Power Government Departments Closing in 6 days TDR #56289798

Tender For The Work Of Releasing Power Supply To M/S. Central Industrial Security Force, Cisf 6Th Rb Battalion At Tuem- Pernem At 33 Kv Level For A Total Load Of 2,800 Kva Under The Jurisdiction Of Sub Division-I, Pernem, Division- Xvii, Mapusa.

Issued by Government Departments · goa, Goa
Tender Value
2.99 Crore
Estimated cost
Bid Submission
17 Jul 2026
6 days left
EMD
5.98 Lakhs
Bank guarantee accepted
Document Fee
1500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
goa → Goa
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for The Work Of Releasing Power Supply To M/S. Central Industrial Security Force, Cisf 6Th Rb Battalion At Tuem- Pernem At 33 Kv Level For A Total Load Of 2,800 Kva Under The Jurisdiction Of Sub Division-I, Pernem, Division- Xvii, Mapusa.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 09-Jul-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 17-Jul-2026

BOQ

Name of Work:- The work of releasing power supply to M/s. Central Industrial Security Force, CISF 6th RB Battalion at Tuem- Pernem at 33 KV level for a total load of 2,800 KVA under the jurisdiction of Sub Division-I, Pernem, Division- XVII, Mapusa.
Sl. No. Item Description
1COST OF MATERIAL
2XLPE cable 33KV 3C X 400 sq.mm armoured type A2XFY for 900 mtr (Double run)
3XLPE cable 33KV 3C X 300 sq.mm armoured type A2XFY for 100 mtr
43 WAY RMU, 33 KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB : Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) IAC-AFLR 25 KA is for SF6 tank and cable work, 630 A with no darating @ 50 deg C and VCB making capacity of 62.5 KA with INGI enclosure with manual operated earthing switches in SF6 and 2 VCB with electrical closing and tripping along with disconnector and earthing switches SCADA competable. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Current transformer and numerical relay with communication in all CB module. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.Auxiliary PT as per specification shall be provided in RMU.
5Numbering of RMUs and poles with paint
6GI Flat 50 x 6 mm
7Class B, 100 mm dia nominal bore, 3000 mm long pipe earth electrodes with test Connection links having welded flat of size 50 x 6 mm for connecting earth strip, RCC chamber, CI cover hinged to CI frame, other accessories as per Technical specs, alongwith required quantity of charcoal, salt etc or Bentonite to be buried below ground and to be connected with earth mat of MS Flat. i.e. Chemical Earthing.
8H. S. 33KV touch proof Temination Kit for 33 KV RMU of ABB make
9H.S. 33 KV straight through joint 3 C x 400 sq.mm. XLPE
10Modem for Automatic Meter Reading (CAMR)
1133 KV Metering cubicle complete
12Life Extension and Reliability Enhancement of 33 KV Outdoor metering cubiclei) Epsilon High dielectric strength 15 KV tape on bus bars (1.8 m) and joints in 63 mm and 25 mm widths as requiredii) Epsilon G4 Elektrosafe Non-flammable coating on epoxy / ceramic insulators and CT and PT for flashover risk reductioniii) Epsilon G4 Elektrosafe Non-flammable high diaelectic strength coating on inner panel walls in high-risk segments for reducing flashover riskiv) Epsilon G 4 External surface coating for marine grade corrosion prevention
13Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in hard rock where blasting prohibited (of size 1.3 x 0.6 x 900 Mts)
14Supplying and filling in plinth under floors, trenches including watering ramming consolidating, dressing, complete, sand (of size 0.2x 0.6 x 900)
15Deduct for 33 KV Cable ( 3.14x0.05x0.05)x total length x no. of run
16Deduct for bricks (0.2x0.1x0.1)x no. of bricks
17Total Sand
18Supply and laying of RCC protective covers of size 600mm long x 250mm width and 50mm thick capable of bearing load of 135Kg. And covered with earth/ sand upto depth of 0.15mts. Confirming to IS 1255-1967 at non-road crossing.
19Bricks class design 75 kg/cm2 (1st class wire cut)
20warning Tape
21Supply and installing of cable route Markers (for entire route length) [Proposed one for every 10 mtrs]
22COST OF ERECTION
23XLPE cable 33KV 3C X 400 sq.mm armoured type A2XFY for 900 mtr (Double run)
24XLPE cable 33KV 3C X 300 sq.mm armoured type A2XFY for 100 mtr
253 WAY RMU, 33 KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB : Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) IAC-AFLR 25 KA is for SF6 tank and cable work, 630 A with no darating @ 50 deg C and VCB making capacity of 62.5 KA with INGI enclosure with manual operated earthing switches in SF6 and 2 VCB with electrical closing and tripping along with disconnector and earthing switches SCADA competable. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Current transformer and numerical relay with communication in all CB module. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.Auxiliary PT as per specification shall be provided in RMU.
26GI Flat 50 x 6 mm
27Class B, 100 mm dia nominal bore, 3000 mm long pipe earth electrodes with test Connection links having welded flat of size 50 x 6 mm for connecting earth strip, RCC chamber, CI cover hinged to CI frame, other accessories as per Technical specs, alongwith required quantity of charcoal, salt etc or Bentonite to be buried below ground and to be connected with earth mat of MS Flat. i.e. Chemical Earthing.
28H.S. 33 KV straight through joint 3 C x 400 sq.mm. XLPE
2933 KV Metering cubicle complete
30Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in hard rock where blasting prohibited (of size 1.3 x 0.6 x 900 Mts)
31Re filling the pipeline foundation trenches plinth sides foundation etc with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by the engineer in Charge (of size 1.1 x 0.6 x 900)
32Deduct for RCC slab - [(0.6*0.25*0.05)*no of slabs]
33Total Reffiling
34Supply and laying of RCC protective covers of size 600mm long x 250mm width and 50mm thick capable of bearing load of 135Kg. And covered with earth/ sand upto depth of 0.15mts. Confirming to IS 1255-1967 at non-road crossing.
35Bricks class design 75 kg/cm2 (1st class wire cut)
36warning Tape
37Supply and installing of cable route Markers (for entire route length) [Proposed one for every 10 mtrs]
38CIVIL WORKS
39Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 min width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : All kinds of soil
40Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.
41Providing & laying cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: All works upto plinth level
42Providing and laying in position (1:11/2:3) Reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand: 3 graded stone agg 20mm nominal size): All works upto plinth level
43Providing TMT steel reinforcement bars of (SAIL, TATA, VIZAG, JSW Steel Ltd.))(Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in allthe floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member.
44Centering & shuttering including Strutting, Propping & removal of forms for:
45Foundations, Footings, Bases for columns
4612mm cement plaster 1:4 (1 cement : 4 fine sand)
47Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56289798
AUTHORITY Government Departments
TENDER VALUE 2.99 Crore
LAST DATE 17-07-2026
Authority
Authority Name Department Of Electricity
Work Description Tender for The Work Of Releasing Power Supply To M/S. Central Industrial Security Force, Cisf 6Th Rb Battalion At Tuem- Pernem At 33 Kv Level For A Total Load Of 2,800 Kva Under The Jurisdiction Of Sub Division-I, Pernem, Division- Xvii, Mapusa.
Basic Detail
Tender No 11(26-27)/1530 Dt01/07/2026
Bidding Type Tender
Location
City goa
State Goa
Key Dates
Publish Date 09 Jul 2026
Submission Date 17 Jul 2026
Open Date 18 Jul 2026
Finance
Tender Value 2.99 Crore
Tender Fee 1500
EMD 5.98 Lakhs
Exemption Not Available
Document List
41d42048-e85c-48bc-b973-eba32d0e399a.html
BOQ_30492.xls
Tendernotice_1 (11).pdf
Tendernotice_2 (4).pdf
Tendernotice_3 (1).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 17, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 6 days
Jul 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Jul 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

41d42048-e85c-48bc-b973-eba32d0e399a.html

xls

BOQ_30492.xls

pdf

Tendernotice_1 (11).pdf

pdf

Tendernotice_2 (4).pdf

pdf

Tendernotice_3 (1).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders