Housing Urban and Rular Development Government Departments Closing in 16 days TDR #56284817

Tender For Supply Installation Testing and Commissioning of 125 Kva Dg Set At Khalisani Mahavidyalaya,Chandannagar Hooghly---Electrical Installation Works

Issued by Government Departments · Hooghly, West Bengal
Tender Value
12.01 Lakhs
Estimated cost
Bid Submission
20 Jul 2026
16 days left
EMD
24039
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Hooghly → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply Installation Testing and Commissioning of 125 Kva Dg Set At Khalisani Mahavidyalaya,Chandannagar Hooghly---Electrical Installation Works

BOQ

Name of Work:- SITC of 125 KVA DG Set at Khalisani Mahavidyalaya,Chandannagar Hooghly---Electrical Installation Works
Sl. No. Item Description
1Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.( Make - Legrand/ Schneider/ Crabtree) as per direction of EIC. )6 Way Make - Legrand, Enclosure-607715/ Schneider Enclosure-/ Crabtree, Enclosure- ()/L&T [14 / D- 10]
2Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall as per GS as per direction of EIC. 4 way upto 160A ( Make - Legrand/Schneider/L&T ) [15 / D- 11]
3Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as per GS [Make-Legrand/ Schneider/Siemens/ Crabtree/ L&T) as per direction of EIC. ]40 A FP [ 6 / D- 5 ]
4Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make-Legrand/ Schneider/Siemens/Crabtree/L&T) as per direction of EIC. ]6-32 SP [ 7 / D- 6]
5Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA in existing Vertical DBs including necessary connection as per GS. [Make - Legrand / Schneider/L&T) as per direction of EIC.]160 A [10/D-8]
6Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make-Legrand/ Schneider/Siemens/Crabtree/L&T) as per direction of EIC. ]63 A TP [ 7 / D- 6 ]
7Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the 19mm/25mm prelaid polythene pipe/PVC rigid conduit as per GS. 2x(6 sqmm)+1x (4 sqmm) (TPN to mains witch ) [ 1(y) / E- 9 ]
84x(10 sqmm)+2x (6 sqmm) (VTPN to TPN ) [ 1(d1) / E- 9 ]
935 sqmm (Interconnection )
10Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] of following sizes on wall, ceiling with saddles and other accessories as required and mending good damages to building works20 mm size [ 7(a)/ E- 16 ]
11Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes4 sq mm [9(ii) / F-5]
126 sq mm [9(iii) / F-5]
1310 sq mm [9(iv) / F-5]
1435 sq mm
15Supply of 4/3.5/2 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [Make- Gloster/KEI/Havells/Mescab as approved by E.I.C]4 Core 95 Sq.mm.
164 Core 70 Sq.mm.
17Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy mending good damages and painting. [ 2(d)/ F- 1 ]
18Laying of cable above 3½ core 90 sqmm and upto 3½ core 150 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting [ 2(e)/ F- 1 ]
19Laying of cable in underground trench as per GS for the following numbers of Cables.above 35 upto 185 Sq. mm [1(b)/ F- 2 ]
20Supplying & fixing medium gauge GI Pipe (ISI-Medium) Protection with necessary fittings as per GS.40mm dia [11(c)/F-6]
21Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :4 Core 95 Sq. mm [7(c)/F4 ]
224 Core 70 Sq. mm [7(c)/F4 ]
23Finishing the end of following XLPE/PVC armoured cables by crimping method incl.supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :4 Core 95 Sq. mm [ 8(b- xviii) /F5]
244 Core 70 Sq. mm [ 8(b- xvii) /F5]
25Supplying and fixing 240V ,32A, DP Main Switches with Fuse on Phase and Neutral on flat iron frame on wall [1(a)/D-1] (For pump & wall bracket light)
26Supplying and fixing 415V TPN SFU with sheet steel enclosure of following rating on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. ( Make - L&T / Siemens /Havells)(D-3/4(a))250A, TPN SFU [4(a)/D-3] Incomming
27100A, TPN SFU [4(a)/D-3] old building to new building
2863A, TPN SFU [4(a)/D-3] new to old buildings
29Supplying and fixing 415V, TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nutsbolts etc ( Make - L&T / Siemens /Havells)(D-2/3(a))250 A, TPN SFU for 125 kva DG
30125 A, TPN SFU new building C/O to energengy busbar
31Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – (As per Drawing no. 470 of PWD Specification Book – May 1991)4 bars of rating- 415 V, 415 A with dimension of Cu bars [85mm long] :- (4 x 50x5mm) ; Dimension of Sheet Metal Box:- 500x150mm. [19(b)/D-13]--
324 bars of rating- 415 V, 125 A with dimension of Cu bars [85mm long] :- (4 x 15x5mm) ; Dimension of Sheet Metal Box:- 500x150mm. [19(b)/D-13]--
33Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required [4(a)/G-2]
34Excavation of soil for installation of Earth Electrode and filling & ramming for Morrum Soil. [1(b)/G-1]
35Earthing with 50 mm dia TATA medium GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level [ 2(a)/G-1]
36Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. [5(d)/G-3]
37Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. No. 4 SWG [5(a)(i)/G-2 ]
38S& delivery 70 sq. mm. single core multistrand PVC insulated flexible Cu cable and uPVC pipe (for neutral earthing)
39Laying only Cable above 50 sqmm but not exceeding 400sqmm through existing RCC/ Hume/GI Pipe/open masonary trench for single, 2, 3, 3½ and 4 core. [3(b)/F-1].
40Finishing the cable ends by crimping method incl. S&F copper socket, insulating tape and jointing materials etc. as required suitable for single core 70 sq. mm. copper wire.
41Supply & fixation of 4’’ dia M.S. Pipe for exhaust line including flange, gasket, clamp, nut, bolt, washer & rain cap, cladding of 4’’ dia exhaust pipe with Glass wool duly covered with wire net and Aluminium sheet etc.
42S&F special type MS angle iron bracket support made of 40x40x6 mm. MS angle with flat iron clamp with nuts, bolts & washers etc. for 100 mm. dia MS black pipe. (Vertical Run).
43Filling of HSD oil for initial refill with transportation.
44Supply and delivery of best quality oil hand pump with 1\\" dia PVC flexible pipe (10 mtr. approx.)
45Supply and delivery of 200 ltr. Capacity heavy gauge MS sheet barrel
46Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS . [ 2(a)/G-1]
47Connecting the equipment with 25mmx6mm galvanised MS hot dip flat on wall/floor as to GS. [5d/G-3]
48Earth work in excavation of foundation trenches of drains, in all sorts of soil including removing, spreading or stacking the spoils within a lead of 75m as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.( Depth of Excavation not exceeding 1500 mm )[ Page- 1, Item no.- 2(a) of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
49Earth work in filling in foundation trench or plinth with good earth in layers Board a) With earth obtained from excavation of foundation 1/5th of excavated earth [ Page 1, Item no.3(a) of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
50Filling in foundation or plinth by silver sand in layer With earth obtained from excavation of foundation 1/5th of excavated earth [ Page- 2, Item no.- 4(A) of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
51Single Brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand [ Page- 14, Item no.1 of PWD Schedule of Rates, Volume-I of Building Works, 2017]
52Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.. A)For works in foundation and top of ground floor / upto 4 m i) Tor steel/ Mild steel SAIL/ TATA/RINL. [ Page- 43, Item no.40(a)(i)(I) of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
53Ordinary cement concrete (mix 1:1.5:3) with graded stone chips (20 mm size) including shuttering and reinforcement, if any, in ground floor as per relevant IS codes ( Pakur variety ) [ Page 26, item no.10 of PWD Schedule for Building works with latest ammendmen ]
54Brick work with 1st class bricks in cement mortar (1:4) In foundation and plinth. [ Page- 16, item no.-13(a)-(i) of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
55Plaster (to wall, floor, ceiling etc.) of 10 mm thick with sand and cement with 1:4 cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] [ Page- 189, item no.-1(ii)-(c) of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
56Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE: Cement 0.152 cu.m per 100 sq.m. [ Page- 192, item no.-15 of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
57Add GST @18%:- Rs
58Add LWC @1% Rs. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56284817
AUTHORITY Government Departments
TENDER VALUE 12.01 Lakhs
LAST DATE 20-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for Supply Installation Testing and Commissioning of 125 Kva Dg Set At Khalisani Mahavidyalaya,Chandannagar Hooghly---Electrical Installation Works
Basic Detail
Tender No WBPWD/EE/ HED / NIeT-74 of 2026-27
Bidding Type Tender
Location
City Hooghly
State West Bengal
Key Dates
Publish Date 03 Jul 2026
Submission Date 20 Jul 2026
Open Date 22 Jul 2026
Finance
Tender Value 12.01 Lakhs
Tender Fee Ref. Documents
EMD 24039
Exemption Not Available
Document List
b198c5e9-11e3-4fe6-8531-64a94a776319.html
BOQ_5085720.xls
Tendernotice_1 (15).pdf
Tendernotice_2 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Jul 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
html

b198c5e9-11e3-4fe6-8531-64a94a776319.html

xls

BOQ_5085720.xls

pdf

Tendernotice_1 (15).pdf

pdf

Tendernotice_2 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender