Tender For Petty Repair/ Maintenance And Replacement Of High Tension Line Including Poles, Conductors, Panels, Mcbs, Mccbs And Allied Works At Sector C Under Age E/M-I Of Ge 865 Ews
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exc. 1.5 m wide and not exc. 1.5 m in depth and getting it out for laying of cable / pole in hard/dense soil complete all as specified and/or as directed by Engr-in-Charge. |
| 2 | All as per Srl Item No 01 above, but exc. 1.5 m and not exc. 3.0 m in depth. |
| 3 | Returning, filling in, including spreading, leveling watering, and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and/or as directed by Engr-in-Charge. |
| 4 | Removing surplus soil to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and/or as directed by Engr-in-Charge. |
| 5 | Material and labour for crushed stone sand cushioning to underground cables 8 cm below the cable before laying & 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I, complete all as specified and/or as directed by Engr-in-Charge. Note : Punned thickness only will be measured and paid for. |
| 6 | Supply and laying of factory made, machine pressed, unreinforced, pre-cast concrete cable cover class HV type-1 flat size 300mm x 180mm x 50mm, complete all as specified and/ or as directed by Engr-in-Charge. |
| 7 | Labour only for laying of old serviceable cable covers retrieved from excavation complete all as specified and/ or as directed by Engr-in-Charge. |
| 8 | Supply and fix in replacement GI Pipe Light grade of size 100mm dia with all connected accessories for passing/ crossing of cable in road/ path/ culvert/ wall etc. complete all as specified and/ or as directed by Engr-in-Charge. |
| 9 | Cutting of existing road not exc. 1.5 mtr in depth and not exc.1.5 mtr wide including black top, sub base and WBM, well ramming in layers with watering after laying of RCC /GI pipe under road making good surafce in all respect to match with the existing surface complete all as specified and/ or as directed by Engr-in-Charge. |
| 10 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts grade with stranded aluminium conductor of size 95 sqmm 3 core including taking down old unserviceable cable complete all as specified and/ or as directed by Engr-in-Charge. |
| 11 | Supply, jointing and testing in repairs cable end termination joint kit outdoor type (heat shrinkable) suitable for XLPE aluminium conductor cable of size 50 to 95 Sqmm 3 Core, 11000 Volts grade, complete all as specified and/or as directed by Engr-in-Charge. Make: Denson/ 3M/ M Seal |
| 12 | Supply, jointing and testing in repairs cable end termination joint kit indoor type (heat shrinkable) suitable for XLPE aluminium conductor cable of size 50 to 95 Sqmm 3 Core, 11000 Volts grade, complete all as specified and/or as directed by Engr-in-Charge. Make: Denson/ 3M/ M Seal |
| 13 | Supply, jointing and testing in repairs straight through joint kit outdoor type (heat shrinkable) suitable for XLPE aluminium conductor cable of size 50 to 95 Sqmm 3 Core, 11000 Volts grade, complete all as specified and/or as directed by Engr-in-Charge.Make: Denson/ 3M/ M Seal |
| 14 | Supply and fix in replacement of indicating lamps for cubical panel complete all as specified and/or as directed by Engr-in-Charge. |
| 15 | Supply and fix in replacement of digital voltmeter of 0 to 500 Volts complete all as specified and/or as directed by Engr-in-Charge. Make : DIP / AE / IMP |
| 16 | Supply and fix in replacement digital Ammeter 0 to 500 Amps of size 135mm x 135mm, complete all as specified and/or as directed by Engr-in-Charge. Make : DIP / AE / IMP |
| 17 | Supply and fix in replacement digital Ammeter 0 to 250 Amps of size 135mmx135mm, complete all as specified and/or as directed by Engr-in-Charge. Make : DIP / AE / IMP |
| 18 | Material and labour for Dehydration, filtration of transformer oil from transformer of capacity upto 630 KVA to remove moisture, sludge, carbon particles and to achieve dielectric strength/rupturing capacity of oil and topping up of oil to the required level of the transformer indicator level complete all as specified and/or as directed by Engr-in-Charge.Note: (a) Oil topping up shall be measured and paid separately.(b) Filtration shall be done at site and on line.(c) BDV test shall be carried out before the filtration and after the filtration & results recorded in triplicate duly signed by the contractor, MES rep. and Engr-in-charge.(d) Dielectric strength of the oil shall not be less than 60 kV after filtration. (e) The rate quoted for the item is deemed to include the filtration till the desired dielectric strength is achieved. |
| 19 | Supply and filling of new transformer oil, topping up / change complete of superior quality having di-electric strength not less than 65 KV and ISI marked of approved make complete all as specified and/or as directed by Engr-in-Charge.Note: (a) The transformer oil shall be ISI marked and brought at site in sealed container only.(b) Cost of collection of samples before and after topping up/ changing including testing for dielectric strength etc. complete included in the rate quoted for this item. Please Enable Macros to View BoQ information |
| 20 | Supply and filling of new transformer oil, topping up / change complete of superior quality having di-electric strength not less than 65 KV and ISI marked of approved make complete all as specified and/or as directed by Engr-in-Charge.Note: (a) The transformer oil shall be ISI marked and brought at site in sealed container only.(b) Cost of collection of samples before and after topping up/ changing including testing for dielectric strength etc. complete included in the rate quoted for this item. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 02, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 25 daysAug 06, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 32 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender