Public Administrative Department Local Bodies Closing in 7 days TDR #56283412

Tender For Repair Works, Supplying And Fixing Items For Member Of Legislative Assembly,Tiruvottriyur Constitution Office Room At Zonal C Us, T.H Road, In Division-11, Unit-03, Zone-01.

Issued by Local Bodies · Thiruvallur, Tamil Nadu
Tender Value
8.16 Lakhs
Estimated cost
Bid Submission
17 Jul 2026
7 days left
EMD
8160
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvallur → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair Works, Supplying And Fixing Items For Member Of Legislative Assembly,Tiruvottriyur Constitution Office Room At Zonal C Us, T.H Road, In Division-11, Unit-03, Zone-01.

BOQ

Name of Work:- Repair works, Supplying and Fixing items for MEMBER Of LEGISLATIVE ASSEMBLY,Tiruvottriyur Constitution Office Room at Zonal C us, T.H Road, in Division-11, Unit-03, Zone-01.
Sl. No. Item Description
1Supplying, fabricating, erecting and fixing Calcium Silicate Board False Ceiling upto a ceiling height of 4.5m from floor level - Using Calcium Silicate Board Plain Sheets (10mm thick)
2Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used , hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
3Painting Old Plastered Wall Surface with Two finishing coats of ready mixed (Emulsion) of approved quality and colour over the existing wall in all floors etc., complete complying with standard specificationand as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
4Painting Old iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with Two coats of best approved first quality and colour of synthetic enamel paint in all floors etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
5Synthetic Enamel Paint for Wood Work
6Providing and Fixing of polyurethane foam as Internal Partition Wall Thermal insulation panels or Sandwich insulated panels wihboth internal and external 0.50mm total coated thickness repainted galvanized iron sheet with micro ribbed profile and the insulation material will be chlorofluoro carbon and hydro chlorofluoro carbon free , high performance rigid polyurethane foam (PUF) conforming to IS 12436 having density not less than 40±2Kg/M3, Thermal conductivity (K-Value) 0.024 W/m.K measured at 10 degree C mean temperature along with necessary flashings such as L flashing, C flashing etc& accessories such as screws, fastners, sealants etc for fixing the panel etc., complete complying with standard specification. - 150mm thick PUF Internal Partition wall panel
7Providing UPVC (Un- Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals.Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug.
8Bamboo reepers
9Special Pendant Lights for Multipurpose Rooms - Kite: ID KL7345 or equivalent, CYLIN, Surface mounting, integral with 15W LED. Dimension: 110mmØ x 120mm. IP22. Colour : White with silver reflector.
10Signage Board for entrance - 3mm SS 10\\" Letters with LED Lighting with Inclusive of Materials, Labour and Trasportation.
11Supplying Providing and Fixing Dining Table & Seater made up of stainless steel (SS 304 grade) etc complete complying with standard specification and as directed by the departmental – officers
12Desktop computer Intel Core i7 Processor, 8 GB RAM,512 GB SSD, Windows 11,14th Gen, key board, mouse with 21 inch Screen
13Supply, fabrication and fixing of MS Channel for Mounting the Airconditioning Indoor Unit
14Supply, fabrication and fixing of MS Channel for Mounting the Airconditioning Oudoor Unit
15Providing Cup-board Shutter with frame using termite / water proof plywood of 19mm thick over which laminated sheet of 0.8mm thick fixed inside the shutter and 1mm thick fixed in the outside of the shutter using adhesive along with necessary furniture fittings, such as, hydralic hinges, tower bolt, handles, multi purpose locks etc., as directed by the Departmental Officers. The design pattern, water proof plywood, laminate sheet and other materials should be got approved from the Executive Engineer befoe use on work. Solid PVC Door Shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC Sheets. Shutter using 5mm thick solid PVC Sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm with suitable rabate for housing the shutter
16Solid Core Flush shutters with commercial ply on both side with teakwook lipping alround 35mm thick
17Dismantling - Pressed Tiles & Weathering Course
18Providing and laying in position, standardised concrete Mix M-20 Grade using In-situ Concrete batching plant/ Ready Mix Concrete (RMC) adopting weigh batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 1012mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including Conveyance of concrete from batching plant to Work site, Electricity charges and other works & labour cost involved for concrete production, laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess
19Terrace waterproofing a. Surface Preparation - Cleaning the surface properly and attending the cracks on surface wherever required with polymer modified mortar in CM 1:4 admixed with SBR Latex or equivalent at 2 kg per bag of cement. Prepond water test to be done for 48 hours to check for any leakage and if required pressure grouting to be done to arrest leakage. b. Treatment of pipe outlet/drain using twin sided adhesive tape to the Periphery of the Pipe Outlet and filling the same with expansive cementitious grout/ micro concrete. a. c. Providing and applying one coat of PU Primer /Moisture Insensitive Epoxy primer @ 5 - 6 Sqm/kg shall be applied on the entire surface, Followed by Providing and applying \\" Solvent based, liquid applied, high permanently elastic, single component, elastomeric, seamless, moisture curing, waterproof membrane, applied in 2 coats with roller / airless spray, at a total consumption of minimum 2 - 2.20 kg/ Sqm, to achieve an avg.system DFT of 1.50 mm, having the following properties 1.Elongation at break - 400% as per ASTM D 412 / DIN 52455 2.Tensile strength of > 2.00Mpa as per ASTM D 412 / DIN52455 3.Adhesion to concrete surface over 2.0 N/mm2 as per ASTMD7234 4.Shore A Hardness of 75 as per ASTM D 2240 (15”) 5.Fire resistance EURO Class-F 6.Resistant to plant roots as per EN 13948 7. Service temperature range of -40deg C to 80deg C8. Solids content of around 90%
20Providing and laying of first quality of Johnson Endura or equivalent brand of Cool Roof plain white vitrified tile with Solar Reflective Index (SRI) Value >90 in 300x300mm size (minimum thickness shall be 8.0mm) with water absorption less than 0.5% and confirming to IS :15622:2017,of approved make , laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.
21Supplying & Installing CURTAIN BLINDS withSunscreen perforated Roller blind optima series Basket125 Tex with fabric specification of (Fabric compositition polyster 22% and PVC78%, Openenss Factor-5%, Thickness - 0.68MM +/-5%, weight per m2 -480 GSM, yarns count in wrap/ weft/cm 19/18+/-5%, Fire Resistance-FR(USA) KFI(Korea), Tear Resistance- wrap11.9 daN+/- 5%,WEFT 150 daN+/-5%,colour fastness-6-7/8 (white colour base), artificial llight xenon lamp, UV resistance Min3(White colour base), width 2.5M & 3 M. The Roller mechanism shall be a moulded unit made from engineering grade plastic polymer with PVC spring support. The Fabric shall be attached to the roller tubewith high quality self adhesive tape with manual operation.The fabric shall be attached to the tube with adhesive strip. It should have minimum one ton fabric which must be placed on the roller before the working section of fabric start Operational action shall be smooth including necessary hardware for fixing at all places & as directed by Engineer-in-charge etc complete. The rate is inclusive of laying, conveyane, all other Tools and Plants involved in the work charges and all other incidental charges etc. complete and as directed by the departmental officer (The materials quality, brand, colour, shade should Be approved by the Executive Engineer before use on works).
221.5 TR Split Type AC Unit - 3 Star Rated
23Earthing as per PWD standard with an earth electrode of 2 metre Class B GI pipe of dia not less than 32mm complete with necessary masonry work
24Supply of Monkey Dustbin FRP – 2 Layers to a height of 3½ and width of 2½
25Supplying for Steel Bero
26Supplying for Chairs
27Supplying for Computer table
28Executive Table
29Executive Chairs
30Supplying for VIP Executive Chairs Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56283412
AUTHORITY Local Bodies
TENDER VALUE 8.16 Lakhs
LAST DATE 17-07-2026
Authority
Authority Name Corporation Of Chennai
Work Description Tender for Repair Works, Supplying And Fixing Items For Member Of Legislative Assembly,Tiruvottriyur Constitution Office Room At Zonal C Us, T.H Road, In Division-11, Unit-03, Zone-01.
Basic Detail
Tender No Z.O.1.C.No.B2/1854/2026
Bidding Type Tender
Location
City Thiruvallur
State Tamil Nadu
Key Dates
Publish Date 03 Jul 2026
Submission Date 17 Jul 2026
Open Date 17 Jul 2026
Finance
Tender Value 8.16 Lakhs
Tender Fee Ref. Documents
EMD 8160
Exemption Not Available
Document List
1854.pdf
bcab89aa-6ec6-4a42-acb2-3448c88037ce.html
BOQ_821946.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Jul 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
pdf

1854.pdf

html

bcab89aa-6ec6-4a42-acb2-3448c88037ce.html

xls

BOQ_821946.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders