor based with rotary door handle, spreader links, phase barrier etc. - 1 Nos, MCB outgoing: 63 Amp FP MCB - 4 Nos, 32 Amp FP MCB - 3 Nos. Feeders having MCB's as outgoing will have double door & front doors will have a Acrylic window cutout
269Panel fabricated using 14/16 gauge (2mm/1.6mm) CRCA sheet duly Powder coated. In each Each Section Space heater with thermostat & MCB for protection, Ventilation fans with filters & MCB for protection. Selection of ACB, MCCB shall be as per approved makes. Please refer SLD & ensure that all releases are as per specifications. Aluminium busbar of 1250 Amp. @ 0.8 Amp / mm Current Density & 50 degree C ambient temperature. Panel shall be front access only with cable entry at bottom / top. Panel will have uniform depth throughout the length of the panel. Proper shrouding shall be provided on all live terminals. Maximum height of panel shall be 2375 mm including base frame of 75 mm.
270First Floor PDB - II: Supply, Installation, Testing & Commissioning of First Floor Power Distribution Board (First Floor PDB-I), having Incomer: 1250 Amp. 4 pole 50 KA EDO ACB with microprocessor based release for LSIG protection, with U/V & EF protections & communication facility, 96 Square milimeter 0-500 V Digital Voltmeter, 96 Square milimeter 0-1600 A Digital Ammeter with CT's., Multi function energy meter 1.0 class with RS 485 communication port & CT's., Indicating lamps, Control MCB, & Neutral Link - 1 No
271Outgoing: 400 Amp (100-400A). 4 pole 36 KA MCCB microprocessor based with rotary door handle, spreader links, phase barrier etc. - 4 Nos, MCB outgoing: 63 Amp FP MCB - 4 Nos, 32 Amp FP MCB - 3 Nos. Feeders having MCB's as outgoing will have double door & front doors will have a Acrylic window cutout
272Panel fabricated using 14/16 gauge (2mm/1.6mm) CRCA sheet duly Powder coated. In each Each Section Space heater with thermostat & MCB for protection, Ventilation fans with filters & MCB for protection. Selection of ACB, MCCB shall be as per approved makes. Please refer SLD & ensure that all releases are as per specifications. Aluminium busbar of 1250 Amp. @ 0.8 Amp / mm Current Density & 50 degree C ambient temperature. Panel shall be front access only with cable entry at bottom / top. Panel will have uniform depth throughout the length of the panel. Proper shrouding shall be provided on all live terminals. Maximum height of panel shall be 2375 mm including base frame of 75 mm.
273Supply, installation, testing & commissioning of Step-Down Transformer of 200 kVA capacity, 3-Phase, 50 Hz, suitable for 150 kW connected load, with 415 Volts ±10% primary and 200 Volts ±5% secondary voltage, dry type, air natural cooling, complete with electrolytic copper windings, CRGO silicon steel core, Class F insulation, off-circuit tap changer ±5% in steps of 2.5% on HV side, Dyn11 vector group, electrostatic shield between HV & LV, IP23 enclosure, earthing terminals, LV neutral brought out, all routine tests as per IS 2026 / IEC 60076, including foundation mounting, earthing connection, necessary hardware, accessories, documentation, and complete testing & commissioning, as per technical specifications and satisfaction of Engineer-in-Charge.
274Point wiring for light/bell/exhaust fan in 20 mm FRLS grade Heavy Mechanical Stress Polyvinyl Chloride (HMS PVC)conduit with 1.5 Square milimeter (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WGPW/SW. CSR 2022-23
275Point wiring for ceiling fan in 20 mm FRLS grade Heavy Mechanical Stress Polyvinyl Chloride (HMS PVC)conduit with 1.5 Square milimeter (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW. CSR 2022-23
276Point wiring for independent plug in 20 mm FRLS grade Heavy Mechanical Stress Polyvinyl Chloride (HMS PVC)conduit with 1.5 Square milimeter (2+1E ) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW. CSR 2022-23
277Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 Square milimeter (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/HW. CSR 2022-23
278Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 Square milimeter (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW. CSR 2022-23
279Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 Square milimeter (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW. CSR 2022-23
280Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 Square milimeter (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW CSR 2022-23
281Point wiring for independent plug in PVC trunking (casing-capping) with 1.5 Square milimeter (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW. CSR 2022-23
282Secondary point wiring for additional light/ bell point, concealed type in min 20 mm FRLS grade PVC conduit with 1.5 Square milimeter (2+1E) FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW. CSR 2022-23
283Secondary point wiring for additional light/ bell point in PVC trunking (casing-capping) with 1.5 Square milimeter (2+1E) FRLSH grade copper wire with required accessories as per specification No: WG-PW/SW CSR 2022-23
284Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW/CW. CSR 2022-23
285Supplying and erecting Heavy Mechanical Stress Polyvinyl Chloride (HMS PVC)conduit FRLS grade 25 mm dia with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. CSR 2022-23
286Supplying and laying Heavy Mechanical Stress Polyvinyl Chloride (HMS PVC)conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. CSR 2022-23
287Supplying and erecting Heavy Mechanical Stress Polyvinyl Chloride (HMS PVC)conduit FRLS grade 32 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. CSR 2022-23
288Supplying and laying Heavy Mechanical Stress Polyvinyl Chloride (HMS PVC)conduit FRLS grade 32mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. CSR 2022-23
289Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit CSR 2022-23
290Supplying and erecting Heavy Mechanical Stress Polyvinyl Chloride (HMS PVC)conduit FRLS grade 25 mm dia with PVC accessories on wall /ceiling as per specification No: WG-MA/CON. CSR 2022-23
291Supplying and erecting Heavy Mechanical Stress Polyvinyl Chloride (HMS PVC)conduit FRLS grade 32 mm dia with PVC accessories on wall / ceiling as per specification No: WG-MA/CON. CSR 2022-23
292Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON. CSR 2022-23
293Supplying and erecting PVC trunking (PVC casing-n-capping) of size 40 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.. CSR 2022-23
294Supplying and erecting PVC slotted box trunking of size 100x100 mm with accessories on wall/ceiling as per specification No: WG-MA/SLBOX. CSR 2022-23
295Supplying and erecting mains with 3x2.5 Square milimeter FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW CSR 2022-23
296Supplying and erecting mains with 3x4 Square milimeter FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW CSR 2022-23
297Supplying and erecting mains with 3x6 Square milimeter FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW CSR 2022-23
298Supplying and erecting PVC insulated PVC round sheathed 1.5 Square milimeter (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 KV. CSR 2022-23
299Supplying and erecting PVC insulated PVC round sheathed 2.5 Square milimeter (50 no. x0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltagegrade up to 1.1 kV
300Supplying and erecting PVC insulated PVC round sheathed 4 Square milimeter (56 no. x 0.30 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 KV. CSR 2022-23
301Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module duly erected. CSR 2022-23
302Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. CSR 2022-23
303Supplying and erecting modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete. CSR 2022-23
304Supplying and erecting 16 / 20 / 25 A starter (modular range) 2 module for AC unit on provided box complete & duly concealed with necessary material and connected. CSR 2022-23
305Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB. CSR 2022-23
306Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB< CSR 2022-23
307Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1. CSR 2022-23
308Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1. CSR 2022-23
309Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB. CSR 2022-23
310Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB. CSR 2022-23
311Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB. CSR 2022-23
312Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB. CSR 2022-23
313Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB. CSR 2022-23
314Supplying, erecting & marking DPMCB 6 A to 32 A, B-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB. CSR 2022-23
315Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB. CSR 2022-23
316Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB. CSR 2022-23
317Supplying and erecting blanking plate of suitable size on MCBDB.
318Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 30 A, 3 pin plug & earth socket and 30A, 3 pin plug top with 30A triple pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron / GI frame. CSR 2022-23
319Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 20A, 2 pin plug & earth socket and 20A, 3 pin plug top with 20A/30A single pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron/ GI frame. CSR 2022-23
320Supplying, erecting, testing and commissioning of 20kVA capacity online pure sine wave, with backup time of ....... hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input and 3 phase output complete with all protections as per specification no. AP-UPS. CSR 2022-23
321Supplying & erecting three phase, 415V, street light control panel up to the max load of 12kW, TPN MCB 63A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation. CSR 2022-23
322Supply, Installation, Testing & Commissioning of 39/40 Watt LED Capsule type IP 65 protection, suitable for surface mounting. System Efficacy >90, Colour Temp 6500K, CRI Value minimum 80, Operating Temperature is 0 Deg. Driver having voltage range of 120 - 300 Volts, THD less than 10%, P.F. greater than 0.95, surge protection >=2.5 KV, inbuilt over voltage & under voltage protection. Complete with mounting bracket suitable for Surface mounting, wiring etc.
323Supply, Installation, Testing & Commissioning of 20 Watt LED Capsule type IP 65 protection, suitable for surface mounting. System Efficacy >90, Colour Temp 6500K, CRI Value minimum 80, Operating Temperature is 0 Deg. Driver having voltage range of 120 - 300 Volts, THD less than 10%, P.F. greater than 0.95, surge protection >=2.5 KV, inbuilt over voltage & under voltage protection. Complete with mounting bracket suitable for Surface mounting, wiring etc.
324Supplying and erecting IP65 and IK08 rated UV shielded polycarbonate waterproof and dustproof industrial grade LED fitting (4 feet) max. 36W with high transitivity diffuser with system lumens output of min. 4300 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50 , IP20 rated, including driver with auto cutoff & auto restart feature at 325V with end caps on PVC Block/wooden board with 3 years warranty. CSR 2022-23
325Supplying and erecting CRCA powder coated corridor / passage light LED fitting (4 feet) Max. 33W with high transitivity diffuser with system lumens output of Min. 4000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. CSR 2022-23
326Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty. CSR 2022-23
32780 watt LED Highbay Light, , luminaire with ADC housing & clear cover, suitable for surface mounting. System Efficacy >90, Colour Temp 5700/6000/6500K, CRI Value minimum 80, Driver having voltage range of 110 - 290 Volts, THD less than 10%, P.F. greater than 0.95, surge protection >/= 4 KV, inbuilt over voltage & under voltage protection. Mounting height of the fitting will be around 5.0 meters. Complete with mounting bracket suitable for Surface mounting, wiring etc.
328Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 Whaving CRCA powder coated housing, polystyrene diffuser having systemlumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80,CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f.>0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of50,000 Hrs. at L70B50 including driver, having mounting arrangement withboard for surface type or spring loaded mounting clips complete with 3 yearswarranty.
329Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 7700 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuiltsurge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. CSR 2022-23
330Supplying and erecting integrated LED street light fitting 120W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 13000 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuiltsurge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. CSR 2022-23
331Supplying and erecting integrated LED Post Top 45W IP65 & IK10 class having die cast aluminium housing with UV protected polycarbonate diffuser, having system lumens output of Min.4500 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-240V, inbuilt surge protection of 2 kV, Life class of 30,000 Hrs. at L50B50, including driver complete with 2 Year warranty as per specification No FGODF/FLS2. CSR 2022-23
332Supplying and erecting street light Wall bracket made from 40 mm. dia ‘ Galvanised iron pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB. CSR 2022-23
333Providing & erecting 9 m high (clear height) galvanised octagonal pole with galvanised 1000mm single arm sword type bracket with FRP dome and ball with cable in & out junction box & terminals, foundation bolts having bottom of 155 mm A/F, top 70 mm A/F, on providedfoundation as per specification no. OH-PL/OPL
334Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF. CSR 2022-23
335Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with bird screen condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation. CSR 2022-23
336Supplying and erecting exhaust fan heavy duty 230 V A.C. 50 cycles 375/380 mm. 1400 RPM with bird screen complete erected in position as per specification no. FGFN/EXF. CSR 2022-23
337Supplying and erecting exhaust fan heavy duty 230 V A.C. 50 cycles 450 mm. 1400 RPM with bird screen complete erected in position as per specification no. FG-FN/EXF. CSR 2022-23
338Supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. CSR 2022-23
339Supplying and erecting ‘B’ class G.I .pipe / Mild steel pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. CSR 2022-23
340Supplying and erecting 12.5 m (clear height) motorized high-mast (Top -150mm, Bottom- 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per BSEN - 10025 S355/E350 & 3mm thickness, with base plate 25 mm thick x OD 520 mm grade as per IS-2062, pole made in single section & submerge arc welded, with lowering &raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, SG-DG U clamps, double drum with assembly 250 kilogram, 5x2.5 Square milimeter flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high-mast with serial number, factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with necessary accessories complete as per specification no. OHPL/HM (excluding luminaries). CSR 2022-23
341Supplying and erecting integrated LED street light fitting 160-170W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 19000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FGODF/FLS2. CSR 2022-23
342Supply, Installation, Testing & Commissioning of audio, visual alarm system for cold storage rooms. Job involves solid state Annunciator with hooter & enclosure, installed in occupied area, stay-put type push button station in each cold rooms / pre cooling rooms, cabling from cold rooms / pre cooling rooms to Annunciator. Job involves following items. 8 points Annunciator - 1 NoStay-put type push buttons. - 4 / 8 Nos.2Cx0.75 sq. mm.Copper Flexible multi stranded cable. - 150 Mtrs10Cx0.75 sq. mm.Copper Flexible multi stranded cable. - 150 MtrsJunction box - 10 pair connectionMedium duty PVC conduit of 25 mm size with standard accessories. - 100 Mtrs
343Supplying, installing, testing and commissioning SF 6 Insulated 22kV, 630A, 16kA/3sec, 1 way outdoor, extensible motorised SCADA compatible RMU, internal arc tested as per electric supply company specification consisting of 1 no. feeder with 1 VCB compliant to IEC 62271 -100, 200 and 102, as perspecification no. SW-HTS/RMU SCADA CSR 2022-23
344Supplying, installing, testing and commissioning SF 6 Insulated 22kV, 630A, 16kA/3sec, 2 way outdoor, extensible motorised SCADA compatible RMU, internal arc tested as per electric supply company specification consisting of 1 no. feeder with 1 LBS and 1 no. feeder with 1 VCB compliant to IEC 62271 -100, 200 and 102, as per specification no. SW-HTS/RMU SCADA CSR 2022-23
345Supplying, installing, testing and commissioning SF 6 Insulated 22kV, 630A, 16kA/3sec, 3 way outdoor, extensible motorised SCADA compatible RMU, internal arc tested as per electric supply company specification consisting of 2 nos. feeder with 2 LBS and 1 no. feeder with 1 VCB. compliant to IEC 62271 - 100, 200 and 102, as per specification no. SW-HTS/RMU SCADA CSR 2022-23
346Supplying, installing, testing and commissioning Station Type Lightning Arrester. Gapless Nominal Discharge Current 10 KA, Creepage Distance 25 MM/KV , IS 3070, Galvanized support shall be provided. CSR 2022-23
347Supplying, erecting, testing and commissioning 22KV HT metering cubical (compact type) approved by MSEDCL / licensee fabricated with 2 mm (14 SWG) Mild steel sheets with supporting angle, painted with powder coating / epoxy paint of required shade, copper bus bar size 25 x 6 mm, heavy duty mechanical lock, with counter meter for measuring no. of times the opening of meter door, top side cover (CT, PT cover) interlock with meter door, epoxy casted 3 nos. CT having required ratio between 25/5A to 200/5A, VA 10 or 15, Class 0.2S, epoxy casted 3 nos. PT having ratio 22000/V3/110/V3 VA 50, Class 0.2 suitable for provided trivector meter, and provision for incoming and outgoing cables complete duly tested by licensee with necessary test certificates and erected on provided plinth/ cc foundation. CSR 2022-23
348Supplying, erecting, testing and commissioning Energy meter suitable for above metering cubical, duly tested from power supply authority
349Supplying, erecting, testing and commissioning 3.15 MVA, 22/0.433 KV Transformer, Oil immersed, Air natural coold (ONAN) Outdoor type transformer, with Cable box on HV and LV side (LV side suitable box for connecting 14 Nos 3.5C x 400 Sqmm AYFY cable) or LV side suitable for 5000 Amps BUS BAR Duct. having On Load Tap Changer and RTCC. Valtage variation +5 to -15% with variation of 1.25%. General requirement as per power supply authority. CSR 2022-23
350Supplying , erecting & terminating Cross-Linked Polyethylene (Cross-Linked Polyethylene (XLPE)) insulated, galvanised steel formed wire armoured (strip) cable 22 kV(E), 3 x 300 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT CSR 2022-23
351Providing and erecting Heat shrinkable indoor termination kit for 33 kV ( E )/33 kV (UE) Cross-Linked Polyethylene (Cross-Linked Polyethylene (XLPE)) HT cable 3x300 sq. mm. to 400 sq. mm. with necessary material as per specification no. CB-JT/HT CSR 2022-23
352Providing and erecting Heat shrinkable outdoor termination kit for 33 kV ( E )/33 kV (UE) Cross-Linked Polyethylene (Cross-Linked Polyethylene (XLPE)) HT cable 3x300 sq. mm. to 400 sq. mm. with necessary material as per specification no. CB-JT/HT CSR 2022-23
353Providing and erecting Heat shrinkable straight through joint kit for 33 kV ( E )/33 kV (UE) Cross-Linked Polyethylene (Cross-Linked Polyethylene (XLPE)) HT cable 3x300 to 400 sq. mm. with necessary material as per specification no. CB-JT/HT CSR 2022-23
354Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP. CSR 2022-23 CSR 2022-23
355Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI CSR 2022-23
356Supply, Installation, Testing & Commissioning of earthing station using pipe in pipe earthing electrode with complete system as per specs. Including boring, civil work, chamber etc. Earthing shall be carried out as described in IS-3043-1960 code. Pipe in pipe earthing electrode system shall be as per enclosed technical specifications. The entire earthing system should be executed as per system supplier’s instructions. The Earthing Chamber with all the necessary material required for earthing shall be in Contractors scope. Testing of the Earthing system shall be as per specification & results shall be submitted to Engineer-in-Charge duly signed by contractor and authorized representative. 2 meters Length Earthing Electrode
357Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EAEP. CSR 2022-23
358Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. CSR 2022-23
359Supplying and erecting annealed bare copper wire of high purity of required sizes used for earthing on wall with necessary copper clamps fixed on wall/cable/conduit with screws complete. CSR 2022-23
360Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/conduit with screws complete. CSR 2022-23
361Making trench in hard murum/Tar road having 0.9 m depth and minimum 0.3mtr width for laying provided cables of voltage range 3.3 kV to 11 kV complete as per specification No. CW-EXN-CTR CSR 2022-23
362Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete. CSR 2022-23
363Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 Non-Pressure (NP)-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. CSR 2022-23
364Supplying & laying (including excavation) half round reinforced cement concrete pipe of IS 458:2003 Non-Pressure (NP)-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. CSR 2022-23
365Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia, double wall corrugated pipes (DWC) of High-Density Polyethylene.for enclosing cable below ground/road surface, to required depth complete. CSR 2022-23
366Making Horizontal Directional Drill / Bore of 150 mm dia and depth up to 1.5 mtr in soft soil and laying 150 mm High-Density Polyethylene./GI pipe etc. complete as per specification no. CW-EXN-CTR, CSR 2022-23
367Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in Cement concrete foundation and painted complete as per specification no SS-AS/FSG CSR 2022-23
368Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire mesh (jali) complete supported on channel iron, erected in foundation, and painted complete as per specification no SS-AS/DLD, CSR 2022-23
369Supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete CSR 2022-23
370Liaisoning Work for Load Sanction from Electricity power supply authority / board & Electrical inspector or any other government authority for sanction of electrical load. Job involves preparation of necessary documents with drawings, as required for load application, submission of document files with necessary officials / departments, follow-up with all concerned departments for getting required load sanctioned, Obtaining work completion report from Electrical inspector & board officials. Successfully charging of entire installation.DG approval Client (Owner) will make all official payments as per the requirement of Electricity board.
371Liaisoning Work for laying of HT supply cable / Over head 22 KV line from all related corcern authorities / board & Electrical inspector or any other government authority for sanction of cable / over head line routing. Job involves preparation of necessary documents with drawings, as required, submission of document files with necessary officials / departments, follow-up with all concerned departments for obtaining required sanctions, Obtaining work completion report from concerned authorities & board officials. Successfully charging of entire installation. Client (Owner) will make all official payments as per the requirement of concerned authority / board
372Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to Indian Standard: 15652 – 2006 having 2 mm thickness up to 3.3 Kv, CSR 2022-23
373Supplying and fixing PVC synthetic elastomer electrically insulating mat with class C insulation conforming to Indian Standard: 15652 – 2006 tested having 3mm thickness up to 33 Kv, CSR 2022-23
374Supplying shock proof leather safety shoes of electrical grade of standard size as IS :11226, 14544 duly tested, with necessary test certificate from manufacturer. CSR 2022-23
375Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete CSR 2022-23
376Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working up to 22 kV supply complete. CSR 2022-23
377Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes) CSR 2022-23
378Sub work V - Diesel Generating Set & associated work
379Supplying, erecting, testing and commissioning Diesel Generating Set 1500 kVA (Optiprime 750 KVA x 2 Nos) 3 Phase comprising of Engine 901 BHP @ 1500 RPM coupled with Alternator suitable for continuous duty operations rated at 1500 rpm 415 V, 0.8 PF, 50Hz, 3Ph. , mounted on a Base Frame along with:- SYNC Control Panel, Fuel tank, Battery with leads, First fill of oil, Engine safeties & protections, Anti vibration mounting pads, Acoustic Enclosure suitable for 1,500.00 kVA (Optiprime) DG Set. CPCB IV+ Norms.Cost for Silencer Extension with structural support for the DG Set and Piping as per norms shall be included.
380Supplying, erecting, testing and commissioning Diesel Generating Set 1000 kVA (Optiprime 500 KVA x 2 Nos) 3 Phase comprising of Engine 608 BHP @ 1500 RPM coupled with Alternator suitable for continuous duty operations rated at 1500 rpm 415 V, 0.8 PF, 50Hz, 3Ph. , mounted on a Base Frame along with:- SYNC Control Panel, Fuel tank, Battery with leads, First fill of oil, Engine safeties & protections, Anti vibration mounting pads, Acoustic Enclosure suitable for 1,000.00 kVA (Optiprime) DG Set. CPCB IV+ Norms.Cost for Silencer Extension with structural support for the DG Set and Piping as per norms shall be included.
381Supplying, erecting, testing and commissioning Synchronizing panel for above 1000 & 1500 KVA Diesel Generating Set, with necessary accessories, Complete system.
382Referigeration work
383INSULATED PANEL Supply and Erection as per General Technical Specifications , for walls-80 mm thick Polyisocyanurate (PIR) panels, Density: 40 ±2 Kg/m³ 0.5 mm thick Precoated /prepainted G.S. Sheet (min. 180 GSM) or AZ150 PPGL sheet on both sides with polyester coating (thickness: 20~25 micron)
384INSULATED PANEL Supply and Erection as per General Technical Specifications , for walls-100 mm thick PIR panels,Density: 40 ±2Kg / cubic meter 0.5 mm thick Precoated /prepainted G.S. Sheet (min. 180 GSM) or AZ150 PPGL sheet on both sides with polyester coating (thickness: 20~25 micron)
385INSULATED PANEL Supply and Erection as per General Technical Specifications, for ceiling/Walls-60 mm thick PIR panels, Density: 40 ±2 Kg/ cubic meter 0.5 mm thick Precoated /prepainted G.S. Sheet (min. 180 GSM) or AZ150 PPGL on both sides with polyester coating (thickness: 20~25 micron)
386INSULATED PANEL Supply and Erection as per General Technical Specifications, for ceiling-100 mm thick PIR panels, Density: 40 ±2 Kg/cubic meter , 0.5 mm thick Precoated /prepaintedG.S. Sheet (min. 180 GSM) or AZ150 PPGL on both sides with polyester coating (thickness: 20~25 micron)
387INSULATED FLOOR Supply and Erection as per General Technical Specifications Floor 100 mm XPS (in two layers), min 35 Kilogram/cu.m density.Rate for floor insulation to include supply and erection of all ancilliaries including polythene vapour barrier & two ply tarfelt as per specifications and bituminous primer, bitumin / bituminous cold compound for proper adhesion to surfaces.
388Ancillary Materials and Services -Supply and erection of all ancilliaries for floor insulation fixing including polythene vapour barrier & two ply tarfelt as per specifications and bituminous primer, bitumin / bituminous cold compound etc as may be required for proper adhesion to surfaces
389Ancillary Materials and Services - Flashings for Internal and external wall-ceiling joints and wall-wall joints as applicable or as may be required for doors or other openings. The layout showing the chamber dimensions and height is enclosed for ready reference. The flashings should be atleast 50mm x 50 mm or larger sizes with adequate overlap over any given panel-panel joint (Precoated G.S. Sheet, minimum 0.5 mm thick)
390Ancillary Materials and Services -Ceiling support system including supports for hanging/fixing ceiling structure from the roof/slab level to be included. This structure shall be ensured to be with complete thermal break and should avoid metal connection between inside and outside.
391Ancillary Materials and Services - Silicon / Polyeurathene sealant for sealing the gaps between panels and the external / internal face of the insulation panels and any other location as may be deemed suitable for proper insulation panel erection system as applicable.
392Ancillary Materials and Services - PUF/PIR chemical, adhesives,/ tapes / plastic caps / screws etc reqd for onsite application, as may be necessary for a complete and foolproof insulation job.
393Ancillary Materials and Services -Supply, Installation, Testing and commissioning of Pressure relief ports suitable for mounting on insulated panels of various thicknesses (60 mm to 100 mm) with internal heaters for room temperatures ranging from 25 deg C to (-) 10 deg C.(Fermond Soupape 2220 -Valve /Equivalent)
394Ancillary Materials and Services - Making & finishing of cut outs for doors, pipes, cables, pressure ports, ventilatio grills/ diffusers etc as per requirement at site. Finishing would include filling with PUF/PIR & PUF/PIR foam of required density and covering with pre - coated Galvanised ironsheet from both side of the panels to give aesthetically neat joint acceptable to Consultants / Owners. This should also include any additional Silicon sealent or any other material as required.
395Insulated Doors for Pre-cooling chambers, Cold rooms & other areas Manual Sliding type 1800 mm x 2800 mm ht x 80 mm thick PIR , manual typeProviding & fixing of Insulated sliding doors (suitable for fitting on panel structure) of clear opening size & insulation thicknesses as mentioned and specifications as per General technical specifications (GTS). The doors shall be manual single leaf sliding with 0.6 mm thick SS-304 sheet or pre-coated extruded Aluminium of required thickness main frame. The door leaf shall have 0.5 mm thick PCGI /PPGL sheet with min 180 GSM galvanising / S.S sheet cladding on both sides with PIR foam filled In-situ and with a density 40 ± 2 kg/cubic meter (insulation thicknesses as mentioned).0.60mm thick PCGI sheet flashing to protect and reinforce the cut out opening in panel / Civil wall to be included in the cost.The sliding mechanism should be sturdy and smooth in operation complete with rail, runners, sill on the bottom etc. Rail shall be made of heavy duty aluminium alloy / SS with 45º drop & with polyethylene roller / special grade nylon arrangement runner system. The rail shall be provided with canopy / cover of 1.2 mm thick PCGI / Extruded Aluminium of required thickness. interior & exterior door handle, door locak shall be provided.The doors shall have easily replaceable EPDM gaskets to ensure perfect hermetic sealing .
396Insulated Doors for Cold rooms & other areasManual Sliding type 2200 mm x 2800 mm ht x 80 mm thick PIR , manual typeProviding & fixing of Insulated sliding doors (suitable for fitting on panel structure) of clear opening size & insulation thicknesses as mentioned and specifications as per General technical specifications (GTS). The doors shall be manual single leaf sliding with 0.6 mm thick SS-304 sheet or pre-coated extruded Aluminium of required thickness main frame. The door leaf shall have 0.5 mm thick PCGI /PPGL sheet with min 180 GSM galvanising / S.S sheet cladding on both sides with PIR foam filled In-situ and with a density 40 ± 2 Kilogram/cubic meter (insulation thicknesses as mentioned).0.60mm thick PCGI sheet flashing to protect and reinforce the cut out opening in panel / Civil wall to be included in the cost.The sliding mechanism should be sturdy and smooth in operation complete with rail, runners, sill on the bottom etc. Rail shall be made of heavy duty aluminium alloy / SS with 45º drop & with polyethylene roller / special grade nylon arrangement runner system. The rail shall be provided with canopy / cover of 1.2 mm thick PCGI / Extruded Aluminium of required thickness.interior & exterior door handle, door locak shall be provided.The doors shall have easily replaceable EPDM gaskets to ensure perfect heOne Running Meteretic sealing .
397Insulated Doors for Cold rooms & other areasManual Sliding type 1500 mm x 2800 mm ht x 80 mm thick PIR , manual typeProviding & fixing of Insulated sliding doors (suitable for fitting on panel structure) of clear opening size & insulation thicknesses as mentioned and specifications as per General technical specifications (GTS). The doors shall be manual single leaf sliding with 0.6 mm thick SS-304 sheet or pre-coated extruded Aluminium of required thickness main frame. The door leaf shall have 0.5 mm thick PCGI /PPGL sheet with min 180 GSM galvanising / S.S sheet cladding on both sides with PIR foam filled In-situ and with a density 40 ± 2 Kilogram/cubic meter (insulation thicknesses as mentioned).0.60mm thick PCGI sheet flashing to protect and reinforce the cut out opening in panel / Civil wall to be included in the cost.The sliding mechanism should be sturdy and smooth in operation complete with rail, runners, sill on the bottom etc. Rail shall be made of heavy duty aluminium alloy / SS with 45º drop & with polyethylene roller / special grade nylon arrangement runner system. The rail shall be provided with canopy / cover of 1.2 mm thick PCGI / Extruded Aluminium of required thickness.interior & exterior door handle, door locak shall be provided.The doors shall have easily replaceable EPDM gaskets to ensure perfect heOne Running Meteretic sealing .
398Insulated Doors - Swing type with doouble leaf 2000 mm x 2400 mm ht x min 44 mm thick PIR /PUFProviding & fixing of Insulated doors (suitable for fitting on panel /civil structure) mounting of clear opening size & insulation thicknesses as mentioned and specifications as per General technical specifications (GTS). The doors shall be manually operated single leaf swing type with 1.25 mm thick SS-304 sheet or pre-coated extruded Aluminium of required thickness main frame.Any other material for door frame may be considered on case to case basis. The door leaf shall have 0.6 mm thick PCGI sheet with min 180 GSM galvanising / S.S sheet cladding on both sides with PIR/PUF foam filled In-situ and with a density 40 ± 2 Kilogram/cubic meter (insulation thicknesses as mentioned).Viewing window shall be provided.0.60mm thick PCGI sheet flashing to protect and reinforce the cut out opening in panel / Civil wall to be included in the cost.interior & exterior door handle, door locak shall be provided.The rate shall include all minor accessories not specifically mentioned in the technical specification, but essential for the completeness of the work.
399Insulated Doors - Swing type with Single leaf 1200 mm x 2000 mm ht x min 44 mm thick PIR /PUFProviding & fixing of Insulated doors (suitable for fitting on panel /civil structure) mounting of clear opening size & insulation thicknesses as mentioned and specifications as per General technical specifications (GTS). The doors shall be manually operated single leaf swing type with 1.25 mm thick SS-304 sheet or pre-coated extruded Aluminium of required thickness main frame.Any other material for door frame may be considered on case to case basis. The door leaf shall have 0.6 mm thick PCGI sheet with min 180 GSM galvanising / S.S sheet cladding on both sides with PIR/PUF foam filled In-situ and with a density 40 ± 2 Kilogram/cubic meter (insulation thicknesses as mentioned).Viewing window shall be provided.0.60mm thick PCGI sheet flashing to protect and reinforce the cut out opening in panel / Civil wall to be included in the cost.interior & exterior door handle, door locak shall be provided.The rate shall include all minor accessories not specifically mentioned in the technical specification, but essential for the completeness of the work.
400Emergency Exit Fire DoorsProviding & fixing of hollow metal pressed steel FRD Doors made of 18 gauge frames of cross section100X 50& 40mm thk. Flush type door shutters made of 20 gauge sheet with vertical & horizontal channel stiffeners with Min Wool Insulation of suitable density, with2HRS Fire rated As per BS 476 / IS 3614 (With 4 One Number. heavy duty SS ball bearing hinges (welded to hinge jams).With first class workmanship & alignment with a Powder coating finish.Accessories to be included are heavy duty door closer DoOne Running Metera/ eqvt make, SS D Type Handle 600mm long Make DoOne Running Metera/ eqvt, Dead Lock With Cylinder Make DoOne Running Metera/eqvt, Vision Panel With Tuff Glass 200 X 300mm, Tower Bolt, push bar etc as may be required. Color of the door shall be as approved by owners/ architects.Clear opening Size 1200 mm x 2000 mm ht
401Swing type with Single shutter clean room door 1000 mm x 2000 mm ht Supply and Installation of flush doors made of 0.8mm thick 60-80 micron powder coated GI sheets with 30MM frame thickness, 1.2mm thick GPSP powder coated door frames modified to fit within different openings (minimum frame thickness 50MM), with ball bearing hinges, double glazing glass (400MM X 600MM) and hardware like SS D-Handle, concealed tower bolt for the double door, both side operated dead lock and key.The toilet doors shall be fitted with 600mm wide x 300mm high Grill at botom portion in Al powder coated / SS construction in finish acceptable to owners/architect.0.60mm thick PCGI sheet flashing to protect and reinforce the cut out opening in panel / Civil wall to be included in the cost.
402High Speed Rollup Door Automatic: Modular Section Non tearcurtain of Polyester fabric PVC coated of thickness 1.3 mm withSafety features, Push Button Operation. Transparent See throughSection. 2200mm x 2800mm ht clear opening size
403High Speed Rollup Door Automatic: Modular Section Non tearcurtain of Polyester fabric PVC coated of thickness 1.3 mm withSafety features, Push Button Operation. Transparent See throughSection. 1500mm x 2800mm ht clear opening size
404Strip Curtains: Supply, Installation, Testing and commissioning of strip curtains made of 3 mm thick transparent PVC sheet strips with 40 / 50 mm overlapping and supporting clamps. The strips shall have free swinging motion. The strip material shall be suitable for the specified low temperature application to ensure that it remains soft even at the lowest operating temperature.Suitable for Clear door opening size: 1800mm x 2800mm ht
405Strip Curtains: Supply, Installation, Testing and commissioning of strip curtains made of 3 mm thick transparent PVC sheet strips with 40 / 50 mm overlapping and supporting clamps. The strips shall have free swinging motion. The strip material shall be suitable for the specified low temperature application to ensure that it remains soft even at the lowest operating temperature.Suitable for Clear door opening size: 1500mm x 2800mm ht
406Strip Curtains: Supply, Installation, Testing and commissioning of strip curtains made of 3 mm thick transparent PVC sheet strips with 40 / 50 mm overlapping and supporting clamps. The strips shall have free swinging motion. The strip material shall be suitable for the specified low temperature application to ensure that it remains soft even at the lowest operating temperature.Suitable for Clear door opening size: 2200mm x 2800mm ht
407Strip Curtains: Supply, Installation, Testing and commissioning of strip curtains made of 3 mm thick transparent PVC sheet strips with 40 / 50 mm overlapping and supporting clamps. The strips shall have free swinging motion. The strip material shall be suitable for the specified low temperature application to ensure that it remains soft even at the lowest operating temperature.Suitable for Clear door opening size: 1200mm x 2000mm ht
408DOCK DOOR Supply, Installation, Testing and commissioning of Dock door,ovehead sectional door, vertically moving with motorized movement. The shutter be made of pre-coated steel sandwich panels 40mm thick injected with PIR / PUF foam (density 40 ± 2 Kilogram/cubic meter) & clear opening size as specified. Steel external / internal facing shall have white paint (RAL9002)/ Equivalent. However, Door Colour shade shall be discussed & finalised in consultation with owner & Architect.Double glazing vision panels are made from high quality engineered plastic frame in transparent scratch resistant acrylic or equivalent material shall be provided. The bottom of the door has rubber gasket to seal from bottom without any gap. The vertical moving track shall be U shaped made of 2.5 mm G.S. Sheets. The dock door shall have excellent Resistance to water penetration & resistance to wind load and water peOne Running Metereability properties.The dock door shall have lift system (Normal Lift / High Lift / Vertical Lift) as per the site condition.Safety features like spring break safety device, slack cable safety device, cable break safety device, bottom safety edge etc shall be provided. These overhead doors will be operated by electric motor and shall have provision of operating manually by using a chain hoist. The electrical motor used shall be high quality & durable motor (CE marked) with IP54 (min) protection Class. Accessories for easy operation doors including Push button /Remote Control/ Pull cord shall be provided.Clear opening size: 2400 mm width x 3000 mm height
409DOCK LEVELER Supply, Installation, Testing and commissioning of dock leveller, Designed for Hydraulic operation in accordance of EN:1398 in steel construction as per General technical specification ,Acceptable makes: Gandhi Automation/ Metaflex Size : 2000mm width and 2500mm deep, Capacity: 6 MT dynamic loadingLift height min 400 mm from centre level, upwards & downwards., Main cylinders-2 One Number,1- Hinged leap cylinder, All controls, control panels, controller with IP65 protection housing, power and control cabling, pair of Plinth protection high density EPDM bumpers, two One Number for each as required for full operation to be included.
410Dock SealCUSHION type suitable for heavy duty operations for door opening size as above. .Flexible polyurethane foam, covered with PVC / polyester fabric, supporting the vehicle pressures and perfectly sealing the three sides.
411AIR COOLED CONDENSING UNITS For Cold Storage 1- Irradiation untreated area (General details as per REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make SEMI-HERMETIC compressor working on R134A / R407C, Air cooled condenser, Liquid receiver,Oil separator with check valve in discharge line, Base frame for mounting, H.P. / L.P.switches, Suction accumulator Vibration eliminator, Oil pr switch and pressure gauges , Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required.Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature.It is also noted that the unit may work at higher temperature evaporation >7 deg C, condenser & refrigerant shall be selected accordingly.Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows :Capacity: 19 KWDesign Temperature: (-)4 deg. C evap. Maximum ambient Temperature: 40 deg C ambientMinimum fin spacing: 2 mm
412AIR COOLING UNITS - Air Cooling Units for Cold Storage 1- Irradiation Untreated Area (General details as per REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Luve / Guentner / Thermofin /eqvt approvedType of Unit -Single / Twin: Single coil typeType of Refrigerant feed: HFC - DXCapacity - kW: 19Evap. Temp. & TD ‘C’: (-)4 °C / 4°CCoil / Fin MOC: Cu / AlFin spacing -mm: 6 mmFin type: PlateFinned coil length -m: To be MentionedTotal fan capacity of each unit– CMH: 21700External sp. Wg, mm: 3No of Fans/Unit: 3Fan Motor -kW each: To be MentionedAir throw -m:10 mDrain pan insulation: RequiredDrain pan heating: Not requiredType of Defrosting: electricalFan peripheral heating: Not requiredSuitable Supporting structure from primary support at roof level or mounting stand (if supporting from floor level) to be considered in the costing as well.
413Refrigeration Piping, Fittings & Valves for Cold Storage 1, Irradiation untreated area(General details as per REFRIGERATION SYSTEM of GTS) The piping shall be of refrigeration quality The piping shall be of refrigeration quality seamless copper tubes and the valves shall be brassomatic / Henry or equivalent make. The piping shall be included accessories such as filter, drier, sight glass, heat exchanger, suction lineaccumulator etc. as per P & I diagram approved by Consultant. Adequate number of supports shall be included. The piping shall be supported at distances of maximum 1.5 m from each other with suitably placed GS threaded rods of minimum 6 mm thickness when outside the chamber and piping shall be run on cable trays of size suitable to fit the pipes including insulation. Common cable trays can be considered depending on the suitability at site, however the same shall be acceptable to the consultant / owner. Overall, the piping execution shall ensure proper workmanship and a neat and tidy work is expected with straight horizontal and vertical lines and proper supporting. Under no circumstances shall any additional charges be demanded by the contractor for ensuring the same.The suction and discharge lines shall be designed for a maximum pressure drop corresponding to 1.1 deg. C drop in saturated evaporating and condensing temperatures. The liquid line shall be designed for maximum pressure drop corresponding to a drop 0.5 to 1 deg. C in saturation temperature. The piping shall be designed with proper slope in the direction of Refrigerant flow and to ensure proper oil return to the compressor and should be installed with adequate supports to avoid undue vibration. The piping should be thoroughly cleaned as per standard practice prior to installation.Refrigeration piping,fittings,valves,interconnecting condensing & evaporator unit complete with standard controls & accessories, supports as may be required shall be included in cost.layout drawing showing proposed location of condesing units is atttached for your reference. upto 15 m piping (1m= 1m suction + 1m liquid) per unit considered in the item costing.
414Suction line insulation for Cold Storage 1- Irradiation untreated area (General details as per REFRIGERATION SYSTEM of GTS) Suction line insulation with EPDM/ Cross-Linked Polyethylene (Cross-Linked Polyethylene (XLPE))/Equivalent insulation with minimum 28G Aluminium foil Clading in the covered areas and Weatherproof Clading in areas exposed to sunlight and is uncovered ; e.g. Woven glass cloth with epoxy coating or Armacheck GC/equivalent Clading with suitable fittings and Adhesives.Alternatively,Fevicol Weather protect coat applied as per manufacturers recommandation may be used for entire insulation protection. Insulation supports shall be half round or full round heavy duty PVC pipe sections of relevant size which shall be atleast 150 milimeter in length and shall be placed below every support (if necessary). This is essentially ensuring that the insulation compression at the support is at the minimum. Thickness - 25milimeter
415Drain piping for Cold Storage 1- Irradiation untreated area with rigid U-PVC pipe from A.C. units to to suitable drain point complete with 'U' Traps for each cold room and supports.Drain lines (inside the chambers) to have 10 mm EPDM / Eqvt. insulation with factory backed Aluminium foil.Individiual Drain outlet line from ACU pipe size shall be same as the drain outlet of ACU and further the header shall be at least one size higher than the drain outlet connection size. Further, higher sizes may be considered as per the consultants/owner's recommendation
416Controls and Instruments for Cold Storage 1 Irradiation untreated area(a) Thermostatic expansion valves for each Air condensing units(b) Digital temperature indicator cum controllers (0 to 50 deg. C range) (c) Liquid line solenoid valves, DANFOSS / SPORLAN /EQVT make (d) Digital temperature cum RH indicator (minus 20 to 50 deg. C range), for A.C. units to be placed outside the each cold rooms for each chamber.
417First charge refrigeration gas and oil etc. as required upto commissioning and final handling over of plant. for Cold Storage 1- Irradiation untreated area ref. system
418Painting of equipment/piping / piping supports etc. as per standard colour codes with initial coat of red oxide primer and two coats of synthetic enamel paint for Cold Storage 1 Irradiation untreated area ref. system
419Electrical work for Refrigeration System for Cold Storage 1- Irradiation untreated area ref. systemElectrical control panel shall be manufactured as per specifications menioned in GTS and approved GA drawings.The Panel shall be comprising of following: a) Suitable Incomer of ACB / MCCB / MCB / RCBO of required rating and as per enclosed specification and approval. b) All Suitable rating MCB's, MPCB's, RCBO's, starters, relays, etc for various motors as used in the equipments shall be selected as per type 2 co ordination chart provided by the manufacturer. c) MCBs for control circuit d) Each starter shall be provided with facility for remote Start/Stop operation.This panel shall be located in the plant room (on terrace level) and shal have weather proof enclosure with suitable MCB's/RCCB's/RCBO's near the condensing unit. Job includes Electrical Power cabling (armoured) to all the outgoing feeders along with PVC medium duty Conduit/ pregalvanised Cable tray's, etc as per requirement and power cabling shall be as per specifications given in GTS.Control wiring with PVC insulated copper conductor with conduits as required for the refrigeration and other systems as defined here.Local Protection through MCB's/RCCB's/RCBO's for A.C. units, fan motors and other remotely located motors shall be part of the job.The Job shall also include earthing for control panel and various motors etc. using required sizes earthing conductors using GI/Cu earthing strips or Cu Conductors, all as per IS.The control panel shall have provision for interlocking of various equipment as per standard practice. Single electrical supply will be provided for the ref. panel further distribution shall be considered in refrigeration system
420Miscellaneous Items for Cold Storage 1 Irradiation untreated area ref. systema) Vibration isolators for condensing units, supporting rods / Frame for A.C. Units with insulation, steel structure for mouting condensing units etc. as may be required b) Minor structural openings in walls / panels etc for piping, cabling etc. and finishing.
421Charges for Installation, Testing and Commissioning for Cold Storage 1- Irradiation untreated area ref. systemInstallation, testing and commissioning of all above equipment / material as per the system requirement. All tools and tackles, welding machines, welding rods and gases etc. required for fabrication, erection, testing and commissioning shall be arranged by the contractor at his cost. The plant shall be erected, tested, commissioned as per Consultant's approved drawings / specifications and instructions to his and Employer's satisfaction. The refrigeration system shall be pressure tested and evacuated as per standard practice before charging the refrigerant. The water lines shall also be pressure tested as per standard practice. The plant shall be run for a period of three days after commoissioning by the contractor, to assess the plant performance. The contractor shall provide 3 hard copies of operation & maintenance for the plant along with as built drawings. The contractor shall also arrange the training of the operating staff for proper operation & maintenance of the plant (included in above rates)
422Refrigeration System for Cold Storage 3, 4- Irradiation treated area
423AIR COOLED CONDENSING UNITS For Cold Storage 3- Irradiation treated area (General details as per REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make SEMI-HERMETIC compressor working on R134A / R407C, Air cooled condenser, Liquid receiver,Oil separator with check valve in discharge line, Base frame for mounting, H.P. / L.P.switches, Suction accumulator Vibration eliminator, Oil pr switch and pressure gauges , Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required.Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. It is also noted that the unit may work at higher temperature evaporation >7 deg C, condenser & refrigerant shall be selected accordingly.Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows :Capacity: 14 KWDesign Temperature: (-)4 deg. C evap. Maximum ambient Temperature: 40 deg C ambientMinimum fin spacing: 2 mm
424AIR COOLED CONDENSING UNITS for Cold Storage 4- Irradiation treated area(General details as per REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make SEMI-HERMETIC compressor working on R134A / R407C, Air cooled condenser, Liquid receiver,Oil separator with check valve in discharge line, Base frame for mounting, H.P. / L.P.switches, Suction accumulator Vibration eliminator, Oil pr switch and pressure gauges , Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required.Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature.It is also noted that the unit may work at higher temperature evaporation >7 deg C, condenser & refrigerant shall be selected accordingly.Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows :Capacity: 11 KWDesign Temperature: (-)4 deg. C evap. Maximum ambient Temperature: 40 deg C ambientMinimum fin spacing: 2 mm
425AIR COOLING UNITS - Air Cooling Units for Cold Storage 3- Irradiation treated area (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Luve / Guentner / Thermofin /eqvt approvedType of Unit -Single / Twin: Single coil typeType of Refrigerant feed: HFC - DXCapacity - kW: 14Evap. Temp. & TD ‘C’: (-)4 °C / 4°CCoil / Fin MOC: Cu / AlFin spacing -mm: 6 mmFin type: PlateFinned coil length -m: To be MentionedTotal fan capacity of each unit– CMH: 16200External sp. Wg, mm: 6No of Fans/Unit: 2/3Fan Motor -kW each: To be MentionedAir throw -m: 10 mDrain pan insulation: RequiredDrain pan heating: Not requiredType of Defrosting: ElectricalFan peripheral heating: Not requiredSuitable Supporting structure from primary support at roof level or mounting stand (if supporting from floor level) to be considered in the costing as well.
426AIR COOLING UNITS - Air Cooling Units Cold Storage 4- Irradiation treated area(General details as per REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Luve / Guentner / Thermofin /eqvt approvedType of Unit -Single / Twin: Single coil typeType of Refrigerant feed: HFC - DXCapacity - kW: 11Evap. Temp. & TD ‘C’: (-)4 °C / 4°CCoil / Fin MOC: Cu / AlFin spacing -mm: 6 mmFin type: PlateFinned coil length -m: To be MentionedTotal fan capacity of each unit– CMH: 12500External sp. Wg, mm: 3No of Fans/Unit: 2/3Fan Motor -kW each: To be MentionedAir throw -m:10 mDrain pan insulation: RequiredDrain pan heating: Not requiredType of Defrosting: electricalFan peripheral heating: Not requiredSuitable Supporting structure from primary support at roof level or mounting stand (if supporting from floor level) to be considered in the costing as well.
427Refrigeration Piping, Fittings & Valves for Cold Storage 3,4- Irradiation treated area ref system (General details as per REFRIGERATION SYSTEM of GTS) The piping shall be of refrigeration quality The piping shall be of refrigeration quality seamless copper tubes and the valves shall be brassomatic / Henry or equivalent make. The piping shall be included accessories such as filter, drier, sight glass, heat exchanger, suction lineaccumulator etc. as per P & I diagram approved by Consultant. Adequate number of supports shall be included. The piping shall be supported at distances of maximum 1.5 m from each other with suitably placed GS threaded rods of minimum 6 mm thickness when outside the chamber and piping shall be run on cable trays of size suitable to fit the pipes including insulation. Common cable trays can be considered depending on the suitability at site, however the same shall be acceptable to the consultant / owner. Overall, the piping execution shall ensure proper workmanship and a neat and tidy work is expected with straight horizontal and vertical lines and proper supporting. Under no circumstances shall any additional charges be demanded by the contractor for ensuring the same.The suction and discharge lines shall be designed for a maximum pressure drop corresponding to 1.1 deg. C drop in saturated evaporating and condensing temperatures. The liquid line shall be designed for maximum pressure drop corresponding to a drop 0.5 to 1 deg. C in saturation temperature. The piping shall be designed with proper slope in the direction of Refrigerant flow and to ensure proper oil return to the compressor and should be installed with adequate supports to avoid undue vibration. The piping should be thoroughly cleaned as per standard practice prior to installation.Refrigeration piping,fittings,valves,interconnecting condensing & evaporator unit complete with standard controls & accessories, supports as may be required shall be included in cost.layout drawing showing proposed location of condesing units is atttached for your reference.upto 15 m piping (1m= 1m suction + 1m liquid) per unit considered in the item costing.
428Suction line insulation for Cold Storage 3,4- Irradiation treated area ref system (General details as per REFRIGERATION SYSTEM of GTS) Suction line insulation with EPDM/ Cross-Linked Polyethylene (Cross-Linked Polyethylene (XLPE))/Equivalent insulation with minimum 28G Aluminium foil Clading in the covered areas and Weatherproof Clading in areas exposed to sunlight and is uncovered ; e.g. Woven glass cloth with epoxy coating or Armacheck GC/equivalent Clading with suitable fittings and Adhesives.Alternatively,Fevicol Weather protect coat applied as per manufacturers recommendation may be used for entire insulation protection. Insulation supports shall be half round or full round heavy duty PVC pipe sections of relevant size which shall be atleast 150 mm in length and shall be placed below every support (if necessary). This is essentially ensuring that the insulation compression at the support is at the minimum. Thickness - 25mm
429Drain piping for Cold Storage 3- Irradiation treated area ref system with rigid U-PVC pipe from A.C. units to to suitable drain point complete with 'U' Traps for each cold room and supports.Drain lines (inside the chambers) to have 10 mm EPDM / Eqvt. insulation with factory backed Aluminium foil.Individiual Drain outlet line from ACU pipe size shall be same as the drain outlet of ACU and further the header shall be at least one size higher than the drain outlet connection size. Further, higher sizes may be considered as per the consultants/owner's recommendation
430Controls and Instruments for Cold Storage 3,4- Irradiation treated area ref system(a) Thermostatic expansion valves for each Air condensing units(b) Digital temperature indicator cum controllers (0 to 50 deg. C range) (c) Liquid line solenoid valves, DANFOSS / SPORLAN /EQVT make (d) Digital temperature cum RH indicator (minus 20 to 50 deg. C range), for A.C. units to be placed outside the each cold rooms for each chamber.
431First charge refrigeration gas and oil etc. as required upto commissioning and final handling over of plant. for Cold Storage 3,4- Irradiation treated area ref system
432Painting of equipment/piping / piping supports etc. as per standard colour codes with initial coat of red oxide primer and two coats of synthetic enamel paint for Cold Storage 3,4- Irradiation treated area ref system
433Electrical work for Refrigeration System for Cold Storage 3,4- Irradiation treated area ref systemElectrical control panel shall be manufactured as per specifications menioned in GTS and approved GA drawings.The Panel shall be comprising of following: a) Suitable Incomer of ACB / MCCB / MCB / RCBO of required rating and as per enclosed specification and approval. b) All Suitable rating MCB's, MPCB's, RCBO's, starters, relays, etc for various motors as used in the equipments shall be selected as per type 2 co ordination chart provided by the manufacturer. c) MCBs for control circuit d) Each starter shall be provided with facility for remote Start/Stop operation.This panel shall be located in the plant room (on terrace level) and shal have weather proof enclosure with suitable MCB's/RCCB's/RCBO's near the condensing unit. Job includes Electrical Power cabling (armoured) to all the outgoing feeders along with PVC medium duty Conduit/ pregalvanised Cable tray's, etc as per requirement and power cabling shall be as per specifications given in GTS.Control wiring with PVC insulated copper conductor with conduits as required for the refrigeration and other systems as defined here.Local Protection through MCB's/RCCB's/RCBO's for A.C. units, fan motors and other remotely located motors shall be part of the job.The Job shall also include earthing for control panel and various motors etc. using required sizes earthing conductors using GI/Cu earthing strips or Cu Conductors, all as per IS.The control panel shall have provision for interlocking of various equipment as per standard practice. Single electrical supply will be provided for the ref. panel further distribution shall be considered in refrigeration system
434Miscellaneous Items for Cold Storage 3,4- Irradiation treated area ref systema) Vibration isolators for condensing units, supporting rods / Frame for A.C. Units with insulation, steel structure for mouting condensing units etc. as may be required b) Minor structural openings in walls / panels etc for piping, cabling etc. and finishing.
435Charges for Installation, Testing and Commissioning for Cold Storage 3,4- Irradiation treated area ref systemInstallation, testing and commissioning of all above equipment / material as per the system requirement. All tools and tackles, welding machines, welding rods and gases etc. required for fabrication, erection, testing and commissioning shall be arranged by the contractor at his cost. The plant shall be erected, tested, commissioned as per Consultant's approved drawings / specifications and instructions to his and Employer's satisfaction. The refrigeration system shall be pressure tested and evacuated as per standard practice before charging the refrigerant. The water lines shall also be pressure tested as per standard practice. The plant shall be run for a period of three days after commoissioning by the contractor, to assess the plant performance. The contractor shall provide 3 hard copies of operation & maintenance for the plant along with as built drawings. The contractor shall also arrange the training of the operating staff for proper operation & maintenance of the plant (included in above rates)
436AIR COOLED CONDENSING UNITS For Pre-cooling 1 & 2- Irradiation treated area (General details as per REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make SEMI-HERMETIC compressor working on R134A / R407C, Air cooled condenser, Liquid receiver,Oil separator with check valve in discharge line, Base frame for mounting, H.P. / L.P.switches, Suction accumulator Vibration eliminator, Oil pr switch and pressure gauges , Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required.Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. It is also noted that the unit may work at higher temperature evaporation >7 deg C, condenser & refrigerant shall be selected accordingly.Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows :Capacity: 26 KWDesign Temperature: (-)4 deg. C evap. Maximum ambient Temperature: 40 deg C ambientMinimum fin spacing: 2 mm
437AIR COOLED CONDENSING UNITS For Cold Storage 1- Irradiation treated area (General details as per REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make SEMI-HERMETIC compressor working on R134A / R407C, Air cooled condenser, Liquid receiver,Oil separator with check valve in discharge line, Base frame for mounting, H.P. / L.P.switches, Suction accumulator Vibration eliminator, Oil pr switch and pressure gauges , Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required.Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. It is also noted that the unit may work at higher temperature evaporation >7 deg C, condenser & refrigerant shall be selected accordingly.Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows :Capacity: 17.5 KWDesign Temperature: (-)4 deg. C evap. Maximum ambient Temperature: 40 deg C ambientMinimum fin spacing: 2 mm
438AIR COOLED CONDENSING UNITS for Cold Storage 2- Irradiation treated area(General details as per REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make SEMI-HERMETIC compressor working on R134A / R407C, Air cooled condenser, Liquid receiver,Oil separator with check valve in discharge line, Base frame for mounting, H.P. / L.P.switches, Suction accumulator Vibration eliminator, Oil pr switch and pressure gauges , Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required.Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature.It is also noted that the unit may work at higher temperature evaporation >7 deg C, condenser & refrigerant shall be selected accordingly.Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows :Capacity: 14 KWDesign Temperature: (-)4 deg. C evap. Maximum ambient Temperature: 40 deg C ambientMinimum fin spacing: 2 mm
439AIR COOLING UNITS - Air Cooling Units for Pre-cooling chamber 1,2 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / Alfa Luve / Guentner /Thermofin / Eqvt, Model: To be MentionedType of Unit -Single / Twin: Twin coil type,Type of Refrigerant feed: HFC - DXCapacity - kW: 52, Evap. Temp. & TD ‘C’: (-)4 °C / 4 °CCoil / Fin MOC: Cu / Al, Fin spacing -mm: 6 mmFin type: Plate, Finned coil length -m: To be MentionedTotal fan capacity of each unit– CMH: 53500, External sp. Wg, mm: 25No of Fans/Unit: 3/4, Fan Motor -kW each: To be MentionedAir throw -m: 11 m, Drain pan insulation: RequiredDrain pan heating: Not requiredType of Defrosting: ElectricalFan peripheral heating: Not requiredSuitable Supporting structure from primary support at roof level or mounting stand (if supporting from floor level) to be considered in the costing as well.Product Covering Flap - Suitable product covering flap made of PVC sheet / EQVT sturdy material to be mounted on the unit above the fan(s) to ensure proper air flow through the produce. There shall be suitable reinforcement inside the flap as well as at the ends for supporting the Flap. Costing for the same also shall be included.It must be noted that this scheme is considered as a part of a combined pre-cooling system which will have an airtight plenum created between the wall panel and the area around the ACU as defined above. So while the insulated panel will be billed as per the the insulation panel rates, the cutting for the panel, the flashings, etc as needed for the pre-cooling unit arrangement should be considered while quoting the cost of panels.
440AIR COOLING UNITS - Air Cooling Units Cold Storage 2- Irradiation treated area(General details as per REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Luve / Guentner / Thermofin /eqvt approvedType of Unit -Single / Twin: Single coil typeType of Refrigerant feed: HFC - DXCapacity - kW: 14Evap. Temp. & TD ‘C’: (-)4 °C / 4°CCoil / Fin MOC: Cu / AlFin spacing -mm: 6 mmFin type: PlateFinned coil length -m: To be MentionedTotal fan capacity of each unit– CMH: 16200External sp. Wg, mm: 3No of Fans/Unit: 2/3Fan Motor -kW each: To be MentionedAir throw -m:10 mDrain pan insulation: RequiredDrain pan heating: Not requiredType of Defrosting: electricalFan peripheral heating: Not requiredSuitable Supporting structure from primary support at roof level or mounting stand (if supporting from floor level) to be considered in the costing as well.
441Refrigeration Piping, Fittings & Valves for Pre-cooling 1 & 2,Cold Storage 1, 2- Irradiation treated area (General details as per REFRIGERATION SYSTEM of GTS) The piping shall be of refrigeration quality The piping shall be of refrigeration quality seamless copper tubes and the valves shall be brassomatic / Henry or equivalent make. The piping shall be included accessories such as filter, drier, sight glass, heat exchanger, suction lineaccumulator etc. as per P & I diagram approved by Consultant. Adequate number of supports shall be included. The piping shall be supported at distances of maximum 1.5 m from each other with suitably placed GS threaded rods of minimum 6 mm thickness when outside the chamber and piping shall be run on cable trays of size suitable to fit the pipes including insulation. Common cable trays can be considered depending on the suitability at site, however the same shall be acceptable to the consultant / owner. Overall, the piping execution shall ensure proper workmanship and a neat and tidy work is expected with straight horizontal and vertical lines and proper supporting. Under no circumstances shall any additional charges be demanded by the contractor for ensuring the same.The suction and discharge lines shall be designed for a maximum pressure drop corresponding to 1.1 deg. C drop in saturated evaporating and condensing temperatures. The liquid line shall be designed for maximum pressure drop corresponding to a drop 0.5 to 1 deg. C in saturation temperature. The piping shall be designed with proper slope in the direction of Refrigerant flow and to ensure proper oil return to the compressor and should be installed with adequate supports to avoid undue vibration. The piping should be thoroughly cleaned as per standard practice prior to installation.Refrigeration piping,fittings,valves,interconnecting condensing & evaporator unit complete with standard controls & accessories, supports as may be required shall be included in cost.layout drawing showing proposed location of condesing units is atttached for your reference. upto 15 m piping (1m= 1m suction + 1m liquid) per unit considered in the item costing.
442Suction line insulation for Pre-cooling 1 & 2,Cold Storage 1, 2- Irradiation treated area(General details as per REFRIGERATION SYSTEM of GTS) Suction line insulation with EPDM/ Cross-Linked Polyethylene (Cross-Linked Polyethylene (XLPE))/Equivalent insulation with minimum 28G Aluminium foil Clading in the covered areas and Weatherproof Clading in areas exposed to sunlight and is uncovered ; e.g. Woven glass cloth with epoxy coating or armacheck GC/equivalent Clading with suitable fittings and Adhesives.Alternatively,Fevicol Weather protect coat applied as per manufacturers recommendation may be used for entire insulation protection. Insulation supports shall be half round or full round heavy duty PVC pipe sections of relevant size which shall be atleast 150 mm in length and shall be placed below every support (if necessary). This is essentially ensuring that the insulation compression at the support is at the minimum. Thickness - 25mm
443Drain piping for Pre-cooling 1 & 2,Cold Storage 1, 2- Irradiation treated area ref system with rigid U-PVC pipe from A.C. units to to suitable drain point complete with 'U' Traps for each cold room and supports.Drain lines (inside the chambers) to have 10 mm EPDM / Eqvt. insulation with factory backed Aluminium foil.Individiual Drain outlet line from ACU pipe size shall be same as the drain outlet of ACU and further the header shall be at least one size higher than the drain outlet connection size. Further, higher sizes may be considered as per the consultants/owner's recommendation
444Controls and Instruments for Pre-cooling 1 & 2,Cold Storage 1, 2- Irradiation treated area ref system (a) Thermostatic expansion valves for each Air condensing units(b) Digital temperature indicator cum controllers (0 to 50 deg. C range) (c) Liquid line solenoid valves, DANFOSS / SPORLAN /EQVT make (d) Digital temperature cum RH indicator (minus 20 to 50 deg. C range), for A.C. units to be placed outside the each cold rooms for each chamber.
445First charge refrigeration gas and oil etc. as required upto commissioning and final handling over of plant. for Pre-cooling 1 & 2,Cold Storage 1, 2- Irradiation treated area ref system
446Painting of equipment/piping / piping supports etc. as per standard colour codes with initial coat of red oxide primer and two coats of synthetic enamel paint for Pre-cooling 1 & 2,Cold Storage 1, 2- Irradiation treated area ref system
447Electrical work for Refrigeration System for Pre-cooling 1 & 2,Cold Storage 1, 2- Irradiation treated area ref system Electrical control panel shall be manufactured as per specifications menioned in GTS and approved GA drawings.The Panel shall be comprising of following: a) Suitable Incomer of ACB / MCCB / MCB / RCBO of required rating and as per enclosed specification and approval. b) All Suitable rating MCB's, MPCB's, RCBO's, starters, relays, etc for various motors as used in the equipments shall be selected as per type 2 co ordination chart provided by the manufacturer. c) MCBs for control circuit d) Each starter shall be provided with facility for remote Start/Stop operation.This panel shall be located in the plant room (on terrace level) and shal have weather proof enclosure with suitable MCB's/RCCB's/RCBO's near the condensing unit. Job includes Electrical Power cabling (armoured) to all the outgoing feeders along with PVC medium duty Conduit/ pregalvanised Cable tray's, etc as per requirement and power cabling shall be as per specifications given in GTS.Control wiring with PVC insulated copper conductor with conduits as required for the refrigeration and other systems as defined here.Local Protection through MCB's/RCCB's/RCBO's for A.C. units, fan motors and other remotely located motors shall be part of the job.The Job shall also include earthing for control panel and various motors etc. using required sizes earthing conductors using GI/Cu earthing strips or Cu Conductors, all as per IS.The control panel shall have provision for interlocking of various equipment as per standard practice. Single electrical supply will be provided for the ref. panel further distribution shall be considered in refrigeration system
448Miscellaneous Items for Pre-cooling 1 & 2,Cold Storage 1, 2- Irradiation treated area ref system a) Vibration isolators for condensing units, supporting rods / Frame for A.C. Units with insulation, steel structure for mouting condensing units etc. as may be required b) Minor structural openings in walls / panels etc for piping, cabling etc. and finishing.
449Charges for Installation, Testing and Commissioning for Pre-cooling 1 & 2,Cold Storage 1, 2- Irradiation treated area ref system Installation, testing and commissioning of all above equipment / material as per the system requirement. All tools and tackles, welding machines, welding rods and gases etc. required for fabrication, erection, testing and commissioning shall be arranged by the contractor at his cost. The plant shall be erected, tested, commissioned as per Consultant's approved drawings / specifications and instructions to his and Employer's satisfaction. The refrigeration system shall be pressure tested and evacuated as per standard practice before charging the refrigerant. The water lines shall also be pressure tested as per standard practice. The plant shall be run for a period of three days after commoissioning by the contractor, to assess the plant performance. The contractor shall provide 3 hard copies of operation & maintenance for the plant along with as built drawings. The contractor shall also arrange the training of the operating staff for proper operation & maintenance of the plant (included in above rates)
450AIR COOLED CONDENSING UNITS For Pre-cooling 1 & 2- VHT Ground Floor (General details as per REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make SEMI-HERMETIC compressor working on R134A / R407C, Air cooled condenser, Liquid receiver,Oil separator with check valve in discharge line, Base frame for mounting, H.P. / L.P.switches, Suction accumulator Vibration eliminator, Oil pr switch and pressure gauges , Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required.Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. It is also noted that the unit may work at higher temperature evaporation >7 deg C, condenser & refrigerant shall be selected accordingly.Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows :Capacity: 30 KWDesign Temperature: (-)4 deg. C evap. Maximum ambient Temperature: 40 deg C ambientMinimum fin spacing: 2 mm
451AIR COOLED CONDENSING UNITS For Cold Storage 1- VHT Ground Floor (General details as per REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make SEMI-HERMETIC compressor working on R134A / R407C, Air cooled condenser, Liquid receiver,Oil separator with check valve in discharge line, Base frame for mounting, H.P. / L.P.switches, Suction accumulator Vibration eliminator, Oil pr switch and pressure gauges , Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required.Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. It is also noted that the unit may work at higher temperature evaporation >7 deg C, condenser & refrigerant shall be selected accordingly.Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows :Capacity: 19 KWDesign Temperature: (-)4 deg. C evap. Maximum ambient Temperature: 40 deg C ambientMinimum fin spacing: 2 mm
452AIR COOLED CONDENSING UNITS for Cold Storage 2,3- VHT Ground Floor(General details as per REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make SEMI-HERMETIC compressor working on R134A / R407C, Air cooled condenser, Liquid receiver,Oil separator with check valve in discharge line, Base frame for mounting, H.P. / L.P.switches, Suction accumulator Vibration eliminator, Oil pr switch and pressure gauges , Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required.Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature.It is also noted that the unit may work at higher temperature evaporation >7 deg C, condenser & refrigerant shall be selected accordingly.Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows :Capacity: 14 KWDesign Temperature: (-)4 deg. C evap. Maximum ambient Temperature: 40 deg C ambientMinimum fin spacing: 2 mm
453AIR COOLED CONDENSING UNITS for VHT Post Cooling Chamber- VHT Ground Floor(General details as per REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make SEMI-HERMETIC compressor working on R134A / R407C, Air cooled condenser, Liquid receiver,Oil separator with check valve in discharge line, Base frame for mounting, H.P. / L.P.switches, Suction accumulator Vibration eliminator, Oil pr switch and pressure gauges , Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required.Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature.It is also noted that the unit may work at higher temperature evaporation >7 deg C, condenser & refrigerant shall be selected accordingly.Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows :Capacity: 20 KWDesign Temperature: 4 deg. C evap. Maximum ambient Temperature: 40 deg C ambientMinimum fin spacing: 2 mm
454AIR COOLING UNITS - Air Cooling Units for Pre-cooling chamber 1,2- VHT Ground Floor (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / Alfa Luve / Guentner /Thermofin / Eqvt, Model: To be MentionedType of Unit -Single / Twin: Twin coil type,Type of Refrigerant feed: HFC - DXCapacity -60 kW: , Evap. Temp. & TD ‘C’: (-)4 °C / 4 °CCoil / Fin MOC: Cu / Al, Fin spacing -mm: 6 mmFin type: Plate, Finned coil length -m: To be MentionedTotal fan capacity of each unit– CMH: 62000, External sp. Wg, mm: 25No of Fans/Unit: 3/4, Fan Motor -kW each: To be MentionedAir throw -m: 8 m, Drain pan insulation: RequiredDrain pan heating: Not requiredType of Defrosting: ElectricalFan peripheral heating: Not requiredSuitable Supporting structure from primary support at roof level or mounting stand (if supporting from floor level) to be considered in the costing as well.Product Covering Flap - Suitable product covering flap made of PVC sheet / EQVT sturdy material to be mounted on the unit above the fan(s) to ensure proper air flow through the produce. There shall be suitable reinforcement inside the flap as well as at the ends for supporting the Flap. Costing for the same also shall be included.It must be noted that this scheme is considered as a part of a combined pre-cooling system which will have an airtight plenum created between the wall panel and the area around the ACU as defined above. So while the insulated panel will be billed as per the the insulation panel rates, the cutting for the panel, the flashings, etc as needed for the pre-cooling unit arrangement should be considered while quoting the cost of panels.
455AIR COOLING UNITS - Air Cooling Units for Cold Storage 1-- VHT Ground Floor(General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Luve / Guentner / Thermofin /eqvt approvedType of Unit -Single / Twin: Single coil typeType of Refrigerant feed: HFC - DXCapacity - kW: 19Evap. Temp. & TD ‘C’: (-)4 °C / 4°CCoil / Fin MOC: Cu / AlFin spacing -mm: 6 mmFin type: PlateFinned coil length -m: To be MentionedTotal fan capacity of each unit– CMH: 22000External sp. Wg, mm: 6No of Fans/Unit: 2/3Fan Motor -kW each: To be MentionedAir throw -m: 10 mDrain pan insulation: RequiredDrain pan heating: Not requiredType of Defrosting: ElectricalFan peripheral heating: Not requiredSuitable Supporting structure from primary support at roof level or mounting stand (if supporting from floor level) to be considered in the costing as well.
456AIR COOLING UNITS - Air Cooling Units Cold Storage2,3 - VHT Ground Floor(General details as per REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Luve / Guentner / Thermofin /eqvt approvedType of Unit -Single / Twin: Single coil typeType of Refrigerant feed: HFC - DXCapacity - kW: 14Evap. Temp. & TD ‘C’: (-)4 °C / 4°CCoil / Fin MOC: Cu / AlFin spacing -mm: 6 mmFin type: PlateFinned coil length -m: To be MentionedTotal fan capacity of each unit– CMH: 16200External sp. Wg, mm: 3No of Fans/Unit: 2/3Fan Motor -kW each: To be MentionedAir throw -m:10mDrain pan insulation: RequiredDrain pan heating: Not requiredType of Defrosting: electricalFan peripheral heating: Not requiredSuitable Supporting structure from primary support at roof level or mounting stand (if supporting from floor level) to be considered in the costing as well.
457AIR COOLING UNITS - Air Cooling Units VHT Post Cooling Chamber- VHT Ground Floor(General details as per REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Luve / Guentner / Thermofin/eqvt approvedType of Unit -Single / Twin: Single coil typeType of Refrigerant feed: HFC - DXCapacity - kW: 20Evap. Temp. & TD ‘C’: 5 °C / 6°CCoil / Fin MOC: Cu / AlFin spacing -mm: 6 mmFin type: PlateFinned coil length -m: To be MentionedTotal fan capacity of each unit– CMH: 18500External sp. Wg, mm: 3No of Fans/Unit: 2/3Fan Motor -kW each: To be MentionedAir throw -m:5.5 mDrain pan insulation: RequiredDrain pan heating: Not requiredType of Defrosting: electricalFan peripheral heating: Not requiredSuitable Supporting structure from primary support at roof level or mounting stand (if supporting from floor level) to be considered in the costing as well.
458Refrigeration Piping, Fittings & Valves for Pre-cooling 1 & 2,Cold Storage 1, 2,3- VHT Ground Floor ref system (General details as per REFRIGERATION SYSTEM of GTS) The piping shall be of refrigeration quality The piping shall be of refrigeration quality seamless copper tubes and the valves shall be brassomatic / Henry or equivalent make. The piping shall be included accessories such as filter, drier, sight glass, heat exchanger, suction lineaccumulator etc. as per P & I diagram approved by Consultant. Adequate number of supports shall be included. The piping shall be supported at distances of maximum 1.5 m from each other with suitably placed GS threaded rods of minimum 6 mm thickness when outside the chamber and piping shall be run on cable trays of size suitable to fit the pipes including insulation. Common cable trays can be considered depending on the suitability at site, however the same shall be acceptable to the consultant / owner. Overall, the piping execution shall ensure proper workmanship and a neat and tidy work is expected with straight horizontal and vertical lines and proper supporting. Under no circumstances shall any additional charges be demanded by the contractor for ensuring the same.The suction and discharge lines shall be designed for a maximum pressure drop corresponding to 1.1 deg. C drop in saturated evaporating and condensing temperatures. The liquid line shall be designed for maximum pressure drop corresponding to a drop 0.5 to 1 deg. C in saturation temperature. The piping shall be designed with proper slope in the direction of Refrigerant flow and to ensure proper oil return to the compressor and should be installed with adequate supports to avoid undue vibration. The piping should be thoroughly cleaned as per standard practice prior to installation.Refrigeration piping,fittings,valves,interconnecting condensing & evaporator unit complete with standard controls & accessories, supports as may be required shall be included in cost.layout drawing showing proposed location of condesing units is atttached for your reference.upto 15 m piping (1m= 1m suction + 1m liquid) per unit considered in the item costing.
459Suction line insulation for Pre-cooling 1 & 2,Cold Storage 1, 2,3- VHT Ground Floor ref system(General details as per REFRIGERATION SYSTEM of GTS) Suction line insulation with EPDM/ Cross-Linked Polyethylene (Cross-Linked Polyethylene (XLPE))/Equivalent insulation with minimum 28G Aluminium foil Clading in the covered areas and Weatherproof Clading in areas exposed to sunlight and is uncovered ; e.g. Woven glass cloth with epoxy coating or Armacheck GC/equivalent Clading with suitable fittings and Adhesives.Alternatively,Fevicol Weather protect coat applied as per manufacturers recommendation may be used for entire insulation protection. Insulation supports shall be half round or full round heavy duty PVC pipe sections of relevant size which shall be atleast 150 mm in length and shall be placed below every support (if necessary). This is essentially ensuring that the insulation compression at the support is at the minimum. Thickness - 25mm
460Drain piping for Pre-cooling 1 & 2,Cold Storage 1, 2,3- VHT Ground Floor ref system with rigid U-PVC pipe from A.C. units to to suitable drain point complete with 'U' Traps for each cold room and supports.Drain lines (inside the chambers) to have 10 mm EPDM / Eqvt. insulation with factory backed Aluminium foil.Individiual Drain outlet line from ACU pipe size shall be same as the drain outlet of ACU and further the header shall be at least one size higher than the drain outlet connection size. Further, higher sizes may be considered as per the consultants/owner's recommendation
461Controls and Instruments ffor Pre-cooling 1 & 2,Cold Storage 1, 2,3- VHT Ground Floor ref system(a) Thermostatic expansion valves for each Air condensing units(b) Digital temperature indicator cum controllers (0 to 50 deg. C range) (c) Liquid line solenoid valves, DANFOSS / SPORLAN /EQVT make (d) Digital temperature cum RH indicator (minus 20 to 50 deg. C range), for A.C. units to be placed outside the each cold rooms for each chamber.
462First charge refrigeration gas and oil etc. as required upto commissioning and final handling over of plant.for Pre-cooling 1 & 2,Cold Storage 1, 2,3- VHT Ground Floor ref system
463Painting of equipment/piping / piping supports etc. as per standard colour codes with initial coat of red oxide primer and two coats of synthetic enamel paint for Pre-cooling 1 & 2,Cold Storage 1, 2,3- VHT Ground Floor ref system
464Electrical work for Refrigeration System for Pre-cooling 1 & 2,Cold Storage 1, 2,3- VHT Ground Floor ref systemElectrical control panel shall be manufactured as per specifications menioned in GTS and approved GA drawings.The Panel shall be comprising of following: a) Suitable Incomer of ACB / MCCB / MCB / RCBO of required rating and as per enclosed specification and approval. b) All Suitable rating MCB's, MPCB's, RCBO's, starters, relays, etc for various motors as used in the equipments shall be selected as per type 2 co ordination chart provided by the manufacturer. c) MCBs for control circuit d) Each starter shall be provided with facility for remote Start/Stop operation.This panel shall be located in the plant room (on terrace level) and shal have weather proof enclosure with suitable MCB's/RCCB's/RCBO's near the condensing unit. Job includes Electrical Power cabling (armoured) to all the outgoing feeders along with PVC medium duty Conduit/ pregalvanised Cable tray's, etc as per requirement and power cabling shall be as per specifications given in GTS.Control wiring with PVC insulated copper conductor with conduits as required for the refrigeration and other systems as defined here.Local Protection through MCB's/RCCB's/RCBO's for A.C. units, fan motors and other remotely located motors shall be part of the job.The Job shall also include earthing for control panel and various motors etc. using required sizes earthing conductors using GI/Cu earthing strips or Cu Conductors, all as per IS.The control panel shall have provision for interlocking of various equipment as per standard practice. Single electrical supply will be provided for the ref. panel further distribution shall be considered in refrigeration system
465Miscellaneous Items for Pre-cooling 1 & 2,Cold Storage 1, 2,3- VHT Ground Floor ref systema) Vibration isolators for condensing units, supporting rods / Frame for A.C. Units with insulation, steel structure for mouting condensing units etc. as may be required b) Minor structural openings in walls / panels etc for piping, cabling etc. and finishing.
466Charges for Installation, Testing and Commissioning for Pre-cooling 1 & 2,Cold Storage 1, 2,3- VHT Ground Floor ref systemInstallation, testing and commissioning of all above equipment / material as per the system requirement. All tools and tackles, welding machines, welding rods and gases etc. required for fabrication, erection, testing and commissioning shall be arranged by the contractor at his cost. The plant shall be erected, tested, commissioned as per Consultant's approved drawings / specifications and instructions to his and Employer's satisfaction. The refrigeration system shall be pressure tested and evacuated as per standard practice before charging the refrigerant. The water lines shall also be pressure tested as per standard practice. The plant shall be run for a period of three days after commoissioning by the contractor, to assess the plant performance The contractor shall provide 3 hard copies of operation & maintenance for the plant along with as built drawings. The contractor shall also arrange the training of the operating staff for proper operation & maintenance of the plant (included in above rates)
467Refrigeration System for VHT first Floor- left side
468AIR COOLED CONDENSING UNITS For Cold Storage 1- VHT first Floor- left side (General details as per REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make SEMI-HERMETIC compressor working on R134A / R407C, Air cooled condenser, Liquid receiver,Oil separator with check valve in discharge line, Base frame for mounting, H.P. / L.P.switches, Suction accumulator Vibration eliminator, Oil pr switch and pressure gauges , Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required.Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. It is also noted that the unit may work at higher temperature evaporation >7 deg C, condenser & refrigerant shall be selected accordingly.Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows :Capacity: 19 KWDesign Temperature: (-)4 deg. C evap. Maximum ambient Temperature: 40 deg C ambientMinimum fin spacing: 2 mm
469AIR COOLED CONDENSING UNITS for Cold Storage 2,3- VHT first Floor- left side (General details as per REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make SEMI-HERMETIC compressor working on R134A / R407C, Air cooled condenser, Liquid receiver,Oil separator with check valve in discharge line, Base frame for mounting, H.P. / L.P.switches, Suction accumulator Vibration eliminator, Oil pr switch and pressure gauges , Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required.Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature.It is also noted that the unit may work at higher temperature evaporation >7 deg C, condenser & refrigerant shall be selected accordingly.Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows :Capacity: 17 KWDesign Temperature: (-)4 deg. C evap. Maximum ambient Temperature: 40 deg C ambientMinimum fin spacing: 2 mm
470AIR COOLING UNITS - Air Cooling Units for Pre-cooling chamber 1,2- VHT first Floor- left side (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / Alfa Luve / Guentner /Thermofin/ Eqvt, Model: To be MentionedType of Unit -Single / Twin: Twin coil type,Type of Refrigerant feed: HFC - DXCapacity -52 kW: , Evap. Temp. & TD ‘C’: (-)4 °C / 4 °CCoil / Fin MOC: Cu / Al, Fin spacing -mm: 6 mmFin type: Plate, Finned coil length -m: To be MentionedTotal fan capacity of each unit– CMH: 53500, External sp. Wg, mm: 25No of Fans/Unit: 3/4, Fan Motor -kW each: To be MentionedAir throw -m: 8 m, Drain pan insulation: RequiredDrain pan heating: Not requiredType of Defrosting: ElectricalFan peripheral heating: Not requiredSuitable Supporting structure from primary support at roof level or mounting stand (if supporting from floor level) to be considered in the costing as well.Product Covering Flap - Suitable product covering flap made of PVC sheet / EQVT sturdy material to be mounted on the unit above the fan(s) to ensure proper air flow through the produce. There shall be suitable reinforcement inside the flap as well as at the ends for supporting the Flap. Costing for the same also shall be included.It must be noted that this scheme is considered as a part of a combined pre-cooling system which will have an airtight plenum created between the wall panel and the area around the ACU as defined above. So while the insulated panel will be billed as per the the insulation panel rates, the cutting for the panel, the flashings, etc as needed for the pre-cooling unit arrangement should be considered while quoting the cost of panels.
471AIR COOLING UNITS - Air Cooling Units for Cold Storage 1-- VHT first Floor- left side(General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Luve / Guentner / Thermofin /eqvt approvedType of Unit -Single / Twin: Single coil typeType of Refrigerant feed: HFC - DXCapacity - kW: 19Evap. Temp. & TD ‘C’: (-)4 °C / 4°CCoil / Fin MOC: Cu / AlFin spacing -mm: 6 mmFin type: PlateFinned coil length -m: To be MentionedTotal fan capacity of each unit– CMH: 22000External sp. Wg, mm: 6No of Fans/Unit: 2/3Fan Motor -kW each: To be MentionedAir throw -m: 10 mDrain pan insulation: RequiredDrain pan heating: Not requiredType of Defrosting: ElectricalFan peripheral heating: Not requiredSuitable Supporting structure from primary support at roof level or mounting stand (if supporting from floor level) to be considered in the costing as well.
472AIR COOLING UNITS - Air Cooling Units Cold Storage2,3 - VHT first Floor- left side(General details as per REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Luve / Guentner / Thermofin /eqvt approvedType of Unit -Single / Twin: Single coil typeType of Refrigerant feed: HFC - DXCapacity - kW: 17Evap. Temp. & TD ‘C’: (-)4 °C / 4°CCoil / Fin MOC: Cu / AlFin spacing -mm: 6 mmFin type: PlateFinned coil length -m: To be MentionedTotal fan capacity of each unit– CMH: 19500External sp. Wg, mm: 3No of Fans/Unit: 2/3Fan Motor -kW each: To be MentionedAir throw -m:10 mDrain pan insulation: RequiredDrain pan heating: Not requiredType of Defrosting: electricalFan peripheral heating: Not requiredSuitable Supporting structure from primary support at roof level or mounting stand (if supporting from floor level) to be considered in the costing as well.
473Refrigeration Piping, Fittings & Valves ffor Pre-cooling chamber 1,2 & Cold storage 1,2,3- VHT first Floor Left Side (General details as per REFRIGERATION SYSTEM of GTS) The piping shall be of refrigeration quality The piping shall be of refrigeration quality seamless copper tubes and the valves shall be brassomatic / Henry or equivalent make. The piping shall be included accessories such as filter, drier, sight glass, heat exchanger, suction lineaccumulator etc. as per P & I diagram approved by Consultant. Adequate number of supports shall be included. The piping shall be supported at distances of maximum 1.5 m from each other with suitably placed GS threaded rods of minimum 6 mm thickness when outside the chamber and piping shall be run on cable trays of size suitable to fit the pipes including insulation. Common cable trays can be considered depending on the suitability at site, however the same shall be acceptable to the consultant / owner. Overall, the piping execution shall ensure proper workmanship and a neat and tidy work is expected with straight horizontal and vertical lines and proper supporting. Under no circumstances shall any additional charges be demanded by the contractor for ensuring the same.The suction and discharge lines shall be designed for a maximum pressure drop corresponding to 1.1 deg. C drop in saturated evaporating and condensing temperatures. The liquid line shall be designed for maximum pressure drop corresponding to a drop 0.5 to 1 deg. C in saturation temperature. The piping shall be designed with proper slope in the direction of Refrigerant flow and to ensure proper oil return to the compressor and should be installed with adequate supports to avoid undue vibration. The piping should be thoroughly cleaned as per standard practice prior to installation.Refrigeration piping,fittings,valves,interconnecting condensing & evaporator unit complete with standard controls & accessories, supports as may be required shall be included in cost.layout drawing showing proposed location of condesing units is atttached for your reference.upto 15 m piping (1m= 1m suction + 1m liquid) per unit considered in the item costing.
474Suction line insulation for Pre-cooling chamber 1,2 & Cold storage 1,2,3- VHT first Floor Left Side(General details as per REFRIGERATION SYSTEM of GTS) Suction line insulation with EPDM/ Cross-Linked Polyethylene (Cross-Linked Polyethylene (XLPE))/Equivalent insulation with minimum 28G Aluminium foil Clading in the covered areas and Weatherproof Clading in areas exposed to sunlight and is uncovered ; e.g. Woven glass cloth with epoxy coating or Armacheck GC/equivalent Clading with suitable fittings and Adhesives.Alternatively,Fevicol Weather protect coat applied as per manufacturers recommendation may be used for entire insulation protection. Insulation supports shall be half round or full round heavy duty PVC pipe sections of relevant size which shall be atleast 150 mm in length and shall be placed below every support (if necessary). This is essentially ensuring that the insulation compression at the support is at the minimum. Thickness - 25mm
475Drain piping for Pre-cooling chamber 1,2 & Cold storage 1,2,3- VHT first Floor Left Side with rigid U-PVC pipe from A.C. units to to suitable drain point complete with 'U' Traps for each cold room and supports.Drain lines (inside the chambers) to have 10 mm EPDM / Eqvt. insulation with factory backed Aluminium foil.Individiual Drain outlet line from ACU pipe size shall be same as the drain outlet of ACU and further the header shall be at least one size higher than the drain outlet connection size. Further, higher sizes may be considered as per the consultants/owner's recommendation
476Controls and Instruments for Pre-cooling chamber 1,2 & Cold storage 1,2,3- VHT first Floor Left Side(a) Thermostatic expansion valves for each Air condensing units(b) Digital temperature indicator cum controllers (0 to 50 deg. C range) (c) Liquid line solenoid valves, DANFOSS / SPORLAN /EQVT make (d) Digital temperature cum RH indicator (minus 20 to 50 deg. C range), for A.C. units to be placed outside the each cold rooms for each chamber.
477First charge refrigeration gas and oil etc. as required upto commissioning and final handling over of plant.for Pre-cooling chamber 1,2 & Cold storage 1,2,3- VHT first Floor Left Side
478Painting of equipment/piping / piping supports etc. as per standard colour codes with initial coat of red oxide primer and two coats of synthetic enamel paint for Pre-cooling chamber 1,2 & Cold storage 1,2,3- VHT first Floor Left Side
479Electrical work for Refrigeration System for Pre-cooling chamber 1,2 & Cold storage 1,2,3- VHT first Floor Left SideElectrical control panel shall be manufactured as per specifications menioned in GTS and approved GA drawings.The Panel shall be comprising of following: a) Suitable Incomer of ACB / MCCB / MCB / RCBO of required rating and as per enclosed specification and approval. b) All Suitable rating MCB's, MPCB's, RCBO's, starters, relays, etc for various motors as used in the equipments shall be selected as per type 2 co ordination chart provided by the manufacturer. c) MCBs for control circuit d) Each starter shall be provided with facility for remote Start/Stop operation.This panel shall be located in the plant room (on terrace level) and shal have weather proof enclosure with suitable MCB's/RCCB's/RCBO's near the condensing unit. Job includes Electrical Power cabling (armoured) to all the outgoing feeders along with PVC medium duty Conduit/ pregalvanised Cable tray's, etc as per requirement and power cabling shall be as per specifications given in GTS.Control wiring with PVC insulated copper conductor with conduits as required for the refrigeration and other systems as defined here.Local Protection through MCB's/RCCB's/RCBO's for A.C. units, fan motors and other remotely located motors shall be part of the job.The Job shall also include earthing for control panel and various motors etc. using required sizes earthing conductors using GI/Cu earthing strips or Cu Conductors, all as per IS.The control panel shall have provision for interlocking of various equipment as per standard practice. Single electrical supply will be provided for the ref. panel further distribution shall be considered in refrigeration system
480Miscellaneous Items for Pre-cooling chamber 1,2 & Cold storage 1,2,3- VHT first Floor Left Sidea) Vibration isolators for condensing units, supporting rods / Frame for A.C. Units with insulation, steel structure for mouting condensing units etc. as may be required b) Minor structural openings in walls / panels etc for piping, cabling etc. and finishing.
481Charges for Installation, Testing and Commissioning for Pre-cooling chamber 1,2 & Cold storage 1,2,3- VHT first Floor Left SideInstallation, testing and commissioning of all above equipment / material as per the system requirement. All tools and tackles, welding machines, welding rods and gases etc. required for fabrication, erection, testing and commissioning shall be arranged by the contractor at his cost. The plant shall be erected, tested, commissioned as per Consultant's approved drawings / specifications and instructions to his and Employer's satisfaction. The refrigeration system shall be pressure tested and evacuated as per standard practice before charging the refrigerant. The water lines shall also be pressure tested as per standard practice. The plant shall be run for a period of three days after commoissioning by the contractor, to assess the plant performance. The contractor shall provide 3 hard copies of operation & maintenance for the plant along with as built drawings. The contractor shall also arrange the training of the operating staff for proper operation & maintenance of the plant (included in above rates)
482AIR COOLED CONDENSING UNITS For Pre-cooling 1 & 2- VHT first Floor- RIGHT side (General details as per REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make SEMI-HERMETIC compressor working on R134A / R407C, Air cooled condenser, Liquid receiver,Oil separator with check valve in discharge line, Base frame for mounting, H.P. / L.P.switches, Suction accumulator Vibration eliminator, Oil pr switch and pressure gauges , Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required.Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. It is also noted that the unit may work at higher temperature evaporation >7 deg C, condenser & refrigerant shall be selected accordingly.Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows :Capacity: 30 KWDesign Temperature: (-)4 deg. C evap. Maximum ambient Temperature: 40 deg C ambientMinimum fin spacing: 2 mm
483AIR COOLED CONDENSING UNITS For Cold Storage 1,2- VHT first Floor- RIGHT side (General details as per REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make SEMI-HERMETIC compressor working on R134A / R407C, Air cooled condenser, Liquid receiver,Oil separator with check valve in discharge line, Base frame for mounting, H.P. / L.P.switches, Suction accumulator Vibration eliminator, Oil pr switch and pressure gauges , Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required.Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. It is also noted that the unit may work at higher temperature evaporation >7 deg C, condenser & refrigerant shall be selected accordingly.Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows :Capacity: 13 KWDesign Temperature: (-)4 deg. C evap. Maximum ambient Temperature: 40 deg C ambientMinimum fin spacing: 2 mm
484AIR COOLING UNITS - Air Cooling Units for Pre-cooling chamber 1,2- VHT first Floor- RIGHT side (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / Alfa Luve / Guentner /Thermofin / Eqvt, Model: To be MentionedType of Unit -Single / Twin: Twin coil type,Type of Refrigerant feed: HFC - DXCapacity -60 kW: , Evap. Temp. & TD ‘C’: (-)4 °C / 4 °CCoil / Fin MOC: Cu / Al, Fin spacing -mm: 6 mmFin type: Plate, Finned coil length -m: To be MentionedTotal fan capacity of each unit– CMH: 62000, External sp. Wg, mm: 25No of Fans/Unit: 3/4, Fan Motor -kW each: To be MentionedAir throw -m: 8 m, Drain pan insulation: RequiredDrain pan heating: Not requiredType of Defrosting: ElectricalFan peripheral heating: Not requiredSuitable Supporting structure from primary support at roof level or mounting stand (if supporting from floor level) to be considered in the costing as well.Product Covering Flap - Suitable product covering flap made of PVC sheet / EQVT sturdy material to be mounted on the unit above the fan(s) to ensure proper air flow through the produce. There shall be suitable reinforcement inside the flap as well as at the ends for supporting the Flap. Costing for the same also shall be included.It must be noted that this scheme is considered as a part of a combined pre-cooling system which will have an airtight plenum created between the wall panel and the area around the ACU as defined above. So while the insulated panel will be billed as per the the insulation panel rates, the cutting for the panel, the flashings, etc as needed for the pre-cooling unit arrangement should be considered while quoting the cost of panels.
485AIR COOLING UNITS - Air Cooling Units for Cold Storage 1,2-- VHT first Floor- RIGHT side(General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Luve / Guentner / Thermofin/eqvt approvedType of Unit -Single / Twin: Single coil typeType of Refrigerant feed: HFC - DXCapacity - kW: 13Evap. Temp. & TD ‘C’: (-)4 °C / 4°CCoil / Fin MOC: Cu / AlFin spacing -mm: 6 mmFin type: PlateFinned coil length -m: To be MentionedTotal fan capacity of each unit– CMH: 15000External sp. Wg, mm: 6No of Fans/Unit: 2/3Fan Motor -kW each: To be MentionedAir throw -m: 10 mDrain pan insulation: RequiredDrain pan heating: Not requiredType of Defrosting: ElectricalFan peripheral heating: Not requiredSuitable Supporting structure from primary support at roof level or mounting stand (if supporting from floor level) to be considered in the costing as well.
486Refrigeration Piping, Fittings & Valves for Pre-cooling 1 & 2,Cold Storage 1, 2 VHT FIRST Floor Right side ref system (General details as per REFRIGERATION SYSTEM of GTS) The piping shall be of refrigeration quality The piping shall be of refrigeration quality seamless copper tubes and the valves shall be brassomatic / Henry or equivalent make. The piping shall be included accessories such as filter, drier, sight glass, heat exchanger, suction lineaccumulator etc. as per P & I diagram approved by Consultant. Adequate number of supports shall be included. The piping shall be supported at distances of maximum 1.5 m from each other with suitably placed GS threaded rods of minimum 6 mm thickness when outside the chamber and piping shall be run on cable trays of size suitable to fit the pipes including insulation. Common cable trays can be considered depending on the suitability at site, however the same shall be acceptable to the consultant / owner. Overall, the piping execution shall ensure proper workmanship and a neat and tidy work is expected with straight horizontal and vertical lines and proper supporting. Under no circumstances shall any additional charges be demanded by the contractor for ensuring the same.The suction and discharge lines shall be designed for a maximum pressure drop corresponding to 1.1 deg. C drop in saturated evaporating and condensing temperatures. The liquid line shall be designed for maximum pressure drop corresponding to a drop 0.5 to 1 deg. C in saturation temperature. The piping shall be designed with proper slope in the direction of Refrigerant flow and to ensure proper oil return to the compressor and should be installed with adequate supports to avoid undue vibration. The piping should be thoroughly cleaned as per standard practice prior to installation.Refrigeration piping,fittings,valves,interconnecting condensing & evaporator unit complete with standard controls & accessories, supports as may be required shall be included in cost.layout drawing showing proposed location of condesing units is atttached for your reference.upto 15 m piping (1m= 1m suction + 1m liquid) per unit considered in the item costing.
487Suction line insulation for Pre-cooling 1 & 2,Cold Storage 1, 2 VHT FIRST Floor Right side ref system(General details as per REFRIGERATION SYSTEM of GTS) Suction line insulation with EPDM/ Cross-Linked Polyethylene (XLPE)/Equivalent insulation with minimum 28G Aluminium foil Clading in the covered areas and Weatherproof Clading in areas exposed to sunlight and is uncovered ; e.g. Woven glass cloth with epoxy coating or Armacheck GC/equivalent Clading with suitable fittings and Adhesives.Alternatively,Fevicol Weather protect coat applied as per manufacturers recommendation may be used for entire insulation protection. Insulation supports shall be half round or full round heavy duty PVC pipe sections of relevant size which shall be atleast 150 mm in length and shall be placed below every support (if necessary). This is essentially ensuring that the insulation compression at the support is at the minimum. Thickness - 25mm
488Drain piping for Pre-cooling 1 & 2,Cold Storage 1, 2 VHT FIRST Floor Right side ref system with rigid U-PVC pipe from A.C. units to to suitable drain point complete with 'U' Traps for each cold room and supports.Drain lines (inside the chambers) to have 10 mm EPDM / Eqvt. insulation with factory backed Aluminium foil.Individiual Drain outlet line from ACU pipe size shall be same as the drain outlet of ACU and further the header shall be at least one size higher than the drain outlet connection size. Further, higher sizes may be considered as per the consultants/owner's recommendation
489Controls and Instruments for Pre-cooling 1 & 2,Cold Storage 1, 2 VHT FIRST Floor Right side ref system(a) Thermostatic expansion valves for each Air condensing units(b) Digital temperature indicator cum controllers (0 to 50 deg. C range) (c) Liquid line solenoid valves, DANFOSS / SPORLAN /EQVT make (d) Digital temperature cum RH indicator (minus 20 to 50 deg. C range), for Air Conditioner units to be placed outside the each cold rooms for each chamber.
490First charge refrigeration gas and oil etc. as required upto commissioning and final handling over of plant for Pre-cooling 1 & 2,Cold Storage 1, 2 VHT FIRST Floor Right side ref system
491Painting of equipment/piping / piping supports etc. as per standard colour codes with initial coat of red oxide primer and two coats of synthetic enamel paint for Pre-cooling 1 & 2,Cold Storage 1, 2 VHT FIRST Floor Right side ref system
492Electrical work for Refrigeration System for Pre-cooling 1 & 2,Cold Storage 1, 2 VHT FIRST Floor Right side ref systemElectrical control panel shall be manufactured as per specifications menioned in GTS and approved GA drawings.The Panel shall be comprising of following: a) Suitable Incomer of ACB / MCCB / MCB / RCBO of required rating and as per enclosed specification and approval. b) All Suitable rating MCB's, MPCB's, RCBO's, starters, relays, etc for various motors as used in the equipments shall be selected as per type 2 co ordination chart provided by the manufacturer. c) MCBs for control circuit d) Each starter shall be provided with facility for remote Start/Stop operation.This panel shall be located in the plant room (on terrace level) and shal have weather proof enclosure with suitable MCB's/RCCB's/RCBO's near the condensing unit. Job includes Electrical Power cabling (armoured) to all the outgoing feeders along with PVC medium duty Conduit/ pregalvanised Cable tray's, etc as per requirement and power cabling shall be as per specifications given in GTS.Control wiring with PVC insulated copper conductor with conduits as required for the refrigeration and other systems as defined here.Local Protection through MCB's/RCCB's/RCBO's for Air Conditioner units, fan motors and other remotely located motors shall be part of the job.The Job shall also include earthing for control panel and various motors etc. using required sizes earthing conductors using GI/Cu earthing strips or Cu Conductors, all as per IS.The control panel shall have provision for interlocking of various equipment as per standard practice. Single electrical supply will be provided for the ref. panel further distribution shall be considered in refrigeration system
493Miscellaneous Itemsfor Pre-cooling 1 & 2,Cold Storage 1, 2 VHT FIRST Floor Right side ref systema) Vibration isolators for condensing units, supporting rods / Frame for Air condensing Units with insulation, steel structure for mouting condensing units etc. as may be required b) Minor structural openings in walls / panels etc for piping, cabling etc. and finishing.
494Charges for Installation, Testing and Commissioning for Pre-cooling 1 & 2,Cold Storage 1, 2 VHT FIRST Floor Right side ref systemInstallation, testing and commissioning of all above equipment / material as per the system requirement. All tools and tackles, welding machines, welding rods and gases etc. required for fabrication, erection, testing and commissioning shall be arranged by the contractor at his cost. The plant shall be erected, tested, commissioned as per Consultant's approved drawings / specifications and instructions to his and Employer's satisfaction. The refrigeration system shall be pressure tested and evacuated as per standard practice before charging the refrigerant. The water lines shall also be pressure tested as per standard practice. The plant shall be run for a period of three days after commoissioning by the contractor, to assess the plant performance. The contractor shall provide 3 hard copies of operation & maintenance for the plant along with as built drawings. The contractor shall also arrange the training of the operating staff for proper operation & maintenance of the plant (included in above rates)
495Charges for Installation, Testing and Commissioning for Pre-cooling 1 & 2,Cold Storage 1, 2 VHT FIRST Floor Right side ref systemInstallation, testing and commissioning of all above equipment / material as per the system requirement. All tools and tackles, welding machines, welding rods and gases etc. required for fabrication, erection, testing and commissioning shall be arranged by the contractor at his cost. The plant shall be erected, tested, commissioned as per Consultant's approved drawings / specifications and instructions to his and Employer's satisfaction. The refrigeration system shall be pressure tested and evacuated as per standard practice before charging the refrigerant. The water lines shall also be pressure tested as per standard practice. The plant shall be run for a period of three days after commoissioning by the contractor, to assess the plant perfoOne Running Meterance. The contractor shall provide 3 hard copies of operation & maintenance for the plant along with as built drawings. The contractor shall also arrange the training of the operating staff for proper operation & maintenance of the plant (included in above rates)
496HVAC System for VHT PACKHOUSE & HWT STACKING AREA:
497HVAC SYSTEM FOR VHT PACKHOUSE & HWT STACKING AREA: Supplying, erecting, testing and commissioning VRF / VRV air conditioning system, outdoor unit (ODU) complying type-IV OEM standards working on refrigerant R410A/R32 or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and nonstop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner completeCooling Capacity 246kW [70 TR]
498Supply, installation, testing and commissioning of VRV / VRF based ductable type, high static indoor unit (IDU) having nominal cooling capacity as specified having EER as per BEE standards and specifications with low noise evaporator fans with dc/ec motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain Tonne of Refrigerationay, expansion device, cordlessremote con Tonne of Refrigerationol with necessary con Tonne of Refrigerationols and elec Tonne of Refrigerationical terminal to receive power supply, etc. having anti-corrosive coating suitable for coastal area, with suitable ceiling suspension arrangement, with an elec Tonne of Refrigerationonic con Tonne of Refrigerationol console and any additional refrigerant and oil charge as per requirement during installation connected with the system complete.Suitable support arrangement from the ceiling level shall be considered in the costing.7 One Number in VHT packhouse & 2 One Number in HWT stacking areaCooling Capacity 28.13kW [8.0 Tonne of Refrigeration]
499Cordless Remote with receiver kit for ducted units.
500CRC (Centralized Controller)
501Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of of liberally sized dia. for liquid line, suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permereance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.(mode of measurement- 1 One Running meter = 1 One Running meter suction + 1 One Running meter liquid pipe)
502Supplying and installation of high pressure grade required size copper connection Y or T- Joints / refnet for liquid and suction line complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV / VRF air conditioning system.
503Supply, Installation, Testing and commissioning of Drain Piping using heavy duty PVC pipe with 9 mm EPDM / Nitrile foam insulation. The drain shall be led to the nearest toilet or drain point as specified by the owner. Dia 32 mm
504Supply, Installation, Testing and commissioning of Drain Piping using heavy duty PVC pipe with 9 mm EPDM / Nitrile foam insulation. The drain shall be led to the nearest toilet or drain point as specified by the owner. Dia 50 mm
505Ducting: Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round / elliptical ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8 mm (22G) thick
506Ducting: Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round / elliptical ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8 mm (24G) thick
507Supply, fabrication, installation an testing of flexible canvass connections constructed between ductable unit / dampers / ducting of required size with flexible double canvas sleeve complete.
508Providing and fixing 13 mm thick acoustic insulation using ArmaSound or approvedequivalent on HVAC ducts / equipment, including adhesive fixing, joint sealing,complete as per manufacturer’s recommendations and site requirements.
509Providing and fixing 13 mm thick closed-cell nitrile rubber insulation on HVACducts / pipes using approved adhesive, with vapour-tight sealing of all joints,complete as per manufacturer’s recommendations.
510Supply and erection of Supply and Return air Grilles & Diffusers in Aluminium construction and with powder coated finish as per the following details to the satisfaction of the owners and architects :
511Supply air diffusers with dampers in various sizes
512Linear Supply air grilles with black matt finish dampers in various sizes
513Return air diffusers (without dampers)
514Return air grilles (without dampers)
515Power cabling with copper conductor (min. 3 core x 1.5 Square milimeter / 3 core x 2.5 Square milimeter OR as required) with end termination for Indoor units with Plug Top, Earthing connection etc. (from indoor to interconnecting power)
516Supply & installation charges for communication cable between IDUs &ODU
517Double Earthing with GI wire as required min. 8 SWG for Outdoor Units and Indoor Units as required.
518Testing, Commissioning and additional charge of Gas and compressor Oil as may be required upto handing over of the plant
519Supply, Installation, Testing and commissioning of motorized dampers for SA & RA , preferebly UL555 certified, with necessary actuators and suitable for vertical positioning for supply air and return air openings into the AHU room / enclosure
520Supply, Installation, Testing and commissioning of Branch dampers with volume control for ensuring correct air balancing.
521Providing and fixing weather proof panel with MCCB / MCB for incomer from the main electrical panel and outgoing isolation switches (RCCB) of required rating for individual ODU modules. Power cables from this panel to the individual ODU modules 10m each along with earthing etc shall be considered in this item
522Supply, Installation, Testing and commissioning of cabinet /inline type fresh air blower 2500 cmh preferably centrifulal type to ensure low noise levels with washable filter having efficiency 90% down to 20 micron, and 30 mm wg static pressure. The rate should include Supply, Installation, Testing and commissioning of the starter panel and cabling to the starter panel and starter panel to Fresh air blower.
523Supply, Installation, Testing and commissioning of hard PVC pipe for fresh air connection to indoor unit including elbow, bends, coupler , Butterfly valve for controlling airflow at 9 One Number outlet etc There shall be insulation on the piping as required to ensure that there will be no condensation on the pipes under any circumstances. Piping shall include elbows, removable and cleanable type air filter and supports from wall / ceiling. The piping shall be insulated with 6mm thick EPDM / Nitrile foam insulation with factory backed Aluminium foil.Bird screen with insect traps to be included. Dia 100 mm
524HVAC SYSTEM FOR HWT PACKHOUSE AREA: Supplying, erecting, testing and commissioning VRF / VRV air conditioning system, outdoor unit (ODU) complying type-IV OEM standards working on refrigerant R410A/R32 or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and nonstop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner completeCooling Capacity: 316kW [90 TR]
525Supply, installation, testing and commissioning of VRV / VRF based ductable type, high static indoor unit (IDU) having nominal cooling capacity as specified having EER as per BEE standards and specifications with low noise evaporator fans with dc/ec motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordlessremote control with necessary controls and electrical terminal to receive power supply, etc. having anti-corrosive coating suitable for coastal area, with suitable ceiling suspension arrangement, with an electronic control console and any additional refrigerant and oil charge as per requirement during installation connected with the system complete.The ductable indoor unit shall be designed, selected, installed and commissioned to ensure low-noise operation.Suitable support arrangement from the ceiling level shall be considered in the costing.Cooling Capacity 28.13kW [8.0 TR]
526Cordless Remote with receiver kit for ducted units. FOR HWT PACKHOUSE AREA
527CRC (Centralized Controller) FOR HWT PACKHOUSE AREA
528Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of of liberally sized dia. for liquid line, suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water peOne Running Metereance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.(mode of measurement- 1 One Running meter = 1 One Running meter suction + 1 One Running meter liquid pipe)FOR HWT PACKHOUSE AREA
529Supplying and installation of high pressure grade required size copper connection Y or T- Joints / refnet for liquid and suction line complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the noOne Running Meteral operation of the VRV / VRF air conditioning system.FOR HWT PACKHOUSE AREA
530Supply, Installation, Testing and commissioning of Drain Piping using heavy duty PVC pipe with 9 mm EPDM / Nitrile foam insulation. The drain shall be led to the nearest toilet or drain point as specified by the owner. Dia 32 mmFOR HWT PACKHOUSE AREA
531Supply, Installation, Testing and commissioning of Drain Piping using heavy duty PVC pipe with 9 mm EPDM / Nitrile foam insulation. The drain shall be led to the nearest toilet or drain point as specified by the owner. Dia 50 mmFOR HWT PACKHOUSE AREA
532Ducting: Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round / elliptical ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8 mm (22G) thickFOR HWT PACKHOUSE AREA
533Ducting: Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round / elliptical ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8 mm (24G) thickFOR HWT PACKHOUSE AREA
534Supply, fabrication, installation an testing of flexible canvass connections constructed between ductable unit / dampers / ducting of required size with flexible double canvas sleeve complete.FOR HWT PACKHOUSE AREA
535Providing and fixing 13 mm thick acoustic insulation using ArmaSound or approvedequivalent on HVAC ducts / equipment, including adhesive fixing, joint sealing,complete as per manufacturer’s recommendations and site requirements.FOR HWT PACKHOUSE AREA
536Providing and fixing 13 mm thick closed-cell nitrile rubber insulation on HVACducts / pipes using approved adhesive, with vapour-tight sealing of all joints,complete as per manufacturer’s recommendations.FOR HWT PACKHOUSE AREA
537Supply and erection of Supply and Return air Grilles & Diffusers in Aluminium construction and with powder coated finish as per the following details to the satisfaction of the owners and architects :FOR HWT PACKHOUSE AREA
538Supply air diffusers with dampers in various sizesFOR HWT PACKHOUSE AREA
539Linear Supply air grilles with black matt finish dampers in various sizesFOR HWT PACKHOUSE AREA
540Return air diffusers (without dampers) FOR HWT PACKHOUSE AREA
541Return air grilles (without dampers) FOR HWT PACKHOUSE AREA
542Power cabling with copper conductor (min. 3 core x 1.5 Square milimeter / 3 core x 2.5 Square milimeter OR as required) with end termination for Indoor units with Plug Top, Earthing connection etc. (from indoor to interconnecting power) FOR HWT PACKHOUSE AREA
543Supply & installation charges for communication cable between IDUs &ODU FOR HWT PACKHOUSE AREA
544Double Earthing with GI wire as required min. 8 SWG for Outdoor Units and Indoor Units as required. FOR HWT PACKHOUSE AREA
545Testing, Commissioning and additional charge of Gas and compressor Oil as may be required upto handing over of the plantFOR HWT PACKHOUSE AREA
546Providing and fixing weather proof panel with MCCB / MCB for incomer from the main electrical panel and outgoing isolation switches (RCCB) of required rating for individual ODU modules. Power cables from this panel to the individual ODU modules 10m each along with earthing etc shall be considered in this itemFOR HWT PACKHOUSE AREA
547Supply, Installation, Testing and commissioning of cabinet /inline type fresh air blower 3500 cmh preferably centrifulal type to ensure low noise levels with washable filter having efficiency 90% down to 20 micron, and 20 mm wg static pressure. The rate should include Supply, Installation, Testing and commissioning of the starter panel and cabling to the starter panel and starter panel to Fresh air blower. FOR HWT PACKHOUSE AREA
548Supply, Installation, Testing and commissioning of hard PVC pipe for fresh air connection to indoor unit including elbow, bends, coupler , Butterfly valve for controlling airflow at 9 One Number outlet etc There shall be insulation on the piping as required to ensure that there will be no condensation on the pipes under any circumstances. Piping shall include elbows, removable and cleanable type air filter and supports from wall / ceiling. The piping shall be insulated with 6mm thick EPDM / Nitrile foam insulation with factory backed Aluminium foil.Bird screen with insect traps to be included. Dia 100 mmFOR HWT PACKHOUSE AREA
549HVAC SYSTEM FOR OFFICE AREA: Supplying, erecting, testing and commissioning VRF / VRV air conditioning system, outdoor unit (ODU) complying type-IV OEM standards working on refrigerant R410A/R32 or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and nonstop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner complete54 HP x 1 One NumberCooling Capacity 151kW [43.2 TR]
550HVAC SYSTEM FOR IRRADIATION UNTREATED AREA & TREATED AREA: Supplying, erecting, testing and commissioning VRF / VRV air conditioning system, outdoor unit (ODU) complying type-IV OEM standards working on refrigerant R410A/R32 or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and nonstop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner complete 60 HP X 3 One Number. & 30 HP X 1 One Number Cooling Capacity 590kW [168 TR]
551Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominalcooling capacity 0.8 TR having EER as per BEE standards and specifications,suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
552Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominalcooling capacity 1.0TR having EER as per BEE standards and specifications,suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
553Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominalcooling capacity 1.6TR having EER as per BEE standards and specifications,suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
554Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominalcooling capacity 2 TR having EER as per BEE standards and specifications,suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
555Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominalcooling capacity 2.6 TR having EER as per BEE standards and specifications,suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
556Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominalcooling capacity 3.2 TR having EER as per BEE standards and specifications,suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
557Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominalcooling capacity 4 TR having EER as per BEE standards and specifications,suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
558Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominalcooling capacity 4.6 TR having EER as per BEE standards and specifications,suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
559Supply, Installation, Testing and commissioning of indoor units hi-wall typeSupply, Installation, Testing and commissioning of Hi-wall type split indoor AC units.Wireless Remote Controllers for Hi-wall Units with battery and ON/OFF functions along with temperature setting, etc. to be included.2.8 kW (0.8 TR), Hi-wall indoor unit
560Supply, Installation, Testing and commissioning of indoor units hi-wall typeSupply, Installation, Testing and commissioning of Hi-wall type split indoor AC units.Wireless Remote Controllers for Hi-wall Units with battery and ON/OFF functions along with temperature setting, etc. to be included.3.5 kW (1 TR), Hi-wall indoor unit
561Supply, Installation, Testing and commissioning of indoor units hi-wall typeSupply, Installation, Testing and commissioning of Hi-wall type split indoor AC units.Wireless Remote Controllers for Hi-wall Units with battery and ON/OFF functions along with temperature setting, etc. to be included.5.2 kW (1.5 TR), Hi-wall indoor unit
562Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of of liberally sized dia. for liquid line, suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.(mode of measurement- 1 One Running meter = 1 One Running meter suction + 1 One Running meter liquid pipe)
563Supplying and installation of high pressure grade required size copper connection Y or T- Joints / refnet for liquid and suction line complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV / VRF air conditioning system.
564Supply, Installation, Testing and commissioning of Drain Piping using heavy duty PVC pipe with 9 milimeter EPDM / Nitrile foam insulation. The drain shall be led to the nearest toilet or drain point as specified by the owner. Dia 32 milimeter
565Supply, Installation, Testing and commissioning of Drain Piping using heavy duty PVC pipe with 9 milimeter EPDM / Nitrile foam insulation. The drain shall be led to the nearest toilet or drain point as specified by the owner. Dia 50 milimeter
566Power cabling with copper conductor (min. 3 core x 1.5 Square milimeter / 3 core x 2.5 Square milimeter OR as required) with end termination for Indoor units with Plug Top, Earthing connection etc. (from indoor to interconnecting power)
567Supply & installation charges for Commissioning cable between IDUs &ODU
568Providing and fixing weather proof panel with MCCB / MCB for incomer from the main electrical panel and outgoing isolation switches (RCCB) of required rating for individual ODU modules. Power cables from this panel to the individual ODU modules upto 10m each along with earthing etc shall be considered in this item
569Double Earthing with GI wire as required min. 8 SWG for Outdoor Units and Indoor Units as required.
570Supply & Installation of floor mounted M S Stands for VRF outdoor Unit.
571Supply of Wireless Remote
572CRC (Centralized Controller)
573Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 milimeter thick) GI sheet of 150 milimeter width & 100 milimeter height comprising all required standard accessories.
574Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 milimeter thick) GI sheet of 200 milimeter width & 100 milimeter height comprising all required standard accessories.
575Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 milimeter thick) GI sheet of 300 milimeter width & 100 milimeter height comprising all required standard accessories.
576Testing, Comilimeterissioning and additional charge of Gas and compressor Oil as may be required upto handing over of the plant for VRF system for Office area, irradiation treated & untreated area HVAC system
577Supply, Installation, Testing and commissioning of cabinet /inline type fresh air blower 3000 cmh preferably centrifulal type to ensure low noise levels with washable filter having efficiency 90% down to 20 micron, and 35 milimeter wg static pressure. The rate should include Supply, Installation, Testing and commissioning of the starter panel and cabling to the starter panel and starter panel to Fresh air blower. for office area system
578Supply, Installation, Testing and commissioning of cabinet /inline type fresh air blower 10000 cmh preferably centrifulal type to ensure low noise levels with washable filter having efficiency 90% down to 20 micron, and 50 milimeter wg static pressure. The rate should include Supply, Installation, Testing and commissioning of the starter panel and cabling to the starter panel and starter panel to Fresh air blower. for untreated & treated area VRF system
579Supply, Installation, Testing and commissioning of Automatic air Flow Controllers / regulating valves (Aldes or equivalent) for supply of controlled air flow with an alteration for existing flexible pvc pipe duct and necessary joints, sealing, couplings complete at position. as per individual fresh air requirement of the indoor units.
