Tender For Construction Of Samajmandir At Magasvargiy Vasti Loni Tal-Khandala Dist.Satara
Tender Value
12.66 Lakhs
Estimated cost
Bid Submission
17 Jul 2026
13 days left
EMD
12667
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Satara → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Samajmandir At Magasvargiy Vasti Loni Tal-Khandala Dist.Satara
BOQ
| Sl. No. | Item Description |
| 1 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. - (Lift upto 1.5 metre) By Mechanical MeansItem / Page No : 2 / 153Specification No : Bd.A.1Spec. Page No : 259 |
| 2 | Excavation for foundation in hard murum including removing the excavated material upto a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. (Lift upto 1.5 metre) By Mechanical MeansItem / Page No : 6 / 153Specification No : Bd.A.2Spec. Page No : 259 |
| 3 | Providing dry trap/ granite/ quartzite/ gneiss rubble stone soiling 15 centimetre to 20 centimetre thick including hand packing and compacting, excetra complete.Item / Page No : 38 / 157Specification No : Bd.A.12Spec. Page No : 264 |
| 4 | Providing and laying Cast in situ/Ready Mix, cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailling out water, formwork, laying/ pumping, compacting and curing, excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed, excetra) (using ARTIFICIAL SAND).Item / Page No : 1 / 175Specification No : Bd.E.1Spec. Page No : 287-288Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 5 | Providing and laying in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of reinforced cement concrete columns and steel stanchions, excetra including bailling out water, formwork, cover blocks, compaction, curing and roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel), excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND).Item / Page No : 11 / 178Specification No : Bd.F.3, B-7Spec. Page No : 298, 38-40Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 6 | Providing and laying cast in situ / Ready Mix cement conrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed, including steel centering, formwork, cover blocks,aying/pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.with fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 31 / 179Specification No : Bd.F.5, B-7Spec. Page No : 300, 38-40Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 7 | Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 50 / 181Specification No : Bd.F.6, B-7Spec. Page No : 300-301, 38-40Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 8 | Providing second class burnt brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 in foundations and plinth of inner walls / in plinth of external walls including bailling out water manually, striking joints, on unexposed faces, racking out joints on exposed faces and watering, excetra complete. (using ARTIFICIAL SAND).Item / Page No : 1 / 197Specification No : Bd.G.1Spec. Page No : 313Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 9 | Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 5 / 197Specification No : Bd.G.5Spec. Page No : 315Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 10 | Filling in plinth and floors with approved excavated materials in 15 centimetre to 20 centimetre layers including watering and compacting, excetra complete.Item / Page No : 36 / 157Specification No : Bd.A.10Spec. Page No : 262-263 |
| 11 | Filling in plinth and floors with contractors material / brought from outside and approved by Engineer In-Charge, in 15 centimetre to 20 centimetre layers including watering and compaction, excetra complete.Item / Page No : 37 / 157Specification No : Bd.A.11Spec. Page No : 263-264 |
| 12 | Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks,laying / pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 70 / 182Specification No : Bd.F.8, B-7Spec. Page No : 302-303, 38-40Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 13 | Providing internal cement plaster 12 milimetre thick in a single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 4 / 209Specification No : Bd.L.2Spec. Page No : 368Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 14 | Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For Ground Floor)Item / Page No : 33 / 188Specification No : Bd.F.17Spec. Page No : 306 |
| 15 | Providing internal cement plaster 20 milimetre thick in single coat in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 6 / 209Specification No : Bd.L.4Spec. Page No : 368Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 16 | Providing and laying vitrified matt finish tiles of having size 590 milimetre to 605 milimetre X to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 42 / 217Specification No : Bd.M.12Spec. Page No : 385Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 17 | Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on a bed of 1:4 cement mortar including float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 35 / 216Specification No : Bd.M.22 BSpec. Page No : 390Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 18 | Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding Indian Standard of approved manufacturer and of approved colour to the plastered surfaces including cleaning, preparing the plaster surfaces, applying primer coat, scaffolding, if necessary and watering the surface for two days, excetra complete. (For Ground Floor)Item / Page No : 25 / 225Additional Specifications : The work shall be carried out as per instructions of Engineer in charge. |
| 19 | Providing and fixing mild steel grill work for windows, ventilators, excetra 15 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, excetra complete. (For Ground Floor)Item / Page No : 2 / 264Specification No : Bd.U.1Spec. Page No : 537 |
| 20 | Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20 metre X 0.90 metre size made out 18 gauge (1.25 milimetre) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols excetra with approved colour shade paint complete, on M.S.angle of size 35 milimetre X 35 milimetre X 3 milimetre frame with properly cross braced mild steel angles of size 35 milimetre X 35 milimetre X 3 milimetre duly painted including two mild steel angle iron posts of size 65 milimetre X 65 milimetre X 6 milimetre, 3.65 metre long painted with alternate black and white bands of 25 centimetre width including all fixtures excetraand fixing the boards in 1:4:8 concrete block of size 60 centimetre X 60 centimetre X 75 centimetre including, excavation, refilling, transportation, and labour etc complete. Spec. number As directed by Engineer in ChargeItem / Page No : 36 / 60Specification No : MoRTH-801Spec. Page No : ---Additional Specifications : The work shall be carried out as per instructions of Engineer in charge. |
| 21 | Royalty charges for various building construction bonafied materials which are used for government bonafied works and for which Royalty charges are to be paid by the contractor. (This Item is to be paid to the contractor only after he pays the Royalty amount to Revenue department and produces the required voucher.)Item / Page No : 3 / 0Additional Specifications : 1. Government of Maharashtra, Revenue and Forest Department Gazette Number 146 Dated 04/06/2021 and Government of Maharashtra Public Works Department State Schedule of Rates 2021-22 General Note Number A(v), Page 5. 2. The amount of royalty charges will be paid only after submission of the receipt in original from Revenue authority for payment of royalty to Government, stating the name of work. 3. Above / below percentage quoted by the contractor will not be applicable for this item. |
| 22 | Laboratory testing charges for various materials required for items of work, on the basis of testing frequency and charges fixed by Vigilence and Quality Control Circle, Pune.Item / Page No : 4 / 0Additional Specifications : 1. The amount of laboratory testing charges will be paid to contractor only after submission of the original receipt from the Vigillence and Quality Control Office with the name of work mensioned on it. 2. Above / below percentage quoted by the contractor will not be applicable for this item.Fineness Modulus (Sieve Analysis), Silt and Clay Content Test for Artificial Sand1 Test per Source |
| 23 | Compressive Strength of Cement Concrete Cube1 Test for quantity upto 5 cubic metre, 2 Tests for quantity above 5 cubic metre and upto 15 cubic metre, 3 Tests for quantity above 15 cubic metre and upto 30 cubic metre, 4 Tests for quantity above 30 cubic metre and upto 50 cubic metre. For quantity 50 cubic metre and above - 4 Tests + 1 Test for each additional 50 cubic metre |
| 24 | Sieve Analysis Test for Metal below 40 milimetre1 Test per 200.00 Cubic Metre |
| 25 | Tensile Strength, Percent Elongation, Yield Stress, Weight per Metre, Bend / Rebend Test, Proof Stress (Steel Bar upto 16 milimetre)1 Test per 5.00 Metric Ton |
| 26 | Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of three tracks with rectangular pipe having overall dimentsions 95 milimetre X 38 milimetre X 0.90 milimetre at weight 0.637 kilogram per running metre and window frame bottom track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 1.070 kilogram per running metre. Top and side track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jali with all required screws and nuts excetra complete. - With powder coating without box. (For Ground Floor)Item / Page No : 44 / 254Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 27 | Providing and fixing frame with / without ventilator of size as specified with non teak wood for doors and windows including chamfering, rounding, rebating holdfast of size 300 milimetre X 40 milimetre X 5 milimetre with oil painting, excetra complete. (For Ground Floor)Item / Page No : 2 / 245Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 28 | Providing and fixing solid core flush door shutter in double leaf 32 milimetre thick decorative type of exterior grade as per detailed drawings approved face veneers 3 milimetre thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides and finishing with French Polish, excetra complete (For Ground Floor)Item / Page No : 95 / 263Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge. |
| 29 | Waterproofing Treatment to new terrace by using Polymeric Cementitious Membrane as approved by Engineer in charge, followed by 112 milimetre thick brick bat coba covered with 20 milimetre mortar finish. If there are cracks on the bare slab, open the crack in V Groove and fill it with ready to use repair polymer modified mortar based on special cements, aldehyde based polymers with thixotropy modifying agents. If there are lots of honeycombs and identified bad patches of concrete the same should be grouted as per the instructions of site incharge. (The grouting shall be paid separately). Clean the entire surface thoroughly and over this prepared surface, apply three coats of polymeric Cementitious waterproofing coating having a non- toxic, 2-(methoxycarbonyl)-1-propene-Butyl-2 propenoate (MPBP) based polymeric waterproofing solution as approved by Engineer in-charge. Provide and lay 112 milimetre average thicknes of brick bat coba in cement mortar 1:5 over 12mm thick centimetre 1:3 bedding with one pouch of 330 grams of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents as approved by Engineer in charge per 50Kilogrambag of cement and finishing with 20 milimetre thick cement plaster in cement mortar 1:3 by mixing one 330 grams pouch of above admixture per 50Kilogrambag of cement, including all lead, liftsand laid to proper slope to drain off water entirely preparing bell mouth including watta,Item / Page No : 12 / 423Additional Specifications : The work shall be done as per instructions of Engineer in charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysJul 20, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender