Defence Statutory Bodies & Commissions/Committees Closing in 25 days TDR #56284041

Tender For Petty Repair/ Maintenance And Replacement Of High Tension Line Including Poles, Conductors, Panels, Mcbs, Mccbs And Allied Works At Sector C Under Age E/M-I Of Ge 865 Ews

Issued by Statutory Bodies & Commissions/Committees · leh, Ladakh
Tender Value
78 Lakhs
Estimated cost
Bid Submission
30 Jul 2026
25 days left
EMD
1.42 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
leh → Ladakh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Petty Repair/ Maintenance And Replacement Of High Tension Line Including Poles, Conductors, Panels, Mcbs, Mccbs And Allied Works At Sector C Under Age E/M-I Of Ge 865 Ews

BOQ

Name of Work:- PETTY REPAIR/ MAINTENANCE AND REPLACEMENT OF HIGH TENSION LINE INCLUDING POLES, CONDUCTORS, PANELS, MCBs, MCCBs AND ALLIED WORKS AT SECTOR C UNDER AGE E/M-I OF GE 865 EWS
Sl. No. Item Description
1Excavation in trenches not exc. 1.5 m wide and not exc. 1.5 m in depth and getting it out for laying of cable / pole in hard/dense soil complete all as specified and/or as directed by Engr-in-Charge.
2All as per Srl Item No 01 above, but exc. 1.5 m and not exc. 3.0 m in depth.
3Returning, filling in, including spreading, leveling watering, and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and/or as directed by Engr-in-Charge.
4Removing surplus soil to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and/or as directed by Engr-in-Charge.
5Material and labour for crushed stone sand cushioning to underground cables 8 cm below the cable before laying & 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I, complete all as specified and/or as directed by Engr-in-Charge. Note : Punned thickness only will be measured and paid for.
6Supply and laying of factory made, machine pressed, unreinforced, pre-cast concrete cable cover class HV type-1 flat size 300mm x 180mm x 50mm, complete all as specified and/ or as directed by Engr-in-Charge.
7Labour only for laying of old serviceable cable covers retrieved from excavation complete all as specified and/ or as directed by Engr-in-Charge.
8Supply and fix in replacement GI Pipe Light grade of size 100mm dia with all connected accessories for passing/ crossing of cable in road/ path/ culvert/ wall etc. complete all as specified and/ or as directed by Engr-in-Charge.
9Cutting of existing road not exc. 1.5 mtr in depth and not exc.1.5 mtr wide including black top, sub base and WBM, well ramming in layers with watering after laying of RCC /GI pipe under road making good surafce in all respect to match with the existing surface complete all as specified and/ or as directed by Engr-in-Charge.
10Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts grade with stranded aluminium conductor of size 95 sqmm 3 core including taking down old unserviceable cable complete all as specified and/ or as directed by Engr-in-Charge.
11Supply, jointing and testing in repairs cable end termination joint kit outdoor type (heat shrinkable) suitable for XLPE aluminium conductor cable of size 50 to 95 Sqmm 3 Core, 11000 Volts grade, complete all as specified and/or as directed by Engr-in-Charge. Make: Denson/ 3M/ M Seal
12Supply, jointing and testing in repairs cable end termination joint kit indoor type (heat shrinkable) suitable for XLPE aluminium conductor cable of size 50 to 95 Sqmm 3 Core, 11000 Volts grade, complete all as specified and/or as directed by Engr-in-Charge. Make: Denson/ 3M/ M Seal
13Supply, jointing and testing in repairs straight through joint kit outdoor type (heat shrinkable) suitable for XLPE aluminium conductor cable of size 50 to 95 Sqmm 3 Core, 11000 Volts grade, complete all as specified and/or as directed by Engr-in-Charge.Make: Denson/ 3M/ M Seal
14Supply and fix in replacement of indicating lamps for cubical panel complete all as specified and/or as directed by Engr-in-Charge.
15Supply and fix in replacement of digital voltmeter of 0 to 500 Volts complete all as specified and/or as directed by Engr-in-Charge. Make : DIP / AE / IMP
16Supply and fix in replacement digital Ammeter 0 to 500 Amps of size 135mm x 135mm, complete all as specified and/or as directed by Engr-in-Charge. Make : DIP / AE / IMP
17Supply and fix in replacement digital Ammeter 0 to 250 Amps of size 135mmx135mm, complete all as specified and/or as directed by Engr-in-Charge. Make : DIP / AE / IMP
18Material and labour for Dehydration, filtration of transformer oil from transformer of capacity upto 630 KVA to remove moisture, sludge, carbon particles and to achieve dielectric strength/rupturing capacity of oil and topping up of oil to the required level of the transformer indicator level complete all as specified and/or as directed by Engr-in-Charge.Note: (a) Oil topping up shall be measured and paid separately.(b) Filtration shall be done at site and on line.(c) BDV test shall be carried out before the filtration and after the filtration & results recorded in triplicate duly signed by the contractor, MES rep. and Engr-in-charge.(d) Dielectric strength of the oil shall not be less than 60 kV after filtration. (e) The rate quoted for the item is deemed to include the filtration till the desired dielectric strength is achieved.
19Supply and filling of new transformer oil, topping up / change complete of superior quality having di-electric strength not less than 65 KV and ISI marked of approved make complete all as specified and/or as directed by Engr-in-Charge.Note: (a) The transformer oil shall be ISI marked and brought at site in sealed container only.(b) Cost of collection of samples before and after topping up/ changing including testing for dielectric strength etc. complete included in the rate quoted for this item. Please Enable Macros to View BoQ information
20Supply and filling of new transformer oil, topping up / change complete of superior quality having di-electric strength not less than 65 KV and ISI marked of approved make complete all as specified and/or as directed by Engr-in-Charge.Note: (a) The transformer oil shall be ISI marked and brought at site in sealed container only.(b) Cost of collection of samples before and after topping up/ changing including testing for dielectric strength etc. complete included in the rate quoted for this item. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56284041
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 78 Lakhs
LAST DATE 30-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Petty Repair/ Maintenance And Replacement Of High Tension Line Including Poles, Conductors, Panels, Mcbs, Mccbs And Allied Works At Sector C Under Age E/M-I Of Ge 865 Ews
Basic Detail
Tender No 138WE/L-51/2026-27
Bidding Type Tender
Location
City leh
State Ladakh
Key Dates
Publish Date 02 Jul 2026
Submission Date 30 Jul 2026
Open Date 06 Aug 2026
Finance
Tender Value 78 Lakhs
Tender Fee 1000
EMD 1.42 Lakhs
Exemption Available
Document List
71501d05-b248-4c20-8d38-9a3209c261f8.html
BOQ_868741.xls
TenderL512627.pdf
Tendernotice_1 (1).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 02, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 25 days
Aug 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 32 days

Tender Documents

Download All (ZIP) ↓
html

71501d05-b248-4c20-8d38-9a3209c261f8.html

xls

BOQ_868741.xls

pdf

TenderL512627.pdf

pdf

Tendernotice_1 (1).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders