Tender For Addition Alteration To Living In Offrs Accn At Af Stn Halwara Under Ge (Af) Halwara
Tender Value
1.45 Crore
Estimated cost
Bid Submission
28 Jul 2026
19 days left
EMD
2.20 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
halwara → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Addition Alteration To Living In Offrs Accn At Af Stn Halwara Under Ge (Af) Halwara
BOQ
| Sl. No. | Item Description |
| 1 | Taking down chowkhats or frame with shutter w/o taking off shutter from the frame area exc 1.5 Sqm but n-exc 4 sqm each complete all as specified and directed by Engr-in-charge. |
| 2 | Taking down chowkhats or frame with shutter w/o taking off shutter from the frame area not exc 1.5 Sqm each complete all as specified and directed by Engr-in-charge. |
| 3 | Supply and Fixing Solid PVC door Frame of size 50mm x 47mm made out of 5mm single side pre laminated PVC sheet reinforced with MS square tube, edges will be painted to match with prelaminated sheet and fixing in opening complete all as specified and directed by Engr-in-charge. |
| 4 | Supply and Fixing Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded Prelam PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and Prelami colour PVC sheets for top rail, lock rail & bottom rail on both side & as gap insert for top rail & bottom rail; Panelling of prelam colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails feathered at edges with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site complete all as specified and directed by Engr-in-charge. |
| 5 | Factory made single extruded WPC (Wood polymer Composite) Solid door/window/ceosetory window/ & other frames/Chowkhat of size 65x100mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder / rice husk / wheat husk ) and non toxic additives (maximum toxicity index of 12 for 100 gms ) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS Screws having minimum frame density of 750 Kg /cum, screw withdrawal strenght of 2200N (face) & 1100N (Edge), minimum compressive strength of 58 N/mm Sqr, modules of elasticity 900 N/mm Sqr and resistance to spread of flame of Class A category with property of being termite / borer proof, water/ moisture proof and fire retardant and fixed in positon with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed by Engr-in-charge. Note:- 1. M.S. hold fast/lugs or SS dash fasteners shall be paid for separately. 2. For WPC solid door / window frame, minus 5mm tolerance in dimension ie. depth and width of profile shall be acceptable. variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 6 | Factory made single extruded WPC (Wood polymer Composite) Solid door/window/ceosetory window/ & other frames/Chowkhat of size 65x125mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder / rice husk / wheat husk ) and non toxic additives (maximum toxicity index of 12 for 100 gms ) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS Screws having minimum frame density of 750 Kg /cum, screw withdrawal strenght of 2200N (face) & 1100N (Edge), minimum compressive strength of 58 N/mm Sqr, modules of elasticity 900 N/mm Sqr and resistance to spread of flame of Class A category with property of being termite / borer proof, water/ moisture proof and fire retardant and fixed in positon with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer -in-Charge. Note:- 1. M.S. hold fast/lugs or SS dash fasteners shall be paid for separately. 2. For WPC solid door / window frame, minus 5mm tolerance in dimension ie. depth and width of profile shall be acceptable. variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 7 | Providing and fixing factory made single extruded WPC (Wood polymer Composite) Solid decorative type Flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (Wood powder/rice husk/wheat husk) and non toxiv additives ( maximaum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800N (Face) & 900 N (Edge), minimum compressive strenth 50 N/Sqmm, modulus of elasticity 850N/Sqmm and resistance to spread of flame of Class A category with property of being termite / borer proof, water/ moisture proof and fire retardan. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design passed with hot melt adhesive on both faces of shutter and fixing with stainless steel butt higes of required size with necessary full body threaded star headed counter sunk S S Screw, complete all as specified and directed by Engr-in-charge. (Note:- Stainless steel butt hinges and necessary SS Screws shall be paid separately). |
| 8 | Providing and fixing factory made single extruded WPC (Wood polymer Composite) Solid decorative type Skelton door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (Wood powder/rice husk/wheat husk) and non toxiv additives ( maximaum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800N (Face) & 900 N (Edge), minimum compressive strenth 50 N/Sqmm, modulus of elasticity 850N/Sqmm and resistance to spread of flame of Class A category with property of being termite / borer proof, water/ moisture proof and fire retardan. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design passed with hot melt adhesive on both faces of shutter and fixing with stainless steel butt higes of required size with necessary full body threaded star headed counter sunk S S Screw,including lipping of matching colour on edges, complete all as specified and directed by Engr-in-charge. (Note:- Stainless steel butt hinges and necessary SS Screws shall be paid separately). |
| 9 | Providing and fixing factory made uPVC white colour casement (Openable) window of area exc 2.0 Sqm each made of extruded profiles with wall thickness of 2.3mm (+ 0.2mm). Window profile with hollow section with multi chamber, frame (60mmx58mm), Sash (60mm x 73mm), T Profile (One vertical length in between two shutters) (60mm x 74mm), Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners including drilling of holes for fiixng hardware and drainage of water etc.,making arrangement for fixing of hardware. EPDM gasket 1.2 + 0.2mm thick galvanised steel frame (28mm x 21.5mm ), sash (31mm x 27.5mm) T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100 mm long fasteners. Hardware: ( casement handle made of zincalloyed (White powder coated),but hinges of zinc alloyed (White powder coated ), transmission gear made of mild steel with multi point locking system and 5mm thick glazing with selected quality glass complete all as specified and directed by Engr-in-charge.Note: (i) The unit rate quoted by contractor excludes cost of glass / wiremesh and includes all other connected accessoriees.(ii) Net opening will be measured for payment purpose. |
| 10 | Supply and Fixing Powder coated, minimum thickness of powder coating 50 micron aluminium frame for doors, windows, ventilators or in partitions with one or more rebates including joining cleat for fixing etc complete all as specified and directed by Engr-in-charge. |
| 11 | Supply and fixing Powder coating, minimum thickness of powder coating 50 micron aluminium window and ventilator shutters, side hung/fixed type without sash bars, aluminium section weighing 0.55 kg/ m including necessary joining cleats, zing clips, rubber neoprene packing, anodised aluminium snap beading screws anodised aluminium fittings such as peg stay, Tower bolt 150mm long 1 No. hinge type B-21, 100 mm long 2 Nos, suitable handle 1 No complete all as specified and as directed by Engr-in-charge. |
| 12 | Supply and Fixing of anodised aluminium grill (anodised transparent or dyed to required shade according to IS:1868 with minimum abodic coating of grade AC15) of approved design/pattern with approved standard section and fixed to existing window frame with C.P brass/stainless steel screw@200mm centre to centre,including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening ,complete all as specified and directed by Engr-in-charge. |
| 13 | Supply and fixing figured glass pin head type glazed with oil putty in square nexc 0.5 Sqm in each pan 5mm thick complete all as specified and directed by Engr-in-charge. |
| 14 | Supply and fixing in repair stainless steel wire cloth 0.36 mm nominal dia and average width of aperture 1.4 mm and fixed with stainless steel wire staples complete all as specified and directed by Engr-in-charge. |
| 15 | Supply and fixing 100 mm size butt hinges medium weight cold rolled mild steel complete all as specified and directed by Engr-in-charge. |
| 16 | Supply and fixing 150 mm long Floor door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring fixed in floor complete all as specified and directed by Engr-in-charge. |
| 17 | Supply and fixing 200 mm long Aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed by Engr-in-charge. |
| 18 | Supply and fixing 150mm long Aluminium handles cast type anodised complete all as specified and directed by Engr-in-charge. |
| 19 | Supply and fixing 300 mm long aluminum anodised sliding door bolts, Aluminium alloy,door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium complete all as specified and directed by Engr-in-charge. |
| 20 | Supply and fixing in repairs mild steel 300mm ordinary rat tail rod door spring , patteren including roller and roller plate complete all as specified and directed by Engr-in-charge. |
| 21 | Supply and fixing in repairs stainless steel hollow curtain rod 19/20mm dia with two Nos decorative type brackets knobs for each rod of length not exceeding 1.8 mtr including fixing with suitable arrangements including taking down existing complete all as specified and directed by Engr-in-charge. |
| 22 | Supply and fixing in repairs; stainless steel plate rack made out of 1mm thick steel sheet of size 75cm x 90cm x 25cm with fixing arrangements complete all as specified and as directed by Engineer-in-Charge. |
| 23 | Taking down cement plaster of any description thickness including raking out joints hacking for key scrubbing down with water complete all as specified and directed by Engr-in-charge. |
| 24 | Material and Labour for internal rendering 12 mm thick in cement mortar 1:6 on Brick or concrete surface finished even and smooth without using extra cement complete all as specified and directed by Engr-in-charge. |
| 25 | Material and Labour for preparation of new surfaces of walls and applying two coats of distemper oil emulsion over one coat of primer over 1mm thick plaster of paris putty, to prepare surface even and smooth complete all as specified and directed by Engr-in-charge. |
| 26 | Material and labour for complete removal of old decorated plastered & unplastered surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soot, mould, moss and efflorescent salts, trading oil and greasy spots and applying two coats of distemper oil emulsion over one coat of primer over 1mm thick plaster of paris putty, on old surfaces of wall complete all as specified and directed by Engr-in-charge. |
| 27 | Material and labour external rendering 1st coat of 10 mm thick in CM(1:6) and above 5mm thick in CM (1:4) as a 2nd coat of rendering with WPC (Note : WPC will be paid separately) complete all as specified and directed by Engr-in-charge. |
| 28 | Supply only integral waterproofing compound complete all as specified and directed by Engr-in-charge. |
| 29 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint over 1mm thick plaster of Paris putty, having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed by Engr-in-charge. |
| 30 | Material and labour plastering 5 MM thick in cement mortar (1:3) furnished even & smooth without using extra cement as on ceiling complete all as specified and directed by Engr-in-charge. |
| 31 | Preprationof new surfaces of and applying three coat of white wash on ceiling complete all as specified and directed by Engr-in-charge. |
| 32 | Material and labour for Prepration of old surfaces and applying one coat of white wash on ceiling complete all as specified and directed by Engr-in-charge. |
| 33 | Material and labour preparation of new steel surfaces of any description not otherwise described over 10 Cm width or girth and applying two coat of synthetic enamelled paint over one coat of red oxide primer complete all as specified and directed by Engr-in-charge. |
| 34 | Demolition of brick/stone masonry, built in cement mortar including all quoins, arches, pillars etc but exluding ashlars facings, dressed stone work and pre-cast concrete articles complete all as specified and directed by Engr-in-charge. |
| 35 | Material and labour for Brick work with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed by Engr-in-charge. |
| 36 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed by Engr-in-charge. |
| 37 | Material and labour 25 mm thick cement concrete type B0 1:2:4 using (12.5mm graded stone aggregate) in floor finishes even and rough to receive floor tiles complete all as specified and directed by Engr-in-charge. |
| 38 | Material and labour for Non skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) as in flooring area of each tile exc 0.11 Sqm but n.exc 0.18 Sqm, in neat cement slurry and pointed in white or coloured cement with pigment to match over 15mm thick screed bed in cement mortar (1:6) complete all as specified and directed by Engr-in-charge. |
| 39 | Material and labour for Glazed ceramic coloured tiles (450mm x 350mm)/(350mm x 250mm) x 6-7mm thick on vertical surfaces as in skirting/dado, set and jointed with neat cement slurry and pointed in white/coloured cement to match the shade of tiles over 10mm thick rendering in cement mortar 1:4 including necessary cutting as per site requirement complete all as specified and directed by Engineer-in-Charge. |
| 40 | Material and labour vitrified ceramic light shade tiles 10 mm thick (Square/rectangular) area of eac tile n.exc. 0.36 Sqm, in neat cement slurry and pointed in white or coloured ceemnt with pigment including 10mm thick bedding layer in cement mortar (1:6) including necessary cutting as per site requirement complete all as specified and directed by Engineer-in-Charge. |
| 41 | All as per item No. 40 here-in-before but as in skirting over 10mm thick rendering in cement mortar (1:4) complete all as specified and directed by Engr-in-charge. |
| 42 | Demolition of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar in floors, aprons etc complete all as specified and directed by Engr-in-charge. |
| 43 | Material and Labour granite slab (of any type) 20mm thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in 15mm thick screed bed of cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of granite complete all as specified and directed by Engr-in-charge. |
| 44 | Rounding to edges of stone slabs one edge, such as in steps,cooking platform, and other similar situation complete all as specified and directed by Engr-in-charge. |
| 45 | Material and Labour for machine cut kota stone slab 18 to 20 mm thick as in flooring / stair case landing, laid over & including 15mm thick cement screed bed in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and directed by Engr-in-charge. (Note:- Single piece in treads & 3 Nos of V groove is to be made in the edge) |
| 46 | Material and labour for machine cut kota stone slab 18 to 20mm thick as in skirting/steps of staircase laid over & including 10 mm thick cement screed bed in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as spcified and directed by Engr-in-charge. (Note:- Single piece in treads & 3 Nos of V groove is to be made in the edge) |
| 47 | Taking up or down 15mm dia steel tubing and connections and removal from site complete all as specified and directed by Engr-in-charge. |
| 48 | Taking up or down 20 mm dia steel tubing and connections and removal from site complete all as specified and directed by Engr-in-charge. |
| 49 | Supply and fixing 16mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed by Engr-in-charge. |
| 50 | Supply and fixing 20mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed by Engr-in-charge. |
| 51 | Supply and fixing in repair15mm size Bib taps, fancy type chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or forbrass ferrule and complete all as specified and directed by Engr-in-charge. |
| 52 | Supply and fixing in repair PVC connection 450 mm long, 15mm size with PTMT nuts complete all as specified and directed by Engr-in-charge. |
| 53 | Supply and fixing in repair 10 ltr PVC valve less symphonic action type flushing cistern, low level white with inlet ball valve float and handle with flush pipe complete all as specified and directed by Engr-in-charge. |
| 54 | Supply and fixing in repairs vitreous china wash basin, counter sunk white of size 550mmx400mm excluding taps, waste chain, waste pipe and plug and procelain stopper but including necessary granite cutting for and pinning in ends, waste coupling and waste pipe, complete all as specified and directed by Engr-in-charge. |
| 55 | Supply and fixing 32mm waste fittings, brass, chromium plated for glazed ware sinks, basin etc with long screwed shanks and flynuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed by Engr-in-charge. |
| 56 | Supply and fixing brass chromium plated tubular towel rail 20mm dia, D type 60cm long between flanges complete all as specified and directed by Engr-in-charge. |
| 57 | Supply and fixing brass chromium plated tubular towel ring 20mm dia complete all as specified and directed by Engr-in-charge. |
| 58 | Dismantling boarding, any description, fixed in any position with nails/ screws complete all as specified and directed by Engr-in-charge. |
| 59 | Material and Labour for factory made single extruded WPC (Wood polymer Composite) Solid door/window/ceosetory window/ & other frames/Chowkhat of size 45x70mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder / rice husk / wheat husk ) and non toxic additives (maximum toxicity index of 12 for 100 gms ) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS Screws having minimum frame density of 750 Kg /cum, screw withdrawal strenght of 2200N (face) & 1100N (Edge), minimum compressive strength of 58 N/mm Sqr, modules of elasticity 900 N/mm Sqr and resistance to spread of flame of Class A category with property of being termite / borer proof, water/ moisture proof and fire retardant and fixed in positon with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed by Engr-in-charge. Note:- 1. M.S. hold fast/lugs or SS dash fasteners shall be paid for separately). 2. For WPC solid door / window frame, minus 5mm tolerance in dimension ie. depth and width of profile shall be acceptable. variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 60 | Material and labour for factory made 18mm thick shutter made out of 100% solid WPC Plain board of required size comprising of virgin PVC resin of K value 57-60 ( suspension grade, calcium carbonate and natural fibres (Wood powders/rice husk/wheat husk) and non toxic additives, made from Extrusion process WPC foam sheet single Extruded (inner) with density not less than 650kg/Cum an ISO 9001-2015 certified company, having good screw holding capacity (screw withdrawal strength of 2000N (face) & 1100N(Edge), Minimum compressive strenth of 50N/sq mm, Modulus of elasticity 850N/Sq mm and resistance of spread of flame of class A category with property of being Termite/Borer free. Water/Moisture proof, fire retardant and fixing with SS butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws. All as per direction of Engg-in-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company : For WC/Bathroom/Cupboard/Kitchen/Balcony Doors& cabinets complete all as specified and directed by Engr-in-charge. Note : SS butt hinges and necessary ss screw shall be paid separartely |
| 61 | Supply and fixing Continuous (piano) hinges, 40mm mild steel, bright finish or electrogalvanised complete all as specified and directed by Engr-in-charge. |
| 62 | Hasp and staple, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws complete all as specified and directed by Engr-in-charge. |
| 63 | Supply and fixing Extruded aluminium alloy handles, fabricated type, anodised of size 100mm complete all as specified and directed by Engr-in-charge. |
| 64 | Supply and fixing 40mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, bright finished complete all as specified and directed by Engr-in-charge. |
| 65 | Supply and fixing in repair rotational moulded water stroage tank (cylinderical vertical with closed top) hoisted and fixed in position capacity 500 Ltrs with 20 mm PTMT float valve including taking down old water tanks complete all as specified and directed by Engr-in-charge. |
| 66 | Dismantling of any dia cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out from floors or walls complete all as specified and directed by Engr-in-charge. |
| 67 | Supply and fixing 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, step clamps, including all fittings (Any type of \\"T\\"/tee, bend, Y, Branch piece single/double, couplers, reducers, vent coil, access door, junction single/double, equal/unequal, any type of traps including grating etc), fixed to walls/floor/trenches etc and height of buildings upto Ground floor and first floor, complete all as specified and directed by Engr-in-charge. |
| 68 | Supply and fixing 110 mm dia, PVC (SWR) pipes single socketed, in any length with rubber ring joints, step clamps, including all fittings (Any type of \\"T\\"/tee, bend, Y, Branch piece single/double, couplers, reducers, vent coil, access door, junction single/double, equal/unequal, any type of traps including grating etc), fixed to walls/floor/trenches etc and height of buildings upto Ground floor and first floor complete all as specified and directed by Engr-in-charge. |
| 69 | Supply and fixing in repairs health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 m long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed by Engr-in-charge. |
| 70 | Supply and fixing wash down water closet (Pedastal pattern) incl seat cover and stainless steel water jet incl connection to drain pipe (Outgoing pipe) and to flush pipe, antisyphonage pipe etc complete all as specified and directed by Engr-in-charge. |
| 71 | Supply and fixing in repair PVC cabinet mirror 350mm x 450mm with 4mm thick frame mirror colour white, bathroom storage organiser/ Multipurpose Shelf/ Wall mount Mirror cabinet, complete all as specified and directed by Engr-in-charge. |
| 72 | Supply and fixing in repair CP brass shower rose 125mm size with or without swivel joints 125mm size including fixing to steel pipe or union complete all as specified and directed by Engr-in-charge. |
| 73 | Supply and fixing in repair CP brass mixer of bore dia 15mm for wash basin for mixing of hot & cold water screwed down for iron pipe and fixed complete all as specified and directed by Engr-in-charge. |
| 74 | Supply and fixing in repair CP brass mixer of bore dia 15mm for kitchen for mixing of hot & cold water screwed down for iron pipe and fixed complete all as specified and directed by Engr-in-charge. |
| 75 | Supply and fixing in repair CP brass wall mixer of dia 15mm for shower for mixing of hot & cold water screwed down for iron pipe and fixed complete all as specified and directed by Engr-in-charge. |
| 76 | Supply and fixing in repair sinks made of stainless steel1mm thick for kitchen or laboratory with plugs,waste pipe,washers and waste including cast iron cantilever brackets connecting union etc over all size 495mm x 420mm with bowl size 410mm x 330mm x160 mm complete all as specified and directed by Engr-in-charge. |
| 77 | Supply and fixing in repair PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed by Engr-in-charge. |
| 78 | Supply and fixing in repairs Stop valves of dia 15 mm , cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engr-in-charge. |
| 79 | Material and labour for mild steel TMT bars10mm dia and over cut to length bent to shape reqd including cranking ,bending spirally for hooping for columns hooking bends and binding with including mild steel wire (annealed) not-less than 0.9mm dia or securing with clips quality complete all as specified and directed by Engr-in-charge. |
| 80 | Material and labour for RCC(1:2:4), type B0 (12.5mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engr-in-charge. |
| 81 | Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed by Engr-in-charge. |
| 82 | Formwork to edges of rough finished surfaces of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 5cm but n exc 10cm wide complete all as specified and directed by Engr-in-charge. |
| 83 | Demolition of Reinforced cement concrete of any description and in any position not otherwise specficially provided for complete all as specified and directed by Engr-in-charge. |
| 84 | Demolition of unreinforced cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engr-in-charge. |
| 85 | Material and labour 60mm thick machine pressed precast concrete interlocking paver block with grey cement and pigment of any size and shape confirming to IS 15658-2006, M-35 Grade as approved by GE laid in flooring and joints filled/broomed with fine sand complete all as specified and directed by Engr-in-charge. |
| 86 | Material and labour for sand filling under floors or in foundations including watering and consolidation, complete all as specified and directed by Engr-in-charge. |
| 87 | Material and labour for 75 mm thick PCC 1:3:6 type C2 as in sub base etc complete all as specified and directed by Engr-in-charge. |
| 88 | Material and labour for 75 mm thick PCC 1:2:4 type B2 as in plinth protection/floor sub base etc complete all as specified and directed by Engr-in-charge. |
| 89 | Material and labour for Providing and injecting chemical emulsion for Post Constructional Anti-termite TreatmentAlong the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed by Engineer-in-charge. |
| 90 | Material and labour for Providing and injecting chemical emulsion for Post Constructional Anti-termite Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement :2 coarse sand) to match the existing floors complete all as specified and directed by Engr-in-charge. |
| 91 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engr-in-charge. |
| 92 | Supply and fixing rolled Mild steel work as in Roof trusses (Framed), trussed purlins, crane gantries, rails, and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleat etc- Quality Fe 410-w, (E-250 Grade A Quality) complete all as specified and directed by Engr-in-charge. |
| 93 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exc 10cm but not exc 20 cm girth complete all as specified and directed by Engr-in-charge. |
| 94 | Supply and fixing pre-painted galvalume aluminium zinc coating GI based semi corrugated / trapezoidal / suitable profile steel sheet 0.50 mm thick of a colour as approved having tensile strength of 550 Mpa fixed with self tapping screws after taking down old AC sheets complete all as specified and directed by Engr-in-charge. |
| 95 | Supply and fixing of Toughened Glass 10 mm thick as in hinged doors, partitions, automatic doors and similar work including cutting to shape, drilling holes required including glazing with beads fixed with metal panel pins, including brackets for hoisting of glass complete all as specified and directed by Engr-in-charge. |
| 96 | Supply and fixing Anodised aluminium snap grid frame work for false ceiling, size of grid 605x605mm including hangers 6mm dia GI (Upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60 mm long and expension hold fasterners 12.5mm dia. 40 mm long complete all as specified and as directed by Engr-in-charge. |
| 97 | Supply and fixing Gypsum Board 600x600mm 12mm thick in ceiling fixed with screw as per manufacturers instructions, complete all as specified and directed by Engr-in-charge. |
| 98 | Dismantling/ Removing of Old brick tile / old roof treatment upto any depth, single layer on roofs complete all as specified and directed by Engr-in-charge. |
| 99 | Material and labour PCC (1;2:4) type B-1 using 20mm graded stone aggregete cement concrete in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed by Engr-in-charge. |
| 100 | Material and labour for PCC 1:2:4 type B-1, using 20mm stone aggregateas in padding average 40 mm thick to be provided in slope complete all as specified and directed by Engr-in-charge. |
| 101 | Material and labour for rendering 10mm thick in cm 1:4 mixed with WPC over concrete surfaces complete all as specified and directed by Engr-in-charge.Note:- WPC will be measured and paid separately. |
| 102 | Material and labour for preparation of roof top surfaces provinding and applying single component elastic cold applied polyurethene modified acrylic roofing system, co-elastic technology (CET) based on modified polyurethene and fully fibre reinforced, having sun reflectivity index (SIR) of 106 on top of concrete roof surface all cracks upto 3mm at corner joints, channel and parapet wall should be treated with crack seal applying three coats including onecoat of primer of shaliurethen BTD/sikalastic 560/smart care damp proof ultra having coverage@ min 0.75kg/Sqm and dilution upto 10% and laying reinforced fibre net and applying two coats of shaliurethene BTD/sikalastic 560/smart care damp proof ultra @ total comsumption 2 Kg/Sqm intwocoats for maintaining minimumdry film thickness 1.5mm and elongation at break of free film of approx 350% the material shall be applied with brush or roller complete all as specified and directed by Engr-in-charge. |
| 103 | Excavation in post holes (or similar holes) each n,exc 0.5 cum in hard/dense soil, getting out, and removing surplus soil to a distance n,exc 50 m and making good the existing surface , complete all as specified and directed by Engr-in-charge. |
| 104 | Supply and fixing in repairs chain link MS galvanised fencing any size including lines wires straining bolts including binding wires etc complete all as specified and directed by Engr-in-charge. |
| 105 | Supply and fixing MS angle iron as in posts and struts as in fencing including cutting tops to shape as directed, drilled holes notching for wire etc incl all necessary drilling, bolting or riveting etc including fixing of flat iron and horizontal bars round/tmt bars for strenthning of chain link fencing and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed by Engr-in-charge. |
| 106 | Material and labour for preparing of new steel surface of any description not otherwise described over 10cms width or girth and applying 2 coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by Engr-in-charge. |
| 107 | Taking down copper/aluminium point wiring for (light, fan , socket or power and bell) complete including unserviceable fittings such as switches, ceiling rose, holders, sockets bell etc. and making good the distrubed surfaces on wall/floor etc complete all as specified and dirceted by Engr-in-charge. |
| 108 | Taking down MCB DB TPN/SPN/ and load of any make and type inclduing dismantling all electrical connections from MCBs/MCCB/isolators and making good the distrubed surface complete all as specified and dirceted by Engr-in-charge. |
| 109 | Taking down Meter panel with with four nos single phase meter any make and type inclduing dismantling all electrical connections from meters and making good the distrubed surface complete all as specified and dirceted by Engr-in-charge. |
| 110 | Disconnecting and taking down old existing light fitting of any description from any position complete all as specified and dirceted by Engr-in-charge. |
| 111 | Disconnecting, taking up the existing electric fan and submitted to MES store yard under AGE E/M complete with all accessories complete all as specified and dirceted by Engr-in-charge. |
| 112 | Disconnecting and taking down old existing sub main wiring of any description from any position complete all as specified and dirceted by Engr-in-charge. |
| 113 | Material and Labour for Point wiring using proper colour coding complete with 1100 Volts grade 1.5 Sq.mm, single core, PVC insulated,unsheathed cable with multistranded copper conductor with ISI mark FRLS grade, conforming to IS-694 in and including PVC medium grade conduit not less than 25mm dia. ISI marked with all accessories concealed in wall/ceiling/ floor /roof etc, including GI terminal boxes with 3 mm thick plastic laminated sheet cover having necessary cutting for fixing switches/ sockets including 1.5 Sq.mm PVC insulated, unsheathed, multistranded copper conductor, FRLS 1100 volts grade (green colour) as earth wire, connected to common earth dolly for:- |
| 114 | One light point/ fan/Exhaust controlled by one switch complete all as specified and dirceted by Engr-in-charge. |
| 115 | One three pin switch socket 5 amps outlet on same board complete all as specified and dirceted by Engr-in-charge. |
| 116 | One three pin switch socket 5 amps outlet on Independent board complete all as specified and dirceted by Engr-in-charge. |
| 117 | One Bell point controlled by one switch complete all as specified and dirceted by Engr-in-charge. |
| 118 | Point wiring using proper colour coding complete all as specified with 1100 Volts grade, 2.5, Sqmm PVC insulated, FRLS, unsheathed, cable confirming to IS-694,PartII, ISI marked with Multistranded copper conductor cable in and including PVC conduit complete all as specified and dirceted by Engr-in-charge. |
| 119 | Suppy and fixing Switch piano, flush type single pole, one way 5 Amp complete all as specified and dirceted by Engr-in-charge. |
| 120 | Supply and fixing Socket outlet 3 pin, 5A, flush type complete all as specified and dirceted by Engr-in-charge. |
| 121 | Supply and fixing Switch piano, flush type single pole, one way 15 Amp complete all as specified and dirceted by Engr-in-charge. |
| 122 | Supply and fixing Bell push, flush type, 5 amp complete all as specified and dirceted by Engr-in-charge. |
| 123 | Supply and fixing Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type complete all as specified and dirceted by Engr-in-charge. |
| 124 | Supply and fixing ceiling rose surface bakelite 65x50mm with three terminals complete all as specified and dirceted by Engr-in-charge. |
| 125 | Supply and fixing stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required complete all as specified and dirceted by Engr-in-charge. |
| 126 | Supply and fixing lamp holder PVC/Polycarbonate insulated body with back plate suitable for angle/batten fitting complete all as specified and dirceted by Engr-in-charge. |
| 127 | Supply and fixing in repair Sheet metal enclosure DB SPN, 12 way with 200 Amp rated bus bar, 240 V, double door . for fixing MCB’s, isolators etc., having IP-43 protection, flush mounting, complete all as specified and dirceted by Engr-in-charge. |
| 128 | Supply and fixing in repair 240V, 10KA 'C' curve miniature circuit breaker (MCB) SPN 40 to 63 amp complete with connection testing and commissioning complete all as specified and dirceted by Engr-in-charge. |
| 129 | Supply and fixing in repair MCB,SP, 6 Amp to 32 Amp, 240 Volt, 50HZ, 10 KA, `C` Series, making electrical connection with the help of Lugs/thimbles complete all as specified and dirceted by Engr-in-charge. |
| 130 | Supply and fixing LED lights fitting 1x 20W, 220V AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and dirceted by Engr-in-charge. |
| 131 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and dirceted by Engr-in-charge. |
| 132 | Supply and fixing Buzzer, Ding Dong AC. 230 volts, single pole complete all as specified and dirceted by Engr-in-charge. |
| 133 | Supply and fixing submain wiring with 2X 10 sqmm (nominal area) PVC insulated FRLSH, unsheathed, multistrand, 1100 volts grade copper conductor cable single core. drawn through in and including non metalic PVC concealed conduit not less than 20mm dia medium grade and its accessories including one run of 10 sqmm PVC insulated copper conductor to wall with 3mm thick . Note:- surface conduit shall be laid in celing portion only. complete all as specified and dirceted by Engr-in-charge. |
| 134 | Supply and fixing submain wiring with 2X 6 sqmm (nominal area) PVC insulated FRLSH, unsheathed, multistrand, 1100 volts grade copper conductor cable single core. drawn through in and including non metalic PVC concealed conduit not less than 20mm dia medium grade and its accessories including one run of 6 sqmm PVC insulated copper conductor to wall with 3mm thick complete all as specified and dirceted by Engr-in-charge. Note:- Surface conduit shall be laid in celing portion only. |
| 135 | Supply and fixing in repair building security light fitting 25 Watt LED having power factor >0.95 THD<10% of Lux 100 Lum/watt. New generation Enrgy Saving & Environment friendly long life versatile pressure die-cast aluminium IP-66 roadway luminaries with high power LEDs as light source and electronic drive including fixing arrangment on wall with security light mounting bracket, GI pipe of suitable size medium grade for mounting bracket bent to shape upto 1.50 meter length and fixing arrangement with two Nos. of MS clamps set, nut, bolts, washers, and applying two coats of aluminium paints over & including one coat of Zinc oxide primer complete all as specified and dirceted by Engr-in-charge.Note: The GI pipe bracket is included in the unit rate quoted by the contractor |
| 136 | Supply and fixing exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, frame and louvers including making hole and making good the existing surface complete all as specified and dirceted by Engr-in-charge. |
| 137 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and dirceted by Engr-in-charge. |
| 138 | Supply and fixing electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessoriessuch as safety valve, thermostate, NRV, connection piece etc complete all as specified and dirceted by Engr-in-charge. |
| 139 | Supply and fixing Sheet metal enclosures with socket plug top and MCB , Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete for AC complete all as specified and dirceted by Engr-in-charge. |
| 140 | Material and labour in repair for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point and result should be less or equal to 1 ohm all as specified or indicated including testing on completion with electrical connection to earth test point complete all as specified and dirceted by Engr-in-charge. |
| 141 | Supply and fixing , installation, commissioning and testing CPRI approved manufactured by OEM meter panel of size (size as per approved drawing). including 4 Nos single phase energy meter .The panel should be weather and vermin proof made out of 2 mm thick CRCA sheet of suitable size with front opening ,visible of meter reading from out side and locking arrangement epoxy powder coated having colour siemens grey 200 Amps capacity Copper bus bar for phase 3 Nos and 1 No 150 amps bus bar for neutral mounted on epoxy insulator necessary copper control capacity control wiring heat shrinkable RYB coloured sleaves over bus bar for identification wall mounting angle iron base earth shields circular holes at bottom to receive incoming and outgoing cable. cable lugs, cable gland of size as required pannel suitable for the following control/filments sensible for 3 phase 50Hz 415V system complete comprising the following and including necessary PCC/Brick work for mounting of pannel. One main incomer MCCB 125 Amp 4P 16 KA Thermal/Magnetic release. Indicator provided on each phase, including four single phase sub-meters. Output supply by MCB SPN 63 Amp - 5 Nos . Five nos of MCB SPN 32 Amp provided for output supply complete all as specified and dirceted by Engr-in-charge. |
| 142 | Supply and fixing , installation, commissioning and testing CPRI approved manufactured by OEM meter panel of size (size as per approved drawing). including 5 Nos single phase energy meter .The panel should be weather and vermin proof made out of 2 mm thick CRCA sheet of suitable size with front opening ,visible of meter reading from out side and locking arrangement epoxy powder coated having colour siemens grey 200 Amps capacity Copper bus bar for phase 3 Nos and 1 No 150 amps bus bar for neutral mounted on epoxy insulator necessary copper control capacity control wiring heat shrinkable RYB coloured sleaves over bus bar for identification wall mounting angle iron base earth shields circular holes at bottom to receive incoming and outgoing cable. cable lugs, cable gland of size as required pannel suitable for the following control/filments sensible for 3 phase 50Hz 415V system complete comprising the following and including necessary PCC/Brick work for mounting of pannel. One main incomer MCCB 160 Amp 4P 16 KA Thermal/Magnetic release. Indicator provided on each phase, including four single phase sub-meters. Output supply by MCB SPN 63 Amp - 6 Nos . Six nos of MCB SPN 32 Amp provided for output supply complete all as specified and dirceted by Engr-in-charge. |
| 143 | Taking Out old unserviceable LT UG of sizes cross sectional area upto 50 sqmm Sqmm 4/3.5/2core complete all as specified and dirceted by Engr-in-charge. |
| 144 | Supply and laid in tranches/floors or fixed on wall for cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core including fixing materials like lugs,cable glands etc complete all as specified and dirceted by Engr-in-charge. |
| 145 | Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cables and getting out in soft/loose soil complete all as specified and dirceted by Engr-in-charge. |
| 146 | Returning filling in layers including leveling watering and well ramming in layers not exc. 25 cm thick complete all as specified and dirceted by Engr-in-charge. |
| 147 | Removing surplus soil to a distance not exc. 50m and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified and dirceted by Engr-in-charge. |
| 148 | Material and labour for sand cushioning with a layer of sand 8 cm thick before laying of cable and 15 cm thick (punned down to 100 mm thick) after laying of cable in trenches/ducts complete all as specified. Note: Punned down thicknes(overall 18 cm) shall be considered for measurement and payment complete all as specified and dirceted by Engr-in-charge. |
| 149 | Supplying and laying, Bricks; common burnt clay building bricks, sub-class ‘B’ designation Old size bricks complete all as specified and dirceted by Engr-in-charge. |
| 150 | Material and Labour for earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth strip 32×6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point and result should be less or equal to 1 ohm all as specified or indicated including testing on completion with electrical connection to earth test point complete all as specified and dirceted by Engr-in-charge. |
| 151 | Supply, fabricate, errect, connecting, testing, commisioning CPRI approved LT pannels cubical outdoor type weather and vermin proof made out of 3 mm thick CRCA sheet of suitable size with front and rear opening and locking arrangement epoxy powder coated having colour siemens grey 400 Amps capacity Copper bus bar for phase 3 Nos and 1 No 300 amps bus bar for neutral mounted on epoxy insulator necessary copper control capacity control wiring heat shrinkable RYB coloured sleaves over bus bar for identification floor mounting angle iron base earth shields circular holes at bottom/top to receive incoming and outgoing cable. cable lugs, cable gland of size as required pannel suitable for the following control/filments sensible for 3 phase 50Hz 415V system complete comprising the following and including necessary PCC/Brick work for mounting of pannel complete all as specified and dirceted by Engr-in-charge.(a) 4 Nos bus bar high conductivity copper strips proper insulated for phase (RYB) with 400 Amps & neutral rating 300 amps and mounting on porcelain support.- 01 Set INCOMER: 400 Amp, 4 pole MCCB, 36 KA- 01 No,Digital VAF meter with inbuilt selector switch & CT Coil - 01 NoSet of LED type indicating lamps - 01 No OUTGOINGS:Copper Bus Bar 400 Amp TPNOUTGOINGS:125 Amp, MCCB 16ka 415 V, - 2 Nos.100 Amp, MCCB 16ka 415 V, - 2 Nos.63 Amp, MCCB TPN 16ka 415 V, - 01 Nos. (spare) |
| 152 | Supply, fabricate, errect, connecting, testing, commisioning CPRI approved LT pannels cubical outdoor type weather and vermin proof made out of 3 mm thick CRCA sheet of suitable size with front and rear opening and locking arrangement epoxy powder coated having colour siemens grey 300 Amps capacity Copper bus bar for phase 3 Nos and 1 No 200 amps bus bar for neutral mounted on epoxy insulator necessary copper control capacity control wiring heat shrinkable RYB coloured sleaves over bus bar for identification floor mounting angle iron base earth shields circular holes at bottom/top to receive incoming and outgoing cable. cable lugs, cable gland of size as required pannel suitable for the following control/filments sensible for 3 phase 50Hz 415V system complete comprising the following and including necessary PCC/Brick work for mounting of pannel complete all as specified and dirceted by Engr-in-charge.(a) 4 Nos bus bar high conductivity copper strips proper insulated for phase (RYB) with 200 Amps & neutral rating 300 amps and mounting on porcelain support.- 01 Set INCOMER: 250 Amp, 4 pole MCCB, 36 KA- 01 No,Digital VAF meter with inbuilt selector switch & CT Coil - 01 NoSet of LED type indicating lamps - 01 No OUTGOINGS:Copper Bus Bar 200 Amp TPNOUTGOINGS:125 Amp, MCCB 16ka 415 V, - 2 Nos.63 Amp, MCCB TPN 16ka 415 V, - 1 Nos |
| 153 | Taking out of old unserviceable GI tubing and its connection/fittings. Complete pipe line work of size 20/25 mm bore complete all as specified and directed by Engr-in-charge. |
| 154 | Taking out of old unserviceable gate/globe valve complete with accessories from existing pipe line of size 25 mm bore complete all as specified and directed by Engr-in-charge. |
| 155 | Supply, fixing and laying galvanised iron pipe of size 25 mm dia bore medium class ISI marked including all necessary fittings through in trenches/on wall/under hardstanding path/road etc complete all as specified and directed by Engr-in-charge. |
| 156 | Supply and fixing brass gate valve/GM globe valve of size 25mm dia bore ISI marked with having iron wheel head screwed both ends complete all as specified and directed by Engr-in-charge. |
AI Tender Summary
Tender Timeline
Jul 02, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysJul 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender