Tender For Laying Of Distribution Main In Leftout Areas At Nagapattinam Municipality.
Tender Value
3.35 Crore
Estimated cost
Bid Submission
15 Jul 2026
0 days left
EMD
3.35 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nagapattinam → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Laying Of Distribution Main In Leftout Areas At Nagapattinam Municipality.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches having bed width 1.25m & below for laying of pipes for water supply and sewerage works in the following type of soils as directed by Departmental officers. Sand, silt or other loose soil, wet sand or silt not under water light black cotton soil, sandy loam andordinary soil.SS20B Pg No.211 Vol-II |
| 2 | 315 mm dia HDPE PN 6 |
| 3 | 250 mm dia HDPE PN 6 |
| 4 | 160 mm dia HDPE PN 6 |
| 5 | 140 mm dia HDPE PN 6 |
| 6 | 110 mm dia HDPE PN 6 |
| 7 | Supply & delivery of following sizes of HDPE PIPES and DI PIPES confirming to IS 4984/2016 TWAD SOR Pg No.14 |
| 8 | 315 mm dia HDPE PN 6 |
| 9 | 250 mm dia HDPE PN 6 |
| 10 | 160 mm dia HDPE PN 6 |
| 11 | 140 mm dia HDPE PN 6 |
| 12 | 110 mm dia HDPE PN 6 |
| 13 | Lowering HDPE pipes and specials to trench and laying to proper grade and alignment and as directed by the Department Officers TWAD SOR Pg No.192 Vol- II |
| 14 | 315 mm dia HDPE PN 6 |
| 15 | 250 mm dia HDPE PN 6 |
| 16 | 160 mm dia HDPE PN 6 |
| 17 | 140 mm dia HDPE PN 6 |
| 18 | 110 mm dia HDPE PN 6 |
| 19 | Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by Department Officers. TWAD SOR Pg No.204 Vol- II |
| 20 | 315 mm dia HDPE PN 6 |
| 21 | 250 mm dia HDPE PN 6 |
| 22 | 160 mm dia HDPE PN 6 |
| 23 | 140 mm dia HDPE PN 6 |
| 24 | 110 mm dia HDPE PN 6 |
| 25 | Supply , delivery and fixing of HDPE Pipe specials as per IS 8360/1977/Part I at site etc., complete as directed by Engineer in charge. TWAD SOR Pg No.20 |
| 26 | CROSS |
| 27 | 315 mm dia HDPE PN 6 |
| 28 | 250 mm dia HDPE PN 6 |
| 29 | 160 mm dia HDPE PN 6 |
| 30 | 140 mm dia HDPE PN 6 |
| 31 | 110 mm dia HDPE PN 6 |
| 32 | 315 mm dia HDPE PN 6 |
| 33 | 250 mm dia HDPE PN 6 |
| 34 | 160 mm dia HDPE PN 6 |
| 35 | 140 mm dia HDPE PN 6 |
| 36 | 110 mm dia HDPE PN 6 |
| 37 | 315 mm dia HDPE PN 6 |
| 38 | 250 mm dia HDPE PN 6 |
| 39 | 160 mm dia HDPE PN 6 |
| 40 | 140 mm dia HDPE PN 6 |
| 41 | 110 mm dia HDPE PN 6 |
| 42 | END CAP |
| 43 | 315 mm dia HDPE PN 6 |
| 44 | 250 mm dia HDPE PN 6 |
| 45 | 160 mm dia HDPE PN 6 |
| 46 | 140 mm dia HDPE PN 6 |
| 47 | 110 mm dia HDPE PN 6 |
| 48 | Barricading work (Where the lines are in narrow width of municipality area, busy streets like Market, Bus-stand and in the Highways etc.) for laying of pipe line using and finally removing and stacking the materials safely for further use etc., complete and as directed by Department officers.TWAD SOR Pg No.209 |
| 49 | Refilling the trenches with excavated earth (other than sand) in layers and watering, ramming and consolidation as per standard specification etc complete and as directed by Engineer in charge. TWAD SOR Pg No.211 |
| 50 | 315 mm dia HDPE PN 6 |
| 51 | 250 mm dia HDPE PN 6 |
| 52 | 160 mm dia HDPE PN 6 |
| 53 | 140 mm dia HDPE PN 6 |
| 54 | 110 mm dia HDPE PN 6 |
| 55 | Labour charges for cutting of B.T road or WBM roads forlaying of mains and as directed by Engineer in charge. Pg No.215 Vol - II |
| 56 | C.C Road |
| 57 | B.T Road |
| 58 | Supply delivery to site, fixing & Commissioning of CI Sluice valve to pressure rating PN 1.6 for isolation confirming to IS 14846/2000 with necessary rubber insertions, bolts & nuts including loading transporting charges taxes & duties etc complete at site as per standard specification and as directed by engineers of following sizes TWAD SOR Pg No.71 Vol-II |
| 59 | 100 mm Dia |
| 60 | 150 mm Dia |
| 61 | 200 mm Dia |
| 62 | 250 mm Dia |
| 63 | Construction of chamber for sluice valve & Scour valve using second class chamber bricks in cement mortar 1:4 and necessary plastering with cement mortar 1:3 for 12 mm both inside and outside, precast concrete covers as per drawing, as per IS specifications and as directed by the engineers for the following sizes in meters as per drawings |
| 64 | Valve Pit size – 1.2 m x 0.9 m |
| 65 | Valve Pit size – 1.5 m x 1.2 m Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodayJul 15, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
TodayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender