Youth Affairs and Sports and Culture Government Departments Closing in 8 days TDR #56290463

Tender For Upgradation Of Sports Infrastructure Facilitiesat Govt. Model Higher Secondary School, Varkala, Thiruvananthapuram - Balance Work - Retender

Issued by Government Departments · Thiruvananthapuram, Kerala
Tender Value
10.30 Lakhs
Estimated cost
Bid Submission
13 Jul 2026
8 days left
EMD
25751
Bank guarantee accepted
Document Fee
2950
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvananthapuram → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Upgradation Of Sports Infrastructure Facilitiesat Govt. Model Higher Secondary School, Varkala, Thiruvananthapuram - Balance Work - Retender

BOQ

Name of Work:- Upgradation of Sports Infrastructure Facilitiesat Govt. Model Higher Secondary School, Varkala, Thiruvananthapuram - Balance work - Retender
Sl. No. Item Description
1Ground Development and Construction of Mud Court (CPWD)
2od303097/2022_2023 : SKF_OD 7/2022-2023 Supplying and stacking for measurement sieved red earth at site including royalty and carriage upto 5 k.m. lead complete.
3od240369/2022_2023 : SKF_OD 4/2022-2023 Supplying and stacking for measurement Sieved Jamuna Sand at site including cost of sand and carriage upto 5 k.m. lead complete.
4od240370/2022_2023 : SKF_OD 2/2022-2023 Mixing earth and jamuna sand in the required proportion specified or directed by the Officer-in-charge
5od240371/2022_2023 : SKF_OD 3/2022-2023 Spreading of earth and jamuna sand in required thickness as per direction of officer-in-charge (cost of earth and jamuna sand to be paid separately).
6od240372/2022_2023 : SKF_OD 10/2022-2023 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity with road roller including making good the undulations etc. including all cost of labour, hire charges, fuel, oil, etc. complete.
713.88 : Removing white or colour wash by scrapping and sand papering and preparingthe surface smooth including necessary repairs to scratches etc. complete
813.48.1 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
913.99.1 : Painting with synthetic enamel paint of approved brand and manufacture ofrequired colour to give an even shade :One or more coats on old work
10od240373/2022_2023 : Supply and installing Football goal post , premium quality including all fittings such as net,hooks etc for 7s court.
11Stacking and sieving for measurement sieved red earth at site
12Filling of ground (MoRTH)
1312.8.1.C.1 : Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications RCC Grade M20 - Using Concrete Mixer
1412.40 : Supply, Fitting and Placing un- coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications
15Fencing Works (CPWD)
16od12494/2023_2024 : Supply and Installation of approved quality 2mm thick UV Stabilized Nylon net of Mesh size not greater than 50mm in existing GI poles including all charges as per the direction of Engineer in charge.
17Electrification works
181.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1990.15.3.4 : Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III double arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 6 Meters
2090.15.4.3 : Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
2190.6.4.54 : Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.10.00 sq.mm 4 Run
221.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
231.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
241.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
2590.11.1.14 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
262.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
272.10.5 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral
282.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2990.12.10.2 : Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation 50/38 mm or nearest size
3090.12.5.38 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 4 core 4 sq mm
3190.12.5.1 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 2 core 4 sq mm
32od16095/2023_2024 : Supply and fixing SINTEX Box (150mmx150mmx100mm) including connector, MCB Rail and neutral links for giving connections including all accessories complete as required
3390.6.5.11 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 3 core 1.50 sqmm
345.1 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
3590.16.1.2 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
36od16592/2023_2024 : Design,Supply, installation, testing and commissioning of outdoor duty (IP 54) wall mounted type weatherproof , type KSEB metering panel , suitable for accomodating KSEB energy meter ( supply of energy meter is under KSEB scope) with locable door having glass window, sealing facility for KSEB, top cover and necessary overhang, undergone seven tank process ,powder coated finish and all mounting accessories as required complete .Three phase energy meter with isolation units and controller as required Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56290463
AUTHORITY Government Departments
TENDER VALUE 10.30 Lakhs
LAST DATE 13-07-2026
Authority
Authority Name Department Of Sports And Youth Affairs
Work Description Tender for Upgradation Of Sports Infrastructure Facilitiesat Govt. Model Higher Secondary School, Varkala, Thiruvananthapuram - Balance Work - Retender
Basic Detail
Tender No 597/SKF/CE/2025-26
Bidding Type Tender
Location
City Thiruvananthapuram
State Kerala
Key Dates
Publish Date 03 Jul 2026
Submission Date 13 Jul 2026
Open Date 15 Jul 2026
Finance
Tender Value 10.30 Lakhs
Tender Fee 2950
EMD 25751
Exemption Not Available
Document List
0ab26cb8-c2bd-49c8-9f4e-349b47291017.html
BOQ_1452236.xls
DWG.pdf
Tenderdoc.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Jul 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

0ab26cb8-c2bd-49c8-9f4e-349b47291017.html

xls

BOQ_1452236.xls

pdf

DWG.pdf

pdf

Tenderdoc.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders