Tender For Through Repairing & Replacement Of Damaged And Burnt Out Spare Parts Of Motor Starter Panel Of Swf Pump Unit No-2 With Other Allied Works At Topsia Drainage Pumping Station.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
14 Jul 2026
5 days left
EMD
6000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Through Repairing & Replacement Of Damaged And Burnt Out Spare Parts Of Motor Starter Panel Of Swf Pump Unit No-2 With Other Allied Works At Topsia Drainage Pumping Station.
BOQ
| Sl. No. | Item Description |
| 1 | TOTAL |
| 2 | Dismantling all existing accessories from the existing panel. |
| 3 | Thorough cleaning the existing starter panel by the petrol / CTC etc, in usual method and as per direction of EIC |
| 4 | Supply fixing of stud type LED indicating lamp (110 to 230Volt) (For phase & ON/OFF indication) |
| 5 | Internal power circuit wiring including necessary connection with 1.1 KV grade 1.5 sq mm PVC insulated single core Cu Flexible wire (make Finolex/ KDK) |
| 6 | Supply, delivery, fitting , fixing of 3 Pole Power Contactors - Type MNX-550, Aux. Contacts 2 NO + 2 NC, AC3 Rating 550 (A), AC1 Rating 650 (A) , Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 (L&T / ABB / SCHNEIDER or reputed make) |
| 7 | Supply of aluminium flat busbar for electrical power distribution. |
| 8 | Supplying and fixing the terminal connector having drill holes for inserting S.S stud of 8.5 mm dia and connection point of existing copper wires of overall dimension 65mm long x25mm square shape. |
| 9 | supply and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture oproof entry of xlpe / pvc armored cables up to 35 sq. mm (3 core) & Finishing the end of the cable by crimping method including fixing of dowell's shoulderlesas socket tapes and other jointing materials. |
| 10 | Supplying and fixing single-door MS vertical Distribution Board 12 way , 160 amps with powder coated paint and IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. |
| 11 | supply delivery, fitting, fixing of bakelite assembly by replacing existing old damaged contact assembly. |
| 12 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials. 3 core 120 sqmm cable |
| 13 | Supply, delivery, fitting & fixing of star-delta timer ST 100 (range 3 sec -120sec /240-415VAC 1NO+1NC) L&T/ABB/SCHNEIDER or reputed make |
| 14 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as 120 sqmm × 3 core. |
| 15 | Supply , Delivery & Fitting, Fixing of 3 pole (100 Amp), 415 Volt , Spreader Terminals. |
| 16 | Supply of analog Square Ammeter (AE/ reputed make) as per existing specification and C.T. Ratio & Earth fault relay ( 230V COIL, 80 A-500A ) , (LEGRANDS / ABB/ MINILAC make). |
| 17 | Supply of single phase preventor( 240V / 415V) reputed make (L&T /MINILAC) |
| 18 | Supplying of following XLPE insulated aluminium conductor armored cables of 1.1 KV grade as per IS7098 (PART1) 1988 with upto date amendments. (RATE IN RS. PER MTR) Conductor Cross section in SQ MM 16 core 4. |
| 19 | Laying through underground trench. (A) Laying of one NO. cable upto 35 SQMM in underground trench 460 MM wide X 760 MM average depth, with brick protection on the top of the cable with 8 (EIGHT) nos. bricks per meter, including filling the space between the bricks & cable and also the trench with shifted soil, leveling UP and restore surface duly rammed. |
| 20 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as require Up To 50 m.m (IN RUNNING METER) |
| 21 | Final running test to be done in full load after re-fixing all the Eletrical acessorie & instruments properly with the panels. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysJul 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender