Project Description

Tender for Work Of Electrification Of Hostel/Barrack And 01 Investigation Room For 32 Personnel In Hathras Junction Police Station Of Hathras District.

BOQ

Name of Work:- जनपद हाथरस के थाना हाथरस जंक्शन में 32 कर्मियों के लिए हॉस्टल /बैरक एवं 01 विवेचना कक्ष के विद्युतीकरण का कार्य ।
Sl. No. Item Description
1PART-A HOSTEL /BARRACK:-Wiring for light point/Fan point/exhaust fan point/call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable recessed medium class PVC conduit with modular type switch, modular plate, suitable GI box and with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc as required group B
2Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
3Supplying and Fixing 3 pin 5 A ceiling rose on the existing junction box including connections etc as required
4Supplying and Fixingpvc batten/angle holder including connections etc as required
5Supplying and Fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch connections etc as required
6Supplying and Fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 A& 15/16A modular socket outlet and15/16 A modular switch connections etc as required
7Supplying and drawing of 1x1.5 sqmm of FRLS PVC insulated copper conductor, single core (multi stranded) cable in the existing surface/ recessed steel/ PVC conduit as required.
8Supplying and fixing 4 way (4+12) double door horizontal type three pole and netural ,sheet steel , MCB distribution board 415 V on Surface/recess complete with tinned copper busbar, neutral bus bar ,din bar , interconnections, powder painted including earthing etc as required (But without MCB/RCCB/Insultor)
9Supplying and fixing 8way spndb double door single pole and netural ,sheet steel , MCB distribution board 230 V on Surface/recess complete with tinned copper busbar, neutral bus bar ,din bar , interconnections, powder painted including earthing etc as required (But without MCB/RCCB/Insultor)
10Supplying and fixing 12way spndb double door single pole and netural ,sheet steel , MCB distribution board 230 V on Surface/recess complete with tinned copper busbar, neutral bus bar ,din bar , interconnections, powder painted including earthing etc as required (But without MCB/RCCB/Insultor)
11Supplying and fixing 5 A to 32 A rating 240/415 V 10 kA C Curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc as required single pole
12Supplying and fixing 5 A to 32 A rating 240/415 V 10 kA C Curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc as required double pole
13Wiring For circuit /Submain wiring alonwith earthwire the following sizes of FRLS PVC insulated copper conductor single core cable in recessed medium class pvc conduit as required size 2x1.5 sqmm +1x1.5 sqmm earth wire
14Wiring For circuit /Submain wiring alonwith earthwire the following sizes of FRLS PVC insulated copper conductor single core cable in recessed medium class pvc conduit as required size 2x2.5 sqmm +1x2.5 sqmm earth wire
15Wiring For circuit /Submain wiring alonwith earthwire the following sizes of FRLS PVC insulated copper conductor single core cable in recessed medium class pvc conduit as required size 2x4 sqmm +1x4 sqmm earth wire
16Wiring For circuit /Submain wiring alonwith earthwire the following sizes of FRLS PVC insulated copper conductor single core cable in recessed medium class pvc conduit as required size 2x6 sqmm +1x6 sqmm earth wire
17Wiring For circuit /Submain wiring alonwith earthwire the following sizes of FRLS PVC insulated copper conductor single core cable in recessed medium class pvc conduit as required size 4x6 sqmm +2x6 sqmm earth wire
18Wiring For circuit /Submain wiring alonwith earthwire the following sizes of FRLS PVC insulated copper conductor single core cable in recessed medium class pvc conduit as required size 4x10 sqmm +2x6 sqmm earth wire
19Earthing with G I earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
20Providing and fixing 25 mm X 5 mm G I strip on surface or in recess for connections etc. as required.
21Installation of exhaust fan in the existing opening including making good the damage connection testing commissioning etc as required.upto 450 mm sweep
22Extra for fixing the louvers / shutters complete with frame for exhaust fans of all sizes.
23Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
24S/F Single pole MCB blanking plate
25LED Batten light (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement withDriver efficiency >85% ,Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing complete in all respect i/c external connections with 1.5 sqmm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test Powder Coated CRCA Sheet Body (Thickness > 0.50 mm)report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).18- 22 Watt
26LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt). Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protectionEMI- EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 50 watt
27Supply & fixing of water tight-oblong 10 watt LED Bulkhead luminaire having pressure die cast housing with driver set confirming to IP65 and above protection, IK 08, High purity /transmisivity UV Stabilized Non yellowish diffuser/ for uniform light distribution, detachable driver set, open and short circuit protection, suitable for 24 [Ir Continuous Operation, Complete in All respect, compelete in all respect1100 system lumens, >110Lm/W, PF>0.95, CRI >70, with 3 years warrantee
28Supply and fixing of IP 20, Front Lit, Mid Power SMD type: LED Light, recess Surface in otinting round 6 Watt to 9 Walt, Cut out Min 125mm; Height Min 40 mm, LED Down Lighter having Powder coated die cast aluminium Latising with heat sink, High purity/ transmisivity UV Stabilized Non yellowish diffuser/Reflector for uniform light distribution, detachable driver set. suitable for 24 Hr. Continuous Operation, Complete in. All respect. 1660-990 systein lumens, >110 Lm/W, PF>0.95, THD <10% at full lead; CRI>80 with 3 years warrantee.
29Supply and Laying of Aluminium Conductor PVC insulated armoured served sheathed cables 1100V grade at a depth of 750mm below ground level over a cushion of 75mm thick sand ali around and protected with burnt bricks on sides and on top as directed by Engineer in Charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.95 Sq mm 3.5 Core
30S/f of brass nickle plated compression gland 95sqmm 3.5 core
31Supply of Fresh Air Fan fan 300mm sweep single phase 900rmp 230/250V, 50 hz (light duty)
32Supply of Fresh Air Fan fan 300mm sweep single phase 900rmp 230/250V, 50 hz (Heavy duty)
33Supply and fixing LED Bulb 12 watt lumen 810 to 945 complete in all respect.
34S/L of 1800x900x12 mm thick chequred rubber mating of tested and quality
35S/F of shock Treatmemt Chart (prescribed under IE rules)
36S/F of hexagonal Fan box
37S/F of lug 1.5 to 2.5 sqmm
38S/F of lug 4 sqmm
39S/F of lug 6 sqmm
40S/F of lug 10 sqmm
41S/F of lug 95 sqmm
42supply and fixing of fire extinguisher ABC Type 6.00kg capacity (ISI Marked IS : 15683 & TAC approved ) complete with initial charge and wall bracket along with supply of all material and labour for proper complete of work.
43supply and fixing of fire extinguisher C02 Type 6.50kg capacity (ISI Marked IS : 2878 & TAC approved ) complete with initial charge and wall bracket along with supply of all material and labour for proper complete of work.
44s/f of fire bucket , round bottom made of G.I sheet 9-11 litre capacity duly painted as fire bridgede design suported on hanging bracet chained and locked initialy filled with fine sand com. In all respact
45Supplying and fixing 6 to 32 A rating four pole MCB 10 KA C Curve
46Supply & Erection of factory fabricated & wired metal clad dust and vermin proof floor mounting. M.S. Channel Base with bottom and top cable entries Electrical Control Panel with TPN MCCB's (Four Pole 36KA) with thermal magnetic release) Complete and instrument chamber etc., complete in all respect. The Instrument Chamber shall be separate and shall comprise of flush type digital metering system for phase-to-phase voltage and single-phase voltage, current and other parameter (KVA, PF, KW etc.) in each phase with touch type Selector switches for different readings, instrument fuses, current transformer etc. The Panel Board shall have suitable capacity electrolytic Aluminum Busbar insulated with heat shrink sleeving and mounted on non-hygroscopic support such as CMC/DMC support with detachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp an incoming etc.The job includes the grouting of the board as per directions of Engineer-in-charge. All outgoings of 100Amp and above shall have an ammeter. The switch board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switchboard shall be of cat A & B only.INCOMING:-1. MCCB 150A FP 36KA -01No2. DIGITAL METERING (MFM) -01 Set3. PHASE INDICATOR (R,Y,B) -01 SetOUTGOING: -1. MCCB 32A FP 36KA -05 Nos.BUS BARS:-1. 150A FP ALUMINIUM BUSBAR -01 Set
47PART-B Vivechana RoomWiring for light point/Fan point/exhaust fan point/call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable recessed medium class PVC conduit with modular type switch, modular plate, suitable GI box and with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc as required group C
48Supplying and Fixing 3 pin 5 A ceiling rose on the existing junction box including connections etc as required
49Supplying and Fixing pvc batten/angle holder including connections etc as required
50Supplying and Fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch connections etc as required
51Supplying and Fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 A & 15/16A modular socket outlet and15/16 A modular switch connections etc as required
52Supplying and drawing of 1x1.5 sqmm of FRLS PVC insulated copper conductor, single core (multi stranded) cable .for Inverter in the existing surface/ recessed steel/ PVC conduit as required.
53Supplying and fixing 4 way double door horizontal type TPNDB,sheet steel , MCB distribution board 415v, on Surface/recess complete with tinned copper busbar, neutral bus bar ,din bar , interconnections, powder painted including earthing etc as required (But without MCB/RCCB/Insultor)
54Supplying and fixing 12 way double door horizontal type SPNDB,sheet steel , MCB distribution board on Surface/recess complete with tinned copper busbar, neutral bus bar ,din bar , interconnections, powder painted including earthing etc as required (But without MCB/RCCB/Insultor)
55Supplying and fixing 5 A to 32 A rating 240/415 V 10 kA C Curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc as required single pole Single pole
56Double pole
57Tripple pole & Neutral
58Wiring For circuit /submin wiring alonwith earthwire the following sizes of FRLS PVC insulated copper conductor single core cable in recessed medium class pvc conduit as required size 2x2.5 sqmm +1x2.5 sqmm earth wire
59Wiring For circuit /submin wiring alonwith earthwire the following sizes of FRLS PVC insulated copper conductor single core cable in recessed medium class pvc conduit as required size 2x4 sqmm +1x4 sqmm earth wire
60Wiring For circuit /submin wiring alonwith earthwire the following sizes of FRLS PVC insulated copper conductor single core cable in recessed medium class pvc conduit as required size 2x6 sqmm +1x6 sqmm earth wire
61Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
62Providing and fixing 25 mm X 5 mm G I strip on surface or in recess for connections etc. as required.
63Installation of exhaust fan in the existing opening including making good the damage connection testing commissioning etc as required.upto 450 mm sweep
64Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies,shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion)less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperaturerise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
65S&F single pole MCB blanking plate
66Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
67Extra for fixing the louvers / shutters complete with frame for exhaust fans of all sizes.
68Supplying and drawing following pair 0.5 sqmm FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required.2 Pair
69Supply and fixing of following size of PVC conduit alongwith the accessories in recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required:25mm
70Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.Telephone socket outlet
71Supplying and fixing following size/modules, Gl box alon with modular base & cover plate for modular switches i recess etc as required.1 or 2 module (75mm X 75 mm)
72LED Batten light (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement withDriver efficiency >85% ,Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing complete in all respect i/c external connections with 1.5 sqmm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test Powder Coated CRCA Sheet Body (Thickness > 0.50 mm)report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).18- 22 Watt
73LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt). Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protectionEMI- EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 50 watt
74Supply & fixing of water tight-oblong 10 watt LED Bulkhead luminaire having pressure die cast housing with driver set confirming to IP65 and above protection, IK 08, High purity /transmisivity UV Stabilized Non yellowish diffuser/ for uniform light distribution, detachable driver set, open and short circuit protection, suitable for 24 [Ir Continuous Operation, Complete in All respect, compelete in all respect 1100 system lumens, >110Lm/W, PF>0.95, CRI >70, with 3 years warrantee
75Supply and Laying of Aluminium Conductor PVC insulated armoured served sheathed cables 1100V grade at a depth of 750mm below ground level over a cushion of 75mm thick sand ali around and protected with burnt bricks on sides and on top as directed by Engineer in Charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 10Sq mm 4 Core
76S/F brass compression gland for size 10sqmm 4 core
77Supply and fixing LED Bulb 12 watt lumen 810 to 945 complete in all respect.
78S/F of lug 4 sqmm
79S/F of lug 10 sqmm
80S/F of lug 2.5 sqmm
81S/F of lug 6 sqmm
82S/F of hexagonal Fan box
83supply and fixing of fire extinguisher ABC Type 4.00kg capacity (ISI Marked IS : 15683 & T&P approved ) complete with initial charge and wall bracket along with supply of all material and labour .
84Supply of fresh air Fan 300mm 1-phase 900 rpm,230/250 volts,50Hz.
85Supply and Fixing of Lamp based LED 11W Luman 800 mirror light complete in all respect. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56284530
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 17-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for Work Of Electrification Of Hostel/Barrack And 01 Investigation Room For 32 Personnel In Hathras Junction Police Station Of Hathras District.
Basic Detail
Tender No 481/6WE(ALI)-E/M CIRCLE AGRA/2026-27 DT 18.06.2026
Bidding Type Tender
Location
City Aligarh
State Uttar Pradesh
Key Dates
Publish Date 03 Jul 2026
Submission Date 17 Jul 2026
Open Date 17 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee 854
EMD 1.46 Lakhs
Exemption Not Available
Document List
52c85d1c-5510-4661-8b9e-fd53d8e5fed8.html
BOQ_2187133.xls
ELECTRICALCONDITION.pdf
T1.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Jul 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
html

52c85d1c-5510-4661-8b9e-fd53d8e5fed8.html

xls

BOQ_2187133.xls

pdf

ELECTRICALCONDITION.pdf

pdf

T1.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders