Defence Statutory Bodies & Commissions/Committees Closing in 35 days TDR #56291905

Tender For Special Repair To Bldg No P-36/2&3(Cook House And Dining Hall) At Raiwala Mil Stn.

Issued by Statutory Bodies & Commissions/Committees · Dehradun, Uttarakhand
Tender Value
58.24 Lakhs
Estimated cost
Bid Submission
10 Aug 2026
35 days left
EMD
1.12 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dehradun → Uttarakhand
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair To Bldg No P-36/2&3(Cook House And Dining Hall) At Raiwala Mil Stn.

BOQ

Name of Work:- SPECIAL REPAIR TO BLDG NO P-36/2&3(COOK HOUSE AND DINING HALL) AT RAIWALA MIL STN.
Sl. No. Item Description
1Demolition of existing roof treatment i.e APP membrane incl cement screed, brick tiling incl mud mortar or lime concrete and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with Removal of existing roof treatment i.e APP membrane, brick tiling incl mud mortar and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance , scales, oil or any other loose material complete all as specified and directed.
2M&L PCC 1:2:4 type B-0 (using 12.5 mm graded stone agg) mixed with liquid water proofing compound (mixed as per manufacturer direction ) and finishing the surface even and smooth without using extra cement as in roof padding including making the V-groove on top surface 10 mm deep and filling solidly with a hot mixture of bitumen and clean dry sand in the ratio of 1:1 by weight complete all as specified and directed. Note :- 1. Liquid water proofing compound will be measured and paid seperately.2.The work is required to be carried out at non-accessible roof for double storey . The contractor shall make arrangement of scaffolding,safety & security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these item.
3M&L for one coat of cement slurry admixed with acrylic bonding compound SBR Latex liquid polymer (slurry will be prepared as per manufacturer direction) as to be used for bonding of new concrete/ mortar to old surface. Note :- (i)The work is required to be carried out at non-accessible roof for double storey . (ii)The contractor shall make arrangement of scaffolding,safety & security of workers and arrangement for approach to roof .(iii) The rates quoted shall deemed to be included for these item.
4M&L for water proofing treatment to non-accessible roof slab with APP based modified polymeric membrane as per manufacturer’s instructions with following course of description below :-(a) Applying evenly a tack coat of industrial bitumen 85/25 @ 1.20 Kg /Sqm, including cleaning the surface .(b) Providing APP based 5 layer polymeric membrane minimum weighing 3.6Kg/ Sqm and minimum 3mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by forced applications as per the manufacturer's instructions with side over lap of 75 mm and end overlap of 100 mm. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch ) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer(c) Apply two coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membranceNote :- 1. Liquid water proofing compound will be measured and paid seperately.2.The work is required to be carried out at non-accessible roof for double storey . The contractor shall make arrangement of scaffolding,safety & security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these item.
5M&L for PCC (1:1.5:3) type A-0, using 12.5mm graded stone aggregates, as in concrete angle-fillets with a radiaus of 75 to 100mm shall be provided at junctions between roofs, floor and vertical faces of walls (parapet, pillar for water tank staging and sunken floor) around obstacles such as pipes, chimney stacks etc. and other similar situation to ease up about corners mixed with integral water proofing compound as per manufactur direction )Note :- Integral water proofing compound (WPC) will be measured and paid seperately.
6Supply only WPC integral water proofing compound (Liquid type) complete all as specified and directed.
7Taking down chowkhats or frames with shutters ( without taking off shutters from the frames) of any description of following size complete all as specified and directed:-
8Area not exc 1.5 sqm each
9Area exc 1.5 sqm but not exc 4 sqm each
10M&L for MS fastner of FI 50x5mm size and length 200 to 250mm for fixing wooden door/ window frame and like in postion complete all as specified and directed.
11S&F factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ ceosetory windows and other frames/ chowkhat of following size comprising of virgin PVC polymer having K-value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) and 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and direction. Note: (i) For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable and variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.(ii) M.S. hold fast/ lugs or SS dash fasteners shall be measured and paid for separately.
1265mm x100mm size
1365mm x 125mm size
14M&L 30 mm thick Factory made solid WPC (Wood plastic composit) moulded gauged door shutter with wire mesh in any number of division with brown wood grain texture, including S.S wire mesh shall be fixed with 15x15 square tube in side rails with screwing 8x28 heat metal zink coated screws can be remove or fix again after changing of wire mesh when needed. The density of the shall be as per manufacture instruction complete all as specified and directed.
15M&L factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as specified and directed. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)complete all as specified and directed. Please Enable Macros to View BoQ information
16M&L factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as specified and directed. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56291905
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 58.24 Lakhs
LAST DATE 10-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair To Bldg No P-36/2&3(Cook House And Dining Hall) At Raiwala Mil Stn.
Basic Detail
Tender No 86481/RWL/E8
Bidding Type Tender
Location
City Dehradun
State Uttarakhand
Key Dates
Publish Date 03 Jul 2026
Submission Date 10 Aug 2026
Open Date 18 Aug 2026
Finance
Tender Value 58.24 Lakhs
Tender Fee 1000
EMD 1.12 Lakhs
Exemption Available
Document List
57192aaa-f779-41ac-a960-d8ad214b5208.html
BOQ_869352.xls
Tender86481.pdf
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 35 days
Aug 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 43 days

Tender Documents

Download All (ZIP) ↓
html

57192aaa-f779-41ac-a960-d8ad214b5208.html

xls

BOQ_869352.xls

pdf

Tender86481.pdf

pdf

Tendernotice_1 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders