Tender for rate contract for surgical items and suture items at srg hospital jhalawar
Tender Overview
Project Description
rate contract for surgical items and suture items at srg hospital jhalawar , srg hospital , nonabsorbable polypropylene light weight macroporous mesh , three dimensional monofilament polyester composite mesh with collagen with glycerol anti adhesive barrier visceral side and stay suture in parietal side along with medial medial , three dimensional monofilament polyester composite mesh with collagen with glycerol anti adhesive barrier visceral side and stay suture in parietal side along with medial medial , three dimensional monofilament polyester composite mesh with with collagen with glycerol anti adhesive barrier visceral side and stay suture in parietal side along with medial medial , absorbable 5 mm hernia mesh fixation device 30 screw shaped with proximal wings of pgla tacks of 4.1 mm length along with flexible shaft up to 3 cm. , absorbable 5 mm hernia mesh fixation device 15 screw shaped with proximal wings of pgla tacks of 4.1 mm length along with flexible shaft up to 3 cm. , non absorbable 5 mm hernia mesh fixation device with 30 helical shaped titanium tacks 3.96mm width and 0.61 mm diameter , 5mm nonabsorbable helical fastener made up of medical grade stainless steel covered with atraumatic polymer (peek) cap to avoid metal exposure with 15 fasteners , 5mm nonabsorbable helical fastener made up of medical grade stainless steel covered with atraumatic polymer (peek) cap to avoid metal exposure with 30 fasteners , light weight monofilament polypropylene mesh, design to confirm inguinal anatomy, 3d shape , light weight monofilament polypropylene mesh, design to confirm inguinal anatomy, 3d shape , light weight monofilament polypropylene mesh, design to confirm inguinal anatomy, 3d shape , light weight monofilament polypropylene mesh, design to confirm inguinal anatomy, 3d shape , battery operated 60mm articulating endo cutter with a disposable battery pack, for enhanced distal tip stability while firing, having closed channel in the cartrdige jaw for better stability during firing, 360 degree rotation shaft and one handed natural articulation up to 45 degrees, precision machined anvil to deliver initial, system wide compression, wide proximal to distal jaw aperture (proximal 8mm , distal 22mm) , 3 point gap control for alignment and calibration throughout the 60 mm staple line, knife direction/reverse control to discontinue the firing and return the knife, interchangeable 6 row cartridge options of white, blue ,gold, green and black, all fits down to 12mm trocar sleeve, 440 mm shaft length - 60 mm stapler , linear cutter 55mm with six rows, 3d staple formation, option of closed staple height of 1.5mm/1.8mm/2mm in one cartridge only , linear cutter 75mm with six rows, 3d staple formation, option of closed staple height of 1.5mm/1.8mm/2mm in one cartridge only , universal linear cutter cartridge 75mm open linear cutter compatible with selectable staple height linear cutter 75mm.option of closed staple height of 1.5mm/1.8mm/2mm in one cartridge only. 6 rows 3-d staple technology. , universal linear cutter cartridge 55mm for open linear cutter compatible with selectable staple height linear cutter 55mm.option of closed staple height of 1.5mm/1.8mm/2mm in one cartridge only. 6 rows 3-d staple technology. , curved cutter stapler 40 mm linear cutter simultaneous cutting and stapling , curved green cartridge having close staple height of 2.0 mm, tactile feedback on completion of firing sequence, new anvil, knife with every catridge , powered circular stapler 29 mm with 3d staple and not slip grip , powered circular stapler 31mm with 3d staple and not slip grip , circular stapler 33mm with controlled tissue compression with adjustable staple height (1.0-2.5 mm) for controlled tissue compression, longer staple leg 5.5mm & non slip grip surface , laparoscopic cartridge for stapler 60 mm blue, 1.5 mm closed staple height with gripping surface technology and six rows compatible with all range of endoscopic linear cutter 60mm , laparoscopic cartridge for stapler 60 mm green, 2.0 mm closed staple height with gripping surface technology and six rows compatible with all range of endoscopic linear cutter 60mm , pph stapler 33mm - hemorrhoidal stapler kit consists of 33mm hemorrhoidal circular stapler (with fixed anvil, adjustable closed staple height from 0.75 mm – 1.5 mm, staple open leg length of 5.5 mm), suture threader, circular anal dilator, purse-string suture anoscope, suture for purse string. , optically guided bladeless trocar 12mm with bilateral tissue separators, optical tip to eliminate blind entry, clear ribbed cannula to enhance abdominal wall retention, recessed stopcock valve, funnel shaped housing, duckbill secondary seal, integrated universal seal that eliminates the use of reducer, 150mm length. , optically guided bladeless trocar 12 mm with bilateral tissue separators, optical tip to eliminate blind entry, clear ribbed cannula, recessed stopcock valve, funnel shaped housing, duckbill secondary seal, integrated universal seal that eliminates the use of reducer length 100mm. , facial closure device contain - optical bladeless trocar with facial closure device comaptible with clear cannula have two side opening meant for uniform port closure , varied staple height reloads/cartridges for 60 mm gia instruments with tri-staple technology, with the cutting knife blade incorporated in the reloads itself, with purple varied staple height of 3, 3.5 and 4mm leg length , varied staple height reloads/cartridges for 80 mm gia instruments with tri-staple technology, with the cutting knife blade incorporated in the reloads itself, with purple varied staple height of 3, 3.5 and 4mm leg length , linear cutter with varied staple height, tri-staple technology-enabled reloads integration with left and right firing knob(both side firing) ,linear cutter stapler with integrated gap control technology in 60 mm tristaple gia stapler, compatible with tri-staple gia 60 mm open linear cutter reloads/cartridges purpule and black , eea circular stapler purple colour medium thick , triple row with tristaple technology (three row of staple inner to outer row 3.0,3.5 and 4.0 mm with sloped cartridges face in one stapler) diameter 31mm , linear cutter with varied staple height, tri-staple technology-enabled reloads integration with left and right firing knob(both side firing) ,linear cutter stapler with integrated gap control technology in 80 mm tristaple gia stapler, compatible with tri-staple gia 80 mm open linear cutter reloads/cartridges purpule and black , wound protector with double ring in small 2.5-6 cm usfda approved , wound protector with double ring in medium 5-9 cm , wound protector with double ring in large in size 9-14 cm usfda approved , endo catch specimen removal kit:with continuous ring ,polyurethane pouch with 34.5 cm shaft length , 10mm with leakproof and impervious material to cancer cells of 0.5 microns/ pretied purse string on pouch usfda approved , disposable laparoscopic clip applier preloaded with 16 clips, 5mm diameter with clip logic technology and digital display titanium clips- u shaped , laparoscopic liner cutter without integrated fresh knife with 360*rotation & 0-45* articulation in both direction : for use with cartridges in sizes of 30mmcapable of loading all length cartridges on same gun only , laparoscopic liner cutter without integrated fresh knife with 360*rotation & 0-45* articulation in both direction : for use with cartridges in sizes of 45mm capable of loading all length cartridges on same gun only , laparoscopic liner cutter without integrated fresh knife with 360*rotation & 0-45* articulation in both direction : for use with cartridges in sizes of 60mm, capable of loading all length cartridges on same gun only , hand activated curved taper tip coagulating shears compatible with ultrasonic cutting and coagulation device,9cm length,16mm curved active blade with adaptive tissue technology capable of sealing blood vessels up to and including 5mm in diameter, with ergonomic symmetrical finger ring grip- focus 9 , hand activated curved taper tip coagulating shears compatible with ultrasonic cutting and coagulation device,17cm length,16mm curved active blade with adaptive tissue technology capable of sealing blood vessels upto and including 5mm in diameter, with ergonomic symmetrical finger ring grip - focus 17 , advance bipolar hand activated probe with 5mm shaft diameter and 35 cm shaft length with 5 mm wide straight jaw design with seal length of 20mm and cut length of 16mm,sealing vessel upto and including 7mm through radio frequency energy and having a temperature controlled mechanism within the jaw and having articulation of 110 degree(55 degrees on both sides) and capable of 360 degrees rotation , advance bipolar hand activated probe with 5mm shaft diameter and 45 cm shaft length with 5 mm wide straight jaw design with seal length of 20mm and cut length of 16mm,sealing vessel upto and including 7mm through radio frequency energy and having a temperature controlled mechanism within the jaw and having articulation of 110 degree(55 degrees on both sides) and capable of 360 degrees rotation , advance bipolar hand activated probe for open surgery with 13mm shaft diameter and 20 cm shaft length, 6 mm wide straight jaw design with jaw length of 38 mm ,sealing vessel upto and including 7mm through radio frequency energy , having separate seal and cut buttons, capable of 360 degrees rotation , laparoscopic shears 5mm diameter,36cm long, 15mm curved coated blade and a clamp arm with tissue pad, capable of cutting, sealing, grasping and coagulating blood vessels up to and including 5mm in diameter, 360 degrees rotation, ergonomic handle compatible with ultrasonic energy source and capable of hand and foot activation , advanced bipolar tissue sealer 25 cms, with 5mm shaft diameter, 24 mm jaw length, 21.8 mm cut length and 13.4 mm jaw aperture designed for use in open surgical procedures with curved and tapered tip and uses an advanced algorithm for intelligent and efficient energy delivery. device to have intuitive design with separate seal and cut button and 360 degree continuous shaft rotation , advanced bipolar tissue sealer 37 cms, with 5mm shaft diameter, 24 mm jaw length, 21.8 mm cut length and 13.4 mm jaw aperture designed for use in laproscopic surgical procedures with curved and tapered tip and uses an advanced algorithm for intelligent and efficient energy delivery. device to have intuitive design with separate seal and cut button and 360 degree continuous shaft rotation , advanced bipolar tissue sealer 45 cms with 5mm shaft diameter, 24 mm jaw length, 21.8 mm cut length and 13.4 mm jaw aperture designed for use in laproscopic surgical procedures with curved and tapered tip and uses an advanced algorithm for intelligent and efficient energy delivery. device to have intuitive design with separate seal and cut button and 360 degree continuous shaft rotation , laparoscopic shears 5mm diameter,36cm long, 18mm curved coated blade and a clamp arm with tissue pad, capable of cutting,sealing,grasping and coagulating blood vessels up to and including 7mm in diameter, 360 degrees rotation, advance hemostasis hand activation mode for sealing vessels upto 7mm in diameter ,ergonomic handle compatible with ultrasonic energy source, capable of hand and foot activation with an integrated hand piece and transducer. , connecting cable for ultrasonic harmonic scalpel for open energy probes compatible with focus plus shear- hp blue , connecting cable for ultrasonic harmonic scalpel for lap energy probes compatible with ace plus shear hp054 , laparoscopic shears 5mm diameter,45cm long, 15mm curved coated blade and a clamp arm with tissue pad, capable of cutting,sealing,grasping and coagulating blood vessels up to and including 7mm in diameter, 360 degrees rotation, advance hemostasis hand activation mode for sealing vessels upto 7mm in diameter, ergonomic handle compatible with ultrasonic energy source and capable of hand and foot activation , nasal haemostatic sponge pack (with airway) 10 inch , platting for maxillary swing and mandibular fixation surgeries (titanium) plates - 2 mm thickness (2x2 ) hole drill bit machine with insertion tools , platting for maxillary swing and mandibular fixation surgeries (titanium) plates - 2 mm thickness (1x2) hole drill bit machine with insertion tools , platting for maxillary swing and mandibular fixation surgeries (titanium) plates - 2 mm thickness (1x1 ) hole drill bit machine with insertion tools , platting for maxillary swing and mandibular fixation surgeries (titanium) screw- (2 mm ) diameter drill bit machine with insertion tools , platting for maxillary swing and mandibular fixation surgeries (titanium) screw- (1.5 mm ) diameter drill bit machine with insertion tools , platting for maxillary swing and mandibular fixation surgeries (titanium) screw- (2.5 mm ) diameter drill bit machine with insertion tools , platting for maxillary swing and mandibular fixation surgeries (titanium) screw- (3 mm) diameter drill bit machine with insertion tools , speech prosthesis for laryngectomy (indwelling low resistance silicon voice prosthesis varied diameter with varied length should have blue teflon valve seet for primary and secondary insertion along with inserting tools and cleaning accessories) 17fr (4 mm) , speech prosthesis for laryngectomy (indwelling low resistance silicon voice prosthesis varied diameter with varied length should have blue teflon valve seet for primary and secondary insertion along with inserting tools and cleaning accessories) 17fr (6 mm) , speech prosthesis for laryngectomy (indwelling low resistance silicon voice prosthesis varied diameter with varied length should have blue teflon valve seet for primary and secondary insertion along with inserting tools and cleaning accessories) 17fr (8 mm) , speech prosthesis for laryngectomy (indwelling low resistance silicon voice prosthesis varied diameter with varied length should have blue teflon valve seet for primary and secondary insertion along with inserting tools and cleaning accessories) 17fr (10 mm) , speech prosthesis for laryngectomy (indwelling low resistance silicon voice prosthesis varied diameter with varied length should have blue teflon valve seet for primary and secondary insertion along with inserting tools and cleaning accessories) 17fr (12.5 mm) , speech prosthesis for laryngectomy (indwelling low resistance silicon voice prosthesis varied diameter with varied length should have blue teflon valve seet for primary and secondary insertion along with inserting tools and cleaning accessories) 20fr (4 mm) , speech prosthesis for laryngectomy (indwelling low resistance silicon voice prosthesis varied diameter with varied length should have blue teflon valve seet for primary and secondary insertion along with inserting tools and cleaning accessories) 20fr (6 mm) , speech prosthesis for laryngectomy (indwelling low resistance silicon voice prosthesis varied diameter with varied length should have blue teflon valve seet for primary and secondary insertion along with inserting tools and cleaning accessories) 20fr (8 mm) , speech prosthesis for laryngectomy (indwelling low resistance silicon voice prosthesis varied diameter with varied length should have blue teflon valve seet for primary and secondary insertion along with inserting tools and cleaning accessories) 20fr (10 mm) , speech prosthesis for laryngectomy (indwelling low resistance silicon voice prosthesis varied diameter with varied length should have blue teflon valve seet for primary and secondary insertion along with inserting tools and cleaning accessories) 20fr (12.5 mm) , speech prosthesis for laryngectomy (indwelling low resistance silicon voice prosthesis varied diameter with varied length should have blue teflon valve seet for primary and secondary insertion along with inserting tools and cleaning accessories) 22.5fr (6 mm) , speech prosthesis for laryngectomy (indwelling low resistance silicon voice prosthesis varied diameter with varied length should have blue teflon valve seet for primary and secondary insertion along with inserting tools and cleaning accessories) 22.5fr (8 mm) , speech prosthesis for laryngectomy (indwelling low resistance silicon voice prosthesis varied diameter with varied length should have blue teflon valve seet for primary and secondary insertion along with inserting tools and cleaning accessories) 22.5fr (10 mm) , speech prosthesis for laryngectomy (indwelling low resistance silicon voice prosthesis varied diameter with varied length should have blue teflon valve seet for primary and secondary insertion along with inserting tools and cleaning accessories) 22.5fr (12.5 mm) , speech prosthesis for laryngectomy (indwelling low resistance silicon voice prosthesis varied diameter with varied length should have blue teflon valve seet for primary and secondary insertion along with inserting tools and cleaning accessories) 22.5fr (4 mm) , block used in thyroplasty (sialestic and gortex) 70x50 mm with 20 mm thickness , disposable needle 16g x 1 inch , curved tip & stepped cartridges face from inner to outer side 2.0,2.5 and 3.0 mm staple heights row for variable thickness tissue application , fixed anvil , different leg length staples in same cartridge , inbuilt knife ,size 45 mm tan colour code for vascular applications , curved tip & stepped cartridges face from inner to outer side 3.0,3.5 and 4.0 mm staple heights row for variable thickness tissue application , fixed anvil , different leg length staples in same cartridge , inbuilt knife ,size 45 mm purpule colour code for medium to thick tissue , varied staple height reloads/cartridges for 60 mm gia instruments with tri-staple technology, with the cutting knife blade incorporated in the reloads itself, with black varied staple height of 4, 4.5 and 5mm leg length , disposable laparoscopic clip applier preloaded with 16 clips, 5mm diameter with clip logic technology and digital display titanium clips- u shaped , synthetic oxidised re-generated cellulose double layered with peg and trilysine size 2x4cm , synthetic oxidised re-generated cellulose double layered with peg and trilysine size 5x10cm , disposable 10 mm endoscopic clip applier with facility of loading clips independent of the firing mechanism: medium/large size , disposable 10 mm endoscopic clip applier with facility of loading clips independent of the firing mechanism large size , endo liner cutter without integrated fresh knife with 360*rotation & 0-45* articulation in both direction : for use with cartridges in sizes of 30mm, capable of loading all length cartridges on same gun only , endo liner cutter without integrated fresh knife with 360*rotation & 0-45* articulation in both direction : for use with cartridges in sizes of 45mm capable of loading all length cartridges on same gun only , endo liner cutter without integrated fresh knife with 360*rotation & 0-45* articulation in both direction : for use with cartridges in sizes of 60mm, capable of loading all length cartridges on same gun only , disposable clip applier preloaded with 20 clips, superinterlock security with clip design technology medium , disposable clip applier preloaded with 20 clips, superinterlock security with clip design technology small , sterile hypodermic syringe with needle attached, 22g, single use -2 ml , sterile hypodermic syringe with needle attached, 22g, single use -5 ml , biological glue with thrombin & aprotinin 1ml , biological glue with thrombin & aprotinin 2ml , close wound drainage device under negative pressure (closed wound suction unit) , close wound drainage device under negative pressure (closed wound suction unit) , close wound drainage device under negative pressure (closed wound suction unit) , close wound drainage device under negative pressure (closed wound suction unit) , sterile oxidized regenerated cellulose hemostating agent in netform fibrillar and in thick sheath as per ip , urine collecting bag, disposable 2000 ml with uroflow meter , central neck line- double lumen (3 nobel metal coated (gold, silver, palladium)central lumen catheter, double lumen) , microcatheter selective infusion microcatheters for intra cranial aneurysm treatment with 2 tip markers , microcatheter selective infusion microcatheters for deploying intracranial device: stent deployment , microcatheter selective infusion microcatheters for flow diverter delivery with single tip markers 0.027inch , microcatheter flow dependent super-selective high flow infusion microcatheters for cerebral/spinal avms (compatible with dmso) , micro guide wire for microcatheter shapable distal end and with torque 0.014inch , bare platinum coil complex shape, soft, electrolytic detachable framing and filling , bare platinum coil complex shape, soft, mechanically detachable framing and filling , bare platinum coil helical shape, soft, electrolytic detachable , bare platinum coil helical shape, soft, mechanically detachable , aortic punch 2.5 length betwwen 6 to 7 midlength diamond edge sharp, dual cut edge for clean precise removal of aortic tissue, conical tip or round / eliptical tip for easy insertation by straight or button hole tech, should have long and short handle confirguaration, sterile packing , aortic punch 3 length betwwen 6 to 7 midlength diamond edge sharp, dual cut edge for clean precise removal of aortic tissue, conical tip or round / eliptical tip for easy insertation by straight or button hole tech, should have long and short handle confirguaration, sterile packing , aortic punch 3.5 length betwwen 6 to 7 midlength diamond edge sharp, dual cut edge for clean precise removal of aortic tissue, conical tip or round / eliptical tip for easy insertation by straight or button hole tech, should have long and short handle confirguaration, sterile packing , aortic punch 4 length betwwen 6 to 7 midlength diamond edge sharp, dual cut edge for clean precise removal of aortic tissue, conical tip or round / eliptical tip for easy insertation by straight or button hole tech, should have long and short handle confirguaration, sterile packing , aortic punch 4.5 length betwwen 6 to 7 midlength diamond edge sharp, dual cut edge for clean precise removal of aortic tissue, conical tip or round / eliptical tip for easy insertation by straight or button hole tech, should have long and short handle confirguaration, sterile packing , aortic punch 5 length betwwen 6 to 7 midlength diamond edge sharp, dual cut edge for clean precise removal of aortic tissue, conical tip or round / eliptical tip for easy insertation by straight or button hole tech, should have long and short handle confirguaration, sterile packing , aortic punch 5.5 length betwwen 6 to 7 midlength diamond edge sharp, dual cut edge for clean precise removal of aortic tissue, conical tip or round / eliptical tip for easy insertation by straight or button hole tech, should have long and short handle confirguaration, sterile packing , aortic punch 3.6 length betwwen 6 to 7 midlength diamond edge sharp, dual cut edge for clean precise removal of aortic tissue, conical tip or round / eliptical tip for easy insertation by straight or button hole tech, should have long and short handle confirguaration, sterile packing , folleys catheter fixation divice foley catheter holder universal size should have leg band and is disposable single patiemnt use device should have catheter grip of 18 to 24 fr catheter and made of crobelt or any other. , tur set tur irrigation set disposable urology instrument urology equipment endosurgery, mfg from clinical grade non toxic medical transparent pvc sheet, y shaped connector with pointed spike to easy pierce facilities alternative change solution, thumb operated clamp smooth chnage of bottle, proximal end fitted with flexible latest tubing for easy connection to endoscope, eto steril individual pack. should have minium lenght of 260 cm or more. , laproscopic port with trocar 5mm optically guided bladeless trocar 5mm with bilateral tissue separators, optical tip to eliminate blind entry, clear ribbed cannula to enhance abdominal wall retention, recessed stopcock valve, funnel shaped housing, duckbill secondary seal, integrated universal seal that eliminates the use of reducer, 150mm length. , programmable automatic bipsy gun with compitible co-axial needle should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. should have three programmable firing mode-automatic mode, delay mode and zero throw mode. should have two firing btton on surface of the gun, size 12g, 14g, 16g, 18g, 20g with length 11cm, 15cm, 20cm. should come with compitible coaxial packed with biopsy gun. usfda approved. , programmable automatic bipsy gun with compitible co-axial needle should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. should have three programmable firing mode-automatic mode, delay mode and zero throw mode. should have two firing btton on surface of the gun, size 12g, 14g, 16g, 18g, 20g with length 11cm, 15cm, 20cm. should come with compitible coaxial packed with biopsy gun. usfda approved. , programmable automatic bipsy gun with compitible co-axial needle should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. should have three programmable firing mode-automatic mode, delay mode and zero throw mode. should have two firing btton on surface of the gun, size 12g, 14g, 16g, 18g, 20g with length 11cm, 15cm, 20cm. should come with compitible coaxial packed with biopsy gun. usfda approved. , programmable automatic bipsy gun with compitible co-axial needle should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. should have three programmable firing mode-automatic mode, delay mode and zero throw mode. should have two firing btton on surface of the gun, size 12g, 14g, 16g, 18g, 20g with length 11cm, 15cm, 20cm. should come with compitible coaxial packed with biopsy gun. usfda approved. , programmable automatic bipsy gun with compitible co-axial needle should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. should have three programmable firing mode-automatic mode, delay mode and zero throw mode. should have two firing btton on surface of the gun, size 12g, 14g, 16g, 18g, 20g with length 11cm, 15cm, 20cm. should come with compitible coaxial packed with biopsy gun. usfda approved. , programmable automatic bipsy gun with compitible co-axial needle should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. should have three programmable firing mode-automatic mode, delay mode and zero throw mode. should have two firing btton on surface of the gun, size 12g, 14g, 16g, 18g, 20g with length 11cm, 15cm, 20cm. should come with compitible coaxial packed with biopsy gun. usfda approved. , programmable automatic bipsy gun with compitible co-axial needle should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. should have three programmable firing mode-automatic mode, delay mode and zero throw mode. should have two firing btton on surface of the gun, size 12g, 14g, 16g, 18g, 20g with length 11cm, 15cm, 20cm. should come with compitible coaxial packed with biopsy gun. usfda approved. , programmable automatic bipsy gun with compitible co-axial needle should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. should have three programmable firing mode-automatic mode, delay mode and zero throw mode. should have two firing btton on surface of the gun, size 12g, 14g, 16g, 18g, 20g with length 11cm, 15cm, 20cm. should come with compitible coaxial packed with biopsy gun. usfda approved. , programmable automatic bipsy gun with compitible co-axial needle should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. should have three programmable firing mode-automatic mode, delay mode and zero throw mode. should have two firing btton on surface of the gun, size 12g, 14g, 16g, 18g, 20g with length 11cm, 15cm, 20cm. should come with compitible coaxial packed with biopsy gun. usfda approved. , programmable automatic bipsy gun with compitible co-axial needle should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. should have three programmable firing mode-automatic mode, delay mode and zero throw mode. should have two firing btton on surface of the gun, size 12g, 14g, 16g, 18g, 20g with length 11cm, 15cm, 20cm. should come with compitible coaxial packed with biopsy gun. usfda approved. , programmable automatic bipsy gun with compitible co-axial needle should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. should have three programmable firing mode-automatic mode, delay mode and zero throw mode. should have two firing btton on surface of the gun, size 12g, 14g, 16g, 18g, 20g with length 11cm, 15cm, 20cm. should come with compitible coaxial packed with biopsy gun. usfda approved. , programmable automatic bipsy gun with compitible co-axial needle should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. should have three programmable firing mode-automatic mode, delay mode and zero throw mode. should have two firing btton on surface of the gun, size 12g, 14g, 16g, 18g, 20g with length 11cm, 15cm, 20cm. should come with compitible coaxial packed with biopsy gun. usfda approved. , programmable automatic bipsy gun with compitible co-axial needle should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. should have three programmable firing mode-automatic mode, delay mode and zero throw mode. should have two firing btton on surface of the gun, size 12g, 14g, 16g, 18g, 20g with length 11cm, 15cm, 20cm. should come with compitible coaxial packed with biopsy gun. usfda approved. , programmable automatic bipsy gun with compitible co-axial needle should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. should have three programmable firing mode-automatic mode, delay mode and zero throw mode. should have two firing btton on surface of the gun, size 12g, 14g, 16g, 18g, 20g with length 11cm, 15cm, 20cm. should come with compitible coaxial packed with biopsy gun. usfda approved. , programmable automatic bipsy gun with compitible co-axial needle should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. should have three programmable firing mode-automatic mode, delay mode and zero throw mode. should have two firing btton on surface of the gun, size 12g, 14g, 16g, 18g, 20g with length 11cm, 15cm, 20cm. should come with compitible coaxial packed with biopsy gun. usfda approved. , patient pre operative skin prepration solution 26 ml in one step sterile applicator container for single use with 2% chlorohexdine gluconate (chg) and 70% ipa with orange tint colour or easy visulization, us fda approved , rem and non-rem single use, corded patient return electrodes conductive adhesive hydrogel with usfda. , chlorhexidine impregnated paraffin gauze 30x10 cm , chlorhexidine impregnated paraffin 15 cm x 1 roll , surgical gloves 6.5 non latex surgical gloves synthetic polyisoprene powder free overall length 283mm with puncture indicator technology usfda approved , surgical gloves 7 non latex surgical gloves synthetic polyisoprene powder free overall length 283mm with puncture indicator technology usfda approved , surgical gloves 7.5 non latex surgical gloves synthetic polyisoprene powder free overall length 283mm with puncture indicator technology usfda approved , ionic silver dressings with broad spectrum antimicrobial, bactericidal, biofilm destruction & reformation efficacies recommended for low to high exuding wounds 5 cms x 5 cms , ionic silver dressings with broad spectrum antimicrobial, bactericidal, biofilm destruction & reformation efficacies recommended for low to high exuding wounds 10 cms x 10 cms , self adherent moist wound dressing made up of triple hydrocolloid matrix,elastomeric polymer for pressure ulcers/bed sores 10 cms x 10 cms , stich bonded hydrofiber burns dresssings with 1.2% impregnated ionic silver with sustained and on demand broad spectrum antimicrobial & bactricidal activity with high exudate management capability with a wear time of 21 days & locking in edudates in gel form 23 x 100 cms , double wall resuscitator with peep valve in adult it should be fully autoclavable double wall with hand strap it should be supplied with autoclavable reservoir bag it should have a single shutter valve system made of silicone rubber it should have easy attachment of peep valve for adult bag volume: mark iv (1300 ml) weight: adult (415 g) it should be us-fda, ce & iso certified , double wall resuscitator with peep valve in paediatrics it should be fully autoclavable double wall with hand strap it should be supplied with autoclavable reservoir bag it should have a single shutter valve system made of silicone rubber it should have easy attachment of peep valve for peadiatric it should have provision to attach manometer for paediatrics ambu bag bag volume: mark iv baby (300 ml) weight: baby (190 g) it should be us-fda, ce & iso certified , single patient use sebs resuscitator (spur ii with peep valve in adult) • it should be single use resuscitator made to sebs material not pvc. • it should have unique single-shutter valve system for reliable functionality & swivel between valve and mask permits 360° positioning in relation to the patient • it should have thin-walled compression bag with hand strip. • resuscitator volume: adult (1475 ml) • (including reservoir and mask) • it should be ce/iso, us fda certified. , single patient use sebs resuscitator (spur ii with peep valve in paed) • it should be single use resuscitator made to sebs material not pvc. • it should have unique single-shutter valve system for reliable functionality & swivel between valve and mask permits 360° positioning in relation to the patient • it should have thin-walled compression bag with hand strip.it should have provision to attach manometer for paediatrics ambu bag. • resuscitator volume: pediatric (635 ml) • (including reservoir and mask) • it should be ce/iso, us fda certified. , single patient use sebs resuscitator (spur ii with peep valve in neonatal) • it should be single use resuscitator made to sebs material not pvc. • it should have unique single-shutter valve system for reliable functionality & swivel between valve and mask permits 360° positioning in relation to the patient • it should have thin-walled compression bag with hand strip. • resuscitator volume: neonate(220ml) • (including reservoir and mask) • it should be ce/iso, us fda certified. , pre-formed sga with gastric access & intubation it should be latex free preformed laryngeal mask having gastric access channel and should be used as a conduit for direct endotracheal intubation with any brand ett • it should built-in, anatomically correct curve and cuff & tube moulded as a single unit. • ultra-thin pilot balloon with tactile indication of degree of inflation. • universal 15mm connector (iso). • it should be ce/iso, us fda certified , pre-formed sga with gastric access & intubation it should be latex free preformed laryngeal mask having gastric access channel and should be used as a conduit for direct endotracheal intubation with any brand ett • it should built-in, anatomically correct curve and cuff & tube moulded as a single unit. • ultra-thin pilot balloon with tactile indication of degree of inflation. • universal 15mm connector (iso). • it should be ce/iso, us fda certified , pre-formed sga with gastric access & intubation it should be latex free preformed laryngeal mask having gastric access channel and should be used as a conduit for direct endotracheal intubation with any brand ett • it should built-in, anatomically correct curve and cuff & tube moulded as a single unit. • ultra-thin pilot balloon with tactile indication of degree of inflation. • universal 15mm connector (iso). • it should be ce/iso, us fda certified , pre-formed sga with gastric access & intubation it should be latex free preformed laryngeal mask having gastric access channel and should be used as a conduit for direct endotracheal intubation with any brand ett • it should built-in, anatomically correct curve and cuff & tube moulded as a single unit. • ultra-thin pilot balloon with tactile indication of degree of inflation. • universal 15mm connector (iso). • it should be ce/iso, us fda certified , pre-formed sga with gastric access & intubation it should be latex free preformed laryngeal mask having gastric access channel and should be used as a conduit for direct endotracheal intubation with any brand ett • it should built-in, anatomically correct curve and cuff & tube moulded as a single unit. • ultra-thin pilot balloon with tactile indication of degree of inflation. • universal 15mm connector (iso). • it should be ce/iso, us fda certified , pre-formed sga with gastric access & intubation it should be latex free preformed laryngeal mask having gastric access channel and should be used as a conduit for direct endotracheal intubation with any brand ett • it should built-in, anatomically correct curve and cuff & tube moulded as a single unit. • ultra-thin pilot balloon with tactile indication of degree of inflation. • universal 15mm connector (iso). • it should be ce/iso, us fda certified , pre-formed sga with gastric access & intubation it should be latex free preformed laryngeal mask having gastric access channel and should be used as a conduit for direct endotracheal intubation with any brand ett • it should built-in, anatomically correct curve and cuff & tube moulded as a single unit. • ultra-thin pilot balloon with tactile indication of degree of inflation. • universal 15mm connector (iso). • it should be ce/iso, us fda certified , pre-formed sga with gastric access & intubation it should be latex free preformed laryngeal mask having gastric access channel and should be used as a conduit for direct endotracheal intubation with any brand ett • it should built-in, anatomically correct curve and cuff & tube moulded as a single unit. • ultra-thin pilot balloon with tactile indication of degree of inflation. • universal 15mm connector (iso). • it should be ce/iso, us fda certified , silicone pre-formed sga • it should be and autoclavable up to 40 times • it should have reinforced tip at cuff and cuff & tube moulded as a single unit. • atraumatic insertion and removal. • it should be ce/iso, us fda certified , silicone pre-formed sga • it should be and autoclavable up to 40 times • it should have reinforced tip at cuff and cuff & tube moulded as a single unit. • atraumatic insertion and removal. • it should be ce/iso, us fda certified , silicone pre-formed sga total size 8 • it should be and autoclavable up to 40 times • it should have reinforced tip at cuff and cuff & tube moulded as a single unit. • atraumatic insertion and removal. • it should be ce/iso, us fda certified , silicone pre-formed sga • it should be and autoclavable up to 40 times • it should have reinforced tip at cuff and cuff & tube moulded as a single unit. • atraumatic insertion and removal. • it should be ce/iso, us fda certified , silicone pre-formed sga • it should be and autoclavable up to 40 times • it should have reinforced tip at cuff and cuff & tube moulded as a single unit. • atraumatic insertion and removal. • it should be ce/iso, us fda certified , silicone pre-formed sga • it should be and autoclavable up to 40 times • it should have reinforced tip at cuff and cuff & tube moulded as a single unit. • atraumatic insertion and removal. • it should be ce/iso, us fda certified , silicone pre-formed sga • it should be and autoclavable up to 40 times • it should have reinforced tip at cuff and cuff & tube moulded as a single unit. • atraumatic insertion and removal. • it should be ce/iso, us fda certified , silicone pre-formed sga • it should be and autoclavable up to 40 times • it should have reinforced tip at cuff and cuff & tube moulded as a single unit. • atraumatic insertion and removal. • it should be ce/iso, us fda certified , cervical collar with 12 sizes settings • it should be latex free adjustable collar with 12 size setting in paediatric collar • it should have standard sizing line for easy and accurate sizing • it should be ce/iso, us fda certified , cervical collar with 16 sizes settings • it should be latex free adjustable collar with 16 size setting in adult collar • it should have standard sizing line for easy and accurate sizing • it should be ce/iso, us fda certified , offset connector cardio sensor electrodes • it should have high conductive wet gel to ensure reliable traces. • it should be design with offset connector to prevent artefacts from disrupting the readouts • it should have high quality ag/agcl sensor to ensure excellent trace quality • it should have size not more than 72 x 68 mm , offset connector cardio sensor electrodes • it should have high conductive wet gel to ensure reliable traces. • it should be design with offset connector to prevent artefacts from disrupting the readouts • it should have high quality ag/agcl sensor to ensure excellent trace quality • it should have size not more than 72 x 68 mm , offset connector cardio sensor electrodes • it should have high conductive wet gel to ensure reliable traces. • it should be design with offset connector to prevent artefacts from disrupting the readouts • it should have high quality ag/agcl sensor to ensure excellent trace quality • it should have size not more than 72 x 68 mm , anatomical face mask with thumb rest silicone •thumb rest for a tight, easy seal, made up of silicone , anatomical face mask with thumb rest silicone •thumb rest for a tight, easy seal, made up of silicone • can be autoclaved repeatedly at 134°c , anatomical face mask with thumb rest silicone •thumb rest for a tight, easy seal, made up of silicone • can be autoclaved repeatedly at 134°c , anatomical face mask with thumb rest silicone •thumb rest for a tight, easy seal, made up of silicone • can be autoclaved repeatedly at 134°c , anatomical face mask with thumb rest silicone •thumb rest for a tight, easy seal, made up of silicone • can be autoclaved repeatedly at 134°c , anatomical face mask with thumb rest silicone •thumb rest for a tight, easy seal, made up of silicone • can be autoclaved repeatedly at 134°c , anatomical face mask with thumb rest silicone •thumb rest for a tight, easy seal, made up of silicone • can be autoclaved repeatedly at 134°c , disposable sga anatomical curve • it should have special curve that carefully replicates natural human anatomy • it moulded directly into the tube • should have a d-shaped airway tube to give a firm and ergonomically grip during insertion , disposable sga anatomical curve • it should have special curve that carefully replicates natural human anatomy • it moulded directly into the tube • should have a d-shaped airway tube to give a firm and ergonomically grip during insertion , disposable sga anatomical curve • it should have special curve that carefully replicates natural human anatomy • it moulded directly into the tube • should have a d-shaped airway tube to give a firm and ergonomically grip during insertion , disposable sga anatomical curve • it should have special curve that carefully replicates natural human anatomy • it moulded directly into the tube • should have a d-shaped airway tube to give a firm and ergonomically grip during insertion , disposable sga anatomical curve • it should have special curve that carefully replicates natural human anatomy • it moulded directly into the tube • should have a d-shaped airway tube to give a firm and ergonomically grip during insertion , disposable sga anatomical curve • it should have special curve that carefully replicates natural human anatomy • it moulded directly into the tube • should have a d-shaped airway tube to give a firm and ergonomically grip during insertion , disposable sga anatomical curve • it should have special curve that carefully replicates natural human anatomy • it moulded directly into the tube • should have a d-shaped airway tube to give a firm and ergonomically grip during insertion , disposable sga anatomical curve • it should have special curve that carefully replicates natural human anatomy • it moulded directly into the tube • should have a d-shaped airway tube to give a firm and ergonomically grip during insertion , rhinolaryngo single patient use slim scope insertion tube diameter : 3.0mm. working length: 300 mm bending range : 130 degree up & 130 degree down field of view : 85 degree or more direction of view : 0 degree (forward view) depth of field : 6-50 mm or better complete system should be us-fda and european ce certified , rhinolaryngo single patient use invtervention scope channel width : 2.2mm insertion tube diameter : 5.0 mm. working length : 350 mm bending range :130 degree up & 130 degree down field of view : 85 degree or more direction of view : 0 degree (forward view) depth of field : 6-50 mm or better complete system should be us-fda and european ce certified , ultrasorbs ap disposable drypads, dry pad for moisture management, 58.4x90cm, with breathable layer, super absorbent core, aqua shield film and air permeable back sheet, absorbency of 1800-2300gm, usfda/ce/bis compliant, iso13485 compliant , elastic head strap cannulas pediatric elastic head strap cannulas pediatric must be soft siliconised, transparent vinyl; adjustable elastic band for comfortable, snug fit below the ears; complete kit with 7-ft oxygen supply tubing. manufacturer must be us-fda registered & certified with en/eu iso 13485 & applicable 510k & ce certification. , over-the-ear nasal cannula over-the-ear nasal cannula with star lumen, 50 tubing, must be flexible contoured lip tab provides a high level of stability and patient comfort. over-the-ear design for a comfortable and secure fit, crush- and kink-resistant tubing. manufacturer must be us-fda registered & certified with en/eu iso 13485 & applicable 510k & ce certification. , pediatric nasal cannula pediatric nasal cannula softech with universal oxygen connector, 7 star-lumen tubing lightweight, flexible nasal cannula with standard over-the-ear designed that optimizes fit and stability, soft nasal prongs help maximize patient comfort. individually packaged for convenience and sterility. manufacturer must be us-fda registered & certified with en/eu iso 13485 & applicable 510k & ce certification. , infant nasal cannula infant nasal cannula softech with universal oxygen connector, 7 star-lumen tubing lightweight, flexible nasal cannula with standard over-the-ear designed that optimizes fit and stability, soft nasal prongs to help maximize patient comfort. individually packaged for convenience and sterility. manufacturer must be us-fda registered & certified with en/eu iso 13485 & applicable 510k & ce certification. , volumetric incentive spirometer (adult) volumetric incentive spirometer (adult) 4000 ml with handle. volume measurement must be compact comfortable designed to accommodate large inspired volumes. must have good-better-best flow window & advanced, low work-of-breathing design. particulate filter screen in device housing must help to reduce risk of foreign matter passing to patients. expandable and collapsible tube must help patients find comfortable position for treatments and can be removed when storing the device. ergonomic swiveled mouthpiece allows to patients create tight seal to enable more accurate measurement. flow indicator with smiley face provides visual target for desired inhalation and bright green flow indicator make it easy for patients to see results. manufacturer must be us-fda registered & certified with en/eu iso 13485 & applicable 510k & ce certification. , volumetric incentive spirometer (pediatric) volumetric incentive spirometer (pediatric) 2500 ml with handle. volume measurement must be compact comfortable designed to accommodate large inspired volumes. must have good-better-best flow window & advanced, low work-of-breathing design. particulate filter screen in device housing must help to reduce risk of foreign matter passing to patients. expandable and collapsible tube must help patients find comfortable position for treatments and can be removed when storing the device. ergonomic swiveled mouthpiece allows to patients create tight seal to enable more accurate measurement. flow indicator with smiley face provides visual target for desired inhalation and bright green flow indicator make it easy for patients to see results. manufacturer must be us-fda registered & certified with en/eu iso 13485 & applicable 510k & ce certification. , inspiratory exerciser with 3 color-coded balls, 3 chambers inspiratory exerciser with 3 color-coded balls, 3 chambers & wide flow rate range from 600 to 1200 cc/sec, with minimum flow imprinted on each chamber. must be compact design and made of break-resistant plastic. manufacturer must be us-fda registered & certified with en/eu iso 13485 & applicable 510k & ce certification. , adult mask for tracheostomy adult mask for tracheostomy and laryngectomy aerosol therapy tubing connector must swivels 360° for ease of positioning; 22 mm od connector accepts 22 mm, corrugated tubing and nebulizer tees. manufacturer must be us-fda registered & certified with en/eu iso 13485 & applicable 510k & ce certification. , pardiatric mask for tracheostomy pediatric mask for tracheostomy and laryngectomy aerosol therapy tubing connector must swivels 360° for ease of positioning; 22 mm od connector accepts 22 mm, corrugated tubing and nebulizer tees. manufacturer must be us-fda registered & certified with en/eu iso 13485 & applicable 510k & ce certification. , elongated aerosol mask adult elongated aerosol mask adult with under-the-chin design for excellent fit on wide range of face sizes must be clear, soft vinyl for patient comfort; adjustable nose clip assures comfortable fit; specifically designed for aerosol therapy; must be with supplied with 6 ft. corr a flex corrugated tubing, featuring cuttable sections every 6 in. manufacturer must be us-fda registered & certified with en/eu iso 13485 & applicable 510k & ce certification. , elongated aerosol mask pediatric elongated aerosol mask pediatric with under-the-chin design for excellent fit on wide range of face sizes must be clear, soft vinyl for patient comfort; adjustable nose clip assures comfortable fit; specifically designed for aerosol therapy; must be with supplied with 6 ft. corr a flex corrugated tubing, featuring cuttable sections every 6 in. manufacturer must be us-fda registered & certified with en/eu iso 13485 & applicable 510k & ce certification. , elongated three-in-one adult mask elongated three-in-one adult mask must be able to use as a medium-concentration, high-concentration or nonrebreathing mask which includes mask with flapper valve, nonrebreathing bag assembly; adjustable nose clip assures comfortable fit; with 7 ft. star lumen oxygen supply tubing; 750 ml reservoir bag. manufacturer must be us-fda registered & certified with en/eu iso 13485 & applicable 510k & ce certification. , adult conventional single water trap adult conventional single water trap (non-heated) ventilator circuits are available in a variety of different configurations and styles.to incorporate standard connectors for use with a variety of ventilators, ported wyes allow pressure sensing and temperature monitoring and include tethered caps, all adult conventional circuits with 72 in. long, standard ventilator circuit with straight connector inspiratory limb water trap (for use with hmes only). manufacturer must be us-fda registered & certified with en/eu iso 13485 & applicable 510k & ce certification. , adult ventilator circuit single limb portable adult ventilator circuit with universal single limb. must be complete kit with main circuit hose, exhalation valve manifold, aerosol hose, patient elbow connector, proximal airway pressure line, exhalation valve line, and humidifier limb. manufacturer must be us-fda registered & certified with en/eu iso 13485 & applicable 510k & ce certification. , adult ventilator circuit single water trap adult conventional single water trap (non-heated) ventilator circuits are available in a variety of different configurations and styles.to incorporate standard connectors for use with a variety of ventilators, ported wyes allow pressure sensing and temperature monitoring and include tethered caps, all adult conventional circuits with 72 in. long, standard ventilator circuit with straight connector inspiratory limb water trap (for use with hmes only). manufacturer must be us-fda registered & certified with en/eu iso 13485 & applicable 510k & ce certification. , adult conventional dual limb water trap adult conventional dual limb water trap (non-heated) ventilator circuits are available in a variety of different configurations and styles.to incorporate standard connectors for use with a variety of ventilators, ported wyes allow pressure sensing and temperature monitoring and include tethered caps, all adult conventional circuits with 72 in. long, standard ventilator circuit with straight connector dual limb inspiratory & expiratory water trap 22mm tubing, (for use with hmes only). manufacturer must be us-fda registered & certified with en/eu iso 13485 & applicable 510k & ce certification. , infant prong cpap cannula infant prong cpap cannula nasal size 0 with designed to reduce trauma associated with delivery of infant nasal cpap. must be soft siliconised, anatomically curved prongs to enhance fit. luer fitting on expiratory connector to allow proximal airway pressure monitoring. each set to include, soft siliconised cannula; inspiratory & expiratory elbow connector; knit cap; two 6 in. hook and loop fastener sections; two 10 to 7.5 mm adaptors. manufacturer must be us-fda registered & certified with en/eu iso 13485 & applicable 510k & ce certification. , fhme heat and moisture exchangers with bacteria viral filters bacterial filtration efficiency> 99.99 % and viral filtration efficiency > 99.9999% . filter membrane should be of a hydrophobic non-woven polypropylene material. should be tailored to meet the specific needs of both anaesthesia and intensive care. , tracheostomy hme: 1 heat and moisture exchangers for spontaneously breathing tracheotomy patients. 2 should have in built oxygen port. 3 should be compact & light wt. 4 should be suitable for ambulatory patients, sampling and suctioning can be done without removing it. 5 the system should have kink resisting oxygen tubing , double lumen endobronchial tube left: size-28fr low pressure tracheal and bronchial cuffs to minimise risk of mucosal damage. color coded bronchial cuff, bronchial proximal lumen and bronchial pilot balloon assists in location of tube and tip when verification is confirmed by fiberoptic bronchoscope. x-ray opaque markers at distal tip above bronchial cuff and at tracheal opening for verification of tube position. , double lumen endobronchial tube left: size-32fr low pressure tracheal and bronchial cuffs to minimise risk of mucosal damage. color coded bronchial cuff, bronchial proximal lumen and bronchial pilot balloon assists in location of tube and tip when verification is confirmed by fiberoptic bronchoscope. x-ray opaque markers at distal tip above bronchial cuff and at tracheal opening for verification of tube position. , double lumen endobronchial tube left: size-35fr low pressure tracheal and bronchial cuffs to minimise risk of mucosal damage. color coded bronchial cuff, bronchial proximal lumen and bronchial pilot balloon assists in location of tube and tip when verification is confirmed by fiberoptic bronchoscope. x-ray opaque markers at distal tip above bronchial cuff and at tracheal opening for verification of tube position. , double lumen endobronchial tube left: size-37fr low pressure tracheal and bronchial cuffs to minimise risk of mucosal damage. color coded bronchial cuff, bronchial proximal lumen and bronchial pilot balloon assists in location of tube and tip when verification is confirmed by fiberoptic bronchoscope. x-ray opaque markers at distal tip above bronchial cuff and at tracheal opening for verification of tube position. , double lumen endobronchial tube left: size-39fr low pressure tracheal and bronchial cuffs to minimise risk of mucosal damage. color coded bronchial cuff, bronchial proximal lumen and bronchial pilot balloon assists in location of tube and tip when verification is confirmed by fiberoptic bronchoscope. x-ray opaque markers at distal tip above bronchial cuff and at tracheal opening for verification of tube position. , double lumen endobronchial tube left: size-41fr low pressure tracheal and bronchial cuffs to minimise risk of mucosal damage. color coded bronchial cuff, bronchial proximal lumen and bronchial pilot balloon assists in location of tube and tip when verification is confirmed by fiberoptic bronchoscope. x-ray opaque markers at distal tip above bronchial cuff and at tracheal opening for verification of tube position. , double lumen endobronchial tube right: size-35fr low pressure tracheal and bronchial cuffs to minimize risk of mucosal damage. color coded bronchial cuff, bronchial proximal lumen and bronchial pilot balloon assists in location of tube and tip when verification is confirmed by fibreoptic bronchoscope. x-ray opaque markers at distal tip above bronchial cuff and at tracheal opening for verification of tube position. , double lumen endobronchial tube right: size-37fr low pressure tracheal and bronchial cuffs to minimize risk of mucosal damage. color coded bronchial cuff, bronchial proximal lumen and bronchial pilot balloon assists in location of tube and tip when verification is confirmed by fibreoptic bronchoscope. x-ray opaque markers at distal tip above bronchial cuff and at tracheal opening for verification of tube position. , double lumen endobronchial tube right: size-39fr low pressure tracheal and bronchial cuffs to minimize risk of mucosal damage. color coded bronchial cuff, bronchial proximal lumen and bronchial pilot balloon assists in location of tube and tip when verification is confirmed by fibreoptic bronchoscope. x-ray opaque markers at distal tip above bronchial cuff and at tracheal opening for verification of tube position. , sub-glottic tube taper guard evac: sizes 6mm the tube should have an additional lumen integrated into the wall of the tube to allow suctioning of subglottic space. should have cuff in taper size to prevent micro aspiration should have low volume/low pressure cuff. , sub-glottic tube taper guard evac: sizes 6.5mm the tube should have an additional lumen integrated into the wall of the tube to allow suctioning of subglottic space. should have cuff in taper size to prevent micro aspiration should have low volume/low pressure cuff. , sub-glottic tube taper guard evac: sizes 7mm the tube should have an additional lumen integrated into the wall of the tube to allow suctioning of subglottic space. should have cuff in taper size to prevent micro aspiration should have low volume/low pressure cuff. , sub-glottic tube taper guard evac: sizes 7.5mm the tube should have an additional lumen integrated into the wall of the tube to allow suctioning of subglottic space. should have cuff in taper size to prevent micro aspiration should have low volume/low pressure cuff. , sub-glottic tube taper guard evac: sizes 8mm the tube should have an additional lumen integrated into the wall of the tube to allow suctioning of subglottic space. should have cuff in taper size to prevent micro aspiration should have low volume/low pressure cuff. , sub-glottic tube taper guard evac: sizes 8.5mm the tube should have an additional lumen integrated into the wall of the tube to allow suctioning of subglottic space. should have cuff in taper size to prevent micro aspiration should have low volume/low pressure cuff. , sub-glottic tube taper guard evac: sizes 9mm the tube should have an additional lumen integrated into the wall of the tube to allow suctioning of subglottic space. should have cuff in taper size to prevent micro aspiration should have low volume/low pressure cuff. , inflation device inflation device in 30atm & 20ml with clear polycarbonate barrel for easy visualisation of bubbles, luminescent dial, airless rotator, lock release handle for easy one-handed control and primelok for easy preparation.usfda approvedq , manifold manifolds in 2, 3, 5 port with configuration of left-right orientation, on-off handle, full-half body, 200 psi-500 psi rating and wide port spacing. should have clear polycarbonate body to provide durability and visibility, airless rotator and large bore inner lumen throughout including rotator.usfda approved , high pressure tube high pressure tubing in 25cm with braided, flexible tubing of polyurethane rated 1200 psi. usfda approved , high pressure tube high pressure tubing in 51cm with braided, flexible tubing of polyurethane rated 1200 psi. usfda approved , high pressure tube high pressure tubing in 76,cm with braided, flexible tubing of polyurethane rated 1200 psi. usfda approved , high pressure tube high pressure tubing in 122,cm with braided, flexible tubing of polyurethane rated 1200 psi. usfda approved , high pressure tube high pressure tubing in 183cm with braided, flexible tubing of polyurethane rated 1200 psi. usfda approved , torque device torque device for .014 to .038 standard and hydrophilic guide wires with squeeze-load-release mechanism.usfda approved , radial band radial hemostatis band in 24 cm . curved backer plat with large area & clear unobstructed site visibility, convinient tubing clip with two check valve options and device stickers. should be available with standard luer and specialized connection syringe. us fda approved , radial band radial hemostatis band in 29 cm. curved backer plat with large area & clear unobstructed site visibility, convinient tubing clip with two check valve options and device stickers. should be available with standard luer and specialized connection syringe. us fda approved , angiography needle angiography needle in 18g, length of 2-9cm. should be available in echo enhanced & smooth finish, ergonomic hub with bevel orientation point, silicone coated stainless steel to reduce needle drag and superior sharpness to facilitate entry into tissue and vessel wall. usfda approved , angiography needle angiography needle in 19g, length of 2-9cm. should be available in echo enhanced & smooth finish, ergonomic hub with bevel orientation point, silicone coated stainless steel to reduce needle drag and superior sharpness to facilitate entry into tissue and vessel wall. usfda approved , angiography needle angiography needle in 20g, length of 2-9cm. should be available in echo enhanced & smooth finish, ergonomic hub with bevel orientation point, silicone coated stainless steel to reduce needle drag and superior sharpness to facilitate entry into tissue and vessel wall. usfda approved , angiography needle angiography needle in 21g, length of 2-9cm. should be available in echo enhanced & smooth finish, ergonomic hub with bevel orientation point, silicone coated stainless steel to reduce needle drag and superior sharpness to facilitate entry into tissue and vessel wall. usfda approved , angiography wire ptfe guidewire in .035, .038, in regular length. should have 3mm j-tip, straight tip, pre-coating for smooth surface with less friction, finger straight-able with precise j-tip memory and packed in flush hoop with j straightener. should have option of fixed core, movable core, heparin coating, 1.5mm j-tip. usfda approved , angiography wire long length ptfe guidewire in .035, .038, with exchange length. should have 3mm j-tip, straight tip, pre-coating for smooth surface with less friction, finger straight-able with precise j-tip memory and packed in flush hoop with j straightener. should have option of fixed core, movable core, heparin coating, 1.5mm j-tip. usfda approved , amplatz wire ptfe amplatz type wire in .035 and .038, length of 75cm, 145cm, 180cm. should be available in multiple flexible tip length of 1.0cm, 3.5cm, 4.0cm, 6cm, 7cm and j 3.0mm. usfda approved. usfda approved , hydrophilic wire hydrophilic guidewire of .018, .025, .035, .038 in 80cm, 150cm with straight, angled tip. should come in stiff & standard configuration, nitinol core polyurethane jacket hydrophilic coated guide wires with radiopaque jacket for enhanced visibility, hydrated gel coating and true 1:1 torque. usfda approved , hydrophilic wire long length hydrophilic guidewire of .018, .025, .035, .038 in 180cm, 220cm, 260cm length with straight, angled tip. should come in stiff & standard configuration, nitinol core polyurethane jacket hydrophilic coated guide wires with radiopaque jacket for enhanced visibility, hydrated gel coating and true 1:1 torque. usfda approved , hydrophillic braided sheath hydrophilic braided sheath introducer in 4f to 7f, length of 7, 11, 16, 23cm with the option of .018, .021, .025 plastic jacketed and spring coil guidewire. should have ultra-thin wall and flat wire braiding technology to provide support and low profile.usfda approved , femoral sheath with needle femoral sheath in 5f to 8f, length of 11-23cm with puncher needle of 18g and guidewire of .035, .038. should have rotating suture ring, snap-fit dilator to prevent slipping during insertion and holster pack. should be available in polypropylene. usfda approved , angiography catheter diagnostic catheter in 4f-6f, length of 70-110cm & 125cm , should come in various shapes & curve length including jl & jr (1.5, 2, 2.5, 3, 3.5, 4, 4.5, 5, 6 cm), al, ar, tig, mp, im, sones, pigtail (straight, angle, radial). should have flat wire braiding, nylon material, thin wall design for higher flow rates, radio-opaque tip, strain relief and winged polycarbonate hub. should be available in various configurations- braided, non braided, short tip, bumper tip, sideholes as applicable. usfda approved , angiography radial catheters diagnostic radial catheter with radial ultimate curve in 4-6f. lenght of 100cm, 110cm, 125cm. should have four type of radial ultimate curves. should have flat wire braiding, nylon material, thin wall design for higher flow rates, radio-opaque tip, strain relief and winged polycarbonate hub. us fda approved , one loop & triple loop snare snare kit(2-35mm diameter, 90-degree nitinol & gold-plated tungsten loop) and multiloop snare kit(2-45mm diameter, three interlaced nitinol loops) for foreign body retrieval, should come with flexible, reinforced, strain relief hub to reduce buckling and unique peel away insertion tool. usfda approved , ptca kit (1) three port manifold with knobs to turnright when open (2) one pressure line, (3) fluid connecting line, (4) contrast connecting line, (5) one three way stop cock, (6) one y-connector hemoststic valve with spring type push and release mechanism, (7) one inflation device with manometer upto 30 atm (easy to operate with luminescent dial), (8) one luer lock controlled syringe of 10 ml with finger grip, (9) insertion needle, (10) torque device.usfda approved , closed suction catheter for paediatrics number and color- coded graduations for controlled depth suctioning.separate y connectors available for different