580Ducting: Supply, installation, balancing and comilimeterissioning of fabricated at site GSS sheet metal rectangularducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. FOR FRESH AIR SUPPLYSite/factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8 milimeter (24G) thick
581Supply, Installation, Testing and commissioning of hard PVC pipe for fresh air connection to indoor unit including elbow, bends, coupler etc There shall be insulation on the piping as required to ensure that there will be no condensation on the pipes under any circumstances. Piping shall include elbows, removable and cleanable type air filter and supports from wall / ceiling. The piping shall be insulated with 6milimeter thick EPDM / Nitrile foam insulation with factory backed Aluminium foil.Bird screen with insect traps to be included. Dia 300 milimeter
582Supply, Installation, Testing and commissioning of hard PVC pipe for fresh air connection to indoor unit including elbow, bends, coupler etc There shall be insulation on the piping as required to ensure that there will be no condensation on the pipes under any circumstances. Piping shall include elbows, removable and cleanable type air filter and supports from wall / ceiling. The piping shall be insulated with 6milimeter thick EPDM / Nitrile foam insulation with factory backed Aluminium foil.Bird screen with insect traps to be included. Dia 200 milimeter
583Supply, Installation, Testing and commissioning of hard PVC pipe for fresh air connection to indoor unit including elbow, bends, coupler etc There shall be insulation on the piping as required to ensure that there will be no condensation on the pipes under any circumstances. Piping shall include elbows, removable and cleanable type air filter and supports from wall / ceiling. The piping shall be insulated with 6milimeter thick EPDM / Nitrile foam insulation with factory backed Aluminium foil.Bird screen with insect traps to be included. Dia 100 milimeter
584Supply, Installation, Testing and commissioning of pre-insulated Inter connecting Flexible circular Ducting of 100 milimeter dia / suitable dia with clamps & suitable for leak proof connection of fresh air PVC Piping to the individual cassette units
585Supplying, installing, testing and commissioning split type variable speed inverter technology room Airconditioning unit 1 TR capacity having minimum BEE 3 star rating suitable to operate on single phase A.C. supply having 1 One Number of air handling unit hi-wall type complete with refrigerant R410A/R32 and copper condenser at position.Necessary refrigerant piping, duly insulated with Nitrile / EPDM insulation power/control wiring between indoor & outdoor unit, mounting stand, and drain piping to be led to the nearest drain point shall be included in the costing.
586Supplying, installing, testing and commissioning split type variable speed inverter technology room Airconditioning unit 1.5 TR capacity having minimum BEE 3 star rating suitable to operate on single phase A.C. supply having 1 One Number of air handling unit hi-wall type complete with refrigerant R410A/R32 and copper condenser at position.Necessary refrigerant piping, duly insulated with Nitrile / EPDM insulation power/control wiring between indoor & outdoor unit, mounting stand, and drain piping to be led to the nearest drain point shall be included in the costing.
587Supplying, installing, testing and commissioning split type variable speed inverter technology room Airconditioning unit 2 TR capacity having minimum BEE 3 star rating suitable to operate on single phase A.C. supply having 1 One Number of air handling unit hi-wall type complete with refrigerant R410A/R32 and copper condenser at position.Necessary refrigerant piping, duly insulated with Nitrile / EPDM insulation power/control wiring between indoor & outdoor unit, mounting stand, and drain piping to be led to the nearest drain point shall be included in the costing.
588VENTILATION SYSTEM - Exhaust Fans - approx 230 milimeter dia complete with(a) Fan with direct coupled motor(b) Mounting ring and brackets(c) Gravity louvers (d) Bird screenNecessary electrical cabling etc shall be included in the cost.
589VENTILATION SYSTEM - Exhaust Fans - approx 300 milimeter dia complete with(a) Fan with direct coupled motor(b) Mounting ring and brackets(c) Gravity louvers (d) Bird screenCap. : 4500 cmh Necessary electrical cabling etc shall be included in the cost.
590VENTILATION SYSTEM - Exhaust Fans - approx 450 milimeter dia complete with(a) Fan with direct coupled motor(b) Mounting ring and brackets(c) Gravity louvers (d) Bird screenNecessary electrical cabling etc shall be included in the cost.
591Toilet / Changing Room ventilation:Supply, Installation, Testing and commissioning of cabinet /inline type exhaust air blower preferably centrifulal type to ensure low noise levels. The rate should include Supply, Installation, Testing and commissioning of the starter panel and cabling to the starter panel and starter panel to exhaust air blower. The fan shall be suitable for static pressure of 12 milimeter.Mounting bracket. stand as may be required shall be incuded in the costing. cost for electrical supply from avaible nearest point shall also be included.2500 cmh (1470 cfm) :
592Workers Toilet ventilation:Supply, erection and testing of air ducting made out of GS sheet of Grade 120 as per latest IS 277 (120 gsm) or higher complete with neoprene gaskets, branch dampers, guide vanes and supports as per standard practice. All ducting joints shall be flange type joints only for exhaust ducting regardless of the size of the duct.
59322 Gauge (0.8 milimeter)
59424 Gauge (0.63 milimeter)
595Workers Toilet ventilation:Supply and erection of Exhaust air Grilles in Aluminium construction and with powder coated finish of various sizes to the satisfaction of the owners and architects :
596Supply, Installation, Testing and commissioning of Centrifugal type fan with cabinet suitable for location on exposed terrace with forward / backward curved blades and DIDW construction. The capacity shall be as mentioned below. The fan shall be suitable for static pressure of 12 milimeter.. Fan shall have washable filter having efficiency 90% down to 20 micron.Cost of starter control panel and power wiring from the point of supply to fan along with earthing etc shall considered complete as per site requirement.For HWT treatment room supply fan: 33750 cmh (19850 cfm) :
597Supply, Installation, Testing and commissioning of Centrifugal type fan with cabinet suitable for location on exposed terrace with forward / backward curved blades and DIDW construction. The capacity shall be as mentioned below. The fan shall be suitable for static pressure of 5 milimeter.. Cost of starter control panel and power wiring from the point of supply to fan along with earthing etc shall considered complete as per site requirement.For HWT treatment room supply fan: 33750 cmh (19850 cfm) :
598Supply, Installation, Testing and commissioning of Centrifugal type fan with cabinet suitable for location on exposed terrace with forward / backward curved blades and DIDW construction. The capacity shall be as mentioned below. The fan shall be suitable for static pressure of 12 milimeter.Cost of starter control panel, cotroller with air sensor to on & off the fan based on the ambient temp. and power , control wiring from the point of supply to fan along with earthing etc shall considered complete as per site requirement.For irradtiation cell top exhaust fan: 25000 cmh (14700 cfm) :
599Supply, Installation, Testing and commissioning of Centrifugal type fan with cabinet suitable for location on exposed terrace with forward / backward curved blades and DIDW construction. The capacity shall be as mentioned below. The fan shall be suitable for static pressure of 12 milimeter. Cost of starter control panel, cotroller with air sensor to on & off the fan based on the ambient temp. and power , control wiring from the point of supply to fan along with earthing etc shall considered complete as per site requirement.For VHT ATTIC exhaust fan:7000 cmh (4117 cfm) :
600Electrical work for Ventilation System - for HWT treatment room exhaust fan & supply fan Ventilation system Electrical control panel shall be manufactured as per specifications menioned in GTS and approved GA drawings.The Panel shall be comprising of following: a) Suitable Incomer of MCCB / MCB / RCBO of required rating and as per enclosed specification and approval. b) All Suitable rating MCB's, MPCB's, RCBO's, starters, relays, etc for various motors as used in the equipment shall be selected as per type 2 co ordination chart provided by the manufacturer. c) MCBs for control circuit d) Each starter shall be provided with facility for remote Start/Stop operation.This panel shall be located on terrace and there shall be weather proof enclosure with suitable MCB's/RCCB's/RCBO's near the Fan unit. Job includes Electrical Power cabling (armoured) to all the outgoing feeders along with PVC medium duty Conduit/ pregalvanised Cable tray's, etc as per requirement and power cabling shall be as per specifications given in GTS.Control wiring with PVC insulated copper conductor with conduits as required for the systems as defined here.Local Protection through MCB's/RCCB's/RCBO's for A.C. units, fan motors and other remotely located motors shall be part of the job.The Job shall also include earthing for control panel and various motors etc. using required sizes earthing conductors using GI/Cu earthing strips or Cu Conductors, all as per IS.The control panel shall have provision for interlocking of various equipment as per standard practice.
601Electrical work for Ventilation System - for irradtiation cell top Ventilation system Electrical control panel shall be manufactured as per specifications menioned in GTS and approved GA drawings.The Panel shall be comprising of following: a) Suitable Incomer of MCCB / MCB / RCBO of required rating and as per enclosed specification and approval. b) All Suitable rating MCB's, MPCB's, RCBO's, starters, relays, etc for various motors as used in the equipment shall be selected as per type 2 co ordination chart provided by the manufacturer. c) MCBs for control circuit d) Each starter shall be provided with facility for remote Start/Stop operation.This panel shall be located on terrace and there shall be weather proof enclosure with suitable MCB's/RCCB's/RCBO's near the Fan unit. Job includes Electrical Power cabling (armoured) to all the outgoing feeders along with PVC medium duty Conduit/ pregalvanised Cable tray's, etc as per requirement and power cabling shall be as per specifications given in GTS.Control wiring with PVC insulated copper conductor with conduits as required for the systems as defined here.Local Protection through MCB's/RCCB's/RCBO's for A.C. units, fan motors and other remotely located motors shall be part of the job.The Job shall also include earthing for control panel and various motors etc. using required sizes earthing conductors using GI/Cu earthing strips or Cu Conductors, all as per IS.The control panel shall have provision for interlocking of various equipment as per standard practice.
602Electrical work for Ventilation System - for VHT ATTIC Ventilation system Electrical control panel shall be manufactured as per specifications menioned in GTS and approved GA drawings.The Panel shall be comprising of following: a) Suitable Incomer of MCCB / MCB / RCBO of required rating and as per enclosed specification and approval. b) All Suitable rating MCB's, MPCB's, RCBO's, starters, relays, etc for various motors as used in the equipment shall be selected as per type 2 co ordination chart provided by the manufacturer. c) MCBs for control circuit d) Each starter shall be provided with facility for remote Start/Stop operation.This panel shall be located on terrace and there shall be weather proof enclosure with suitable MCB's/RCCB's/RCBO's near the Fan unit. Job includes Electrical Power cabling (armoured) to all the outgoing feeders along with PVC medium duty Conduit/ pregalvanised Cable tray's, etc as per requirement and power cabling shall be as per specifications given in GTS.Control wiring with PVC insulated copper conductor with conduits as required for the systems as defined here.Local Protection through MCB's/RCCB's/RCBO's for A.C. units, fan motors and other remotely located motors shall be part of the job.The Job shall also include earthing for control panel and various motors etc. using required sizes earthing conductors using GI/Cu earthing strips or Cu Conductors, all as per IS.The control panel shall have provision for interlocking of various equipment as per standard practice.
603Supply, erection and testing of air ducting made out of GS sheet of Grade 120 as per latest IS 277 (120 gsm) or higher complete with neoprene gaskets, branch dampers, guide vanes and supports as per standard practice. All ducting joints shall be flange type joints only for exhaust ducting regardless of the size of the duct.10 milimeter EPDM/nitrile insulation shall be applied where duct goes through AC area or in return area path of AC upto 1 m beyond the specific zone22 Gauge (0.8 milimeter)
604Supply, erection and testing of air ducting made out of GS sheet of Grade 120 as per latest IS 277 (120 gsm) or higher complete with neoprene gaskets, branch dampers, guide vanes and supports as per standard practice. All ducting joints shall be flange type joints only for exhaust ducting regardless of the size of the duct. 10 milimeter EPDM/nitrile insulation shall be applied where duct goes through AC area or in return area path of AC upto 1 m beyond the specific zone24 Gauge (0.63 milimeter)
605Supply and erection of Exhaust air Grilles in Aluminium construction and with powder coated finish of various sizes to the satisfaction of the owners and architects
606Supply and erection of Supply air Grilles with dampers in Aluminium construction and with powder coated finish of various sizes to the satisfaction of the owners and architects
607Vapour heat Treatment Machine
608Design, manufacture, supply, installation, testing, commissioning, validation and training of Vapour Heat Treatment (VHT) System of 3000 One Kilogram mango per batch capacity, Sanshu make (Japan) model EHK-300PC, suitable for phytosanitary treatment of mangoes for export from India to Japan, Korea and other regulated importing countries, complete in all respects.The VHT system shall be of differential pressure type, fully automatic, electric heater based , designed to operate with saturated vapour heat to unifoOne Running Meterly raise fruit pulp temperature to 46–48°C within 4 hours and hold as per approved treatment schedules, fully compliant with NSPM-20 and acceptable to Indian Plant Quarantine (NPPO), MAFF (Japan) and APQA (Korea) , NZ & other importing countriesThe system shall include SS 304 inner chamber, pre-coated steel outer panels, high static differential pressure air circulation fans, electric heaters, automatic proportional control of temperature and humidity, PLC/microprocessor-based control panel with touch screen HMI, hybrid type temperature & humidity recorder (minimum 250 mm recording width) with SD/PC card data storage, peOne Running Meteranent PT100 pulp temperature sensors (minimum 6 One Number.) with spare sensors, provision for portable sensors for PQ validation, airtight insulated doors with sensor access ports and inspection door, complete safety interlocks and protections.The scope shall further include food-grade polypropylene trays and pallets (252 containers per batch, 6 pallets per batch, with 3 complete sets), loading carriages, standard spare parts, complete electrical cabling, earthing, interlocks, potable water connections, cooling arrangements, and all accessories required for safe and continuous operation. Please Enable Macros to View BoQ information
609Design, manufacture, supply, installation, testing, commissioning, validation and training of Vapour Heat Treatment (VHT) System of 3000 One Kilogram mango per batch capacity, Sanshu make (Japan) model EHK-300PC, suitable for phytosanitary treatment of mangoes for export from India to Japan, Korea and other regulated importing countries, complete in all respects.The VHT system shall be of differential pressure type, fully automatic, electric heater based , designed to operate with saturated vapour heat to unifoOne Running Meterly raise fruit pulp temperature to 46–48°C within 4 hours and hold as per approved treatment schedules, fully compliant with NSPM-20 and acceptable to Indian Plant Quarantine (NPPO), MAFF (Japan) and APQA (Korea) , NZ & other importing countriesThe system shall include SS 304 inner chamber, pre-coated steel outer panels, high static differential pressure air circulation fans, electric heaters, automatic proportional control of temperature and humidity, PLC/microprocessor-based control panel with touch screen HMI, hybrid type temperature & humidity recorder (minimum 250 mm recording width) with SD/PC card data storage, peOne Running Meteranent PT100 pulp temperature sensors (minimum 6 One Number.) with spare sensors, provision for portable sensors for PQ validation, airtight insulated doors with sensor access ports and inspection door, complete safety interlocks and protections.The scope shall further include food-grade polypropylene trays and pallets (252 containers per batch, 6 pallets per batch, with 3 complete sets), loading carriages, standard spare parts, complete electrical cabling, earthing, interlocks, potable water connections, cooling arrangements, and all accessories required for safe and continuous operation. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56291974
AUTHORITY Government Departments
TENDER VALUE 127.61 Crore
LAST DATE 07-08-2026
Authority
Authority Name Department Of Agriculture
Work Description Tender for Construction Of Multi-Commodity Packhouse (Part A-Civil Work), Including Supply & Installation Of Vapour Heat Treatment (Vht) Unit With Integrated Packhouse And Irradiation Unit & Scientific Cold Storage Facilities (Part B - Plant & Machinery) At Bapgaon (Thane)
Basic Detail
Tender No SMART/MSAMB/EI/BAPGAON/93/2024
Bidding Type Tender
Location
City Thane
State Maharashtra
Key Dates
Publish Date 03 Jul 2026
Submission Date 07 Aug 2026
Open Date 10 Aug 2026
Finance
Tender Value 127.61 Crore
Tender Fee 17700
EMD Ref. Documents
Exemption Not Available
Document List
6c209757-87e5-4ad3-99d4-8e8ca205896d.html
AllDrawingsbapgaon.pdf
BOQ_2252830.xls
RFBBAPGAONSMART.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 34 days
Aug 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 37 days

Tender Documents

Download All (ZIP) ↓
html

6c209757-87e5-4ad3-99d4-8e8ca205896d.html

pdf

AllDrawingsbapgaon.pdf

xls

BOQ_2252830.xls

pdf

RFBBAPGAONSMART.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender