Tender For Installation Of Electrical Wiring Along With Other Electrical Installations At Ground & First Floor Of Newly Renovated Kmcp School At 15, Devi Chowdhury Road In Ward No.79 Under Br-Ix.
Tender Value
7.72 Lakhs
Estimated cost
Bid Submission
18 Jul 2026
6 days left
EMD
16000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Installation Of Electrical Wiring Along With Other Electrical Installations At Ground & First Floor Of Newly Renovated Kmcp School At 15, Devi Chowdhury Road In Ward No.79 Under Br-Ix.
BOQ
| Sl. No. | Item Description |
| 1 | A N N E X U R E - I Basic Rate of Materials: (All Rates of materials from K-1 to K-14 are excluding VAT) 32. CFL luminaire (Havells make-LHRC4185099) Out door type |
| 2 | Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener |
| 3 | A N N E X U R E - I Basic Rate of Materials: (All Rates of materials from K-1 to K-14 are excluding VAT) 29. Bulk head light fitting (Havells Make) |
| 4 | Supply and delivery of 1200 mm sweep, 1 phase, 60/70 watt, 5 star and having 300 mm down rod, 1.1mm thick alluminium bled, conforming IS 374, 2mm shank thickness ceilling fan of following make. Havells/Crompton Greaves Make (60 watt): |
| 5 | A N N E X U R E - I Basic Rate of Materials: (All Rates of materials from K-1 to K-14 are excluding VAT)107. Modular Soket type 2 module regulator |
| 6 | Fixing only ceiling fan complete with blades, canopy, FORk, rubber bush etc. incl. S&F connecting wire FOR down rod upto 30 cm incl. painting the rod with(approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. |
| 7 | Supply and delivery of 230V,50Hz Heavy duty Metal 9\\"exhuast fan. |
| 8 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection FOR exhaust of 23 cm (9\\"): diameter |
| 9 | Wiring With PVC Insulated & Unsheathed Single Core Stranded Copper Wire `'FR' ... in PVC Casing-capping (Precision Make) on wall/ceiling with Modular type Switch Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire brand(approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire FOR ECC, incl. necy. fittings etc. to light/fan/call bell point with Modular type switch brand(approved by EIC) fixed on Modular GI / PVC switch board with top cover plate on wall incl. mending good damages to original finish. [PVC casingcapping and Switch board both on surface] Average run 9 mtr |
| 10 | Distribution Wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire brand(approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire FOR ECC, incl. necy. fittings etc. with S & F 6A 5 pin Modular type plug socket and switch brand(approved by EIC) fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. necy. connection making earthing attachment, painting and mending good damages to building works [PVC casing-capping on surface and Switch board concealed] On Board |
| 11 | Wiring With PVC Insulated & Unsheathed Single Core Stranded Copper Wire `'FR' ... in PVC Casing-Capping (Precision Make) on wall/ceiling.Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand(approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire FOR ECC, incl. necy. PVC clips, fittings etc. to light/fan/call bell point with piano key type switch (Anchor make) fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works [PVC casing-capping on surface and Switch board concealed) Average run 9 mtr |
| 12 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket brand(approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 13 | Wiring With PVC Insulated & Unsheathed Single Core Stranded Copper Wire `'FR' ... in PVC Casing-Capping (Precision Make) on wall/ceiling.Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand(approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc. 2 x 56/0.3 (4 sqmm) + 1 x 22/0.3 (1.5 sqmm) |
| 14 | Wiring With PVC Insulated & Unsheathed Single Core Stranded Copper Wire `'FR' ... in PVC Casing-Capping (Precision Make) on wall/ceiling.Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand(approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc. 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) |
| 15 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand(approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC |
| 16 | Wiring With PVC Insulated & Unsheathed Single Core Stranded Copper Wire `'FR' ... in PVC Rigid Conduit 'FR' (iSI Marked) on wall/ceiling Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire brand(approved by EIC) in 20mm size PVC rigid conduit 'FR'(Precision make) incl. necy. fittings as required 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC |
| 17 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision FOR earthing attachment .Legrand 2+12 way Enclosure (607712) |
| 18 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand 63 A DP |
| 19 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand 40 A DP |
| 20 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand 6-32 A DP |
| 21 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand 6-32 A SP |
| 22 | (H) Street lights :2. Distribution wiring FOR steel light on pole FOR outdoor fluorescent/SV/MV light fitting with 2x1/1.40 PVC insulated and sheathed wire (single core) in 15 mm dia GI Pipe (ISI Medium), without control switch, incl. fitting and fixing the light fitting by providing 32 mm dia GI Pipe bracket of lengh 1.05 mts, on pole incl. S&F sutable MS flat clamps with bolts, nuts etc. as required and painting |
| 23 | Supplying Al.conductor PVC insulated and sheathed unarmoredcable (1.1KVgrade, Gloster/Havells/Polycab).10sqmm x 4core |
| 24 | Laying on Pole with Clamps.Fixing of Cable along the lentgh of O.H. pole incl. S & F MS pole clamps fabricated from 25 mm x 6 mm MS flat incl. painting |
| 25 | Fixing only fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit, ball socket/socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length. |
| 26 | Supply and Fixing of 2 mm Polyvinyl glow sign board made of 22 SWG GI sheet box with 1...X1... aluminum channel for fixing the vinyl board after necessary cutting the letter as required & s\f LED tube light fittings along with all accessories |
| 27 | Supply, and fixing of 2 HP Centrifugal Monoblock pump Make- KSB, AGRIBLOC 20-5050 |
| 28 | SCHEDULE OF RATES FOR EARTHING INSTALLATIONS.Earthing Installation by GI pipe ... (FOR Sub(station Neutral/Equipment earthing).Earthing with 65 mm dia GI pipe (TATA(Medium)x 3.0 Mts. long and 1 No. 50 mm x 6 mm galvanized (HOT Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 65 mm dia GI pipe (ISI Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts |
| 29 | SCHEDULE OF RATES FOR OVERHEAD LINE INSTALLATION - REPAIR 14. Dismantling steel tubular/Rail/Strut embedded in CC foundation incl. excavation, filling of holes, restoring surface,loading at site and delivering, unloading, sorting, stacking properly at any place as per direction upto a lead of 1.6 km |
| 30 | SUPPLYING OF APPROVED MAKE PEDESTAL FAN OSCILLATING TYPE WITH BASE,BLADES,GUARD,SPEED REGULATOR ETC. AC230-250 VOLTS. 500MM SWEEP, SCHEDULE IRRIGATION 2022 |
| 31 | SUPPLY & DELIVERY OF 120 WATT LED STREET LIGHT FITTING |
| 32 | Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision FOR two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision FOR earthing attachment 2 Way |
| 33 | A N N E X U R E - I Basic Rate of Materials: (All Rates of materials from K-1 to K-14 are excluding VAT) 89. 6 module GI box |
| 34 | A N N E X U R E - I Basic Rate of Materials: (All Rates of materials from K-1 to K-14 are excluding VAT) 96. 6 module Cover plate |
| 35 | Sub Total |
| 36 | GST 18% |
| 37 | CESS 1% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 18, 2026
17:00 IST