tubes in the pack.catheter is made up of medical grade silicon material.sizes are 5fr. , closed suction catheter for paediatrics number and color- coded graduations for controlled depth suctioning.separate y connectors available for different tubes in the pack.catheter is made up of medical grade silicon material. sizes are 6fr , closed suction catheter for paediatrics number and color- coded graduations for controlled depth suctioning.separate y connectors available for different tubes in the pack.catheter is made up of medical grade silicon material. sizes are 7fr. , closed suction catheter for paediatrics number and color- coded graduations for controlled depth suctioning.separate y connectors available for different tubes in the pack.catheter is made up of medical grade silicon material.sizes 8fr. , closed suction catheter for paediatrics number and color- coded graduations for controlled depth suctioning.separate y connectors available for different tubes in the pack.catheter is made up of medical grade silicon material.sizes are 10fr. , closed suction catheter for paediatrics number and color- coded graduations for controlled depth suctioning.separate y connectors available for different tubes in the pack.catheter is made up of medical grade silicon material. sizes 12fr. , paediatric endotracheal tube paediatric microcuff designed according to the paediatric anatomy.cuff is made up of polyurethane,thickness of cuff is 10 microns.microcuff seals at an average cuff pressure of 11 cmh2o.burst pressure of cuff is 805cmh2o.anatomically based intubation depth marking with precision bands.cuff with play mode function. sizes are 3mm. , paediatric endotracheal tube paediatric microcuff designed according to the paediatric anatomy.cuff is made up of polyurethane,thickness of cuff is 10 microns.microcuff seals at an average cuff pressure of 11 cmh2o.burst pressure of cuff is 805cmh2o.anatomically based intubation depth marking with precision bands.cuff with play mode function. sizes are 3.5mm. , paediatric endotracheal tube paediatric microcuff designed according to the paediatric anatomy.cuff is made up of polyurethane,thickness of cuff is 10 microns.microcuff seals at an average cuff pressure of 11 cmh2o.burst pressure of cuff is 805cmh2o.anatomically based intubation depth marking with precision bands.cuff with play mode function. sizes are 5.5mm , adult endotracheal tube cuff is made up of polyurethane.thickness of cuff is 10 microns.microcuff seals at an average cuff pressure of 20 cmh2o.burst pressure of cuff is 800cmh2o.cuff with play mode function. sizes 5.5mm. , adult endotracheal tube cuff is made up of polyurethane.thickness of cuff is 10 microns.microcuff seals at an average cuff pressure of 20 cmh2o.burst pressure of cuff is 800cmh2o.cuff with play mode function. sizes 10mm. , kimvent bal cath non bronchoscopic bal for bronchial aspirate sampling. can be performed in minutes at bedside. directional tip allows right or left lung sampling.maintains peep when used with supplied ventilator adapter. soft, cushioned, radiopaque tip for safe sampling. protected with outer catheter covering. t size 13fr . , kimvent bal cath non bronchoscopic bal for bronchial aspirate sampling. can be performed in minutes at bedside. directional tip allows right or left lung sampling.maintains peep when used with supplied ventilator adapter. soft, cushioned, radiopaque tip for safe sampling. protected with outer catheter covering. sizes 16fr. , disposable spo2 sensor it should be base on original nellcor technology with original oximax technology , catheter mount double swivel connector, it should have bronchoscopy port . it sholud be approved by us fda , gastrostomy feeding tube medical grade silicone construction.low profile design.tapered distal tip,silicone internal retention balloon.distal tip recessed at 5m.lproximal anti reflux valve.secur lok extention set connector mechanism,radiopaque stripe,gamma sterilized size – 12,length (0.8 – 5.0) , gastrostomy feeding tube medical grade silicone construction.low profile design.tapered distal tip,silicone internal retention balloon.distal tip recessed at 5m.lproximal anti reflux valve.secur lok extention set connector mechanism,radiopaque stripe,gamma sterilizedsize – 14 length (0.8 – 5.0) , gastrostomy feeding tube medical grade silicone construction.low profile design.tapered distal tip,silicone internal retention balloon.distal tip recessed at 5m.lproximal anti reflux valve.secur lok extention set connector mechanism,radiopaque stripe,gamma sterilizedsize – 16 length (0.8 – 5.0) , gastrostomy feeding tube medical grade silicone construction.low profile design.tapered distal tip,silicone internal retention balloon.distal tip recessed at 5m.lproximal anti reflux valve.secur lok extention set connector mechanism,radiopaque stripe,gamma sterilizedsize – 18,length (0.8 – 5.0) , gastrostomy feeding tube medical grade silicone construction.low profile design.tapered distal tip,silicone internal retention balloon.distal tip recessed at 5m.lproximal anti reflux valve.secur lok extention set connector mechanism,radiopaque stripe,gamma sterilizedsize – 20 length (0.8 – 5.0) , gastrostomy feeding tube medical grade silicone construction.low profile design.tapered distal tip,silicone internal retention balloon.distal tip recessed at 5m.lproximal anti reflux valve.secur lok extention set connector mechanism,radiopaque stripe,gamma sterilized size – 24fr length (0.8 – 5.0) , percutaneous endoscopic gastrostomy (peg) medical grade silicone construction.external retention ring .universal and bolus feeding port connectors,medication port.collapsible internal retention bumper.radiopaque stripe and bumper.tubing clamp.eto sterilized.sizes – 14fr , percutaneous endoscopic gastrostomy (peg) medical grade silicone construction.external retention ring .universal and bolus feeding port connectors,medication port.collapsible internal retention bumper.radiopaque stripe and bumper.tubing clamp.eto sterilized.sizes – 20fr , percutaneous endoscopic gastrostomy (peg) medical grade silicone construction.external retention ring .universal and bolus feeding port connectors,medication port.collapsible internal retention bumper.radiopaque stripe and bumper.tubing clamp.eto sterilized.sizes – 24fr , silk protein based sterile surgical pu foam dressing non adhesive biomodified, silk protein based, sterile, soft, conformable, absorbent, double layered polyurethene foam dressing comprised of silk protein 8% and asiaticoside nlt 0.6%, with super fluid handling capacity, decreases the risk of maceration,sterlization-gamma sterlized , silk protein & antimicrobial nanosilver based sterile surgical pu foam dressing non adhesive biomodified, silk protein & silver impregnated, soft, conformable, absorbent, double layered polyurethene foam dressing comprised of silk protein 8%, asiaticoside nlt 0.6% and silver 1.2%, with super fluid handling capacity, decreases the risk of maceration,sterlization-gamma sterlized , silk protein & antimicrobial silver based sterile surgical mesh wound dressing biomodified, bilaminated silk protein and silver wound dressing with mesh pores to facilitate the easy drainage of exudates, comprised of activated silk matrix 46% and asiaticoside nlt 0.6% and,sterlization-gamma sterlizedsilver :1.2%. non- adhesive, square / rectangular in shape,sterlization-gamma sterlized , silk protein & antimicrobial nanosilver based sterile surgical wound dressing sheet biomodified, bilaminated silk protein & silver based surgical wound dressing comprised of activated silk matrix 46% and asiaticoside 0.6% and silver :1.2%. non- adhesive, square / rectangular in shape,sterlization-gamma sterlized , silk protein derived sterile surgical meshed wound dressing biomodified, bilaminated silk protein wound dressing with mesh pores to facilitate the easy drainage of exudates, comprised of activated silk matrix 46% and asiaticoside nlt 0.6%. non- adhesive dressing, square / rectangular in shape,sterlization-gamma sterlized , silk protein based sterile surgical wound dressing sheet biomodified, bilaminated silk protein wound dressing comprised of activated silk matrix 46% and asiaticoside nlt 0.6%. non- adhesive dressing, square / rectangular shape,sterlization-gamma sterlized , silk protein based antimicrobial wound healing ointment loaded with asiaticoside and silver biomodified silk protein and silver based wound healing ointment comprised of silk powder 8% , asiaticoside nlt 0.6% and silver:1.2%,sterlization-gamma sterlized , silk protein and nanosilver based microbicidal sterile surgical wound dressing sprinkling powder bottle biomodified silk protein and silver based microbicidal sprinkling powder,comprised of silk powder 8%, asiaticoside nlt 0.6% and silver :1.2% . conforms to any wound shape and size, easy to apply,sterlization-gamma sterlized , silk protein based sterile surgical wound dressing sprinkling powder bottle biomodified silk protein based wound healing sprinkling powder,comprised of silk powder 8% and asiaticoside nlt 0.6% . conforms to any wound shape and size, easy to apply,sterlization-gamma sterlized , centella asiatica extract based skin moisturization and antiscar gel centella asiatica extract based skin moisturization and antiscar gel, comprised of centella asiatica extract, glycerol and vitamin e.,sterlization-gamma sterlized , silk protein based sterile surgical particle wound dressingbiomodified, bioabsorbable silk protein and collagen containing particle wound dressing, comprised of silk powder 8% , asiaticoside 0.6% and collagen ,having natural moisturizing factor(nmf), suitable for cavity wound and any kind of slow and non- healing wound,sterlization-gamma sterlized , silk protein and antimicrobial nanosilver based sterile surgical particle wound dressing 5ml biomodified, bioabsorbable silk protein, collagen and silver containing broadspectrum antimicrobial particle wound dressing ,comprised of silk powder 8%, asiaticoside 0.6% ,having natural moisturizing factor(nmf), suitable for deep, tunneling cavity wound or any kind of slow and non- healing wound,sterlization-gamma sterlized , silk protein and antimicrobial nanosilver based sterile surgical particle wound dressing 10ml biomodified, bioabsorbable silk protein, collagen and silver containing broadspectrum antimicrobial particle wound dressing ,comprised of silk powder 8%, asiaticoside 0.6% ,having natural moisturizing factor(nmf), suitable for deep, tunneling cavity wound or any kind of slow and non- healing wound,sterlization-gamma sterlized , silk protein based non-woven backed with pad & self adhesive border, water-repellent sterile surgical dressing 10x20cm, silk protein and nanocrystalline silver based highly conformable sterile antimicrobial dressing with adhesive backing and absorbent layer ,sterlization-gamma sterlized , silk protein based non-woven backed with pad & self adhesive border, water-repellent sterile surgical dressing 10x25cm, silk protein and nanocrystalline silver based highly conformable sterile antimicrobial dressing with adhesive backing and absorbent layer ,sterlization-gamma sterlized , silk protein based non-woven backed with pad & self adhesive border, water-repellent sterile surgical dressing 15x15cm silk protein and nanocrystalline silver based highly conformable sterile antimicrobial dressing with adhesive backing and absorbent layer ,sterlization-gamma sterlized , silk protein and pu foam pad with self adhesive border, water-proof dressing for post-operative scar or any scar management 10x20cm , silk protein based highly conformable sterile pu foam with antiscarring properties and adhesive backin,sterlization-gamma sterlized , silk protein and pu foam pad with self adhesive border, water-proof dressing for post-operative scar or any scar management 10x25cm , silk protein based highly conformable sterile pu foam with antiscarring properties and adhesive backin,sterlization-gamma sterlized , silk protein and pu foam pad with self adhesive border, water-proof dressing for post-operative scar or any scar management 10x21.5cm s silk protein based highly conformable sterile pu foam with antiscarring properties and adhesive backin,sterlization-gamma sterlized , silk protein, nanosilver and asiaticoside based pu film backed with pad & self adhesive border, water-proof sterile surgical dressing 9x21.5cm silk protein, nanocrystalline silver & asiaticoside based highly conformable sterile antimicrobial surgical and scar free wound healing dressing with adhesive backing and absorbent layer,sterlization-gamma sterlized , silk protein, nanosilver and asiaticoside based pu film backed with pad & self adhesive border, water-proof sterile surgical dressing 10x25cm silk protein, nanocrystalline silver & asiaticoside based highly conformable sterile antimicrobial surgical and scar free wound healing dressing with adhesive backing and absorbent layer,sterlization-gamma sterlized , silk protein and antimicrobial nanosilver impregnated non-adherent leno gauze sterile surgical wound dressing 10x10cm . silk protein & nanocrystalline silver based sterile, non-adherent, antimicrobial gauze dressing ,sterlization-gamma sterlized , silk protein and antimicrobial nanosilver impregnated non-adherent leno gauze sterile surgical wound dressing 10x25cm . silk protein & nanocrystalline silver based sterile, non-adherent, antimicrobial gauze dressing ,sterlization-gamma sterlized , silk protein impregnated non-adherent leno gauze sterile primary surgical wound dressing 10x10cm silk protein based sterile, non-adherent, antimicrobial gauze dressing ,sterlization-gamma sterlized , silk protein impregnated non-adherent leno gauze sterile primary surgical wound dressing 10x25cm . silk protein based sterile, non-adherent, antimicrobial gauze dressing ,sterlization-gamma sterlized , papain-urea & silk protein based wound debriding ointment and cream 25gm papain-urea based debriding ointment and cream for removal of necrotic tissue and slough in infected wounds, containing papain ip : 521700 units and urea ip : 100mg , papain-urea & silk protein based wound debriding ointment and cream 50gm papain-urea based debriding ointment and cream for removal of necrotic tissue and slough in infected wounds, containing papain ip : 521700 units and urea ip : 100mg , silk protein, asiaticoside and povidone iodine based broad spectrum topical antiseptic and antimicrobial wound healing ointment 25gm broad spectrum antiseptic and antimicrobial topical ointment containing povidone iodine usp: 5% w/w, silk protein, centella asiatica for prevention of skin and wound infections. , silk protein, asiaticoside and povidone iodine based broad spectrum topical antiseptic and antimicrobial wound healing ointment 50gm broad spectrum antiseptic and antimicrobial topical ointment containing povidone iodine usp: 5% w/w, silk protein, centella asiatica for prevention of skin and wound infections. , anti microbial gloves , anterior chamber iol pmma material, single piecekelman multiflex design5-6 mm optic size with 12-13 mm overall size biconvex power range +12 to +24should be iso or ce certified. manufacturer should be asked to sample for approval. , capsular tension ring standard capsular tension ringpmma material with one eyelet each at each end 10 mm to 12 mm overall diameter sterile should be iso/ce certified mfg. , iris hooks /retractors set of five disposable sterile iris hooks with soft silicon stopper sterile peek should be made pmma iso/ce certified mfg. , silicone rod for ptosis repair implantable flexible silicon rod attached to malleable sharp needles with a silicon sleeve. needlelength 60-70mm diameter 920 µ length of silicone rod 40cm, length of silicon sleeve 0.7 mm. , reusable anaesthetia face mask of silicone autocalvable & pure transparent. us fda approved and size should be mentioned on mask. , reusable anaesthetia face mask of silicone autocalvable & pure transparent. us fda approved and size should be mentioned on mask. , reusable anaesthetia face mask of silicone autocalvable & pure transparent. us fda approved and size should be mentioned on mask. , reusable anaesthetia face mask of silicone autocalvable & pure transparent. us fda approved and size should be mentioned on mask. , reusable anaesthetia face mask of silicone autocalvable & pure transparent. us fda approved and size should be mentioned on mask. , reusable anaesthetia face mask of silicone autocalvable & pure transparent. us fda approved and size should be mentioned on mask. , flow regulator extension set flow rate 2ml to 350ml per hour , sterile disposable hypodermic needle no. 18x1½ , sterile disposable hypodermic needle no. 21x1½ , sterile disposable hypodermic needle no. 23x1½ , neonatal single heated wire breathing system with auto fill humidification chamber in sterile pack and us fda approved. should be compatible every humidifier. , paed. single heated wire breathing system with auto fill humidification chamber in sterile pack and us fda approved. should be compatible every humidifier. , adult single heated wire breathing system with auto fill humidification chamber in sterile pack and us fda approved. should be compatible every humidifier. , neonatal high flow nasal cannula having 8 litre flow. should have soft tip . , pur-xro catheter 20 cm, 28g/1fr picc line with stylet, splitting needle with securing wings with 8 cm extension tubing (flow rate 1ml/min) , pur-xro catheter 30 cm, 24g/2fr picc line with split cannula and 10cm extension tubing over catheter (flow rate 0.2ml/min) , dead body bag 7x3 ft size leak proof material pp closed on all other sides and zipped on front or on 3 sides , introducer sheath with puncture needle for adults us fda approved• 10-11 cm long• pack must include 18 g, 6-7.5 cm long puncture needle: 0.035 or 0.038 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• integral side port with attached 3-way stopcock• with suture eye for securing sheath• kink resistant•with dilator-hub lock mechanism to prevent its back-out during insertion•with smooth and resistance free insertion , introducer sheath with puncture needle for adults us fda approved• 10-11 cm long• pack must include 18 g, 6-7.5 cm long puncture needle: 0.035 or 0.038 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• integral side port with attached 3-way stopcock• with suture eye for securing sheath• kink resistant• with dilator-hub lock mechanism to prevent its back-out during insertion• with smooth and resistance free insertion , intoducer sheath for adults (size 10 fr..)(standard length) us fda approved us fda + ce/ dgci approved• 10-11 cm long• 0.035 or 0.038 inch guide wire compatible•with haemostatic valve to prevent back leak and air aspiration• integral side port with attached 3-way stopcock• with suture eye for securing sheath• kink resistant• with dilator-hub lock mechanism to prevent its back-out during insertion• with smooth and resistance free insertion us fda + ce/ dgci approved , intoducer sheath for adults (size 11 fr.)(standard length) us fda approved us fda + ce/ dgci approved• 10-11 cm long• 0.035 or 0.038 inch guide wire compatible•with haemostatic valve to prevent back leak and air aspiration• integral side port with attached 3-way stopcock• with suture eye for securing sheath• kink resistant• with dilator-hub lock mechanism to prevent its back-out during insertion• with smooth and resistance free insertion us fda + ce/ dgci approved , long introducer sheath (20-30 cm long) (size 5fr..) us fda + ce/ dgci approved• sheath should be between 20-30 cm long• 0.035 or 0.038 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• integral side port with attached 3-way stopcock• with suture eye for securing sheath• kink resistant• with dilator-hub lock mechanism to prevent its back-out during insertion• with smooth and resistance free insertion , long introducer sheath (20-30 cm long) (size 6fr.) us fda + ce/ dgci approved• sheath should be between 20-30 cm long• 0.035 or 0.038 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• integral side port with attached 3-way stopcock• with suture eye for securing sheath• kink resistant • with dilator-hub lock mechanism to prevent its back-out during insertion• with smooth and resistance free insertion , long introducer sheath (20-30 cm long) (size 7fr.) us fda + ce/ dgci approved• sheath should be between 20-30 cm long• 0.035 or 0.038 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• integral side port with attached 3-way stopcock• with suture eye for securing sheath• kink resistant • with dilator-hub lock mechanism to prevent its back-out during insertion• with smooth and resistance free insertion , long introducer sheath (20-30 cm long) (size 8fr) us fda + ce/ dgci approved• sheath should be between 20-30 cm long• 0.035 or 0.038 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• integral side port with attached 3-way stopcock• with suture eye for securing sheath• kink resistant • with dilator-hub lock mechanism to prevent its back-out during insertion• with smooth and resistance free insertion , long introducer sheath (20-30 cm long) (size 9fr.) us fda + ce/ dgci approved• sheath should be between 20-30 cm long• 0.035 or 0.038 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• integral side port with attached 3-way stopcock• with suture eye for securing sheath• kink resistant • with dilator-hub lock mechanism to prevent its back-out during insertion• with smooth and resistance free insertion , long introducer sheath (20-30 cm long)(size 10fr..) us fda + ce/ dgci approved• sheath should be between 20-30 cm long• 0.035 or 0.038 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• integral side port with attached 3-way stopcock• with suture eye for securing sheath• kink resistant • with dilator-hub lock mechanism to prevent its back-out during insertion• with smooth and resistance free insertion , long introducer sheath (20-30 cm long)(size 11fr.) us fda + ce/ dgci approved• sheath should be between 20-30 cm long• 0.035 or 0.038 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• integral side port with attached 3-way stopcock• with suture eye for securing sheath• kink resistant• with dilator-hub lock mechanism to prevent its back-out during insertion• with smooth and resistance free insertion , trans radial introducer sheeths 4f us fda + ce/ dgci approved• sizes 4 french 10-20 cm long• pack must include 18 g,-21 g, 6-7.5 cm long puncture needle• 0.025 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• integral side port with attached 3-way stopcock• with suture eye for securing sheath• kink resistant • with dilator-hub lock mechanism to prevent its back-out during insertion• with smooth and resistance free insertion , trans radial introducer sheeths 5f us fda + ce/ dgci approved• sizes 5 french 10-20 cm long• pack must include 18 g,-21 g, 6-7.5 cm long puncture needle• 0.025 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• integral side port with attached 3-way stopcock• with suture eye for securing sheath• kink resistant • with dilator-hub lock mechanism to prevent its back-out during insertion• with smooth and resistance free insertion , trans radial introducer sheeths 6f us fda + ce/ dgci approved• sizes 6 french 10-20 cm long• pack must include 18 g,-21 g, 6-7.5 cm long puncture needle• 0.025 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• integral side port with attached 3-way stopcock• with suture eye for securing sheath• kink resistant• with dilator-hub lock mechanism to prevent its back-out during insertion• with smooth and resistance free insertion , steerable introducer sheeths 5f us fda + ce/ dgci approved• size 55 to 90 cms• to provide greater access to reaching target with ergonomic handle design• movable tip for different curves and torquability to ready vessel , steerable introducer sheeths 6fr us fda + ce/ dgci approved• size 55 to 90 cms• to provide greater access to reaching target with ergonomic handle design• movable tip for different curves and torquability to ready vessel , steerable introducer sheeths 7f us fda + ce/ dgci approved• size 55 to 90 cms• to provide greater access to reaching target with ergonomic handle design• movable tip for different curves and torquability to ready vessel , steerable introducer sheeths 8fus fda + ce/ dgci approved• size 55 to 90 cms•to provide greater access to reaching target with ergonomic handle design• movable tip for different curves and torquability to ready vessel , steerable introducer sheeths 9f us fda + ce/ dgci approved• size 55 to 90 cms• to provide greater access to reaching target with ergonomic handle design• movable tip for different curves and torquability to ready vessel , steerable introducer sheeths 10f us fda + ce/ dgci approved• size 55 to 90 cms• to provide greater access to reaching target with ergonomic handle design• movable tip for different curves and torquability to ready vessel , steerable introducer sheeths 11f us fda + ce/ dgci approved• size 55 to 90 cms• to provide greater access to reaching target with ergonomic handle design• movable tip for different curves and torquability to ready vessel , steerable introducer sheeths 12f us fda + ce/ dgci approved• size 55 to 90 cms• to provide greater access to reaching target with ergonomic handle design• movable tip for different curves and torquability to ready vessel , long braded introducer sheath – us fda approved us fda + ce/ dgci approved• should be 90 cm and above• 0.021 or 0.025 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• with integral side port with attached 3-way stopcock• with suture eye for securing sheath• kink resistant• with dilator-hub lock mechanism to prevent its back-out during insertion , long braded introducer sheath – us fda approved us fda + ce/ dgci approved• should be 90 cm and above• 0.021 or 0.025 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• with integral side port with attached 3-way stopcock• with suture eye for securing sheath• kink resistant• with dilator-hub lock mechanism to prevent its back-out during insertion , long braded introducer sheath – us fda approved us fda + ce/ dgci approved• should be 90 cm and above• 0.021 or 0.025 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• with integral side port with attached 3-way stopcock• with suture eye for securing sheath• kink resistant• with dilator-hub lock mechanism to prevent its back-out during insertion , long braded introducer sheath – us fda approved us fda + ce/ dgci approved• should be 90 cm and above• 0.021 or 0.025 inch guide wire compatible•with haemostatic valve to prevent back leak and air aspiration• with integral side port with attached 3-way stopcock• with suture eye for securing sheath• kink resistant• with dilator-hub lock mechanism to prevent its back-out during insertion , long braded contra lateral introducer sheath us fda + ce/ dgci approved• should be 20 - 90 cm and above• 0.021 or 0.025 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• with integral side port with attached 3-way stopcock• with suture eye for securing sheath• kink resistant• with dilator-hub lock mechanism to prevent its back-out during insertion q , long braded contra lateral introducer sheath us fda + ce/ dgci approved• should be 20 - 90 cm and above• 0.021 or 0.025 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• with integral side port with attached 3-way stopcock• with suture eye for securing sheath• kink resistant• with dilator-hub lock mechanism to prevent its back-out during insertion , long braded contra lateral introducer sheath us fda + ce/ dgci approved• should be 20 - 90 cm and above• 0.021 or 0.025 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• with integral side port with attached 3-way stopcock• with suture eye for securing sheath• kink resistant• with dilator-hub lock mechanism to prevent its back-out during insertion , long braded contra lateral introducer sheath us fda + ce/ dgci approved•should be 20 - 90 cm and above• 0.021 or 0.025 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• with integral side port with attached 3-way stopcock• with suture eye for securing sheath• kink resistant• with dilator-hub lock mechanism to prevent its back-out during insertion , long introducer sheath (30-50 cm long) (size 5fr..) us fda + ce/ dgci approved• between 30-50 cm long• 0.035 or 0.038 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• integral side port with attached 3-way stopcock• kink resistant• with dilator-hub lock mechanism to prevent its back-out during insertion• with smooth and resistance free insertion , long introducer sheath (30-50 cm long) (size 6 fr..) us fda + ce/ dgci approved• between 30-50 cm long• 0.035 or 0.038 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• integral side port with attached 3-way stopcock• kink resistant• with dilator-hub lock mechanism to prevent its back-out during insertion• with smooth and resistance free insertion , long introducer sheath (30-50 cm long) (size 7fr.) us fda + ce/ dgci approved• between 30-50 cm long• 0.035 or 0.038 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• integral side port with attached 3-way stopcock• kink resistant• with dilator-hub lock mechanism to prevent its back-out during insertion• with smooth and resistance free insertion , long introducer sheath (30-50 cm long) (size 8fr.) us fda + ce/ dgci approved• between 30-50 cm long• 0.035 or 0.038 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• integral side port with attached 3-way stopcock• kink resistant• with dilator-hub lock mechanism to prevent its back-out during insertion• with smooth and resistance free insertion , long introducer sheath (30-50 cm long) (size 9fr.) us fda + ce/ dgci approved• between 30-50 cm long• 0.035 or 0.038 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• integral side port with attached 3-way stopcock• kink resistant• with dilator-hub lock mechanism to prevent its back-out during insertion• with smooth and resistance free insertion , long introducer sheath (30-50 cm long)(size 10fr..) us fda + ce/ dgci approved• between 30-50 cm long• 0.035 or 0.038 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• integral side port with attached 3-way stopcock• kink resistant• with dilator-hub lock mechanism to prevent its back-out during insertion• with smooth and resistance free insertion , long introducer sheath (30-50 cm long)(size 11fr.) us fda + ce/ dgci approved• between 30-50 cm long• 0.035 or 0.038 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• integral side port with attached 3-way stopcock• kink resistant• with dilator-hub lock mechanism to prevent its back-out during insertion• with smooth and resistance free insertion , long introducer sheath dedicated for transradial access us fda + ce/ dgci approved• between 7-11 cm long• 0.021 or 0.025 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• integral side port with attached 3-way stopcock• with suture eye for securing sheath• kink resistant• with dilator-hub lock mechanism to prevent its back-out during insertion• with smooth and resistance free insertion , long introducer sheath dedicated for transradial access us fda + ce/ dgci approved• between 7-11 cm long • 0.021 or 0.025 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• integral side port with attached 3-way stopcock• with suture eye for securing sheath• kink resistant • with dilator-hub lock mechanism to prevent its back-out during insertion• with smooth and resistance free insertion , long introducer sheath dedicated for transradial access us fda + ce/ dgci approved• between 7-11 cm long• 0.021 or 0.025 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• integral side port with attached 3-way stopcock• with suture eye for securing sheath• kink resistant• with dilator-hub lock mechanism to prevent its back-out during insertion• with smooth and resistance free insertion , long introducer sheath dedicated for transradial access us fda + ce/ dgci approved• between 7-11 cm long• 0.021 or 0.025 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• integral side port with attached 3-way stopcock• with suture eye for securing sheath• kink resistant• with dilator-hub lock mechanism to prevent its back-out during insertion• with smooth and resistance free insertion , long introducer sheath us fda + ce/ dgci approved• should be 90 cm and above• 0.021 or 0.025 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• with integral side port with attached 3-way stopcock• with suture eye for securing sheath• kink resistant• with dilator-hub lock mechanism to prevent its back-out during insertion , long introducer sheath us fda + ce/ dgci approved• should be 90 cm and above• 0.021 or 0.025 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• with integral side port with attached 3-way stopcock• with suture eye for securing sheath• kink resistant• with dilator-hub lock mechanism to prevent its back-out during insertion , long introducer sheath us fda + ce/ dgci approved• should be 90 cm and above• 0.021 or 0.025 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• with integral side port with attached 3-way stopcock• with suture eye for securing sheath• kink resistant• with dilator-hub lock mechanism to prevent its back-out during insertion , long introducer sheath us fda + ce/ dgci approved• should be 90 cm and above• 0.021 or 0.025 inch guide wire compatible• with haemostatic valve to prevent back leak and air aspiration• with integral side port with attached 3-way stopcock• with suture eye for securing sheath• kink resistant• with dilator-hub lock mechanism to prevent its back-out during insertion , ptfe coated diagnostic guide wire – (regular length, regular stiffness) us fda + ce/ dgci approved· should be available in 0.025 inches size· should be between 145-180 cm long· should be available as straight & j-shaped tip· should be available in variable lengths of flexible/floppy end· should be available in variable j tip sizes· should be available fixed as well as movable core. , ptfe coated diagnostic guide wire – (regular length, regular stiffness) us fda + ce/ dgci approved· should be available in 0.032 inches size· should be between 145-180 cm long· should be available as straight & j-shaped tip· should be available in variable lengths of flexible/floppy end· should be available in variable j tip sizes· should be available fixed as well as movable core. , ptfe coated diagnostic guide wire – (regular length, regular stiffness) us fda + ce/ dgci approved· should be available in 0.035 size· should be between 145-180 cm long· should be available as straight & j-shaped tip· should be available in variable lengths of flexible/floppy end· should be available in variable j tip sizes· should be available fixed as well as movable core. , ptfe coated diagnostic guide wire – (regular length, regular stiffness) us fda + ce/ dgci approved· should be available in 0.038 inches size· should be between 145-180 cm long· should be available as straight & j-shaped tip· should be available in variable lengths of flexible/floppy end· should be available in variable j tip sizes· should be available fixed as well as movable core. , ptfe coated diagnostic guide wire – (exchange length, regular stiffness) us fda + ce/ dgci approved· should be available in 0.025 inches size· should be 240-300 cm long· should be available as straight or j-shaped tip· should be available fixed as well as movable core. , ptfe coated diagnostic guide wire – (exchange length, regular stiffness) us fda + ce/ dgci approved· should be available in 0.032, inches size· should be 240-300 cm long· should be available as straight or j-shaped tip· should be available fixed as well as movable core. , ptfe coated diagnostic guide wire – (exchange length, regular stiffness) us fda + ce/ dgci approved· should be available in , 0.035 inches size· should be 240-300 cm long· should be available as straight or j-shaped tip· should be available fixed as well as movable core. , ptfe coated diagnostic guide wire – (exchange length, regular stiffness) us fda + ce/ dgci approved· should be available in 0.038 inches size· should be 240-300 cm long· should be available as straight or j-shaped tip· should be available fixed as well as movable core. , ptfe coated diagnostic 0.032 inch guide wire – (exchange length, extra stiff shaft strength)-amplatz type us fda + ce/ dgci approved· should be available in 0.032 inches size· should be between 240-300 cm long· should be available as straight & j-shaped tip , ptfe coated diagnostic 0.032 inch guide wire – (exchange length, extra stiff shaft strength)-amplatz type us fda + ce/ dgci approved· should be available in 0.035 inches size· should be between 240-300 cm long· should be available as straight & j-shaped tip , ptfe coated diagnostic 0.032 inch guide wire – (exchange length, extra stiff shaft strength)-amplatz type us fda + ce/ dgci approved· should be available in 0.038 inches size· should be between 240-300 cm long· should be available as straight & j-shaped tip , hydrophilic diagnostic guide wire – radifocus tarumo type (regular length, regular stiffness) us fda + ce/ dgci approved· should be available in 0.025 inches size· should have superelastic alloy core·should have super flexible wire tip·should be available in straight and angled tip·should be between 120-300 cm long , hydrophilic diagnostic guide wire – radifocus tarumo type (regular length, regular stiffness) us fda + ce/ dgci approved· should be available in 0.032 inches size·should have superelastic alloy core·should have super flexible wire tip·should be available in straight and angled tip·should be between 120-300 cm long , hydrophilic diagnostic guide wire – radifocus tarumo type (regular length, regular stiffness) us fda + ce/ dgci approved·should be available in 0.035 inches size·should have superelastic alloy core·should have super flexible wire tip· should be available in straight and angled tip· should be between 120-300 cm long , hydrophilic diagnostic guide wire – radifocus tarumo type (regular length, regular stiffness) us fda + ce/ dgci approved· should be available in 0.038 inches size·should have superelastic alloy core·should have super flexible wire tip·should be available in straight and angled tip·should be between 120-300 cm long , radiofocus miniplastic guidewire (, regular stiffness) us fda + ce/ dgci approved• sould be available in 0.025 inchessize• should have superelastic alloy core•should have super flexible wire tip•should be available in straight and angled tip•should be between 150-180 cm long , radiofocus miniplastic guidewire (, regular stiffness) us fda + ce/ dgci approved• sould be available in 0.032, inches size• should have superelastic alloy core•should have super flexible wire tip• should be available in straight and angled tip• should be between 150-180 cm long , radiofocus miniplastic guidewire (, regular stiffness) us fda + ce/ dgci approved• sould be available in 0.035 inches size• should have superelastic alloy core• should have super flexible wire tip• should be available in straight and angled tip•should be between 150-180 cm long , radiofocus miniplastic guidewire (, regular stiffness) us fda + ce/ dgci approved• sould be available in 0.038 inches size•should have superelastic alloy core•should have super flexible wire tip• should be available in straight and angled tip•should be between 150-180 cm long , radiofocus miniplastic guidewire (long length) us fda + ce/ dgci approved• should be available in 0.025, inches size• should have superelastic alloy core•should have super flexible wire tip• should be available in straight and angled tip• should be between 260cm, 300 cm50-180 cm longus fda + ce/ dgci approved , radiofocus miniplastic guidewire (long length) us fda + ce/ dgci approved• should be available in 0.032 inches size• should have superelastic alloy core•should have super flexible wire tip• should be available in straight and angled tip•should be between 260cm, 300 cm50-180 cm longus fda + ce/ dgci approved , radiofocus miniplastic guidewire (long length) us fda + ce/ dgci approved• should be available in 0.038 inches size•should have superelastic alloy core• should have super flexible wire tip• should be available in straight and angled tip•should be between 260cm, 300 cm50-180 cm longus fda + ce/ dgci approved , judkins catheter (jr) right judkins catheters in various standard curves and lengths. , judkins catheter (jr) right judkins catheters in various standard curves and lengths. , judkins catheter (jr) right judkins catheters in various standard curves and lengths. , judkins catheter (jr) right judkins catheters in various standard curves and lengths. , judkins catheter (jr) right judkins catheters in various standard curves and lengths. , judkins catheter (jl) us fda + ce/ dgci approved ·left judkins catheters in various standard curves and lengths. , judkins catheter (jl) us fda + ce/ dgci approved ·left judkins catheters in various standard curves and lengths. , judkins catheter (jl) us fda + ce/ dgci approved ·left judkins catheters in various standard curves and lengths. , judkins catheter (jl) us fda + ce/ dgci approved ·left judkins catheters in various standard curves and lengths. , judkins catheter (jl) us fda + ce/ dgci approved ·left judkins catheters in various standard curves and lengths. , judkins catheter pigtail us fda + ce/ dgci approved left and right judkins catheters in various standard curves and lengths. , judkins catheter pigtail us fda + ce/ dgci approved left and right judkins catheters in various standard curves and lengths. , judkins catheter pigtail us fda + ce/ dgci approved left and right judkins catheters in various standard curves and lengths. , judkins catheter pigtail us fda + ce/ dgci approved left and right judkins catheters in various standard curves and lengths. , judkins catheter pigtail us fda + ce/ dgci approved left and right judkins catheters in various standard curves and lengths. , multipurpose catheter us fda + ce/ dgci approved multipurpose catheters in various standard curves and lengths. , multipurpose catheter us fda + ce/ dgci approved multipurpose catheters in various standard curves and lengths. , multipurpose catheter us fda + ce/ dgci approved multipurpose catheters in various standard curves and lengths. , multipurpose catheter us fda + ce/ dgci approved multipurpose catheters in various standard curves and lengths. , multipurpose catheter us fda + ce/ dgci approved multipurpose catheters in various standard curves and lengths. , amplatz catheter us fda + ce/ dgci approved amplatz left (al) catheter in various standard curves and lengths. · , amplatz catheter us fda + ce/ dgci approved amplatz left (al) catheter in various standard curves and lengths. · , amplatz catheter us fda + ce/ dgci approved amplatz left (al) catheter in various standard curves and lengths. · , amplatz catheter us fda + ce/ dgci approved amplatz left (al) catheter in various standard curves and lengths. · , amplatz catheter us fda + ce/ dgci approved amplatz left (al) catheter in various standard curves and lengths. · , amplatz catheter us fda + ce/ dgci approved amplatz right (ar) catheter in various standard curves and lengths. · , amplatz catheter us fda + ce/ dgci approved amplatz right (ar) catheter in various standard curves and lengths. · , amplatz catheter us fda + ce/ dgci approved amplatz right (ar) catheter in various standard curves and lengths. · , amplatz catheter us fda + ce/ dgci approved amplatz right (ar) catheter in various standard curves and lengths. · , amplatz catheter us fda + ce/ dgci approved amplatz right (ar) catheter in various standard curves and lengths. · , internal mammary catheter us fda + ce/ dgci approved · in various standard curves and lengths. , internal mammary catheter us fda + ce/ dgci approved · in various standard curves and lengths. , internal mammary catheter us fda + ce/ dgci approved · in various standard curves and lengths. , internal mammary catheter us fda + ce/ dgci approved · in various standard curves and lengths. , internal mammary catheter us fda + ce/ dgci approved · in various standard curves and lengths. , by-pass graft catheter us fda + ce/ dgci approved, in various standard curves and lengths. , by-pass graft catheter us fda + ce/ dgci approved, in various standard curves and lengths. , by-pass graft catheter us fda + ce/ dgci approved, in various standard curves and lengths. , by-pass graft catheter us fda + ce/ dgci approved, in various standard curves and lengths. , by-pass graft catheter us fda + ce/ dgci approved, in various standard curves and lengths. , transradial diagnostic coronary catheter tiger type diagnostic coronary catheters of tig curves and lengths dedicated for trans radial coronary angiography and brachial approach also us fda + ce/ dgci approved · , transradial diagnostic coronary catheter tiger type diagnostic coronary catheters of tig curves and lengths dedicated for trans radial coronary angiography and brachial approach also us fda + ce/ dgci approved · , transradial diagnostic coronary catheter tiger type diagnostic coronary catheters of tig curves and lengths dedicated for trans radial coronary angiography and brachial approach also us fda + ce/ dgci approved · , transradial diagnostic coronary catheter tiger type diagnostic coronary catheters of tig curves and lengths dedicated for trans radial coronary angiography and brachial approach also us fda + ce/ dgci approved · , transradial diagnostic coronary catheter tiger type diagnostic coronary catheters of tig curves and lengths dedicated for trans radial coronary angiography and brachial approach also us fda + ce/ dgci approved · , nih catheter us fda + ce/ dgci approved ·in various standard curves and lengths. , nih catheter us fda + ce/ dgci approved ·in various standard curves and lengths. , nih catheter us fda + ce/ dgci approved ·in various standard curves and lengths. , nih catheter us fda + ce/ dgci approved ·in various standard curves and lengths. , nih catheter us fda + ce/ dgci approved ·in various standard curves and lengths. , cournard catheter us fda + ce/ dgci approved ·in various standard curves and lengths. , cournard catheter us fda + ce/ dgci approved ·in various standard curves and lengths. , cournard catheter us fda + ce/ dgci approved ·in various standard curves and lengths. , cournard catheter us fda + ce/ dgci approved ·in various standard curves and lengths. , cournard catheter us fda + ce/ dgci approved ·in various standard curves and lengths. , introducer sheaths for pediatric use (size 4 fr.) with j tip/straight introducer wire us fda + ce/ dgci approved· between 5.5-7.5 cm long· 0.021 inch straight introducer guide wire· with haemostatic valve to prevent back leak and air aspiration· with integral side port with attached 3-way stopcock· with suture eye for securing sheath· kink resistant· with dilator-hub lock mechanism to prevent its back-out during insertion· should have smooth and resistance free insertion , introducer sheaths for pediatric use (size 5 fr.) with j tip/straight introducer wire us fda + ce/ dgci approved· between 5.5-7.5 cm long· 0.021 inch straight introducer guide wire· with haemostatic valve to prevent back leak and air aspiration· with integral side port with attached 3-way stopcock· with suture eye for securing sheath· kink resistant· with dilator-hub lock mechanism to prevent its back-out during insertion· should have smooth and resistance free insertion , introducer sheaths for pediatric use (size 6 fr.) with j tip/straight introducer wire us fda + ce/ dgci approved· between 5.5-7.5 cm long· 0.021 inch straight introducer guide wire· with haemostatic valve to prevent back leak and air aspiration· with integral side port with attached 3-way stopcock· with suture eye for securing sheath· kink resistant· with dilator-hub lock mechanism to prevent its back-out during insertion· should have smooth and resistance free insertion , judkins catheter (pediatric) us fda + ce/ dgci approved·left and right judkins catheters in various standard curves and lengths· must be fda approved , judkins catheter (pediatric) us fda + ce/ dgci approved·left and right judkins catheters in various standard curves and lengths· must be fda approved , judkins catheter (pediatric) us fda + ce/ dgci approved·left and right judkins catheters in various standard curves and lengths· must be fda approved , special judkins coronary catheter with 2.5 cm curve (pediatric) us fda + ce/ dgci approved , special judkins coronary catheter with 2.5 cm curve (pediatric) us fda + ce/ dgci approved , special judkins coronary catheter with 2.5 cm curve (pediatric) us fda + ce/ dgci approved , angiographic double leumen tracking catheter us fda + ce/ dgci approved , angiographic double leumen tracking catheter us fda + ce/ dgci approved , angiographic double leumen tracking catheter us fda + ce/ dgci approved , 3- ‘french’ diagnostic catheters for neonatal use us fda + ce/ dgci approved· pigtail, judkins, multipurpose, cobra and other diagnostic catheters of 3 fr. size·varying lengths and shapes , swan ganz catheter us fda + ce/ dgci approved , swan ganz catheter us fda + ce/ dgci approved , balloon tipped angiography catheter us fda + ce/ dgci approved , balloon tipped angiography catheter us fda + ce/ dgci approved , balloon tipped angiography catheter us fda + ce/ dgci approved , berman catheter us fda + ce/ dgci approved· sizes· should have 6-8 holes proximal to the balloon for dye injection· catheter should be tapered at tip to ensure uniform diameter of the whole catheter· 10 cm marking along catheter body to confirm insertion depth , berman catheter us fda + ce/ dgci approved· should have 6-8 holes proximal to the balloon for dye injection·catheter should be tapered at tip to ensure uniform diameter of the whole catheter·10 cm marking along catheter body to confirm insertion depth , berman catheter us fda + ce/ dgci approved· should have 6-8 holes proximal to the balloon for dye injection·catheter should be tapered at tip to ensure uniform diameter of the whole catheter·10 cm marking along catheter body to confirm insertion depth , berman catheter us fda + ce/ dgci approved· should have 6-8 holes proximal to the balloon for dye injection· catheter should be tapered at tip to ensure uniform diameter of the whole catheter· 10 cm marking along catheter body to confirm insertion depth , reverse berman catheter us fda + ce/ dgci approved• catheter should be tapered at tip to ensure uniform diameter of the whole catheter• should have holes proximal to the balloon for dye injection• should have a hole at the proximal tip to allow the passage over the wire , reverse berman catheter us fda + ce/ dgci approved• catheter should be tapered at tip to ensure uniform diameter of the whole catheter• should have holes proximal to the balloon for dye injection• should have a hole at the proximal tip to allow the passage over the wire , reverse berman catheter us fda + ce/ dgci approved• catheter should be tapered at tip to ensure uniform diameter of the whole catheter• should have holes proximal to the balloon for dye injection• should have a hole at the proximal tip to allow the passage over the wire , reverse berman catheter us fda + ce/ dgci approved• catheter should be tapered at tip to ensure uniform diameter of the whole catheter• should have holes proximal to the balloon for dye injection• should have a hole at the proximal tip to allow the passage over the wire , arterial pressure monitor lines (100 cm long) us fda + ce/ dgci approved• should be soft and kink resistant• should give reliable pressure measurements• should have male luer lock connection at one end and a female luer lock connection at the other end• should meet highest medical industrial standards for arterial pressure lines• quality certification should be provided from authorized agencies. , arterial pressure monitor lines (150 cm long) us fda + ce/ dgci approved• should be soft and kink resistant• should give reliable pressure measurements• should have male luer lock connection at one end and a female luer lock connection at the other end• should meet highest medical industrial standards for arterial pressure lines• quality certification should be provided from authorized agencies. , arterial pressure monitor lines (200 cm long) us fda + ce/ dgci approved• should be soft and kink resistant• should give reliable pressure measurements• should have male luer lock connection at one end and a female luer lock connection at the other end• should meet highest medical industrial standards for arterial pressure lines• quality certification should be provided from authorized agencies. , straight long introducer sheath with hydrophilic introducer guide wire us fda + ce/ dgci approved· 16 cm and above long length, with 0.035 or 0.038 inch hydrophilic mini guide wire .with plastic cannula for arterial puncture , straight long introducer sheath with hydrophilic introducer guide wire us fda + ce/ dgci approved· 16 cm and above long length, with 0.035 or 0.038 inch hydrophilic mini guide wire .with plastic cannula for arterial puncture , straight long introducer sheath with hydrophilic introducer guide wire us fda + ce/ dgci approved· 16 cm and above long length,with 0.035 or 0.038 inch hydrophilic mini guide wire .with plastic cannula for arterial puncture , straight long introducer sheath with hydrophilic introducer guide wire us fda + ce/ dgci approved·16 cm and above long length,with 0.035 or 0.038 inch hydrophilic mini guide wire .with plastic cannula for arterial puncture , straight long introducer sheath with hydrophilic introducer guide wire us fda + ce/ dgci approved·16 cm and above long length, with 0.035 or 0.038 inch hydrophilic mini guide wire .with plastic cannula for arterial puncture , straight long introducer sheath with hydrophilic introducer guide wire us fda + ce/ dgci approved·16 cm and above long length, with 0.035 or 0.038 inch hydrophilic mini guide wire .with plastic cannula for arterial puncture , straight reinforced sheath with hydrophilic coating us fda + ce/ dgci approved• more than 60 cm long with side arm port• with 0.035 or 0.038 inch guide wire compatible•with radio-opaque tip , straight reinforced sheath with hydrophilic coating us fda + ce/ dgci approved• more than 60 cm long with side arm port• with 0.035 or 0.038 inch guide wire compatible with radio-opaque tip , straight reinforced sheath with hydrophilic coating us fda + ce/ dgci approved more than 60 cm long with side arm port• with 0.035 or 0.038 inch guide wire compatible• with radio-opaque tip , straight reinforced sheath with hydrophilic coating us fda + ce/ dgci approved• more than 60 cm long with side arm port• with 0.035 or 0.038 inch guide wire compatible•with radio-opaque tip , straight reinforced sheath with hydrophilic coating us fda + ce/ dgci approved• more than 60 cm long with side arm port•with 0.035 or 0.038 inch guide wire compatible•with radio-opaque tip , straight reinforced sheath with hydrophilic coating us fda + ce/ dgci approved• more than 60 cm long with side arm port.with 0.035 or 0.038 inch guide wire compatible• with radio-opaque tip , straight reinforced sheath with hydrophilic coating us fda + ce/ dgci approved• more than 60 cm long with side arm port•with 0.035 or 0.038 inch guide wire compatible with radio-opaque tip , long sheath for contra – lateral iliac/ femoral access us fda + ce/ dgci approved•should be kink resistant with a reinforcement mechanism • should be low friction with inner coating to allow catheter manipulation• should have distal radio-opaque tip for enhanced visibility on fluoroscopy• should have smooth transition from dilator to seath• should have a proximal hemostasis valve/ provision for tuohyborst valve• should be color coded for size identification• should be available in 4f size with the largest id• should have lengths ranging from 40-110 cm , long sheath for contra – lateral iliac/ femoral access us fda + ce/ dgci approved• should be kink resistant with a reinforcement mechanism • should be low friction with inner coating to allow catheter manipulation• should have distal radio-opaque tip for enhanced visibility on fluoroscopy• should have smooth transition from dilator to seath• should have a proximal hemostasis valve/ provision for tuohyborst valve• should be color coded for size identification• should be available in 5f size with the largest id• should have lengths ranging from 40-110 cm , long sheath for contra – lateral iliac/ femoral access us fda + ce/ dgci approved• should be kink resistant with a reinforcement mechanism • should be low friction with inner coating to allow catheter manipulation• should have distal radio-opaque tip for enhanced visibility on fluoroscopy• should have smooth transition from dilator to seath• should have a proximal hemostasis valve/ provision for tuohyborst valve• should be color coded for size identification• should be available in 6f size with the largest id• should have lengths ranging from 40-110 cm , long sheath for contra – lateral iliac/ femoral access us fda + ce/ dgci approved• should be kink resistant with a reinforcement mechanism • should be low friction with inner coating to allow catheter manipulation• should have distal radio-opaque tip for enhanced visibility on fluoroscopy• should have smooth transition from dilator to seath• should have a proximal hemostasis valve/ provision for tuohyborst valve• should be color coded for size identification• should be available in 7 f size with the largest id• should have lengths ranging from 40-110 cm q , long sheath for contra – lateral iliac/ femoral access us fda + ce/ dgci approved• should be kink resistant with a reinforcement mechanism • should be low friction with inner coating to allow catheter manipulation• should have distal radio-opaque tip for enhanced visibility on fluoroscopy• should have smooth transition from dilator to seath• should have a proximal hemostasis valve/ provision for tuohyborst valve• should be color coded for size identification• should be available in 8 f size with the largest id• should have lengths ranging from 40-110 cm , long sheath for contra – lateral iliac/ femoral access us fda + ce/ dgci approved• should be kink resistant with a reinforcement mechanism• should be low friction with inner coating to allow catheter manipulation• should have distal radio-opaque tip for enhanced visibility on fluoroscopy• should have smooth transition from dilator to seath• should have a proximal hemostasis valve/ provision for tuohyborst valve• should be color coded for size identification• should be available in 9 f size with the largest id• should have lengths ranging from 40-110 cm , mullin’s sheath for special dilation us fda + ce/ dgci approved should be in septal puncture needle should be in -6f septal puncture needle , angio.kit/ptca kit (3 port many fold with attached tubing one pressure line + two iv set connecting tube and two leurlock syringe ) us fda / ce/ approved , micro catheter for super selective catherization usfda/ce approved , micro catheter for super selective catherization usfda/ce approved , micro catheter for super selective catherization usfda/ce approved , micro catheter for super selective catherization usfda/ce approved , multi side port catheter infusion for catheter directed thromobolysis usa/fda/ce approved , clot retrieval sheath usa/fda/ce approved aspiration catheter 16 f including flow retriever catheter 19-25 mm,15-18mm ,11-14 mm , clot retrieval sheath usa/fda/ce approved aspiration catheter 20 f including flow retriever catheter 19-25 mm,15-18mm ,11-14 mm , clot retrieval sheath usa/fda/ce approved aspiration catheter 24 f including flow retriever catheter 19-25 mm,15-18mm ,11-14 mm , loadable microsphere for embolisation of tumour super absobent polymer drug eluting microsphere for tace (trans arterial chemo ambolization )usa/fda/ce approved , loadable microsphere for embolisation of tumour super absobent polymer drug eluting microsphere for tace (trans arterial chemo ambolization ) usa/fda/ce approved , loadable microsphere for embolisation of tumour super absobent polymer drug eluting microsphere for tace (trans arterial chemo ambolization ) usa/fda/ce approved , pcd set puncture needle 18g,0.035,j stiff stiff wire 0.035/80 cm ,dilator set ,pig tail /malecot catheter 8-24f , ring biliary catheter usa/fda/ce approved catheter 8.5 f/10/3 compatible 0.038 length~40 cm ,catheter side ports -32 ,side port segment length 8 cm ,catheter introducer, stiffening cannula ,secured device , venaseal closure system for varicose veins usa/fda approved n butyl based adhesive formation 50/90/105/120 cm 145 cm(3/4/6/8 f ,014/0.35 compatible , liver access and biopsy needle set usa/fda approved usa/fda approved 18g/60 cm biopsy needle ,14 g cannula /53.5 cm length sheath 7f , tran jugular intrahepatic porto sytemic shunt (tips set ) intoducer 10f/40 cm ,toclar diameter 0.038 legth60 cm ,cannula 14 g/51.5 cm , percutaneous gastrostomy balloon retention tube set catheter -12-20 f,length -10 cm ,balloon 5-20 ml , biopsy guns - should be spring loaded disposable automatic biopsy gun. should have one handed cocking mechanism with non-roll handle design. should have angled deep sample notch for enhanced needle action. should have choice of two firing buttons/dual triger with size color coding.should have penetration depth of 22mm. should have sharp-beveled trocar. should have round ergonomic handle with no-fire lock. should have etched needle tip is grit blasted. should be available in different gauge size 14,16,18,20 with length size cm 10, 16,20, 25. with compatible disposable coaxial needle: should be available in all sizes compatible with disposable core biopsy instrument/gun. should have color coded depth stopper that indicate the size and match with compatible size of disposable automatic core biopsy gun/instrument. should have option of blunt tip & sharp tip trocar for risk free penetration option. should be available in gauze size 13,15,17,19 with different length size cm 7.8, 13.8. usfda/ce approved , biopsy guns - should be spring loaded disposable automatic biopsy gun. should have one handed cocking mechanism with non-roll handle design. should have angled deep sample notch for enhanced needle action. should have choice of two firing buttons/dual triger with size color coding.should have penetration depth of 22mm. should have sharp-beveled trocar. should have round ergonomic handle with no-fire lock. should have etched needle tip is grit blasted. should be available in different gauge size 14,16,18,20 with length size cm 10, 16,20, 25. with compatible disposable coaxial needle: should be available in all sizes compatible with disposable core biopsy instrument/gun. should have color coded depth stopper that indicate the size and match with compatible size of disposable automatic core biopsy gun/instrument. should have option of blunt tip & sharp tip trocar for risk free penetration option. should be available in gauze size 13,15,17,19 with different length size cm 7.8, 13.8. usfda/ce approved , biopsy guns - should be spring loaded disposable automatic biopsy gun. should have one handed cocking mechanism with non-roll handle design. should have angled deep sample notch for enhanced needle action. should have choice of two firing buttons/dual triger with size color coding.should have penetration depth of 22mm. should have sharp-beveled trocar. should have round ergonomic handle with no-fire lock. should have etched needle tip is grit blasted. should be available in different gauge size 14,16,18,20 with length size cm 10, 16,20, 25. with compatible disposable coaxial needle: should be available in all sizes compatible with disposable core biopsy instrument/gun. should have color coded depth stopper that indicate the size and match with compatible size of disposable automatic core biopsy gun/instrument. should have option of blunt tip & sharp tip trocar for risk free penetration option. should be available in gauze size 13,15,17,19 with different length size cm 7.8, 13.8. usfda/ce approved , biopsy guns - should be spring loaded disposable automatic biopsy gun. should have one handed cocking mechanism with non-roll handle design. should have angled deep sample notch for enhanced needle action. should have choice of two firing buttons/dual triger with size color coding.should have penetration depth of 22mm. should have sharp-beveled trocar. should have round ergonomic handle with no-fire lock. should have etched needle tip is grit blasted. should be available in different gauge size 14,16,18,20 with length size cm 10, 16,20, 25. with compatible disposable coaxial needle: should be available in all sizes compatible with disposable core biopsy instrument/gun. should have color coded depth stopper that indicate the size and match with compatible size of disposable automatic core biopsy gun/instrument. should have option of blunt tip & sharp tip trocar for risk free penetration option. should be available in gauze size 13,15,17,19 with different length size cm 7.8, 13.8. usfda/ce approved , biopsy guns - should be spring loaded disposable automatic biopsy gun. should have one handed cocking mechanism with non-roll handle design. should have angled deep sample notch for enhanced needle action. should have choice of two firing buttons/dual triger with size color coding.should have penetration depth of 22mm. should have sharp-beveled trocar. should have round ergonomic handle with no-fire lock. should have etched needle tip is grit blasted. should be available in different gauge size 14,16,18,20 with length size cm 10, 16,20, 25. with compatible disposable coaxial needle: should be available in all sizes compatible with disposable core biopsy instrument/gun. should have color coded depth stopper that indicate the size and match with compatible size of disposable automatic core biopsy gun/instrument. should have option of blunt tip & sharp tip trocar for risk free penetration option. should be available in gauze size 13,15,17,19 with different length size cm 7.8, 13.8. usfda/ce approved , biopsy guns - should be spring loaded disposable automatic biopsy gun. should have one handed cocking mechanism with non-roll handle design. should have angled deep sample notch for enhanced needle action. should have choice of two firing buttons/dual triger with size color coding.should have penetration depth of 22mm. should have sharp-beveled trocar. should have round ergonomic handle with no-fire lock. should have etched needle tip is grit blasted. should be available in different gauge size 14,16,18,20 with length size cm 10, 16,20, 25. with compatible disposable coaxial needle: should be available in all sizes compatible with disposable core biopsy instrument/gun. should have color coded depth stopper that indicate the size and match with compatible size of disposable automatic core biopsy gun/instrument. should have option of blunt tip & sharp tip trocar for risk free penetration option. should be available in gauze size 13,15,17,19 with different length size cm 7.8, 13.8. usfda/ce approved , biopsy guns - should be spring loaded disposable automatic biopsy gun. should have one handed cocking mechanism with non-roll handle design. should have angled deep sample notch for enhanced needle action. should have choice of two firing buttons/dual triger with size color coding.should have penetration depth of 22mm. should have sharp-beveled trocar. should have round ergonomic handle with no-fire lock. should have etched needle tip is grit blasted. should be available in different gauge size 14,16,18,20 with length size cm 10, 16,20, 25. with compatible disposable coaxial needle: should be available in all sizes compatible with disposable core biopsy instrument/gun. should have color coded depth stopper that indicate the size and match with compatible size of disposable automatic core biopsy gun/instrument. should have option of blunt tip & sharp tip trocar for risk free penetration option. should be available in gauze size 13,15,17,19 with different length size cm 7.8, 13.8. usfda/ce approved , biopsy guns - should be spring loaded disposable automatic biopsy gun. should have one handed cocking mechanism with non-roll handle design. should have angled deep sample notch for enhanced needle action. should have choice of two firing buttons/dual triger with size color coding.should have penetration depth of 22mm. should have sharp-beveled trocar. should have round ergonomic handle with no-fire lock. should have etched needle tip is grit blasted. should be available in different gauge size 14,16,18,20 with length size cm 10, 16,20, 25. with compatible disposable coaxial needle: should be available in all sizes compatible with disposable core biopsy instrument/gun. should have color coded depth stopper that indicate the size and match with compatible size of disposable automatic core biopsy gun/instrument. should have option of blunt tip & sharp tip trocar for risk free penetration option. should be available in gauze size 13,15,17,19 with different length size cm 7.8, 13.8. usfda/ce approved , biopsy guns - should be spring loaded disposable automatic biopsy gun. should have one handed cocking mechanism with non-roll handle design. should have angled deep sample notch for enhanced needle action. should have choice of two firing buttons/dual triger with size color coding.should have penetration depth of 22mm. should have sharp-beveled trocar. should have round ergonomic handle with no-fire lock. should have etched needle tip is grit blasted. should be available in different gauge size 14,16,18,20 with length size cm 10, 16,20, 25. with compatible disposable coaxial needle: should be available in all sizes compatible with disposable core biopsy instrument/gun. should have color coded depth stopper that indicate the size and match with compatible size of disposable automatic core biopsy gun/instrument. should have option of blunt tip & sharp tip trocar for risk free penetration option. should be available in gauze size 13,15,17,19 with different length size cm 7.8, 13.8. usfda/ce approved , biopsy guns - should be spring loaded disposable automatic biopsy gun. should have one handed cocking mechanism with non-roll handle design. should have angled deep sample notch for enhanced needle action. should have choice of two firing buttons/dual triger with size color coding.should have penetration depth of 22mm. should have sharp-beveled trocar. should have round ergonomic handle with no-fire lock. should have etched needle tip is grit blasted. should be available in different gauge size 14,16,18,20 with length size cm 10, 16,20, 25. with compatible disposable coaxial needle: should be available in all sizes compatible with disposable core biopsy instrument/gun. should have color coded depth stopper that indicate the size and match with compatible size of disposable automatic core biopsy gun/instrument. should have option of blunt tip & sharp tip trocar for risk free penetration option. should be available in gauze size 13,15,17,19 with different length size cm 7.8, 13.8. usfda/ce approved , breast nodule localizationwire should have curved locking element that provide superior migration resistance. the localization wire can be repositioned or removed after placement if required. usfda/ce approved , disposable semi-automatic core biopsy instrument with compatible coaxial needle. should be available with dual penetration throw of 10 and 20mm in single instrument. should be available with fire ready indicator. should be available with compatible coaxial needle set with a blunt tip needle & trocar needle. should be usfda approved. , ultra clip disposable breast tissue marker should be available in coil shape & ribbon shape. should have color coded dual triggers identify different marker shape. should be visible in ultrasound, mri, mammography imaging. should be available in needle size of 17 gauge. should be available in coil shape and ribbon shape. , bone marrow biopsy needle with diamond bevel tip & tapered distal canula. disposable bone marrow biopsy needle should have ergonomic t- handle design with seprate handle cap. should have trocar/diamond tip for easy coring of bone. should have triple crown cannula tip with 6 facets.should be available with narrow acquition cardle with sample size verification marking should be available in 8,11,13 gauze usfda/ce approved , bone marrow biopsy needle with diamond bevel tip & tapered distal canula. disposable bone marrow biopsy needle should have ergonomic t- handle design with seprate handle cap. should have trocar/diamond tip for easy coring of bone. should have triple crown cannula tip with 6 facets.should be available with narrow acquition cardle with sample size verfication marking should be available in 8,11,13 gauze usfda/ce approved , bone marrow biopsy needle with diamond bevel tip & tapered distal canula. disposable bone marrow biopsy needle should have ergonomic t- handle design with seprate handle cap. should have trocar/diamond tip for easy coring of bone. should have triple crown cannula tip with 6 facets.should be available with narrow acquition cardle with sample size verfication marking should be available in 8,11,13 gauze usfda/ce approved , silicone foleys catheter with three noble metal alloy coating consisting of gold, silver & palladium (coated internally & externally surfaces) , silicone foleys catheter with three noble metal alloy coating consisting of gold, silver & palladium (coated internally & externally surfaces) , silicone foleys catheter with three noble metal alloy coating consisting of gold, silver & palladium (coated internally & externally surfaces) , silicone foleys catheter with three noble metal alloy coating consisting of gold, silver & palladium (coated internally & externally surfaces) , silicone foleys catheter with three noble metal alloy coating consisting of gold, silver & palladium (coated internally & externally surfaces) , silicone foleys catheter with three noble metal alloy coating consisting of gold, silver & palladium (coated internally & externally surfaces) , silicone foleys catheter with three noble metal alloy coating consisting of gold, silver & palladium (coated internally & externally surfaces) , cutting & coagulations device with tissue fusion ligasure technology having maryland jaw sealer and divider with wide jaw aperture 13mm and cut length 18.5mm with shaft rotation of 350 degrees and with one step sealing mechanism. should have the manual cutting mechanism. and it should have including 7mm cutting and coag with usfda . , cutting &coagulations device with tissue fusion ligature technology have small jaw tissue sealing system for open procedures vessel sealing instrument with cut length of 14.7 mm, seal length of 16.5mm, jaw angle 28 degrees. should have the manual cutting mechanism.and its should have including 7mm cutting and coag with usfda . , cutting &coagulations device with tissue fusion ligature technology laparoscopic blunt tipped vessel sealer and divider 37 cm long 5mm instrument. wide jaw aperture 14.5 mm with shaft rotation of 180 degrees ; multifunctional laparoscopic device for tissue fusion.and its should have including 7mm cutting and coag with usfda . , cutting &coagulations device with tissue fusion ligasure technology instrument for open surgeries with instrument length between 18-19cm and electrode length between 16-17cm, having 28 degree curved jaw with contoured tip for blunt dissection and having activation both through hand activation and foot activation with a manually controlled cutting mechanism. , cutting &coagulations device with tissue fusion ligasuretechnology have36mm jaw length, 180 degree rotatable instrument with curved blade for large volume tissue. should have the manual cutting mechanism. , cutting &coagulations device with tissue fusion ligasuretechnology have vessel sealing instrument for open surgeries with reusable clamp length between 16-18cm, with 12-14 degree jaw curve.and its should have including 7mm cutting and coag with usfda . , double lumen catheter with kit internal juglar / straight( catheter should be madeup of flexible radiopaque polyurethane with a radiopaque tip, easy visualization in x-ray. accessory should be provided like catheter ,dialator ,introducer, needle 18 g, guidewire with dispencer and injection caps. catheter should be d to have consistent blood flow with laser cut side slot , double lumen catheter with kit internal juglar / straight (catheter should be madeup of flexible radiopaque polyurethane with a radiopaque tip, easy visualization in x-ray. accessory should be provided like catheter ,dialator ,introducer, needle 18 g, guidewire with dispencer and injection caps. catheter should be d to have consistent blood flow with laser cut side slot , double lumen catheter with kit internal juglar / straight (catheter should be madeup of flexible radiopaque polyurethane with a radiopaque tip, easy visualization in x-ray. accessory should be provided like catheter ,dialator ,introducer, needle 18 g, guidewire with dispencer and injection caps. catheter should be d to have consistent blood flow with laser cut side slot , double lumen catheter with kit internal juglar / straight(catheter should be madeup of flexible radiopaque polyurethane with a radiopaque tip, easy visualization in x-ray. accessory should be provided like catheter ,dialator ,introducer, needle 18 g, guidewire with dispencer and injection caps. catheter should be d to have consistent blood flow with laser cut side slot , double lumen catheter with kit internal juglar / straight (catheter should be madeup of flexible radiopaque polyurethane with a radiopaque tip, easy visualization in x-ray. accessory should be provided like catheter ,dialator ,introducer, needle 18 g, guidewire with dispencer and injection caps. catheter should be d to have consistent blood flow with laser cut side slot , double lumen catheter with kit internal juglar / straight (catheter should be madeup of flexible radiopaque polyurethane with a radiopaque tip, easy visualization in x-ray. accessory should be provided like catheter ,dialator ,introducer, needle 18 g, guidewire with dispencer and injection caps. catheter should be d to have consistent blood flow with laser cut side slot , long term double lumen dialysis catheter with kit accessories should be provided ( catheter,pull apart sheath, dialator, tunneling stylet,guide wire j/s,with disppencer and injection caps, symmetrical tip retrograde and antigrade , long term double lumen dialysis catheter with kit accessories should be provided ( catheter,pull apart sheath, dialator, tunneling stylet,guide wire j/s,with disppencer and injection caps, symmetrical tip retrograde and antigrade , long term double lumen dialysis catheter with kit accessories should be provided ( catheter,pull apart sheath, dialator, tunneling stylet,guide wire j/s,with disppencer and injection caps, symmetrical tip retrograde and antigrade , long term double lumen dialysis catheter with kit accessories should be provided ( catheter,pull apart sheath, dialator, tunneling stylet,guide wire j/s,with disppencer and injection caps, symmetrical tip retrograde and antigrade , transperant surgical wound dressing wuth a dimensional hydrocellularpad microbicidle proteciton and anti microbial property , transperant surgical wound dressing wuth a dimensional hydrocellularpad microbicidle proteciton and anti microbial property , transperant surgical wound dressing wuth a dimensional hydrocellularpad microbicidle proteciton and anti microbial property , transperant surgical wound dressing wuth a dimensional hydrocellularpad microbicidle proteciton and anti microbial property , transperant surgical wound dressing wuth a dimensional hydrocellularpad microbicidle proteciton and anti microbial property , non-fibre optic single use adult scope channel width :2.2 mm insertion tube diameter :5.0mm. working length :600 mm bending range :180 degree up & 180 degree down field of view :85 degree or more direction of view : 0 degree (forward view) depth of field :8-50 mm or better minimum ett inner dia :6 mm illumination method :led complete system should be us-fda and european ce certified , multi-vent mask pediatric, multi-vent mask pediatric, air entrainment masks, must be safe, simple delivery of variable oxygen concentrations. each mask to includes color-coded diluters: green for low concentration, white for medium concentration. locking ring to secure flow setting. must include adaptor for high humidity entrainment. complete kit with 7-ft oxygen tubing. manufacturer must be us-fda registered & certified with en/eu iso 13485 & applicable 510k & ce certification. , incentive spirometer incentive spirometer with wide flow range between 200 cc/sec and 1200 cc/sec. must have dual-chamber design to help create constant resistance that lifts ball when patient maintains inspiration equal to selected adjustable flow setting & clearly marked flow settings for easy monitoring. manufacturer must be us-fda registered & certified with en/eu iso 13485 & applicable 510k & ce certification , closed suction catheter mdi port has isolated turbo cleaning chamber for cleaning catheter tip with mdi port.catheter is made up of medical grade silicon material,catheter has zig-zag ports for better suctioning. twin peep seals. available in both endotracheal and tracheostomy version. can be used for 72hr. , closed suction catheter mdi port has isolated turbo cleaning chamber for cleaning catheter tip with mdi port.catheter is made up of medical grade silicon material,catheter has zig-zag ports for better suctioning. twin peep seals. available in both endotracheal and tracheostomy version. can be used for 72hr. , closed suction catheter has isolated turbo cleaning chamber for cleaning catheter tip.catheter is made up of medical grade silicon material,catheter has zig-zag ports for better suctioning. twin peep seals. available in both endotracheal and tracheostomy version.can be used for 72hr. , closed suction catheter has isolated turbo cleaning chamber for cleaning catheter tip.catheter is made up of medical grade silicon material,catheter has zig-zag ports for better suctioning. twin peep seals. available in both endotracheal and tracheostomy version.can be used for 72hr. , fenestrated tracheostomy tube cuffed with 2 inner cannula, inner cannula should reduce the id by 1mm of tracheostomy tube one inner cannula is with five fenestration holes and one is without fenestration , multifocal iol biconvex, single piece designoptic size 6 mm, overall 12-13 mm sizetwo haptics, modified cuv blocking capability360 degrees square edge, sterile packingfoldable lens with insertion via injector, should able to insert in sub 2.8 m.msterile disposable injector with cartridge along with each iolinjector should be of good quality with smooth injection without damaging ioldiopters required +16 to +25 ddiffractive multifocal design with +3 to +4 dioptre additionshould be iso or ce certifiedmanufacturer should be asked to supply samples for approval3 piece feldable 11-28 d , glaucoma drainage implant (valved) with silicon tube adult , glaucoma drainage implant (valved) with silicon tube paediatric , eye sphere implants implantable grade pmma sphere for enclueation and evisceration procedure (pmma) size / sphere diameter - , eye sphere implants implantable grade pmma sphere for enclueation and evisceration procedure (pmma) size / sphere diameter - , eye sphere implants implantable grade pmma sphere for enclueation and evisceration procedure (pmma) size / sphere diameter - , eye sphere implants implantable grade pmma sphere for enclueation and evisceration procedure (pmma) size / sphere diameter - , eye sphere implants implantable grade pmma sphere for enclueation and evisceration procedure (pmma) size / sphere diameter - , eye sphere implants implantable grade silicone sphere for enclueation and evisceration procedure (silicone) size / sphere diameter - , eye sphere implants implantable grade silicone sphere for enclueation and evisceration procedure (silicone) size / sphere diameter - , eye sphere implants implantable grade silicone sphere for enclueation and evisceration procedure (silicone) size / sphere diameter - , eye sphere implants implantable grade silicone sphere for enclueation and evisceration procedure (silicone) size / sphere diameter - , eye sphere implants implantable grade silicone sphere for enclueation and evisceration procedure (silicone) size / sphere diameter - , monocanalicular self retaining silicone stent for canalicular repair - medical graded silicone implant for reconstructing traumatic canalicular lacerations. silicone rod length40mm, silicone rod diameter 0.64 mm , lacrimal intubation set for dcr surgery – bicanalicular lacrimal intubation set comprised of two flexible stainless steel probes attached through a hollow medical tube which is used in conventional dcr procedure. probe length probe diameter silicon tube length silicon tube id silicon tube od - 11 cm 0.60 mm (23g) 30 cm 0.30 mm 0.64 mm , scleral fixiated intraoccular lense having multifoccal toric ,three piece foldable intraoccular lense , vibratory pep therapy device for pead . patients , deliver airflow vibrations to the patients from 5-30 hz expiratory resistance / frequency dial to allow therapy to be adjusted to patientss needs , tracheostomy tube cuffed with sub-glotic suction line and with 2 inner cannula kit, inner cannula should reduce the id by 1mm of tracheostomy tube , dry lithium heparin pre filled abg syringe with air removal filter cap 1ml , dry lithium heparin pre filled abg syringe with air removal filter cap 3ml , central line triple lumen with y needle and nitinol guide wire 8.5 fr with 16cm / 20cm catheter with tecoflex material , central line quadra lumen with y needle and nitinol guide wire 8.5 fr with 15cm / 20cm catheter with tecoflex material , central line quadra lumen with straight needle and nitinol guide wire 8.5 fr with 15cm / 20cm catheter with tecoflex material , peripherally inserted central line for high flow/ power injection sterile made of polyurethane single 55 cm long, 5 french single, double and triple lumen made of polyutherane with guide wire & microintroducer. should deliever infusion at 5 ml/sec rate and have reverse taper hub to provide kink resitance. introducer needle of 21 g. and used for power injection & monitoring cvp . , latex folley balloon catheter , latex folley balloon catheter , ryle’s tube , ryle’s tube , post operative surgical cover dressings hydrofiber dressings with 1.2% w/w impregnated ionic silver & tripple hydrocolloid matrix dressings with broad spectrum bactricidal efficacy with gel forming technology, ce, iso & fda approved , post operative surgical cover dressings hydrofiber dressings with 1.2% w/w impregnated ionic silver & tripple hydrocolloid matrix dressings with broad spectrum bactricidal efficacy with gel forming technology, ce, iso & fda approved , post operative surgical cover dressings hydrofiber dressings with 1.2% w/w impregnated ionic silver & tripple hydrocolloid matrix dressings with broad spectrum bactricidal efficacy with gel forming technology, ce, iso & fda approved , 2 pcs flat base ostomy body fit 60 mm kit 2-piece system base plate with body fit additional elastic adhesive technology (elastic modulus-0.18 n/mm), with 4 ears belt lock. colostomy bag, consists one barrier foil and a oecotex certified water repellent textile neutral grey colour material. triple layer filter with full circle pre filter and three times fold velcro locking drainage. audible click sound locking system with highlighted colour lock button. coupling with wave-shaped locking bag. window on bag for inspection 60mm, elastic tape in semi-circular shape with hydrocolloid adhesive for extra security of base plate. adhesive remover spray consists of hexamethyldisiloxane and cyclonentasiloxane silicone polymers for easy removal of the base plate, alcohol free, sting free 50 ml. cream to maintain peristomal ph value (5.5) of skin contain magnesium citrate, glycerine, petrolatum, citric acid to moisturize and prevent damage to skin 60 ml. non alcoholic ostomy paste for filling and sealing the peristomal skin around the stoma contains polyaliphatic hydrocarbon , water base , gaur gum 60 gm. ostomy powder with natural ingredients such as cmc, guar gum and xanthan gum for peristomal skin excoriation 25 gm. cleanser to clean skin exposed to intestinal secretions consist of isopropyl alcohol, allantoin, natural coconut oil . lubricating deodorant to neutralize odour and provide lubricating effect to ensure content at the bottom not around stoma for easier to empty bag 250 ml. skin barrier for healthy peristomal skin or risk of skin damage due to bady secretions or skin damage already developed consist of polyethylene, plasticizer, polyamide, artificial resin, cmc, sis ( 20cmx20cm), neutral grey colour standerd size belt compatible for bags having 4 ear hooks , 2 pcs flat base ostomy body fit 70 mm kit 2-piece system base plate with body fit additional elastic adhesive technology (elastic modulus-0.18 n/mm), with 4 ears belt lock. colostomy bag, consists one barrier foil and a oecotex certified water repellent textile neutral grey colour material. triple layer filter with full circle pre filter and three times fold velcro locking drainage. audible click sound locking system with highlighted colour lock button. coupling with wave-shaped locking bag. one side transparent for inspection. 70mm. adhesive remover spray consists of hexamethyldisiloxane and cyclonentasiloxane silicone polymers for easy removal of the base plate, alcohol free, sting free 50 ml. cream to maintain peristomal ph value (5.5) of skin contain magnesium citrate, glycerine, petrolatum, citric acid to moisturize and prevent damage to skin 60 ml. non alcoholic ostomy paste for filling and sealing the peristomal skin around the stoma contains polyaliphatic hydrocarbon , water base , gaur gum 60 gm. ostomy powder with natural ingredients such as cmc, guar gum and xanthan gum for peristomal skin excoriation 25 gm. cleanser to clean skin exposed to intestinal secretions consist of isopropyl alcohol, allantoin, natural coconut oil . lubricating deodorant to neutralize odour and provide lubricating effect to ensure content at the bottom not around stoma for easier to empty bag 250 ml. skin barrier for healthy peristomal skin or risk of skin damage due to bady secretions or skin damage already developed consist of polyethylene, plasticizer, polyamide, artificial resin, cmc, sis ( 20cmx20cm), neutral grey colour standerd size belt compatible for bags having 4 ear hooks , 2 pcs convex base ostomy body fit 60 mm kit two-piece system 6 mm aperture convex with integrated flex line base plate. body fit additional elastic adhesive technology (elastic modulus-0.18 n/mm), with 4 ears belt lock.colostomy bag, consists one barrier foil and a oecotex certified water repellent textile neutral grey colour material. triple layer filter with full circle pre filter and three times fold velcro locking drainage. audible click sound locking system with highlighted colour lock button. coupling with wave-shaped locking bag. window on bag for inspection 60mm. adhesive remover spray consists of hexamethyldisiloxane and cyclonentasiloxane silicone polymers for easy removal of the base plate, alcohol free, sting free 50 ml. cream to maintain peristomal ph value (5.5) of skin contain magnesium citrate, glycerine, petrolatum, citric acid to moisturize and prevent damage to skin 60 ml. non alcoholic ostomy paste for filling and sealing the peristomal skin around the stoma contains polyaliphatic hydrocarbon , water base , gaur gum 60 gm. ostomy powder with natural ingredients such as cmc, guar gum and xanthan gum for peristomal skin excoriation 25 gm. cleanser to clean skin exposed to intestinal secretions consist of isopropyl alcohol, allantoin, natural coconut oil . lubricating deodorant to neutralize odour and provide lubricating effect to ensure content at the bottom not around stoma for easier to empty bag 250 ml. skin barrier for healthy peristomal skin or risk of skin damage due to bady secretions or skin damage already developed consist of polyethylene, plasticizer, polyamide, artificial resin, cmc, sis ( 20cm x 20 cm)neutral grey colour standerd size belt compatible for bags having 4 ear hooks , 2 pcs convex base ostomy body fit 70 mm kit two-piece system 6 mm aperture convex with integrated flex line base plate. body fit additional elastic adhesive technology (elastic modulus-0.18 n/mm), with 4 ears belt lock.colostomy bag, consists one barrier foil and a oecotex certified water repellent textile neutral grey colour material. triple layer filter with full circle pre filter and three times fold velcro locking drainage. audible click sound locking system with highlighted colour lock button. coupling with wave-shaped locking bag. window on bag for inspection 70mm. adhesive remover spray consists of hexamethyldisiloxane and cyclonentasiloxane silicone polymers for easy removal of the base plate, alcohol free, sting free 50 ml. cream to maintain peristomal ph value (5.5) of skin contain magnesium citrate, glycerine, petrolatum, citric acid to moisturize and prevent damage to skin 60 ml. non alcoholic ostomy paste for filling and sealing the peristomal skin around the stoma contains polyaliphatic hydrocarbon , water base , gaur gum 60 gm. ostomy powder with natural ingredients such as cmc, guar gum and xanthan gum for peristomal skin excoriation 25 gm. cleanser to clean skin exposed to intestinal secretions consist of isopropyl alcohol, allantoin, natural coconut oil . lubricating deodorant to neutralize odour and provide lubricating effect to ensure content at the bottom not around stoma for easier to empty bag 250 ml. skin barrier for healthy peristomal skin or risk of skin damage due to bady secretions or skin damage already developed consist of polyethylene, plasticizer, polyamide, artificial resin, cmc, sis ( 20cm x 20 cm), neutral grey colour standerd size belt compatible for bags having 4 ear hooks , 1 pcs trasnparent colostomy body fit 60mm kit one-piece colostomy bag- body fit additional elastic adhesive technology (elastic modulus-0.34 n/mm), bag consists one barrier foil and a oecotex certified water repellent textile neutral grey colour material. triple layer filter with full circle pre filter and three times fold velcro locking drainage. one side transparent for inspection 60mm. adhesive remover spray consists of hexamethyldisiloxane and cyclonentasiloxane silicone polymers for easy removal of the base plate, alcohol free, sting free 50 ml. cream to maintain peristomal ph value (5.5) of skin contain magnesium citrate, glycerine, petrolatum, citric acid to moisturize and prevent damage to skin 60 ml. non alcoholic ostomy paste for filling and sealing the peristomal skin around the stoma contains polyaliphatic hydrocarbon , water base , gaur gum 60 gm. ostomy powder with natural ingredients such as cmc, guar gum and xanthan gum for peristomal skin excoriation 25 gm. cleanser to clean skin exposed to intestinal secretions consist of isopropyl alcohol, allantoin, natural coconut oil . lubricating deodorant to neutralize odour and provide lubricating effect to ensure content at the bottom not around stoma for easier to empty bag 250 ml. skin barrier for healthy peristomal skin or risk of skin damage due to bady secretions or skin damage already developed consist of polyethylene, plasticizer, polyamide, artificial resin, cmc, sis ( 20cm x 20 cm) , 2 pcs flat base ostomy body fit bag 60 mm 2-piece system base plate with body fit additional elastic adhesive technology (elastic modulus-0.18 n/mm), with 4 ears belt lock. colostomy bag, consists one barrier foil and a oecotex certified water repellent textile neutral grey colour material. triple layer filter with full circle pre filter and three times fold velcro locking drainage. audible click sound locking system with highlighted colour lock button. coupling with wave-shaped locking bag. window on bag for inspection 60mm , 2 pcs flat base ostomy body fit bag 70 mm 2-piece system base plate with body fit additional elastic adhesive technology (elastic modulus-0.18 n/mm), with 4 ears belt lock. colostomy bag, consists one barrier foil and a oecotex certified water repellent textile neutral grey colour material. triple layer filter with full circle pre filter and three times fold velcro locking drainage. audible click sound locking system with highlighted colour lock button. coupling with wave-shaped locking bag. one side transparent for inspection. 70mm. , 2 pcs convex base ostomy body fit bag 60 mm two-piece system 6 mm aperture convex with integrated flex line base plate. body fit additional elastic adhesive technology (elastic modulus-0.18 n/mm), with 4 ears belt lock.colostomy bag, consists one barrier foil and a oecotex certified water repellent textile neutral grey colour material. triple layer filter with full circle pre filter and three times fold velcro locking drainage. audible click sound locking system with highlighted colour lock button. coupling with wave-shaped locking bag. window on bag for inspection 60mm. , 2 pcs convex base ostomy body fit bag 70 mm two-piece system 6 mm aperture convex with integrated flex line base plate. body fit additional elastic adhesive technology (elastic modulus-0.18 n/mm), with 4 ears belt lock.colostomy bag, consists one barrier foil and a oecotex certified water repellent textile neutral grey colour material. triple layer filter with full circle pre filter and three times fold velcro locking drainage. audible click sound locking system with highlighted colour lock button. coupling with wave-shaped locking bag. window on bag for inspection 70mm. , 1 pcs trasnparent colostomy body fit bag 60mm one-piece colostomy bag- body fit additional elastic adhesive technology (elastic modulus-0.34 n/mm), bag consists one barrier foil and a oecotex certified water repellent textile neutral grey colour material. triple layer filter with full circle pre filter and three times fold velcro locking drainage. one side transparent for inspection 60mm. , non-fibre optic single use large scope channel width :2.8mm insertion tube diameter :5.8 mm. working length :600 mm bending range :180 degree up & 160 degree down field of view :85 degree or more direction of view :0 degree (forward view) depth of field :8 -50 mm or better minimum ett inner dia :7 mm illumination method :led complete system should be us-fda and european ce certified. , antimicrobial silver dresssing sterile non-occulusive wound contact layer consists of silver healing matrix made of polyester mesh impregnated with hydrocolloid particles( cmc) ,petroleum jelly, polymers and silver salts with demonstrated in vitro antibacterial activity upto 7 days, using patented lipido- colloid technology (tlc) , antimicrobial silver dresssing sterile non-occulusive wound contact layer consists of silver healing matrix made of polyester mesh impregnated with hydrocolloid particles( cmc) ,petroleum jelly, polymers and silver salts with demonstrated in vitro antibacterial activity upto 7 days, using patented lipido- colloid technology (tlc) , non-fibre optic single use cysto scope for djr & diagnostic cystoscope it should be capable of easy navigation and fast identification of anatomical landmarks the scopes should be sterile packed one cmos camera and two led light source should be integrated at the distal end minimum length of the scope should be 380 - 400mm working channel should be of 6.5 - 6.6 fr the control lever on handle for the movement of distal tip up & down in a single plane with 210 degree up and 120 degree down , non-fibre optic single use paediatrics scope channel width :1.2mm insertion tube diameter :3.8 mm. working length :600 mm bending range :180 degree up & 180 degree down field of view :85 degree or more direction of view :0 degree (forward view) depth of field :8 -50 mm or better minimum ett inner dia :5 mm illumination method :led complete system should be us-fda and european ce certified. , sterile self adherent with lipido colloid technology sterile self -adherent patented tlc matrix (lipido colloid technology) wound contact layer combined with absorbent polyurethane foam pad , a superabsorbent layer ,a vapour permeable waterproof outer film with soft silicone adhesive border on the edges for atraumatic removal and repositioning of dressing. , sterile self adherent with lipido colloid technology sterile self -adherent patented tlc matrix (lipido colloid technology) wound contact layer combined with absorbent polyurethane foam pad , a superabsorbent layer ,a vapour permeable waterproof outer film with soft silicone adhesive border on the edges for atraumatic removal and repositioning of dressing. , sterile self adherent with lipido colloid technology sterile self -adherent patented tlc matrix (lipido colloid technology) wound contact layer combined with absorbent polyurethane foam pad , a superabsorbent layer ,a vapour permeable waterproof outer film with soft silicone adhesive border on the edges for atraumatic removal and repositioning of dressing. , sterile self adherent with lipido colloid technology sterile self -adherent patented tlc matrix (lipido colloid technology) wound contact layer combined with absorbent polyurethane foam pad , a superabsorbent layer ,a vapour permeable waterproof outer film with soft silicone adhesive border on the edges for atraumatic removal and repositioning of dressing. , sterile self adherent with lipido colloid technology sterile self -adherent patented tlc matrix (lipido colloid technology) wound contact layer combined with absorbent polyurethane foam pad , a superabsorbent layer ,a vapour permeable waterproof outer film with soft silicone adhesive border on the edges for atraumatic removal and repositioning of dressing. , sterile self adherent with lipido colloid technology sterile self -adherent patented tlc matrix (lipido colloid technology) wound contact layer combined with absorbent polyurethane foam pad , a superabsorbent layer ,a vapour permeable waterproof outer film with soft silicone adhesive border on the edges for atraumatic removal and repositioning of dressing. , sterile self adherent with lipido colloid technology sterile self -adherent patented tlc matrix (lipido colloid technology) wound contact layer combined with absorbent polyurethane foam pad , a superabsorbent layer ,a vapour permeable waterproof outer film with soft silicone adhesive border on the edges for atraumatic removal and repositioning of dressing. , 100% polysiloxane based scar management in gel form pure poly siloxane based silicone scar management product in sheet form(we also should mention about the 100% poly siloxane and nylon polyamide mesh) , triple hydrocolloid skin barrier where no cutting is required comprised of pectin, gelatin and sodium carboxy methyl cellulose,elastomeric polymers extending turtlenecking effect and rebounding memory technology with audible click and flexible tape collar. , triple hydrocolloid skin barrier where no cutting is required comprised of pectin, gelatin and sodium carboxy methyl cellulose,elastomeric polymers extending turtlenecking effect and rebounding memory technology with audible click and flexible tape collar. , triple hydrocolloid skin barrier where no cutting is required comprised of pectin, gelatin and sodium carboxy methyl cellulose,elastomeric polymers extending turtlenecking effect and rebounding memory technology with audible click and flexible tape collar. , drainable pouch 12, with filter embeded & 2 sided hydrophobic comfort panel standard, opaque with integrated dotted velcro tail closure , drainable pouch 12, with filter embeded & 2 sided hydrophobic comfort panel standard, opaque with integrated dotted velcro tail closure , drainable pouch 12, with filter embeded & 2 sided hydrophobic comfort panel standard, opaque with integrated dotted velcro tail closure , sulu stepped cartridges for variable tissue application , fixed anvil , different leg length staples in same cartridge , inbuilt knife ,size 60 mm inner to outer side 3.0,3.5 and 4.0 mm , purple colour code, usfda approved , titanium total ossocular replacement prosthesis (torp) , titanium partial ossocular replacement prosthesis (porp) , piston titanium (0.4mm ) diameter , piston titanium (0.4mm ) diameter , piston titanium (0.4mm) diameter , piston titanium (0.4mm ) diameter , piston titanium (0.6mm) diameter , piston titanium (0.6mm) diameter , piston titanium (0.6mm) diameter , piston titanium (0.6mm) diameter , piston titanium - teflon mix (0.4mm ) diameter , piston titanium - teflon mix (0.4mm ) diameter , piston titanium - teflon mix (0.4mm ) diameter , piston titanium - teflon mix (0.4mm ) diameter , piston titanium - teflon mix (0.6mm) diameter , piston titanium - teflon mix (0.6mm) diameter , piston titanium - teflon mix (0.6mm) diameter , piston titanium - teflon mix (0.6mm) diameter , piston teflon (ptfe) (0.4mm ) diameter , piston teflon (ptfe) (0.4mm ) diameter , piston teflon (ptfe) (0.4mm) diameter , piston teflon (ptfe) (0.4mm ) diameter , piston teflon (ptfe) (0.6mm) diameter , piston teflon (ptfe) (0.6mm) diameter , piston teflon (ptfe) (0.6mm) diameter , piston teflon (ptfe) (0.6mm) diameter , burr tips (tungeston carbide material) round tip (70 mm length) - cutting 0.5 mm , burr tips (tungeston carbide material) round tip (70 mm length) - cutting 0.6 mm , burr tips (tungeston carbide material) round tip (70 mm length) - cutting /0.8 mm , burr tips (tungeston carbide material) round tip (70 mm length) - cutting 1.6 mm , burr tips (tungeston carbide material) round tip (70 mm length) - cutting 2.3 mm , burr tips (tungeston carbide material) round tip (70 mm length) - cutting 2.8 mm , burr tips (tungeston carbide material) round tip (70 mm length) - cutting 3 mm , burr tips (tungeston carbide material) round tip (70 mm length) - cutting 3.5 mm , burr tips (tungeston carbide material) round tip (70 mm length) - cutting 4 mm , burr tips (tungeston carbide material) round tip (70 mm length) - cutting 5 mm , burr tips (tungeston carbide material) round tip (70 mm length) - diamond 0.5 mm , burr tips (tungeston carbide material) round tip (70 mm length) - diamond 0.6 mm , burr tips (tungeston carbide material) round tip (70 mm length) - diamond /0.8 mm , burr tips (tungeston carbide material) round tip (70 mm length) - diamond 1.6 mm , burr tips (tungeston carbide material) round tip (70 mm length) - diamond 2.3 mm , burr tips (tungeston carbide material) round tip (70 mm length) - diamond 2.8 mm , burr tips (tungeston carbide material) round tip (70 mm length) - diamond 3 mm , burr tips (tungeston carbide material) round tip (70 mm length) - diamond 3.5 mm , burr tips (tungeston carbide material) round tip (70 mm length) - diamond 4 mm , burr tips (tungeston carbide material) round tip (70 mm length) - diamond 5 mm , burr tips (tungeston carbide material) round tip - fissure burr 70 mm to 95 mm length 1 mm , burr tips (tungeston carbide material) round tip - fissure burr 70 mm to 95 mm length 3, mm , burr tips (tungeston carbide material) round tip - fissure burr 70 mm to 95 mm length 5 mm , sialestic sheet 55x75 mm and thickness 0.5 mm , ear pack/wick (12x24 mm length) , t-tube (silicone) 9 mm length , nasal haemostatic sponge pack with out airway 8 inch , nasal haemostatic sponge pack with out airway 10 inch , nasal haemostatic sponge pack (with airway) 8 inch , tracheostomy tube (pvc material) double lumen 3.5 -8mm all size , tracheostomy tube (pvc material) fenestrated 3.5 -8mm all size , femoral sheath including pott’s needle, j tipped wire, dilator and sheath all sizes , femoral sheath including pott’s needle, j tipped wire, dilator and sheath all sizes , femoral sheath including pott’s needle, j tipped wire, dilator and sheath all sizes , femoral sheath including pott’s needle, j tipped wire, dilator and sheath all sizes , femoral sheath including pott’s needle, j tipped wire, dilator and sheath all sizes , diagnostic catheter ar 1 aka amplatz right , diagnostic catheter ar 1 aka amplatz right , diagnostic catheter vert angled tip 125cm , diagnostic catheter sim 1 aka simmon’s , diagnostic catheter sim 1 aka simmon’s , diagnostic catheter sim 2 aka simmon , diagnostic catheter sim 3 aka simmon , diagnostic catheter h 1 aka headhunter , diagnostic catheter pigtail , guide wire hydrophilic coated angled tip soft regular standard , guide wire hydrophilic coated angled tip extra stiff , guiding catheter braided guiding catheter in various shapes , guiding catheter braided guiding catheter in various shapes , guiding catheter braided guiding catheter in various shapes , guiding catheter braided guiding catheter in various shapes , guiding catheter braided guiding catheter in various shapes , guiding catheter braided guiding catheter in various shapes , guiding catheter balloon tipped guiding catheter size , distal access catheter , distal access catheter , intracranial support catheter with flat soft distal segment , intracranial support catheter with flat soft distal segment , flexometlic tube 3-8.5 with stylet reinforce et tube with wiring from tip to end it should be approved by *us fda , act tubes us fda + ce/ dgci approved· disposable act tubes compatible with existing medtronic machines at smsh· should meet highest medical industrial standards· quality certification should be provided from authorized agencies. , high – presure injector lines us fda + ce/ dgci pproved· should be available in various lengths· should have male and female luer locks· should be transparent and kink resistant· should be able to take high pressure of angiographic injections , disposable transducers for invasive pressure monitoring compatible with available system in cath lab in smsh us fda + ce/ dgci approved• disposable transducers for invasive pressure monitoring• should be compatible with available system in cath lab (iabp – data scope & cath lab transducer) and iccu at smsh• should meet highest medical industrial standards• quality certification should be provided form authorized agencies , renal double curve catheter us fda + ce/ dgci approved· , simmons/ sidewinder catheter us fda + ce/ dgci approved· , vertebral catheter , coeliac axis catheter us fda + ce/ dgci approved· , shepherd’s hook catheter us fda + ce/ dgci approved· , vtk diagnostic catheter us fda + ce/ dgci approved· , angiographic sizing pigtail catheter 5fr us fda + ce/ dgci approved , angiographic sizing pigtail catheter 6fr us fda + ce/ dgci approved , angiographic sizing pigtail catheter 7fr us fda + ce/ dgci approved , balloon inflation catheter for brto usa/fda/ce approved 9/10 f 0.035 compatible ,length100/120 cm ,max volume 30/40 cc , dialyzer (dialyzer should be synthetic membran(poly sulfon/poly ethresulfon) , dialyzer (dialyzer should be synthetic membran(poly sulfon/poly ethresulfon) , dialyzer (dialyzer should be synthetic membran(poly sulfon/poly ethresulfon) , dialyzer (dialyzer should be synthetic membran(poly sulfon/poly ethresulfon) , pediatric dialyzer (dialyzer should be synthetic membran(poly sulfon/poly ethresulfon) , pediatric dialyzer (dialyzer should be synthetic membran(poly sulfon/poly ethresulfon) , multirate elastomeric disposable infusion pump with air vent blue end cap for air bubble removal and with two micro iv filters in 100 ml & 275 ml with flow rate from 1-7/hr and 2- 14ml/hr , single rate elastomeric disposable infusion pump with air vent blue end cap for air bubble removal and with two micro iv filters in 100 ml & 275 ml with flow rate of 2,5,8,10ml/hr , pct kit with griggs forceps and with subglotic suction line tracheostomy tube with usfda/european ce , pct kit without griggs forceps and with subglotic suction line tracheostomy tube with usfda/european ce , double lumen closed suction set for et and tt , with mdi adopter , trach wedge , swiel connector and with reservoir , et tube with yellow subglotic suction line with inverted and soft seal cuff. with usfda/european ce , tt tube with yellow sub glotic suction line with inverted and soft seal cuff. with usfda/european ce , catheter stabilization device sterile latex free sutureless with sliding post , titanium maxillofacial fracture fixation miniplate 2.5 mm , titanium maxillofacial fracture fixation miniplate 2.0 mm , titanium maxillofacial fracture fixation miniplate 1.5 mm , titanium maxillofacial fracture fixation miniplate 1.5 mm c plate , titanium maxillofacial fracture fixation miniplate 2.5 mm l plate right and left side , titanium maxillofacial fracture fixation miniplate 2.0 mm l plate right and left side , titanium maxillofacial fracture fixation screws 1.5 mm , titanium maxillofacial fracture fixation screws 2.0 mm , titanium maxillofacial fracture fixation screws 2.5 mm , nitrile gloves non sterlite powder free minimum 280mm length white/blue color, polyacrylate coated nitrile examination glove absence of residual accelerator - zinc dibutyl dithiocarbamate a) minimum puncture resistance force 6.86n b) absence of common allergens (micro-gram/g)– hev b 1, hev b 3, hev b 5 & hev b 6.02 , nitrile gloves non sterlite powder free minimum 280mm length white/blue color, polyacrylate coated nitrile examination glove absence of residual accelerator - zinc dibutyl dithiocarbamate a) minimum puncture resistance force 6.86n b) absence of common allergens (micro-gram/g)– hev b 1, hev b 3, hev b 5 & hev b 6.02 , absorbable gelatin sponge ip 66, size 80(+-10) mm x 50 mm x 10 mm should be sterlized. , absorbent cotton wool ip 500 gm , asepto syringe with transparent bulb sterile, 60 ml , blood administration set / blood transfusion set • sharp and easy piercing spike suitable for blood bags and standard blood containers • transparent cylindrical drip chamber with filter.filter size should be 200+20 micrometer. • 150 cm long smooth kink resistant tubing • efficient roller clamp to control and adjust the transfusion rate • should conform to is 9824(part 3):1996 , disposable sterile surgical rubber gloves size 6 ½ inches • made of natural rubber latex, powdered, without tear, properly folded in a paper • free of holes, with acceptable quality level (aql) of 1.5 or less • tensile strength as per en 455-2 • powder should be non-allergenic • should conform to is 13422 • isi marked / ce certified / fda approved , disposable sterile surgical rubber gloves size 6 ½ inches • made of natural rubber latex, powder free (polymer /silicon coated), without tear, properly folded in a paper • free of holes, with acceptable quality level (aql) of 1.5 or less • tensile strength as per en 455-2 • should conform to is 13422 isi marked / ce certified / fda approved (ce certification / fda approval for item is mandatory for importer firms, that cannot avail is standards) , disposable sterile surgical rubber gloves size 7 inches • made of natural rubber latex, powdered,,without tear, properly folded in a paper • free of holes, with acceptable quality level (aql) of 1.5 or less • tensile strength as per en 455-2 • powder should be non-allergenic • should conform to is 13422 • isi marked / ce certified / fda approved , disposable sterile surgical rubber gloves size 7 inches • made of natural rubber latex, powder free (polymer /silicon coated), without tear, properly folded in a paper • free of holes, with acceptable quality level (aql) of 1.5 or less • tensile strength as per en 455-2 • should conform to is 13422 isi marked / ce certified / fda approved (ce certification / fda approval for item is mandatory for importer firms, that cannot avail is standards) , disposable sterile surgical rubber gloves size 7½ inches • made of natural rubber latex, powdered, without tear, properly folded in a paper • free of holes, with acceptable quality level (aql) of 1.5 or less • tensile strength as per en 455-2 • powder should be non-allergenic • should conform to is 13422 • isi marked / ce certified / fda approved , disposable sterile surgical rubber gloves size 7 ½ inches • made of natural rubber latex, powder free (polymer /silicon coated), without tear, properly folded in a paper • free of holes, with acceptable quality level (aql) of 1.5 or less • tensile strength as per en 455-2 • should conform to is 13422 isi marked / ce certified / fda approved (ce certification / fda approval for item is mandatory for importer firms, that cannot avail is standards , suction catheter, sterile. size: fg 5 (for use in respiratory tract) • soft, kink resistant tubing • rounded open tip with lateral eye • colour coded universal funnel connector for safe connection to standard suction equipment • length 50 cm (min.) • should conform to is0 8836:2014 , suction catheter, sterile. size: fg 6 (for use in respiratory tract) • soft, kink resistant tubing • rounded open tip with lateral eye • colour coded universal funnel connector for safe connection to standard suction equipment • length 50 cm (min.) • should conform to is0 8836:2014 , suction catheter, sterile. size: fg 8 (for use in respiratory tract) • soft, kink resistant tubing • rounded open tip with lateral eye • colour coded universal funnel connector for safe connection to standard suction equipment • length 50 cm (min.) • should conform to is0 8836:2014 , suction catheter, sterile. size: fg 10 (for use in respiratory tract) • soft, kink resistant tubing • rounded open tip with lateral eye • colour coded universal funnel connector for safe connection to standard suction equipment • length 50 cm (min.) • should conform to is0 8836:2014 , suction catheter, sterile. size: fg 12 (for use in respiratory tract) • soft, kink resistant tubing • rounded open tip with lateral eye • colour coded universal funnel connector for safe connection to standard suction equipment • length 50 cm (min.) • should conform to is0 8836:2014 , suction catheter, sterile. size: fg 14 (for use in respiratory tract) • soft, kink resistant tubing • rounded open tip with lateral eye • colour coded universal funnel connector for safe connection to standard suction equipment • length 50 cm (min.) • should conform to is0 8836:2014 , suction catheter, sterile. size: fg 16 (for use in respiratory tract) • soft, kink resistant tubing • rounded open tip with lateral eye • colour coded universal funnel connector for safe connection to standard suction equipment • length 50 cm (min.) • should conform to is0 8836:2014 , suction catheter, sterile. size: fg 18 (for use in respiratory tract) • soft, kink resistant tubing • rounded open tip with lateral eye • colour coded universal funnel connector for safe connection to standard suction equipment • length 50 cm (min.) • should conform to is0 8836:2014 , suction catheter, sterile. size: fg 20 (for use in respiratory tract) • soft, kink resistant tubing • rounded open tip with lateral eye • colour coded universal funnel connector for safe connection to standard suction equipment • length 50 cm (min.) • should conform to is0 8836:2014 , suction catheter, sterile. size: fg 22 (for use in respiratory tract) • soft, kink resistant tubing • rounded open tip with lateral eye • colour coded universal funnel connector for safe connection to standard suction equipment • length 50 cm (min.) • should conform to is0 8836:2014 , sterile catheter, single use, for urinary drainage (foley balloon catheter), 2 way, size 8 fg • made of silicone elastomer bonded with latex • should have hard plastic valve • smooth distal end with smooth eyes for atraumatic intubation • symmetrical foley balloon • balloon capacity 3- 5 ml • should conform to is 11497 • color coding marking to identify size • length, wall thickness and balloon capacity should be mentioned as per is 11497. • specification for b,c,d,e,f,g should be mentioned as per is 11497 for particular size , sterile catheter, single use, for urinary drainage (foley balloon catheter), 2 way, size10 fg • made of silicone elastomer bonded with latex • should have hard plastic valve • smooth distal end with smooth eyes for atraumatic intubation • symmetrical foley balloon • balloon capacity 3- 5 ml • should conform to is 11497 • color coding marking to identify size • length, wall thickness and balloon capacity should be mentioned as per is 11497. • specification for b,c,d,e,f,g should be mentioned as per is11497 for particular size , sterile catheter, single use, for urinary drainage (foley balloon catheter), 2 way, size16 fg • made of silicone elastomer bonded with latex • should have hard plastic valve • smooth distal end with smooth eyes for atraumatic intubation • symmetrical foley balloon • balloon capacity 30 ± 1ml • should conform to is 11497 • color coding marking to identify size • length, wall thickness and balloon capacity should be mentioned as per is 11497. • specification for b,c,d,e,f,g should be mentioned as per is11497 for particular size , sterile catheter, single use, for urinary drainage (foley balloon catheter), 2 way, size18 fg • made of silicone elastomer bonded with latex • should have hard plastic valve • smooth distal end with smooth eyes for atraumatic intubation • symmetrical foley balloon • balloon capacity 30 ± 1 ml • should conform to is 11497 • color coding marking to identify size • length, wall thickness and balloon capacity should be mentioned as per is 11497. • specification for b,c,d,e,f,g should be mentioned as per is11497 for particular size , sterile catheter, single use, for urinary drainage (foley balloon catheter), 2 way, size20 fg • made of silicone elastomer bonded with latex • should have hard plastic valve • smooth distal end with smooth eyes for atraumatic intubation • symmetrical foley balloon • balloon capacity 30 ± 1 ml • should conform to is 11497 • color coding marking to identify size • length, wall thickness and balloon capacity should be mentioned as per is 11497. • specification for b,c,d,e,f,g should be mentioned as per is11497 for particular size , sterile catheter, single use, for urinary drainage (foley balloon catheter), 2 way, size22 fg • made of silicone elastomer bonded with latex • should have hard plastic valve • smooth distal end with smooth eyes for atraumatic intubation • symmetrical foley balloon • balloon capacity 30 ± 1 ml • should conform to is 11497 • color coding marking to identify size • length, wall thickness and balloon capacity should be mentioned as per is 11497. • specification for b,c,d,e,f,g should be mentioned as per is11497 for particular size , sterile catheter, single use, for urinary drainage (foley balloon catheter), 2 way, size 24 fg • made of silicone elastomer bonded with latex • should have hard plastic valve • smooth distal end with smooth eyes for atraumatic intubation • symmetrical foley balloon • balloon capacity 30 ± 1 ml • should conform to is 11497 • color coding marking to identify size • length, wall thickness and balloon capacity should be mentioned as per is 11497. • specification for b,c,d,e,f,g should be mentioned as per is11497 for particular size , infant feeding tube size:10fg length 50 cm (min.) • two lateral eyes at distal end • soft, kink resistant non-toxic pvc tubing, non irritant to delicate mucosa • with female flexible mount with in-built closure • radio opaque line • sterile , infant feeding tube size:8fg, length 50 cm (min.) • two lateral eyes at distal end • soft, kink resistant non-toxic pvc tubing, non irritant to delicate mucosa • with female flexible mount with in-built closure • radio opaque line • sterile , infant feeding tube size:5fg length 50 cm (min.) • two lateral eyes at distal end • soft, kink resistant non-toxic pvc tubing, non irritant to delicate mucosa • with female flexible mount with in-built closure • radio opaque line • sterile , sterile disposable perfusion set with airway and needle (adult use) • for gravity feed only • sharp and easy piercing spike with air vent • transparent and flexible drip chamber • 150 cm long smooth kink resistant tubing • self sealing latex bulb which will also act as an port for extra medication • efficient roller clamp to control and adjust the fluid rate • 21 g needle • should conform to is 12655 -4 standard , sterile disposable perfusion set (infusion set) with airway and needle (paediatric use) • burette type measured volume chamber of 100 ml • drop size of approx 60 drops per ml • injection port,latexfree, for intermittent medication. • floating auto shut off valve (latex free) in burette. • soft and kink resistant pvc tubing. • roller controller for flow control • tube length 150 cm • 23g needle • should conform to iso 8536-5 , sterile disposable infusion set with microdrip (i.v.) • microdrip infusion set with drop size reduced to approx 60 drops per ml • sharp and easy piercing spike • transparent and flexible drip chamber • 150 cm long smooth kink resistant tubing • efficient roller clamp to control and adjust the fluid rate • should conform to is 12655 - 4 standard , insulin syringe ( 40 units) with (fixed) 30 g needle shall conform to is 12227 , sterile disposable (single use) teflon / ptfe i.v. cannula with integrated 3 way stop cock. size 16g • should be packed in transparent, single blister pack. • should conform to is 10555 standard , sterile disposable (single use teflon / ptfe i.v. cannula with integrated 3 way stop cock. ) size 18g • should be packed in transparent, single blister pack. • should conform to is 10555 standard , sterile disposable (single use) teflon / ptfe i.v. cannula with integrated 3 way stop cock. size 20g • should be packed in transparent, single blister pack. • should conform to is 10555 standard , sterile disposable (single use) teflon / ptfe i.v. cannula with integrated 3 way stop cock. size 22g • should be packed in transparent, single blister pack. • should conform to is 10555 standard , sterile disposable (single use) teflon/ ptfe i.v. cannula without port. size 24g • suitable for paediatric & neonatal use • should be packed in transparent, single blister pack. • should conform to is 10555 standard , mucus extractor sterile • clear transparent container • antibacterial filter • soft, kink resistant pvc tubing • tube size 10 fg; length 40 cm (min.) • capacity 25 ml , nasal oxygen cannula (set), twin bore (accessory for compressed air breathing) all sizes (adult) • soft and kink resistant pvc tubing • multichannel / star lumen to preventing accidental kinking • twin bores should ensure equal volume of oxygen to both air passages • connector for easy connection to the oxygen source • tube length 200 cm , nasal oxygen cannula (set), twin bore (accessory for compressed air breathing) all sizes (pediatrics) • soft and kink resistant pvc tubing • multichannel / star lumen to preventing accidental kinking • twin bores should ensure equal volume of oxygen to both air passages • connector for easy connection to the oxygen source • tube length 200 cm , paper adhesive plaster 1 x 9.0 mts (with cutter) non woven adhesive tape,hypoallergic,should have some stretch bonding , paper adhesive plaster 2 x 9.0 mts (with cutter) non woven adhesive tape hypoallergic, should have some stretch bonding , paper adhesive plaster 3 x 9.0 mts (with cutter) non woven adhesive tape hypoallergic, should have some stretch bonding , plaster of paris bandages 15cm x 2.7mts / roll should conform to schedule f(ii) of drug and cosmetic act 1940 , plaster of paris bandages 10cm x 2.7mts / roll should conform to schedule f(ii) of drug and cosmetic act 1940 , ryles tube / nasogastric tube (p.v.c.) with radio opaque lining. size: 10 • soft, kink resistant pvc tubing for atraumatic intubation • closed distal end should be coned with radio opaque material for accurate intubation • four lateral eyes for greater efficiency • radio opaque line • marking at 50, 60, 70 cm from tip • colour coded funnel • with luer connector / closure • length 105 cm , ryles tube / nasogastric tube (p.v.c.) with radio opaque lining. size: 12 • soft, kink resistant pvc tubing for atraumatic intubation • closed distal end should be coned with radio opaque material for accurate intubation • four lateral eyes for greater efficiency • radio opaque line • marking at 50, 60, 70 cm from tip • colour coded funnel • with luer connector / closure • length 105 cm , ryles tube / nasogastric tube (p.v.c.) with radio opaque lining. size: 14 • soft, kink resistant pvc tubing for atraumatic intubation • closed distal end should be coned with radio opaque material for accurate intubation • four lateral eyes for greater efficiency • radio opaque line • marking at 50, 60, 70 cm from tip • colour coded funnel • with luer connector / closure • length 105 cm , ryles tube / nasogastric tube (p.v.c.) with radio opaque lining. size: 16 • soft, kink resistant pvc tubing for atraumatic intubation • closed distal end should be coned with radio opaque material for accurate intubation • four lateral eyes for greater efficiency • radio opaque line • marking at 50, 60, 70 cm from tip • colour coded funnel • with luer connector / closure • length 105 cm , ryles tube / nasogastric tube (p.v.c.) with radio opaque lining. size: 18 • soft, kink resistant pvc tubing for atraumatic intubation • closed distal end should be coned with radio opaque material for accurate intubation • four lateral eyes for greater efficiency • radio opaque line • marking at 50, 60, 70 cm from tip • colour coded funnel • with luer connector / closure • length 105 cm , scalp vein set (disposable): size 18g • butterfly shaped wings for easy handling and attachment with skin. colour coded • needle should be bevelled, siliconised and should ensure atraumatic cannulation • female luer fitting at one end • soft, kink resistant, non-toxic, non irritant tube • sterile , scalp vein set (disposable): size 20g • butterfly shaped wings for easy handling and attachment with skin. colour coded • needle should be bevelled, siliconised and should ensure atraumatic cannulation • female luer fitting at one end • soft, kink resistant, non-toxic, non irritant tube • sterile , scalp vein set (disposable): size 22g • butterfly shaped wings for easy handling and attachment with skin. colour coded • needle should be bevelled, siliconised and should ensure atraumatic cannulation • female luer fitting at one end • soft, kink resistant, non-toxic, non irritant tube • sterile , scalp vein set (disposable): size 24g • butterfly shaped wings for easy handling and attachment with skin. colour coded • needle should be bevelled, siliconised and should ensure atraumatic cannulation • female luer fitting at one end • soft, kink resistant, non-toxic, non irritant tube • sterile , sterile hypodermic syringe with needle attached, 24g, single use - 2 ml • clear transparent chamber • prominent graduation • inert material gasket at the piston to minimise friction during movement & prevent leakage and back flow • sharp needle ensuring minimum trauma during penetration • shall conform to is 12050 • packing: needle should be attached with the syringe and packed in unit ribbon pack • the words destroy after single use or equivalent should be written on unit container , sterile hypodermic syringe with needle attached, 24g, single use - 5 ml • clear transparent chamber • prominent graduation • inert material gasket at the piston to minimise friction during movement & prevent leakage and back flow • sharp needle ensuring minimum trauma during penetration • shall conform to is 12050 • packing: needle should be attached with the syringe and packed in unit ribbon pack • the words destroy after single use or equivalent should be written on unit container. , sterile hypodermic syringe with needle attached, 22g, single use - 10 ml • clear transparent chamber • prominent graduation • inert material gasket at the piston to minimise friction during movement & prevent leakage and back flow • sharp needle ensuring minimum trauma during penetration • shall conform to is 12050 • packing: needle should be attached with the syringe and packed in unit ribbon pack • the words destroy after single use or equivalent should be written on unit container. , sterile hypodermic syringe with needle attached, 22g, single use - 20 ml • clear transparent chamber • prominent graduation • inert material gasket at the piston to minimise friction during movement & prevent leakage and back flow • sharp needle ensuring minimum trauma during penetration • shall conform to is 12050 • packing: needle should be attached with the syringe and packed in unit ribbon pack • the words destroy after single use or equivalent should be written on unit container. , surgical blade sterile, size 11 • single peel pack in metal foil • the tip of the blade shall be well defined, central and sharp. there shall be no waviness, jags, feathers, nicks, or other defects on the cutting edge. the surfaces of the blade shall be smooth and free from tool marks and any sign of corrosion. • should conform to is 3319 , surgical blade sterile, size 15 • single peel pack in metal foil • the tip of the blade shall be well defined, central and sharp. there shall be no waviness, jags, feathers, nicks, or other defects on the cutting edge. the surfaces of the blade shall be smooth and free from tool marks and any sign of corrosion. • should conform to is 3319 , surgical blade sterile, size 22 • single peel pack in metal foil • the tip of the blade shall be well defined, central and sharp. there shall be no waviness, jags, feathers, nicks, or other defects on the cutting edge. the surfaces of the blade shall be smooth and free from tool marks and any sign of corrosion. • should conform to is 3319 , suture needles curved 1/2 circle round body assorted size 11-15 • it should be mentioned whether needle is pointed or blunt with type of its point. • type of eye of the needle should be mentioned. • should conform to is-9165 , suture needles curved 1/2 circle round body assorted size 1-5 • it should be mentioned whether needle is pointed or blunt with type of its point. • type of eye of the needle should be mentioned. • should conform to is-9165 , suture needles curved 1/2 circle round body assorted size 16-20 • it should be mentioned whether needle is pointed or blunt with type of its point. • type of eye of the needle should be mentioned. • should conform to is-9165 , suture needles curved 1/2 circle round body assorted size 6-10 • it should be mentioned whether needle is pointed or blunt with type of its point. • type of eye of the needle should be mentioned. • should conform to is-9165 , suture needles curved and cutting 1/2 circle cutting size 6-10 • it should be mentioned whether needle is pointed or blunt with type of its point. • type of eye of the needle should be mentioned. • should conform to is-9165 , suture needles curved and cutting 1/2 circle size 11-15 • it should be mentioned whether needle is pointed or blunt with type of its point. • type of eye of the needle should be mentioned. • should conform to is-9165 , suture needles curved and cutting 1/2 circle size 16-20 • it should be mentioned whether needle is pointed or blunt with type of its point. • type of eye of the needle should be mentioned. • should conform to is-9165 , suture needles curved and cutting size 1-5 • it should be mentioned whether needle is pointed or blunt with type of its point. • type of eye of the needle should be mentioned. • should conform to is-9165 , sterile disposable spinal needle for single use 22g x 3 ½ inch • clear / transparent hub • sharp tip which should ensure minimal puncture trauma , sterile disposable spinal needle for single use 25g x 3 ½ inch • clear / transparent hub • sharp tip which should ensure minimal puncture trauma , urine collecting bag, disposable 2000 ml • transparent sheet • kink resistant flexible tubing not less than 90 cm in length • should have non-return valve • top drainage outlet • graduated bag • moulded handle for easy handling , double j stent, sterile, both ends open - size 4f, length 16 cm • radio opaque • should be of inert material, non- irritant to tissue , double j stent, sterile, both ends open, size 5f, length 20 cm • radio opaque • should be of inert material, non- irritant to tissue , double j stent, sterile, one end closed - size 4f, length 16 cm • radio opaque • should be of inert material, non- irritant to tissue , double j stent, sterile, one end closed, size 5f, length 20 cm • radio opaque • should be of inert material, non- irritant to tissue , endotracheal tube, plain - size 2.5mm • transparent • standard 15 mm connector at proximal end • radio-opaque line throughout the length • tip suitable for nasal and oral intubation • single use, sterile , endotracheal tube, plain - size 3mm • transparent • standard 15 mm connector at proximal end • radio-opaque line throughout the length • tip suitable for nasal and oral intubation • single use, sterile , endotracheal tube, plain - size 3.5mm • transparent • standard 15 mm connector at proximal end • radio-opaque line throughout the length • tip suitable for nasal and oral intubation • single use, sterile , endotracheal tube, plain - size 4mm • transparent • standard 15 mm connector at proximal end • radio-opaque line throughout the length • tip suitable for nasal and oral intubation • single use, sterile , endotracheal tube, plain - size 4.5mm • transparent • standard 15 mm connector at proximal end • radio-opaque line throughout the length • tip suitable for nasal and oral intubation • single use, sterile , endotracheal tube, plain - size 5mm • transparent • standard 15 mm connector at proximal end • radio-opaque line throughout the length • tip suitable for nasal and oral intubation • single use, sterile , endotracheal tube, plain - size 5.5mm • transparent • standard 15 mm connector at proximal end • radio-opaque line throughout the length • tip suitable for nasal and oral intubation • single use, sterile , endotracheal tube, plain with radio-opaque line, sterile, single use - size 6mm • transparent • standard 15 mm connector at proximal end • radio-opaque line throughout the length • tip suitable for nasal and oral intubation • single use, sterile , endotracheal tube, plain - size 6.5mm • transparent • standard 15 mm connector at proximal end • radio-opaque line throughout the length • tip suitable for nasal and oral intubation • single use, sterile , endotracheal tube, plain - size 7mm • transparent • standard 15 mm connector at proximal end • radio-opaque line throughout the length • tip suitable for nasal and oral intubation • single use, sterile , endotracheal tube, plain - size 7.5mm • transparent • standard 15 mm connector at proximal end • radio-opaque line throughout the length • tip suitable for nasal and oral intubation • single use, sterile , endotracheal tube, plain - size 8mm • transparent • standard 15 mm connector at proximal end • radio-opaque line throughout the length • tip suitable for nasal and oral intubation • single use, sterile , endotracheal tube, plain - size 8.5mm • transparent • standard 15 mm connector at proximal end • radio-opaque line throughout the length • tip suitable for nasal and oral intubation • single use, sterile , endotracheal tube, cuffed - size 4mm • soft cuff towards the distal end • kink resistant inflation tube • murphy eye at distal end with polished smoothness • radio-opaque line • standard 15 mm connector • sterile, single use • curved shaped blister pack – suiting the shape of product , endotracheal tube, cuff - size 4.5mm • soft cuff towards the distal end • kink resistant inflation tube • murphy eye at distal end with polished smoothness • radio-opaque line • standard 15 mm connector • sterile, single use • curved shaped blister pack – suiting the shape of product , endotracheal tube, cuff - size 5mm • soft cuff towards the distal end • kink resistant inflation tube • murphy eye at distal end with polished smoothness • radio-opaque line • standard 15 mm connector • sterile, single use • curved shaped blister pack – suiting the shape of product , endotracheal tube, cuff - size 6mm • soft cuff towards the distal end • kink resistant inflation tube • murphy eye at distal end with polished smoothness • radio-opaque line • standard 15 mm connector • sterile, single use • curved shaped blister pack – suiting the shape of product , endotracheal tube, cuff - size 6.5mm • soft cuff towards the distal end • kink resistant inflation tube • murphy eye at distal end with polished smoothness • radio-opaque line • standard 15 mm connector • sterile, single use • curved shaped blister pack – suiting the shape of product , endotracheal tube, cuff - size 7mm • soft cuff towards the distal end • kink resistant inflation tube • murphy eye at distal end with polished smoothness • radio-opaque line • standard 15 mm connector • sterile, single use • curved shaped blister pack – suiting the shape of product , endotracheal tube, cuff - size 7.5 • soft cuff towards the distal end • kink resistant inflation tube • murphy eye at distal end with polished smoothness • radio-opaque line • standard 15 mm connector • sterile, single use • curved shaped blister pack – suiting the shape of product , endotracheal tube, cuff - size 8 • soft cuff towards the distal end • kink resistant inflation tube • murphy eye at distal end with polished smoothness • radio-opaque line • standard 15 mm connector • sterile, single use • curved shaped blister pack – suiting the shape of product , endotracheal tube, cuff - size 8.5 • soft cuff towards the distal end • kink resistant inflation tube • murphy eye at distal end with polished smoothness • radio-opaque line • standard 15 mm connector • sterile, single use • curved shaped blister pack – suiting the shape of product , endotracheal tube, cuff - size 9 • soft cuff towards the distal end • kink resistant inflation tube • murphy eye at distal end with polished smoothness • radio-opaque line • standard 15 mm connector • sterile, single use • curved shaped blister pack – suiting the shape of product , tracheostomy tube (pvc), plain, sterile, single use - all sizes • soft flexible flange at for easy fixation • 15 mm connector at terminal end which can be rotated in 360 degree direction • non-irritant • radio-opaque line , tracheostomy tube (pvc), cuffed, sterile, single use - all sizes • soft flexible flange at for easy fixation • 15 mm connector at terminal end which can be rotated in 360 degree direction • non-irritant • radio-opaque line • balloon with non return valve , abdominal drain kit, sterile, having drainage catheter and collection bag (2000 ml) (size 24) • graduated bag • should have well fitting cap • soft drainage catheter 50 cm long, with radio opaque line • rounded open distal end with smooth atraumatic eyes in catheter • catheter with markings at 2 cm interval , abdominal drain kit, sterile, having drainage catheter and collection bag (2000 ml) (size 28) • graduated bag • should have well fitting cap • soft drainage catheter 50 cm long, with radio opaque line • rounded open distal end with smooth atraumatic eyes in catheter • catheter with markings at 2 cm interval , abdominal drain kit, sterile, having drainage catheter and collection bag (2000 ml) (size 32) • graduated bag • should have well fitting cap • soft drainage catheter 50 cm long, with radio opaque line • rounded open distal end with smooth atraumatic eyes in catheter • catheter with markings at 2 cm interval , corrugated drainage sheet, sterile, multichannel, with radio opaque line, single use - all sizes , polypropylene nonabsorbable synthetic surgical mesh 7.5 cmx 15 cm soft to feel fast edges,slightly stretchbonding. , polypropylene nonabsorbable synthetic surgical mesh 15 cmx 15 cm soft to feel fast edges,slightly stretchbonding. , sterilised umbilical cotton tape width 3 mm, length 75 cm should conform to schedule f(iii) of drug and cosmetic act 1940 , bone wax sterilised , temporary cardiac pacing wire (electrode) sterile ½ cir, tapercut, 26 mm; straight cutting 60 mm ,breakaway , skin graft knife blade (sterile) (disposable ) skin grafting knife blade (sterile) made of carbon steel or stainless steel material 158 mm long individually wrapped in wrapper corrosion inhibitor paper in single packet,.in packs of 10. the edge must be sharp enough to cut the skin in a single shave and should snugly fit in the handle should conform to is 3759. 2. skin grafting knife handle (watson modification of humby’s knife ) stainless steel, ce certified, in which the blade specified in (a) above should fit snugly. should conform to 7980-1976. , k wire, length 375 mm; 1mm length of wire should be mentioned with specification. should conform to is 8261 , k wire, length 375 mm;1.6mm • length of wire should be mentioned with specification. • should conform to is 8261 , k wire, length 375 mm; size 1.8mm • length of wire should be mentioned with specification. •should conform to is 8261 , face mask, disposable • should be manufactured from non woven poly prop fabric • should be 3 ply construction • should have high bacterial filtration efficiency • should be heat sealed to keep 3 layers together • standard size 17.5 x9 cm • color green/blue • there should be a string each at all four corners,length of string should be 40cm • nose clip should be there • no elastic band. , surgical cap, disposable (for surgeons) • should be manufactured from non woven fabric. • strip for tying the cap stitched on the back for proper grip on the forhead. • green colour • ultrasonically stitched • air permeable/breathable • should retain skin and hair particle. • strip for tying the cap , surgical cap, disposable ( for nurses) • should be manufactured from non woven fabric • blue / green colour • round upon wearing, with elastic • air permeable / breathable • should retain skin and hair particles , foldable intra ocular lense with injector (size + 11 d to +17.5 d) size:6mm optics. 12-13mm total diameter 1. made of foldable acrylic (hydrophobic) material 2. bi-convex single piece iol with aspheric optics 3. size:6mm optics. 12-13mm total diameter. 4. modified c loop haptic/plate haptics ( 5. iol should have uv blocking capability 6. iol should have 360°square edge.. 7. foldable and insertion by injector with disposable cartridge insertable by a sub 2.8 mm incision size or smaller incision 8. diopters- + 11 d to +17.5 d at 0.5 d step. 9. supplying unit should be iso accredited and iol should be ce/us fda certified. , foldable intra ocular lense with injector (size + 18 d to + 24 d) size:6mm optics. 12-13mm total diameter 1. made of foldable acrylic (hydrophobic) material 2. bi-convex single piece iol with aspheric optics 3. size:6mm optics. 12-13mm total diameter. 4. modified c loop haptic/plate haptics 5. iol should have uv blocking capability 6. iol should have 360°square edge.. 7. foldable and insertion by injector with disposable cartridge insertable by a sub 2.8 mm incision size or smaller incision 8. diopters- + 18 d to + 24 d at 0.5 d step. 9. supplying unit should be iso accredited and iol should be ce/us fda certified. , foldable intra ocular lense with injector (size + 24.5 d to + 28.5 d ) size:6mm optics. 12-13mm total diameter 1. made of foldable acrylic (hydrophobic) material 2. bi-convex single piece iol with aspheric optics 3. size:6mm optics. 12-13mm total diameter. 4. modified c loop haptic/plate haptics 5. iol should have uv blocking capability 6. iol should have 360°square edge.. 7. foldable and insertion by injector with disposable cartridge insertable by a sub 2.8 mm incision size or smaller incision 8. diopters- + 24.5 d to + 28.5 d at 0.5 d step. 9. supplying unit should be iso accredited and iol should be ce/us fda certified. , standard pmma intra ocular lenses (size + 11 d to +17.5 d) • 6mm optic size 12.5 - 13.0 mm total diameter, biconvex 1. pmma optics and haptics single piece with hole 2. 6mm optic size 12.5 to 13mm total diameter, biconvex 3. iol haptics – modified c shaped with 5° -10° anterior angulation. 4. should have 360° square edges. 5. iol should have uv blocking capability 6. diopters- + 11 d to +17.5 d at 0.5 d step. 7. supplying unit should be iso accredited and iol should be ce/us fda certified. , standard pmma intra ocular lenses (size + 18 d to + 24 d) • 6mm optic size 12.5 - 13.0 mm total diameter, biconvex 1. pmma optics and haptics single piece with hole 2. 6mm optic size 12.5 to 13mm total diameter, biconvex 3. iol haptics – modified c shaped with 5° -10° anterior angulation. 4. should have 360° square edges. 5. iol should have uv blocking capability 6. diopters- + 18 d to + 24 d at 0.5 d step. 7. supplying unit should be iso accredited and iol should be ce/us fda certified. , standard pmma intra ocular lenses (size + 24.5 d to + 28.5 d ) 6mm optic size 12.5 - 13.0 mm total diameter, biconvex 1. pmma optics and haptics single piece with hole 2. 6mm optic size 12.5 to 13mm total diameter, bioconvex 3. iol haptics – modified c shaped with 5° -10° anterior angulation. 4. should have 360° square edges. 5. iol should have uv blocking capability 6. diopters- + 24.5 d to + 28.5 d at 0.5 d step. 7. supplying unit should be iso accredited and iol should be ce/us fda certified. , disposable sterile surgical rubber gloves size 8 inches • made of natural rubber latex powdered,without tear,properly folded in a paper • should conform to is 13422 • isi marked/ce certified/fda approved • colour code marking to designate size , disposable sterile surgical rubber gloves size 8 inches • made of natural rubber latex powder free,without tear,properly folded in a paper • should conform to is 13422 • isi marked/ce certified/fda approved • colour code marking to designate size , rubber examination gloves made of natural rubber latex. non-sterile, ambidextous, aql 1.5 micro textured powdered with absorbable dusting powder usp. extra small. should conform to is 15354 , rubber examination gloves made of natural rubber latex. non-sterile, ambidextous, aql 1.5 micro textured powdered with absorbable dusting powder usp. small should conform to is 15354 , rubber examination gloves made of natural rubber latex. non-sterile, ambidextous, aql 1.5 micro textured powdered with absorbable dusting powder usp. medium should conform to is 15354 , rubber examination gloves made of natural rubber latex. non-sterile, ambidextous, aql 1.5 micro textured powdered with absorbable dusting powder usp. large should conform to is 15354 , pressure monitoring line / high pressure extension line • suitable for high pressure monitoring and for connection between syringe infusion pump and patient • male luer lock at one end and female luer lock at other end ; should fit all standard equipment. luer lock connectors should provide secure fitting. • pressure upto 800 psi • length 200 cm • sterile , urine collecting bag for new born /paediatric urine collection bag, capacity 100ml • should have suitability for both male and female patients • should be provided with adhesive for fixation and good grip with minimal risk of allergy and injury • capacity 100 ml • sterile , umbilical catheter (for new born) all sizes • radio opaque line • with female flexible mount • colour coded connector • open tip should be soft, rounded, atraumatic • length 40 cm , umbilical cord clamp • suitable for clamping umbilical cord of new born • security lock to prevent accidental opening after clamping • grooved clamping area , absorbable oxidized regenerated cellulose net size 2”x 3” with surgical sponge topical absorbable haemostatic bactericidal property , close wound drainage device under negative pressure (closed wound suction unit) • option to use one or two catheters simultaneously • bellow chamber with capacity 800 ml • bellow unit with connector • graduated bellow • connecting tube with clamp and “y”connector • curved needle / trocar with catheter • multiperforated catheter / radon drain with radio opaque line • catheter 16 fg , close wound drainage device under negative pressure (closed wound suction unit) • option to use one or two catheters simultaneously • bellow chamber with capacity 800 ml • bellow unit with connector • graduated bellow • connecting tube with clamp and “y”connector • curved needle / trocar with catheter • multiperforated catheter / radon drain with radio opaque line • catheter 18 fg , t – tube for common bile duct drainage • kehr’s t tube made from medical grade pvc, and siliconized • smooth, kink resistant • radio opaque line throughout the length • sterile • length 20 x 60 cm • size 10 to 18 fg , bone cement with antibiotics,fast and slow setting , general specificaition for s-99 (a) and s- 99(b) sanitary napkins (for menstrual hygiene) specifications:- • sanitary napkin consists of an outer covering provided with sufficient number of channels for leak protection and an absorbent filler material. • the sanitary napkins shall have a soft feel and when worn shall not chafe or give any uncomfortable feeling. should be odourless. • the material used in fabrication shall be non allergenic. • shall be free from acids and alkali. • each primary package shall contain 6 napkins in a polyethylene bag of good quality which should conform to size of product and sealed properly. • both upper and lower sheets shall be white in colour. • shall conform to is 5405. • type of material and size should be mentioned as per is 5405 • instruction for usage should be mentioned on every packet. , sanitary napkin, beltless 1. covering – covering of the absorbent filler shall be good quality knitted sleeve or non-woven fabric which has sufficient porosity to permit the assembled napkin to meet the absorbency requirements. the napkins shall have a non absorbent barrier on one side which shall have an identifying mark indicating the side of the barrier. 2. absorbent filler – the filler material shall consist of cellulose pulp/ wadding, and shall be free from lumps, oil spots, dirt or foreign material, etc. 3. back strip – a back strip for sticking the sanitary napkin onto the underwear should be there using good quality adhesive material. 4. size - the size of absorbent section / complete sanitary napkin shall be as follows: ( in mm) absorbent section total pad length 210 +_ 10 230 +_ 10 width 60 to 75 70 to 85 thickness 8 +_ 2 5. weight : not more than 10 gm . . instruction for usage should be mentioned on every packet , sanitary napkin, belttype 1. covering – covering of the absorbent filler shall be good quality knitted sleeve or non-woven fabric which has sufficient porosity to permit the assembled napkin to meet the absorbency requirements. the napkins shall have a non absorbent barrier on one side which shall have an identifying mark indicating the side of the barrier. 2. absorbent filler – the filler material shall consist of cellulose pulp/ wadding, and shall be free from lumps, oil spots, dirt or foreign material, etc 3. size - the size of absorbent section / complete sanitary napkin shall be as follows: ( in mm) absorbent section pad length 220 +_ 10 width 70 +_ 5 thickness 17 +_ 3 4. weight : 12 +_ 3 gm 5. pack – six napkins in a pack. 6. elastic belt with loops shall be provided in each pack. 7. absorbency: the napkin should be able to absorb not less than 30 ml of normal saline or coloured water or test fluid when poured on to the centre of the napkin at the rate of 15 ml per minute. .instruction for usage should be mentioned on every packet. , belt-less sanitary napkin with wings 1. covering (absorbing top sheet corrector)–good quality knitted sleeve or non woven fabric of rash free,non irritant and soft to touch material which has sufficient porosity to permit the assembled napkin to meet absorbency requirements.the napkins shall have a non absorbent barrier on one side with adhesive covered by a differently identifiable paper 2.overall length (mm) 230 ± 5 3.core length 220 mm± 10 4.fluff core/pad length 220 mm± 10 5. over all width with wings 160mm+_5 6.fluff core/pad length 70 mm± 5 7.thickness of a single pad 9-10mm 8. weight of a single pad : 8-10 gm 9. pack six napkins in a pack. 10 type.- belt-less sanitary napkin with wings 11. minimum absorbency: 50ml 12. ph value of absorbent material 6-8.5 b. disposable individual pouch or wrapper for each sanitary napkin(as per ministry of environment,forest and climate change dated 08.04.2016) pouch/wrapper specifications :- 1. pouch/wrapper should be of the size of sanitary napkin being supplied. 2. it should have adhesive to seal the sanitary napkins within. 3. pouch/wrapper should not be transparent. note : instructions for use of disposable pouch/wrapper mst be written in hindi on disposable pouch/wrapper. blrseky fd;s gq;s lsusvjh usifdu dks eksm dj disposable pouch/wrapper esa mkys ,oa disposable pouch/wrapper dks xksan yxh iv~vh ls cun dj lqjf{kr rjhds ls dwmsnku esa mkysaa , oxygen mask (adult) • mould facemask with adjustable elastic strap for proper position of mask on the mouth and nasal area • friendly soft medical pvc material with comfortable fitting. • aluminium nasal clip provides better fixation. • anatomical design provides lighter seal. • latex free elastic strap available. , oxygen mask (paediatric) • mould facemask with adjustable elastic strap for proper position of mask on the mouth and nasal area • friendly soft medical pvc material with comfortable fitting. • aluminium nasal clip provides better fixation. • anatomical design provides lighter seal. • latex free elastic strap available. • mask connector 4m , sterile catheter, single use, for urinary drainage(foley baloon catheter), 2 way, size 14 • made of silicone elastomer bonded with latex • should have hard plastic valve • smooth distal end with smooth eyes for a traumatic intubation • symmetrical foley balloon • balloon capacity 30+- 1 ml • should conform to is 11497 • color coding marking to identify size • length, wall thickness and ballon capacity should be mentioned as per is 11497 • specification for b,c,d,e,f,g should be mentioned as per is 11497 , nelaton - catheter size 14 fg distal end is close and proximal end has female colour code connector • soft, kink resistant medical grade pvc tube • length:40 cm • individually packed in poly and sterile , ecg electrode •reliable trace, •high conductivity,• easy to handle , surgical blade sterile, size 23 • single peel pack in metal foil • the tip of the blade shall be well defined, central and sharp. there shall be no waviness, jags, feathers, nicks, or other defects on the cutting edge. the surfaces of the blade shall be smooth and free from tool marks and any sign of corrosion. • should conform to is 3319 , sterile hypodermic syringe with needle attached, 22g, single use - 50 ml • clear transparent chamber • prominent graduation • inert material gasket at the piston to minimise friction during movement & prevent leakage and back flow • sharp needle ensuring minimum trauma during penetration • shall conform to is 12050 • packing: needle should be attached with the syringe and packed in unit ribbon pack • the words destroy after single use or equivalent should be written on unit container. , urethral catheter 90 (fg-14), made up of medical grade pvc , urethral catheter 91 (fg-10), made up of medical grade pvc , vaccum suction set, 2.5 meter length, •suction handle with suction tube •sterile,• pyrogenic free, •latex free,• single use , epidural minipack 18g, 90 mm, metal stylet for single use only, •sterile, •epidural catheter 20g, l 90 cm, •6 lateral holes closed end, •borst adapter •epidural catheter flat filter 0.2 micro meter •thread assist guide•lor (loss of resistance) plastic syringe 6 ml , vascular catheter with metal guide no. 16, double lumen size 30 cm (longline iv.) , vascular catheter with metal guide no. 18 double lumen size 30 cm (longline iv.) , vascular catheter with metal guide no. 20 double lumen size 30 cm (longline iv.) , vascular catheter with metal guide no. 22 double lumen size 30 cm (longline iv.) , vascular catheter with metal guide no. 16 double lumen size 45 cm (longline iv.) , vascular catheter with metal guide no. 18 double lumen size 45 cm (longline iv.) , vascular catheter with metal guide no. 20 double lumen size 45 cm (longline iv.) , vascular catheter with metal guide no. 22 double lumen size 45 cm (longline iv.) , 3 way stop cock , non pyrogenic & single use, should be leak proof, with smooth movements , 3 way stop cock with extension tube (vein -o-line) size 10 cm (non pyrogenic & single use) , 3 way stop cock with extension tube (vein -o-line) size 50 cm (non pyrogenic & single use) , 3 way stop cock with extension tube (vein -o-line) size 100 cm (non pyrogenic & single use) , 3 way stop cock with extension tube (vein -o-line) size 150 cm (non pyrogenic & single use) , abdominal drain kit, sterile, having drainage catheter and collection bag (2000 ml) (size 16) • graduated bag, • should have well fitting cap • soft drainage catheter 50 cm long, with radio opaque line • rounded open distal end with smooth atraumatic eyes in catheter • catheter with markings at 2 cm interval , abdominal drain kit, sterile, having drainage catheter and collection bag (2000 ml) (size 20) • graduated bag • should have well fitting cap • soft drainage catheter 50 cm long, with radio opaque line • rounded open distal end with smooth atraumatic eyes in catheter • catheter with markings at 2 cm interval , nasal pronge neonatal (flexible medical grade, 2 meter long, multichannel kink resistance tube , elastic adhesive bandage bp 1m x 10cm adhesive material should have good quality sticking property, non-allergic , sterile disposable (single use teflon/ptfe i.v cannula with integrated 3 way stop cock size 26g • should be packed in transparent single blister pack • should confirm to is 10555 standard • (neonatal iv cannula size 26) , niv mask (noninvasive ventilation mask) adult • should be light weight silicon based full face & nasal mask with face &forehead soft cushion pads for adults in large size. • should be with ergonomically designed clips/straps for easy disengagement of the head gear. • should be single use for ventilator without vent • non allergic, leak proof, contour should be maintained , niv mask (noninvasive ventilation mask) adult • should be light weight silicon based full face & nasal mask with face &forehead soft cushion pads for adults in medium size. • should be with ergonomically designed clips/straps for easy disengagement of the head gear. • should be single use for ventilator without vent • non allergic, leak proof, contour should be maintained , niv mask (noninvasive ventilation mask) adult • should be light weight silicon based full face & nasal mask with face &forehead soft cushion pads for adults in large size. • should be with ergonomically designed clips/straps for easy disengagement of the head gear. • should be single use for bipap with vent • non allergic, leak proof, contour should be maintained , niv mask (noninvasive ventilation mask) adult • should be light weight silicon based full face & nasal mask with face &forehead soft cushion pads for adults in medium size. • should be with ergonomically designed clips/straps for easy disengagement of the head gear. • should be single use for bipap with vent • non allergic, leak proof, contour should be maintained , niv mask (noninvasive ventilation mask) paediatric • should be light weight silicon based full face & nasal mask with face &forehead soft cushion pads in small size. • should be with ergonomically designed clips/straps for easy disengagement of the head gear • should be single use with bronchoscopy and co2 &o2 port with chin support • non allergic, leak proof, contour should be maintained , nebulization mask adult , nebulization mask paediatric , chemotherapy port &non-coring needles(adult) • valved catheter need only saline flush, catheter with intermediate size port with small septum and silicon filled suture holes, should be mri compatible with cathlock radio-opaque ring. 8fr with silicon material with peel apart percutaneous introducer system. • chemo port huber needle 20g and 22g. , chemotherapy port &non-coring needles(pediatric) • valved catheter need only saline flush, catheter with intermediate size power port with large septum and silicon filled suture holes, should be mri compatible with cathlock radio-opaque ring. 6fr with silicon material with peel apart percutaneous introducer system • .chemo port huber needle 20g and 22g. , core biopsy instrument with compatible co-axial needle (automatic disposal ) , disposable bone marrow biopsy needle , eyelid occlusion dressing , eye pressure shield , rebreathing beg 2 lit. , shoe cover , infant feeding tube size -6 , gelaspan 4% (gleatin pvc free bottle) , poly(lactide-co-glycolide) powered absorabale fixation device with counter display on firing handle , securement device with adhesive in the middle to secure catheters & tubings. waterproof, hypoallergenic & non-stretchable to retain the shape size: small (lines & tubes sized 1.5-4.5 mm) , securement device with adhesive in the middle to secure catheters & tubings. waterproof, hypoallergenic & non-stretchable to retain the shape size: medium (lines &tubes sized 3-8 mm) , ecg lead guided catheter for critically ill patents. triple lumen central venous catheter 5f (20/22/22) 8d made of certon, a special grade polyurethane, length 8cm valve needle having side port, novlon material dilator, scalpel,nitinol guidewire, safesite connector and ecg lead. , sequential electrical nerve stimulator with sense technology , securement device with adhesive in the middle to secure catheters & tubing. waterproof, hypoallergenic & non-stretchable to retain the shape size: large (lines & tubes sized 6-13 mm) , pencil point spinal needle size 25 g / 27 g shorter tip-to-back of eyelet distance (1.7mm). shorter tip-to-front of eyelet distance (1.05mm). eyelet is size 0.65mm , securement device with adhesive in the middle to secure catheters & tubing. waterproof, hypoallergenic & non-stretchable to retain the shape size: jugular , securement device with adhesive in the middle to secure catheters & tubings. waterproof, hypoallergenic & non-stretchable to retain the shape size: x-large (lines & tubes sized 6-15 mm) , titanium powered non absorabable fixation device with counter display on firing handle , regional anaesthesia single shot nerve blocks under hns12 machine. . 30’ bevel cut stiumplex ultra needle with 360 degree x markings visible & performed under ultrasound in sizes 35mm /50mm/100mm/150mm. , latex free disposable pencil point spinal needle 27g , 127.5 mm with grooved transparent hub with centering protective plastic sleeve, touhy needle with black eye - 18 g (1.3 x 88 mm). protrusion of spinal needle through the back eye of the epidural needle. with epidural catheter, filter, loss of resistance syringe and separate locking device - docking system. , disposable needle size - 18 , disposable needle size - 20 , disposable needle size - 22 , disposable needle size - 23 , disposable needle size - 24 , disposable needle size - 26 , eu ce marked,en13795,tuv approved with certified test for, resistance to microbial penetration test back table cover-150 x 190,4 towels-30 x 40,instrument placement- mayo stand 80 x 145,adhesive strip-9x50, swaddle cloth, fluid-absorbent nonwoven material 90 x 90,opaque layer, for the supine position, 230/200 x 312, with abdominal fenestration, 27 x 33 , eu ce marked, en13795,tuv approved with certified test for, resistance to microbial penetration test swaddle cloth with fluid absorbent nonwoven material size 90x100 cm , special smms , ce,iso,tuv,en13795 approveded, spunless closer types with cuff , surgical knife-cresent , surgical knife-keratome , surgical knife-mvr , eu ce marked,en13795,tuv approved with certified test for, resistance to microbial penetration test back table palcement-150 x 190,towels-30 x 20,instrument palcement- mayo stand 80 x 145,adhesive strip-9 x 25,adhesive cloak-75 x 90,adhesive cloak- bottom-175 x 170,adhesive cloak- top-140 x 240 , single use negative pressure wound therapy system (snpwt) 14days consists of a pioneering, silicone airlock™ technology battery- operated device create negative pressure-80mm/hg,low battery indicator,on/pause therapy button,pump is functioning properly indicator,air leak detected indicator,tubing connector,dressing full indicator,therapy start date label,sliding battery cover,moulded belt pump clip (provided with the 14 system) – transparent to enable visibility of pump labelling. (s, m, l) , drain tube & chest tube holder with silicon fixing plate & lock sets. high absorption around the drainage catheter, prevents the infection caused by the accumulation of seepage. , et tube holder with flexible channel having adjustable clamp & dual locking system for holding the et tube sizes between 7.0-10.0 i.d. , limb holder immobilizer with 150cm long strap with an integrated grip for attaching. , multifunctional mask- it should have provision of attaching nebulizing chamber, access for hydration, oral suction without interrupting oxygen therapy, special opening on sides to accommodate ng and og tubes. it should be designed to administer high oxygen. fda approved. it should have adapter, tubing & nebulizer. , iv bag & bottle spike with hydrophobic & antibacterial filter to prevent contamination of solutions. , dressing pad for single use negative pressure wound therapy 14days consists of a pioneering, silicone airlock™ technology (s,m,l) , porous collagen from fish source with mupirocin and metronidazole in particle form, size-10ml , endotracheal tube plain size - 2 , laryngeal mask airway all size , a single-use haemofilter designed to remove and/or control water, electrolytes and toxins in the blood by continuous extracorporeal circulation i.e renal replacement therapy, filled with hollow fibers made of polymethyl methacrylate (pmma), capable of adsorbing excess cytokines by filtration & adsorption , electrolysed non-toxic, non-irritant and non-corrosive, ready to use disinfectant solution with neutral ph containing sodium chloride (na cl)- )0.023%, sodium hypochlorite (naocl)- 0.005%, hypo chlorous acid (hocl)- 0.004%, electrolysed water- 99.97% in jerricane of 5 litre , cannuala fixer , intercostal drainage tube with trochar , super oxidized solution with neutral ph containing hypochlorous acid (0.003%) and sodium hypochlorite (0.004%) for wound treatment in spray bottle of 500ml , super oxidized solution with neutral ph containing hypochlorous acid (0.008%) and sodium hypochlorite (0.002%) for wound dressing in pump bottle of 120gm , bare fiber shall be oem compatible with the mesic 1470 nm class iv diode laser system and shall be designed for precise cutting, coagulation, and tissue ablation applications. the fiber shall be supplied with sma 905 connector compatibility and shall support core diameters from 320 µm to 600 µm with suitable numerical aperture for efficient laser energy transmission. , intercostal drainage bag , baby i.d. bands (tag) , pure poly siloxane based silicone scar management product in gel form (100% poly siloxane)-10gms , radial fiber shall be specifically designed for circumferential laser energy emission compatible with mesic 1470 nm diode laser systems. the fiber shall provide uniform 360-degree radial energy distribution for minimally invasive therapeutic procedures and shall be supplied with oem-compatible sma 905 connector configuration. , medical body protector premium , class 1 ec medical device with accuracy and waterproof adhesive thermochromic temperature indicator with three colour code , iv cap disinfectant cap having passive disinfection to protect hubs /ports by acting as a physical barrier to contamination between accesses. , secura tracheostomy tube holder neckband with absorbent foam . , pure link double needle free connectors fixed to bifurcated macrobore extension set with luer lock & slide clamps. , nano cap for ports prevention. , conical fiber shall be oem compatible with the mesic 1470 nm class iv diode laser system and shall be designed to provide focused conical laser beam delivery for enhanced cutting and coagulation performance. the fiber shall support high-efficiency laser transmission with optimized distal tip geometry suitable for surgical applications. , extremity set ( knee replacement kit ) mention below specs,eu ce marked,en13795,tuv approved with certified test for, resistance to microbial penetration test (dry & wet),resistance to liquid penetration test, cleanliness test. (microbial & particulate matter),bursting strength ( dry & wet),tensile strength test ( dry & wet),linting test. back table cover-150 x 190,towels-30 x 20,adhesive strip-9 x 25,instrument table cover- mayo stand-80 x 145,ot drape sheet-150x150stockinette-33x55,adhesive film strips-10x50,extremity drape-200x300 , non alcoholic barrier spray 360 fumes , horizontal drain/tube attachment device skin barrier with elastaflex backing,size.5-40 fg , pur-xro 28g/1fr picc catheter 20cm length with stylet, spliting introducer needle,securing wings, measuring tape and every cm marking , flow rate 0.7ml/min with 8 cm extension tubing and clamp , radiopaqe wit expert technology, contaning agion™ antimicrobial agent catheter 40cm with 3.5, 4,5,8 fr compatible for both arterial and venus route with female luerlock supplied with stopcock and colour coded clip , pur-xro 22g catheter with stight guidwire and introducer with integral extension and clamp . length 4,6,8,10,20cm , pe baby wrap double layer green house has bed with adjustable hud, front velco and spine support for pre term baby to avoide hypothermia size small,medium,large , lisa catheter 6fr 20cm with 2cm black blunt angled soft distal tip. bendable material, centimetric marking, low dead space 0.2ml. , v-tad,vertical tube attachmemt device skin barrier with elastaflex backing.size.5 – 40 fg , f – tad, feeding tube attachment device, unique clamping mechanism & attached skin barrier for ng tube, size.5-18 fg. , locked pur antireflex valve with silicon duff 10 cm 2 lumen and 3 luman extension tube with colour coated clip , pur 7.5fr triple tumen(14/18/18) catheter 12.5cm with bls valve and natinol guidewire , double needle free connectore fixed to bifurcated minibore extension set with luer lock & slide clamps. , polyethylene arterial catheter 20 g length 8 cm seldinger technique with antikinking collar comes with puncture needle 20 g , endoscopic linear cutter disposable endoscopic stapler with universal handle and 160 mm shaft, allowing up to 12 firings per handle. compatible with 45 mm and 60 mm cartridges, each featuring 6 rows of b-shaped staples for superior staple line security. proximally controlled 45° articulation, 360° rotation knob, and wide jaw opening ensure precise tissue placement with ridges and improved perfusion. equipped with new knife blade per firing, stepped compression to reduce tissue trauma, safety interlock to prevent misfiring, consistent stapling technology, slimmer and stronger anvil, blade position indicator, and loop handle for easy gripping and firing. packing: 1 piece per box. with 6 assorted reloads of open staple height: 2.0–3.0 mm, closed staple height: 0.75–1.25 mm / open staple height: 3.0–4.0 mm, closed staple height: 1.25–1.75 mm / open staple height: 4.0–5.0 mm, closed staple height: 1.75–2.25 mm. minimum last 3 years msc is mandatory. , s/m/l size garments for vest airway machine , convex synthetic skin barrier withfloating flange centre point locking system. size.70 mm. can be cut up to 13-51 mm , soft easy to squeeze tube for filling the uneven peristomal area, low in alcohol to minimize stinging ,improve the fit of skin barrier (60 gm) , stoma powder , 28 gm. is use to absorb extra moisture from broken peristomal area which allows for better barrier adhesion& help to reduce itchiness and excoriation. after applying skin barrier. , skin gel wipes .helps prevent irritation associated with removal of adhesives. acts as a protective interface between skin and bodily wastes and fluids when used with adhesive products. in sachet form alchohal free , colostomy skin conditioning cream,soothes irritated dry skin,improving tolerance .to repeated tape and barrier use. contains aloe vit.a,d & e. 118 ml. (bottle) , ostomy wdc for wound upto 10 x 20 cm with odour barrier film, , excess cap synthetic skin barrier , resorbable collagen based sealing hemostat- material of construction: bovine collagen patch, nhs-peg (n-hydroxysuccinimide polyethylene glycol) and brilliant blue fcf dimension: 45mm * 90 mm , resorbable collagen based sealing hemostat- material of construction: bovine collagen patch, nhs-peg (n-hydroxysuccinimide polyethylene glycol) and brilliant blue fcf dimension: 45mm * 45 mm , incare inview (cv sheath) silicone ,self adhesive.size. 25/29/32/36 mm. , disposable monopolar pencil with tip cleaner , hemostatic matrix with thrombin 5 ml . pre-filled syringe of bovine-derived spherical gelatin granule matrix along with a vial of human-derived thrombin component (500iu/ml) & 0.9% sodium chloride solution for needle-free reconstitution. 5ml syringe applicator tips are included to facilitate the delivery of product. , non- lead radiationprotection gloves – bis certified , drainable pouch with skin barrier with integrated lock ‘n rollmicroseal closure & has af 300 filter to reduce the odour and balooning. cutting area upto 55 mm , drainable pouch with skin barrier with integrated lock ‘n rollmicroseal closure & has af 300 filter to reduce the odour and balooning. cutting area upto 65 mm , drainable pouch with integral convexity skin barrier with integrated microseal closure has af 300 filter to reduce the balooning. cutting area up to 51 mm , triple chambered nutrition(3 in one) for periperal iv emlusions 1000ml-1200ml with 80% olive /20% soya lipid,amino acids,glucose & electrolytes. tpn 1ltr triple chamber bag should contain protein 20-45 gm/l lipid 20-40gm/l glucose 80-160 gm/l , triple chambered nutrition(3 in one) for periperal iv emlusions 1800ml-2100ml with 80% olive /20% soya lipid,amino acids,glucose & electrolytes. tpn 1ltr triple chamber bag should contain protein 20-45 gm/l lipid 20-40gm/l glucose 80-160 gm/l , synthetic absorbable knotless barbed surgical suture made of pga-pcl (poly glycolic acid–polycaprolactone), violet coloured, unidirectional barbed, size 2-0, 15 cm length, with 1/2 circle round body needle, 27 mm, sterile. the suture and its needle should be indigenous in nature and backed up with valid supporting certification/documentary evidence from the manufacturer. , curos caps for needleless connectors alcohol-containing caps that twist onto needleless connectors in iv ports for disinfection and protection. each cap contains 70% isopropyl alcohol (ipa) which bathes the surface of the port and disinfects it in 1 minute and protects ports for up to 7 days if not removed. it should be 10 caps per strip. , polyhexamethylene biguanide hydrochloride, alkyl dimethyl benzylammonium chloride, didecyl dimethyl ammonium chloride , multicomponent compression system with pressure spot indicator circle, composed of a short stretch & long stretch bandage made of viscose, polyester, polyamide and elastane. size: 18- 25 cm (length) , 10 cm (width), european ce approved , g dress 10.5*25cm , g dress 8.5*6.5cm , healing matrix with technology lipidocolloid with agso4- having carboxymethyl cellulose and fat particles, 4-digit european ce certified, size-15x20cm , healing matrix with technology lipidocolloid with agso4- having carboxymethyl cellulose and fat particles, 4-digit european ce certified, size-10x12cm , advaced fluid aministration system with air stop and prime stop with itegrated back check valve bacterial retention air vent, transparent spike designed in accordance with iso 8536-4, transparent drip chamber (double),15 micron fluid filter in the chamber,medical grade, dehp free transparent kink free tubing. usfda/ce approved , the sterile native collagen sheet (ecm-based) shall be biocompatible as per iso 10993, non‑toxic, non‑allergenic, and non‑immunogenic. it shall comply with risk‑management requirements in en iso 14971:2012 and en iso 22442:2007,and meet the standards of iso 22442 (parts 1–3) to ensure proper sourcing, collection, and handling, as well as validation of the elimination or inactivation of viruses. the material shall be free from viral and other transmissible microorganisms. the product shall use non‑denatured, wet, bovine collagen with consistent thickness and elasticity , fully automatic non ported closed iv catheter with passive safety shield located inside the hub before activation deploys automatically, cannot be bypassed and requires no user activation, catheter material fep/certon, four embedded radio-opaque contrast lines, universal back cut bevel, multi-access blood control septum to prevent blood exposure, hydrophobic membrane with transparent flashback chamber and double flashback mechanism, integrated stabilization platform, power injectable – pressure rated for contrast media application at 300 psi (18g ) usfda/ce approved , fully automatic non ported closed iv catheter with passive safety shield located inside the hub before activation deploys automatically, cannot be bypassed and requires no user activation, catheter material fep/certon, four embedded radio-opaque contrast lines, universal back cut bevel, multi-access blood control septum to prevent blood exposure, hydrophobic membrane with transparent flashback chamber and double flashback mechanism, integrated stabilization platform, power injectable – pressure rated for contrast media application at 300 psi 20g usfda/ce approved , fully automatic non ported closed iv catheter with passive safety shield located inside the hub before activation deploys automatically, cannot be bypassed and requires no user activation, catheter material fep/certon, four embedded radio-opaque contrast lines, universal back cut bevel, multi-access blood control septum to prevent blood exposure, hydrophobic membrane with transparent flashback chamber and double flashback mechanism, integrated stabilization platform, power injectable – pressure rated for contrast media application at 300 psi (22g) usfda/ce approved , synthetic absorbable knotless barbed surgical suture made of polydioxanone (pdo), violet coloured, unidirectional barbed, size 1-0, 15 cm length, with 1/2 circle round body needle, 37 mm, sterile. the suture and its needle should be indigenous in nature and backed up with valid supporting certification/documentary evidence from the manufacturer. , synthetic absorbable knotless barbed surgical suture made of polydioxanone (pdo), violet coloured, unidirectional barbed, size 1-0, 30 cm length, with 1/2 circle round body needle, 37 mm, sterile. the suture and its needle should be indigenous in nature and backed up with valid supporting certification/documentary evidence from the manufacturer. , the sterile native collagen sheet (ecm-based) shall be biocompatible as per iso 10993, non‑toxic, non‑allergenic, and non‑immunogenic. it shall comply with risk‑management requirements in en iso 14971:2012 and en iso 22442:2007,and meet the standards of iso 22442 (parts 1–3) to ensure proper sourcing, collection, and handling, as well as validation of the elimination or inactivation of viruses. the material shall be free from viral and other transmissible microorganisms. the product shall use non‑denatured, dry, bovine collagen with consistent thickness and elasticity. size-15x30cm , synthetic absorbable knotless barbed surgical suture made of polydioxanone (pdo), violet coloured, unidirectional barbed, size 2-0, 25 cm length, with 1/2 circle round body needle, 27 mm, sterile. the suture and its needle should be indigenous in nature and backed up with valid supporting certification/documentary evidence from the manufacturer. , eu ce marked,en13795,tuv approved with certified test for, resistance to microbial penetration test size 75x 120 cm,non-woven under skirt and layer with high-absorbency, fluid-impermeable nonwoven material with polyethylene backing, featuring ultrasonic-sealed edges for leak prevention surgical drape standards for single-use . , eu ce marked,en13795,tuv approved with certified test for, resistance to microbial penetration test back table cover-150 x 190,towels-30 x 40,instrument table cover- mayo stand 80 x 145,adhesive strip-50x50,swathe with fenestration,with integrated fluid collection pouch, with lateral gutters incl. sieve and drainage port,with integrated tube fixations , double lumen central venous catheter 7f (16g/16 g), made of certon, a special grade polyurethane, length 15/20 cm, 18 g valve needle having side port, novlon material dilator, scalpel, nitinol guidewire, safesite connector and ecg lead usfda/ce approved , amorphous hydrogel in applipak composing of 2.3% carboxymethylcellulose,20.0% propylene glycol & purified water, promotes rapid but gentle debridement of necrotic tissue. size 25gm , adhesive porous wound dressing heel shaped change indicator technology with pad 20 - 25 x 20 - 25 cm , disposable handpiece to be used with hydrosurgery based debidement unit for quick and precision based debridement in a non ot environment size of 45⁰ and 14mm and 15⁰ 14mm , transparent, visual observation ofthe surgical site, highly extensible 0.03mm thick permeable to gas and moisture vapour, prevents fluid build-up and dressing lift high quality initial pressure sensitive tack maintain dressing position on patients skin,reduce the occurrence of skin sensitization. provides sustained adhesion during long, manipulative procedures. sizes : 45x55cm , triple lumen central venous catheter 7f (16g/18g/18 g), made of certon, a special grade polyurethane, length 15/20 cm, 18 g valve needle having side port, novlon material dilator, scalpel,nitinol guidewire, safesite connector and ecg lead usfda/ce approved , disposable curved circular stapler 29/ 31 mm with three circular staggeted staple lines (3 rows) and optimized staple formation techinque, tissue compression indicator, open staple leg length of 4.5 mm which can accommodates compressed tissue thickness from 1.0- 2.5 mm , disposable linear cutter stapler with dual side firing feature, anti slip body, rear hinge locking for intermediate position, push button for quick opening and interchangeable blue & green reloads , dispsable blue repoad/ green reload for use with 60 mm linear cutter stapler with fresh knife & safety lock, available in pet blister ray, reload should have an open leg length of 3.8 mm (blue reload), 4.8 mm (green relaod) and closed staple height of 1.5 mm (blue reload), 2.0 mm (green reload, staple lenght of 6 mm & cut lenght of 60 mm , disposable blue reload/ green reload for use with 80 mm linear cutter stapler with fresh knife & safety lock, available in pet blister tray, reload should have an open leg length of 3.8 mm (blue reload), 4.8 mm (green reload) and closed staple height of 1.5 mm (blue reload), 2.0 mm (green reload) statple length of 84 mm & cut length of 80 mm , disposable hemorrhoidal circular stapler 34 mm/ 36 mm with three circular staggered staple lines (3 rows) and optimized staple formation technique, tissue compression indicator, housing capacity 14cc, total 48 titanium staple pins with open staple leg length of 3.5 mm which can accommodate compressed tissue thichness from 0.75 to 1.6 mm , non oxidized regenerated cellulose and bioabsorbable ce class iib or class iii approved hemostat.forms 3d gel and effective in mild, moderate and severe bleeding management during surgical procedures.(woundclot surgical) / ce & usfda , non oxidized regenerated cellulose and bioabsorbable ce class iib or class iii approved hemostat.forms 3d gel and effective in mild, moderate and severe bleeding management during trauma .(woundclot trauma)/ ce & usfda , non oxidized regenerated cellulose and bioabsorbable ce class iib or class iii approved hemostat.forms 3d gel and effective in mild, moderate and severe bleeding management during trauma .(woundclot trauma)/ ce & usfda , waterproof cast & bandage protector • pvc (polyvinyl chloride) • ppe (polypropylene elastomer) • silicone (for the barrier) • latex-free: the product must be free of latex to prevent allergic reactions. • elasticity: must provide sufficient stretch and durability.waterproofing: 100% waterproof, tested for complete protection against water penetration. • durability: must last through daily use for a minimum of 4-6 weeks without significant wear. • temperature resistance: able to withstand warm water up to 40°c.iso certification: iso 13485 or equivalent. • safety standards: compliance with fda, ce marking, or bis standards. • biocompatibility testing: ensures the product is safe for prolonged contact with skin , waterproof cast & bandage protector • pvc (polyvinyl chloride) • ppe (polypropylene elastomer) • silicone (for the barrier) • latex-free: the product must be free of latex to prevent allergic reactions. • elasticity: must provide sufficient stretch and durability.waterproofing: 100% waterproof, tested for complete protection against water penetration. • durability: must last through daily use for a minimum of 4-6 weeks without significant wear. • temperature resistance: able to withstand warm water up to 40°c.iso certification: iso 13485 or equivalent. • safety standards: compliance with fda, ce marking, or bis standards. • biocompatibility testing: ensures the product is safe for prolonged contact with skin , waterproof cast & bandage protector • pvc (polyvinyl chloride) • ppe (polypropylene elastomer) • silicone (for the barrier) • latex-free: the product must be free of latex to prevent allergic reactions. • elasticity: must provide sufficient stretch and durability.waterproofing: 100% waterproof, tested for complete protection against water penetration. • durability: must last through daily use for a minimum of 4-6 weeks without significant wear. • temperature resistance: able to withstand warm water up to 40°c.iso certification: iso 13485 or equivalent. • safety standards: compliance with fda, ce marking, or bis standards. • biocompatibility testing: ensures the product is safe for prolonged contact with skin , waterproof cast & bandage protector • pvc (polyvinyl chloride) • ppe (polypropylene elastomer) • silicone (for the barrier) • latex-free: the product must be free of latex to prevent allergic reactions. • elasticity: must provide sufficient stretch and durability.waterproofing: 100% waterproof, tested for complete protection against water penetration. • durability: must last through daily use for a minimum of 4-6 weeks without significant wear. • temperature resistance: able to withstand warm water up to 40°c.iso certification: iso 13485 or equivalent. • safety standards: compliance with fda, ce marking, or bis standards. • biocompatibility testing: ensures the product is safe for prolonged contact with skin , waterproof cast & bandage protector • pvc (polyvinyl chloride) • ppe (polypropylene elastomer) • silicone (for the barrier) • latex-free: the product must be free of latex to prevent allergic reactions. • elasticity: must provide sufficient stretch and durability.waterproofing: 100% waterproof, tested for complete protection against water penetration. • durability: must last through daily use for a minimum of 4-6 weeks without significant wear. • temperature resistance: able to withstand warm water up to 40°c.iso certification: iso 13485 or equivalent. • safety standards: compliance with fda, ce marking, or bis standards. • biocompatibility testing: ensures the product is safe for prolonged contact with skin , waterproof cast & bandage protector • pvc (polyvinyl chloride) • ppe (polypropylene elastomer) • silicone (for the barrier) • latex-free: the product must be free of latex to prevent allergic reactions. • elasticity: must provide sufficient stretch and durability.waterproofing: 100% waterproof, tested for complete protection against water penetration. • durability: must last through daily use for a minimum of 4-6 weeks without significant wear. • temperature resistance: able to withstand warm water up to 40°c.iso certification: iso 13485 or equivalent. • safety standards: compliance with fda, ce marking, or bis standards. • biocompatibility testing: ensures the product is safe for prolonged contact with skin the silicone barrier, anti-slip grip, and the pvc hanging hole , waterproof cast & bandage protector • pvc (polyvinyl chloride) • ppe (polypropylene elastomer) • silicone (for the barrier) • latex-free: the product must be free of latex to prevent allergic reactions. • elasticity: must provide sufficient stretch and durability.waterproofing: 100% waterproof, tested for complete protection against water penetration. • durability: must last through daily use for a minimum of 4-6 weeks without significant wear. • temperature resistance: able to withstand warm water up to 40°c.iso certification: iso 13485 or equivalent. • safety standards: compliance with fda, ce marking, or bis standards. • biocompatibility testing: ensures the product is safe for prolonged contact with skin the silicone barrier, anti-slip grip, and the pvc hanging hole , waterproof cast & bandage protector • pvc (polyvinyl chloride) • ppe (polypropylene elastomer) • silicone (for the barrier) • latex-free: the product must be free of latex to prevent allergic reactions. • elasticity: must provide sufficient stretch and durability.waterproofing: 100% waterproof, tested for complete protection against water penetration. • durability: must last through daily use for a minimum of 4-6 weeks without significant wear. • temperature resistance: able to withstand warm water up to 40°c.iso certification: iso 13485 or equivalent. • safety standards: compliance with fda, ce marking, or bis standards. • biocompatibility testing: ensures the product is safe for prolonged contact with skin the silicone barrier, anti-slip grip, and the pvc hanging hole , waterproof cast & bandage protector • pvc (polyvinyl chloride) • ppe (polypropylene elastomer) • silicone (for the barrier) • latex-free: the product must be free of latex to prevent allergic reactions. • elasticity: must provide sufficient stretch and durability.waterproofing: 100% waterproof, tested for complete protection against water penetration. • durability: must last through daily use for a minimum of 4-6 weeks without significant wear. • temperature resistance: able to withstand warm water up to 40°c.iso certification: iso 13485 or equivalent. • safety standards: compliance with fda, ce marking, or bis standards. • biocompatibility testing: ensures the product is safe for prolonged contact with skin the silicone barrier, anti-slip grip, and the pvc hanging hole , waterproof cast & bandage protector • pvc (polyvinyl chloride) • ppe (polypropylene elastomer) • silicone (for the barrier) • latex-free: the product must be free of latex to prevent allergic reactions. • elasticity: must provide sufficient stretch and durability.waterproofing: 100% waterproof, tested for complete protection against water penetration. • durability: must last through daily use for a minimum of 4-6 weeks without significant wear. • temperature resistance: able to withstand warm water up to 40°c.iso certification: iso 13485 or equivalent. • safety standards: compliance with fda, ce marking, or bis standards. • biocompatibility testing: ensures the product is safe for prolonged contact with skin the silicone barrier, anti-slip grip, and the pvc hanging hole , waterproof cast & bandage protector • pvc (polyvinyl chloride) • ppe (polypropylene elastomer) • silicone (for the barrier) • latex-free: the product must be free of latex to prevent allergic reactions. • elasticity: must provide sufficient stretch and durability.waterproofing: 100% waterproof, tested for complete protection against water penetration. • durability: must last through daily use for a minimum of 4-6 weeks without significant wear. • temperature resistance: able to withstand warm water up to 40°c.iso certification: iso 13485 or equivalent. • safety standards: compliance with fda, ce marking, or bis standards. • biocompatibility testing: ensures the product is safe for prolonged contact with skin the silicone barrier, anti-slip grip, and the pvc hanging hole , waterproof cast & bandage protector • pvc (polyvinyl chloride) • ppe (polypropylene elastomer) • silicone (for the barrier) • latex-free: the product must be free of latex to prevent allergic reactions. • elasticity: must provide sufficient stretch and durability.waterproofing: 100% waterproof, tested for complete protection against water penetration. • durability: must last through daily use for a minimum of 4-6 weeks without significant wear. • temperature resistance: able to withstand warm water up to 40°c.iso certification: iso 13485 or equivalent. • safety standards: compliance with fda, ce marking, or bis standards. • biocompatibility testing: ensures the product is safe for prolonged contact with skin the silicone barrier, anti-slip grip, and the pvc hanging hole , sterile disposable single-use skin stapler with ss 316l staples having dimensions approximately 5.7 mm width, 3.9 mm closed height and 0.6 mm wire diameter. handle should be made of medical grade abs with polycarbonate cartridge and ss 304 guideway/pusher. device should ensure consistent staple formation with precision press-fit technology for reliable firing performance. product should be supported with indigenous manufacturing certificate from the manufacturer
BOQ
| Sl. No. | Item Description |
| 1 | SRG Hospital |
| 2 | Nonabsorbable Polypropylene light weight macroporous mesh |
| 3 | Three dimensional monofilament polyester composite mesh with collagen with glycerol Anti Adhesive barrier visceral side and stay suture in parietal side along with medial medial |
| 4 | Three dimensional monofilament polyester composite mesh with collagen with glycerol Anti Adhesive barrier visceral side and stay suture in parietal side along with medial medial |
| 5 | Three dimensional monofilament polyester composite mesh with with collagen with glycerol Anti Adhesive barrier visceral side and stay suture in parietal side along with medial medial |
| 6 | Absorbable 5 mm Hernia mesh fixation device 30 screw shaped with proximal wings of PGLA tacks of 4.1 mm length along with flexible shaft up to 3 cm. |
| 7 | Absorbable 5 mm Hernia mesh fixation device 15 screw shaped with proximal wings of PGLA tacks of 4.1 mm length along with flexible shaft up to 3 cm. |
| 8 | Non absorbable 5 mm hernia mesh fixation device with 30 helical shaped Titanium tacks 3.96mm width and 0.61 mm diameter |
| 9 | 5mm Nonabsorbable helical fastener made up of medical grade stainless steel covered with atraumatic polymer (PEEK) cap to avoid metal exposure with 15 fasteners |
| 10 | 5mm Nonabsorbable helical fastener made up of medical grade stainless steel covered with atraumatic polymer (PEEK) cap to avoid metal exposure with 30 fasteners |
| 11 | Light weight monofilament polypropylene mesh, Design to confirm inguinal anatomy, 3D shape |
| 12 | Light weight monofilament polypropylene mesh, Design to confirm inguinal anatomy, 3D shape |
| 13 | Light weight monofilament polypropylene mesh, Design to confirm inguinal anatomy, 3D shape |
| 14 | Light weight monofilament polypropylene mesh, Design to confirm inguinal anatomy, 3D shape |
| 15 | Battery Operated 60mm Articulating Endo Cutter with a disposable battery pack, for enhanced distal tip stability while firing, having closed channel in the cartrdige jaw for better stability during firing, 360 degree rotation shaft and one handed natural articulation up to 45 degrees, Precision Machined Anvil to deliver initial, system wide compression, Wide Proximal to Distal Jaw Aperture (proximal 8mm , Distal 22mm) , 3 Point Gap Control for alignment and calibration throughout the 60 mm staple line, Knife direction/reverse control to discontinue the firing and return the knife, interchangeable 6 row cartridge options of white, blue ,gold, green and black, all fits down to 12mm trocar sleeve, 440 mm shaft length - 60 mm stapler |
| 16 | Linear cutter 55mm with six rows, 3D Staple formation, option of closed staple height of 1.5mm/1.8mm/2mm in one cartridge only |
| 17 | Linear cutter 75mm with six rows, 3D Staple formation, option of closed staple height of 1.5mm/1.8mm/2mm in one cartridge only |
| 18 | Universal linear cutter cartridge 75mm open linear cutter compatible with selectable staple height linear cutter 75mm.option of closed staple height of 1.5mm/1.8mm/2mm in one cartridge only. 6 Rows 3-D staple technology. |
| 19 | Universal linear cutter cartridge 55mm for open linear cutter compatible with selectable staple height linear cutter 55mm.option of closed staple height of 1.5mm/1.8mm/2mm in one cartridge only. 6 Rows 3-D staple technology. |
| 20 | Curved cutter stapler 40 mm linear cutter simultaneous cutting and stapling |
| 21 | Curved green cartridge having close staple height of 2.0 mm, tactile feedback on completion of firing sequence, new anvil, knife with every catridge |
| 22 | Powered Circular stapler 29 mm with 3D staple and not slip grip |
| 23 | Powered Circular stapler 31mm with 3D staple and not slip grip |
| 24 | Circular stapler 33mm with controlled tissue compression with adjustable staple height (1.0-2.5 mm) for controlled tissue compression, longer staple leg 5.5mm & Non slip grip surface |
| 25 | Laparoscopic cartridge for stapler 60 mm Blue, 1.5 mm closed staple height with gripping surface technology and six rows compatible with all range of Endoscopic linear cutter 60mm |
| 26 | Laparoscopic cartridge for stapler 60 mm Green, 2.0 mm closed staple height with gripping surface technology and six rows compatible with all range of Endoscopic linear cutter 60mm |
| 27 | PPH stapler 33mm - Hemorrhoidal stapler kit consists of 33mm Hemorrhoidal Circular stapler (with fixed anvil, adjustable closed staple height from 0.75 mm – 1.5 mm, staple open leg length of 5.5 mm), Suture Threader, Circular Anal Dilator, Purse-String Suture Anoscope, Suture for Purse String. |
| 28 | Optically guided bladeless trocar 12mm with bilateral tissue separators, optical tip to eliminate blind entry, clear ribbed cannula to enhance abdominal wall retention, recessed stopcock valve, funnel shaped housing, duckbill secondary seal, integrated universal seal that eliminates the use of reducer, 150mm length. |
| 29 | Optically guided bladeless trocar 12 mm with bilateral tissue separators, optical tip to eliminate blind entry, clear ribbed cannula, recessed stopcock valve, funnel shaped housing, duckbill secondary seal, integrated universal seal that eliminates the use of reducer length 100mm. |
| 30 | Facial closure device contain - Optical bladeless trocar with facial closure device comaptible with clear cannula have two side opening meant for uniform port closure |
| 31 | Varied Staple Height reloads/cartridges for 60 mm GIA instruments with Tri-Staple technology, with the cutting knife blade incorporated in the reloads itself, with purple varied staple height of 3, 3.5 and 4mm leg length |
| 32 | Varied Staple Height reloads/cartridges for 80 mm GIA instruments with Tri-Staple technology, with the cutting knife blade incorporated in the reloads itself, with purple varied staple height of 3, 3.5 and 4mm leg length |
| 33 | Linear cutter with Varied staple height, Tri-Staple technology-enabled reloads integration with left and right firing knob(both side firing) ,linear cutter stapler with integrated gap control technology in 60 mm Tristaple GIA stapler, Compatible with Tri-Staple GIA 60 mm open Linear cutter reloads/cartridges purpule and black |
| 34 | EEA circular stapler Purple colour medium thick , triple row with tristaple technology (three row of staple inner to outer row 3.0,3.5 and 4.0 mm with sloped cartridges face in one stapler) diameter 31mm |
| 35 | Linear cutter with Varied staple height, Tri-Staple technology-enabled reloads integration with left and right firing knob(both side firing) ,linear cutter stapler with integrated gap control technology in 80 mm Tristaple GIA stapler, compatible with Tri-Staple GIA 80 mm open Linear cutter reloads/cartridges purpule and black |
| 36 | Wound Protector with double Ring in Small 2.5-6 cm USFDA Approved |
| 37 | Wound Protector with double Ring in Medium 5-9 cm |
| 38 | Wound Protector with double Ring in Large in size 9-14 cm USFDA Approved |
| 39 | Endo Catch Specimen Removal Kit:with continuous ring ,polyurethane pouch with 34.5 cm shaft length , 10mm with leakproof and impervious material to cancer cells of 0.5 microns/ pretied purse string on pouch USFDA Approved |
| 40 | Disposable laparoscopic Clip Applier Preloaded with 16 clips, 5mm diameter with Clip logic technology and digital display Titanium Clips- U shaped |
| 41 | Laparoscopic liner cutter without integrated fresh knife with 360*rotation & 0-45* articulation in both direction : for use with cartridges in sizes of 30mmCapable of loading all length cartridges on same gun only |
| 42 | Laparoscopic liner cutter without integrated fresh knife with 360*rotation & 0-45* articulation in both direction : for use with cartridges in sizes of 45mm Capable of loading all length cartridges on same gun only |
| 43 | Laparoscopic liner cutter without integrated fresh knife with 360*rotation & 0-45* articulation in both direction : for use with cartridges in sizes of 60mm, Capable of loading all length cartridges on same gun only |
| 44 | Hand activated curved taper tip coagulating shears compatible with ultrasonic cutting and coagulation device,9cm length,16mm curved active blade with Adaptive Tissue Technology capable of sealing blood vessels up to and including 5mm in diameter, with ergonomic symmetrical finger ring grip- focus 9 |
| 45 | Hand activated curved taper tip coagulating shears compatible with ultrasonic cutting and coagulation device,17cm length,16mm curved active blade with Adaptive Tissue Technology capable of sealing blood vessels upto and including 5mm in diameter, with ergonomic symmetrical finger ring grip - Focus 17 |
| 46 | Advance Bipolar Hand Activated probe with 5mm shaft diameter and 35 cm shaft length with 5 mm wide straight jaw design with seal length of 20mm and cut length of 16mm,sealing vessel upto and including 7mm through radio frequency energy and having a temperature controlled mechanism within the jaw and having articulation of 110 degree(55 degrees on both sides) and capable of 360 degrees rotation |
| 47 | Advance Bipolar Hand Activated probe with 5mm shaft diameter and 45 cm shaft length with 5 mm wide straight jaw design with seal length of 20mm and cut length of 16mm,sealing vessel upto and including 7mm through radio frequency energy and having a temperature controlled mechanism within the jaw and having articulation of 110 degree(55 degrees on both sides) and capable of 360 degrees rotation |
| 48 | Advance Bipolar Hand Activated probe for open surgery with 13mm shaft diameter and 20 cm shaft length, 6 mm wide straight jaw design with jaw length of 38 mm ,sealing vessel upto and including 7mm through radio frequency energy , having separate seal and cut buttons, capable of 360 degrees rotation |
| 49 | Laparoscopic shears 5mm diameter,36cm long, 15mm curved coated blade and a clamp arm with tissue pad, capable of cutting, sealing, grasping and coagulating blood vessels up to and including 5mm in diameter, 360 degrees rotation, ergonomic handle compatible with ultrasonic energy source and capable of hand and foot activation |
| 50 | Advanced bipolar tissue sealer 25 cms, with 5mm shaft diameter, 24 mm Jaw length, 21.8 mm cut length and 13.4 mm Jaw aperture designed for use in open surgical procedures with curved and tapered tip and uses an advanced algorithm for intelligent and efficient energy delivery. Device to have intuitive design with separate Seal and Cut button and 360 degree continuous shaft rotation |
| 51 | Advanced bipolar tissue sealer 37 cms, with 5mm shaft diameter, 24 mm Jaw length, 21.8 mm cut length and 13.4 mm Jaw aperture designed for use in Laproscopic surgical procedures with curved and tapered tip and uses an advanced algorithm for intelligent and efficient energy delivery. Device to have intuitive design with separate Seal and Cut button and 360 degree continuous shaft rotation |
| 52 | Advanced bipolar tissue sealer 45 cms with 5mm shaft diameter, 24 mm Jaw length, 21.8 mm cut length and 13.4 mm Jaw aperture designed for use in Laproscopic surgical procedures with curved and tapered tip and uses an advanced algorithm for intelligent and efficient energy delivery. Device to have intuitive design with separate Seal and Cut button and 360 degree continuous shaft rotation |
| 53 | Laparoscopic shears 5mm diameter,36cm long, 18mm curved coated blade and a clamp arm with tissue pad, capable of cutting,sealing,grasping and coagulating blood vessels up to and including 7mm in diameter, 360 degrees rotation, advance hemostasis hand activation mode for sealing vessels upto 7mm in diameter ,ergonomic handle compatible with ultrasonic energy source, capable of hand and foot activation with an integrated hand piece and transducer. |
| 54 | Connecting cable for ultrasonic harmonic scalpel for Open Energy probes compatible with Focus Plus Shear- HP BLUE |
| 55 | Connecting cable for ultrasonic harmonic scalpel for Lap Energy probes compatible with Ace plus Shear HP054 |
| 56 | Laparoscopic shears 5mm diameter,45cm long, 15mm curved coated blade and a clamp arm with tissue pad, capable of cutting,sealing,grasping and coagulating blood vessels up to and including 7mm in diameter, 360 degrees rotation, advance hemostasis hand activation mode for sealing vessels upto 7mm in diameter, ergonomic handle compatible with ultrasonic energy source and capable of hand and foot activation |
| 57 | Nasal Haemostatic sponge Pack (With Airway) 10 inch |
| 58 | Platting for maxillary swing and mandibular fixation Surgeries (titanium) Plates - 2 mm thickness (2x2 ) hole Drill bit machine with insertion tools |
| 59 | Platting for maxillary swing and mandibular fixation Surgeries (titanium) Plates - 2 mm thickness (1x2) hole Drill bit machine with insertion tools |
| 60 | Platting for maxillary swing and mandibular fixation Surgeries (titanium) Plates - 2 mm thickness (1x1 ) hole Drill bit machine with insertion tools |
| 61 | Platting for maxillary swing and mandibular fixation Surgeries (titanium) Screw- (2 mm ) diameter Drill bit machine with insertion tools |
| 62 | Platting for maxillary swing and mandibular fixation Surgeries (titanium) Screw- (1.5 mm ) diameter Drill bit machine with insertion tools |
| 63 | Platting for maxillary swing and mandibular fixation Surgeries (titanium) Screw- (2.5 mm ) diameter Drill bit machine with insertion tools |
| 64 | Platting for maxillary swing and mandibular fixation Surgeries (titanium) Screw- (3 mm) diameter Drill bit machine with insertion tools |
| 65 | Speech Prosthesis for Laryngectomy (indwelling low resistance silicon voice prosthesis varied diameter with varied length should have blue teflon valve seet for primary and secondary insertion along with inserting tools and cleaning accessories) 17FR (4 mm) |
| 66 | Speech Prosthesis for Laryngectomy (indwelling low resistance silicon voice prosthesis varied diameter with varied length should have blue teflon valve seet for primary and secondary insertion along with inserting tools and cleaning accessories) 17FR (6 mm) |
| 67 | Speech Prosthesis for Laryngectomy (indwelling low resistance silicon voice prosthesis varied diameter with varied length should have blue teflon valve seet for primary and secondary insertion along with inserting tools and cleaning accessories) 17FR (8 mm) |
| 68 | Speech Prosthesis for Laryngectomy (indwelling low resistance silicon voice prosthesis varied diameter with varied length should have blue teflon valve seet for primary and secondary insertion along with inserting tools and cleaning accessories) 17FR (10 mm) |
| 69 | Speech Prosthesis for Laryngectomy (indwelling low resistance silicon voice prosthesis varied diameter with varied length should have blue teflon valve seet for primary and secondary insertion along with inserting tools and cleaning accessories) 17FR (12.5 mm) |
| 70 | Speech Prosthesis for Laryngectomy (indwelling low resistance silicon voice prosthesis varied diameter with varied length should have blue teflon valve seet for primary and secondary insertion along with inserting tools and cleaning accessories) 20Fr (4 mm) |
| 71 | Speech Prosthesis for Laryngectomy (indwelling low resistance silicon voice prosthesis varied diameter with varied length should have blue teflon valve seet for primary and secondary insertion along with inserting tools and cleaning accessories) 20Fr (6 mm) |
| 72 | Speech Prosthesis for Laryngectomy (indwelling low resistance silicon voice prosthesis varied diameter with varied length should have blue teflon valve seet for primary and secondary insertion along with inserting tools and cleaning accessories) 20Fr (8 mm) |
| 73 | Speech Prosthesis for Laryngectomy (indwelling low resistance silicon voice prosthesis varied diameter with varied length should have blue teflon valve seet for primary and secondary insertion along with inserting tools and cleaning accessories) 20Fr (10 mm) |
| 74 | Speech Prosthesis for Laryngectomy (indwelling low resistance silicon voice prosthesis varied diameter with varied length should have blue teflon valve seet for primary and secondary insertion along with inserting tools and cleaning accessories) 20Fr (12.5 mm) |
| 75 | Speech Prosthesis for Laryngectomy (indwelling low resistance silicon voice prosthesis varied diameter with varied length should have blue teflon valve seet for primary and secondary insertion along with inserting tools and cleaning accessories) 22.5FR (6 mm) |
| 76 | Speech Prosthesis for Laryngectomy (indwelling low resistance silicon voice prosthesis varied diameter with varied length should have blue teflon valve seet for primary and secondary insertion along with inserting tools and cleaning accessories) 22.5FR (8 mm) |
| 77 | Speech Prosthesis for Laryngectomy (indwelling low resistance silicon voice prosthesis varied diameter with varied length should have blue teflon valve seet for primary and secondary insertion along with inserting tools and cleaning accessories) 22.5FR (10 mm) |
| 78 | Speech Prosthesis for Laryngectomy (indwelling low resistance silicon voice prosthesis varied diameter with varied length should have blue teflon valve seet for primary and secondary insertion along with inserting tools and cleaning accessories) 22.5FR (12.5 mm) |
| 79 | Speech Prosthesis for Laryngectomy (indwelling low resistance silicon voice prosthesis varied diameter with varied length should have blue teflon valve seet for primary and secondary insertion along with inserting tools and cleaning accessories) 22.5FR (4 mm) |
| 80 | Block used in thyroplasty (Sialestic and gortex) 70x50 mm with 20 mm thickness |
| 81 | Disposable needle 16G x 1 inch |
| 82 | Curved tip & Stepped Cartridges face from inner to outer side 2.0,2.5 and 3.0 mm staple heights row for variable thickness tissue application , fixed anvil , different leg length staples in same cartridge , inbuilt knife ,size 45 mm tan colour code for vascular applications |
| 83 | Curved tip & Stepped Cartridges face from inner to outer side 3.0,3.5 and 4.0 mm staple heights row for variable thickness tissue application , fixed anvil , different leg length staples in same cartridge , inbuilt knife ,size 45 mm purpule colour code for medium to thick tissue |
| 84 | Varied Staple Height reloads/cartridges for 60 mm GIA instruments with Tri-Staple technology, with the cutting knife blade incorporated in the reloads itself, with black varied staple height of 4, 4.5 and 5mm leg length |
| 85 | Disposable laparoscopic Clip Applier Preloaded with 16 clips, 5mm diameter with Clip logic technology and digital display Titanium Clips- U shaped |
| 86 | Synthetic oxidised re-generated cellulose double layered with PEG and Trilysine size 2x4cm |
| 87 | Synthetic oxidised re-generated cellulose double layered with PEG and Trilysine size 5x10cm |
| 88 | Disposable 10 mm Endoscopic Clip Applier with facility of loading clips independent of the firing mechanism: medium/large size |
| 89 | Disposable 10 mm Endoscopic Clip Applier with facility of loading clips independent of the firing mechanism large size |
| 90 | Endo liner cutter without integrated fresh knife with 360*rotation & 0-45* articulation in both direction : for use with cartridges in sizes of 30mm, Capable of loading all length cartridges on same gun only |
| 91 | Endo liner cutter without integrated fresh knife with 360*rotation & 0-45* articulation in both direction : for use with cartridges in sizes of 45mm Capable of loading all length cartridges on same gun only |
| 92 | Endo liner cutter without integrated fresh knife with 360*rotation & 0-45* articulation in both direction : for use with cartridges in sizes of 60mm, Capable of loading all length cartridges on same gun only |
| 93 | Disposable Clip Applier Preloaded with 20 clips, superinterlock security with clip design technology Medium |
| 94 | Disposable Clip Applier Preloaded with 20 clips, superinterlock security with clip design technology Small |
| 95 | Sterile hypodermic syringe with needle attached, 22G, single use -2 ml |
| 96 | Sterile hypodermic syringe with needle attached, 22G, single use -5 ml |
| 97 | Biological glue with thrombin & aprotinin 1ml |
| 98 | Biological glue with thrombin & aprotinin 2ml |
| 99 | Close Wound Drainage Device Under Negative Pressure (Closed Wound Suction Unit) |
| 100 | Close Wound Drainage Device Under Negative Pressure (Closed Wound Suction Unit) |
| 101 | Close Wound Drainage Device Under Negative Pressure (Closed Wound Suction Unit) |
| 102 | Close Wound Drainage Device Under Negative Pressure (Closed Wound Suction Unit) |
| 103 | Sterile oxidized regenerated cellulose hemostating agent in netform fibrillar and in thick sheath As per IP |
| 104 | Urine collecting bag, disposable 2000 ml with Uroflow meter |
| 105 | Central neck line- double lumen (3 nobel metal coated (gold, silver, palladium)central lumen catheter, double Lumen) |
| 106 | Microcatheter Selective infusion microcatheters for intra cranial aneurysm treatment with 2 tip markers |
| 107 | Microcatheter Selective infusion microcatheters for deploying intracranial device: stent deployment |
| 108 | Microcatheter Selective infusion microcatheters for flow diverter delivery with single tip markers 0.027inch |
| 109 | Microcatheter Flow dependent Super-selective high flow infusion microcatheters for cerebral/spinal AVMs (compatible with DMSO) |
| 110 | MICRO GUIDE WIRE For microcatheter shapable distal end and with torque 0.014inch |
| 111 | Bare platinum coil complex shape, soft, electrolytic detachable framing and filling |
| 112 | Bare platinum coil complex shape, soft, mechanically detachable framing and filling |
| 113 | Bare platinum coil helical shape, soft, electrolytic detachable |
| 114 | Bare platinum coil helical shape, soft, mechanically detachable |
| 115 | AORTIC PUNCH 2.5 Length betwwen 6 to 7' Midlength Diamond edge sharp, dual cut edge for clean precise removal of aortic tissue, conical tip or round / eliptical tip for easy insertation by straight or button hole tech, should have long and short handle confirguaration, sterile packing |
| 116 | AORTIC PUNCH 3 Length betwwen 6 to 7' Midlength Diamond edge sharp, dual cut edge for clean precise removal of aortic tissue, conical tip or round / eliptical tip for easy insertation by straight or button hole tech, should have long and short handle confirguaration, sterile packing |
| 117 | AORTIC PUNCH 3.5 Length betwwen 6 to 7' Midlength Diamond edge sharp, dual cut edge for clean precise removal of aortic tissue, conical tip or round / eliptical tip for easy insertation by straight or button hole tech, should have long and short handle confirguaration, sterile packing |
| 118 | AORTIC PUNCH 4 Length betwwen 6 to 7' Midlength Diamond edge sharp, dual cut edge for clean precise removal of aortic tissue, conical tip or round / eliptical tip for easy insertation by straight or button hole tech, should have long and short handle confirguaration, sterile packing |
| 119 | AORTIC PUNCH 4.5 Length betwwen 6 to 7' Midlength Diamond edge sharp, dual cut edge for clean precise removal of aortic tissue, conical tip or round / eliptical tip for easy insertation by straight or button hole tech, should have long and short handle confirguaration, sterile packing |
| 120 | AORTIC PUNCH 5 Length betwwen 6 to 7' Midlength Diamond edge sharp, dual cut edge for clean precise removal of aortic tissue, conical tip or round / eliptical tip for easy insertation by straight or button hole tech, should have long and short handle confirguaration, sterile packing |
| 121 | AORTIC PUNCH 5.5 Length betwwen 6 to 7' Midlength Diamond edge sharp, dual cut edge for clean precise removal of aortic tissue, conical tip or round / eliptical tip for easy insertation by straight or button hole tech, should have long and short handle confirguaration, sterile packing |
| 122 | AORTIC PUNCH 3.6 Length betwwen 6 to 7' Midlength Diamond edge sharp, dual cut edge for clean precise removal of aortic tissue, conical tip or round / eliptical tip for easy insertation by straight or button hole tech, should have long and short handle confirguaration, sterile packing |
| 123 | Folley's Catheter Fixation divice Foley catheter holder universal Size should have leg band and is disposable single patiemnt use device should have catheter grip of 18 to 24 Fr catheter and made of Crobelt or any other. |
| 124 | TUR Set TUR irrigation Set disposable urology instrument urology equipment endosurgery, MFG from clinical grade non toxic medical transparent PVC sheet, Y Shaped Connector with pointed Spike to easy pierce facilities alternative change solution, thumb operated clamp smooth chnage of bottle, proximal end fitted with flexible latest tubing for easy connection to endoscope, ETO steril individual pack. should have minium Lenght of 260 cm or more. |
| 125 | LAPROSCOPIC PORT WITH TROCAR 5mm Optically guided bladeless trocar 5mm with bilateral tissue separators, optical tip to eliminate blind entry, clear ribbed cannula to enhance abdominal wall retention, recessed stopcock valve, funnel shaped housing, duckbill secondary seal, integrated universal seal that eliminates the use of reducer, 150mm length. |
| 126 | Programmable automatic bipsy Gun with compitible Co-axial needle Should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. Should have three programmable firing mode-Automatic mode, Delay mode and Zero throw mode. Should have two firing btton on surface of the gun, Size 12G, 14G, 16G, 18G, 20G with length 11cm, 15cm, 20cm. Should come with compitible coaxial packed with Biopsy Gun. USFDA Approved. |
| 127 | Programmable automatic bipsy Gun with compitible Co-axial needle Should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. Should have three programmable firing mode-Automatic mode, Delay mode and Zero throw mode. Should have two firing btton on surface of the gun, Size 12G, 14G, 16G, 18G, 20G with length 11cm, 15cm, 20cm. Should come with compitible coaxial packed with Biopsy Gun. USFDA Approved. |
| 128 | Programmable automatic bipsy Gun with compitible Co-axial needle Should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. Should have three programmable firing mode-Automatic mode, Delay mode and Zero throw mode. Should have two firing btton on surface of the gun, Size 12G, 14G, 16G, 18G, 20G with length 11cm, 15cm, 20cm. Should come with compitible coaxial packed with Biopsy Gun. USFDA Approved. |
| 129 | Programmable automatic bipsy Gun with compitible Co-axial needle Should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. Should have three programmable firing mode-Automatic mode, Delay mode and Zero throw mode. Should have two firing btton on surface of the gun, Size 12G, 14G, 16G, 18G, 20G with length 11cm, 15cm, 20cm. Should come with compitible coaxial packed with Biopsy Gun. USFDA Approved. |
| 130 | Programmable automatic bipsy Gun with compitible Co-axial needle Should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. Should have three programmable firing mode-Automatic mode, Delay mode and Zero throw mode. Should have two firing btton on surface of the gun, Size 12G, 14G, 16G, 18G, 20G with length 11cm, 15cm, 20cm. Should come with compitible coaxial packed with Biopsy Gun. USFDA Approved. |
| 131 | Programmable automatic bipsy Gun with compitible Co-axial needle Should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. Should have three programmable firing mode-Automatic mode, Delay mode and Zero throw mode. Should have two firing btton on surface of the gun, Size 12G, 14G, 16G, 18G, 20G with length 11cm, 15cm, 20cm. Should come with compitible coaxial packed with Biopsy Gun. USFDA Approved. |
| 132 | Programmable automatic bipsy Gun with compitible Co-axial needle Should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. Should have three programmable firing mode-Automatic mode, Delay mode and Zero throw mode. Should have two firing btton on surface of the gun, Size 12G, 14G, 16G, 18G, 20G with length 11cm, 15cm, 20cm. Should come with compitible coaxial packed with Biopsy Gun. USFDA Approved. |
| 133 | Programmable automatic bipsy Gun with compitible Co-axial needle Should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. Should have three programmable firing mode-Automatic mode, Delay mode and Zero throw mode. Should have two firing btton on surface of the gun, Size 12G, 14G, 16G, 18G, 20G with length 11cm, 15cm, 20cm. Should come with compitible coaxial packed with Biopsy Gun. USFDA Approved. |
| 134 | Programmable automatic bipsy Gun with compitible Co-axial needle Should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. Should have three programmable firing mode-Automatic mode, Delay mode and Zero throw mode. Should have two firing btton on surface of the gun, Size 12G, 14G, 16G, 18G, 20G with length 11cm, 15cm, 20cm. Should come with compitible coaxial packed with Biopsy Gun. USFDA Approved. |
| 135 | Programmable automatic bipsy Gun with compitible Co-axial needle Should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. Should have three programmable firing mode-Automatic mode, Delay mode and Zero throw mode. Should have two firing btton on surface of the gun, Size 12G, 14G, 16G, 18G, 20G with length 11cm, 15cm, 20cm. Should come with compitible coaxial packed with Biopsy Gun. USFDA Approved. |
| 136 | Programmable automatic bipsy Gun with compitible Co-axial needle Should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. Should have three programmable firing mode-Automatic mode, Delay mode and Zero throw mode. Should have two firing btton on surface of the gun, Size 12G, 14G, 16G, 18G, 20G with length 11cm, 15cm, 20cm. Should come with compitible coaxial packed with Biopsy Gun. USFDA Approved. |
| 137 | Programmable automatic bipsy Gun with compitible Co-axial needle Should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. Should have three programmable firing mode-Automatic mode, Delay mode and Zero throw mode. Should have two firing btton on surface of the gun, Size 12G, 14G, 16G, 18G, 20G with length 11cm, 15cm, 20cm. Should come with compitible coaxial packed with Biopsy Gun. USFDA Approved. |
| 138 | Programmable automatic bipsy Gun with compitible Co-axial needle Should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. Should have three programmable firing mode-Automatic mode, Delay mode and Zero throw mode. Should have two firing btton on surface of the gun, Size 12G, 14G, 16G, 18G, 20G with length 11cm, 15cm, 20cm. Should come with compitible coaxial packed with Biopsy Gun. USFDA Approved. |
| 139 | Programmable automatic bipsy Gun with compitible Co-axial needle Should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. Should have three programmable firing mode-Automatic mode, Delay mode and Zero throw mode. Should have two firing btton on surface of the gun, Size 12G, 14G, 16G, 18G, 20G with length 11cm, 15cm, 20cm. Should come with compitible coaxial packed with Biopsy Gun. USFDA Approved. |
| 140 | Programmable automatic bipsy Gun with compitible Co-axial needle Should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. Should have three programmable firing mode-Automatic mode, Delay mode and Zero throw mode. Should have two firing btton on surface of the gun, Size 12G, 14G, 16G, 18G, 20G with length 11cm, 15cm, 20cm. Should come with compitible coaxial packed with Biopsy Gun. USFDA Approved. |
| 141 | Patient pre operative skin prepration solution 26 ml in one step sterile applicator container for single use with 2% chlorohexdine gluconate (CHG) and 70% IPA with orange tint colour or easy visulization, US FDA Approved |
| 142 | REM and Non-REM single use, corded patient return electrodes conductive adhesive hydrogel with USFDA. |
| 143 | Chlorhexidine impregnated paraffin gauze 30x10 cm |
| 144 | Chlorhexidine impregnated paraffin 15 cm x 1 Roll |
| 145 | Surgical Gloves 6.5 Non Latex surgical gloves Synthetic Polyisoprene powder free overall length 283mm with Puncture Indicator technology USFDA Approved |
| 146 | Surgical Gloves 7 Non Latex surgical gloves Synthetic Polyisoprene powder free overall length 283mm with Puncture Indicator technology USFDA Approved |
| 147 | Surgical Gloves 7.5 Non Latex surgical gloves Synthetic Polyisoprene powder free overall length 283mm with Puncture Indicator technology USFDA Approved |
| 148 | Ionic Silver Dressings with Broad Spectrum Antimicrobial, Bactericidal, Biofilm destruction & reformation efficacies recommended for Low to High Exuding Wounds 5 Cms x 5 Cms |
| 149 | Ionic Silver Dressings with Broad Spectrum Antimicrobial, Bactericidal, Biofilm destruction & reformation efficacies recommended for Low to High Exuding Wounds 10 Cms x 10 Cms |
| 150 | Self Adherent Moist Wound Dressing made up of Triple Hydrocolloid Matrix,Elastomeric Polymer For Pressure Ulcers/Bed Sores 10 Cms x 10 Cms |
| 151 | Stich Bonded Hydrofiber Burns Dresssings with 1.2% Impregnated Ionic Silver with Sustained and on demand Broad Spectrum Antimicrobial & Bactricidal activity with High Exudate management capability with a Wear time of 21 Days & Locking in Edudates in Gel form 23 x 100 Cms |
| 152 | Double wall Resuscitator with PEEP valve in Adult It should be fully autoclavable double wall with hand strapIt should be supplied with autoclavable reservoir bagIt should have a single shutter valve system made of silicone rubberIt should have Easy attachment of PEEP valve for Adult Bag Volume: Mark IV (1300 ml) Weight: Adult (415 g) It should be US-FDA, CE & ISO certified |
| 153 | Double wall Resuscitator with PEEP valve in Paediatrics It should be fully autoclavable double wall with hand strapIt should be supplied with autoclavable reservoir bagIt should have a single shutter valve system made of silicone rubberIt should have Easy attachment of PEEP valve for PeadiatricIt should have provision to attach manometer for Paediatrics Ambu BagBag Volume: Mark IV Baby (300 ml) Weight: Baby (190 g) It should be US-FDA, CE & ISO certified |
| 154 | Single Patient Use SEBS Resuscitator (SPUR II with Peep Valve in Adult) • It should be single use resuscitator made to SEBS material not PVC.• It should have Unique single-shutter valve system for reliable functionality & Swivel between valve and mask permits 360° positioning in relation to the patient• It should have Thin-walled compression bag with hand strip.• Resuscitator volume: Adult (1475 ml)• (including reservoir and mask)• It should be CE/ISO, US FDA certified. |
| 155 | Single Patient Use SEBS Resuscitator (SPUR II with Peep Valve in Paed) • It should be single use resuscitator made to SEBS material not PVC.• It should have Unique single-shutter valve system for reliable functionality & Swivel between valve and mask permits 360° positioning in relation to the patient• It should have Thin-walled compression bag with hand strip.It should have provision to attach manometer for Paediatrics Ambu Bag.• Resuscitator volume: Pediatric (635 ml)• (including reservoir and mask)• It should be CE/ISO, US FDA certified. |
| 156 | Single Patient Use SEBS Resuscitator (SPUR II with Peep Valve in Neonatal) • It should be single use resuscitator made to SEBS material not PVC.• It should have Unique single-shutter valve system for reliable functionality & Swivel between valve and mask permits 360° positioning in relation to the patient• It should have Thin-walled compression bag with hand strip.• Resuscitator volume: Neonate(220ml)• (including reservoir and mask)• It should be CE/ISO, US FDA certified. |
| 157 | Pre-formed SGA with gastric access & Intubation It should be latex free preformed laryngeal mask having gastric access channel and should be used as a conduit for direct endotracheal intubation with any brand ETT• It should built-in, anatomically correct curve and cuff & tube moulded as a single unit.• Ultra-thin pilot balloon with tactile indication of degree of inflation.• Universal 15mm connector (ISO).• It should be CE/ISO, US FDA certified |
| 158 | Pre-formed SGA with gastric access & Intubation It should be latex free preformed laryngeal mask having gastric access channel and should be used as a conduit for direct endotracheal intubation with any brand ETT• It should built-in, anatomically correct curve and cuff & tube moulded as a single unit.• Ultra-thin pilot balloon with tactile indication of degree of inflation.• Universal 15mm connector (ISO).• It should be CE/ISO, US FDA certified |
| 159 | Pre-formed SGA with gastric access & Intubation It should be latex free preformed laryngeal mask having gastric access channel and should be used as a conduit for direct endotracheal intubation with any brand ETT• It should built-in, anatomically correct curve and cuff & tube moulded as a single unit.• Ultra-thin pilot balloon with tactile indication of degree of inflation.• Universal 15mm connector (ISO).• It should be CE/ISO, US FDA certified |
| 160 | Pre-formed SGA with gastric access & Intubation It should be latex free preformed laryngeal mask having gastric access channel and should be used as a conduit for direct endotracheal intubation with any brand ETT• It should built-in, anatomically correct curve and cuff & tube moulded as a single unit.• Ultra-thin pilot balloon with tactile indication of degree of inflation.• Universal 15mm connector (ISO).• It should be CE/ISO, US FDA certified |
| 161 | Pre-formed SGA with gastric access & Intubation It should be latex free preformed laryngeal mask having gastric access channel and should be used as a conduit for direct endotracheal intubation with any brand ETT• It should built-in, anatomically correct curve and cuff & tube moulded as a single unit.• Ultra-thin pilot balloon with tactile indication of degree of inflation.• Universal 15mm connector (ISO).• It should be CE/ISO, US FDA certified |
| 162 | Pre-formed SGA with gastric access & Intubation It should be latex free preformed laryngeal mask having gastric access channel and should be used as a conduit for direct endotracheal intubation with any brand ETT• It should built-in, anatomically correct curve and cuff & tube moulded as a single unit.• Ultra-thin pilot balloon with tactile indication of degree of inflation.• Universal 15mm connector (ISO).• It should be CE/ISO, US FDA certified |
| 163 | Pre-formed SGA with gastric access & Intubation It should be latex free preformed laryngeal mask having gastric access channel and should be used as a conduit for direct endotracheal intubation with any brand ETT• It should built-in, anatomically correct curve and cuff & tube moulded as a single unit.• Ultra-thin pilot balloon with tactile indication of degree of inflation.• Universal 15mm connector (ISO).• It should be CE/ISO, US FDA certified |
| 164 | Pre-formed SGA with gastric access & Intubation It should be latex free preformed laryngeal mask having gastric access channel and should be used as a conduit for direct endotracheal intubation with any brand ETT• It should built-in, anatomically correct curve and cuff & tube moulded as a single unit.• Ultra-thin pilot balloon with tactile indication of degree of inflation.• Universal 15mm connector (ISO).• It should be CE/ISO, US FDA certified |
| 165 | Silicone Pre-formed SGA • It should be and autoclavable up to 40 times• It should have reinforced tip at cuff and cuff & tube moulded as a single unit.• Atraumatic insertion and removal.• It should be CE/ISO, US FDA certified |
| 166 | Silicone Pre-formed SGA • It should be and autoclavable up to 40 times• It should have reinforced tip at cuff and cuff & tube moulded as a single unit.• Atraumatic insertion and removal.• It should be CE/ISO, US FDA certified |
| 167 | Silicone Pre-formed SGA Total size 8 • It should be and autoclavable up to 40 times• It should have reinforced tip at cuff and cuff & tube moulded as a single unit.• Atraumatic insertion and removal.• It should be CE/ISO, US FDA certified |
| 168 | Silicone Pre-formed SGA • It should be and autoclavable up to 40 times• It should have reinforced tip at cuff and cuff & tube moulded as a single unit.• Atraumatic insertion and removal.• It should be CE/ISO, US FDA certified |
| 169 | Silicone Pre-formed SGA • It should be and autoclavable up to 40 times• It should have reinforced tip at cuff and cuff & tube moulded as a single unit.• Atraumatic insertion and removal.• It should be CE/ISO, US FDA certified |
| 170 | Silicone Pre-formed SGA • It should be and autoclavable up to 40 times• It should have reinforced tip at cuff and cuff & tube moulded as a single unit.• Atraumatic insertion and removal.• It should be CE/ISO, US FDA certified |
| 171 | Silicone Pre-formed SGA • It should be and autoclavable up to 40 times• It should have reinforced tip at cuff and cuff & tube moulded as a single unit.• Atraumatic insertion and removal.• It should be CE/ISO, US FDA certified |
| 172 | Silicone Pre-formed SGA • It should be and autoclavable up to 40 times• It should have reinforced tip at cuff and cuff & tube moulded as a single unit.• Atraumatic insertion and removal.• It should be CE/ISO, US FDA certified |
| 173 | Cervical Collar with 12 Sizes Settings • It should be latex free adjustable collar with 12 size setting in paediatric collar • It should have standard Sizing line for easy and accurate sizing• It should be CE/ISO, US FDA certified |
| 174 | Cervical Collar with 16 Sizes Settings • It should be latex free adjustable collar with 16 size setting in adult collar • It should have standard Sizing line for easy and accurate sizing• It should be CE/ISO, US FDA certified |
| 175 | Offset Connector Cardio Sensor Electrodes • It should have high conductive wet gel to ensure reliable traces.• It should be design with offset connector to prevent artefacts from disrupting the readouts• It should have high quality Ag/AgCl sensor to ensure excellent trace quality• It should have size not more than 72 x 68 mm |
| 176 | Offset Connector Cardio Sensor Electrodes • It should have high conductive wet gel to ensure reliable traces.• It should be design with offset connector to prevent artefacts from disrupting the readouts• It should have high quality Ag/AgCl sensor to ensure excellent trace quality• It should have size not more than 72 x 68 mm |
| 177 | Offset Connector Cardio Sensor Electrodes • It should have high conductive wet gel to ensure reliable traces.• It should be design with offset connector to prevent artefacts from disrupting the readouts• It should have high quality Ag/AgCl sensor to ensure excellent trace quality• It should have size not more than 72 x 68 mm |
| 178 | Anatomical Face mask with thumb rest Silicone •Thumb rest for a tight, easy seal, made up of Silicone |
| 179 | Anatomical Face mask with thumb rest Silicone •Thumb rest for a tight, easy seal, made up of Silicone• Can be autoclaved repeatedly at 134°C |
| 180 | Anatomical Face mask with thumb rest Silicone •Thumb rest for a tight, easy seal, made up of Silicone • Can be autoclaved repeatedly at 134°C |
| 181 | Anatomical Face mask with thumb rest Silicone •Thumb rest for a tight, easy seal, made up of Silicone • Can be autoclaved repeatedly at 134°C |
| 182 | Anatomical Face mask with thumb rest Silicone •Thumb rest for a tight, easy seal, made up of Silicone • Can be autoclaved repeatedly at 134°C |
| 183 | Anatomical Face mask with thumb rest Silicone •Thumb rest for a tight, easy seal, made up of Silicone • Can be autoclaved repeatedly at 134°C |
| 184 | Anatomical Face mask with thumb rest Silicone •Thumb rest for a tight, easy seal, made up of Silicone • Can be autoclaved repeatedly at 134°C |
| 185 | Disposable SGA Anatomical Curve • It should have special curve that carefully replicates natural human anatomy• It Moulded directly into the tube• Should have a D-shaped airway tube to give a firm and ergonomically grip during insertion |
| 186 | Disposable SGA Anatomical Curve • It should have special curve that carefully replicates natural human anatomy• It Moulded directly into the tube• Should have a D-shaped airway tube to give a firm and ergonomically grip during insertion |
| 187 | Disposable SGA Anatomical Curve • It should have special curve that carefully replicates natural human anatomy• It Moulded directly into the tube• Should have a D-shaped airway tube to give a firm and ergonomically grip during insertion |
| 188 | Disposable SGA Anatomical Curve • It should have special curve that carefully replicates natural human anatomy• It Moulded directly into the tube• Should have a D-shaped airway tube to give a firm and ergonomically grip during insertion |
| 189 | Disposable SGA Anatomical Curve • It should have special curve that carefully replicates natural human anatomy• It Moulded directly into the tube• Should have a D-shaped airway tube to give a firm and ergonomically grip during insertion |
| 190 | Disposable SGA Anatomical Curve • It should have special curve that carefully replicates natural human anatomy• It Moulded directly into the tube• Should have a D-shaped airway tube to give a firm and ergonomically grip during insertion |
| 191 | Disposable SGA Anatomical Curve • It should have special curve that carefully replicates natural human anatomy• It Moulded directly into the tube• Should have a D-shaped airway tube to give a firm and ergonomically grip during insertion |
| 192 | Disposable SGA Anatomical Curve • It should have special curve that carefully replicates natural human anatomy• It Moulded directly into the tube• Should have a D-shaped airway tube to give a firm and ergonomically grip during insertion |
| 193 | Rhinolaryngo Single Patient Use Slim Scope Insertion tube diameter : 3.0mm.working length: 300 mmBending range : 130 degree up & 130 degree downField of view : 85 degree or moreDirection of View : 0 degree (Forward view)Depth of Field : 6-50 mm or better Complete system should be US-FDA and European CE certified |
| 194 | Rhinolaryngo Single Patient Use Invtervention Scope Channel width : 2.2mmInsertion tube diameter : 5.0 mm.working length : 350 mmBending range :130 degree up & 130 degree down Field of view : 85 degree or more Direction of View : 0 degree (Forward view) Depth of Field : 6-50 mm or betterComplete system should be US-FDA and European CE certified |
| 195 | ULTRASORBS AP DISPOSABLE DRYPADS, Dry pad for moisture management, 58.4x90cm, with breathable layer, super absorbent core, aqua shield film and air permeable back sheet, Absorbency of 1800-2300gm, USFDA/CE/BIS compliant, ISO13485 compliant |
| 196 | ELASTIC HEAD STRAP CANNULAS Pediatric ELASTIC HEAD STRAP CANNULAS Pediatric must be Soft siliconised, transparent vinyl; Adjustable elastic band for comfortable, snug fit below the ears; Complete kit with 7-ft oxygen supply tubing. Manufacturer must be US-FDA registered & certified with EN/EU ISO 13485 & applicable 510K & CE certification. |
| 197 | Over-the-Ear Nasal Cannula Over-the-Ear Nasal Cannula with Star Lumen, 50' Tubing, must be Flexible contoured lip tab provides a high level of stability and patient comfort. Over-the-ear design for a comfortable and secure fit, Crush- and kink-resistant tubing. Manufacturer must be US-FDA registered & certified with EN/EU ISO 13485 & applicable 510K & CE certification. |
| 198 | Pediatric Nasal Cannula Pediatric Nasal Cannula Softech with Universal Oxygen Connector, 7' Star-Lumen Tubing Lightweight, flexible nasal cannula with standard over-the-ear designed that optimizes fit and stability, Soft nasal prongs help maximize patient comfort. Individually packaged for convenience and sterility. Manufacturer must be US-FDA registered & certified with EN/EU ISO 13485 & applicable 510K & CE certification. |
| 199 | Infant Nasal Cannula Infant Nasal Cannula Softech with Universal Oxygen Connector, 7' Star-Lumen Tubing Lightweight, flexible nasal cannula with standard over-the-ear designed that optimizes fit and stability, Soft nasal prongs to help maximize patient comfort. Individually packaged for convenience and sterility. Manufacturer must be US-FDA registered & certified with EN/EU ISO 13485 & applicable 510K & CE certification. |
| 200 | Volumetric Incentive Spirometer (ADULT) Volumetric Incentive Spirometer (ADULT) 4000 mL with Handle. Volume measurement must be compact comfortable designed to accommodate large inspired volumes. Must have Good-Better-Best flow window & Advanced, low work-of-breathing design. Particulate filter screen in device housing must help to reduce risk of foreign matter passing to patients. Expandable and collapsible tube must help patients find comfortable position for treatments and can be removed when storing the device. Ergonomic swiveled mouthpiece allows to patients create tight seal to enable more accurate measurement. Flow indicator with smiley face provides visual target for desired inhalation and bright green flow indicator make it easy for patients to see results. Manufacturer must be US-FDA registered & certified with EN/EU ISO 13485 & applicable 510K & CE certification. |
| 201 | Volumetric Incentive Spirometer (PEDIATRIC) Volumetric Incentive Spirometer (PEDIATRIC) 2500 mL with Handle. Volume measurement must be compact comfortable designed to accommodate large inspired volumes. Must have Good-Better-Best flow window & Advanced, low work-of-breathing design. Particulate filter screen in device housing must help to reduce risk of foreign matter passing to patients. Expandable and collapsible tube must help patients find comfortable position for treatments and can be removed when storing the device. Ergonomic swiveled mouthpiece allows to patients create tight seal to enable more accurate measurement. Flow indicator with smiley face provides visual target for desired inhalation and bright green flow indicator make it easy for patients to see results. Manufacturer must be US-FDA registered & certified with EN/EU ISO 13485 & applicable 510K & CE certification. |
| 202 | Inspiratory Exerciser with 3 color-coded balls, 3 chambers Inspiratory Exerciser with 3 color-coded balls, 3 chambers & Wide flow rate range from 600 to 1200 cc/sec, with Minimum flow imprinted on each chamber. Must be Compact design and made of break-resistant plastic. Manufacturer must be US-FDA registered & certified with EN/EU ISO 13485 & applicable 510K & CE certification. |
| 203 | Adult Mask For tracheostomy Adult Mask For tracheostomy and laryngectomy aerosol therapy Tubing connector must swivels 360° for ease of positioning; 22 mm OD connector accepts 22 mm, corrugated tubing and nebulizer tees. Manufacturer must be US-FDA registered & certified with EN/EU ISO 13485 & applicable 510K & CE certification. |
| 204 | Pardiatric Mask For tracheostomy Pediatric Mask For tracheostomy and laryngectomy aerosol therapy Tubing connector must swivels 360° for ease of positioning; 22 mm OD connector accepts 22 mm, corrugated tubing and nebulizer tees. Manufacturer must be US-FDA registered & certified with EN/EU ISO 13485 & applicable 510K & CE certification. |
| 205 | Elongated Aerosol Mask Adult Elongated Aerosol Mask Adult with Under-the-chin design for excellent fit on wide range of face sizes must be Clear, soft vinyl for patient comfort; Adjustable nose clip assures comfortable fit; Specifically designed for aerosol therapy; must be with supplied with 6 ft. Corr A Flex Corrugated Tubing, featuring cuttable sections every 6 in. Manufacturer must be US-FDA registered & certified with EN/EU ISO 13485 & applicable 510K & CE certification. |
| 206 | Elongated Aerosol Mask Pediatric Elongated Aerosol Mask Pediatric with Under-the-chin design for excellent fit on wide range of face sizes must be Clear, soft vinyl for patient comfort; Adjustable nose clip assures comfortable fit; Specifically designed for aerosol therapy; must be with supplied with 6 ft. Corr A Flex Corrugated Tubing, featuring cuttable sections every 6 in. Manufacturer must be US-FDA registered & certified with EN/EU ISO 13485 & applicable 510K & CE certification. |
| 207 | Elongated three-in-one Adult mask Elongated three-in-one Adult mask must be able to use as a medium-concentration, high-concentration or nonrebreathing mask which Includes mask with flapper valve, nonrebreathing bag assembly; Adjustable nose clip assures comfortable fit; with 7 ft. Star Lumen Oxygen Supply Tubing; 750 mL reservoir bag. Manufacturer must be US-FDA registered & certified with EN/EU ISO 13485 & applicable 510K & CE certification. |
| 208 | Adult Conventional Single Water Trap Adult Conventional Single Water Trap (non-heated) Ventilator Circuits are available in a variety of different configurations and styles.To incorporate standard connectors for use with a variety of ventilators, Ported wyes allow pressure sensing and temperature monitoring and include tethered caps, All adult conventional circuits with 72 in. long, Standard ventilator circuit with Straight connector inspiratory limb water Trap (for use with HMEs only). Manufacturer must be US-FDA registered & certified with EN/EU ISO 13485 & applicable 510K & CE certification. |
| 209 | Adult Ventilator Circuit Single Limb Portable Adult Ventilator Circuit with Universal single limb. Must be Complete Kit with main circuit hose, exhalation valve manifold, aerosol hose, patient elbow connector, proximal airway pressure line, exhalation valve line, and humidifier limb. Manufacturer must be US-FDA registered & certified with EN/EU ISO 13485 & applicable 510K & CE certification. |
| 210 | Adult Ventilator Circuit Single Water Trap Adult Conventional Single Water Trap (non-heated) Ventilator Circuits are available in a variety of different configurations and styles.To incorporate standard connectors for use with a variety of ventilators, Ported wyes allow pressure sensing and temperature monitoring and include tethered caps, All adult conventional circuits with 72 in. long, Standard ventilator circuit with Straight connector inspiratory limb water Trap (for use with HMEs only). Manufacturer must be US-FDA registered & certified with EN/EU ISO 13485 & applicable 510K & CE certification. |
| 211 | Adult Conventional Dual limb Water Trap Adult Conventional Dual limb Water Trap (non-heated) Ventilator Circuits are available in a variety of different configurations and styles.To incorporate standard connectors for use with a variety of ventilators, Ported wyes allow pressure sensing and temperature monitoring and include tethered caps, All adult conventional circuits with 72 in. long, Standard ventilator circuit with Straight connector Dual limb Inspiratory & expiratory Water Trap 22mm tubing, (for use with HMEs only). Manufacturer must be US-FDA registered & certified with EN/EU ISO 13485 & applicable 510K & CE certification. |
| 212 | Infant Prong CPAP cannula Infant Prong CPAP cannula Nasal Size 0 with designed to reduce trauma associated with delivery of infant nasal CPAP. Must be Soft siliconised, anatomically curved prongs to enhance fit. Luer fitting on expiratory connector to allow proximal airway pressure monitoring. Each set to include, Soft Siliconised Cannula; Inspiratory & Expiratory elbow connector; Knit cap; Two 6 in. hook and loop fastener sections; Two 10 to 7.5 mm adaptors. Manufacturer must be US-FDA registered & certified with EN/EU ISO 13485 & applicable 510K & CE certification. |
| 213 | FHME Heat and moisture exchangers with Bacteria viral filters Bacterial Filtration efficiency> 99.99% and Viral Filtration Efficiency > 99.9999% .Filter membrane should be of a hydrophobic non-woven polypropylene material.Should be tailored to meet the specific needs of both anaesthesia and intensive care. |
| 214 | Tracheostomy HME: 1 Heat and moisture exchangers for spontaneously breathing tracheotomy patients.2 Should have in built oxygen port.3 Should be compact & light wt.4 Should be suitable for ambulatory patients, Sampling and suctioning can be done without removing it.5 The system should have kink resisting oxygen tubing |
| 215 | Double lumen Endobronchial tube left: Size-28Fr Low pressure tracheal and bronchial cuffs to minimise risk of mucosal damage. Color coded bronchial cuff, bronchial proximal lumen and bronchial pilot balloon assists in location of tube and tip when verification is confirmed by fiberoptic bronchoscope.X-ray opaque markers at distal tip above bronchial cuff and at tracheal opening for verification of tube position. |
| 216 | Double lumen Endobronchial tube left: Size-32Fr Low pressure tracheal and bronchial cuffs to minimise risk of mucosal damage. Color coded bronchial cuff, bronchial proximal lumen and bronchial pilot balloon assists in location of tube and tip when verification is confirmed by fiberoptic bronchoscope.X-ray opaque markers at distal tip above bronchial cuff and at tracheal opening for verification of tube position. |
| 217 | Double lumen Endobronchial tube left: Size-35Fr Low pressure tracheal and bronchial cuffs to minimise risk of mucosal damage. Color coded bronchial cuff, bronchial proximal lumen and bronchial pilot balloon assists in location of tube and tip when verification is confirmed by fiberoptic bronchoscope.X-ray opaque markers at distal tip above bronchial cuff and at tracheal opening for verification of tube position. |
| 218 | Double lumen Endobronchial tube left: Size-37Fr Low pressure tracheal and bronchial cuffs to minimise risk of mucosal damage. Color coded bronchial cuff, bronchial proximal lumen and bronchial pilot balloon assists in location of tube and tip when verification is confirmed by fiberoptic bronchoscope.X-ray opaque markers at distal tip above bronchial cuff and at tracheal opening for verification of tube position. |
| 219 | Double lumen Endobronchial tube left: Size-39Fr Low pressure tracheal and bronchial cuffs to minimise risk of mucosal damage. Color coded bronchial cuff, bronchial proximal lumen and bronchial pilot balloon assists in location of tube and tip when verification is confirmed by fiberoptic bronchoscope.X-ray opaque markers at distal tip above bronchial cuff and at tracheal opening for verification of tube position. |
| 220 | Double lumen Endobronchial tube left: Size-41Fr Low pressure tracheal and bronchial cuffs to minimise risk of mucosal damage. Color coded bronchial cuff, bronchial proximal lumen and bronchial pilot balloon assists in location of tube and tip when verification is confirmed by fiberoptic bronchoscope.X-ray opaque markers at distal tip above bronchial cuff and at tracheal opening for verification of tube position. |
| 221 | Double lumen endobronchial tube right: Size-35FrLow pressure tracheal and bronchial cuffs to minimize risk of mucosal damage.Color coded bronchial cuff, bronchial proximal lumen and bronchial pilot balloon assists inlocation of tube and tip when verification is confirmed by fibreoptic bronchoscope.X-ray opaque markers at distal tip above bronchial cuff and at tracheal opening for verification of tube position. |
| 222 | Double lumen endobronchial tube right: Size-37FrLow pressure tracheal and bronchial cuffs to minimize risk of mucosal damage.Color coded bronchial cuff, bronchial proximal lumen and bronchial pilot balloon assists inlocation of tube and tip when verification is confirmed by fibreoptic bronchoscope.X-ray opaque markers at distal tip above bronchial cuff and at tracheal opening for verification of tube position. |
| 223 | Double lumen endobronchial tube right: Size-39FrLow pressure tracheal and bronchial cuffs to minimize risk of mucosal damage.Color coded bronchial cuff, bronchial proximal lumen and bronchial pilot balloon assists inlocation of tube and tip when verification is confirmed by fibreoptic bronchoscope.X-ray opaque markers at distal tip above bronchial cuff and at tracheal opening for verification of tube position. |
| 224 | Sub-glottic Tube TAPER GUARD EVAC: sizes 6mmThe tube should have an additional lumen integrated into the wall of the tube to allow suctioning of subglottic space. Should have Cuff in Taper Size to prevent Micro aspiration Should have Low volume/low pressure cuff. |
| 225 | Sub-glottic Tube TAPER GUARD EVAC: sizes 6.5mmThe tube should have an additional lumen integrated into the wall of the tube to allow suctioning of subglottic space. Should have Cuff in Taper Size to prevent Micro aspiration Should have Low volume/low pressure cuff. |
| 226 | Sub-glottic Tube TAPER GUARD EVAC: sizes 7mmThe tube should have an additional lumen integrated into the wall of the tube to allow suctioning of subglottic space. Should have Cuff in Taper Size to prevent Micro aspiration Should have Low volume/low pressure cuff. |
| 227 | Sub-glottic Tube TAPER GUARD EVAC: sizes 7.5mmThe tube should have an additional lumen integrated into the wall of the tube to allow suctioning of subglottic space. Should have Cuff in Taper Size to prevent Micro aspiration Should have Low volume/low pressure cuff. |
| 228 | Sub-glottic Tube TAPER GUARD EVAC: sizes 8mmThe tube should have an additional lumen integrated into the wall of the tube to allow suctioning of subglottic space. Should have Cuff in Taper Size to prevent Micro aspiration Should have Low volume/low pressure cuff. |
| 229 | Sub-glottic Tube TAPER GUARD EVAC: sizes 8.5mmThe tube should have an additional lumen integrated into the wall of the tube to allow suctioning of subglottic space. Should have Cuff in Taper Size to prevent Micro aspiration Should have Low volume/low pressure cuff. |
| 230 | Sub-glottic Tube TAPER GUARD EVAC: sizes 9mmThe tube should have an additional lumen integrated into the wall of the tube to allow suctioning of subglottic space. Should have Cuff in Taper Size to prevent Micro aspiration Should have Low volume/low pressure cuff. |
| 231 | Inflation Device Inflation device in 30atm & 20ml with clear polycarbonate barrel for easy visualisation of bubbles, luminescent dial, airless rotator, lock release handle for easy one-handed control and primelok for easy preparation.USFDA Approvedq |
| 232 | Manifold Manifolds in 2, 3, 5 Port with configuration of left-right orientation, On-OFF handle, full-half body, 200 PSI-500 PSI rating and wide port spacing. Should have clear polycarbonate body to provide durability and visibility, airless rotator and large bore inner lumen throughout including rotator.USFDA Approved |
| 233 | High Pressure Tube High pressure tubing in 25cm with Braided, flexible tubing of polyurethane rated 1200 PSI. USFDA Approved |
| 234 | High Pressure Tube High pressure tubing in 51cm with Braided, flexible tubing of polyurethane rated 1200 PSI. USFDA Approved |
| 235 | High Pressure Tube High pressure tubing in 76,cm with Braided, flexible tubing of polyurethane rated 1200 PSI. USFDA Approved |
| 236 | High Pressure Tube High pressure tubing in 122,cm with Braided, flexible tubing of polyurethane rated 1200 PSI. USFDA Approved |
| 237 | High Pressure Tube High pressure tubing in 183cm with Braided, flexible tubing of polyurethane rated 1200 PSI. USFDA Approved |
| 238 | Torque Device Torque Device for .014\\" to .038\\" standard and hydrophilic guide wires with squeeze-load-release mechanism.USFDA Approved |
| 239 | Radial Band Radial hemostatis band in 24 cm . Curved backer plat with large area& clear unobstructed site visibility, convinient tubing clip with two check valve options and device stickers. Should be available with standard luer and specialized connection syringe. US FDA Approved |
| 240 | Radial Band Radial hemostatis band in 29 cm. Curved backer plat with large area & clear unobstructed site visibility, convinient tubing clip with two check valve options and device stickers. Should be available with standard luer and specialized connection syringe. US FDA Approved |
| 241 | Angiography Needle Angiography needle in 18G, length of 2-9cm. Should be available in echo enhanced & smooth finish, ergonomic hub with bevel orientation point, silicone coated stainless steel to reduce needle drag and superior sharpness to facilitate entry into tissue and vessel wall. USFDA Approved |
| 242 | Angiography Needle Angiography needle in 19G, length of 2-9cm. Should be available in echo enhanced & smooth finish, ergonomic hub with bevel orientation point, silicone coated stainless steel to reduce needle drag and superior sharpness to facilitate entry into tissue and vessel wall. USFDA Approved |
| 243 | Angiography Needle Angiography needle in 20G, length of 2-9cm. Should be available in echo enhanced & smooth finish, ergonomic hub with bevel orientation point, silicone coated stainless steel to reduce needle drag and superior sharpness to facilitate entry into tissue and vessel wall. USFDA Approved |
| 244 | Angiography Needle Angiography needle in 21G, length of 2-9cm. Should be available in echo enhanced & smooth finish, ergonomic hub with bevel orientation point, silicone coated stainless steel to reduce needle drag and superior sharpness to facilitate entry into tissue and vessel wall. USFDA Approved |
| 245 | Angiography Wire PTFE Guidewire in .035\\", .038\\", in regular length. Should have 3mm J-tip, Straight tip, PRE-COATING for smooth surface with less friction, finger straight-able with precise J-Tip memory and packed in flush hoop with J Straightener. Should have option of fixed core, movable core, heparin coating, 1.5mm J-tip. USFDA Approved |
| 246 | Angiography Wire Long Length PTFE Guidewire in .035\\", .038\\", with exchange length. Should have 3mm J-tip, Straight tip, PRE-COATING for smooth surface with less friction, finger straight-able with precise J-Tip memory and packed in flush hoop with J Straightener. Should have option of fixed core, movable core, heparin coating, 1.5mm J-tip. USFDA Approved |
| 247 | Amplatz Wire PTFE Amplatz type wire in .035 and .038, length of 75cm, 145cm, 180cm. Should be available in multiple flexible tip length of 1.0cm, 3.5cm, 4.0cm, 6cm, 7cm and J 3.0mm. USFDA Approved. USFDA Approved |
| 248 | Hydrophilic wire Hydrophilic guidewire of .018\\", .025\\", .035\\", .038\\" in 80cm, 150cm with straight, angled tip. Should come in stiff & standard configuration, nitinol core polyurethane jacket hydrophilic coated guide wires with radiopaque jacket for enhanced visibility, hydrated gel coating and true 1:1 torque. USFDA Approved |
| 249 | Hydrophilic Wire Long Length Hydrophilic guidewire of .018\\", .025\\", .035\\", .038\\" in 180cm, 220cm, 260cm length with straight, angled tip. Should come in stiff & standard configuration, nitinol core polyurethane jacket hydrophilic coated guide wires with radiopaque jacket for enhanced visibility, hydrated gel coating and true 1:1 torque. USFDA Approved |
| 250 | Hydrophillic Braided Sheath Hydrophilic Braided Sheath Introducer in 4F to 7F, length of 7, 11, 16, 23cm with the option of .018\\", .021\\", .025\\" plastic jacketed and spring coil guidewire. Should have ultra-thin wall and flat wire braiding technology to provide support and low profile.USFDA Approved |
| 251 | Femoral Sheath with Needle Femoral sheath in 5F to 8F, length of 11-23cm with puncher needle of 18g and guidewire of .035\\", .038\\". Should have rotating suture ring, snap-fit dilator to prevent slipping during insertion and holster pack. Should be available in polypropylene. USFDA Approved |
| 252 | Angiography Catheter Diagnostic Catheter in 4F-6F, length of 70-110cm & 125cm , Should come in various shapes & curve length including JL & JR (1.5, 2, 2.5, 3, 3.5, 4, 4.5, 5, 6 cm), AL, AR, Tig, MP, IM, Sones, Pigtail (straight, Angle, Radial). Should have flat wire braiding, nylon material, thin wall design for higher flow rates, radio-opaque tip, strain relief and winged polycarbonate hub. Should be available in various configurations- braided, non braided, short tip, bumper tip, sideholes as applicable. USFDA Approved |
| 253 | Angiography Radial Catheters Diagnostic Radial Catheter with Radial Ultimate Curve in 4-6F. Lenght of 100cm, 110cm, 125cm. Should have four type of Radial ultimate curves. Should have flat wire braiding, nylon material, thin wall design for higher flow rates, radio-opaque tip, strain relief and winged polycarbonate hub. US FDA Approved |
| 254 | One loop & Triple Loop Snare Snare kit(2-35mm diameter, 90-degree nitinol & gold-plated tungsten loop) and Multiloop snare kit(2-45mm diameter, three interlaced nitinol loops) for foreign body retrieval, should come with flexible, reinforced, strain relief hub to reduce buckling and unique peel away insertion tool. USFDA Approved |
| 255 | PTCA Kit (1) Three Port manifold with knobs to turn\\"Right\\" when open (2) One pressure line, (3) fluid connecting line, (4) contrast connecting line, (5) one three way stop cock, (6) one Y-connector hemoststic valve with spring type push and release mechanism, (7) one inflation device with manometer upto 30 atm (easy to operate with luminescent dial), (8) one luer lock controlled syringe of 10 ml with finger grip, (9) Insertion needle, (10) torque device.USFDA Approved |
| 256 | Closed Suction Catheter for Paediatrics Number and color- coded graduations for controlled depth suctioning.Separate Y connectors available for different tubes in the pack.Catheter is made up of medical grade Silicon Material.sizes are 5fr. |
| 257 | Closed Suction Catheter for Paediatrics Number and color- coded graduations for controlled depth suctioning.Separate Y connectors available for different tubes in the pack.Catheter is made up of medical grade Silicon Material. sizes are 6fr |
| 258 | Closed Suction Catheter for Paediatrics Number and color- coded graduations for controlled depth suctioning.Separate Y connectors available for different tubes in the pack.Catheter is made up of medical grade Silicon Material. sizes are 7fr. |
| 259 | Closed Suction Catheter for Paediatrics Number and color- coded graduations for controlled depth suctioning.Separate Y connectors available for different tubes in the pack.Catheter is made up of medical grade Silicon Material.sizes 8fr. |
| 260 | Closed Suction Catheter for Paediatrics Number and color- coded graduations for controlled depth suctioning.Separate Y connectors available for different tubes in the pack.Catheter is made up of medical grade Silicon Material.sizes are 10fr. |
| 261 | Closed Suction Catheter for Paediatrics Number and color- coded graduations for controlled depth suctioning.Separate Y connectors available for different tubes in the pack.Catheter is made up of medical grade Silicon Material. sizes 12fr. |
| 262 | Paediatric Endotracheal Tube Paediatric Microcuff designed according to the paediatric anatomy.Cuff is made up of Polyurethane,Thickness of Cuff is 10 microns.Microcuff seals at an average cuff pressure of 11 cmH2o.Burst pressure of Cuff is 805cmH2o.Anatomically based intubation depth marking with precision bands.Cuff with play mode function. sizes are 3mm. |
| 263 | Paediatric Endotracheal Tube Paediatric Microcuff designed according to the paediatric anatomy.Cuff is made up of Polyurethane,Thickness of Cuff is 10 microns.Microcuff seals at an average cuff pressure of 11 cmH2o.Burst pressure of Cuff is 805cmH2o.Anatomically based intubation depth marking with precision bands.Cuff with play mode function. sizes are 3.5mm. |
| 264 | Paediatric Endotracheal Tube Paediatric Microcuff designed according to the paediatric anatomy.Cuff is made up of Polyurethane,Thickness of Cuff is 10 microns.Microcuff seals at an average cuff pressure of 11 cmH2o.Burst pressure of Cuff is 805cmH2o.Anatomically based intubation depth marking with precision bands.Cuff with play mode function. sizes are 5.5mm |
| 265 | Adult Endotracheal Tube Cuff is made up of Polyurethane.Thickness of Cuff is 10 microns.Microcuff seals at an average cuff pressure of 20 cmH2o.Burst pressure of Cuff is 800cmH2o.Cuff with play mode function. sizes 5.5mm. |
| 266 | Adult Endotracheal Tube Cuff is made up of Polyurethane.Thickness of Cuff is 10 microns.Microcuff seals at an average cuff pressure of 20 cmH2o.Burst pressure of Cuff is 800cmH2o.Cuff with play mode function. sizes 10mm. |
| 267 | KIMVENT BAL CATH Non Bronchoscopic BAL for Bronchial Aspirate Sampling. Can be performed in minutes at bedside. Directional Tip allows right or left lung sampling.Maintains PEEP when used with supplied ventilator adapter. Soft, cushioned, radiopaque tip for safe sampling. Protected with outer Catheter Covering. t size 13fr . |
| 268 | KIMVENT BAL CATH Non Bronchoscopic BAL for Bronchial Aspirate Sampling. Can be performed in minutes at bedside. Directional Tip allows right or left lung sampling.Maintains PEEP when used with supplied ventilator adapter. Soft, cushioned, radiopaque tip for safe sampling. Protected with outer Catheter Covering. sizes 16fr. |
| 269 | Disposable Spo2 Sensor It Should be base on original Nellcor technology with Original Oximax Technology |
| 270 | Catheter Mount Double Swivel Connector, It Should have bronchoscopy port . It sholud be approved by US FDA |
| 271 | Gastrostomy Feeding Tube Medical Grade Silicone Construction.Low Profile Design.Tapered Distal tip,Silicone Internal Retention Balloon.Distal Tip Recessed at 5m.lProximal Anti Reflux Valve.Secur Lok Extention Set Connector Mechanism,Radiopaque Stripe,Gamma Sterilized Size – 12,Length (0.8 – 5.0) |
| 272 | Gastrostomy Feeding Tube Medical Grade Silicone Construction.Low Profile Design.Tapered Distal tip,Silicone Internal Retention Balloon.Distal Tip Recessed at 5m.lProximal Anti Reflux Valve.Secur Lok Extention Set Connector Mechanism,Radiopaque Stripe,Gamma SterilizedSize – 14 Length (0.8 – 5.0) |
| 273 | Gastrostomy Feeding Tube Medical Grade Silicone Construction.Low Profile Design.Tapered Distal tip,Silicone Internal Retention Balloon.Distal Tip Recessed at 5m.lProximal Anti Reflux Valve.Secur Lok Extention Set Connector Mechanism,Radiopaque Stripe,Gamma SterilizedSize – 16 Length (0.8 – 5.0) |
| 274 | Gastrostomy Feeding Tube Medical Grade Silicone Construction.Low Profile Design.Tapered Distal tip,Silicone Internal Retention Balloon.Distal Tip Recessed at 5m.lProximal Anti Reflux Valve.Secur Lok Extention Set Connector Mechanism,Radiopaque Stripe,Gamma SterilizedSize – 18,Length (0.8 – 5.0) |
| 275 | Gastrostomy Feeding Tube Medical Grade Silicone Construction.Low Profile Design.Tapered Distal tip,Silicone Internal Retention Balloon.Distal Tip Recessed at 5m.lProximal Anti Reflux Valve.Secur Lok Extention Set Connector Mechanism,Radiopaque Stripe,Gamma SterilizedSize – 20 Length (0.8 – 5.0) |
| 276 | Gastrostomy Feeding Tube Medical Grade Silicone Construction.Low Profile Design.Tapered Distal tip,Silicone Internal Retention Balloon.Distal Tip Recessed at 5m.lProximal Anti Reflux Valve.Secur Lok Extention Set Connector Mechanism,Radiopaque Stripe,Gamma Sterilized Size – 24fr Length (0.8 – 5.0) |
| 277 | PERCUTANEOUS ENDOSCOPIC GASTROSTOMY (PEG) Medical Grade Silicone Construction.External Retention Ring .Universal And Bolus feeding Port connectors,Medication Port.Collapsible Internal Retention Bumper.Radiopaque Stripe and Bumper.Tubing clamp.ETO sterilized.Sizes – 14fr |
| 278 | PERCUTANEOUS ENDOSCOPIC GASTROSTOMY (PEG) Medical Grade Silicone Construction.External Retention Ring .Universal And Bolus feeding Port connectors,Medication Port.Collapsible Internal Retention Bumper.Radiopaque Stripe and Bumper.Tubing clamp.ETO sterilized.Sizes – 20fr |
| 279 | PERCUTANEOUS ENDOSCOPIC GASTROSTOMY (PEG) Medical Grade Silicone Construction.External Retention Ring .Universal And Bolus feeding Port connectors,Medication Port.Collapsible Internal Retention Bumper.Radiopaque Stripe and Bumper.Tubing clamp.ETO sterilized.Sizes – 24fr |
| 280 | Silk protein based sterile surgical PU Foam Dressing Non Adhesive Biomodified, silk protein based, sterile, soft, conformable, absorbent, double layered polyurethene foam dressing comprised of Silk protein 8% and Asiaticoside NLT 0.6%, with super fluid handling capacity, decreases the risk of maceration,sterlization-Gamma sterlized |
| 281 | Silk protein & antimicrobial nanosilver based sterile surgical PU Foam Dressing Non Adhesive Biomodified, silk protein & silver impregnated, soft, conformable, absorbent, double layered polyurethene foam dressing comprised of Silk protein 8%, Asiaticoside NLT 0.6% and Silver 1.2%, with super fluid handling capacity, decreases the risk of maceration,sterlization-Gamma sterlized |
| 282 | Silk protein & antimicrobial Silver based sterile surgical mesh wound Dressing Biomodified, bilaminated silk protein and silver wound dressing with mesh pores to facilitate the easy drainage of exudates, comprised of activated silk matrix 46% and Asiaticoside NLT 0.6% and,sterlization-Gamma sterlizedSilver :1.2%. Non- Adhesive, square / rectangular in shape,sterlization-Gamma sterlized |
| 283 | Silk protein & antimicrobial nanosilver based sterile surgical wound Dressing sheet Biomodified, Bilaminated Silk Protein & Silver based surgical wound dressing comprised of Activated Silk matrix 46% and Asiaticoside 0.6% and Silver :1.2%. Non- Adhesive, square / rectangular in shape,sterlization-Gamma sterlized |
| 284 | Silk protein derived sterile surgical meshed wound Dressing Biomodified, Bilaminated Silk protein wound dressing with mesh pores to facilitate the easy drainage of exudates, comprised of Activated Silk matrix 46% and Asiaticoside NLT 0.6%. Non- Adhesive dressing, square / rectangular in shape,sterlization-Gamma sterlized |
| 285 | Silk protein Based sterile surgical wound dressing sheet Biomodified, Bilaminated silk protein wound dressing comprised of Activated Silk matrix 46% and Asiaticoside NLT 0.6%. Non- Adhesive dressing, square / rectangular shape,sterlization-Gamma sterlized |
| 286 | Silk protein Based antimicrobial wound healing ointment loaded with asiaticoside and silver Biomodified silk protein and silver based wound healing ointment comprised of Silk powder 8% , Asiaticoside NLT 0.6% and Silver:1.2%,sterlization-Gamma sterlized |
| 287 | Silk protein and nanosilver based microbicidal sterile surgical wound dressing Sprinkling powder Bottle Biomodified silk protein and silver based microbicidal sprinkling powder,comprised of Silk powder 8%, Asiaticoside NLT 0.6% and Silver :1.2% . Conforms to any wound shape and size, easy to apply,sterlization-Gamma sterlized |
| 288 | Silk protein based sterile surgical wound dressing Sprinkling powder Bottle Biomodified silk protein based wound healing sprinkling powder,comprised of Silk powder 8% and Asiaticoside NLT 0.6% . Conforms to any wound shape and size, easy to apply,sterlization-Gamma sterlized |
| 289 | Centella asiatica extract based skin moisturization and antiscar gel Centella asiatica extract based skin moisturization and antiscar gel, comprised of centella asiatica extract, glycerol and vitamin E.,sterlization-Gamma sterlized |
| 290 | Silk protein based sterile surgical particle wound dressingBiomodified, bioabsorbable Silk Protein and collagen containing particle wound dressing, comprised of Silk powder 8% , Asiaticoside 0.6% and collagen ,having natural moisturizing factor(NMF), suitable for cavity wound and any kind of slow and non- healing wound,sterlization-Gamma sterlized |
| 291 | Silk protein and antimicrobial nanosilver based sterile surgical particle wound dressing 5ml Biomodified, bioabsorbable Silk Protein, Collagen and Silver containing broadspectrum antimicrobial particle wound dressing ,comprised of Silk powder 8%, Asiaticoside 0.6% ,having natural moisturizing factor(NMF), suitable for deep, tunneling cavity wound or any kind of slow and non- healing wound,sterlization-Gamma sterlized |
| 292 | Silk protein and antimicrobial nanosilver based sterile surgical particle wound dressing 10ml Biomodified, bioabsorbable Silk Protein, Collagen and Silver containing broadspectrum antimicrobial particle wound dressing ,comprised of Silk powder 8%, Asiaticoside 0.6% ,having natural moisturizing factor(NMF), suitable for deep, tunneling cavity wound or any kind of slow and non- healing wound,sterlization-Gamma sterlized |
| 293 | Silk protein based non-woven backed with pad & self adhesive border, water-repellent sterile surgical dressing 10x20cm, Silk protein and nanocrystalline silver based highly conformable sterile antimicrobial dressing with adhesive backing and absorbent layer ,sterlization-Gamma sterlized |
| 294 | Silk protein based non-woven backed with pad & self adhesive border, water-repellent sterile surgical dressing 10x25cm, Silk protein and nanocrystalline silver based highly conformable sterile antimicrobial dressing with adhesive backing and absorbent layer ,sterlization-Gamma sterlized |
| 295 | Silk protein based non-woven backed with pad & self adhesive border, water-repellent sterile surgical dressing 15x15cm Silk protein and nanocrystalline silver based highly conformable sterile antimicrobial dressing with adhesive backing and absorbent layer ,sterlization-Gamma sterlized |
| 296 | Silk protein and PU foam pad with self adhesive border, water-proof dressing for post-operative scar or any scar management 10x20cm , Silk protein based highly conformable sterile PU foam with antiscarring properties and adhesive backin,sterlization-Gamma sterlized |
| 297 | Silk protein and PU foam pad with self adhesive border, water-proof dressing for post-operative scar or any scar management 10x25cm , Silk protein based highly conformable sterile PU foam with antiscarring properties and adhesive backin,sterlization-Gamma sterlized |
| 298 | Silk protein and PU foam pad with self adhesive border, water-proof dressing for post-operative scar or any scar management 10x21.5cm s Silk protein based highly conformable sterile PU foam with antiscarring properties and adhesive backin,sterlization-Gamma sterlized |
| 299 | Silk protein, nanosilver and asiaticoside based PU film backed with pad & self adhesive border, water-proof sterile surgical dressing 9x21.5cm Silk protein, nanocrystalline silver & asiaticoside based highly conformable sterile antimicrobial surgical and scar free wound healing dressing with adhesive backing and absorbent layer,sterlization-Gamma sterlized |
| 300 | Silk protein, nanosilver and asiaticoside based PU film backed with pad & self adhesive border, water-proof sterile surgical dressing 10x25cm Silk protein, nanocrystalline silver & asiaticoside based highly conformable sterile antimicrobial surgical and scar free wound healing dressing with adhesive backing and absorbent layer,sterlization-Gamma sterlized |
| 301 | Silk protein and antimicrobial nanosilver impregnated non-adherent leno gauze sterile surgical wound dressing 10x10cm . Silk protein & Nanocrystalline silver based sterile, non-adherent, antimicrobial gauze dressing ,sterlization-Gamma sterlized |
| 302 | Silk protein and antimicrobial nanosilver impregnated non-adherent leno gauze sterile surgical wound dressing 10x25cm . Silk protein & Nanocrystalline silver based sterile, non-adherent, antimicrobial gauze dressing ,sterlization-Gamma sterlized |
| 303 | Silk protein impregnated non-adherent leno gauze sterile primary surgical wound dressing 10x10cm Silk protein based sterile, non-adherent, antimicrobial gauze dressing ,sterlization-Gamma sterlized |
| 304 | Silk protein impregnated non-adherent leno gauze sterile primary surgical wound dressing 10x25cm . Silk protein based sterile, non-adherent, antimicrobial gauze dressing ,sterlization-Gamma sterlized |
| 305 | Papain-Urea & Silk Protein based wound debriding ointment and cream 25gm Papain-Urea based debriding ointment and cream for removal of necrotic tissue and slough in infected wounds, containing Papain IP : >521700 units and Urea IP : 100mg |
| 306 | Papain-Urea & Silk Protein based wound debriding ointment and cream 50gm Papain-Urea based debriding ointment and cream for removal of necrotic tissue and slough in infected wounds, containing Papain IP : >521700 units and Urea IP : 100mg |
| 307 | Silk protein, Asiaticoside and Povidone Iodine based broad spectrum topical antiseptic and antimicrobial wound healing ointment 25gm Broad spectrum antiseptic and antimicrobial topical ointment containing Povidone iodine USP: 5% w/w, Silk Protein, Centella asiatica for prevention of skin and wound infections. |
| 308 | Silk protein, Asiaticoside and Povidone Iodine based broad spectrum topical antiseptic and antimicrobial wound healing ointment 50Gm Broad spectrum antiseptic and antimicrobial topical ointment containing Povidone iodine USP: 5% w/w, Silk Protein, Centella asiatica for prevention of skin and wound infections. |
| 309 | Anti microbial gloves |
| 310 | ANTERIOR CHAMBER IOL PMMA material, single pieceKelman multiflex design5-6 mm optic size with 12-13 mm overall size Biconvex Power range +12 to +24Should be ISO or CE certified. Manufacturer should be asked to sample for approval. |
| 311 | CAPSULAR TENSION RING Standard capsular tension ringPMMA material with one eyelet each at each end 10 mm to 12 mm overall diameter sterile should be ISO/CE certified mfg. |
| 312 | IRIS HOOKS /RETRACTORS Set of five disposable sterile iris hooks with soft silicon stopper sterile Peek should be made PMMA ISO/CE certified Mfg. |
| 313 | Silicone Rod for Ptosis Repair Implantable flexible silicon rod attached to malleable sharp needles with a silicon sleeve. NeedleLength 60-70mm Diameter 920 µ length of silicone rod 40Cm, length of silicon sleeve 0.7 mm. |
| 314 | Reusable Anaesthetia Face mask of silicone Autocalvable & Pure Transparent. US FDA Approved and size should be mentioned on mask. |
| 315 | Reusable Anaesthetia Face mask of silicone Autocalvable & Pure Transparent. US FDA Approved and size should be mentioned on mask. |
| 316 | Reusable Anaesthetia Face mask of silicone Autocalvable & Pure Transparent. US FDA Approved and size should be mentioned on mask. |
| 317 | Reusable Anaesthetia Face mask of silicone Autocalvable & Pure Transparent. US FDA Approved and size should be mentioned on mask. |
| 318 | Reusable Anaesthetia Face mask of silicone Autocalvable & Pure Transparent. US FDA Approved and size should be mentioned on mask. |
| 319 | Reusable Anaesthetia Face mask of silicone Autocalvable & Pure Transparent. US FDA Approved and size should be mentioned on mask. |
| 320 | Flow Regulator Extension Set Flow rate 2ml to 350ml per hour |
| 321 | Sterile disposable hypodermic Needle No. 18x1½\\" |
| 322 | Sterile disposable hypodermic Needle No. 21x1½\\" |
| 323 | Sterile disposable hypodermic Needle No. 23x1½\\" |
| 324 | Neonatal Single Heated Wire Breathing System with auto Fill humidification chamber in Sterile Pack and US FDA Approved. Should be Compatible every humidifier. |
| 325 | Paed. Single Heated Wire Breathing System with auto Fill humidification chamber in Sterile Pack and US FDA Approved. Should be Compatible every humidifier. |
| 326 | Adult Single Heated Wire Breathing System with auto Fill humidification chamber in Sterile Pack and US FDA Approved. Should be Compatible every humidifier. |
| 327 | Neonatal High Flow Nasal Cannula having 8 litre flow. Should have soft tip . |
| 328 | PUR-XRO catheter 20 cm, 28G/1FR Picc Line with Stylet, Splitting Needle with securing wings with 8 cm extension tubing (Flow rate 1ml/min) |
| 329 | PUR-XRO catheter 30 cm, 24G/2FR Picc Line with Split Cannula And 10cm extension tubing over catheter (Flow Rate 0.2ml/min) |
| 330 | Dead body Bag 7x3 ft size leak proof material PP closed on all other sides and zipped on front or on 3 sides |
| 331 | INTRODUCER SHEATH WITH PUNCTURE NEEDLE FOR ADULTS US FDA APPROVED• 10-11 cm long• Pack must include 18 G, 6-7.5 cm long puncture needle: 0.035 or 0.038 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• Integral side port with attached 3-way stopcock• With suture eye for securing sheath• Kink resistant•With dilator-hub lock mechanism to prevent its back-out during insertion•With smooth and resistance free insertion |
| 332 | INTRODUCER SHEATH WITH PUNCTURE NEEDLE FOR ADULTS US FDA APPROVED• 10-11 cm long• Pack must include 18 G, 6-7.5 cm long puncture needle: 0.035 or 0.038 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• Integral side port with attached 3-way stopcock• With suture eye for securing sheath• Kink resistant• With dilator-hub lock mechanism to prevent its back-out during insertion• With smooth and resistance free insertion |
| 333 | INTODUCER SHEATH FOR ADULTS (size 10 Fr..)(Standard Length) US FDA APPROVED US FDA + CE/ DGCI Approved• 10-11 cm long• 0.035 or 0.038 inch guide wire compatible•With haemostatic valve to prevent back leak and air aspiration• Integral side port with attached 3-way stopcock• With suture eye for securing sheath• Kink resistant• With dilator-hub lock mechanism to prevent its back-out during insertion• With smooth and resistance free insertion US FDA + CE/ DGCI APPROVED |
| 334 | INTODUCER SHEATH FOR ADULTS (size 11 Fr.)(Standard Length) US FDA APPROVED US FDA + CE/ DGCI Approved• 10-11 cm long• 0.035 or 0.038 inch guide wire compatible•With haemostatic valve to prevent back leak and air aspiration• Integral side port with attached 3-way stopcock• With suture eye for securing sheath• Kink resistant• With dilator-hub lock mechanism to prevent its back-out during insertion• With smooth and resistance free insertionUS FDA + CE/ DGCI APPROVED |
| 335 | LONG INTRODUCER SHEATH (20-30 cm long) (Size 5Fr..) US FDA + CE/ DGCI APPROVED• Sheath should be between 20-30 cm long• 0.035 or 0.038 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• Integral side port with attached 3-way stopcock• With suture eye for securing sheath• Kink resistant• With dilator-hub lock mechanism to prevent its back-out during insertion• With smooth and resistance free insertion |
| 336 | LONG INTRODUCER SHEATH (20-30 cm long) (Size 6Fr.) US FDA + CE/ DGCI APPROVED• Sheath should be between 20-30 cm long• 0.035 or 0.038 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• Integral side port with attached 3-way stopcock• With suture eye for securing sheath• Kink resistant • With dilator-hub lock mechanism to prevent its back-out during insertion• With smooth and resistance free insertion |
| 337 | LONG INTRODUCER SHEATH (20-30 cm long) (Size 7Fr.) US FDA + CE/ DGCI APPROVED• Sheath should be between 20-30 cm long• 0.035 or 0.038 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• Integral side port with attached 3-way stopcock• With suture eye for securing sheath• Kink resistant • With dilator-hub lock mechanism to prevent its back-out during insertion• With smooth and resistance free insertion |
| 338 | LONG INTRODUCER SHEATH (20-30 cm long) (Size 8Fr) US FDA + CE/ DGCI APPROVED• Sheath should be between 20-30 cm long• 0.035 or 0.038 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• Integral side port with attached 3-way stopcock• With suture eye for securing sheath• Kink resistant • With dilator-hub lock mechanism to prevent its back-out during insertion• With smooth and resistance free insertion |
| 339 | LONG INTRODUCER SHEATH (20-30 cm long) (Size 9Fr.) US FDA + CE/ DGCI APPROVED• Sheath should be between 20-30 cm long• 0.035 or 0.038 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• Integral side port with attached 3-way stopcock• With suture eye for securing sheath• Kink resistant • With dilator-hub lock mechanism to prevent its back-out during insertion• With smooth and resistance free insertion |
| 340 | LONG INTRODUCER SHEATH (20-30 cm long)(Size 10Fr..) US FDA + CE/ DGCI APPROVED• Sheath should be between 20-30 cm long• 0.035 or 0.038 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• Integral side port with attached 3-way stopcock• With suture eye for securing sheath• Kink resistant • With dilator-hub lock mechanism to prevent its back-out during insertion• With smooth and resistance free insertion |
| 341 | LONG INTRODUCER SHEATH (20-30 cm long)(Size 11Fr.) US FDA + CE/ DGCI APPROVED• Sheath should be between 20-30 cm long• 0.035 or 0.038 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• Integral side port with attached 3-way stopcock• With suture eye for securing sheath• Kink resistant• With dilator-hub lock mechanism to prevent its back-out during insertion• With smooth and resistance free insertion |
| 342 | TRANS RADIAL INTRODUCER SHEETHS 4F US FDA + CE/ DGCI APPROVED• Sizes 4 French 10-20 cm long• Pack must include 18 G,-21 G, 6-7.5 cm long puncture needle• 0.025 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• Integral side port with attached 3-way stopcock• With suture eye for securing sheath• Kink resistant • With dilator-hub lock mechanism to prevent its back-out during insertion• With smooth and resistance free insertion |
| 343 | TRANS RADIAL INTRODUCER SHEETHS 5F US FDA + CE/ DGCI APPROVED• Sizes 5 French 10-20 cm long• Pack must include 18 G,-21 G, 6-7.5 cm long puncture needle• 0.025 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• Integral side port with attached 3-way stopcock• With suture eye for securing sheath• Kink resistant • With dilator-hub lock mechanism to prevent its back-out during insertion• With smooth and resistance free insertion |
| 344 | TRANS RADIAL INTRODUCER SHEETHS 6F US FDA + CE/ DGCI APPROVED• Sizes 6 French 10-20 cm long• Pack must include 18 G,-21 G, 6-7.5 cm long puncture needle• 0.025 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• Integral side port with attached 3-way stopcock• With suture eye for securing sheath• Kink resistant• With dilator-hub lock mechanism to prevent its back-out during insertion• With smooth and resistance free insertion |
| 345 | STEERABLE INTRODUCER SHEETHS 5F US FDA + CE/ DGCI APPROVED• Size 55 to 90 cms• To provide greater access to reaching target With ergonomic handle design• Movable Tip for different curves and torquability to ready Vessel |
| 346 | STEERABLE INTRODUCER SHEETHS 6FR US FDA + CE/ DGCI APPROVED• Size 55 to 90 cms• To provide greater access to reaching target With ergonomic handle design• Movable Tip for different curves and torquability to ready Vessel |
| 347 | STEERABLE INTRODUCER SHEETHS 7F US FDA + CE/ DGCI APPROVED• Size 55 to 90 cms• To provide greater access to reaching target With ergonomic handle design• Movable Tip for different curves and torquability to ready Vessel |
| 348 | STEERABLE INTRODUCER SHEETHS 8FUS FDA + CE/ DGCI APPROVED• Size 55 to 90 cms•To provide greater access to reaching target With ergonomic handle design• Movable Tip for different curves and torquability to ready Vessel |
| 349 | STEERABLE INTRODUCER SHEETHS 9F US FDA + CE/ DGCI APPROVED• Size 55 to 90 cms• To provide greater access to reaching target With ergonomic handle design• Movable Tip for different curves and torquability to ready Vessel |
| 350 | STEERABLE INTRODUCER SHEETHS 10F US FDA + CE/ DGCI APPROVED• Size 55 to 90 cms• To provide greater access to reaching target With ergonomic handle design• Movable Tip for different curves and torquability to ready Vessel |
| 351 | STEERABLE INTRODUCER SHEETHS 11F US FDA + CE/ DGCI APPROVED• Size 55 to 90 cms• To provide greater access to reaching target With ergonomic handle design• Movable Tip for different curves and torquability to ready Vessel |
| 352 | STEERABLE INTRODUCER SHEETHS 12F US FDA + CE/ DGCI APPROVED•Size 55 to 90 cms• To provide greater access to reaching target With ergonomic handle design• Movable Tip for different curves and torquability to ready Vessel |
| 353 | LONG BRADED INTRODUCER SHEATH – US FDA APPROVED US FDA + CE/ DGCI APPROVED• Should be 90 cm and above• 0.021 or 0.025 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• With integral side port with attached 3-way stopcock• With suture eye for securing sheath• Kink resistant• With dilator-hub lock mechanism to prevent its back-out during insertion |
| 354 | LONG BRADED INTRODUCER SHEATH – US FDA APPROVED US FDA + CE/ DGCI APPROVED•Should be 90 cm and above• 0.021 or 0.025 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• With integral side port with attached 3-way stopcock• With suture eye for securing sheath• Kink resistant• With dilator-hub lock mechanism to prevent its back-out during insertion |
| 355 | LONG BRADED INTRODUCER SHEATH – US FDA APPROVED US FDA + CE/ DGCI APPROVED•Should be 90 cm and above• 0.021 or 0.025 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• With integral side port with attached 3-way stopcock• With suture eye for securing sheath• Kink resistant• With dilator-hub lock mechanism to prevent its back-out during insertion |
| 356 | LONG BRADED INTRODUCER SHEATH – US FDA APPROVED US FDA + CE/ DGCI APPROVED•Should be 90 cm and above• 0.021 or 0.025 inch guide wire compatible•With haemostatic valve to prevent back leak and air aspiration• With integral side port with attached 3-way stopcock• With suture eye for securing sheath• Kink resistant• With dilator-hub lock mechanism to prevent its back-out during insertion |
| 357 | LONG BRADED CONTRA LATERAL INTRODUCER SHEATH US FDA + CE/ DGCI APPROVED•Should be 20 - 90 cm and above• 0.021 or 0.025 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• With integral side port with attached 3-way stopcock• With suture eye for securing sheath• Kink resistant• With dilator-hub lock mechanism to prevent its back-out during insertionq |
| 358 | LONG BRADED CONTRA LATERAL INTRODUCER SHEATH US FDA + CE/ DGCI APPROVED•Should be 20 - 90 cm and above• 0.021 or 0.025 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• With integral side port with attached 3-way stopcock• With suture eye for securing sheath• Kink resistant• With dilator-hub lock mechanism to prevent its back-out during insertion |
| 359 | LONG BRADED CONTRA LATERAL INTRODUCER SHEATH US FDA + CE/ DGCI APPROVED•Should be 20 - 90 cm and above• 0.021 or 0.025 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• With integral side port with attached 3-way stopcock• With suture eye for securing sheath• Kink resistant• With dilator-hub lock mechanism to prevent its back-out during insertion |
| 360 | LONG BRADED CONTRA LATERAL INTRODUCER SHEATH US FDA + CE/ DGCI APPROVED•Should be 20 - 90 cm and above• 0.021 or 0.025 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• With integral side port with attached 3-way stopcock• With suture eye for securing sheath• Kink resistant• With dilator-hub lock mechanism to prevent its back-out during insertion |
| 361 | LONG INTRODUCER SHEATH (30-50 cm long) (Size 5Fr..) US FDA + CE/ DGCI APPROVED•Between 30-50 cm long• 0.035 or 0.038 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• Integral side port with attached 3-way stopcock• Kink resistant• With dilator-hub lock mechanism to prevent its back-out during insertion• With smooth and resistance free insertion |
| 362 | LONG INTRODUCER SHEATH (30-50 cm long) (Size 6 Fr..) US FDA + CE/ DGCI APPROVED•Between 30-50 cm long• 0.035 or 0.038 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• Integral side port with attached 3-way stopcock• Kink resistant• With dilator-hub lock mechanism to prevent its back-out during insertion• With smooth and resistance free insertion |
| 363 | LONG INTRODUCER SHEATH (30-50 cm long) (Size 7Fr.) US FDA + CE/ DGCI APPROVED•Between 30-50 cm long• 0.035 or 0.038 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• Integral side port with attached 3-way stopcock• Kink resistant• With dilator-hub lock mechanism to prevent its back-out during insertion• With smooth and resistance free insertion |
| 364 | LONG INTRODUCER SHEATH (30-50 cm long) (Size 8Fr.) US FDA + CE/ DGCI APPROVED• Between 30-50 cm long• 0.035 or 0.038 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• Integral side port with attached 3-way stopcock• Kink resistant• With dilator-hub lock mechanism to prevent its back-out during insertion• With smooth and resistance free insertion |
| 365 | LONG INTRODUCER SHEATH (30-50 cm long) (Size 9Fr.) US FDA + CE/ DGCI APPROVED• Between 30-50 cm long• 0.035 or 0.038 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• Integral side port with attached 3-way stopcock• Kink resistant• With dilator-hub lock mechanism to prevent its back-out during insertion• With smooth and resistance free insertion |
| 366 | LONG INTRODUCER SHEATH (30-50 cm long)(Size 10Fr..) US FDA + CE/ DGCI APPROVED• Between 30-50 cm long• 0.035 or 0.038 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• Integral side port with attached 3-way stopcock• Kink resistant• With dilator-hub lock mechanism to prevent its back-out during insertion• With smooth and resistance free insertion |
| 367 | LONG INTRODUCER SHEATH (30-50 cm long)(Size 11Fr.) US FDA + CE/ DGCI APPROVED• Between 30-50 cm long• 0.035 or 0.038 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• Integral side port with attached 3-way stopcock• Kink resistant• With dilator-hub lock mechanism to prevent its back-out during insertion• With smooth and resistance free insertion |
| 368 | LONG INTRODUCER SHEATH DEDICATED FOR TRANSRADIAL ACCESS US FDA + CE/ DGCI APPROVED• Between 7-11 cm long• 0.021 or 0.025 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• Integral side port with attached 3-way stopcock• With suture eye for securing sheath• Kink resistant• With dilator-hub lock mechanism to prevent its back-out during insertion• With smooth and resistance free insertion |
| 369 | LONG INTRODUCER SHEATH DEDICATED FOR TRANSRADIAL ACCESS US FDA + CE/ DGCI APPROVED•Between 7-11 cm long • 0.021 or 0.025 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• Integral side port with attached 3-way stopcock• With suture eye for securing sheath• Kink resistant • With dilator-hub lock mechanism to prevent its back-out during insertion• With smooth and resistance free insertion |
| 370 | LONG INTRODUCER SHEATH DEDICATED FOR TRANSRADIAL ACCESS US FDA + CE/ DGCI APPROVED•Between 7-11 cm long• 0.021 or 0.025 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• Integral side port with attached 3-way stopcock• With suture eye for securing sheath• Kink resistant• With dilator-hub lock mechanism to prevent its back-out during insertion• With smooth and resistance free insertion |
| 371 | LONG INTRODUCER SHEATH DEDICATED FOR TRANSRADIAL ACCESS US FDA + CE/ DGCI APPROVED•Between 7-11 cm long• 0.021 or 0.025 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• Integral side port with attached 3-way stopcock• With suture eye for securing sheath• Kink resistant• With dilator-hub lock mechanism to prevent its back-out during insertion• With smooth and resistance free insertion |
| 372 | LONG INTRODUCER SHEATH US FDA + CE/ DGCI APPROVED• Should be 90 cm and above• 0.021 or 0.025 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• With integral side port with attached 3-way stopcock• With suture eye for securing sheath• Kink resistant• With dilator-hub lock mechanism to prevent its back-out during insertion |
| 373 | LONG INTRODUCER SHEATH US FDA + CE/ DGCI APPROVED• Should be 90 cm and above• 0.021 or 0.025 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• With integral side port with attached 3-way stopcock• With suture eye for securing sheath• Kink resistant• With dilator-hub lock mechanism to prevent its back-out during insertion |
| 374 | LONG INTRODUCER SHEATH US FDA + CE/ DGCI APPROVED• Should be 90 cm and above• 0.021 or 0.025 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• With integral side port with attached 3-way stopcock• With suture eye for securing sheath• Kink resistant• With dilator-hub lock mechanism to prevent its back-out during insertion |
| 375 | LONG INTRODUCER SHEATH US FDA + CE/ DGCI APPROVED• Should be 90 cm and above• 0.021 or 0.025 inch guide wire compatible• With haemostatic valve to prevent back leak and air aspiration• With integral side port with attached 3-way stopcock• With suture eye for securing sheath• Kink resistant• With dilator-hub lock mechanism to prevent its back-out during insertion |
| 376 | PTFE COATED DIAGNOSTIC GUIDE WIRE – (REGULAR LENGTH, REGULAR STIFFNESS) US FDA + CE/ DGCI APPROVED· Should be available in 0.025 inches size· Should be between 145-180 cm long· Should be available as straight & J-Shaped tip· Should be available in variable lengths of flexible/floppy end· Should be available in variable J tip sizes· Should be available fixed as well as movable core. |
| 377 | PTFE COATED DIAGNOSTIC GUIDE WIRE – (REGULAR LENGTH, REGULAR STIFFNESS) US FDA + CE/ DGCI APPROVED· Should be available in 0.032 inches size· Should be between 145-180 cm long· Should be available as straight & J-Shaped tip· Should be available in variable lengths of flexible/floppy end· Should be available in variable J tip sizes· Should be available fixed as well as movable core. |
| 378 | PTFE COATED DIAGNOSTIC GUIDE WIRE – (REGULAR LENGTH, REGULAR STIFFNESS) US FDA + CE/ DGCI APPROVED· Should be available in 0.035 size· Should be between 145-180 cm long· Should be available as straight & J-Shaped tip· Should be available in variable lengths of flexible/floppy end· Should be available in variable J tip sizes· Should be available fixed as well as movable core. |
| 379 | PTFE COATED DIAGNOSTIC GUIDE WIRE – (REGULAR LENGTH, REGULAR STIFFNESS) US FDA + CE/ DGCI APPROVED· Should be available in 0.038 inches size· Should be between 145-180 cm long· Should be available as straight & J-Shaped tip· Should be available in variable lengths of flexible/floppy end· Should be available in variable J tip sizes· Should be available fixed as well as movable core. |
| 380 | PTFE COATED DIAGNOSTIC GUIDE WIRE – (EXCHANGE LENGTH, REGULAR STIFFNESS) US FDA + CE/ DGCI APPROVED· Should be available in 0.025 inches size· Should be 240-300 cm long· Should be available as straight or J-Shaped tip· Should be available fixed as well as movable core. |
| 381 | PTFE COATED DIAGNOSTIC GUIDE WIRE – (EXCHANGE LENGTH, REGULAR STIFFNESS) US FDA + CE/ DGCI APPROVED· Should be available in 0.032, inches size· Should be 240-300 cm long· Should be available as straight or J-Shaped tip· Should be available fixed as well as movable core. |
| 382 | PTFE COATED DIAGNOSTIC GUIDE WIRE – (EXCHANGE LENGTH, REGULAR STIFFNESS) US FDA + CE/ DGCI APPROVED· Should be available in , 0.035 Inches size· Should be 240-300 cm long· Should be available as straight or J-Shaped tip· Should be available fixed as well as movable core. |
| 383 | PTFE COATED DIAGNOSTIC GUIDE WIRE – (EXCHANGE LENGTH, REGULAR STIFFNESS) US FDA + CE/ DGCI APPROVED· Should be available in 0.038 inches size· Should be 240-300 cm long· Should be available as straight or J-Shaped tip· Should be available fixed as well as movable core. |
| 384 | PTFE COATED DIAGNOSTIC 0.032 INCH GUIDE WIRE – (EXCHANGE LENGTH, EXTRA STIFF SHAFT STRENGTH)-AMPLATZ TYPE US FDA + CE/ DGCI APPROVED· Should be available in 0.032 inches size· Should be between 240-300 cm long· Should be available as straight & J-Shaped tip |
| 385 | PTFE COATED DIAGNOSTIC 0.032 INCH GUIDE WIRE – (EXCHANGE LENGTH, EXTRA STIFF SHAFT STRENGTH)-AMPLATZ TYPE US FDA + CE/ DGCI APPROVED· Should be available in 0.035 inches size· Should be between 240-300 cm long· Should be available as straight & J-Shaped tip |
| 386 | PTFE COATED DIAGNOSTIC 0.032 INCH GUIDE WIRE – (EXCHANGE LENGTH, EXTRA STIFF SHAFT STRENGTH)-AMPLATZ TYPE US FDA + CE/ DGCI APPROVED· Should be available in 0.038 inches size· Should be between 240-300 cm long· Should be available as straight & J-Shaped tip |
| 387 | HYDROPHILIC DIAGNOSTIC GUIDE WIRE – RADIFOCUS TARUMO TYPE (REGULAR LENGTH, REGULAR STIFFNESS) US FDA + CE/ DGCI APPROVED· Should be available in 0.025 inches size· Should have superelastic alloy core·Should have super flexible wire tip·Should be available in straight and angled tip·Should be between 120-300 cm long |
| 388 | HYDROPHILIC DIAGNOSTIC GUIDE WIRE – RADIFOCUS TARUMO TYPE (REGULAR LENGTH, REGULAR STIFFNESS) US FDA + CE/ DGCI APPROVED· Should be available in 0.032 inches size·Should have superelastic alloy core·Should have super flexible wire tip·Should be available in straight and angled tip·Should be between 120-300 cm long |
| 389 | HYDROPHILIC DIAGNOSTIC GUIDE WIRE – RADIFOCUS TARUMO TYPE (REGULAR LENGTH, REGULAR STIFFNESS) US FDA + CE/ DGCI APPROVED·Should be available in 0.035 inches size·Should have superelastic alloy core·Should have super flexible wire tip· Should be available in straight and angled tip· Should be between 120-300 cm long |
| 390 | HYDROPHILIC DIAGNOSTIC GUIDE WIRE – RADIFOCUS TARUMO TYPE (REGULAR LENGTH, REGULAR STIFFNESS) US FDA + CE/ DGCI APPROVED· Should be available in 0.038 inches size·Should have superelastic alloy core·Should have super flexible wire tip·Should be available in straight and angled tip·Should be between 120-300 cm long |
| 391 | RADIOFOCUS MINIPLASTIC GUIDEWIRE (, REGULAR STIFFNESS) US FDA + CE/ DGCI APPROVED•Sould be available in 0.025 inchessize• Should have superelastic alloy core•Should have super flexible wire tip•Should be available in straight and angled tip•Should be between 150-180 cm long |
| 392 | RADIOFOCUS MINIPLASTIC GUIDEWIRE (, REGULAR STIFFNESS) US FDA + CE/ DGCI APPROVED•Sould be available in 0.032, inches size• Should have superelastic alloy core•Should have super flexible wire tip• should be available in straight and angled tip• Should be between 150-180 cm long |
| 393 | RADIOFOCUS MINIPLASTIC GUIDEWIRE (, REGULAR STIFFNESS) US FDA + CE/ DGCI APPROVED•Sould be available in 0.035 inches size• Should have superelastic alloy core• Should have super flexible wire tip• Should be available in straight and angled tip•Should be between 150-180 cm long |
| 394 | RADIOFOCUS MINIPLASTIC GUIDEWIRE (, REGULAR STIFFNESS) US FDA + CE/ DGCI APPROVED•Sould be available in 0.038 inches size•Should have superelastic alloy core•Should have super flexible wire tip• Should be available in straight and angled tip•Should be between 150-180 cm long |
| 395 | RADIOFOCUS MINIPLASTIC GUIDEWIRE (LONG LENGTH) US FDA + CE/ DGCI APPROVED• Should be available in 0.025, inches size• Should have superelastic alloy core•Should have super flexible wire tip• Should be available in straight and angled tip• Should be between 260cm, 300 cm50-180 cm longUS FDA + CE/ DGCI APPROVED |
| 396 | RADIOFOCUS MINIPLASTIC GUIDEWIRE (LONG LENGTH) US FDA + CE/ DGCI APPROVED•Should be available in 0.032 Inches size• Should have superelastic alloy core•Should have super flexible wire tip• Should be available in straight and angled tip•Should be between 260cm, 300 cm50-180 cm longUS FDA + CE/ DGCI APPROVED |
| 397 | RADIOFOCUS MINIPLASTIC GUIDEWIRE (LONG LENGTH) US FDA + CE/ DGCI APPROVED•Should be available in 0.038 inches size•Should have superelastic alloy core• Should have super flexible wire tip• Should be available in straight and angled tip•Should be between 260cm, 300 cm50-180 cm longUS FDA + CE/ DGCI APPROVED |
| 398 | JUDKINS CATHETER (JR) Right judkins catheters in various standard curves and lengths. |
| 399 | JUDKINS CATHETER (JR) Right judkins catheters in various standard curves and lengths. |
| 400 | JUDKINS CATHETER (JR) Right judkins catheters in various standard curves and lengths. |
| 401 | JUDKINS CATHETER (JR) Right judkins catheters in various standard curves and lengths. |
| 402 | JUDKINS CATHETER (JR) Right judkins catheters in various standard curves and lengths. |
| 403 | JUDKINS CATHETER (JL) US FDA + CE/ DGCI APPROVED ·Left judkins catheters in various standard curves and lengths. |
| 404 | JUDKINS CATHETER (JL) US FDA + CE/ DGCI APPROVED ·Left judkins catheters in various standard curves and lengths. |
| 405 | JUDKINS CATHETER (JL) US FDA + CE/ DGCI APPROVED ·Left judkins catheters in various standard curves and lengths. |
| 406 | JUDKINS CATHETER (JL) US FDA + CE/ DGCI APPROVED ·Left judkins catheters in various standard curves and lengths. |
| 407 | JUDKINS CATHETER (JL) US FDA + CE/ DGCI APPROVED ·Left judkins catheters in various standard curves and lengths. |
| 408 | JUDKINS CATHETER PIGTAIL US FDA + CE/ DGCI APPROVED Left and Right judkins catheters in various standard curves and lengths. |
| 409 | JUDKINS CATHETER PIGTAIL US FDA + CE/ DGCI APPROVED Left and Right judkins catheters in various standard curves and lengths. |
| 410 | JUDKINS CATHETER PIGTAIL US FDA + CE/ DGCI APPROVED Left and Right judkins catheters in various standard curves and lengths. |
| 411 | JUDKINS CATHETER PIGTAIL US FDA + CE/ DGCI APPROVED Left and Right judkins catheters in various standard curves and lengths. |
| 412 | JUDKINS CATHETER PIGTAIL US FDA + CE/ DGCI APPROVED Left and Right judkins catheters in various standard curves and lengths. |
| 413 | MULTIPURPOSE CATHETER US FDA + CE/ DGCI APPROVED multipurpose catheters in various standard curves and lengths. |
| 414 | MULTIPURPOSE CATHETER US FDA + CE/ DGCI APPROVED multipurpose catheters in various standard curves and lengths. |
| 415 | MULTIPURPOSE CATHETER US FDA + CE/ DGCI APPROVED multipurpose catheters in various standard curves and lengths. |
| 416 | MULTIPURPOSE CATHETER US FDA + CE/ DGCI APPROVED multipurpose catheters in various standard curves and lengths. |
| 417 | MULTIPURPOSE CATHETER US FDA + CE/ DGCI APPROVED multipurpose catheters in various standard curves and lengths. |
| 418 | AMPLATZ CATHETER US FDA + CE/ DGCI APPROVED Amplatz left (AL) catheter in various standard curves and lengths. · |
| 419 | AMPLATZ CATHETER US FDA + CE/ DGCI APPROVED Amplatz left (AL) catheter in various standard curves and lengths. · |
| 420 | AMPLATZ CATHETER US FDA + CE/ DGCI APPROVED Amplatz left (AL) catheter in various standard curves and lengths. · |
| 421 | AMPLATZ CATHETER US FDA + CE/ DGCI APPROVED Amplatz left (AL) catheter in various standard curves and lengths. · |
| 422 | AMPLATZ CATHETER US FDA + CE/ DGCI APPROVED Amplatz left (AL) catheter in various standard curves and lengths. · |
| 423 | AMPLATZ CATHETER US FDA + CE/ DGCI APPROVED Amplatz right (AR) catheter in various standard curves and lengths. · |
| 424 | AMPLATZ CATHETER US FDA + CE/ DGCI APPROVED Amplatz right (AR) catheter in various standard curves and lengths. · |
| 425 | AMPLATZ CATHETER US FDA + CE/ DGCI APPROVED Amplatz right (AR) catheter in various standard curves and lengths. · |
| 426 | AMPLATZ CATHETER US FDA + CE/ DGCI APPROVED Amplatz right (AR) catheter in various standard curves and lengths. · |
| 427 | AMPLATZ CATHETER US FDA + CE/ DGCI APPROVED Amplatz right (AR) catheter in various standard curves and lengths. · |
| 428 | INTERNAL MAMMARY CATHETER US FDA + CE/ DGCI APPROVED · in various standard curves and lengths. |
| 429 | INTERNAL MAMMARY CATHETER US FDA + CE/ DGCI APPROVED · in various standard curves and lengths. |
| 430 | INTERNAL MAMMARY CATHETER US FDA + CE/ DGCI APPROVED · in various standard curves and lengths. |
| 431 | INTERNAL MAMMARY CATHETER US FDA + CE/ DGCI APPROVED · in various standard curves and lengths. |
| 432 | INTERNAL MAMMARY CATHETER US FDA + CE/ DGCI APPROVED · in various standard curves and lengths. |
| 433 | BY-PASS GRAFT CATHETER US FDA + CE/ DGCI APPROVED, in various standard curves and lengths. |
| 434 | BY-PASS GRAFT CATHETER US FDA + CE/ DGCI APPROVED, in various standard curves and lengths. |
| 435 | BY-PASS GRAFT CATHETER US FDA + CE/ DGCI APPROVED, in various standard curves and lengths. |
| 436 | BY-PASS GRAFT CATHETER US FDA + CE/ DGCI APPROVED, in various standard curves and lengths. |
| 437 | BY-PASS GRAFT CATHETER US FDA + CE/ DGCI APPROVED, in various standard curves and lengths. |
| 438 | TRANSRADIAL DIAGNOSTIC CORONARY CATHETER TIGER TYPE diagnostic coronary catheters of TIG curves and lengths dedicated for trans radial coronary angiography and brachial approach also US FDA + CE/ DGCI APPROVED · |
| 439 | TRANSRADIAL DIAGNOSTIC CORONARY CATHETER TIGER TYPE diagnostic coronary catheters of TIG curves and lengths dedicated for trans radial coronary angiography and brachial approach also US FDA + CE/ DGCI APPROVED · |
| 440 | TRANSRADIAL DIAGNOSTIC CORONARY CATHETER TIGER TYPE diagnostic coronary catheters of TIG curves and lengths dedicated for trans radial coronary angiography and brachial approach also US FDA + CE/ DGCI APPROVED · |
| 441 | TRANSRADIAL DIAGNOSTIC CORONARY CATHETER TIGER TYPE diagnostic coronary catheters of TIG curves and lengths dedicated for trans radial coronary angiography and brachial approach also US FDA + CE/ DGCI APPROVED · |
| 442 | TRANSRADIAL DIAGNOSTIC CORONARY CATHETER TIGER TYPE diagnostic coronary catheters of TIG curves and lengths dedicated for trans radial coronary angiography and brachial approach also US FDA + CE/ DGCI APPROVED · |
| 443 | NIH CATHETER US FDA + CE/ DGCI APPROVED ·in various standard curves and lengths. |
| 444 | NIH CATHETER US FDA + CE/ DGCI APPROVED ·in various standard curves and lengths. |
| 445 | NIH CATHETER US FDA + CE/ DGCI APPROVED ·in various standard curves and lengths. |
| 446 | NIH CATHETER US FDA + CE/ DGCI APPROVED ·in various standard curves and lengths. |
| 447 | NIH CATHETER US FDA + CE/ DGCI APPROVED ·in various standard curves and lengths. |
| 448 | COURNARD CATHETER US FDA + CE/ DGCI APPROVED ·in various standard curves and lengths. |
| 449 | COURNARD CATHETER US FDA + CE/ DGCI APPROVED ·in various standard curves and lengths. |
| 450 | COURNARD CATHETER US FDA + CE/ DGCI APPROVED ·in various standard curves and lengths. |
| 451 | COURNARD CATHETER US FDA + CE/ DGCI APPROVED ·in various standard curves and lengths. |
| 452 | COURNARD CATHETER US FDA + CE/ DGCI APPROVED ·in various standard curves and lengths. |
| 453 | INTRODUCER SHEATHS FOR PEDIATRIC USE (Size 4 Fr.) WITH J TIP/STRAIGHT INTRODUCER WIRE US FDA + CE/ DGCI APPROVED· Between 5.5-7.5 cm long· 0.021 inch straight introducer guide wire· With haemostatic valve to prevent back leak and air aspiration· With integral side port with attached 3-way stopcock· With suture eye for securing sheath· Kink resistant· With dilator-hub lock mechanism to prevent its back-out during insertion· Should have smooth and resistance free insertion |
| 454 | INTRODUCER SHEATHS FOR PEDIATRIC USE (Size 5 Fr.) WITH J TIP/STRAIGHT INTRODUCER WIRE US FDA + CE/ DGCI APPROVED· Between 5.5-7.5 cm long· 0.021 inch straight introducer guide wire· With haemostatic valve to prevent back leak and air aspiration· With integral side port with attached 3-way stopcock· With suture eye for securing sheath· Kink resistant· With dilator-hub lock mechanism to prevent its back-out during insertion· Should have smooth and resistance free insertion |
| 455 | INTRODUCER SHEATHS FOR PEDIATRIC USE (Size 6 Fr.) WITH J TIP/STRAIGHT INTRODUCER WIRE US FDA + CE/ DGCI APPROVED· Between 5.5-7.5 cm long· 0.021 inch straight introducer guide wire· With haemostatic valve to prevent back leak and air aspiration· With integral side port with attached 3-way stopcock· With suture eye for securing sheath· Kink resistant· With dilator-hub lock mechanism to prevent its back-out during insertion· Should have smooth and resistance free insertion |
| 456 | JUDKINS CATHETER (PEDIATRIC) US FDA + CE/ DGCI APPROVED·Left and Right Judkins catheters in various standard curves and lengths· Must be FDA approved |
| 457 | JUDKINS CATHETER (PEDIATRIC) US FDA + CE/ DGCI APPROVED·Left and Right Judkins catheters in various standard curves and lengths· Must be FDA approved |
| 458 | JUDKINS CATHETER (PEDIATRIC) US FDA + CE/ DGCI APPROVED·Left and Right Judkins catheters in various standard curves and lengths· Must be FDA approved |
| 459 | SPECIAL JUDKINS CORONARY CATHETER WITH 2.5 CM CURVE (PEDIATRIC) US FDA + CE/ DGCI APPROVED |
| 460 | SPECIAL JUDKINS CORONARY CATHETER WITH 2.5 CM CURVE (PEDIATRIC) US FDA + CE/ DGCI APPROVED |
| 461 | SPECIAL JUDKINS CORONARY CATHETER WITH 2.5 CM CURVE (PEDIATRIC) US FDA + CE/ DGCI APPROVED |
| 462 | ANGIOGRAPHIC DOUBLE LEUMEN TRACKING CATHETER US FDA + CE/ DGCI APPROVED |
| 463 | ANGIOGRAPHIC DOUBLE LEUMEN TRACKING CATHETER US FDA + CE/ DGCI APPROVED |
| 464 | ANGIOGRAPHIC DOUBLE LEUMEN TRACKING CATHETER US FDA + CE/ DGCI APPROVED |
| 465 | 3- ‘FRENCH’ DIAGNOSTIC CATHETERS FOR NEONATAL USE US FDA + CE/ DGCI APPROVED· Pigtail, Judkins, Multipurpose, Cobra and other diagnostic catheters of 3 Fr. size·Varying lengths and shapes |
| 466 | SWAN GANZ CATHETER US FDA + CE/ DGCI APPROVED |
| 467 | SWAN GANZ CATHETER US FDA + CE/ DGCI APPROVED |
| 468 | BALLOON TIPPED ANGIOGRAPHY CATHETER US FDA + CE/ DGCI APPROVED |
| 469 | BALLOON TIPPED ANGIOGRAPHY CATHETER US FDA + CE/ DGCI APPROVED |
| 470 | BALLOON TIPPED ANGIOGRAPHY CATHETER US FDA + CE/ DGCI APPROVED |
| 471 | BERMAN CATHETER US FDA + CE/ DGCI APPROVED· sizes· Should have 6-8 holes proximal to the balloon for dye injection· Catheter should be tapered at tip to ensure uniform diameter of the whole catheter· 10 cm marking along catheter body to confirm insertion depth |
| 472 | BERMAN CATHETER US FDA + CE/ DGCI APPROVED· Should have 6-8 holes proximal to the balloon for dye injection·Catheter should be tapered at tip to ensure uniform diameter of the whole catheter·10 cm marking along catheter body to confirm insertion depth |
| 473 | BERMAN CATHETER US FDA + CE/ DGCI APPROVED· Should have 6-8 holes proximal to the balloon for dye injection·Catheter should be tapered at tip to ensure uniform diameter of the whole catheter·10 cm marking along catheter body to confirm insertion depth |
| 474 | BERMAN CATHETER US FDA + CE/ DGCI APPROVED· Should have 6-8 holes proximal to the balloon for dye injection· Catheter should be tapered at tip to ensure uniform diameter of the whole catheter· 10 cm marking along catheter body to confirm insertion depth |
| 475 | REVERSE BERMAN CATHETER US FDA + CE/ DGCI APPROVED• Catheter should be tapered at tip to ensure uniform diameter of the whole catheter• Should have holes proximal to the balloon for dye injection• Should have a hole at the proximal tip to allow the passage over the wire |
| 476 | REVERSE BERMAN CATHETER US FDA + CE/ DGCI APPROVED• Catheter should be tapered at tip to ensure uniform diameter of the whole catheter• Should have holes proximal to the balloon for dye injection• Should have a hole at the proximal tip to allow the passage over the wire |
| 477 | REVERSE BERMAN CATHETER US FDA + CE/ DGCI APPROVED• Catheter should be tapered at tip to ensure uniform diameter of the whole catheter• Should have holes proximal to the balloon for dye injection• Should have a hole at the proximal tip to allow the passage over the wire |
| 478 | REVERSE BERMAN CATHETER US FDA + CE/ DGCI APPROVED• Catheter should be tapered at tip to ensure uniform diameter of the whole catheter• Should have holes proximal to the balloon for dye injection• Should have a hole at the proximal tip to allow the passage over the wire |
| 479 | ARTERIAL PRESSURE MONITOR LINES (100 cm long) US FDA + CE/ DGCI APPROVED• Should be soft and kink resistant• Should give reliable pressure measurements• Should have male luer lock connection at one end and a female luer lock connection at the other end• Should meet highest medical industrial standards for arterial pressure lines• Quality certification should be provided from authorized agencies. |
| 480 | ARTERIAL PRESSURE MONITOR LINES (150 cm long) US FDA + CE/ DGCI APPROVED• Should be soft and kink resistant• Should give reliable pressure measurements• Should have male luer lock connection at one end and a female luer lock connection at the other end• Should meet highest medical industrial standards for arterial pressure lines• Quality certification should be provided from authorized agencies. |
| 481 | ARTERIAL PRESSURE MONITOR LINES (200 cm long) US FDA + CE/ DGCI APPROVED• Should be soft and kink resistant• Should give reliable pressure measurements• Should have male luer lock connection at one end and a female luer lock connection at the other end• Should meet highest medical industrial standards for arterial pressure lines• Quality certification should be provided from authorized agencies. |
| 482 | STRAIGHT LONG INTRODUCER SHEATH WITH HYDROPHILIC INTRODUCER GUIDE WIRE US FDA + CE/ DGCI APPROVED· 16 cm and above long length, With 0.035 or 0.038 inch hydrophilic mini guide wire .With plastic cannula for arterial puncture |
| 483 | STRAIGHT LONG INTRODUCER SHEATH WITH HYDROPHILIC INTRODUCER GUIDE WIRE US FDA + CE/ DGCI APPROVED· 16 cm and above long length, With 0.035 or 0.038 inch hydrophilic mini guide wire .With plastic cannula for arterial puncture |
| 484 | STRAIGHT LONG INTRODUCER SHEATH WITH HYDROPHILIC INTRODUCER GUIDE WIRE US FDA + CE/ DGCI APPROVED· 16 cm and above long length,With 0.035 or 0.038 inch hydrophilic mini guide wire .With plastic cannula for arterial puncture |
| 485 | STRAIGHT LONG INTRODUCER SHEATH WITH HYDROPHILIC INTRODUCER GUIDE WIRE US FDA + CE/ DGCI APPROVED·16 cm and above long length,With 0.035 or 0.038 inch hydrophilic mini guide wire .With plastic cannula for arterial puncture |
| 486 | STRAIGHT LONG INTRODUCER SHEATH WITH HYDROPHILIC INTRODUCER GUIDE WIRE US FDA + CE/ DGCI APPROVED·16 cm and above long length, With 0.035 or 0.038 inch hydrophilic mini guide wire .With plastic cannula for arterial puncture |
| 487 | STRAIGHT LONG INTRODUCER SHEATH WITH HYDROPHILIC INTRODUCER GUIDE WIRE US FDA + CE/ DGCI APPROVED·16 cm and above long length, With 0.035 or 0.038 inch hydrophilic mini guide wire .With plastic cannula for arterial puncture |
| 488 | STRAIGHT REINFORCED SHEATH WITH HYDROPHILIC COATING US FDA + CE/ DGCI APPROVED•More than 60 cm long with side arm port• With 0.035 or 0.038 inch guide wire compatible•With Radio-opaque tip |
| 489 | STRAIGHT REINFORCED SHEATH WITH HYDROPHILIC COATING US FDA + CE/ DGCI APPROVED•More than 60 cm long with side arm port• With 0.035 or 0.038 inch guide wire compatible With Radio-opaque tip |
| 490 | STRAIGHT REINFORCED SHEATH WITH HYDROPHILIC COATING US FDA + CE/ DGCI APPROVED More than 60 cm long with side arm port• With 0.035 or 0.038 inch guide wire compatible• With Radio-opaque tip |
| 491 | STRAIGHT REINFORCED SHEATH WITH HYDROPHILIC COATING US FDA + CE/ DGCI APPROVED• More than 60 cm long with side arm port• With 0.035 or 0.038 inch guide wire compatible•With Radio-opaque tip |
| 492 | STRAIGHT REINFORCED SHEATH WITH HYDROPHILIC COATING US FDA + CE/ DGCI APPROVED• More than 60 cm long with side arm port•With 0.035 or 0.038 inch guide wire compatible•With Radio-opaque tip |
| 493 | STRAIGHT REINFORCED SHEATH WITH HYDROPHILIC COATING US FDA + CE/ DGCI APPROVED•More than 60 cm long with side arm port.With 0.035 or 0.038 inch guide wire compatible• With Radio-opaque tip |
| 494 | STRAIGHT REINFORCED SHEATH WITH HYDROPHILIC COATING US FDA + CE/ DGCI APPROVED• More than 60 cm long with side arm port•With 0.035 or 0.038 inch guide wire compatible With Radio-opaque tip |
| 495 | Long sheath for contra – lateral iliac/ femoral access US FDA + CE/ DGCI APPROVED•Should be kink resistant with a reinforcement mechanism • Should be low friction with inner coating to allow catheter manipulation• Should have distal radio-opaque tip for enhanced visibility on fluoroscopy• Should have smooth transition from dilator to seath• Should have a proximal hemostasis valve/ provision for tuohyborst valve• Should be color coded for size identification• Should be available in 4F size with the largest ID• Should have lengths ranging from 40-110 cm |
| 496 | Long sheath for contra – lateral iliac/ femoral access US FDA + CE/ DGCI APPROVED•Should be kink resistant with a reinforcement mechanism • Should be low friction with inner coating to allow catheter manipulation• Should have distal radio-opaque tip for enhanced visibility on fluoroscopy• Should have smooth transition from dilator to seath• Should have a proximal hemostasis valve/ provision for tuohyborst valve• Should be color coded for size identification• Should be available in 5F size with the largest ID• Should have lengths ranging from 40-110 cm |
| 497 | Long sheath for contra – lateral iliac/ femoral access US FDA + CE/ DGCI APPROVED• Should be kink resistant with a reinforcement mechanism • Should be low friction with inner coating to allow catheter manipulation• Should have distal radio-opaque tip for enhanced visibility on fluoroscopy• Should have smooth transition from dilator to seath• Should have a proximal hemostasis valve/ provision for tuohyborst valve• Should be color coded for size identification• Should be available in 6F size with the largest ID• Should have lengths ranging from 40-110 cm |
| 498 | Long sheath for contra – lateral iliac/ femoral access US FDA + CE/ DGCI APPROVED• Should be kink resistant with a reinforcement mechanism • Should be low friction with inner coating to allow catheter manipulation• Should have distal radio-opaque tip for enhanced visibility on fluoroscopy• Should have smooth transition from dilator to seath• Should have a proximal hemostasis valve/ provision for tuohyborst valve• Should be color coded for size identification• Should be available in 7 F size with the largest ID• Should have lengths ranging from 40-110 cm q |
| 499 | Long sheath for contra – lateral iliac/ femoral access US FDA + CE/ DGCI APPROVED•Should be kink resistant with a reinforcement mechanism • Should be low friction with inner coating to allow catheter manipulation• Should have distal radio-opaque tip for enhanced visibility on fluoroscopy• Should have smooth transition from dilator to seath• Should have a proximal hemostasis valve/ provision for tuohyborst valve• Should be color coded for size identification• Should be available in 8 F size with the largest ID• Should have lengths ranging from 40-110 cm |
| 500 | Long sheath for contra – lateral iliac/ femoral access US FDA + CE/ DGCI APPROVED•Should be kink resistant with a reinforcement mechanism•Should be low friction with inner coating to allow catheter manipulation• Should have distal radio-opaque tip for enhanced visibility on fluoroscopy•Should have smooth transition from dilator to seath•Should have a proximal hemostasis valve/ provision for tuohyborst valve•Should be color coded for size identification•Should be available in 9 F size with the largest ID• Should have lengths ranging from 40-110 cm |
| 501 | Mullin’s Sheath for special Dilation US FDA + CE/ DGCI APPROVED Should be in septal puncture needle Should be in -6F septal puncture needle |
| 502 | Angio.Kit/Ptca Kit (3 Port Many Fold With Attached Tubing One Pressure Line + Two Iv Set Connecting Tube And Two Leurlock Syringe ) US FDA / CE/ APPROVED |
| 503 | Micro Catheter for super selective catherization USFDA/CE approved |
| 504 | Micro Catheter for super selective catherization USFDA/CE approved |
| 505 | Micro catheter for super selective catherization USFDA/CE approved |
| 506 | Micro catheter for super selective catherization USFDA/CE approved |
| 507 | Multi side port catheter infusion for catheter directed thromobolysis USA/FDA/CE approved |
| 508 | Clot retrieval sheath USA/FDA/CE approved aspiration catheter 16 F including flow retriever catheter 19-25 mm,15-18mm ,11-14 mm |
| 509 | Clot retrieval sheath USA/FDA/CE approved aspiration catheter 20 F including flow retriever catheter 19-25 mm,15-18mm ,11-14 mm |
| 510 | Clot retrieval sheath USA/FDA/CE approved aspiration catheter 24 F including flow retriever catheter 19-25 mm,15-18mm ,11-14 mm |
| 511 | Loadable Microsphere for embolisation of tumour Super absobent polymer drug eluting microsphere for TACE (Trans Arterial chemo ambolization )USA/FDA/CE approved |
| 512 | Loadable Microsphere for embolisation of tumour Super absobent polymer drug eluting microsphere for TACE (Trans Arterial chemo ambolization ) USA/FDA/CE approved |
| 513 | Loadable Microsphere for embolisation of tumour Super absobent polymer drug eluting microsphere for TACE (Trans Arterial chemo ambolization ) USA/FDA/CE approved |
| 514 | PCD set puncture needle 18G,0.035,J stiff stiff wire 0.035/80 cm ,Dilator set ,Pig tail /malecot catheter 8-24F |
| 515 | Ring biliary catheter USA/FDA/CE approved catheter 8.5 F/10/3 compatible 0.038\\" length~40 cm ,catheter side ports -32 ,side port segment length 8 cm ,catheter introducer, stiffening cannula ,secured device |
| 516 | Venaseal closure system for varicose veins USA/FDA approved N butyl based adhesive formation 50/90/105/120 cm 145 cm(3/4/6/8 F ,014\\"/0.35 \\" compatible |
| 517 | Liver access and biopsy needle set USA/FDA approved USA/FDA approved 18g/60 cm biopsy needle ,14 G cannula /53.5 cm length sheath 7F |
| 518 | Tran jugular Intrahepatic Porto sytemic shunt (TIPS set ) intoducer 10F/40 cm ,toclar diameter 0.038 legth60 cm ,cannula 14 G/51.5 cm |
| 519 | Percutaneous gastrostomy balloon retention tube set catheter -12-20 F,length -10 cm ,balloon 5-20 ml |
| 520 | Biopsy guns - Should be spring loaded disposable automatic biopsy gun. Should have one handed cocking mechanism with non-roll handle design. Should have angled deep sample notch for enhanced needle action. Should have choice of two firing buttons/Dual Triger with size color coding.Should have penetration depth of 22mm. Should have sharp-beveled trocar. Should have round ergonomic handle with no-fire lock. Should have etched needle tip is grit blasted. Should be available in different Gauge size 14,16,18,20 with length size CM 10, 16,20, 25. with compatible Disposable Coaxial Needle: Should be available in all sizes compatible with Disposable core biopsy instrument/Gun. Should have color coded depth stopper that indicate the Size and match with compatible size of disposable Automatic core Biopsy gun/instrument. Should have option of blunt tip & sharp tip trocar for risk free penetration option. Should be available in Gauze Size 13,15,17,19 with different length size CM 7.8, 13.8. USFDA/CE approved |
| 521 | Biopsy guns - Should be spring loaded disposable automatic biopsy gun. Should have one handed cocking mechanism with non-roll handle design. Should have angled deep sample notch for enhanced needle action. Should have choice of two firing buttons/Dual Triger with size color coding.Should have penetration depth of 22mm. Should have sharp-beveled trocar. Should have round ergonomic handle with no-fire lock. Should have etched needle tip is grit blasted. Should be available in different Gauge size 14,16,18,20 with length size CM 10, 16,20, 25. with compatible Disposable Coaxial Needle: Should be available in all sizes compatible with Disposable core biopsy instrument/Gun. Should have color coded depth stopper that indicate the Size and match with compatible size of disposable Automatic core Biopsy gun/instrument. Should have option of blunt tip & sharp tip trocar for risk free penetration option. Should be available in Gauze Size 13,15,17,19 with different length size CM 7.8, 13.8. USFDA/CE approved |
| 522 | Biopsy guns - Should be spring loaded disposable automatic biopsy gun. Should have one handed cocking mechanism with non-roll handle design. Should have angled deep sample notch for enhanced needle action. Should have choice of two firing buttons/Dual Triger with size color coding.Should have penetration depth of 22mm. Should have sharp-beveled trocar. Should have round ergonomic handle with no-fire lock. Should have etched needle tip is grit blasted. Should be available in different Gauge size 14,16,18,20 with length size CM 10, 16,20, 25. with compatible Disposable Coaxial Needle: Should be available in all sizes compatible with Disposable core biopsy instrument/Gun. Should have color coded depth stopper that indicate the Size and match with compatible size of disposable Automatic core Biopsy gun/instrument. Should have option of blunt tip & sharp tip trocar for risk free penetration option. Should be available in Gauze Size 13,15,17,19 with different length size CM 7.8, 13.8. USFDA/CE approved |
| 523 | Biopsy guns - Should be spring loaded disposable automatic biopsy gun. Should have one handed cocking mechanism with non-roll handle design. Should have angled deep sample notch for enhanced needle action. Should have choice of two firing buttons/Dual Triger with size color coding.Should have penetration depth of 22mm. Should have sharp-beveled trocar. Should have round ergonomic handle with no-fire lock. Should have etched needle tip is grit blasted. Should be available in different Gauge size 14,16,18,20 with length size CM 10, 16,20, 25. with compatible Disposable Coaxial Needle: Should be available in all sizes compatible with Disposable core biopsy instrument/Gun. Should have color coded depth stopper that indicate the Size and match with compatible size of disposable Automatic core Biopsy gun/instrument. Should have option of blunt tip & sharp tip trocar for risk free penetration option. Should be available in Gauze Size 13,15,17,19 with different length size CM 7.8, 13.8. USFDA/CE approved |
| 524 | Biopsy guns - Should be spring loaded disposable automatic biopsy gun. Should have one handed cocking mechanism with non-roll handle design. Should have angled deep sample notch for enhanced needle action. Should have choice of two firing buttons/Dual Triger with size color coding.Should have penetration depth of 22mm. Should have sharp-beveled trocar. Should have round ergonomic handle with no-fire lock. Should have etched needle tip is grit blasted. Should be available in different Gauge size 14,16,18,20 with length size CM 10, 16,20, 25. with compatible Disposable Coaxial Needle: Should be available in all sizes compatible with Disposable core biopsy instrument/Gun. Should have color coded depth stopper that indicate the Size and match with compatible size of disposable Automatic core Biopsy gun/instrument. Should have option of blunt tip & sharp tip trocar for risk free penetration option. Should be available in Gauze Size 13,15,17,19 with different length size CM 7.8, 13.8. USFDA/CE approved |
| 525 | Biopsy guns - Should be spring loaded disposable automatic biopsy gun. Should have one handed cocking mechanism with non-roll handle design. Should have angled deep sample notch for enhanced needle action. Should have choice of two firing buttons/Dual Triger with size color coding.Should have penetration depth of 22mm. Should have sharp-beveled trocar. Should have round ergonomic handle with no-fire lock. Should have etched needle tip is grit blasted. Should be available in different Gauge size 14,16,18,20 with length size CM 10, 16,20, 25. with compatible Disposable Coaxial Needle: Should be available in all sizes compatible with Disposable core biopsy instrument/Gun. Should have color coded depth stopper that indicate the Size and match with compatible size of disposable Automatic core Biopsy gun/instrument. Should have option of blunt tip & sharp tip trocar for risk free penetration option. Should be available in Gauze Size 13,15,17,19 with different length size CM 7.8, 13.8. USFDA/CE approved |
| 526 | Biopsy guns - Should be spring loaded disposable automatic biopsy gun. Should have one handed cocking mechanism with non-roll handle design. Should have angled deep sample notch for enhanced needle action. Should have choice of two firing buttons/Dual Triger with size color coding.Should have penetration depth of 22mm. Should have sharp-beveled trocar. Should have round ergonomic handle with no-fire lock. Should have etched needle tip is grit blasted. Should be available in different Gauge size 14,16,18,20 with length size CM 10, 16,20, 25. with compatible Disposable Coaxial Needle: Should be available in all sizes compatible with Disposable core biopsy instrument/Gun. Should have color coded depth stopper that indicate the Size and match with compatible size of disposable Automatic core Biopsy gun/instrument. Should have option of blunt tip & sharp tip trocar for risk free penetration option. Should be available in Gauze Size 13,15,17,19 with different length size CM 7.8, 13.8. USFDA/CE approved |
| 527 | Biopsy guns - Should be spring loaded disposable automatic biopsy gun. Should have one handed cocking mechanism with non-roll handle design. Should have angled deep sample notch for enhanced needle action. Should have choice of two firing buttons/Dual Triger with size color coding.Should have penetration depth of 22mm. Should have sharp-beveled trocar. Should have round ergonomic handle with no-fire lock. Should have etched needle tip is grit blasted. Should be available in different Gauge size 14,16,18,20 with length size CM 10, 16,20, 25. with compatible Disposable Coaxial Needle: Should be available in all sizes compatible with Disposable core biopsy instrument/Gun. Should have color coded depth stopper that indicate the Size and match with compatible size of disposable Automatic core Biopsy gun/instrument. Should have option of blunt tip & sharp tip trocar for risk free penetration option. Should be available in Gauze Size 13,15,17,19 with different length size CM 7.8, 13.8. USFDA/CE approved |
| 528 | Biopsy guns - Should be spring loaded disposable automatic biopsy gun. Should have one handed cocking mechanism with non-roll handle design. Should have angled deep sample notch for enhanced needle action. Should have choice of two firing buttons/Dual Triger with size color coding.Should have penetration depth of 22mm. Should have sharp-beveled trocar. Should have round ergonomic handle with no-fire lock. Should have etched needle tip is grit blasted. Should be available in different Gauge size 14,16,18,20 with length size CM 10, 16,20, 25. with compatible Disposable Coaxial Needle: Should be available in all sizes compatible with Disposable core biopsy instrument/Gun. Should have color coded depth stopper that indicate the Size and match with compatible size of disposable Automatic core Biopsy gun/instrument. Should have option of blunt tip & sharp tip trocar for risk free penetration option. Should be available in Gauze Size 13,15,17,19 with different length size CM 7.8, 13.8. USFDA/CE approved |
| 529 | Biopsy guns - Should be spring loaded disposable automatic biopsy gun. Should have one handed cocking mechanism with non-roll handle design. Should have angled deep sample notch for enhanced needle action. Should have choice of two firing buttons/Dual Triger with size color coding.Should have penetration depth of 22mm. Should have sharp-beveled trocar. Should have round ergonomic handle with no-fire lock. Should have etched needle tip is grit blasted. Should be available in different Gauge size 14,16,18,20 with length size CM 10, 16,20, 25. with compatible Disposable Coaxial Needle: Should be available in all sizes compatible with Disposable core biopsy instrument/Gun. Should have color coded depth stopper that indicate the Size and match with compatible size of disposable Automatic core Biopsy gun/instrument. Should have option of blunt tip & sharp tip trocar for risk free penetration option. Should be available in Gauze Size 13,15,17,19 with different length size CM 7.8, 13.8. USFDA/CE approved |
| 530 | Breast Nodule LocalizationWire Should have curved locking element that provide superior migration resistance. The Localization wire can be repositioned or removed after placement if required. USFDA/CE approved |
| 531 | Disposable Semi-Automatic Core Biopsy Instrument with Compatible Coaxial Needle.Should be available with dual penetration throw of 10 and 20mm in single instrument. Should be available with fire ready indicator. Should be available with compatible coaxial needle set with a blunt tip needle & trocar Needle. Should be USFDA approved. |
| 532 | Ultra clip Disposable Breast tissue marker should be available in Coil Shape & Ribbon Shape. Should have color coded dual triggers identify different marker shape. Should be visible in Ultrasound, MRI, Mammography imaging. Should be Available in Needle size of 17 Gauge. Should be available in Coil Shape and ribbon shape. |
| 533 | Bone Marrow Biopsy Needle with diamond Bevel tip & tapered distal canula. Disposable bone marrow biopsy needle should have Ergonomic T- handle design with seprate handle cap. Should have Trocar/diamond tip for easy coring of bone. Should have triple crown cannula tip with 6 facets.should be available with narrow acquition cardle with sample size verification marking should be available in 8,11,13 Gauze USFDA/CE approved |
| 534 | Bone Marrow Biopsy Needle with diamond Bevel tip & tapered distal canula. Disposable bone marrow biopsy needle should have Ergonomic T- handle design with seprate handle cap. Should have Trocar/diamond tip for easy coring of bone. Should have triple crown cannula tip with 6 facets.should be available with narrow acquition cardle with sample size verfication marking should be available in 8,11,13 Gauze USFDA/CE approved |
| 535 | Bone Marrow Biopsy Needle with diamond Bevel tip & tapered distal canula. Disposable bone marrow biopsy needle should have Ergonomic T- handle design with seprate handle cap. Should have Trocar/diamond tip for easy coring of bone. Should have triple crown cannula tip with 6 facets.should be available with narrow acquition cardle with sample size verfication marking should be available in 8,11,13 Gauze USFDA/CE approved |
| 536 | Silicone foley's catheter with three noble metal alloy coating consisting of gold, silver & Palladium (coated internally & externally surfaces) |
| 537 | Silicone foley's catheter with three noble metal alloy coating consisting of gold, silver & Palladium (coated internally & externally surfaces) |
| 538 | Silicone foley's catheter with three noble metal alloy coating consisting of gold, silver & Palladium (coated internally & externally surfaces) |
| 539 | Silicone foley's catheter with three noble metal alloy coating consisting of gold, silver & Palladium (coated internally & externally surfaces) |
| 540 | Silicone foley's catheter with three noble metal alloy coating consisting of gold, silver & Palladium (coated internally & externally surfaces) |
| 541 | Silicone foley's catheter with three noble metal alloy coating consisting of gold, silver & Palladium (coated internally & externally surfaces) |
| 542 | Silicone foley's catheter with three noble metal alloy coating consisting of gold, silver & Palladium (coated internally & externally surfaces) |
| 543 | Cutting & Coagulations device with Tissue fusion ligasure technology having Maryland jaw sealer and divider with Wide Jaw Aperture 13mm and Cut Length 18.5mm with Shaft Rotation of 350 degrees and with One Step Sealing Mechanism. Should have the manual cutting mechanism.And it should have Including 7mm Cutting and coag with USFDA . |
| 544 | Cutting &Coagulations device with Tissue fusion ligature technology have Small jaw tissue sealing system for open procedures Vessel sealing instrument with Cut Length of 14.7 mm, Seal Length of 16.5mm, Jaw Angle 28 degrees. Should have the manual cutting mechanism.And its should have Including 7mm Cutting and coag with USFDA . |
| 545 | Cutting &Coagulations device with Tissue fusion ligature technology Laparoscopic blunt tipped vessel sealer and divider 37 cm long 5mm instrument. Wide Jaw Aperture 14.5 mm with Shaft rotation of 180 degrees ; multifunctional laparoscopic device for tissue fusion.And its should have Including 7mm Cutting and coag with USFDA . |
| 546 | Cutting &Coagulations device with Tissue fusion ligasure technology instrument for open surgeries with instrument length between 18-19cm and electrode length between 16-17cm, having 28 degree curved jaw with contoured tip for blunt dissection and having activation both through hand activation and foot activation with a manually controlled cutting mechanism. |
| 547 | Cutting &Coagulations device with Tissue fusion ligasuretechnology have36mm jaw length, 180 degree rotatable instrument with curved blade for large volume tissue. Should have the manual cutting mechanism. |
| 548 | Cutting &Coagulations device with Tissue fusion ligasuretechnology have Vessel sealing instrument for open surgeries with reusable clamp length between 16-18cm, with 12-14 degree jaw curve.And its should have Including 7mm Cutting and coag with USFDA . |
| 549 | Double lumen catheter with kit internal juglar / straight( catheter should be madeup of flexible radiopaque polyurethane with a radiopaque tip, easy visualization in X-ray. Accessory should be provided like catheter ,dialator ,introducer, needle 18 G, guidewire with dispencer and injection caps. catheter should be D to have consistent blood flow with laser cut side slot |
| 550 | Double lumen catheter with kit internal juglar / straight (catheter should be madeup of flexible radiopaque polyurethane with a radiopaque tip, easy visualization in X-ray. Accessory should be provided like catheter ,dialator ,introducer, needle 18 G, guidewire with dispencer and injection caps. catheter should be D to have consistent blood flow with laser cut side slot |
| 551 | Double lumen catheter with kit internal juglar / straight (catheter should be madeup of flexible radiopaque polyurethane with a radiopaque tip, easy visualization in X-ray. Accessory should be provided like catheter ,dialator ,introducer, needle 18 G, guidewire with dispencer and injection caps. catheter should be D to have consistent blood flow with laser cut side slot |
| 552 | Double lumen catheter with kit internal juglar / straight(catheter should be madeup of flexible radiopaque polyurethane with a radiopaque tip, easy visualization in X-ray. Accessory should be provided like catheter ,dialator ,introducer, needle 18 G, guidewire with dispencer and injection caps. catheter should be D to have consistent blood flow with laser cut side slot |
| 553 | Double lumen catheter with kit internal juglar / straight (catheter should be madeup of flexible radiopaque polyurethane with a radiopaque tip, easy visualization in X-ray. Accessory should be provided like catheter ,dialator ,introducer, needle 18 G, guidewire with dispencer and injection caps. catheter should be D to have consistent blood flow with laser cut side slot |
| 554 | Double lumen catheter with kit internal juglar / straight (catheter should be madeup of flexible radiopaque polyurethane with a radiopaque tip, easy visualization in X-ray. Accessory should be provided like catheter ,dialator ,introducer, needle 18 G, guidewire with dispencer and injection caps. catheter should be D to have consistent blood flow with laser cut side slot |
| 555 | Long term double lumen dialysis catheter with kit accessories should be provided ( catheter,pull apart sheath, dialator, tunneling stylet,guide wire j/s,with disppencer and injection Caps, symmetrical tip retrograde and antigrade |
| 556 | Long term double lumen dialysis catheter with kit accessories should be provided ( catheter,pull apart sheath, dialator, tunneling stylet,guide wire j/s,with disppencer and injection Caps, symmetrical tip retrograde and antigrade |
| 557 | Long term double lumen dialysis catheter with kit accessories should be provided ( catheter,pull apart sheath, dialator, tunneling stylet,guide wire j/s,with disppencer and injection Caps, symmetrical tip retrograde and antigrade |
| 558 | Long term double lumen dialysis catheter with kit accessories should be provided ( catheter,pull apart sheath, dialator, tunneling stylet,guide wire j/s,with disppencer and injection Caps, symmetrical tip retrograde and antigrade |
| 559 | Transperant surgical wound dressing wuth a dimensional hydrocellularpad microbicidle proteciton and anti microbial property |
| 560 | Transperant surgical wound dressing wuth a dimensional hydrocellularpad microbicidle proteciton and anti microbial property |
| 561 | Transperant surgical wound dressing wuth a dimensional hydrocellularpad microbicidle proteciton and anti microbial property |
| 562 | Transperant surgical wound dressing wuth a dimensional hydrocellularpad microbicidle proteciton and anti microbial property |
| 563 | Transperant surgical wound dressing wuth a dimensional hydrocellularpad microbicidle proteciton and anti microbial property |
| 564 | Non-Fibre Optic Single Use Adult Scope Channel width :2.2 mmInsertion tube diameter :5.0mm.working length :600 mmBending range :180 degree up & 180 degree downField of view :85 degree or moreDirection of View : 0 degree (Forward view)Depth of Field :8-50 mm or betterMinimum ETT inner dia :6 mmIllumination Method :LEDComplete system should be US-FDA and European CE certified |
| 565 | MULTI-VENT MASK Pediatric, MULTI-VENT MASK Pediatric, AIR ENTRAINMENT MASKS, must be Safe, simple delivery of variable oxygen concentrations. Each mask to includes color-coded diluters: green for low concentration, white for medium concentration. Locking ring to secure flow setting. Must Include adaptor for high humidity entrainment. Complete kit with 7-ft oxygen tubing. Manufacturer must be US-FDA registered & certified with EN/EU ISO 13485 & applicable 510K & CE certification. |
| 566 | Incentive Spirometer Incentive Spirometer with wide flow range between 200 cc/sec and 1200 cc/sec. Must have Dual-chamber design to help create constant resistance that lifts ball when patient maintains inspiration equal to selected Adjustable flow setting & clearly marked flow settings for easy monitoring. Manufacturer must be US-FDA registered & certified with EN/EU ISO 13485 & applicable 510K & CE certification |
| 567 | Closed Suction Catheter MDI Port Has Isolated turbo cleaning chamber for cleaning catheter tip with MDI Port.Catheter is made up of medical grade Silicon Material,Catheter has Zig-Zag Ports for better suctioning. Twin PEEP seals. Available in Both Endotracheal and Tracheostomy Version. Can be used for 72hr. |
| 568 | Closed Suction Catheter MDI Port Has Isolated turbo cleaning chamber for cleaning catheter tip with MDI Port.Catheter is made up of medical grade Silicon Material,Catheter has Zig-Zag Ports for better suctioning. Twin PEEP seals. Available in Both Endotracheal and Tracheostomy Version. Can be used for 72hr. |
| 569 | Closed Suction Catheter Has Isolated turbo cleaning chamber for cleaning catheter tip.Catheter is made up of medical grade Silicon Material,Catheter has Zig-Zag Ports for better suctioning. Twin PEEP seals. Available in Both Endotracheal and Tracheostomy Version.Can be used for 72hr. |
| 570 | Closed Suction Catheter Has Isolated turbo cleaning chamber for cleaning catheter tip.Catheter is made up of medical grade Silicon Material,Catheter has Zig-Zag Ports for better suctioning. Twin PEEP seals. Available in Both Endotracheal and Tracheostomy Version.Can be used for 72hr. |
| 571 | Fenestrated Tracheostomy tube cuffed with 2 inner cannula, inner cannula should reduce the ID by 1mm of tracheostomy tube one inner cannula is with Five fenestration holes and one is without fenestration |
| 572 | Multifocal IOL Biconvex, single piece designOptic size 6 mm, Overall 12-13 mm sizeTwo haptics, modified CUV blocking capability360 degrees square edge, sterile packingFoldable lens with insertion via injector, should able to insert in sub 2.8 m.mSterile disposable injector with cartridge along with each IOLInjector should be of good quality with smooth injection without damaging IOLDiopters required +16 to +25 DDiffractive multifocal design with +3 to +4 Dioptre additionShould be ISO or CE certifiedManufacturer should be asked to supply samples for approval3 piece feldable 11-28 D |
| 573 | Glaucoma Drainage Implant (VALVED) with silicon tube adult |
| 574 | Glaucoma Drainage Implant (VALVED) with silicon tube paediatric |
| 575 | Eye Sphere Implants Implantable grade PMMA sphere for enclueation and evisceration procedure (PMMA) Size / Sphere diameter - |
| 576 | Eye Sphere Implants Implantable grade PMMA sphere for enclueation and evisceration procedure (PMMA) Size / Sphere diameter - |
| 577 | Eye Sphere Implants Implantable grade PMMA sphere for enclueation and evisceration procedure (PMMA) Size / Sphere diameter - |
| 578 | Eye Sphere Implants Implantable grade PMMA sphere for enclueation and evisceration procedure (PMMA) Size / Sphere diameter - |
| 579 | Eye Sphere Implants Implantable grade PMMA sphere for enclueation and evisceration procedure (PMMA) Size / Sphere diameter - |
| 580 | Eye Sphere Implants Implantable grade silicone sphere for enclueation and evisceration procedure (Silicone) Size / Sphere diameter - |
| 581 | Eye Sphere Implants Implantable grade silicone sphere for enclueation and evisceration procedure (Silicone) Size / Sphere diameter - |
| 582 | Eye Sphere Implants Implantable grade silicone sphere for enclueation and evisceration procedure (Silicone) Size / Sphere diameter - |
| 583 | Eye Sphere Implants Implantable grade silicone sphere for enclueation and evisceration procedure (Silicone) Size / Sphere diameter - |
| 584 | Eye Sphere Implants Implantable grade silicone sphere for enclueation and evisceration procedure (Silicone) Size / Sphere diameter - |
| 585 | Monocanalicular self retaining silicone stent for canalicular repair - Medical graded silicone implant for reconstructing traumatic canalicular lacerations. Silicone rod length40MM, Silicone rod diameter 0.64 MM |
| 586 | Lacrimal Intubation set for DCR surgery – Bicanalicular lacrimal intubation set comprised of two flexible stainless steel probes attached through a hollow medical tube which is used in conventional DCR procedure. Probe length Probe diameter Silicon tube length Silicon tube ID Silicon tube OD - 11 cm 0.60 mm (23G) 30 cm 0.30 mm 0.64 mm |
| 587 | Scleral fixiated intraoccular lense having multifoccal toric ,three piece foldable intraoccular lense |
| 588 | Vibratory PEP therapy device for Pead . Patients , deliver airflow vibrations to the patients from 5-30 Hz Expiratory resistance / Frequency dial to allow therapy to be adjusted to patients's needs |
| 589 | Tracheostomy tube cuffed with Sub-glotic suction line and with 2 inner cannula kit, inner cannula should reduce the ID by 1mm of tracheostomy tube |
| 590 | Dry lithium Heparin pre filled ABG Syringe With Air Removal Filter cap 1ml |
| 591 | Dry lithium Heparin pre filled ABG Syringe With Air Removal Filter cap 3ml |
| 592 | Central Line Triple lumen with Y needle and Nitinol guide wire 8.5 fr with 16cm / 20cm catheter with Tecoflex material |
| 593 | Central Line Quadra lumen with Y needle and Nitinol guide wire 8.5 fr with 15cm / 20cm catheter with tecoflex material |
| 594 | Central Line Quadra lumen with straight needle and Nitinol guide wire 8.5 fr with 15cm / 20cm catheter with tecoflex material |
| 595 | Peripherally inserted central line for high flow/ power injectionSterile made of polyurethane Single 55 cm long, 5 french single, Double and Triple Lumen made of polyutherane with guide wire & microintroducer. Should deliever infusion at 5 ml/sec rate and have reverse taper hub to provide kink resitance. Introducer needle of 21 G. and used for power injection & monitoring CVP . |
| 596 | Latex folley balloon Catheter |
| 597 | Latex folley balloon Catheter |
| 598 | RYLE’S TUBE |
| 599 | RYLE’S TUBE |
| 600 | Post Operative Surgical Cover Dressings Hydrofiber Dressings with 1.2% w/w Impregnated Ionic Silver & Tripple Hydrocolloid Matrix Dressings with Broad Spectrum Bactricidal Efficacy with Gel forming Technology, CE, ISO & FDA Approved |
| 601 | Post Operative Surgical Cover Dressings Hydrofiber Dressings with 1.2% w/w Impregnated Ionic Silver & Tripple Hydrocolloid Matrix Dressings with Broad Spectrum Bactricidal Efficacy with Gel forming Technology, CE, ISO & FDA Approved |
| 602 | Post Operative Surgical Cover Dressings Hydrofiber Dressings with 1.2% w/w Impregnated Ionic Silver & Tripple Hydrocolloid Matrix Dressings with Broad Spectrum Bactricidal Efficacy with Gel forming Technology, CE, ISO & FDA Approved |
| 603 | 2 PCS FLAT BASE OSTOMY BODY FIT 60 MM Kit 2-piece system base plate with body fit additional elastic adhesive technology (Elastic modulus-0.18 N/mm), With 4 ears belt lock. Colostomy Bag, consists one barrier foil and a Oecotex certified water repellent Textile neutral grey colour material. Triple layer filter with full circle pre filter and three times fold Velcro locking drainage. Audible Click sound locking system with highlighted colour lock button. coupling with wave-shaped locking bag. Window on bag for inspection 60MM, Elastic Tape in semi-circular shape with hydrocolloid adhesive for extra security of base plate. Adhesive remover spray consists of hexamethyldisiloxane and cyclonentasiloxane silicone polymers for easy removal of the base plate, alcohol free, sting free 50 mL. Cream to Maintain Peristomal PH value (5.5) of skin contain magnesium citrate, Glycerine, petrolatum, Citric acid to moisturize and prevent damage to skin 60 mL. Non Alcoholic Ostomy Paste for Filling and Sealing the peristomal skin around the stoma Contains polyaliphatic Hydrocarbon , Water base , Gaur Gum 60 gm. Ostomy Powder with natural ingredients such as CMC, Guar Gum and Xanthan Gum for peristomal skin excoriation 25 gm. Cleanser to clean skin exposed to intestinal secretions consist of Isopropyl alcohol, allantoin, natural coconut oil . Lubricating deodorant to neutralize odour and provide lubricating effect to ensure content at the bottom not around stoma for easier to empty bag 250 mL. Skin Barrier for healthy peristomal skin or risk of skin damage due to bady secretions or skin damage already developed consist of Polyethylene, plasticizer, Polyamide, artificial Resin, CMC, SIS ( 20CMx20CM), Neutral grey colour standerd size belt Compatible for bags having 4 ear hooks |
| 604 | 2 PCS FLAT BASE OSTOMY BODY FIT 70 MM Kit 2-piece system base plate with body fit additional elastic adhesive technology (Elastic modulus-0.18 N/mm), With 4 ears belt lock. Colostomy Bag, consists one barrier foil and a Oecotex certified water repellent Textile neutral grey colour material. Triple layer filter with full circle pre filter and three times fold Velcro locking drainage. Audible Click sound locking system with highlighted colour lock button. coupling with wave-shaped locking bag. one side transparent for inspection. 70MM. Adhesive remover spray consists of hexamethyldisiloxane and cyclonentasiloxane silicone polymers for easy removal of the base plate, alcohol free, sting free 50 mL. Cream to Maintain Peristomal PH value (5.5) of skin contain magnesium citrate, Glycerine, petrolatum, Citric acid to moisturize and prevent damage to skin 60 mL. Non Alcoholic Ostomy Paste for Filling and Sealing the peristomal skin around the stoma Contains polyaliphatic Hydrocarbon , Water base , Gaur Gum 60 gm. Ostomy Powder with natural ingredients such as CMC, Guar Gum and Xanthan Gum for peristomal skin excoriation 25 gm. Cleanser to clean skin exposed to intestinal secretions consist of Isopropyl alcohol, allantoin, natural coconut oil . Lubricating deodorant to neutralize odour and provide lubricating effect to ensure content at the bottom not around stoma for easier to empty bag 250 mL. Skin Barrier for healthy peristomal skin or risk of skin damage due to bady secretions or skin damage already developed consist of Polyethylene, plasticizer, Polyamide, artificial Resin, CMC, SIS ( 20CMx20CM), Neutral grey colour standerd size belt Compatible for bags having 4 ear hooks |
| 605 | 2 PCS CONVEX BASE OSTOMY BODY FIT 60 MM Kit Two-piece system 6 mm aperture convex with integrated flex line base plate. body fit additional elastic adhesive technology (Elastic modulus-0.18 N/mm), With 4 ears belt lock.Colostomy Bag, consists one barrier foil and a Oecotex certified water repellent Textile neutral grey colour material. Triple layer filter with full circle pre filter and three times fold Velcro locking drainage. Audible Click sound locking system with highlighted colour lock button. coupling with wave-shaped locking bag. Window on bag for inspection 60MM. Adhesive remover spray consists of hexamethyldisiloxane and cyclonentasiloxane silicone polymers for easy removal of the base plate, alcohol free, sting free 50 mL. Cream to Maintain Peristomal PH value (5.5) of skin contain magnesium citrate, Glycerine, petrolatum, Citric acid to moisturize and prevent damage to skin 60 mL. Non Alcoholic Ostomy Paste for Filling and Sealing the peristomal skin around the stoma Contains polyaliphatic Hydrocarbon , Water base , Gaur Gum 60 gm. Ostomy Powder with natural ingredients such as CMC, Guar Gum and Xanthan Gum for peristomal skin excoriation 25 gm. Cleanser to clean skin exposed to intestinal secretions consist of Isopropyl alcohol, allantoin, natural coconut oil . Lubricating deodorant to neutralize odour and provide lubricating effect to ensure content at the bottom not around stoma for easier to empty bag 250 mL. Skin Barrier for healthy peristomal skin or risk of skin damage due to bady secretions or skin damage already developed consist of Polyethylene, plasticizer, Polyamide, artificial Resin, CMC, SIS ( 20CM x 20 CM)Neutral grey colour standerd size belt Compatible for bags having 4 ear hooks |
| 606 | 2 PCS CONVEX BASE OSTOMY BODY FIT 70 MM Kit Two-piece system 6 mm aperture convex with integrated flex line base plate. body fit additional elastic adhesive technology (Elastic modulus-0.18 N/mm), With 4 ears belt lock.Colostomy Bag, consists one barrier foil and a Oecotex certified water repellent Textile neutral grey colour material. Triple layer filter with full circle pre filter and three times fold Velcro locking drainage. Audible Click sound locking system with highlighted colour lock button. coupling with wave-shaped locking bag. Window on bag for inspection 70MM. Adhesive remover spray consists of hexamethyldisiloxane and cyclonentasiloxane silicone polymers for easy removal of the base plate, alcohol free, sting free 50 mL. Cream to Maintain Peristomal PH value (5.5) of skin contain magnesium citrate, Glycerine, petrolatum, Citric acid to moisturize and prevent damage to skin 60 mL. Non Alcoholic Ostomy Paste for Filling and Sealing the peristomal skin around the stoma Contains polyaliphatic Hydrocarbon , Water base , Gaur Gum 60 gm. Ostomy Powder with natural ingredients such as CMC, Guar Gum and Xanthan Gum for peristomal skin excoriation 25 gm. Cleanser to clean skin exposed to intestinal secretions consist of Isopropyl alcohol, allantoin, natural coconut oil . Lubricating deodorant to neutralize odour and provide lubricating effect to ensure content at the bottom not around stoma for easier to empty bag 250 mL. Skin Barrier for healthy peristomal skin or risk of skin damage due to bady secretions or skin damage already developed consist of Polyethylene, plasticizer, Polyamide, artificial Resin, CMC, SIS ( 20CM x 20 CM), Neutral grey colour standerd size belt Compatible for bags having 4 ear hooks |
| 607 | 1 PCS TRASNPARENT COLOSTOMY BODY FIT 60MM Kit One-piece colostomy Bag- body fit additional elastic adhesive technology (Elastic modulus-0.34 N/mm), Bag consists one barrier foil and a Oecotex certified water repellent Textile neutral grey colour material. Triple layer filter with full circle pre filter and three times fold Velcro locking drainage. one side transparent for inspection 60mm. Adhesive remover spray consists of hexamethyldisiloxane and cyclonentasiloxane silicone polymers for easy removal of the base plate, alcohol free, sting free 50 mL. Cream to Maintain Peristomal PH value (5.5) of skin contain magnesium citrate, Glycerine, petrolatum, Citric acid to moisturize and prevent damage to skin 60 mL. Non Alcoholic Ostomy Paste for Filling and Sealing the peristomal skin around the stoma Contains polyaliphatic Hydrocarbon , Water base , Gaur Gum 60 gm. Ostomy Powder with natural ingredients such as CMC, Guar Gum and Xanthan Gum for peristomal skin excoriation 25 gm. Cleanser to clean skin exposed to intestinal secretions consist of Isopropyl alcohol, allantoin, natural coconut oil . Lubricating deodorant to neutralize odour and provide lubricating effect to ensure content at the bottom not around stoma for easier to empty bag 250 mL. Skin Barrier for healthy peristomal skin or risk of skin damage due to bady secretions or skin damage already developed consist of Polyethylene, plasticizer, Polyamide, artificial Resin, CMC, SIS ( 20CM x 20 CM) |
| 608 | 2 PCS FLAT BASE OSTOMY BODY FIT BAG 60 MM 2-piece system base plate with body fit additional elastic adhesive technology (Elastic modulus-0.18 N/mm), With 4 ears belt lock. Colostomy Bag, consists one barrier foil and a Oecotex certified water repellent Textile neutral grey colour material. Triple layer filter with full circle pre filter and three times fold Velcro locking drainage. Audible Click sound locking system with highlighted colour lock button. coupling with wave-shaped locking bag. Window on bag for inspection 60MM |
| 609 | 2 PCS FLAT BASE OSTOMY BODY FIT BAG 70 MM 2-piece system base plate with body fit additional elastic adhesive technology (Elastic modulus-0.18 N/mm), With 4 ears belt lock. Colostomy Bag, consists one barrier foil and a Oecotex certified water repellent Textile neutral grey colour material. Triple layer filter with full circle pre filter and three times fold Velcro locking drainage. Audible Click sound locking system with highlighted colour lock button. coupling with wave-shaped locking bag. one side transparent for inspection. 70MM. |
| 610 | 2 PCS CONVEX BASE OSTOMY BODY FIT BAG 60 MM Two-piece system 6 mm aperture convex with integrated flex line base plate. body fit additional elastic adhesive technology (Elastic modulus-0.18 N/mm), With 4 ears belt lock.Colostomy Bag, consists one barrier foil and a Oecotex certified water repellent Textile neutral grey colour material. Triple layer filter with full circle pre filter and three times fold Velcro locking drainage. Audible Click sound locking system with highlighted colour lock button. coupling with wave-shaped locking bag. Window on bag for inspection 60MM. |
| 611 | 2 PCS CONVEX BASE OSTOMY BODY FIT BAG 70 MM Two-piece system 6 mm aperture convex with integrated flex line base plate. body fit additional elastic adhesive technology (Elastic modulus-0.18 N/mm), With 4 ears belt lock.Colostomy Bag, consists one barrier foil and a Oecotex certified water repellent Textile neutral grey colour material. Triple layer filter with full circle pre filter and three times fold Velcro locking drainage. Audible Click sound locking system with highlighted colour lock button. coupling with wave-shaped locking bag. Window on bag for inspection 70MM. |
| 612 | 1 PCS TRASNPARENT COLOSTOMY BODY FIT BAG 60MM One-piece colostomy Bag- body fit additional elastic adhesive technology (Elastic modulus-0.34 N/mm), Bag consists one barrier foil and a Oecotex certified water repellent Textile neutral grey colour material. Triple layer filter with full circle pre filter and three times fold Velcro locking drainage. one side transparent for inspection 60mm. |
| 613 | Non-Fibre Optic Single Use Large Scope Channel width :2.8mm Insertion tube diameter :5.8 mm.working length :600 mmBending range :180 degree up & 160 degree downField of view :85 degree or moreDirection of View :0 degree (Forward view)Depth of Field :8 -50 mm or betterMinimum ETT inner Dia :7 mmIllumination Method :LEDComplete system should be US-FDA and European CE certified. |
| 614 | Antimicrobial Silver dresssing Sterile non-occulusive wound contact layer consists of silver healing Matrix made of polyester mesh impregnated with hydrocolloid particles( CMC) ,petroleum jelly, polymers and silver salts with demonstrated in vitro antibacterial activity upto 7 days, using patented Lipido- colloid technology (TLC) |
| 615 | Antimicrobial Silver dresssing Sterile non-occulusive wound contact layer consists of silver healing Matrix made of polyester mesh impregnated with hydrocolloid particles( CMC) ,petroleum jelly, polymers and silver salts with demonstrated in vitro antibacterial activity upto 7 days, using patented Lipido- colloid technology (TLC) |
| 616 | Non-Fibre Optic Single Use Cysto Scope for DJR & Diagnostic Cystoscope It should be capable of easy navigation and fast identification of anatomical landmarks The scopes should be sterile packed One CMOS camera and two LED light source should be integrated at the distal end Minimum length of the scope should be 380 - 400mm Working channel should be of 6.5 - 6.6 FRThe Control Lever on handle for the movement of distal tip up & Down in a single plane with 210 degree up and 120 degree down |
| 617 | Non-Fibre Optic Single Use Paediatrics Scope Channel width :1.2mm Insertion tube diameter :3.8 mm.Working length :600 mmBending range :180 degree up & 180 degree downField of view :85 degree or moreDirection of View :0 degree (Forward view)Depth of Field :8 -50 mm or betterMinimum ETT inner Dia :5 mmIllumination Method :LEDComplete system should be US-FDA and European CE certified. |
| 618 | Sterile Self adherent with Lipido colloid technology sterile self -adherent patented TLC matrix (lipido colloid technology) wound contact layer combined with absorbent polyurethane foam pad , a superabsorbent layer ,a vapour permeable waterproof outer film with soft silicone adhesive border on the edges for atraumatic removal and repositioning of dressing. |
| 619 | Sterile Self adherent with Lipido colloid technology sterile self -adherent patented TLC matrix (lipido colloid technology) wound contact layer combined with absorbent polyurethane foam pad , a superabsorbent layer ,a vapour permeable waterproof outer film with soft silicone adhesive border on the edges for atraumatic removal and repositioning of dressing. |
| 620 | Sterile Self adherent with Lipido colloid technology sterile self -adherent patented TLC matrix (lipido colloid technology) wound contact layer combined with absorbent polyurethane foam pad , a superabsorbent layer ,a vapour permeable waterproof outer film with soft silicone adhesive border on the edges for atraumatic removal and repositioning of dressing. |
| 621 | Sterile Self adherent with Lipido colloid technology sterile self -adherent patented TLC matrix (lipido colloid technology) wound contact layer combined with absorbent polyurethane foam pad , a superabsorbent layer ,a vapour permeable waterproof outer film with soft silicone adhesive border on the edges for atraumatic removal and repositioning of dressing. |
| 622 | Sterile Self adherent with Lipido colloid technology sterile self -adherent patented TLC matrix (lipido colloid technology) wound contact layer combined with absorbent polyurethane foam pad , a superabsorbent layer ,a vapour permeable waterproof outer film with soft silicone adhesive border on the edges for atraumatic removal and repositioning of dressing. |
| 623 | Sterile Self adherent with Lipido colloid technology sterile self -adherent patented TLC matrix (lipido colloid technology) wound contact layer combined with absorbent polyurethane foam pad , a superabsorbent layer ,a vapour permeable waterproof outer film with soft silicone adhesive border on the edges for atraumatic removal and repositioning of dressing. |
| 624 | Sterile Self adherent with Lipido colloid technology sterile self -adherent patented TLC matrix (lipido colloid technology) wound contact layer combined with absorbent polyurethane foam pad , a superabsorbent layer ,a vapour permeable waterproof outer film with soft silicone adhesive border on the edges for atraumatic removal and repositioning of dressing. |
| 625 | 100% Polysiloxane based scar management in Gel form Pure Poly Siloxane based silicone scar management product in sheet form(we also should mention about the 100% Poly siloxane and Nylon polyamide mesh) |
| 626 | Triple Hydrocolloid Skin Barrier where no Cutting is required comprised of Pectin, Gelatin and Sodium Carboxy Methyl Cellulose,elastomeric polymers extending Turtlenecking Effect and rebounding memory technology with Audible Click and Flexible Tape Collar. |
| 627 | Triple Hydrocolloid Skin Barrier where no Cutting is required comprised of Pectin, Gelatin and Sodium Carboxy Methyl Cellulose,elastomeric polymers extending Turtlenecking Effect and rebounding memory technology with Audible Click and Flexible Tape Collar. |
| 628 | Triple Hydrocolloid Skin Barrier where no Cutting is required comprised of Pectin, Gelatin and Sodium Carboxy Methyl Cellulose,elastomeric polymers extending Turtlenecking Effect and rebounding memory technology with Audible Click and Flexible Tape Collar. |
| 629 | Drainable Pouch 12\\", with Filter Embeded & 2 Sided Hydrophobic comfort panel Standard, Opaque with Integrated dotted Velcro Tail Closure |
| 630 | Drainable Pouch 12\\", with Filter Embeded & 2 Sided Hydrophobic comfort panel Standard, Opaque with Integrated dotted Velcro Tail Closure |
| 631 | Drainable Pouch 12\\", with Filter Embeded & 2 Sided Hydrophobic comfort panel Standard, Opaque with Integrated dotted Velcro Tail Closure |
| 632 | Sulu Stepped Cartridges for variable tissue application , fixed anvil , different leg length staples in same cartridge , inbuilt knife ,size 60 mm inner to outer side 3.0,3.5 and 4.0 mm , purple colour code, USFDA Approved |
| 633 | Titanium Total Ossocular Replacement Prosthesis (TORP) |
| 634 | Titanium Partial Ossocular Replacement Prosthesis (PORP) |
| 635 | PISTON Titanium (0.4mm ) Diameter |
| 636 | PISTON Titanium (0.4mm ) Diameter |
| 637 | PISTON Titanium (0.4mm) Diameter |
| 638 | PISTON Titanium (0.4mm ) Diameter |
| 639 | PISTON Titanium (0.6mm) Diameter |
| 640 | PISTON Titanium (0.6mm) Diameter |
| 641 | PISTON Titanium (0.6mm) Diameter |
| 642 | PISTON Titanium (0.6mm) Diameter |
| 643 | PISTON Titanium - Teflon mix (0.4mm ) Diameter |
| 644 | PISTON Titanium - Teflon mix (0.4mm ) Diameter |
| 645 | PISTON Titanium - Teflon mix (0.4mm ) Diameter |
| 646 | PISTON Titanium - Teflon mix (0.4mm ) Diameter |
| 647 | PISTON Titanium - Teflon mix (0.6mm) Diameter |
| 648 | PISTON Titanium - Teflon mix (0.6mm) Diameter |
| 649 | PISTON Titanium - Teflon mix (0.6mm) Diameter |
| 650 | PISTON Titanium - Teflon mix (0.6mm) Diameter |
| 651 | PISTON Teflon (PTFE) (0.4mm ) Diameter |
| 652 | PISTON Teflon (PTFE) (0.4mm ) Diameter |
| 653 | PISTON Teflon (PTFE) (0.4mm) Diameter |
| 654 | PISTON Teflon (PTFE) (0.4mm ) Diameter |
| 655 | PISTON Teflon (PTFE) (0.6mm) Diameter |
| 656 | PISTON Teflon (PTFE) (0.6mm) Diameter |
| 657 | PISTON Teflon (PTFE) (0.6mm) Diameter |
| 658 | PISTON Teflon (PTFE) (0.6mm) Diameter |
| 659 | Burr Tips (Tungeston Carbide material) Round Tip (70 mm length) - Cutting 0.5 mm |
| 660 | Burr Tips (Tungeston Carbide material) Round Tip (70 mm length) - Cutting 0.6 mm |
| 661 | Burr Tips (Tungeston Carbide material) Round Tip (70 mm length) - Cutting /0.8 mm |
| 662 | Burr Tips (Tungeston Carbide material) Round Tip (70 mm length) - Cutting 1.6 mm |
| 663 | Burr Tips (Tungeston Carbide material) Round Tip (70 mm length) - Cutting 2.3 mm |
| 664 | Burr Tips (Tungeston Carbide material) Round Tip (70 mm length) - Cutting 2.8 mm |
| 665 | Burr Tips (Tungeston Carbide material) Round Tip (70 mm length) - Cutting 3 mm |
| 666 | Burr Tips (Tungeston Carbide material) Round Tip (70 mm length) - Cutting 3.5 mm |
| 667 | Burr Tips (Tungeston Carbide material) Round Tip (70 mm length) - Cutting 4 mm |
| 668 | Burr Tips (Tungeston Carbide material) Round Tip (70 mm length) - Cutting 5 mm |
| 669 | Burr Tips (Tungeston Carbide material) Round Tip (70 mm length) - Diamond 0.5 mm |
| 670 | Burr Tips (Tungeston Carbide material) Round Tip (70 mm length) - Diamond 0.6 mm |
| 671 | Burr Tips (Tungeston Carbide material) Round Tip (70 mm length) - Diamond /0.8 mm |
| 672 | Burr Tips (Tungeston Carbide material) Round Tip (70 mm length) - Diamond 1.6 mm |
| 673 | Burr Tips (Tungeston Carbide material) Round Tip (70 mm length) - Diamond 2.3 mm |
| 674 | Burr Tips (Tungeston Carbide material) Round Tip (70 mm length) - Diamond 2.8 mm |
| 675 | Burr Tips (Tungeston Carbide material) Round Tip (70 mm length) - Diamond 3 mm |
| 676 | Burr Tips (Tungeston Carbide material) Round Tip (70 mm length) - Diamond 3.5 mm |
| 677 | Burr Tips (Tungeston Carbide material) Round Tip (70 mm length) - Diamond 4 mm |
| 678 | Burr Tips (Tungeston Carbide material) Round Tip (70 mm length) - Diamond 5 mm |
| 679 | Burr Tips (Tungeston Carbide material) Round Tip - Fissure Burr 70 mm to 95 mm length 1 mm |
| 680 | Burr Tips (Tungeston Carbide material) Round Tip - Fissure Burr 70 mm to 95 mm length 3, mm |
| 681 | Burr Tips (Tungeston Carbide material) Round Tip - Fissure Burr 70 mm to 95 mm length 5 mm |
| 682 | Sialestic Sheet 55x75 mm and thickness 0.5 mm |
| 683 | Ear Pack/Wick (12x24 mm length) |
| 684 | T-Tube (Silicone) 9 mm length |
| 685 | Nasal Haemostatic sponge pack With out Airway 8 inch |
| 686 | Nasal Haemostatic sponge pack With out Airway 10 inch |
| 687 | Nasal Haemostatic sponge Pack (With Airway) 8 inch |
| 688 | Tracheostomy Tube (PVC material) Double Lumen 3.5 -8MM All size |
| 689 | Tracheostomy Tube (PVC material) Fenestrated 3.5 -8MM All size |
| 690 | Femoral sheath including Pott’s needle, J tipped wire, dilator and sheath ALL SIZES |
| 691 | Femoral sheath including Pott’s needle, J tipped wire, dilator and sheath ALL SIZES |
| 692 | Femoral sheath including Pott’s needle, J tipped wire, dilator and sheath ALL SIZES |
| 693 | Femoral sheath including Pott’s needle, J tipped wire, dilator and sheath ALL SIZES |
| 694 | Femoral sheath including Pott’s needle, J tipped wire, dilator and sheath ALL SIZES |
| 695 | Diagnostic Catheter AR 1 Aka Amplatz right |
| 696 | Diagnostic Catheter AR 1 Aka Amplatz right |
| 697 | Diagnostic Catheter VERT angled tip 125cm |
| 698 | Diagnostic Catheter SIM 1 aka simmon’s |
| 699 | Diagnostic Catheter SIM 1 aka simmon’s |
| 700 | Diagnostic Catheter SIM 2 aka simmon |
| 701 | Diagnostic Catheter SIM 3 aka simmon |
| 702 | Diagnostic Catheter H 1 aka headhunter |
| 703 | Diagnostic Catheter Pigtail |
| 704 | Guide wire hydrophilic coated angled tip soft regular standard |
| 705 | Guide wire hydrophilic coated angled tip extra stiff |
| 706 | Guiding Catheter Braided Guiding catheter in various shapes |
| 707 | Guiding Catheter Braided Guiding catheter in various shapes |
| 708 | Guiding Catheter Braided Guiding catheter in various shapes |
| 709 | Guiding Catheter Braided Guiding catheter in various shapes |
| 710 | Guiding Catheter Braided Guiding catheter in various shapes |
| 711 | Guiding Catheter Braided Guiding catheter in various shapes |
| 712 | Guiding Catheter Balloon tipped guiding catheter size |
| 713 | Distal Access Catheter |
| 714 | Distal Access Catheter |
| 715 | Intracranial Support Catheter with flat soft distal segment |
| 716 | Intracranial Support Catheter with flat soft distal segment |
| 717 | Flexometlic Tube 3-8.5 with stylet Reinforce ET Tube with wiring from tip to end it should be approved by *US FDA |
| 718 | ACT TUBES US FDA + CE/ DGCI APPROVED· Disposable ACT tubes compatible with existing Medtronic machines at SMSH· Should meet highest medical industrial standards· Quality certification should be provided from authorized agencies. |
| 719 | HIGH – PRESURE INJECTOR LINES US FDA + CE/ DGCI PPROVED· Should be available in various lengths· Should have male and female luer locks· Should be transparent and kink resistant· Should be able to take high pressure of angiographic injections |
| 720 | DISPOSABLE TRANSDUCERS FOR INVASIVE PRESSURE MONITORING COMPATIBLE WITH AVAILABLE SYSTEM IN CATH LAB IN SMSH US FDA + CE/ DGCI APPROVED• Disposable transducers for invasive pressure monitoring• Should be compatible with available system in Cath Lab (IABP – Data Scope & Cath Lab transducer) and ICCU at SMSH• Should meet highest medical industrial standards• Quality certification should be provided form authorized agencies |
| 721 | RENAL DOUBLE CURVE CATHETER US FDA + CE/ DGCI APPROVED· |
| 722 | SIMMONS/ SIDEWINDER CATHETER US FDA + CE/ DGCI APPROVED· |
| 723 | VERTEBRAL CATHETER |
| 724 | COELIAC AXIS CATHETER US FDA + CE/ DGCI APPROVED· |
| 725 | SHEPHERD’S HOOK CATHETER US FDA + CE/ DGCI APPROVED· |
| 726 | VTK DIAGNOSTIC CATHETER US FDA + CE/ DGCI APPROVED· |
| 727 | ANGIOGRAPHIC SIZING PIGTAIL CATHETER 5Fr US FDA + CE/ DGCI APPROVED |
| 728 | ANGIOGRAPHIC SIZING PIGTAIL CATHETER 6Fr US FDA + CE/ DGCI APPROVED |
| 729 | ANGIOGRAPHIC SIZING PIGTAIL CATHETER 7Fr US FDA + CE/ DGCI APPROVED |
| 730 | Balloon inflation catheter for BRTO USA/FDA/CE approved 9/10 f 0.035 \\"compatible ,length100/120 cm ,max volume 30/40 cc |
| 731 | Dialyzer (dialyzer should be synthetic membran(poly sulfon/poly ethresulfon) |
| 732 | Dialyzer (dialyzer should be synthetic membran(poly sulfon/poly ethresulfon) |
| 733 | Dialyzer (dialyzer should be synthetic membran(poly sulfon/poly ethresulfon) |
| 734 | Dialyzer (dialyzer should be synthetic membran(poly sulfon/poly ethresulfon) |
| 735 | Pediatric dialyzer (dialyzer should be synthetic membran(poly sulfon/poly ethresulfon) |
| 736 | Pediatric dialyzer (dialyzer should be synthetic membran(poly sulfon/poly ethresulfon) |
| 737 | Multirate Elastomeric disposable infusion pump with Air vent Blue end cap for air bubble removal and with two micro IV filters in 100 ml & 275 ml with flow rate from 1-7/hr and 2- 14ml/hr |
| 738 | Single rate Elastomeric disposable infusion pump with Air vent Blue end cap for air bubble removal and with two micro IV filters in 100 ml & 275 ml with flow rate of 2,5,8,10ml/hr |
| 739 | PCT KIT WITH GRIGGS FORCEPS AND WITH SUBGLOTIC SUCTION LINE TRACHEOSTOMY TUBE WITH USFDA/EUROPEAN CE |
| 740 | PCT KIT WITHOUT GRIGGS FORCEPS AND WITH SUBGLOTIC SUCTION LINE TRACHEOSTOMY TUBE WITH USFDA/EUROPEAN CE |
| 741 | Double lumen closed suction set for ET and TT , With MDI Adopter , Trach wedge , swiel connector and with reservoir |
| 742 | ET Tube with yellow subglotic suction line with inverted and Soft seal cuff. WITH USFDA/EUROPEAN CE |
| 743 | TT Tube with yellow sub glotic suction line with inverted and Soft seal cuff. WITH USFDA/EUROPEAN CE |
| 744 | Catheter stabilization device Sterile latex free sutureless with sliding post |
| 745 | TITANIUM MAXILLOFACIAL FRACTURE FIXATION MINIPLATE 2.5 MM |
| 746 | TITANIUM MAXILLOFACIAL FRACTURE FIXATION MINIPLATE 2.0 MM |
| 747 | TITANIUM MAXILLOFACIAL FRACTURE FIXATION MINIPLATE 1.5 MM |
| 748 | TITANIUM MAXILLOFACIAL FRACTURE FIXATION MINIPLATE 1.5 MM C PLATE |
| 749 | TITANIUM MAXILLOFACIAL FRACTURE FIXATION MINIPLATE 2.5 MM L PLATE RIGHT AND LEFT SIDE |
| 750 | TITANIUM MAXILLOFACIAL FRACTURE FIXATION MINIPLATE 2.0 MM L PLATE RIGHT AND LEFT SIDE |
| 751 | TITANIUM MAXILLOFACIAL FRACTURE FIXATION SCREWS 1.5 MM |
| 752 | TITANIUM MAXILLOFACIAL FRACTURE FIXATION SCREWS 2.0 MM |
| 753 | TITANIUM MAXILLOFACIAL FRACTURE FIXATION SCREWS 2.5 MM |
| 754 | Nitrile Gloves Non Sterlite Powder Free Minimum 280mm length White/blue color, polyacrylate coated nitrile examination gloveAbsence of residual accelerator - Zinc Dibutyl Dithiocarbamate a) Minimum puncture resistance force 6.86Nb) Absence of common allergens (micro-gram/g)– Hev b 1, Hev b 3, Hev b 5 & Hev b 6.02 |
| 755 | Nitrile Gloves Non Sterlite Powder Free Minimum 280mm length White/blue color, polyacrylate coated nitrile examination gloveAbsence of residual accelerator - Zinc Dibutyl Dithiocarbamate a) Minimum puncture resistance force 6.86Nb) Absence of common allergens (micro-gram/g)– Hev b 1, Hev b 3, Hev b 5 & Hev b 6.02 |
| 756 | Absorbable Gelatin Sponge IP 66, Size 80(+-10) mm x 50 mm x 10 mm should be sterlized. |
| 757 | Absorbent Cotton Wool IP 500 gm |
| 758 | Asepto Syringe with Transparent Bulb Sterile, 60 ml |
| 759 | Blood Administration Set / Blood Transfusion Set • Sharp and easy piercing spike suitable for blood bags and standard blood containers• Transparent cylindrical drip chamber with filter.Filter size should be 200+20 micrometer.• 150 cm long smooth kink resistant tubing• Efficient roller clamp to control and adjust the transfusion rate• Should conform to IS 9824(Part 3):1996 |
| 760 | Disposable Sterile Surgical Rubber Gloves Size 6 ½ Inches• Made of natural rubber Latex, powdered, without tear, properly folded in a paper• Free of holes, with Acceptable Quality Level (AQL) of 1.5 or less• Tensile strength as per EN 455-2• Powder should be non-allergenic• should Conform to IS 13422• ISI marked / CE certified / FDA approved |
| 761 | Disposable Sterile Surgical Rubber Gloves Size 6 ½ Inches• Made of natural rubber Latex, powder free (Polymer /Silicon Coated), without tear, properly folded in a paper• Free of holes, with Acceptable Quality Level (AQL) of 1.5 or less• Tensile strength as per EN 455-2• should Conform to IS 13422ISI marked / CE certified / FDA approved (CE Certification / FDA Approval for item is mandatory for importer firms, that cannot avail IS Standards) |
| 762 | Disposable Sterile Surgical Rubber Gloves Size 7 Inches• Made of natural rubber Latex, powdered,,without tear, properly folded in a paper• Free of holes, with Acceptable Quality Level (AQL) of 1.5 or less• Tensile strength as per EN 455-2• Powder should be non-allergenic • should Conform to IS 13422• ISI marked / CE certified / FDA approved |
| 763 | Disposable Sterile Surgical Rubber Gloves Size 7 Inches• Made of natural rubber Latex, powder free (Polymer /Silicon Coated), without tear, properly folded in a paper • Free of holes, with Acceptable Quality Level (AQL) of 1.5 or less• Tensile strength as per EN 455-2• should Conform to IS 13422ISI marked / CE certified / FDA approved (CE Certification / FDA Approval for item is mandatory for importer firms, that cannot avail IS Standards) |
| 764 | Disposable Sterile Surgical Rubber Gloves Size 7½ Inches• Made of natural rubber Latex, powdered, without tear, properly folded in a paper• Free of holes, with Acceptable Quality Level (AQL) of 1.5 or less• Tensile strength as per EN 455-2• Powder should be non-allergenic• should Conform to IS 13422• ISI marked / CE certified / FDA approved |
| 765 | Disposable Sterile Surgical Rubber Gloves Size 7 ½ Inches• Made of natural rubber Latex, powder free (Polymer /Silicon Coated), without tear, properly folded in a paper• Free of holes, with Acceptable Quality Level (AQL) of 1.5 or less• Tensile strength as per EN 455-2• should Conform to IS 13422ISI marked / CE certified / FDA approved (CE Certification / FDA Approval for item is mandatory for importer firms, that cannot avail IS Standards |
| 766 | Suction Catheter, Sterile. Size: FG 5 (For use in respiratory tract)• Soft, kink resistant tubing• Rounded open tip with lateral eye• Colour coded universal funnel connector for safe connection to standard suction equipment• Length 50 cm (min.)• Should conform to IS0 8836:2014 |
| 767 | Suction Catheter, Sterile. Size: FG 6 (For use in respiratory tract)• Soft, kink resistant tubing• Rounded open tip with lateral eye• Colour coded universal funnel connector for safe connection to standard suction equipment• Length 50 cm (min.)• Should conform to IS0 8836:2014 |
| 768 | Suction Catheter, Sterile. Size: FG 8 (For use in respiratory tract)• Soft, kink resistant tubing• Rounded open tip with lateral eye• Colour coded universal funnel connector for safe connection to standard suction equipment• Length 50 cm (min.)• Should conform to IS0 8836:2014 |
| 769 | Suction Catheter, Sterile. Size: FG 10 (For use in respiratory tract)• Soft, kink resistant tubing• Rounded open tip with lateral eye• Colour coded universal funnel connector for safe connection to standard suction equipment• Length 50 cm (min.)• Should conform to IS0 8836:2014 |
| 770 | Suction Catheter, Sterile. Size: FG 12 (For use in respiratory tract)• Soft, kink resistant tubing• Rounded open tip with lateral eye• Colour coded universal funnel connector for safe connection to standard suction equipment• Length 50 cm (min.)• Should conform to IS0 8836:2014 |
| 771 | Suction Catheter, Sterile. Size: FG 14 (For use in respiratory tract)• Soft, kink resistant tubing• Rounded open tip with lateral eye• Colour coded universal funnel connector for safe connection to standard suction equipment• Length 50 cm (min.)• Should conform to IS0 8836:2014 |
| 772 | Suction Catheter, Sterile. Size: FG 16 (For use in respiratory tract)• Soft, kink resistant tubing• Rounded open tip with lateral eye• Colour coded universal funnel connector for safe connection to standard suction equipment• Length 50 cm (min.)• Should conform to IS0 8836:2014 |
| 773 | Suction Catheter, Sterile. Size: FG 18 (For use in respiratory tract)• Soft, kink resistant tubing• Rounded open tip with lateral eye• Colour coded universal funnel connector for safe connection to standard suction equipment• Length 50 cm (min.)• Should conform to IS0 8836:2014 |
| 774 | Suction Catheter, Sterile. Size: FG 20 (For use in respiratory tract)• Soft, kink resistant tubing• Rounded open tip with lateral eye• Colour coded universal funnel connector for safe connection to standard suction equipment• Length 50 cm (min.)• Should conform to IS0 8836:2014 |
| 775 | Suction Catheter, Sterile. Size: FG 22 (For use in respiratory tract)• Soft, kink resistant tubing• Rounded open tip with lateral eye• Colour coded universal funnel connector for safe connection to standard suction equipment• Length 50 cm (min.)• Should conform to IS0 8836:2014 |
| 776 | Sterile Catheter, Single Use, for Urinary Drainage (Foley Balloon Catheter), 2 Way, Size 8 FG• Made of Silicone elastomer bonded with Latex• Should have hard plastic valve• Smooth distal end with smooth eyes for atraumatic intubation• Symmetrical foley balloon• Balloon capacity 3- 5 ml• Should conform to IS 11497• Color coding marking to identify size • Length, wall thickness and balloon capacity should be mentioned as per IS 11497.• Specification for B,C,D,E,F,G should be mentioned as per IS 11497 for particular size |
| 777 | Sterile Catheter, Single Use, for Urinary Drainage (Foley Balloon Catheter), 2 Way, Size10 FG• Made of Silicone elastomer bonded with Latex• Should have hard plastic valve• Smooth distal end with smooth eyes for atraumatic intubation• Symmetrical foley balloon• Balloon capacity 3- 5 ml• Should conform to IS 11497• Color coding marking to identify size • Length, wall thickness and balloon capacity should be mentioned as per IS 11497.• Specification for B,C,D,E,F,G should be mentioned as per IS11497 for particular size |
| 778 | Sterile Catheter, Single Use, for Urinary Drainage (Foley Balloon Catheter), 2 Way, Size16 FG• Made of Silicone elastomer bonded with Latex• Should have hard plastic valve• Smooth distal end with smooth eyes for atraumatic intubation• Symmetrical foley balloon• Balloon capacity 30 ± 1ml• Should conform to IS 11497• Color coding marking to identify size • Length, wall thickness and balloon capacity should be mentioned as per IS 11497.• Specification for B,C,D,E,F,G should be mentioned as per IS11497 for particular size |
| 779 | Sterile Catheter, Single Use, for Urinary Drainage (Foley Balloon Catheter), 2 Way, Size18 FG• Made of Silicone elastomer bonded with Latex• Should have hard plastic valve• Smooth distal end with smooth eyes for atraumatic intubation• Symmetrical foley balloon• Balloon capacity 30 ± 1 ml• Should conform to IS 11497 • Color coding marking to identify size • Length, wall thickness and balloon capacity should be mentioned as per IS 11497.• Specification for B,C,D,E,F,G should be mentioned as per IS11497 for particular size |
| 780 | Sterile Catheter, Single Use, for Urinary Drainage (Foley Balloon Catheter), 2 Way, Size20 FG• Made of Silicone elastomer bonded with Latex• Should have hard plastic valve• Smooth distal end with smooth eyes for atraumatic intubation• Symmetrical foley balloon• Balloon capacity 30 ± 1 ml• Should conform to IS 11497 • Color coding marking to identify size • Length, wall thickness and balloon capacity should be mentioned as per IS 11497.• Specification for B,C,D,E,F,G should be mentioned as per IS11497 for particular size |
| 781 | Sterile Catheter, Single Use, for Urinary Drainage (Foley Balloon Catheter), 2 Way, Size22 FG• Made of Silicone elastomer bonded with Latex• Should have hard plastic valve• Smooth distal end with smooth eyes for atraumatic intubation• Symmetrical foley balloon• Balloon capacity 30 ± 1 ml• Should conform to IS 11497 • Color coding marking to identify size • Length, wall thickness and balloon capacity should be mentioned as per IS 11497.• Specification for B,C,D,E,F,G should be mentioned as per IS11497 for particular size |
| 782 | Sterile Catheter, Single Use, for Urinary Drainage (Foley Balloon Catheter), 2 Way, Size 24 FG• Made of Silicone elastomer bonded with Latex• Should have hard plastic valve• Smooth distal end with smooth eyes for atraumatic intubation• Symmetrical foley balloon• Balloon capacity 30 ± 1 ml• Should conform to IS 11497 • Color coding marking to identify size • Length, wall thickness and balloon capacity should be mentioned as per IS 11497.• Specification for B,C,D,E,F,G should be mentioned as per IS11497 for particular size |
| 783 | Infant Feeding Tube Size:10FG length 50 cm (min.)• Two lateral eyes at distal end• Soft, kink resistant non-toxic PVC tubing, non irritant to delicate mucosa• With female flexible mount with in-built closure• Radio opaque line• Sterile |
| 784 | Infant Feeding Tube Size:8FG, length 50 cm (min.)• Two lateral eyes at distal end• Soft, kink resistant non-toxic PVC tubing, non irritant to delicate mucosa• With female flexible mount with in-built closure• Radio opaque line• Sterile |
| 785 | Infant Feeding Tube Size:5FG length 50 cm (min.)• Two lateral eyes at distal end• Soft, kink resistant non-toxic PVC tubing, non irritant to delicate mucosa• With female flexible mount with in-built closure• Radio opaque line• Sterile |
| 786 | Sterile Disposable Perfusion Set with Airway and Needle (Adult Use)• For gravity feed only• Sharp and easy piercing spike with air vent• Transparent and flexible drip chamber• 150 cm long smooth kink resistant tubing• Self sealing latex bulb which will also act as an port for extra medication• Efficient roller clamp to control and adjust the fluid rate• 21 G needle• Should conform to IS 12655 -4 standard |
| 787 | Sterile Disposable Perfusion Set (Infusion set) with Airway and Needle (Paediatric Use)• Burette type measured volume chamber of 100 ml• Drop size of approx 60 drops per ml• Injection port,latexfree, for intermittent medication.• Floating auto shut off valve (latex free) in burette.• Soft and kink resistant PVC tubing.• Roller controller for flow control• Tube length 150 cm• 23G needle • Should conform to ISO 8536-5 |
| 788 | Sterile Disposable Infusion Set with Microdrip (I.V.)• Microdrip Infusion set with drop size reduced to approx 60 drops per ml• Sharp and easy piercing spike• Transparent and flexible drip chamber • 150 cm long smooth kink resistant tubing • Efficient roller clamp to control and adjust the fluid rate• Should conform to IS 12655 - 4 standard |
| 789 | Insulin syringe ( 40 units) with (fixed) 30 G needleShall conform to IS 12227 |
| 790 | Sterile Disposable (Single Use) Teflon / PTFE I.V. Cannula with integrated 3 Way stop cock. Size 16G• Should be packed in transparent, single blister pack.• Should conform to IS 10555 standard |
| 791 | Sterile Disposable (Single Use Teflon / PTFE I.V. Cannula with integrated 3 Way stop cock. ) Size 18G• Should be packed in transparent, single blister pack.• Should conform to IS 10555 standard |
| 792 | Sterile Disposable (Single Use) Teflon / PTFE I.V. Cannula with integrated 3 Way stop cock. Size 20G• Should be packed in transparent, single blister pack.• Should conform to IS 10555 standard |
| 793 | Sterile Disposable (Single Use) Teflon / PTFE I.V. Cannula with integrated 3 Way stop cock. Size 22G• Should be packed in transparent, single blister pack.• Should conform to IS 10555 standard |
| 794 | Sterile Disposable (Single Use) Teflon/ PTFE I.V. Cannula without port. Size 24G• Suitable for paediatric & neonatal use• Should be packed in transparent, single blister pack.• Should conform to IS 10555 standard |
| 795 | Mucus Extractor Sterile• Clear transparent container• Antibacterial filter• Soft, kink resistant PVC tubing• Tube Size 10 FG; Length 40 cm (min.)• Capacity 25 ml |
| 796 | Nasal Oxygen Cannula (Set), Twin Bore (accessory forcompressed air breathing) All Sizes (Adult) • Soft and kink resistant PVC tubing• Multichannel / star lumen to preventing accidental kinking• Twin bores should ensure equal volume of oxygen to both air passages• Connector for easy connection to the oxygen source• Tube length 200 cm |
| 797 | Nasal Oxygen Cannula (Set), Twin Bore (accessory forcompressed air breathing) All Sizes (Pediatrics) • Soft and kink resistant PVC tubing• Multichannel / star lumen to preventing accidental kinking• Twin bores should ensure equal volume of oxygen to both air passages• Connector for easy connection to the oxygen source• Tube length 200 cm |
| 798 | Paper Adhesive Plaster 1\\" X 9.0 mts (with cutter) Non woven adhesive tape,hypoallergic,should have some stretch bonding |
| 799 | Paper Adhesive Plaster 2\\" X 9.0 mts (with cutter) Non woven adhesive tape hypoallergic, should have some stretch bonding |
| 800 | Paper Adhesive Plaster 3\\" X 9.0 mts (with cutter) Non woven adhesive tape hypoallergic, should have some stretch bonding |
| 801 | Plaster of Paris Bandages 15cm X 2.7mts / RollShould conform to Schedule F(II) of Drug and Cosmetic Act 1940 |
| 802 | Plaster of Paris Bandages 10cm X 2.7mts / RollShould conform to Schedule F(II) of Drug and Cosmetic Act 1940 |
| 803 | Ryle's Tube / Nasogastric Tube (P.V.C.) with radio opaque lining. Size: 10• Soft, kink resistant PVC tubing for atraumatic intubation• Closed distal end should be coned with radio opaque material for accurate intubation• Four lateral eyes for greater efficiency• Radio opaque line• Marking at 50, 60, 70 cm from tip• Colour coded funnel• With luer connector / closure• Length 105 cm |
| 804 | Ryle's Tube / Nasogastric Tube (P.V.C.) with radio opaque lining. Size: 12• Soft, kink resistant PVC tubing for atraumatic intubation• Closed distal end should be coned with radio opaque material for accurate intubation• Four lateral eyes for greater efficiency• Radio opaque line• Marking at 50, 60, 70 cm from tip• Colour coded funnel• With luer connector / closure• Length 105 cm |
| 805 | Ryle's Tube / Nasogastric Tube (P.V.C.) with radio opaque lining. Size: 14• Soft, kink resistant PVC tubing for atraumatic intubation• Closed distal end should be coned with radio opaque material for accurate intubation• Four lateral eyes for greater efficiency• Radio opaque line• Marking at 50, 60, 70 cm from tip • Colour coded funnel• With luer connector / closure• Length 105 cm |
| 806 | Ryle's Tube / Nasogastric Tube (P.V.C.) with radio opaque lining. Size: 16• Soft, kink resistant PVC tubing for atraumatic intubation• Closed distal end should be coned with radio opaque material for accurate intubation• Four lateral eyes for greater efficiency• Radio opaque line• Marking at 50, 60, 70 cm from tip• Colour coded funnel• With luer connector / closure• Length 105 cm |
| 807 | Ryle's Tube / Nasogastric Tube (P.V.C.) with radio opaque lining. Size: 18• Soft, kink resistant PVC tubing for atraumatic intubation• Closed distal end should be coned with radio opaque material for accurate intubation• Four lateral eyes for greater efficiency• Radio opaque line• Marking at 50, 60, 70 cm from tip• Colour coded funnel• With luer connector / closure• Length 105 cm |
| 808 | Scalp Vein Set (Disposable): Size 18G • Butterfly shaped wings for easy handling and attachment with skin. Colour coded• Needle should be bevelled, siliconised and should ensure atraumatic cannulation• Female luer fitting at one end• Soft, kink resistant, non-toxic, non irritant tube• Sterile |
| 809 | Scalp Vein Set (Disposable): Size 20G • Butterfly shaped wings for easy handling and attachment with skin. Colour coded• Needle should be bevelled, siliconised and should ensure atraumatic cannulation• Female luer fitting at one end• Soft, kink resistant, non-toxic, non irritant tube• Sterile |
| 810 | Scalp Vein Set (Disposable): Size 22G • Butterfly shaped wings for easy handling and attachment with skin. Colour coded• Needle should be bevelled, siliconised and should ensure atraumatic cannulation• Female luer fitting at one end• Soft, kink resistant, non-toxic, non irritant tube• Sterile |
| 811 | Scalp Vein Set (Disposable): Size 24G • Butterfly shaped wings for easy handling and attachment with skin. Colour coded• Needle should be bevelled, siliconised and should ensure atraumatic cannulation• Female luer fitting at one end• Soft, kink resistant, non-toxic, non irritant tube• Sterile |
| 812 | Sterile Hypodermic Syringe with Needle attached, 24G, Single Use - 2 ml• Clear transparent chamber• Prominent graduation• Inert material gasket at the piston to minimise friction during movement & prevent leakage and back flow• Sharp needle ensuring minimum trauma during penetration• Shall conform to IS 12050• Packing: Needle should be attached with the syringe and packed in unit ribbon pack• The words \\"DESTROY AFTER SINGLE USE\\" or equivalent should be written on Unit Container |
| 813 | Sterile Hypodermic Syringe with Needle attached, 24G, Single Use - 5 ml• Clear transparent chamber• Prominent graduation• Inert material gasket at the piston to minimise friction during movement & prevent leakage and back flow• Sharp needle ensuring minimum trauma during penetration• Shall conform to IS 12050• Packing: Needle should be attached with the syringe and packed in unit ribbon pack• The words \\"DESTROY AFTER SINGLE USE\\" or equivalent should be written on Unit Container. |
| 814 | Sterile Hypodermic Syringe with Needle attached, 22G, Single Use - 10 ml• Clear transparent chamber• Prominent graduation• Inert material gasket at the piston to minimise friction during movement & prevent leakage and back flow• Sharp needle ensuring minimum trauma during penetration• Shall conform to IS 12050• Packing: Needle should be attached with the syringe and packed in unit ribbon pack• The words \\"DESTROY AFTER SINGLE USE\\" or equivalent should be written on Unit Container. |
| 815 | Sterile Hypodermic Syringe with Needle attached, 22G, Single Use - 20 ml• Clear transparent chamber• Prominent graduation• Inert material gasket at the piston to minimise friction during movement & prevent leakage and back flow• Sharp needle ensuring minimum trauma during penetration• Shall conform to IS 12050• Packing: Needle should be attached with the syringe and packed in unit ribbon pack• The words \\"DESTROY AFTER SINGLE USE\\" or equivalent should be written on Unit Container. |
| 816 | Surgical Blade Sterile, Size 11• Single peel pack in metal foil• The tip of the blade shall be well defined, central and sharp. There shall be no waviness, jags, feathers, nicks, or other defects on the cutting edge. The surfaces of the blade shall be smooth and free from tool marks and any sign of corrosion. • Should conform to IS 3319 |
| 817 | Surgical Blade Sterile, Size 15• Single peel pack in metal foil• The tip of the blade shall be well defined, central and sharp. There shall be no waviness, jags, feathers, nicks, or other defects on the cutting edge. The surfaces of the blade shall be smooth and free from tool marks and any sign of corrosion. • Should conform to IS 3319 |
| 818 | Surgical Blade Sterile, Size 22• Single peel pack in metal foil• The tip of the blade shall be well defined, central and sharp. There shall be no waviness, jags, feathers, nicks, or other defects on the cutting edge. The surfaces of the blade shall be smooth and free from tool marks and any sign of corrosion. • Should conform to IS 3319 |
| 819 | Suture Needles Curved 1/2 Circle Round Body Assorted Size 11-15• It should be mentioned whether needle is Pointed or blunt with type of its point.• Type of eye of the needle should be mentioned.• Should conform to IS-9165 |
| 820 | Suture Needles Curved 1/2 Circle Round Body Assorted Size 1-5• It should be mentioned whether needle is Pointed or blunt with type of its point.• Type of eye of the needle should be mentioned.• Should conform to IS-9165 |
| 821 | Suture Needles Curved 1/2 Circle Round Body Assorted Size 16-20• It should be mentioned whether needle is Pointed or blunt with type of its point.• Type of eye of the needle should be mentioned.• Should conform to IS-9165 |
| 822 | Suture Needles Curved 1/2 Circle Round Body Assorted Size 6-10• It should be mentioned whether needle is Pointed or blunt with type of its point.• Type of eye of the needle should be mentioned.• Should conform to IS-9165 |
| 823 | Suture Needles Curved And Cutting 1/2 Circle Cutting Size 6-10• It should be mentioned whether needle is Pointed or blunt with type of its point.• Type of eye of the needle should be mentioned.• Should conform to IS-9165 |
| 824 | Suture Needles Curved And Cutting 1/2 Circle Size 11-15• It should be mentioned whether needle is Pointed or blunt with type of its point.• Type of eye of the needle should be mentioned.• Should conform to IS-9165 |
| 825 | Suture Needles Curved And Cutting 1/2 Circle Size 16-20• It should be mentioned whether needle is Pointed or blunt with type of its point.• Type of eye of the needle should be mentioned.• Should conform to IS-9165 |
| 826 | Suture Needles Curved And Cutting Size 1-5• It should be mentioned whether needle is Pointed or blunt with type of its point.• Type of eye of the needle should be mentioned.• Should conform to IS-9165 |
| 827 | Sterile Disposable Spinal Needle for Single Use 22G x 3 ½ inch• Clear / transparent hub• Sharp tip which should ensure minimal puncture trauma |
| 828 | Sterile Disposable Spinal Needle for Single Use 25G x 3 ½ inch• Clear / transparent hub• Sharp tip which should ensure minimal puncture trauma |
| 829 | Urine Collecting Bag, Disposable 2000 ml• Transparent sheet• Kink resistant flexible tubing not less than 90 cm in length• should have non-return valve• Top drainage outlet• Graduated bag• Moulded handle for easy handling |
| 830 | Double J Stent, Sterile, Both Ends Open - size 4F, length 16 cm• Radio opaque• Should be of inert material, non- irritant to tissue |
| 831 | Double J Stent, Sterile, Both Ends Open, size 5F, length 20 cm• Radio opaque• Should be of inert material, non- irritant to tissue |
| 832 | Double J Stent, Sterile, One End Closed - size 4F, length 16 cm • Radio opaque• Should be of inert material, non- irritant to tissue |
| 833 | Double J Stent, Sterile, One End Closed, size 5F, length 20 cm• Radio opaque• Should be of inert material, non- irritant to tissue |
| 834 | Endotracheal Tube, Plain - Size 2.5mm• Transparent• Standard 15 mm connector at proximal end• Radio-opaque line throughout the length• Tip suitable for nasal and oral intubation• Single use, sterile |
| 835 | Endotracheal Tube, Plain - Size 3mm• Transparent• Standard 15 mm connector at proximal end• Radio-opaque line throughout the length• Tip suitable for nasal and oral intubation• Single use, sterile |
| 836 | Endotracheal Tube, Plain - Size 3.5mm• Transparent• Standard 15 mm connector at proximal end• Radio-opaque line throughout the length• Tip suitable for nasal and oral intubation• Single use, sterile |
| 837 | Endotracheal Tube, Plain - Size 4mm• Transparent• Standard 15 mm connector at proximal end• Radio-opaque line throughout the length• Tip suitable for nasal and oral intubation• Single use, sterile |
| 838 | Endotracheal Tube, Plain - Size 4.5mm• Transparent• Standard 15 mm connector at proximal end• Radio-opaque line throughout the length• Tip suitable for nasal and oral intubation• Single use, sterile |
| 839 | Endotracheal Tube, Plain - Size 5mm• Transparent• Standard 15 mm connector at proximal end• Radio-opaque line throughout the length• Tip suitable for nasal and oral intubation• Single use, sterile |
| 840 | Endotracheal Tube, Plain - Size 5.5mm• Transparent• Standard 15 mm connector at proximal end• Radio-opaque line throughout the length• Tip suitable for nasal and oral intubation• Single use, sterile |
| 841 | Endotracheal Tube, Plain with radio-opaque line, Sterile, Single Use - Size 6mm• Transparent• Standard 15 mm connector at proximal end• Radio-opaque line throughout the length• Tip suitable for nasal and oral intubation• Single use, sterile |
| 842 | Endotracheal Tube, Plain - Size 6.5mm• Transparent• Standard 15 mm connector at proximal end• Radio-opaque line throughout the length• Tip suitable for nasal and oral intubation• Single use, sterile |
| 843 | Endotracheal Tube, Plain - Size 7mm• Transparent• Standard 15 mm connector at proximal end• Radio-opaque line throughout the length• Tip suitable for nasal and oral intubation• Single use, sterile |
| 844 | Endotracheal Tube, Plain - Size 7.5mm• Transparent• Standard 15 mm connector at proximal end• Radio-opaque line throughout the length• Tip suitable for nasal and oral intubation• Single use, sterile |
| 845 | Endotracheal Tube, Plain - Size 8mm• Transparent• Standard 15 mm connector at proximal end• Radio-opaque line throughout the length• Tip suitable for nasal and oral intubation• Single use, sterile |
| 846 | Endotracheal Tube, Plain - Size 8.5mm• Transparent• Standard 15 mm connector at proximal end• Radio-opaque line throughout the length• Tip suitable for nasal and oral intubation• Single use, sterile |
| 847 | Endotracheal Tube, Cuffed - Size 4mm• Soft cuff towards the distal end• Kink resistant inflation tube• Murphy eye at distal end with polished smoothness• Radio-opaque line• Standard 15 mm connector• Sterile, single use• Curved shaped blister pack – suiting the shape of product |
| 848 | Endotracheal Tube, Cuff - Size 4.5mm• Soft cuff towards the distal end• Kink resistant inflation tube• Murphy eye at distal end with polished smoothness• Radio-opaque line• Standard 15 mm connector• Sterile, single use• Curved shaped blister pack – suiting the shape of product |
| 849 | Endotracheal Tube, Cuff - Size 5mm• Soft cuff towards the distal end• Kink resistant inflation tube• Murphy eye at distal end with polished smoothness• Radio-opaque line• Standard 15 mm connector• Sterile, single use• Curved shaped blister pack – suiting the shape of product |
| 850 | Endotracheal Tube, Cuff - Size 6mm• Soft cuff towards the distal end• Kink resistant inflation tube• Murphy eye at distal end with polished smoothness• Radio-opaque line• Standard 15 mm connector• Sterile, single use• Curved shaped blister pack – suiting the shape of product |
| 851 | Endotracheal Tube, Cuff - Size 6.5mm• Soft cuff towards the distal end• Kink resistant inflation tube• Murphy eye at distal end with polished smoothness• Radio-opaque line• Standard 15 mm connector• Sterile, single use• Curved shaped blister pack – suiting the shape of product |
| 852 | Endotracheal Tube, Cuff - Size 7mm• Soft cuff towards the distal end• Kink resistant inflation tube• Murphy eye at distal end with polished smoothness• Radio-opaque line• Standard 15 mm connector• Sterile, single use• Curved shaped blister pack – suiting the shape of product |
| 853 | Endotracheal Tube, Cuff - Size 7.5• Soft cuff towards the distal end• Kink resistant inflation tube• Murphy eye at distal end with polished smoothness• Radio-opaque line• Standard 15 mm connector• Sterile, single use• Curved shaped blister pack – suiting the shape of product |
| 854 | Endotracheal Tube, Cuff - Size 8• Soft cuff towards the distal end• Kink resistant inflation tube• Murphy eye at distal end with polished smoothness• Radio-opaque line• Standard 15 mm connector• Sterile, single use• Curved shaped blister pack – suiting the shape of product |
| 855 | Endotracheal Tube, Cuff - Size 8.5• Soft cuff towards the distal end• Kink resistant inflation tube• Murphy eye at distal end with polished smoothness• Radio-opaque line• Standard 15 mm connector• Sterile, single use• Curved shaped blister pack – suiting the shape of product |
| 856 | Endotracheal Tube, Cuff - Size 9• Soft cuff towards the distal end• Kink resistant inflation tube• Murphy eye at distal end with polished smoothness• Radio-opaque line• Standard 15 mm connector• Sterile, single use• Curved shaped blister pack – suiting the shape of product |
| 857 | Tracheostomy Tube (PVC), Plain, Sterile, Single Use - All Sizes• Soft flexible flange at for easy fixation• 15 mm connector at terminal end which can be rotated in 360 degree direction• Non-irritant• Radio-opaque line |
| 858 | Tracheostomy Tube (PVC), Cuffed, Sterile, Single Use - All Sizes• Soft flexible flange at for easy fixation• 15 mm connector at terminal end which can be rotated in 360 degree direction• Non-irritant• Radio-opaque line• Balloon with non return valve |
| 859 | Abdominal Drain Kit, Sterile, Having drainage catheter and Collection Bag (2000 ml) (size 24)• Graduated Bag• Should have well fitting cap• Soft drainage catheter 50 cm long, with radio opaque line• Rounded open distal end with smooth atraumatic eyes in catheter• Catheter with markings at 2 cm interval |
| 860 | Abdominal Drain Kit, Sterile, Having drainage catheter and Collection Bag (2000 ml) (size 28)• Graduated Bag• Should have well fitting cap• Soft drainage catheter 50 cm long, with radio opaque line• Rounded open distal end with smooth atraumatic eyes in catheter• Catheter with markings at 2 cm interval |
| 861 | Abdominal Drain Kit, Sterile, Having drainage catheter and Collection Bag (2000 ml) (size 32)• Graduated Bag• Should have well fitting cap• Soft drainage catheter 50 cm long, with radio opaque line• Rounded open distal end with smooth atraumatic eyes in catheter• Catheter with markings at 2 cm interval |
| 862 | Corrugated Drainage Sheet, Sterile, Multichannel, with radio opaque line, Single Use - All sizes |
| 863 | Polypropylene Nonabsorbable Synthetic Surgical Mesh 7.5 cmX 15 cm soft to feel fast edges,slightly stretchbonding. |
| 864 | Polypropylene Nonabsorbable Synthetic Surgical Mesh 15 cmX 15 cm soft to feel fast edges,slightly stretchbonding. |
| 865 | Sterilised Umbilical Cotton Tape Width 3 mm, Length 75 cmShould conform to Schedule F(III) of Drug and Cosmetic Act 1940 |
| 866 | Bone Wax Sterilised |
| 867 | Temporary Cardiac Pacing Wire (Electrode) Sterile ½ Cir, Tapercut, 26 mm; straight cutting 60 mm ,breakaway |
| 868 | Skin Graft Knife Blade (Sterile) (disposable )Skin Grafting Knife Blade (Sterile) made of carbon steel or stainless steel material 158 mm long individually wrapped in wrapper corrosion inhibitor paper in single packet,.In packs of 10. The edge must be sharp enough to cut the skin in a single shave and should snugly fit in the handle Should conform to IS 3759.2. Skin Grafting Knife Handle (Watson modification of Humby’s Knife ) Stainless Steel, CE certified, in which the blade specified in (a) above should fit snugly. Should conform to 7980-1976. |
| 869 | K Wire, length 375 mm; 1mm Length of wire should be mentioned with specification.Should conform to IS 8261 |
| 870 | K Wire, length 375 mm;1.6mm• Length of wire should be mentioned with specification.• Should conform to IS 8261 |
| 871 | K Wire, length 375 mm; size 1.8mm• Length of wire should be mentioned with specification.•Should conform to IS 8261 |
| 872 | Face Mask, Disposable• Should be manufactured from non woven poly prop fabric• Should be 3 ply construction• Should have high bacterial filtration efficiency• Should be heat sealed to keep 3 layers together• Standard size 17.5 x9 cm• Color green/blue• There should be a string each at all four corners,length of string should be 40cm• Nose clip should be there • No elastic band. |
| 873 | Surgical Cap, Disposable (For Surgeons)• Should be manufactured from non woven fabric.• Strip for tying the cap stitched on the back for proper grip on the forhead.• Green colour• Ultrasonically stitched• Air permeable/breathable• Should retain skin and hair particle.• Strip for tying the cap |
| 874 | Surgical Cap, Disposable ( For Nurses)• Should be manufactured from non woven fabric• Blue / Green colour• Round upon wearing, with elastic• Air permeable / breathable• Should retain skin and hair particles |
| 875 | Foldable Intra Ocular lense with injector (Size + 11 D to +17.5 D) Size:6mm optics. 12-13mm total diameter1. Made of foldable Acrylic (Hydrophobic) material 2. Bi-Convex single piece IOL with aspheric optics3. Size:6mm optics. 12-13mm total diameter.4. Modified C loop haptic/plate haptics (5. IOL should have UV blocking capability 6. IOL should have 360°square edge..7. foldable and insertion by injector with disposable cartridge insertable by a sub 2.8 mm incision size or smaller incision 8. Diopters- + 11 D to +17.5 D at 0.5 D step.9. Supplying unit should be ISO accredited and IOL should be CE/US FDA certified. |
| 876 | Foldable Intra Ocular lense with injector (Size + 18 D to + 24 D)Size:6mm optics. 12-13mm total diameter1. Made of foldable Acrylic (Hydrophobic) material 2. Bi-Convex single piece IOL with aspheric optics3. Size:6mm optics. 12-13mm total diameter.4. Modified C loop haptic/plate haptics5. IOL should have UV blocking capability 6. IOL should have 360°square edge..7. foldable and insertion by injector with disposable cartridge insertable by a sub 2.8 mm incision size or smaller incision8. Diopters- + 18 D to + 24 D at 0.5 D step.9. Supplying unit should be ISO accredited and IOL should be CE/US FDA certified. |
| 877 | Foldable Intra Ocular lense with injector (Size + 24.5 D to + 28.5 D ) Size:6mm optics. 12-13mm total diameter1. Made of foldable Acrylic (Hydrophobic) material 2. Bi-Convex single piece IOL with aspheric optics3. Size:6mm optics. 12-13mm total diameter.4. Modified C loop haptic/plate haptics 5. IOL should have UV blocking capability 6. IOL should have 360°square edge..7. foldable and insertion by injector with disposable cartridge insertable by a sub 2.8 mm incision size or smaller incision8. Diopters- + 24.5 D to + 28.5 D at 0.5 D step.9. Supplying unit should be ISO accredited and IOL should be CE/US FDA certified. |
| 878 | Standard PMMA Intra Ocular Lenses (Size + 11 D to +17.5 D)• 6mm optic size 12.5 - 13.0 mm total diameter, Biconvex1. PMMA optics and haptics single piece with hole2. 6mm optic size 12.5 to 13mm total diameter, Biconvex3. IOL haptics – modified C shaped with 5° -10° anterior angulation.4. Should have 360° square edges.5. IOL should have UV blocking capability6. Diopters- + 11 D to +17.5 D at 0.5 D step.7. Supplying unit should be ISO accredited and IOL should be CE/US FDA certified. |
| 879 | Standard PMMA Intra Ocular Lenses (Size + 18 D to + 24 D)• 6mm optic size 12.5 - 13.0 mm total diameter, Biconvex1. PMMA optics and haptics single piece with hole2. 6mm optic size 12.5 to 13mm total diameter, Biconvex3. IOL haptics – modified C shaped with 5° -10° anterior angulation.4. Should have 360° square edges.5. IOL should have UV blocking capability6. Diopters- + 18 D to + 24 D at 0.5 D step.7. Supplying unit should be ISO accredited and IOL should be CE/US FDA certified. |
| 880 | Standard PMMA Intra Ocular Lenses (Size + 24.5 D to + 28.5 D ) 6mm optic size 12.5 - 13.0 mm total diameter, Biconvex1. PMMA optics and haptics single piece with hole2. 6mm optic size 12.5 to 13mm total diameter, Bioconvex3. IOL haptics – modified C shaped with 5° -10° anterior angulation.4. Should have 360° square edges.5. IOL should have UV blocking capability6. Diopters- + 24.5 D to + 28.5 D at 0.5 D step.7. Supplying unit should be ISO accredited and IOL should be CE/US FDA certified. |
| 881 | Disposable Sterile Surgical Rubber Gloves Size 8 Inches• made of natural rubber latex powdered,without tear,properly folded in a paper• Should Conform to IS 13422• ISI marked/CE certified/FDA approved• Colour code marking to designate size |
| 882 | Disposable Sterile Surgical Rubber Gloves Size 8 Inches• made of natural rubber latex powder free,without tear,properly folded in a paper• Should Conform to IS 13422• ISI marked/CE certified/FDA approved• Colour code marking to designate size |
| 883 | Rubber examination gloves made of natural rubber latex. Non-sterile, Ambidextous, AQL 1.5 Micro Textured Powdered with absorbable dusting powder USP. Extra Small. should conform to IS 15354 |
| 884 | Rubber examination gloves made of natural rubber latex. Non-sterile, Ambidextous, AQL 1.5 Micro Textured Powdered with absorbable dusting powder USP. Small should conform to IS 15354 |
| 885 | Rubber examination gloves made of natural rubber latex. Non-sterile, Ambidextous, AQL 1.5 Micro Textured Powdered with absorbable dusting powder USP. Mediumshould conform to IS 15354 |
| 886 | Rubber examination gloves made of natural rubber latex. Non-sterile, Ambidextous, AQL 1.5 Micro Textured Powdered with absorbable dusting powder USP. Largeshould conform to IS 15354 |
| 887 | Pressure Monitoring Line / High Pressure Extension Line • Suitable for high pressure monitoring and for connection between syringe infusion pump and patient• Male luer lock at one end and female luer lock at other end ; should fit all standard equipment. Luer lock connectors should provide secure fitting.• Pressure upto 800 psi• Length 200 cm• Sterile |
| 888 | Urine Collecting Bag for new born /Paediatric Urine Collection Bag, capacity 100ml • Should have suitability for both male and female patients• Should be provided with adhesive for fixation and good grip with minimal risk of allergy and injury• Capacity 100 ml• Sterile |
| 889 | Umbilical Catheter (for New Born) All sizes• Radio opaque line• With female flexible mount• Colour coded connector• Open tip should be soft, rounded, atraumatic• Length 40 cm |
| 890 | Umbilical Cord Clamp• Suitable for clamping umbilical cord of new born • Security lock to prevent accidental opening after clamping• Grooved clamping area |
| 891 | Absorbable Oxidized Regenerated Cellulose net size 2”x 3” with surgical spongeTopical Absorbable HaemostaticBactericidal Property |
| 892 | Close wound Drainage Device under negative pressure (Closed Wound Suction Unit)• Option to use one or two catheters simultaneously• Bellow chamber with capacity 800 ml• Bellow unit with connector• Graduated Bellow• Connecting tube with clamp and “Y”connector• Curved needle / trocar with catheter• Multiperforated catheter / Radon drain with radio opaque line• Catheter 16 FG |
| 893 | Close wound Drainage Device under negative pressure (Closed Wound Suction Unit)• Option to use one or two catheters simultaneously• Bellow chamber with capacity 800 ml• Bellow unit with connector• Graduated Bellow• Connecting tube with clamp and “Y”connector• Curved needle / trocar with catheter• Multiperforated catheter / Radon drain with radio opaque line• Catheter 18 FG |
| 894 | T – Tube for Common Bile Duct Drainage• Kehr’s T Tube made from medical grade PVC, and siliconized• Smooth, kink resistant• Radio opaque line throughout the length• Sterile• Length 20 x 60 cm• Size 10 to 18 FG |
| 895 | Bone cement with antibiotics,fast and slow setting |
| 896 | General Specificaition for S-99 (a) and S- 99(b)Sanitary Napkins (for Menstrual Hygiene) Specifications:-• Sanitary Napkin consists of an outer covering provided with sufficient number of channels for leak protection and an absorbent filler material.• The Sanitary Napkins shall have a soft feel and when worn shall not chafe or give any uncomfortable feeling. Should be odourless. • The material used in fabrication shall be non allergenic.• Shall be free from acids and alkali.• Each primary package shall contain 6 napkins in a polyethylene bag of good quality which should conform to size of product and sealed properly.• Both upper and lower sheets shall be white in colour. • Shall conform to IS 5405. • Type of material and size should be mentioned as per IS 5405• Instruction for usage should be mentioned on every packet. |
| 897 | Sanitary Napkin, Beltless 1. Covering – Covering of the absorbent filler shall be good quality knitted sleeve or non-woven fabric which has sufficient porosity to permit the assembled napkin to meet the absorbency requirements. The napkins shall have a non absorbent barrier on one side which shall have an identifying mark indicating the side of the barrier.2. Absorbent Filler – The filler material shall consist of cellulose pulp/ wadding, and shall be free from lumps, oil spots, dirt or foreign material, etc.3. Back Strip – A back strip for sticking the sanitary napkin onto the underwear should be there using good quality adhesive material.4. Size - The size of absorbent section / complete sanitary napkin shall be as follows: ( in mm)Absorbent section TotalPad Length 210 +_ 10 230 +_ 10Width 60 to 75 70 to 85Thickness 8 +_ 25. Weight : Not more than 10 gm . . Instruction for usage should be mentioned on every packet |
| 898 | Sanitary Napkin, Belttype1. Covering – Covering of the absorbent filler shall be good quality knitted sleeve or non-woven fabric which has sufficient porosity to permit the assembled napkin to meet the absorbency requirements. The napkins shall have a non absorbent barrier on one side which shall have an identifying mark indicating the side of the barrier.2. Absorbent Filler – The filler material shall consist of cellulose pulp/ wadding, and shall be free from lumps, oil spots, dirt or foreign material, etc3. Size - The size of absorbent section / complete sanitary napkin shall be as follows: ( in mm)Absorbent sectionPad Length 220 +_ 10Width 70 +_ 5Thickness 17 +_ 34. Weight : 12 +_ 3 gm5. Pack – Six napkins in a pack.6. Elastic Belt with loops shall be provided in each pack.7. Absorbency: The napkin should be able to absorb not less than 30 ml of normal saline or coloured water or test fluid when poured on to the centre of the napkin at the rate of 15 ml per minute. .Instruction for usage should be mentioned on every packet. |
| 899 | Belt-less Sanitary Napkin with wings1. Covering (Absorbing top sheet corrector)–Good Quality knitted sleeve or non woven fabric of rash free,non irritant and soft to touch material which has sufficient porosity to permit the assembled napkin to meet absorbency requirements.The napkins shall have a non absorbent barrier on one side with adhesive covered by a differently identifiable paper2.Overall Length (mm) 230 ± 53.Core length 220 mm± 104.Fluff core/pad length 220 mm± 105. Over all width with wings 160mm+_56.Fluff core/pad length 70 mm± 57.Thickness of a single pad 9-10mm8. Weight of a single pad : 8-10 gm9. Pack Six napkins in a pack.10 Type.- Belt-less Sanitary Napkin with wings11. Minimum Absorbency: 50ml12. pH value of absorbent material 6-8.5 B. DISPOSABLE Individual pouch or wrapper for each sanitary napkin(as per ministry of environment,forest and climate change dated 08.04.2016) Pouch/Wrapper Specifications :-1. Pouch/Wrapper should be of the size of sanitary napkin being supplied.2. It should have adhesive to seal the sanitary napkins within.3. Pouch/Wrapper should not be transparent.Note : Instructions for use of disposable pouch/wrapper mst be written in Hindi on disposable pouch/wrapper.bLrseky fd;s gq;s lsusVjh uSifdu dks eksM dj Disposable Pouch/Wrapper esa Mkys ,oa Disposable Pouch/Wrapper dks xksan yxh iV~Vh ls cUn dj lqjf{kr rjhds ls dwMsnku esa MkysaA |
| 900 | Oxygen mask (Adult) • Mould Facemask with adjustable elastic strap for proper position of mask on the mouth and nasal area• Friendly soft medical PVC material with comfortable fitting.• Aluminium nasal clip provides better fixation.• Anatomical design provides lighter seal.• Latex free elastic strap available. |
| 901 | Oxygen mask (Paediatric)• Mould Facemask with adjustable elastic strap for proper position of mask on the mouth and nasal area• Friendly soft medical PVC material with comfortable fitting.• Aluminium nasal clip provides better fixation.• Anatomical design provides lighter seal.• Latex free elastic strap available.• Mask connector 4M |
| 902 | Sterile Catheter, single Use, for Urinary Drainage(Foley Baloon Catheter), 2 way, Size 14• Made of Silicone elastomer bonded with Latex• Should have hard plastic valve• Smooth distal end with smooth eyes for a traumatic intubation• Symmetrical Foley Balloon• Balloon Capacity 30+- 1 ml• Should conform to IS 11497• Color coding marking to identify size• Length, wall thickness and ballon capacity should be mentioned as per IS 11497• Specification for B,C,D,E,F,G should be mentioned as per IS 11497 |
| 903 | Nelaton - Catheter size 14 FGDistal end is close and proximal end has female colour code connector• Soft, Kink resistant medical grade PVC tube • Length:40 cm• Individually packed in poly and sterile |
| 904 | ECG Electrode •Reliable trace, •High conductivity,• Easy to handle |
| 905 | Surgical Blade Sterile, Size 23• Single peel pack in metal foil• The tip of the blade shall be well defined, central and sharp. There shall be no waviness, jags, feathers, nicks, or other defects on the cutting edge. The surfaces of the blade shall be smooth and free from tool marks and any sign of corrosion.• Should conform to IS 3319 |
| 906 | Sterile Hypodermic Syringe with Needle attached, 22G, Single Use - 50 ml• Clear transparent chamber• Prominent graduation• Inert material gasket at the piston to minimise friction during movement & prevent leakage and back flow• Sharp needle ensuring minimum trauma during penetration• Shall conform to IS 12050• Packing: Needle should be attached with the syringe and packed in unit ribbon pack• The words \\"DESTROY AFTER SINGLE USE\\" or equivalent should be written on Unit Container. |
| 907 | Urethral Catheter 90 (FG-14), made up of medical grade PVC |
| 908 | Urethral Catheter 91 (FG-10), made up of medical grade PVC |
| 909 | Vaccum Suction Set, 2.5 meter Length, •Suction handle with Suction Tube•Sterile,• Pyrogenic Free, •Latex free,• Single use |
| 910 | Epidural Minipack 18G, 90 mm, Metal Stylet For Single Use only, •Sterile, •Epidural catheter 20G, L 90 cm,•6 Lateral Holes closed end, •Borst Adapter•Epidural Catheter Flat filter 0.2 micro meter •Thread Assist Guide•LOR (Loss of resistance) Plastic Syringe 6 ml |
| 911 | Vascular Catheter with metal Guide No. 16, Double Lumen Size 30 cm (Longline IV.) |
| 912 | Vascular Catheter with metal Guide No. 18 Double Lumen Size 30 cm (Longline IV.) |
| 913 | Vascular Catheter with metal Guide No. 20 Double Lumen Size 30 cm (Longline IV.) |
| 914 | Vascular Catheter with metal Guide No. 22 Double Lumen Size 30 cm (Longline IV.) |
| 915 | Vascular Catheter with metal Guide No. 16 Double Lumen Size 45 cm (Longline IV.) |
| 916 | Vascular Catheter with metal Guide No. 18 Double Lumen Size 45 cm (Longline IV.) |
| 917 | Vascular Catheter with metal Guide No. 20 Double Lumen Size 45 cm (Longline IV.) |
| 918 | Vascular Catheter with metal Guide No. 22 Double Lumen Size 45 cm (Longline IV.) |
| 919 | 3 Way Stop Cock , Non Pyrogenic & Single Use, should be leak proof, with smooth movements |
| 920 | 3 Way Stop Cock with extension Tube (Vein -O-Line) size 10 cm (Non Pyrogenic & Single Use) |
| 921 | 3 Way Stop Cock with extension Tube (Vein -O-Line) size 50 cm (Non Pyrogenic & Single Use) |
| 922 | 3 Way Stop Cock with extension Tube (Vein -O-Line) size 100 cm (Non Pyrogenic & Single Use) |
| 923 | 3 Way Stop Cock with extension Tube (Vein -O-Line) size 150 cm (Non Pyrogenic & Single Use) |
| 924 | Abdominal Drain Kit, Sterile, having drainage catheter and Collection Bag (2000 ml) (size 16)• Graduated Bag,• Should have well fitting cap• Soft drainage catheter 50 cm long, with radio opaque line• Rounded open distal end with smooth atraumatic eyes in catheter• Catheter with markings at 2 cm interval |
| 925 | Abdominal Drain Kit, Sterile, having drainage catheter and Collection Bag (2000 ml) (size 20)• Graduated Bag• Should have well fitting cap• Soft drainage catheter 50 cm long, with radio opaque line• Rounded open distal end with smooth atraumatic eyes in catheter• Catheter with markings at 2 cm interval |
| 926 | Nasal Pronge Neonatal (Flexible Medical Grade, 2 Meter Long, Multichannel Kink Resistance Tube |
| 927 | Elastic Adhesive Bandage BP 1m x 10cmAdhesive material should have good quality sticking property, non-allergic |
| 928 | Sterile Disposable (Single Use Teflon/PTFE I.V Cannula with integrated 3 way stop cock Size 26G• Should be packed in transparent single blister pack• Should confirm to IS 10555 standard• (Neonatal IV Cannula Size 26) |
| 929 | NIV Mask (Noninvasive Ventilation Mask) Adult• Should be light weight silicon based full face & nasal mask with face &forehead soft cushion pads for adults in Large size.• Should be with ergonomically designed clips/straps for easy disengagement of the head gear. • Should be Single Use for Ventilator without vent • Non allergic, leak proof, contour should be maintained |
| 930 | NIV Mask (Noninvasive Ventilation Mask) Adult• Should be light weight silicon based full face & nasal mask with face &forehead soft cushion pads for adults in Medium size.• Should be with ergonomically designed clips/straps for easy disengagement of the head gear. • Should be Single Use for Ventilator without vent • Non allergic, leak proof, contour should be maintained |
| 931 | NIV Mask (Noninvasive Ventilation Mask) Adult• Should be light weight silicon based full face & nasal mask with face &forehead soft cushion pads for adults in Large size.• Should be with ergonomically designed clips/straps for easy disengagement of the head gear. • Should be Single Use for BiPAP with vent• Non allergic, leak proof, contour should be maintained |
| 932 | NIV Mask (Noninvasive Ventilation Mask) Adult• Should be light weight silicon based full face & nasal mask with face &forehead soft cushion pads for adults in Medium size.• Should be with ergonomically designed clips/straps for easy disengagement of the head gear. • Should be Single Use for BiPAP with vent• Non allergic, leak proof, contour should be maintained |
| 933 | NIV Mask (Noninvasive Ventilation Mask) Paediatric• Should be light weight silicon based full face & nasal mask with face &forehead soft cushion pads in Small size. • Should be with ergonomically designed clips/straps for easy disengagement of the head gear• Should be Single Use with Bronchoscopy and CO2 &O2 port with chin support • Non allergic, leak proof, contour should be maintained |
| 934 | Nebulization Mask Adult |
| 935 | Nebulization Mask Paediatric |
| 936 | Chemotherapy Port &Non-coring needles(Adult)• Valved catheter need only saline flush, catheter with intermediate size port with small septum and silicon filled suture holes, should be MRI compatible with cathlock radio-opaque ring. 8FR with silicon material with peel apart percutaneous introducer system.• Chemo port huber needle 20g and 22g. |
| 937 | Chemotherapy Port &Non-coring needles(Pediatric)• Valved catheter need only saline flush, catheter with intermediate size power port with large septum and silicon filled suture holes, should be MRI compatible with cathlock radio-opaque ring. 6FR with silicon material with peel apart percutaneous introducer system• .Chemo port huber needle 20g and 22g. |
| 938 | Core biopsy instrument with compatible co-axial needle (Automatic disposal ) |
| 939 | Disposable bone marrow biopsy needle |
| 940 | Eyelid occlusion dressing |
| 941 | Eye pressure shield |
| 942 | Rebreathing Beg 2 Lit. |
| 943 | Shoe Cover |
| 944 | Infant Feeding Tube Size -6 |
| 945 | Gelaspan 4% (Gleatin PVC Free bottle) |
| 946 | Poly(lactide-co-glycolide) Powered Absorabale Fixation device with counter display on firing handle |
| 947 | Securement Device with adhesive in the middle to secure catheters & tubings. Waterproof, hypoallergenic & non-stretchable to retain the shape size: Small (lines & Tubes sized 1.5-4.5 mm) |
| 948 | Securement Device with adhesive in the middle to secure catheters & tubings. Waterproof, hypoallergenic & non-stretchable to retain the shape size: Medium (lines &Tubes sized 3-8 mm) |
| 949 | ECG Lead guided catheter for critically ill patents.Triple lumen Central Venous Catheter 5F (20/22/22) 8D made ofCerton, a special grade polyurethane, length 8cmvalve needle having side port, Novlon material dilator, scalpel,NitinolGuidewire, safesite connector and ECG lead. |
| 950 | Sequential electrical nerve stimulator with SENSE technology |
| 951 | Securement Device with adhesive in the middle to secure catheters & tubing. Waterproof, hypoallergenic & non-stretchable to retain the shape size: Large (lines & Tubes sized 6-13 mm) |
| 952 | Pencil Point spinal needle size 25 G / 27 G Shorter tip-to-back of eyelet distance (1.7mm). Shorter tip-to-front of eyelet distance (1.05mm). Eyelet is size 0.65mm |
| 953 | Securement Device with adhesive in the middle to secure catheters & tubing. Waterproof, hypoallergenic & non-stretchable to retain the shape size: JUGULAR |
| 954 | Securement Device with adhesive in the middle to secure catheters & tubings. Waterproof, hypoallergenic & non-stretchable to retain the shape size: X-Large (lines & Tubes sized 6-15 mm) |
| 955 | Titanium Powered Non Absorabable Fixation device with counter display on firing handle |
| 956 | Regional Anaesthesia Single shot nerve blocks under HNS12 machine.. 30’ Bevel cut stiumplex ultra needle with 360 degree X markings visible & performed under ultrasound in sizes 35mm/50mm/100mm/150mm. |
| 957 | Latex free disposable pencil point spinal needle 27G , 127.5 mm with grooved transparent hub with centering protective plastic sleeve, Touhy needle with black eye - 18 G (1.3 x 88 mm). Protrusion of spinal needle through the back eye of the epidural needle. With epidural catheter, filter, loss of resistance syringe and separate locking device - Docking System. |
| 958 | Disposable Needle Size - 18 |
| 959 | Disposable Needle Size - 20 |
| 960 | Disposable Needle Size - 22 |
| 961 | Disposable Needle Size - 23 |
| 962 | Disposable Needle Size - 24 |
| 963 | Disposable Needle Size - 26 |
| 964 | EU CE marked,EN13795,TUV approved with certified test for, Resistance to Microbial Penetration test Back Table Cover-150 X 190,4 Towels-30 X 40,Instrument Placement- Mayo Stand 80 x 145,Adhesive Strip-9x50, swaddle cloth, fluid-absorbent nonwoven material 90 x 90,Opaque Layer, for the supine position, 230/200 x 312, with abdominal fenestration, 27 x 33 |
| 965 | EU CE marked, EN13795,TUV approved with certified test for, Resistance to Microbial Penetration test swaddle cloth with fluid absorbent nonwoven material Size 90x100 cm |
| 966 | Special SMMS , CE,ISO,TUV,EN13795 approveded, Spunless closer types with cuff |
| 967 | Surgical Knife-Cresent |
| 968 | Surgical Knife-Keratome |
| 969 | Surgical Knife-MVR |
| 970 | EU CE marked,EN13795,TUV approved with certified test for, Resistance to Microbial Penetration test Back Table Palcement-150 X 190,Towels-30 X 20,Instrument Palcement- Mayo Stand 80 x 145,Adhesive Strip-9 X 25,Adhesive Cloak-75 x 90,Adhesive Cloak- Bottom-175 x 170,Adhesive Cloak- Top-140 x 240 |
| 971 | Single Use Negative Pressure Wound Therapy System (sNPWT) 14days consists of a pioneering, silicone AIRLOCK™ Technology battery- operated deviceCreate Negative Pressure-80mm/hg,Low battery Indicator,On/pause therapy button,Pump is functioning properly Indicator,Air leak detected Indicator,Tubing connector,Dressing full Indicator,Therapystart date label,Sliding battery cover,Moulded belt pump clip (provided with the 14 system) – Transparent to enable visibility of pump labelling. (S, M, L) |
| 972 | Drain Tube & chest tube holder with silicon fixing plate & lock sets. High absorption around the drainage catheter, prevents the infection caused by the accumulation of seepage. |
| 973 | ET Tube Holder with flexible channel having adjustable clamp & dual locking system for holding the ET tube sizes between 7.0-10.0 I.D. |
| 974 | Limb Holder immobilizer with 150cm long strap with an integrated grip for attaching. |
| 975 | Multifunctional mask- it should have provision of attaching Nebulizing chamber, access for hydration, oral suction without interrupting oxygen therapy, special opening on sides to accommodate NG and OG tubes. It should be designed to administer high oxygen. FDA approved. It should have adapter, tubing & nebulizer. |
| 976 | IV bag & Bottle spike with hydrophobic & antibacterial filter to prevent contamination of solutions. |
| 977 | Dressing pad for single use Negative Pressure Wound Therapy 14days consists of a pioneering, silicone AIRLOCK™ Technology (S,M,L) |
| 978 | Porous collagen from fish source with Mupirocin and Metronidazole in particle form, size-10ml |
| 979 | Endotracheal Tube Plain Size - 2 |
| 980 | Laryngeal Mask Airway All Size |
| 981 | a single-use haemofilterdesigned to remove and/or control water, electrolytesand toxins in the blood by continuous extracorporealcirculation i.e renal replacement therapy, filled with hollow fibers made of polymethyl methacrylate(PMMA), capable of adsorbing excess cytokines by filtration & adsorption |
| 982 | Electrolysed Non-Toxic, Non-Irritant and Non-Corrosive, Ready to use Disinfectant Solution with Neutral pH containing Sodium Chloride (Na Cl)- )0.023%, Sodium Hypochlorite (NaOCl)- 0.005%, Hypo Chlorous Acid (HOCl)- 0.004%, Electrolysed Water- 99.97% in Jerricane of 5 Litre |
| 983 | Cannuala Fixer |
| 984 | Intercostal Drainage Tube with Trochar |
| 985 | Super Oxidized solution with Neutral ph containing Hypochlorous acid (0.003%) and Sodium Hypochlorite (0.004%) for wound treatment in Spray Bottle of 500ml |
| 986 | Super Oxidized solution with Neutral ph containing Hypochlorous acid (0.008%) and Sodium hypochlorite (0.002%) for wound dressing in Pump Bottle of 120gm |
| 987 | Bare Fiber shall be OEM compatible with the MESIC 1470 nm Class IV Diode Laser System and shall be designed for precise cutting, coagulation, and tissue ablation applications. The fiber shall be supplied with SMA 905 connector compatibility and shall support core diameters from 320 µm to 600 µm with suitable numerical aperture for efficient laser energy transmission. |
| 988 | Intercostal Drainage Bag |
| 989 | Baby I.D. Bands (Tag) |
| 990 | Pure Poly Siloxane based silicone scar management product in Gel form(100% Poly siloxane)-10gms |
| 991 | Radial Fiber shall be specifically designed for circumferential laser energy emission compatible with MESIC 1470 nm diode laser systems. The fiber shall provide uniform 360-degree radial energy distribution for minimally invasive therapeutic procedures and shall be supplied with OEM-compatible SMA 905 connector configuration. |
| 992 | Medical Body Protector premium |
| 993 | Class 1 EC Medical Device with Accuracy and waterproof adhesive thermochromic temperature indicator with three colour code |
| 994 | IV Cap Disinfectant cap having passive disinfection to protect hubs /ports by acting as a physical barrier to contamination between accesses. |
| 995 | Secura Tracheostomy tube holder neckband with absorbent foam . |
| 996 | Pure link Double needle free connectors fixed to bifurcated macrobore extension set with luer lock & slide clamps. |
| 997 | Nano Cap for Ports prevention. |
| 998 | Conical Fiber shall be OEM compatible with the MESIC 1470 nm Class IV Diode Laser System and shall be designed to provide focused conical laser beam delivery for enhanced cutting and coagulation performance. The fiber shall support high-efficiency laser transmission with optimized distal tip geometry suitable for surgical applications. |
| 999 | Extremity Set ( Knee Replacement Kit ) mention below specs,EU CE marked,EN13795,TUV approved with certified test for, Resistance to Microbial Penetration test (Dry & Wet),Resistance to liquid penetration test, Cleanliness test. (Microbial & Particulate matter),Bursting strength ( Dry & Wet),Tensile strength test ( Dry & Wet),Linting test. Back Table Cover-150 X 190,Towels-30 X 20,Adhesive Strip-9 X 25,Instrument Table Cover- Mayo Stand-80 x 145,OT Drape Sheet-150x150Stockinette-33x55,Adhesive Film Strips-10x50,Extremity Drape-200x300 |
| 1000 | Non alcoholic barrier spray 360' fumes |
| 1001 | Horizontal Drain/Tube Attachment Device Skin Barrier With Elastaflex Backing,Size.5-40 FG |
| 1002 | Pur-Xro 28G/1fr PICC catheter 20cm length with stylet, spliting introducer needle,securing wings, measuring tape and every cm marking , flow rate 0.7ml/min with 8 cm extension tubing and clamp |
| 1003 | Radiopaqe wit EXPERT Technology, Contaning AgION™ antimicrobial agent CATHETER 40CM WITH 3.5, 4,5,8 FR COMPATIBLE FOR BOTH ARTERIAL AND VENUS ROUTE WITH FEMALE LUERLOCK SUPPLIED WITH STOPCOCK AND COLOUR CODED CLIP |
| 1004 | Pur-xro 22G catheter with stight guidwire and introducer with integral extension and clamp . Length 4,6,8,10,20cm |
| 1005 | PE BABY WRAP DOUBLE LAYER GREEN HOUSE HAS BED WITH ADJUSTABLE HUD, FRONT VELCO AND SPINE SUPPORT FOR PRE TERM BABY TO AVOIDE HYPOTHERMIA SIZE SMALL,MEDIUM,LARGE |
| 1006 | LISA CATHETER 6FR 20CM WITH 2CM BLACK BLUNT ANGLED SOFT DISTAL TIP. BENDABLE MATERIAL, CENTIMETRIC MARKING, LOW DEAD SPACE 0.2ML. |
| 1007 | V-Tad,Vertical Tube Attachmemt Device Skin Barrier With Elastaflex Backing.Size.5 – 40 FG |
| 1008 | F – Tad, feeding tube attachment device, Unique clamping Mechanism & attached Skin barrier for NG tube, size.5-18 FG. |
| 1009 | locked pur Antireflex valve with Silicon duff 10 cm 2 lumen and 3 luman extension tube with colour coated clip |
| 1010 | Pur 7.5fr triple tumen(14/18/18) catheter 12.5cm with BLS valve and natinol guidewire |
| 1011 | Double needle free connectore fixed to bifurcated minibore extension set with luer lock & slide clamps. |
| 1012 | Polyethylene arterial catheter 20 G length 8 cm seldinger technique with antikinking collar comes with puncture needle 20 G |
| 1013 | Endoscopic Linear Cutter Disposable endoscopic stapler with universal handle and 160 mm shaft, allowing up to 12 firings per handle. Compatible with 45 mm and 60 mm cartridges, each featuring 6 rows of B-shaped staples for superior staple line security. Proximally controlled 45° articulation, 360° rotation knob, and wide jaw opening ensure precise tissue placement with Ridges and improved perfusion. Equipped with new knife blade per firing, stepped compression to reduce tissue trauma, safety interlock to prevent misfiring, consistent stapling technology, slimmer and stronger anvil, blade position indicator, and loop handle for easy gripping and firing. Packing: 1 piece per box. With 6 Assorted reloads of Open staple height: 2.0–3.0 mm, closed staple height: 0.75–1.25 mm / Open staple height: 3.0–4.0 mm, closed staple height: 1.25–1.75 mm / Open staple height: 4.0–5.0 mm, closed staple height: 1.75–2.25 mm.\\" Minimum last 3 years MSC is mandatory. |
| 1014 | S/M/L size garments for vest airway machine |
| 1015 | Convex synthetic skin barrier withfloating flange centre point locking system. Size.70 mm. Can be cut up to 13-51 mm |
| 1016 | soft easy to Squeeze Tube for filling the uneven peristomal area, low in alcohol to minimize stinging ,improve the fit of skin barrier (60 gm) |
| 1017 | stoma Powder , 28 gm. Is use to absorb extra moisture from Broken peristomal area which allows for better barrier adhesion& help to reduce itchiness and excoriation. after applying skin barrier. |
| 1018 | Skin gel wipes .Helps Prevent Irritation associated with removal of Adhesives. Acts as a Protective Interface between Skin and Bodily wastes and fluids when used with Adhesive Products. In Sachet Form ALCHOHAL FREE |
| 1019 | Colostomy Skin conditioning cream,Soothes irritated dry skin,improving tolerance .To repeated tape and barrier use. contains Aloe Vit.A,D & E. 118 ml. (bottle) |
| 1020 | Ostomy WDC for wound upto 10 X 20 cm with odour barrier film, , excess cap Synthetic Skin Barrier |
| 1021 | Resorbable Collagen based Sealing Hemostat- Material of Construction: Bovine Collagen patch, NHS-PEG (N-Hydroxysuccinimide polyethylene glycol) and Brilliant Blue FCF Dimension: 45mm * 90 mm |
| 1022 | Resorbable Collagen based Sealing Hemostat- Material of Construction: Bovine Collagen patch, NHS-PEG (N-Hydroxysuccinimide polyethylene glycol) and Brilliant Blue FCF Dimension: 45mm * 45 mm |
| 1023 | Incare Inview (CV SHEATH) Silicone ,Self adhesive.size. 25/29/32/36 mm. |
| 1024 | Disposable Monopolar Pencil with Tip Cleaner |
| 1025 | Hemostatic matrix with thrombin 5 ml . Pre-filled syringe of Bovine-derived Spherical Gelatin granule matrix along with a vial of human-derived Thrombin component (500IU/ml) & 0.9% Sodium Chloride Solution for needle-free reconstitution. 5ml Syringe applicator tips are included to facilitate the delivery of Product. |
| 1026 | Non- lead Radiationprotection gloves – BIS Certified |
| 1027 | Drainable pouch with skin barrier with integrated lock ‘n rollmicroseal closure & has AF 300 filter to reduce the odour and balooning. cutting area upto 55 mm |
| 1028 | Drainable pouch with skin barrier with integrated lock ‘n rollmicroseal closure & has AF 300 filter to reduce the odour and balooning. cutting area upto 65 mm |
| 1029 | Drainable pouch with integral convexity skin barrier with integrated microseal closure has AF 300 filter to reduce the balooning. cutting area up to 51 mm |
| 1030 | Triple chambered Nutrition(3 in one) for Periperal IV Emlusions 1000ml-1200ml with 80% Olive /20% Soya Lipid,Amino acids,glucose & Electrolytes. TPN 1Ltr Triple chamber bag should contain Protein 20-45 gm/L Lipid 20-40gm/L Glucose 80-160 gm/L |
| 1031 | Triple chambered Nutrition(3 in one) for Periperal IV Emlusions 1800ml-2100ml with 80% Olive /20% Soya Lipid,Amino acids,glucose & Electrolytes. TPN 1Ltr Triple chamber bag should contain Protein 20-45 gm/L Lipid 20-40gm/L Glucose 80-160 gm/L |
| 1032 | Synthetic Absorbable Knotless Barbed Surgical Suture made of PGA-PCL (Poly Glycolic Acid–Polycaprolactone), Violet coloured, Unidirectional barbed, Size 2-0, 15 cm length, with 1/2 Circle Round Body needle, 27 mm, sterile. The suture and its needle should be indigenous in nature and backed up with valid supporting certification/documentary evidence from the manufacturer. |
| 1033 | Curos caps for needleless connectors Alcohol-containing caps that twist onto needleless connectors in IV ports for disinfection and protection. Each cap contains 70% isopropyl alcohol (IPA) which bathes the surface of the port and disinfects it in 1 minute and protects ports for up to 7 days if not removed. It should be 10 caps per strip. |
| 1034 | Polyhexamethylene biguanide hydrochloride, alkyl dimethyl benzylammonium chloride, didecyl dimethyl ammonium chloride |
| 1035 | Multicomponent compression system with Pressure Spot indicator circle, composed of a short stretch & long stretch bandage made of viscose, polyester, polyamide and elastane. Size: 18- 25 cm (Length) , 10 cm (width), European CE Approved |
| 1036 | G Dress 10.5*25cm |
| 1037 | G Dress 8.5*6.5cm |
| 1038 | Healing matrix with Technology lipidocolloid with AgSO4- having Carboxymethyl cellulose and fat particles, 4-digit European CE Certified, Size-15x20cm |
| 1039 | Healing matrix with Technology lipidocolloid with AgSO4- having Carboxymethyl cellulose and fat particles, 4-digit European CE Certified, Size-10x12cm |
| 1040 | Advaced Fluid Aministration System with Air Stop and Prime Stop with itegrated Back Check Valve Bacterial retention Air vent, transparent spike designed in accordance with ISO 8536-4, Transparent Drip Chamber (Double),15 micron Fluid Filter in the chamber,Medical Grade, DEHP free transparent kink free tubing. USFDA/CE approved |
| 1041 | The sterile native collagen sheet (ECM-based) shall be biocompatible as per ISO 10993, non‑toxic, non‑allergenic, and non‑immunogenic. It shall comply with risk‑management requirements in EN ISO 14971:2012 and EN ISO 22442:2007,and meet the standards of ISO 22442 (Parts 1–3) to ensure proper sourcing, collection, and handling, as well as validation of the elimination or inactivation of viruses. The material shall be free from viral and other transmissible microorganisms. The product shall use non‑denatured, wet, bovine collagen with consistent thickness and elasticity |
| 1042 | Fully automatic non ported closed IV Catheter with Passive safety shield located inside the HUB before activation deploys automatically, cannot be bypassed and requires no user activation, Catheter material FEP/Certon, four embedded Radio-opaque contrast lines, Universal Back cut bevel, multi-access blood control septum to prevent blood exposure, hydrophobic membrane with transparent flashback chamber and double flashback mechanism, Integrated Stabilization Platform, Power Injectable – Pressure rated for contrast media application at 300 psi (18G ) USFDA/CE approved |
| 1043 | Fully automatic non ported closed IV Catheter with Passive safety shield located inside the HUB before activation deploys automatically, cannot be bypassed and requires no user activation, Catheter material FEP/Certon, four embedded Radio-opaque contrast lines, Universal Back cut bevel, multi-access blood control septum to prevent blood exposure, hydrophobic membrane with transparent flashback chamber and double flashback mechanism, Integrated Stabilization Platform, Power Injectable – Pressure rated for contrast media application at 300 psi 20G USFDA/CE approved |
| 1044 | Fully automatic non ported closed IV Catheter with Passive safety shield located inside the HUB before activation deploys automatically, cannot be bypassed and requires no user activation, Catheter material FEP/Certon, four embedded Radio-opaque contrast lines, Universal Back cut bevel, multi-access blood control septum to prevent blood exposure, hydrophobic membrane with transparent flashback chamber and double flashback mechanism, Integrated Stabilization Platform, Power Injectable – Pressure rated for contrast media application at 300 psi (22G) USFDA/CE approved |
| 1045 | Synthetic Absorbable Knotless Barbed Surgical Suture made of Polydioxanone (PDO), Violet coloured, Unidirectional barbed, Size 1-0, 15 cm length, with 1/2 Circle Round Body needle, 37 mm, sterile. The suture and its needle should be indigenous in nature and backed up with valid supporting certification/documentary evidence from the manufacturer. |
| 1046 | Synthetic Absorbable Knotless Barbed Surgical Suture made of Polydioxanone (PDO), Violet coloured, Unidirectional barbed, Size 1-0, 30 cm length, with 1/2 Circle Round Body needle, 37 mm, sterile. The suture and its needle should be indigenous in nature and backed up with valid supporting certification/documentary evidence from the manufacturer. |
| 1047 | The sterile native collagen sheet (ECM-based) shall be biocompatible as per ISO 10993, non‑toxic, non‑allergenic, and non‑immunogenic. It shall comply with risk‑management requirements in EN ISO 14971:2012 and EN ISO 22442:2007,and meet the standards of ISO 22442 (Parts 1–3) to ensure proper sourcing, collection, and handling, as well as validation of the elimination or inactivation of viruses. The material shall be free from viral and other transmissible microorganisms. The product shall use non‑denatured, Dry, bovine collagen with consistent thickness and elasticity. Size-15x30cm |
| 1048 | Synthetic Absorbable Knotless Barbed Surgical Suture made of Polydioxanone (PDO), Violet coloured, Unidirectional barbed, Size 2-0, 25 cm length, with 1/2 Circle Round Body needle, 27 mm, sterile. The suture and its needle should be indigenous in nature and backed up with valid supporting certification/documentary evidence from the manufacturer. |
| 1049 | EU CE marked,EN13795,TUV approved with certified test for, Resistance to Microbial Penetration test Size 75x 120 cm,Non-woven Under Skirt and Layer With high-absorbency, fluid-impermeable nonwoven material with polyethylene backing, featuring ultrasonic-sealed edges for leak prevention surgical drape standards for single-use . |
| 1050 | EU CE marked,EN13795,TUV approved with certified test for, Resistance to Microbial Penetration test Back Table Cover-150 X 190,Towels-30 X 40,Instrument Table Cover- Mayo Stand 80 x 145,Adhesive Strip-50X50,Swathe with Fenestration,with integrated fluid collection pouch, with lateral gutters incl. sieve and drainage port,with integrated tube fixations |
| 1051 | Double lumen Central Venous Catheter 7F (16G/16 G), made of Certon, a special grade polyurethane, length 15/20 cm, 18 G valve needle having side port, Novlon material dilator, scalpel, Nitinol Guidewire, safesite connector and ECG lead USFDA/CE approved |
| 1052 | Amorphous Hydrogel in Applipak composing of 2.3% Carboxymethylcellulose,20.0% Propylene Glycol & Purified water, promotes rapid but gentle debridement of necrotic tissue. size 25gm |
| 1053 | Adhesive porous wound dressing heel shaped change indicator technology with pad 20 - 25 x 20 - 25 Cm |
| 1054 | Disposable handpiece to be used with Hydrosurgery Based Debidement unit for quick and precision based debridement in a non OT environment Size of 45⁰ and 14mm and 15⁰ 14mm |
| 1055 | Transparent, visual observation ofthe surgical site, highly extensible 0.03mm thick permeable to gas and moisture vapour, prevents fluid build-up and dressing lift high quality initial pressure sensitive tack maintain dressing position on patients' skin,reduce the occurrence of skin sensitization. provides sustained adhesion during long, manipulative procedures. Sizes : 45x55cm |
| 1056 | Triple lumen Central Venous Catheter 7F (16G/18G/18 G), made of Certon, a special grade polyurethane, length 15/20 cm, 18 G valve needle having side port, Novlon material dilator, scalpel,Nitinol Guidewire, safesite connector and ECG lead USFDA/CE approved |
| 1057 | Disposable Curved Circular Stapler 29/ 31 mm with Three Circular Staggeted Staple Lines (3 Rows) and Optimized Staple Formation Techinque, Tissue Compression Indicator, Open Staple leg Length of 4.5 mm which can accommodates compressed tissue thickness from 1.0- 2.5 mm |
| 1058 | Disposable Linear Cutter Stapler with Dual Side Firing feature, Anti slip body, Rear Hinge locking for intermediate position, Push Button for quick opening and interchangeable Blue & Green Reloads |
| 1059 | Dispsable Blue Repoad/ Green Reload for use with 60 mm Linear cutter stapler with fresh knife & safety lock, Available in Pet Blister ray, Reload should have an open leg length of 3.8 mm (Blue Reload), 4.8 mm (Green Relaod) and Closed Staple Height of 1.5 mm (Blue Reload), 2.0 mm (Green Reload, Staple Lenght of 6 mm & Cut Lenght of 60 mm |
| 1060 | Disposable Blue Reload/ Green Reload for use with 80 mm Linear Cutter Stapler with fresh knife & Safety lock, Available in PET Blister Tray, Reload should have an open Leg Length of 3.8 mm (Blue Reload), 4.8 mm (Green Reload) and Closed Staple Height of 1.5 mm (Blue Reload), 2.0 mm (Green Reload) Statple Length of 84 mm & Cut Length of 80 mm |
| 1061 | Disposable Hemorrhoidal Circular Stapler 34 mm/ 36 mm with Three Circular Staggered Staple Lines (3 Rows) and Optimized Staple Formation Technique, Tissue Compression Indicator, housing capacity 14cc, Total 48 Titanium Staple Pins with Open Staple Leg Length of 3.5 mm which can accommodate compressed tissue thichness from 0.75 to 1.6 mm |
| 1062 | Non Oxidized Regenerated Cellulose and Bioabsorbable CE Class IIb or Class III Approved Hemostat.Forms 3D Gel and Effective in Mild, Moderate and Severe bleeding management during surgical procedures.(WoundClot Surgical) / CE & USFDA |
| 1063 | Non Oxidized Regenerated Cellulose and Bioabsorbable CE Class IIb or Class III Approved Hemostat.Forms 3D Gel and Effective in Mild, Moderate and Severe bleeding management during trauma .(WoundClot Trauma)/ CE & USFDA |
| 1064 | Non Oxidized Regenerated Cellulose and Bioabsorbable CE Class IIb or Class III Approved Hemostat.Forms 3D Gel and Effective in Mild, Moderate and Severe bleeding management during trauma .(WoundClot Trauma)/ CE & USFDA |
| 1065 | Waterproof Cast & Bandage Protector • PVC (Polyvinyl Chloride) • PPE (Polypropylene Elastomer) • Silicone (for the barrier) • Latex-Free: The product must be free of latex to prevent allergic reactions. • Elasticity: Must provide sufficient stretch and durability.Waterproofing: 100% waterproof, tested for complete protection against water penetration. • Durability: Must last through daily use for a minimum of 4-6 weeks without significant wear. • Temperature Resistance: Able to withstand warm water up to 40°C.ISO Certification: ISO 13485 or equivalent.• Safety Standards: Compliance with FDA, CE Marking, or BIS standards.• Biocompatibility Testing: Ensures the product is safe for prolonged contact withskin |
| 1066 | Waterproof Cast & Bandage Protector • PVC (Polyvinyl Chloride) • PPE (Polypropylene Elastomer) • Silicone (for the barrier) • Latex-Free: The product must be free of latex to prevent allergic reactions. • Elasticity: Must provide sufficient stretch and durability.Waterproofing: 100% waterproof, tested for complete protection against water penetration. • Durability: Must last through daily use for a minimum of 4-6 weeks without significant wear. • Temperature Resistance: Able to withstand warm water up to 40°C.ISO Certification: ISO 13485 or equivalent.• Safety Standards: Compliance with FDA, CE Marking, or BIS standards.• Biocompatibility Testing: Ensures the product is safe for prolonged contact withskin |
| 1067 | Waterproof Cast & Bandage Protector • PVC (Polyvinyl Chloride) • PPE (Polypropylene Elastomer) • Silicone (for the barrier) • Latex-Free: The product must be free of latex to prevent allergic reactions. • Elasticity: Must provide sufficient stretch and durability.Waterproofing: 100% waterproof, tested for complete protection against water penetration. • Durability: Must last through daily use for a minimum of 4-6 weeks without significant wear. • Temperature Resistance: Able to withstand warm water up to 40°C.ISO Certification: ISO 13485 or equivalent.• Safety Standards: Compliance with FDA, CE Marking, or BIS standards.• Biocompatibility Testing: Ensures the product is safe for prolonged contact withskin |
| 1068 | Waterproof Cast & Bandage Protector • PVC (Polyvinyl Chloride) • PPE (Polypropylene Elastomer) • Silicone (for the barrier) • Latex-Free: The product must be free of latex to prevent allergic reactions. • Elasticity: Must provide sufficient stretch and durability.Waterproofing: 100% waterproof, tested for complete protection against water penetration. • Durability: Must last through daily use for a minimum of 4-6 weeks without significant wear. • Temperature Resistance: Able to withstand warm water up to 40°C.ISO Certification: ISO 13485 or equivalent.• Safety Standards: Compliance with FDA, CE Marking, or BIS standards.• Biocompatibility Testing: Ensures the product is safe for prolonged contact withskin |
| 1069 | Waterproof Cast & Bandage Protector • PVC (Polyvinyl Chloride) • PPE (Polypropylene Elastomer) • Silicone (for the barrier) • Latex-Free: The product must be free of latex to prevent allergic reactions. • Elasticity: Must provide sufficient stretch and durability.Waterproofing: 100% waterproof, tested for complete protection against water penetration. • Durability: Must last through daily use for a minimum of 4-6 weeks without significant wear. • Temperature Resistance: Able to withstand warm water up to 40°C.ISO Certification: ISO 13485 or equivalent.• Safety Standards: Compliance with FDA, CE Marking, or BIS standards.• Biocompatibility Testing: Ensures the product is safe for prolonged contact withskin |
| 1070 | Waterproof Cast & Bandage Protector • PVC (Polyvinyl Chloride) • PPE (Polypropylene Elastomer) • Silicone (for the barrier) • Latex-Free: The product must be free of latex to prevent allergic reactions. • Elasticity: Must provide sufficient stretch and durability.Waterproofing: 100% waterproof, tested for complete protection against water penetration. • Durability: Must last through daily use for a minimum of 4-6 weeks without significant wear. • Temperature Resistance: Able to withstand warm water up to 40°C.ISO Certification: ISO 13485 or equivalent.• Safety Standards: Compliance with FDA, CE Marking, or BIS standards.• Biocompatibility Testing: Ensures the product is safe for prolonged contact with skin the silicone barrier, anti-slip grip, and the PVC hanging hole |
| 1071 | Waterproof Cast & Bandage Protector • PVC (Polyvinyl Chloride) • PPE (Polypropylene Elastomer) • Silicone (for the barrier) • Latex-Free: The product must be free of latex to prevent allergic reactions. • Elasticity: Must provide sufficient stretch and durability.Waterproofing: 100% waterproof, tested for complete protection against water penetration. • Durability: Must last through daily use for a minimum of 4-6 weeks without significant wear. • Temperature Resistance: Able to withstand warm water up to 40°C.ISO Certification: ISO 13485 or equivalent.• Safety Standards: Compliance with FDA, CE Marking, or BIS standards.• Biocompatibility Testing: Ensures the product is safe for prolonged contact with skin the silicone barrier, anti-slip grip, and the PVC hanging hole |
| 1072 | Waterproof Cast & Bandage Protector • PVC (Polyvinyl Chloride) • PPE (Polypropylene Elastomer) • Silicone (for the barrier) • Latex-Free: The product must be free of latex to prevent allergic reactions. • Elasticity: Must provide sufficient stretch and durability.Waterproofing: 100% waterproof, tested for complete protection against water penetration. • Durability: Must last through daily use for a minimum of 4-6 weeks without significant wear. • Temperature Resistance: Able to withstand warm water up to 40°C.ISO Certification: ISO 13485 or equivalent.• Safety Standards: Compliance with FDA, CE Marking, or BIS standards.• Biocompatibility Testing: Ensures the product is safe for prolonged contact with skin the silicone barrier, anti-slip grip, and the PVC hanging hole |
| 1073 | Waterproof Cast & Bandage Protector • PVC (Polyvinyl Chloride) • PPE (Polypropylene Elastomer) • Silicone (for the barrier) • Latex-Free: The product must be free of latex to prevent allergic reactions. • Elasticity: Must provide sufficient stretch and durability.Waterproofing: 100% waterproof, tested for complete protection against water penetration. • Durability: Must last through daily use for a minimum of 4-6 weeks without significant wear. • Temperature Resistance: Able to withstand warm water up to 40°C.ISO Certification: ISO 13485 or equivalent.• Safety Standards: Compliance with FDA, CE Marking, or BIS standards.• Biocompatibility Testing: Ensures the product is safe for prolonged contact with skin the silicone barrier, anti-slip grip, and the PVC hanging hole |
| 1074 | Waterproof Cast & Bandage Protector • PVC (Polyvinyl Chloride) • PPE (Polypropylene Elastomer) • Silicone (for the barrier) • Latex-Free: The product must be free of latex to prevent allergic reactions. • Elasticity: Must provide sufficient stretch and durability.Waterproofing: 100% waterproof, tested for complete protection against water penetration. • Durability: Must last through daily use for a minimum of 4-6 weeks without significant wear. • Temperature Resistance: Able to withstand warm water up to 40°C.ISO Certification: ISO 13485 or equivalent.• Safety Standards: Compliance with FDA, CE Marking, or BIS standards.• Biocompatibility Testing: Ensures the product is safe for prolonged contact with skin the silicone barrier, anti-slip grip, and the PVC hanging hole |
| 1075 | Waterproof Cast & Bandage Protector • PVC (Polyvinyl Chloride) • PPE (Polypropylene Elastomer) • Silicone (for the barrier) • Latex-Free: The product must be free of latex to prevent allergic reactions. • Elasticity: Must provide sufficient stretch and durability.Waterproofing: 100% waterproof, tested for complete protection against water penetration. • Durability: Must last through daily use for a minimum of 4-6 weeks without significant wear. • Temperature Resistance: Able to withstand warm water up to 40°C.ISO Certification: ISO 13485 or equivalent.• Safety Standards: Compliance with FDA, CE Marking, or BIS standards.• Biocompatibility Testing: Ensures the product is safe for prolonged contact with skin the silicone barrier, anti-slip grip, and the PVC hanging hole |
| 1076 | Waterproof Cast & Bandage Protector • PVC (Polyvinyl Chloride) • PPE (Polypropylene Elastomer) • Silicone (for the barrier) • Latex-Free: The product must be free of latex to prevent allergic reactions. • Elasticity: Must provide sufficient stretch and durability.Waterproofing: 100% waterproof, tested for complete protection against water penetration. • Durability: Must last through daily use for a minimum of 4-6 weeks without significant wear. • Temperature Resistance: Able to withstand warm water up to 40°C.ISO Certification: ISO 13485 or equivalent.• Safety Standards: Compliance with FDA, CE Marking, or BIS standards.• Biocompatibility Testing: Ensures the product is safe for prolonged contact with skin the silicone barrier, anti-slip grip, and the PVC hanging hole |
| 1077 | Sterile disposable single-use skin stapler with SS 316L staples having dimensions approximately 5.7 mm width, 3.9 mm closed height and 0.6 mm wire diameter. Handle should be made of medical grade ABS with polycarbonate cartridge and SS 304 guideway/pusher. Device should ensure consistent staple formation with precision press-fit technology for reliable firing performance. Product should be supported with indigenous manufacturing certificate from the manufacturer Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender