Housing Urban and Rular Development Local Bodies Closing in 0 days TDR #56283205

Tender For maintenance of Completed Scheme Under Nazul Account-Ii, Horticulture Zone.Sh : A) Supplying, Repairing, Installation, Testing & Commissioning And repair maintenance Of Water Fountain With Multicolour Rgb Led Lights, B) Augmentation Of 4 Me

Issued by Local Bodies · Delhi, Delhi
Tender Value
28.52 Lakhs
Estimated cost
Bid Submission
09 Jul 2026
0 days left
EMD
57051
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for maintenance of Completed Scheme Under Nazul Account-Ii, Horticulture Zone.Sh : A) Supplying, Repairing, Installation, Testing & Commissioning And repair maintenance Of Water Fountain With Multicolour Rgb Led Lights, B) Augmentation Of 4 Meter Gi Pole Along With 45-Watt Led Street Light Fittings, Gate Light, Cable Etc. At Hathoda Ram Park Under Hd-2, Horticulture Zone.

BOQ

Name of Work:- M/o Completed Scheme under Nazul Account-II, Horticulture Zone.SH : A) Supplying, Repairing, installation, testing & commissioning and RMO of Water Fountain with Multicolour RGB LED Lights, B) Augmentation of 4 Meter GI Pole along with 45-Watt LED Street Light Fittings, Gate Light, Cable etc. at Hathoda Ram Park under HD-2, Horticulture Zone.
Sl. No. Item Description
1SITC of Three Phase Open well ISI marked Submersible Pump Set of 7.5 HP capacity suitable for operation on 415V(+10%), 3-Phase AC supply compatible for operations on dynamic variable frequency/speed having IP 68 Protection including providing required no's of heavy duty MS clamps made of flat iron and suitable size top cover made of suitable thick MS sheet as required. and making of flexible IP68 cable connections etc. complete as required.
2SITC of Single Jet Crown Nozzles complete with ball joint for 15 Degree Pivoting made of Brass with Nickle Plating, flow straightner in following size. Height of water stream up to 10 mtrs. etc. complete as required.15 mm internal threaded with 6 mm orfice.
340 mm internal threaded with 17 mm orfice.
4Supplying and fixing of following size of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
5SITC of fixing of following dia. Gun Metal Gate Valve (Screwed type) on the existing pipeline, including testing & commissioning etc. complete as required.50 mm dia.
6SITC of fixing of following dia. Gun Metal Horizontal Non-Return valve (Screwed type) on the existing pipeline, including testing & commissioning etc. complete as required.100 mm dia.
7SITC of underwater Luminaries surface mounted RGB LED Spot Light 6 x 3W with IP 68 protection, SS/aluminium dia. casting body with power coated paint, soft rubber gasket along with 2 years free replacement guaranty etc. complete as required.
8Supplying & fixing PVC insulated PVC sheathed copper conductor Submersible Flat cable ISI marked in existing metal/HDPE/PVC/Pipe/in Bore well/in Sump including fixing the cable to GI/HDPE pipe with suitable cable tags of following sizes etc. complete as required.3 Core 2.5 Sq mm Flat Cable
93 Core 6 Sq mm Flat Cable
10SITC of 2.00 Mtr. x 2.00 Mtr. Square shaped in 50 mm dia. Pipe size Stainless Steel 304 Grade having provision with 48 Nos. 15 mm dia. sockets and 50 mm dia. 2 Nos. etc. complete as required.
11SITC of adjustable Stainless Steel Stand (SS-304) for LED Lights 6 x 3 Watt & 12 x 3 Watt with all accessories including nuts, bolts etc. complete as required.
12Excavation and cleaning of malba from existing pit in fountain body with the help of labour and making it suitable for water filling i/c water proofing and repair of fountain body.
13Supplying and Laying of PVC Insulated and FRLS Multi Core Round Sheathed Bright Annealed Bare Copper Conductor Heavy Duty Industrial Cables for Voltage Grade up to 1100 Volts as per IS: 694:2010 etc. complete as required.4C x 2.5 sq. mm
14SITC of UPVC Pipes of confirming to IS 4985:2000 including all UPVC fitting i/c jointing with good quality solvent of following sizes etc. complete as required.110 mm OD Pipe for Delivery Lines
1563 mm OD Pipe for Delivery Lines
1650 mm OD Pipe for Delivery Lines
1732 mm OD Pipe for Delivery Lines
18SITC of floor mounted LT Feeder Pillar cubical type double door of size 900 (H) mm x 900 mm (W) x 300 mm (D) with general arrangement made out of 2 mm thick MS CRCA Sheet having hinged gasket covers and screwed knobs with double locking arrangement & Locking Hooks and separate Rain Protection Cover with extension of 100 mm in Width & Depth, supported with MS Angle Iron legs and bottom frame of size 40 mm x 40 mm x 6 mm x 1 mtr. long grouted with 1:3:6 CC foundation and should be 0.7 mtr. above ground level. Legs (around 25% of length OR as per direction of AE(E)-in-Charge) should be covered with brick walls, duly 1:4 cement plaster, connections, inter connections with suitable size of FRLS PVC insulated copper conductor using thimbles, ferrules wherever required, Painting with Primer, Numbering, Identification Plate of Component embossed and/or printed in Metal including Supply & Fixing of following accessories etc. complete as required (as per drawing approved by Engineer-in-Charge).(For 7.5 HP Pump-1 No. and 1.5 HP Filtration and Drain Pump-1 No.)a) 100 A, 30 kA Ics=100% Icu and Operational Voltage 690 V, 4 Pole MCCB- 1 No. (Incomer).b) 6 A to 32 A ratings, SP MCB, “C” curve, 10 KA breaking capacity- 2 Nos.c) 6 A to 32 A ratings, DP MCB, “C” curve, 10 KA breaking capacity- 4 Nos.d) 6 A to 32 A ratings, TPN MCB, “C” curve, 10 KA breaking capacity- 2 Nos.e) Single Phase Preventor VSP2- 2 Nos.f) Volt Selector Switch- 1 No.g) Ammeter (0-100 A) 96 sq. mm in size and 100/5 CT’s Ratio- 2 Set.h) Voltmeter (0-500 V) 96 sq. mm in size with Selector Switch- 1 Set.i) Auxiliary Contactor Block- 1NO- 2 Nos.j) Auxiliary Contactor Block- 1NC- 2 Nos.k) Overload Relay 7.5-10 Amp- 2 Nos.l) TPN Power Contractors MNX-9- 2 Nos.m) Digital Time Switch- 2 Nos.n) Start/Stop Push Button Assembly- 2 Nos.o) Indication Lamp (RYB) with Control HRC Fuse with Fuse Fitting- 2 Set.p) Pump Selector Switch- 1 No.q) 100 A, 4-Strip Al. Bus-Bar of minimum 400 mm long and of size 30 mm x 5 mm with sleeve and nut-bolts- 1 Set.r) 200 mm x 150 mm MV Danger Notice Plate of 2 mm thickness- 1 No.s) Earthing Stud- 2 Nos.t) Lifting hook on the top of feeder pillar- 1 Set. u) Lamp Holder inside Feeder Pillar- 1 No.v) 4 Way Neutral Link- 2 Nos.
19Supplying, Fabrication and Installation of 4 mtr. high Pole made out of 65 mm dia. NB, B-class GI Pipe ISI marked duly welded with MS Base Plate of size 300 mm x 300 mm x 12 mm thick with stiffener of size 130 mm x 60 mm x 5 mm thick; top edge to be blunted with a horizontal flat>5 mm (No sharp edge), suitable Earth Stud on Base Plate, making suitable size hole in pole at a height of 2.5 meter from base plate for cable entry/exit, painting & numbering of pole, making suitable size hole in base plate for cable entry/exit into the pole and fixing the pole on the existing foundation with the existing nuts-bolts, washers etc. complete as required.
20Supplying and Fixing of Single Over Hang (SOH) Bracket- for 50-80 dia. MS/GI Pole made of MS Pipe with 300 mm long top galvanized MS Tube of suitable diameter for Light Fitting accommodation, connection etc. complete as required.
21Supplying and Fixing of Double Over Hang (DOH) Bracket- for 50-80 dia. MS/GI Pole made of MS Pipe with 300 mm long top galvanized MS Tube of suitable diameter for Light Fitting accommodation (Angle as per EIC/AE direction).
22Providing and Laying in Position, 1:2:4 (1 Cement : 2 Coarse sand : 4 Graded Stone Aggregate) Reinforced Cement Concrete Foundation of size 450 mm x 450 mm x 1200 mm deep (900 mm below Ground Level and 300 mm above Ground Level) including excavation of earth, refilling, providing, cutting, bending and placing in position, Reinforcement of Cold Twisted Bars of 12 mm dia.- 1200 mm long (approx.)- 8 Nos. and Reinforcement Ring of Cold Twisted Bar of 8 mm dia.- 1400 mm long (approx.)- 6 Nos. (with suitable spacing) including centering & shuttering as required with Providing, Fixing and Positioning of One Set of Foundation Bolts comprising of 4 Nos., 16 mm dia. 750 mm long J-Type MS bolts (Threaded portion shall be galvanized) along with 3 Nos. GI nuts and 2 Nos. GI washers etc. per bolt and 1 No. anchor plate (3 mm thick) of suitable size and providing 63 mm (OD) DWC pipe ISI marked for cable entry & exit etc. complete as required.
23Supplying, Installation, Testing & Commissioning of Street Light LED Fixture Powder Coated Pressure Die Cast Aluminum body with driver as per the requirement with Driver Efficiency>85%, Input voltage: 140-270 Volt AC, Frequency 50/60 Hz, Operating Temp range-5°C to 50°C, Internal Surge Protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency>85%, THD<10% as per IEC 61000-3-2 , PF≥0.95, IP- 66, IK-10, CRI>70, Under Voltage and Over Voltage Protection, EMI-EMC As per CISPR 15, Lenses for Beam Angle as per IESNA type I/II/III as per the width of the road and the project requirement, suitable to fit in up to 65 mm dia. pipe, life time (LED, Driver & Electrical Circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K/4000°K/5700°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching)<5, Maximum Power Consumption should not more than the specified rating and Fixture shall be of relevant BIS Standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC Insulated Copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System Lumen Efficacy≥120<135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED Fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal Management: Heat Sink of Aluminum Housing such that LED Junction Temperature shall not rise above 90°C).45 Watt
24Supply and Installation of Pole Connector Box made out of Glass Reinforced Polyester Sheet Moulding Compound Conforming to IS:13410-1992 Grade-S1 of Outside Dimensions 280 mm (H) x 170 mm (W) x 115 mm (D) (all the corners of the box should be round & not pointed ones) suitable to mount on 40/50/65/80 mm dia. GI Pole with the following Provisions/Accessories Mounting in Box etc. complete as required.a) 2 Nos. Clamps made out of 19 mm x 3 mm MS Strip of suitable Length for Mounting Box on the Pole.b) Water Tight Front Cover with 2 Nos. Stainless Steel Hinges & 1 No. Screw for Tightening.c) 4-Way, 220 V, 30 A, Dough Moulded Connector with SMC with Stainless Steel Inserts- 1 No.d) 16 A, Moulded SMC Rewireable Kit-Kat- 1 No.e) Suitable size Hole at suitable Location on Rear Wall for Cable & Wire Entry in the Connector Box.f) Earthing Bolt M6 x 20 mm.g) Neutral Link- 1 No.
25Supplying of following sizes of XLPE (Cross Linked Poly Ethylene) Insulated PVC Sheathed Alumimium Conductor Armoured Power Cable of 1.1 KV grade including connection, testing etc. as required.2C x 16 sq. mm
264C x 25 sq. mm
27Laying of one number PVC Insulated and PVC Sheathed/XLPE Power Cable of 1.1 KV grade of following size in the Existing RCC/HUME/METAL Pipe as required.Up to 35 sq. mm
28Supplying and Laying of following size DWC HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS: 14930, Part-II complete with fitting and cutting, jointing etc. direct-in-ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia. (OD-63 mm & ID-51 mm nominal)
29Providing and Fixing 6 SWG dia. GI wire on surface or in recess for loop earthing along with existing surface/recessed conduit/sub-main wiring/cable as required.
30Supplying and Drawing of following sizes FRLS PVC Insulated Copper Conductor, Single Core Cable in the Existing Surface/Recess Steel/PVC Conduit as required.3C x 1.5 sq. mm
31Supplying, Installation, Testing and Commissioning of 45-Watt Ruby NXT and GENS LED Post Top with Die Cast Aluminium housing for Gate Light mounted along with CCT-5700 K having Potted Driver, Symmetric Beam, Top Opening (TO) Driver Compartment, Polycarbonate Diffuser, CRI>70, IP-66 complete in all respect including connections with 1.5 sq. mm FRLS, PVC Insulated Copper conductor single core cable and earthing, suitable accessories (like Bracket, nut, bolt) etc. as required.
32Supplying, Installation, Testing and Commissioning of Jeta Quanto Plus Mono Colour Flood Light Luminaire of following Rating and Colour with Pressure Die Cast Aluminium Body and Clear PC Cover, and Standard Beam Angle of 30° with CCT-3000 K having Potted Driver, CRI>70, IP-66 complete in all respect including connections with 1.5 sq. mm FRLS, PVC Insulated Copper conductor single core cable and earthing, suitable accessories (like Bracket, nut, bolt) etc. as required.50 Watt of RED Colour
3350 Watt of GREEN Colour
3450 Watt of BLUE Colour
35Routine Maintenance & Operation of Fountain and other Electrical & Mechanical equipment’s associated with Fountain as per Terms & Condition attached. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56283205
AUTHORITY Local Bodies
TENDER VALUE 28.52 Lakhs
LAST DATE 09-07-2026
Authority
Authority Name Delhi Development Authority
Work Description Tender for maintenance of Completed Scheme Under Nazul Account-Ii, Horticulture Zone.Sh : A) Supplying, Repairing, Installation, Testing & Commissioning And repair maintenance Of Water Fountain With Multicolour Rgb Led Lights, B) Augmentation Of 4 Meter Gi Pole Along With 45-Watt Led Street Light Fittings, Gate Light, Cable Etc. At Hathoda Ram Park Under Hd-2, Horticulture Zone.
Basic Detail
Tender No 26/EE(E)/ELD-12/DDA/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 03 Jul 2026
Submission Date 09 Jul 2026
Open Date 10 Jul 2026
Finance
Tender Value 28.52 Lakhs
Tender Fee Ref. Documents
EMD 57051
Exemption Available
Document List
5e813d90-5071-4f82-b4eb-a08bc6c2e031.html
BOQ_962343.xls
NIT26.pdf
PWD7.pdf
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Jul 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
html

5e813d90-5071-4f82-b4eb-a08bc6c2e031.html

xls

BOQ_962343.xls

pdf

NIT26.pdf

pdf

PWD7.pdf

pdf

Tendernotice_1 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders