Coal and Mines Boards / Undertakings / PSU Closing in 11 days TDR #56286935

Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - As Per Nit; Retro Fitment Of Vfd Drive With Existing Dol Panel Including Integration With Lcss Plc In Both Fps In Processing Plant As Mentioned In N

Issued by Boards / Undertakings / PSU · Panna, Madhya Pradesh
Tender Value
6.89 Lakhs
Estimated cost
Bid Submission
17 Jul 2026
11 days left
EMD
6900
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Panna → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - As Per Nit; Retro Fitment Of Vfd Drive With Existing Dol Panel Including Integration With Lcss Plc In Both Fps In Processing Plant As Mentioned In Nit; As Per Nit - Supply & Retrofitment Of 11Kw Drive Suitable To Control 4.2 Kw Vibrator Motors X 2 Nos Vfd Capacity 12Kw, 15Hp, 3 Phase Output Current 23 S With Work Involving Integrating Existing Facility Of Local Control Station /Dcs Control Interfacing And Associated Wiring As Per The Site Requirement Of Processing Plant Feed And Float Screen Of Dmp, Panna. , Supply & Retrofitment Of Vfd Input Copper Choke Suitable For 11Kw, 15Hp, 23 S, 3 Phase , Supply & Retrofitment Of Dynamic Braking Resistor 1.5Kw, 52 Ohms , Supply Of 5.5 Kw Mpcb – Schneider Gv2me14 , Engineering With Retrofitment Of Vfd And Dol Controls To Plc With Digital/Analog Signals & Modbus Rtu Connectivity (Supply Of Interface Card If Any, Deemed Included) , Supply & Lying Of Frls Armoured Copper Cable 4C × 2.5 Sq.Mm

BOQ

Sl. No. Item TitleItem Description
1Supply & retrofitment of 11KW Drive suitable to control 4.2 KW Vibrator Motors X 2 Nos VFD Capacity 12KW, 15HP, 3 Phase output current 23 Amps with work involving integrating existing facility of local control station /DCS Control Interfacing and associated wiring as per the site requirement of Processing Plant Feed and Float Screen of DMP, Panna.Supply & retrofitment of 11KW Drive suitable to control 4.2 KW Vibrator Motors X 2 Nos VFD Capacity 12KW, 15HP, 3 Phase output current 23 Amps with work involving integrating existing facility of local control station /DCS Control Interfacing and associated wiring as per the site requirement of Processing Plant Feed and Float Screen of DMP, Panna.
2Supply & retrofitment of VFD Input Copper Choke suitable for 11KW, 15HP, 23 Amps, 3 PhaseSupply & retrofitment of VFD Input Copper Choke suitable for 11KW, 15HP, 23 Amps, 3 Phase
3Supply & retrofitment of Dynamic Braking Resistor 1.5KW, 52 OhmsSupply & retrofitment of Dynamic Braking Resistor 1.5KW, 52 Ohms
4Supply of 5.5 KW MPCB – Schneider GV2ME14Supply of 5.5 KW MPCB – Schneider GV2ME14
5Engineering with retrofitment of VFD and DOL controls to PLC with digital/analog signals & Modbus RTU connectivity (Supply of interface card if any, deemed included)Engineering with retrofitment of VFD and DOL controls to PLC with digital/analog signals & Modbus RTU connectivity (Supply of interface card if any, deemed included)
6Supply & lying of FRLS Armoured Copper Cable 4C × 2.5 Sq.mmSupply & lying of FRLS Armoured Copper Cable 4C × 2.5 Sq.mm

AI Tender Summary

OUR REF NO 56286935
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 6.89 Lakhs
LAST DATE 17-07-2026
Authority
Authority Name Nmdc Limited
Work Description Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - As Per Nit; Retro Fitment Of Vfd Drive With Existing Dol Panel Including Integration With Lcss Plc In Both Fps In Processing Plant As Mentioned In Nit; As Per Nit - Supply & Retrofitment Of 11Kw Drive Suitable To Control 4.2 Kw Vibrator Motors X 2 Nos Vfd Capacity 12Kw, 15Hp, 3 Phase Output Current 23 S With Work Involving Integrating Existing Facility Of Local Control Station /Dcs Control Interfacing And Associated Wiring As Per The Site Requirement Of Processing Plant Feed And Float Screen Of Dmp, Panna. , Supply & Retrofitment Of Vfd Input Copper Choke Suitable For 11Kw, 15Hp, 23 S, 3 Phase , Supply & Retrofitment Of Dynamic Braking Resistor 1.5Kw, 52 Ohms , Supply Of 5.5 Kw Mpcb – Schneider Gv2me14 , Engineering With Retrofitment Of Vfd And Dol Controls To Plc With Digital/Analog Signals & Modbus Rtu Connectivity (Supply Of Interface Card If Any, Deemed Included) , Supply & Lying Of Frls Armoured Copper Cable 4C × 2.5 Sq.Mm
Basic Detail
Tender No GEM/2026/B/7739669
Bidding Type Tender
Location
City Panna
State Madhya Pradesh
Key Dates
Publish Date 03 Jul 2026
Submission Date 17 Jul 2026
Open Date 17 Jul 2026
Finance
Tender Value 6.89 Lakhs
Tender Fee Ref. Documents
EMD 6900
Exemption Not Available
Document List
bb8664f8-120d-4a53-887f-868ae157088d.pdf
1783055825.xlsx
1783055848.pdf
1783055852.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Jul 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
pdf

bb8664f8-120d-4a53-887f-868ae157088d.pdf

xlsx

1783055825.xlsx

pdf

1783055848.pdf

pdf

1783055852.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders