Housing Urban and Rular Development Government Departments Closing in 12 days TDR #56291722

Tender For Under The District Court Gorakhpur, In The First Phase, The Work Of Installation Of Ac In The Court Rooms And Chambers Of The Honorable District Judge And Additional District Judge, District Court Headquarters And Outer Court Bansgaon.

Issued by Government Departments · Gorakhpur, Uttar Pradesh
Tender Value
1.98 Crore
Estimated cost
Bid Submission
16 Jul 2026
12 days left
EMD
11.90 Lakhs
Bank guarantee accepted
Document Fee
2354
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gorakhpur → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Under The District Court Gorakhpur, In The First Phase, The Work Of Installation Of Ac In The Court Rooms And Chambers Of The Honorable District Judge And Additional District Judge, District Court Headquarters And Outer Court Bansgaon.

BOQ

Name of Work:- जनपद न्यायालय गोरखपुर के अंतर्गत प्रथम चरण में माननीय जनपद न्यायाधीश एव अपर जनपद न्यायाधीश के न्यायालय कक्षों एवं चैम्बर ¼जनपद न्यायालय मुख्यालय एवं वाह्य न्यायालय बांसगॉव½ में ए०सी०स्थापना का कार्य ।
Sl. No. Item Description
1Supplying , Installation, Testing and Commissioning of 2.0 TR with 5 Star BEE Rating Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 52 degree Celcius (out door ambient temperature). Make:- Carrier/ Panasonic/ Bluestar/ LG . MR
2Supplying , Installation, Testing and Commissioning of 1.5 TR with 5 Star BEE Rating Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 52 degree Celcius (out door ambient temperature). Make:- Carrier/ Panasonic/ Bluestar/ LG. MR
35 KVA Voltage Stablizer for Air Conditioner Upto 2TR (130 - 300 Range) Copper Winding. MR
44 KVA Voltage Stablizer for Air Conditioner Upto 1.5TR (130 - 300 Range) Copper Winding.MR
5Supply of Out Door Unit stand for split type A.C MR
6SITC of suction/Discharge Copper pipe line in split A.C unit 1.8/2.0 ton capacity including brazing,nitrile rubber insulation 9mm thick class o etc comlete 3/8\\" (9.50mm) and 5/8\\" (15.90),MR
7SITC of suction/Discharge Copper pipe line in split A.C unit 1.5 ton capacity including brazing,nitrile rubber insulation 9mm thick class o etc comlete 1/4\\" (6.40mm) and 1/2\\" (12.70). MR
8S/I of heavy duty CPVC 20mm/25mm OD pipe for condensed water drain with clipping accessories complete. MR
9S/I of heavy duty CPVC 32 mm OD pipe for condensed water drain with clipping accessories complete. MR
10S & F of Door Closer. MR
112.5sqmm 3 core Round cable for A.c Connecting indoor to unit to Stablizer/power point. MR
122.5sqmm 4 core Round cable for A.c Connecting indoor/Outdoor. MR
13Design manufacturing, Supply Installation testing and commissioning of 630A LT Panel. The Panel shall be fabricated out of 2.0/1.6mm thick CRCA sheet steel, painted with Powder coated paint of shade as per the direction of Engineer In-Charge after proper sheet treatment process of sheet steel. The Bus bar of Panel shall be of High grade Electrical grade High Conductive Aluminum alloy of appropriate cross section as per rating. The calculation of continuous rating of Bus Bar shall be submitted. The Bus Bar shall be supported by non hygroscopic SMC/DMC Bus Bar supports which shall be mounted on proper interval to ensure bear the jerks of short Circuit as fault level require. The Fault level of Panel shall be 35kA for 1sec. All Indicating Lights shall be LED type and all wiring shall be done from PVC Insulated copper flexible wire. The Panel shall be completed in all respect and shall consist of following material.Incomer: 630Amp MCCB FP, 50kA – 1 SetOutgoing : 100A FP MCCB – 5 Set, and 63A FP MCCB – 2 Set. SOR 20.1.4 a (ii)
14Same as item No.1 But For Incomer: 200Amp MCCB FP – 1 Set, Outgoing : 63A FP MCCB – 3 Set. SOR 20.1.2 b (ii)
15Same as item No.1 But For Incomer: 100Amp ACB FP – 1 Set, Outgoing : 63A FP MCCB –1 Set and 32A FP MCCB – 2 Set. SOR 20.1.1 c (ii)
16Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Complete in all respect.including Lugs & Gland. 400 sq. mm 3-1/2 core . SOR 20.1/ 20.1.20
17Same As Above For 120 sq. mm 3-1/2 core. SOR 20.1/ 20.1.15
18Same As Above For 70 sq. mm 3-1/2 core. SOR 20.1/20.1.13
19Same As Above For 25 sq. mm 3-1/2 core. SOR 20.1/20.1.10
20S/F of 630 amp 4 pole Manual Change Over Switch .complete in all respect. RA
21S/F of 200 amp 4 pole Manual Change Over Switch .complete in all respect. RA
22S/F of 100 amp 4 pole Manual Change Over Switch .complete in all respect. RA
23Supplying and fixing of following ways surface/ recess mounting, Horizental type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bubar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . 4 way (4 + 12), Double door . D.S.R 2.4.1
24Supplying and fixing 5 amps to 32 amps TPN MCB rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. DSR 2.10.5
25Supplying and fixing 5 amps to 32 amps DPMCB rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. DSR 2.10.3
26Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4X 10sq.mm+2X6sq. mm earth wire D.S.R 1.14.10
27Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2X 6sq.mm+1X6sq. mm earth wire . D.S.R 1.14.4
28S/F suitable size GI box with modular plate and cover in front on surface or in recess , including providing and fixing 25 A modular socket outlet without SPMCB including connections, painting etc. as required. (807-285) DSR 1.57-DSR 2.10.1
29Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required..(2 for each Panel) DSR 5.2
30Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. DSR 5.15
31Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. DSR 5.18 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56291722
AUTHORITY Government Departments
TENDER VALUE 1.98 Crore
LAST DATE 16-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for Under The District Court Gorakhpur, In The First Phase, The Work Of Installation Of Ac In The Court Rooms And Chambers Of The Honorable District Judge And Additional District Judge, District Court Headquarters And Outer Court Bansgaon.
Basic Detail
Tender No 947/Nivida Suchna GKP-Zone-E/M Circle/2026-27 Dt 22.06.2026
Bidding Type Tender
Location
City Gorakhpur
State Uttar Pradesh
Key Dates
Publish Date 03 Jul 2026
Submission Date 16 Jul 2026
Open Date 16 Jul 2026
Finance
Tender Value 1.98 Crore
Tender Fee 2354
EMD 11.90 Lakhs
Exemption Not Available
Document List
20ad08ba-0465-4ad0-88da-3111239ed091.html
BOQ_2187367.xls
Tendernotice_1.pdf
Tendernotice_2 (3).pdf
Tendernotice_3 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Jul 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
html

20ad08ba-0465-4ad0-88da-3111239ed091.html

xls

BOQ_2187367.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2 (3).pdf

pdf

Tendernotice_3 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders