Drinking Water Supply and Sanitation Government Departments Closing in 11 days TDR #56290544

Tender For Repair Maintenance Work Of Mechanical Units And Electrical Repair & Maintenance Of Radial Gate Control Panels, Rest House, Power House And Illumination Arrangement At Crest Of Barna Dam And Saddle Dam Bari For The Year 2026-27 (Second Call

Issued by Government Departments · Hoshangabad, Madhya Pradesh
Tender Value
15.86 Lakhs
Estimated cost
Bid Submission
17 Jul 2026
11 days left
EMD
31732
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Hoshangabad → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair Maintenance Work Of Mechanical Units And Electrical Repair & Maintenance Of Radial Gate Control Panels, Rest House, Power House And Illumination Arrangement At Crest Of Barna Dam And Saddle Dam Bari For The Year 2026-27 (Second Call)

BOQ

Name of Work:- Repair maintenance work of mechanical units and electrical repair & maintenance of radial gate control panels, rest house, power house and illumination arrangement at crest of barna dam and saddle dam Bari for the Year 2026-27 (Second Call)
Sl. No. Item Description
1Providing and filling/ replacing gear oil of approved quality up to the required gauge level for Reduction gear unit of hoists/ gantry cranes including cost of all materials, machinery, labour etc. complete. 7 Ltr. Per gate X 12 no. = 84 Ltr.
2Providing and applying grease of approved quality to gate and hoist components requiring greasing as part of annual maintenance using grease gun wherever necessary including cost of all materials, machinery, labour, scaffolding etc. complete. 1.Trunion assembly = 2 nos. X 2 Kg = 4 kg Grease nipples, gear assembly rope drum of hoists assembly = 06 Kg X 2 nos. = 12 Kg 16 kg X 8 = 128 kg. 2. Roller assembly, Hoist assembly including pedestals motor shaft, gear assembly, drum etc. 10 Kg X 4 nos. = 40 Kg
3Providing and applying cardium compound of approved quality to wire ropes of hoists/ gantry cranes as part of annual maintenance including cost of all materials, machinery, labour etc. complete. 1. Length of wire rope 94 mtr. Area = πDL = 3.14 x 36/100x94=10.62 sq.m, compound required per sq. mtr. 2.47 kg x 10.62 sq.m = 26.25 kg x 08 no. = 210 kg, 2. Length of wire rope of emergency gate 110 mtr. , area = πDL = 3.14 x 26/1000 x 110 = 8.98 sq.m total area= 8.98, compound required per sq. mtr 2.47 kg x 8.98 = 22.18 kg 04 no. of sluice gate 22.18 x 4 = 88.72, 210+88.72=298.72, Say 300
4Providing and supplying of De-greasing / de-rusting phosphate coating Chemical (for Barna Dam gates and saddle dam gates) 4 ltr each gate 12x4=36 ltr
5Pre cleaning of gate components & Hoisting parts, removing of honeycombs, removing sand and dust particles from gear system, removing & cleaning of old grease & cleaning of gate arm, beam, trunion and other parts from animal remains etc., degreasing of de-rusting of gate motor, gate parts and hoisting including material required and labour complete job for 8 no. of radial gate, 3 no. of service gate and 1 no. of emergency gate Total 12 no. of gates. For radial gates {6 labour(0 X 496 for skilled, 2 X 438 for semiskilled & 2 X 405 for unskilled)} Total Rs. 2678
6Pre cleaning of gate components & Hoisting parts, removing of honeycombs, removing sand and dust particles from gear system, removing & cleaning of old grease & cleaning of gate arm, beam, trunion and other parts from animal remains etc., degreasing of de-rusting of gate motor, gate parts and hoisting including material required and labour complete job for 8 no. of radial gate, 3 no. of service gate and 1 no. of emergency gate Total 12 no. of gates. For sluice gates {4 labour(0 X496 for skilled, 1 X 438 for semi-skilled, 2 X 405 for unskilled)} Total Rs. 1744
7Post cleaning of gate components & Hoisting parts, control panel room, removing of cardium compound stains. Oil stains, old grease stains from gate and hoisting including material required and labour complete job for 8 no. of radial gate, 3 no. of service gate and 1 no. of emergency gate Total 12 no. of gates. For radial gates {4 labour(0 X 496 for skilled, 1 X 438 for semiskilled & 2 X 405 for unskilled)} Total Rs. 1744
8Post cleaning of gate components & Hoisting parts, control panel room, removing of cardium compound stains. Oil stains, old grease stains from gate and hoisting including material required and labour complete job for 8 no. of radial gate, 3 no. of service gate and 1 no. of emergency gate Total 12 no. of gates. For sluice gates {3 labour(1 X496 for skilled, 1 X 438 for semi-skilled, 1 X 405 for unskilled)} Total Rs. 1339
9Providing laying and jointing of following galvanized Iron (MS) Pipes with specials (such as bends, elbows, tees etc) class light, medium & heavy including testing of joints, cost of pipes, specials and jointing materials all complete. Pipes and sockets conforming to IS-1239/2011 Part II. Medium. 50mm dia.
10Providing laying and jointing of following galvanized Iron (MS) Pipes with specials (such as bends, elbows, tees etc) class light, medium & heavy including testing of joints, cost of pipes, specials and jointing materials all complete. Pipes and sockets conforming to IS-1239/2011 Part II. Medium. 100mm dia.
11Providing laying and jointing of following galvanized Iron (MS) Pipes with specials (such as bends, elbows, tees etc) class light, medium & heavy including testing of joints, cost of pipes, specials and jointing materials all complete. Pipes and sockets conforming to IS-1239/2011 Part II. Medium. 150mm dia.
12Providing and fixing G. I. Bend 90 in G.I. Pipe line including cutting threading testing etc. complete (Old work) conforming to IS 1879.50mm dia.
13Providing and fixing G. I. Bend 90 in G.I. Pipe line including cutting threading testing etc. complete (Old work) conforming to IS 1879. 100mm dia.
14Providing and fixing G. I. Bend 90 in G.I. Pipe line including cutting threading testing etc. complete (Old work) conforming to IS 1879. 150mm dia.
15Providing and fixing G. I. Nipple of minimum length in G.I. Pipe line including cutting, threading, testing and carriage etc. complete (Old work) conforming to IS 1879. 50mm dia.
16Providing and fixing G. I. Nipple of minimum length in G.I. Pipe line including cutting, threading, testing and carriage etc. complete (Old work) conforming to IS 1879. 100mm dia.
17Providing and fixing following check (non-return) valves Class-I, conforming to IS-778/1984 (Reaffirmed 2005) female ends, tested to 21.00 Kg/cm2. 50mm dia screwed
18Providing and fixing following check (non-return) valves Class-I, conforming to IS-778/1984 (Reaffirmed 2005) female ends, tested to 21.00 Kg/cm2. 65mm dia flanged
19Providing and fixing following check (non-return) valves Class-I, conforming to IS-778/1984 (Reaffirmed 2005) female ends, tested to 21.00 Kg/cm2. 80mm dia flanged
20Providing and fixing following check (non-return) valves Class-I, conforming to IS-778/1984 (Reaffirmed 2005) female ends, tested to 21.00 Kg/cm2. 100mm dia flanged
21Providing and fixing G. I. threaded Flange in G.I. Pipe line including cutting threading testing etc. complete (Old work) conforming to IS 1879. 50mm dia.
22Providing and fixing G. I. threaded Flange in G.I. Pipe line including cutting threading testing etc. complete (Old work) conforming to IS 1879. 100mm dia.
23Providing and fixing G. I. threaded Flange in G.I. Pipe line including cutting threading testing etc. complete (Old work) conforming to IS 1879. 150mm dia.
24Providing and fixing G. I. socket in G.I. Pipe line including cutting threading testing etc. complete (Old work) conforming to IS 1879. 50mm dia.
25Providing and fixing G. I. socket in G.I. Pipe line including cutting threading testing etc. complete (Old work) conforming to IS 1879. 100mm dia.
26Providing and fixing G. I. socket in G.I. Pipe line including cutting threading testing etc. complete (Old work) conforming to IS 1879. 150mm dia.
27Providing and fixing G. I. Elbow in G.I. Pipe line including cutting threading testing etc. complete (Old work) conforming to IS 1879. 50mm dia.
28Providing and fixing G. I. Elbow in G.I. Pipe line including cutting threading testing etc. complete (Old work) conforming to IS 1879. 100mm dia.
29Providing and fixing G. I. Union in G.I. Pipe line including cutting threading testing etc. complete (Old work) conforming to IS 1879. 50mm dia.
30Providing and fixing G. I. Union in G.I. Pipe line including cutting threading testing etc. complete (Old work) conforming to IS 1879. 100mm dia.
31Providing of High tensile MS Nut Bolts of required size and type, as per specifications with testing, including all lead and lifts, packing & forwarding charges for all components etc. complete.
32Providing, laying, jointing & field testing of High Density Polyethylene pipes, (HDPE) PE100 PN6 confirming to IS 4984/ 14151/ 12786/ 13488 with necessary jointing of pipes by electro fusion / butt welding process with all leads and lifts etc., complete. 75 mm dia
33Supply and laying, testing & commissioning of following sizes of copper conductor control cables on existing tray including fixing clamps & proper connections to equipment etc. complete as required. 4Cx 6 sq.mm
34Supplying and fixing flood light with high power LED of 3 to 6 Watt each assembled on single MCPCB and additional unique peanut lens on each LED, system lumens output with efficacy>120 lm/Watt. luminaire having color temp upto 6500K & 50000 hrs. burning life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF > 0.95 & surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flat glass, IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. 30Watt, color temp 3000-6500k as required. For gallery of Barna dam
35Supply of I.S.I. Marked iron clad / metal clad triple pole and neutral switch fuse (conduit entry ) /cable gland entry with two earthing terminals --63 Amps. 415/500 Volts.
36Supply of I.S.I. Marked iron clad / metal clad triple pole and neutral switch fuse (conduit entry ) /cable gland entry with two earthing terminals --100 Amps. 415/500 Volts.
37Supply of ISI Marked Automatic Star-Delta Starters confirming to IS : 13947-4 with suitable over load relay range and contactor\ size & timer 415 V , 3 -Phase with two earthing terminals 3 to 12.5 HP
38Supply and fixing of rechargeable inverter LED Bulb, reduces to 40-50% (emergency application) with Lithium Ion battery 2600mAh, backup upto 5 hrs. having color temp upto 6500K, IP-20 rating, THD (Total harmonic distortion) <20% 9W, Rechargeable Inverter LED Bulb
39Supply of rubber mat 2 x 1.0Mtr, 1100V tested
40Supplying and fixing of 4 Pole epoxy connector nut & bolt type, 30Amp. 500Volt. in existing box as required as per specification
41Supply and fixing of LT panel accessories of approved make in existing LT panel including connections etc. as required as per specification. Digital Ampere Metre with CTs with selector switch
42Supply and fixing of LT panel accessories of approved make in existing LT panel including connections etc. as required as per specification. Digital Volt Metre with selector switch & HRC fuse
43Repair maintenance of operation gallery door with fixing of locking system and mosquito net to prohibit entry of snakes etc. with G.I pipe and rod etc. with labour, material, tools, machinery etc. complete job at site. G.I pipe material up to 20 kg each gate (gate size 2mx2m)
44Repair maintenance and Servicing of control panel of room no. 1 & 2 of Barna power house & gallery including all material such as wires of required sq.mm., cables, lugs, tapping and rewiring of damaged wirings. Fixing of mccb, duct, clamps, V-A meter, T.V. terminals, push button with NONC, nut bolts, new panel lock with key etc. including wiring, testing and re-labeling (with radium) etc. complete labour with complete job for smooth and hassle free operation during flood in monsoon season including all material labour complete job Panel size 1.15mx1.90mx0.40m 2 no. control panel of gallery
45Supplying and fixing flood light with high power LED of 3 to 6 Watt each assembled on single MCPCB and additional unique peanut lens on each LED, system lumens output with efficacy>120 lm/Watt. luminaire having color temp upto 6500K & 50000 hrs. burning life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF > 0.95 & surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flat glass, IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. 60Watt, color temp 3000-6500k as required.For street light at Saddle dam and power house
46Supplying and fixing flood light with high power LED of 3 to 6 Watt each assembled on single MCPCB and additional unique peanut lens on each LED, system lumens output with efficacy>120 lm/Watt. luminaire having color temp upto 6500K & 50000 hrs. burning life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF > 0.95 & surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flat glass, IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. 150Watt, color temp 3000-6500k as required.For Gauge reader
47Supplying and fixing flood light with high power LED of 3 to 6 Watt each assembled on single MCPCB and additional unique peanut lens on each LED, system lumens output with efficacy>120 lm/Watt. luminaire having color temp upto 6500K & 50000 hrs. burning life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF > 0.95 & surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flat glass, IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. 250Watt, color temp 3000-6500k as required.For High mast
48Supply and fixing of multi core round FRLSH PVC insulated copper (flexible) conductor & PVC sheathed cables 1100Volts as per IS:694-1990 of approved make (56/0.3 mm) Three core 4.0 sq.mm.
49Supply of I.S.I. Marked iron clad / metal clad triple pole and neutral switch fuse (conduit entry ) /cable gland entry with two earthing terminals – 63 Amps. 415/500 Volts.
50Supply of rubber mat 2 x 1.0Mtr, 1100V tested
51Servicing of starter of saddle dam with changing of points, wiring etc., testing etc. for smooth and hassle free operation during irrigation including all material labour complete job
52Excision of tree’s branches under, above and near H.T. line, conductor wire, cable, power house, etc. excision of tree’s branches safely to prevent any damage to the conductor & power house from its falling and to ensure safety during execution of work at Barna dam to Saddle dam, Barna dam power house with complete labour and material etc. complete job
53Providing, supplying fixing with fabrication of G.I. sheet metal starter cover with locking system 0.5mx0.5mx0.2m with material and labour complete job at site
54Supply of rubber mat 2 x 1.0Mtr, 1100V tested
55Rewinding of fans by copper enameled wire of suitable gauge including all required material, insulation, varnishing, connection leads, oiling .greasing etc. complete with testing including dismantling & refitting of fan at site. Scrap old material is not returnable to the department. Ceiling fan 1200 mm sweep old model/cooler fan 500 mm (20\\")sweep
56Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Light point/fan points. Using modular accessories Primary medium point
57Cleaning, overhauling, servicing of ceiling/exhaust /wall bracket fan by applying grease & oil, including testing with mounting/hanging arrangement including replacement of safety pins, check nuts, lock nut, nut bolts etc. making perfect alignment & refitting at site as required.
58Supply and fixing as per specification Switch of approved make ISI marked with necessary material complete. 16/20Amp SP 250 Volt modular switch
5932 Amps D.P.250 Volt modular switch with indicator LED 2 Module
60Supply and fixing as per specification socket outlet of approved make & ISI marked with necessary material complete 10/16/20Amp 250 Volt 3 Pin modular type
61Supply and fixing of MPP condenser 250Volt single phase of approved make as required as per specification Condenser 4 mfd 250Volt
62Labor rate for rewiring a light/fan/twin control light/ socket out let on separate board/call bell point in rigid steel/rigid PVC nonmetallic conduit/PVC casing and capping in (open) surface conduit wiring system
63Supplying and erection of 11KV porcelain pin insulator complete with long steel head G.I. pin, nut, washer etc. as required
64Supplying and erection of 11KV porcelain disc insulator for 11KV overhead lines with galvanized insulator fittings, ball and socket type, and complete with galvanized strain clamp, bolts, nuts washer etc. as required.
65Chemical servicing of window/split air conditioning unit 1TR/1.5TR/2TR/3TR capacity including cleaning of cooling & condensing units, filters, grills etc& all other parts oiling & greasing of fan motor, testing of A.C unit etc.
66Gas charging (R410A/Eco Friendly Green Gas) of window/ split air conditioning unit including flushing of cooling &condensing units with nitrogen gas & rectification of leakage, replacement of filter, flair nut etc. if any 2.0 TR
67Supply of I.S.I. Marked iron clad / metal clad triple pole and neutral switch fuse (conduit entry ) /cable gland entry with two earthing terminals -- 16 Amps. 415/500 Volts.
68Supply of I.S.I. Marked iron clad / metal clad triple pole and neutral switch fuse (conduit entry ) /cable gland entry with two earthing terminals --63 Amps. 415/500 Volts.
69Supply of I.S.I. Marked iron clad / metal clad triple pole and neutral switch fuse (conduit entry ) /cable gland entry with two earthing terminals -- 100 Amps. 415/500 Volts.
70Supply of ISI Marked Automatic Star-Delta Starters confirming to IS : 13947-4 with suitable over load relay range and contactor\ size & timer 415 V , 3 -Phase with two earthing terminals ( for submersible pump) 3 to 12.5 HP
71Supply of ISI marked and approved make of moulded case circuit breaker (MCCB) suitable for 3 phase,3 pole, 50 Hz, 415 Volts, AC supply with respective interrupting capacity (KA) at 415 Volts cited against their range standard conforming to IS – 8828 MCCB 25kA current rating, 3P -25 to 100Amp & 80% - 100% adjustable
72Supply and fixing of multi core round FRLSH PVC insulated copper (flexible) conductor & PVC sheathed cables 1100Volts as per IS:694-1990 of approved make (56/0.3 mm) Three core 4.0 sq.mm.
73Servicing of control panel of room no. 1 & 2 of radial gate for smooth and hassle free operation during flood in monsoon season including all material such as wires of required sq.mm., cables, lugs, connector, tapping and rewiring of damaged wiring with providing, supplying & fixing of mccb, duct, clamps, V-A meter, push button with NONC, nut bolts, new panel lock with key etc. including wiring, testing and re-labeling (with radium) etc. complete labour with complete job. (2 Radial gate control panel)
74Rewinding and servicing of 10 H.P. Reverse Forward motor of gates including opening and refitting from hoist of radial gate
75Providing and supplying with fitting electromagnetic brake coil must be fitted in radial gate reverse forward 10 h. p. motor system with wiring, testing complete job at site 4 radial gate
76Tightening of loose conductor wire between two electric poles to prevent fault of conductor line from Barna Dam to saddle dam with providing and fixing of new bracket (with 4 insulator pin), clamps, insulator, conductor wire , jumper & nut bolt, washers etc. complete labour at site and as directed by engineer-in-charge.
77Supply and fixing street light with high power LED of 3 to 6 Watt each on existing bracket assembled on single MCPCB and additional unique peanut lens on each LED, system lumens output with efficacy>120 lm/Watt. luminiare having color temp upto 6500K & 50000 hrs. burning life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF> 0.95 & surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flat glass, IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347 i/c connection wire, testing etc. to complete the job. 60Watt, color temp 3000-6500k as required
78Supply and fixing Led tube rod comprising of LED tube with nonintegral/ integral driver, upto 6500K color temp having 40000 burning hrs life with minimum @ L 70, system lumen output should be minimum with system efficacy> 100 lm/Watt. LED driver PF> 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. Tube light LED 1 X 20/22Watt, Integral i/c batten aluminium body, PC diffuser.
79Supplying and replacement of cooler fan 500 mm (20\\") ISI marked with all necessary material including connection complete of approved as required
80Supply and replacement of ISI marked cooler submersible water pump complete with all necessary material including connection of approved make as required
81Supplying and fixing of 4 Pole epoxy connector nut & bolt type, 30Amp. 500Volt. in existing box as required as per specification
82Supply of XLPE insulated FRLS heavy duty power cable conforming IS-7098 (Part-1) 1988, 1100 Volt grade, 2/3/4/8/10/12 core ISI marked with copper stranded/ solid conductor. Armoured 2 core 6 sq. mm.
83Supply and erection of approved make safe earthing electrodeconsistingpipe-in-pipetechnologyasperIS3043-1987madeof corrosion free G.I. pipes with constant ohmic valuesurrounded by highly conductive compound with high chargedissipation suitable for effective and maintenance free earthingin earth pit of minimum bore dia. 150mm size, as mentioned below: With 2 metre G.I. pipes having outer pipe dia of 50mm having80-200 micron galvanizing, Inner pipe dia. of 25mm having200-250 micron galvanizing, connection terminal dia. of 12mmin nominal soil with 25 kg (one Bag) back filling bentonitecompound UL listed and confirm to relevantInternational/Indian standards around electrode upto groundlevel.
84Supplying&fixingoffireextinguisher/refillsasperIS specification ABCtypedulyrefilled6Kg&readytouse.
85SupplyoffiberdischargerodI/Cconnection copper leadtested
86Supply and fixing transformer breather with silica gel suitablefor100-500KVAasreqd
87Supplying and erection of 11KV porcelain pin insulator complete with longsteel head G.I.pin,nut,washer etc.as require.
88Supplying and erection of single piece nonlinear resistor typelighting arrestor (set of 3 nos) for 3 wire, 11KV overheadlines/sub-station with rated voltage of 9KV (rms) with anominal discharge current rating of 5 KA and complete with galvanized clamping arrangement,G.I.bolts,nuts,washer etc.asrequired.
89Supplying and erection of 11KV porcelain disc insulator for11KV overhead lines with galvanized insulator fittings, ball andsocket type, and complete with galvanized strain clamp, bolts,nuts washer etc. as required.
90Supply of firstaid box complete with medicine & bandage as per specification.
91Supply of hand gloves11KV tested
92Supplyofshockinstructionchartdulyframedwith glass,asreqd.
93Supplyofrubbermat2x1.0Mtr,1100Vtested
94Filtration of transformer oil for 33/0.4 KV, 11/0.4 KV3 phase 50 cycle oil immersed, naturally cooled,distribution transformer upto desired break down value.
95Supply and filling of new transformer oil of desired breakdown value for toppingasreqd.
96Supplying installing, testing & commissioning of outdoor H.T.,AB switch assembly set gang operated with brass contact parts,including required GI pipe operating rod, handle & lockingarrangement on OnOff position conforming to IS complete withrequired material and installing on existing DP structure tocomplete the job as required as per specification.(Set of 3 nos.)11 kv,400 Amp
97Supplying and fixing limit switch with accessories &arrangement on existing HT/LT structure/poles AB switchhandle for inter locking between distribution panel mainincomingLTswitchgear/systemasrequiredtocompletethe job
98Supplying&replacementofD.O.fusebarrelwithbrasspartsfor 33 or 11 KV i/c required fuse element according to load asper specification on existing D.P. structure as required 11KV
99Supplying installing, testing & commissioning D.O. fuseassembly with brass part contact for 33 or 11/0.4 KV DPStructure set of 3 Nos. with fuse barrel i/c required fuseelement&othermaterialsasperspecificationonexistingD.P. structureasrequired 11KV
100Collectionandspreadingofmetaldust,murumand40mm gradedhardmetalinsub-stationyardorasrequiredasmentioned below - Metaldust
101Collectionandspreadingofmetaldust,murumand40mm gradedhardmetalinsub-stationyardorasrequiredasmentioned below - Murum
102Supplyandfixingasperspecificationpendentholderof approvedmakeincludingflexiblecordupto3metrelength withnecessarymaterialscomplete
103SupplyandfixingasperspecificationSwitchofapproved make ISI marked with necessary material complete Surface switch 6Amp
104Supplyandfixingasperspecificationsocketoutletof approvedmake&ISImarkedwithnecessarymaterial complete 6Amp250Volt3Pinflushtype
105Supplyandfixingofapprovedmake3pinplugtopISI marked 6Amp250Volt3Pintop
106Supply andfixingLedtuberodcomprisingofLEDtubewith nonintegral/integral driver, upto 6500K color temp having 40000burninghrslifewithminimum@L70,systemlumen output should be minimum with system efficacy> 100 lm/Watt. LED driver PF> 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70. SubmissionLM79-08/IS16106(2012),IEC60598, IEC61347i/cconnection wire, testingetc.tocompletethe. TubelightLED1X20/22Watt,Integrali/cbattenaluminium body, PC diffuser. For power house & sub dn. Office
107SupplyandfixinginpositionLEDlampofapprovedmake forpowerhouse&subdn. Office 12 Watt250Volt
108Supplyandfixingofapprovedmakeflushtypestep type electronicfanregulatorincludingconnectionetc.as required on existing board 100 Watt for power House & Sub dn. Office 100 Watt
109Supplying and fixing flood light with high power LED of 3 to6 Watt each assembled on single MCPCB and additional uniquepeanutlensoneachLED,systemlumensoutputwith efficacy>120 lm/Watt. luminiare having color temp upto 6500K & 50000 hrs. burning life with minimum @ L 70, The colour rendering indexof LED light should be morethan 70. Luminiare comprises of driver, PF > 0.95 & surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flatglass, IP65 protection.SubmissionLM 79- 08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. 60Watt,colortemp3000-6500kasrequired.Forpower house&street light
110Rewinding of fans by copper enameled wire of suitable gaugeincludingallrequiredmaterial,insulation,varnishing, connectionleads,oiling.greasingetccompletewithtesting including dismantling & refitting of fan at site. Scrap old material is not returnable to the department Ceilingfan1200mmsweepoldmodel/coolerfan500mm (20\\")sweep
111Servicings&Maintainance of Control panels all mcb& bus barmany connection rusty and lose, carbon spot point allcoonection reconnect clean with electrical contact clenarandvoltmeter & Ammeter required for bus voltage and current ofcontrol panel , tagging & naming all panels & MCCB& requirednew lock system for control pane with material such as wireslugs ,push button & selector switchs control panel AC indicatorlamp ,MCCB Mounting & tapings for smooth and hassle freeoperationduringfloodinmonsoonseasonincludingallmaterial labour compelet job controlpanels-Size1.15mx1.90mx0.40m
112Servicings&Maintainance of Control panels all mcb& bus barmany connection rusty and lose, carbon spot point allcoonection reconnect clean with electrical contact clenarandvoltmeter & Ammeter required for bus voltage and current ofcontrol panel , tagging & naming all panels & MCCB& requirednew lock system for control pane with material such as wireslugs ,push button & selector switchs control panel AC indicatorlamp ,MCCB Mounting & tapings for smooth and hassle freeoperationduringfloodinmonsoonseasonincludingallmaterial labour compelet job 100KVADGSet-1&2changeover-0.5x.42x0.20M
113Servicings&Maintainance of Control panels all mcb& bus barmany connection rusty and lose, carbon spot point allcoonection reconnect clean with electrical contact clenarandvoltmeter & Ammeter required for bus voltage and current ofcontrol panel , tagging & naming all panels & MCCB& requirednew lock system for control pane with material such as wireslugs ,push button & selector switchs control panel AC indicatorlamp ,MCCB Mounting & tapings for smooth and hassle freeoperationduringfloodinmonsoonseasonincludingallmaterial labour compelet jobThreephasepowerfactorcontroller-0.96x0.70mx0.2M
114Servicings&Maintainance of Control panels all mcb& bus barmany connection rusty and lose, carbon spot point allcoonection reconnect clean with electrical contact clenarandvoltmeter & Ammeter required for bus voltage and current ofcontrol panel , tagging & naming all panels & MCCB& requirednew lock system for control pane with material such as wireslugs ,push button & selector switchs control panel AC indicatorlamp ,MCCB Mounting & tapings for smooth and hassle freeoperationduringfloodinmonsoonseasonincludingallmaterial labour compelet job 62KVADGSetChangeover-0.54x0.36M
115Servicings&Maintainance of Control panels all mcb& bus barmany connection rusty and lose, carbon spot point allcoonection reconnect clean with electrical contact clenarandvoltmeter & Ammeter required for bus voltage and current ofcontrol panel , tagging & naming all panels & MCCB& requirednew lock system for control pane with material such as wireslugs ,push button & selector switchs control panel AC indicatorlamp ,MCCB Mounting & tapings for smooth and hassle freeoperationduringfloodinmonsoonseasonincludingallmaterial labour compelet job 62KVADGSetControlpanel-0.84x0.5x0.25M
116Servicings&Maintainance of Control panels all mcb& bus barmany connection rusty and lose, carbon spot point allcoonection reconnect clean with electrical contact clenarandvoltmeter & Ammeter required for bus voltage and current ofcontrol panel , tagging & naming all panels & MCCB& requirednew lock system for control pane with material such as wireslugs ,push button & selector switchs control panel AC indicatorlamp ,MCCB Mounting & tapings for smooth and hassle freeoperationduringfloodinmonsoonseasonincludingallmaterial labour compelet job100KVA1&2DGSetcontrolpanel-0.7x0.6x0.25M
117Complete shutdown, isolation safety arrangement oftransformerand pressure washing & degreasing of fulltransformer body and radiators , radiator fin cleaning(air/water jet)oil leakage detection & arresting , gasket changebolt tightening sealant minor welding ), rust removal wirebrushing surface preparation and red oxide primer single coat& synthetic/PU enamel paint double coats and labour , toolstackles scaffolding consumables .
118Supply and fixing of rechargeable inverter LED Bulb, reduces to40-50% (emergency application) with Lithium Ion battery2600mAh,backup upto 5 hrs. havingcolor temp upto 6500K,IP-20 rating, THD (Total harmonic distortion) <20% 9W,RechargeableInverterLEDBulb
119Supplying of ISI marked and approved make of moulded casecircuitbreaker(MCCB)suitablefor3phase&N,4pole,50Hz, 415 Volts, (Ics=100%Icu) AC supply with thermal-magneticrelease having respective breaking capacity (KA) at 415 VoltscitedagainsttheirrangestandardconformingtoIS/IEC60947- 2 MCCB25kAcurrentrating-63to100Amp&adjustableoverloadsetting80%-100%ofIn,adjustableshortcircuit setting6-10In4Pole
120MCCB25kAcurrentrating-125Amp&adjustableoverloadsetting80%-100%ofIn,adjustableshortcircuitsetting6-10 In4Pole
121MCCB 25kA current rating - 160Amp & adjustable overloadsetting80%-100%ofIn,adjustableshortcircuitsetting6-10In 4 Pole
122Supply and fixing Crimping type alum lugs as per ISSspecification suitable for following size of cable withalu./copper solid /stranded conductor evenly crimped withhigh/pressuretoolandconnectedtoseitchgear/bus/ MCCB/MCBetc.asrequiredcomplete 95sqmm
123Supply and fixing Crimping type alum lugs as per ISSspecification suitable for following size of cable withalu./copper solid /stranded conductor evenly crimped withhigh/pressuretoolandconnectedtoseitchgear/bus/ MCCB/MCBetc.asrequiredcomplete 70sq.mm
124Supply and fixing Crimping type alum lugs as per ISSspecification suitable for following size of cable withalu./copper solid /stranded conductor evenly crimped withhigh/pressuretoolandconnectedtoseitchgear/bus/ MCCB/MCBetc.asrequiredcomplete 180 sq. mm
125Supply and fixing Crimping type alum lugs as per ISSspecification suitable for following size of cable withalu./copper solid /stranded conductor evenly crimped withhigh/pressuretoolandconnectedtoseitchgear/bus/ MCCB/MCBetc.asrequiredcomplete 240 sq.mm
126SupplyofI.S.I.Markedironclad/metalcladtriplepoleandneutralswitchfuse(conduitentry)/cableglandentrywith twoearthingterminals 63Amps.415/500Volts
127Supply of I.S.I.Marke dironclad/metalcladtriplepoleandneutralswitchfuse(conduitentry)/cable glandentry with twoearthing terminals 200Amps.415/500Volts
128Supply of battery connector for 12v battery. Brass/copper
129Supply and fixing as per specification socket outlet of approved make & ISI marked with necessary material complete 10/16/20Amp 250 Volt 3 Pin modular type
130Supply and fixing of MPP condenser 250Volt single phase of approved make as required as per specification Condenser 4 mfd 250Volt
131Buy Back of Old part(Sacrapmaterial) MCCB comeout during repair and maintenance work Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56290544
AUTHORITY Government Departments
TENDER VALUE 15.86 Lakhs
LAST DATE 17-07-2026
Authority
Authority Name Water Resources Department
Work Description Tender for Repair Maintenance Work Of Mechanical Units And Electrical Repair & Maintenance Of Radial Gate Control Panels, Rest House, Power House And Illumination Arrangement At Crest Of Barna Dam And Saddle Dam Bari For The Year 2026-27 (Second Call)
Basic Detail
Tender No 641/2026-27
Bidding Type Tender
Location
City Hoshangabad
State Madhya Pradesh
Key Dates
Publish Date 03 Jul 2026
Submission Date 17 Jul 2026
Open Date 20 Jul 2026
Finance
Tender Value 15.86 Lakhs
Tender Fee 2000
EMD 31732
Exemption Not Available
Document List
506062_1.pdf
8b1879b0-7557-4b9d-81c8-747c154270e5.html
BOQ_625504.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Jul 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
pdf

506062_1.pdf

html

8b1879b0-7557-4b9d-81c8-747c154270e5.html

xls

BOQ_625504.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders