Public Administrative Department Local Bodies Closing in 10 days TDR #56282986

Tender For % Construction Of Library Along With Flats (Basement +12) Floors At Nazul Land Located In Birbalsahani Marg, Hasanganj

Issued by Local Bodies · Lucknow, Uttar Pradesh
Tender Value
49.46 Crore
Estimated cost
Bid Submission
17 Jul 2026
10 days left
EMD
98.92 Lakhs
Bank guarantee accepted
Document Fee
4366
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Lucknow → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for % Construction Of Library Along With Flats (Basement +12) Floors At Nazul Land Located In Birbalsahani Marg, Hasanganj

BOQ

Name of Work:- % Construction of Library along with Flats (Basement +12) floors at Nazul Land Located in BirbalSahani Marg, Hasanganj
Sl. No. Item Description
1Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
2All kinds of soil.
3Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
4By Mechanical Transport including loading ,unloading and stacking, Earth ,Earth Lead - 02 km
5Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
6Surface dressing of the ground including removing vegetation and in- equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil
7Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
8Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti- termite treatment (excluding the cost of chemical emulsion) :Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration.
9All kinds of soil
10All kinds of soil.
11With Chlorpyriphos/Lindane E.C. 20% with 1% concentration.
12Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia
13Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. 300 mm dia
141:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
15Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: With 20x20 mm square bar
161:2:4 (1 Cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources).
171:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
18Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads& lifts, all complete as per direction of Engineer -in-charge.
19Man hole cover 455*610mm with frame light duty
201:4 (1 cement: 4 fine sand)
21Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. Circular shape 500 mm internal diameter
2212 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
23Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
24Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
251:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
26Cement mortar 1:4 (1 cement : 4 coarse sand)
27Providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete :( c.o.p.) Sand cast iron S&S as per IS - 3989
28Providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete :( c.o.p.) Sand cast iron S&S as per IS - 3989
29Providing and fixing cast iron terminal guard. Sand cast iron S&S as per IS - 3989
30Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design. 150 mm diameter S.W. pipe
31Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design. 250 mm diameter S.W. pipe
32Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
33Providing and fixing 100 mm/110 mm diameter and 60 cm long rain water spout in cement mortar 1:4 (1 cement : 4 sand). Stone ware spout
34Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade
35Providing and fixing unplasticised PVC connection pipe with brass unions 45 cm length. 15 mm nominal bore
36Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 40 mm nominal outer dia. Pipes.
37Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work-Exposed on wall 32 mm nominal outer dia. Pipes.
38Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work-Exposed on wall 40 mm nominal outer dia. Pipes.
39Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design. 100 mm diameter S.W. pipe
40Providing and fixing M.S. clamp of required dia made of 100 x10 mm flat to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts and nuts of required size complete. 150 mm clamp
41Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar
42Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. : 100 mm diameter
43Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work-Exposed on wall 50 mm nominal outer dia. Pipes.
44Provding and fixing C.I. Double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc. if required will be paid separately. 80 mm dia
45Providing and fixing gun metal gate valve with wheel of approved quality. 25 mm nominal bore
46Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
47Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay F.P.S. (non modular) bricks.
48Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
49Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 . 15 mm nominal bore.
50Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. 250 mm dia. R.C.C. pipe
51Extra for depth for manholes: With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
52Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm nominal outer dia. Pipes.
53Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/ plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia having minimum wall thickness 5.40 mm
54Providing & fixing soil, waste and vent pipes. Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
55Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe. SS 304 grade coupling with EPDM rubber gasket
56Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. : 150 mm diameter
57Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
58Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
59Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
60Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. Sand cast iron S&S as per IS - 3989
61Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. Sand cast iron S&S as per IS - 3989
62Providing and fixing centrifugaly cast iron single equal plain junction of required degree. Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
63Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. 110 mm bend
64Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore
65Providing and fixing C.P. brass shower rose with 15 or 20mm inlet. 150 mm diameter
66Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe. SS 304 grade coupling with EPDM rubber gasket
67Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size) around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground). 150 mm diameter S.W. pipe
68Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work-Exposed on wall 75 mm nominal inner dia. Pipes.
69Providing and fixing gun metal gate valve with wheel of approved quality. 40 mm nominal bore
70Providing and fixing 80 dia G.I. column pipes complete with G.I. fittings including trenching and refilling etc. 80 mm dia. nominal bore
71Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) 80 mm dia nominal bore
72Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work-Exposed on wall 25 mm nominal outer dia .Pipes.
73Providing and fixing gun metal gate valve with wheel of approved quality. 20 mm nominal bore
74Providing and fixing gun metal gate valve with wheel of approved quality. 80 mm nominal bore
75Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m. All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
76Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. 100 mm dia. R.C.C. pipe
77Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
78Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm nominal outer dia. Pipes.
79Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement :2 sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement :5 sand:10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement :3 sand) 12mm thick finished with a floating coat of neat cement complete asper standard design :- With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
80Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. All types of soil 400 mm dia
81Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. All types of soil 400 mm dia
82Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed / plain bevel ended pipe (type A) of required dia, conforming to IS:8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia
83Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
84Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer- in-charge.
85Development of tube well in accordance with IS : 2800 (part I) and IS:11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
86Providing and fixing gun metal non- return valve of approved quality (screwed end) : Vertical
87Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931 15mm nominal bore
88Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.
89Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
90Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe . 40 mm dia
91Providing and fixing Stainless Steel AISI 304(18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40mm including painting of fittings and brackets, cutting and making good the walls wherrerever required. Kitchen sink with drain board Size 510x1040 mm bowl depth 250mm
92Providing and fixing toilet paper holder : C.P. brass
93Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms.
94Providing & fixing soil, waste and vent pipes. Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
95Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
96Providing and fixing plain bend of required degree. Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside as per IS:15905
97Providing and fixing single unequal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete : Sand cast iron S&S as per IS - 3989
98Providing and fixing cast iron terminal guard. Sand cast iron S&S as per IS - 3989
99Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110 mm diameter
100Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. 110mm
101Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. 110x110x110 mm
102Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. 110 mm Shoe
103Providing and fixing centrifugaly cast iron single equal plain junction of required degree. Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
104Providing and fixing plain bend of required degree. Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside as per IS:15905
105Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 20 mm nominal outer dia .Pipes.
106Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 25 mm nominal outer dia .Pipes.
107Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 32 mm nominal outer dia .Pipes.
108Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.. Internal work-Exposed on wall 20 mm nominal outer dia. Pipes.
109Providing and fixing Bail plug / Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 150 mm dia
110Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work-Exposed on wall 62.50 mm nominal inner dia. Pipes.
111Providing and fixing gun metal gate valve with wheel of approved quality. 32 mm nominal bore.
112Providing and fixing gun metal gate valve with wheel of approved quality. 50 mm nominal bore
113Providing and fixing gun metal gate valve with wheel of approved quality. 65 mm nominal bore
114Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. 150 mm dia. R.C.C. pipe
115Providing and fixing single unequal plain invert branch of required degree : Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
116Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 1 12 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
117Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm nominal outer dia. Pipes.
118Making khurras 45x45 cm with average minimum thickness of5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
119Providing and fixing M.S. clamp of required dia made of 100 x10 mm flat to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts and nuts of required size complete. 200 mm clamp
120Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.
121Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931. 15 mm nominal bore.
122Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
123Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 150 x 100 mm size P type With sewer bricks conforming to IS : 4885
124Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
125Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
126Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
127Sewage Treatment Plant 40 KLD based on MBBR Technology \\"Design, Construction, Supplying, Installing, Testing & Commissioning of Compact Sewage Treatment Plant of 40 KLD based on MBBR + UF technology including excavation, back filling & disposal of surplus earth, MS fabrication, Civil construction work for the following duty: \\" The STP shall be designed based on the following inlet parameters: Daily average flow 40 KLD PH 6.5 - 8.3 BOD5 250 - 350 mg/l S. Solids 300 Mg/l COD 400 - 500 mg/L Oil & Grease Approx 20 mg/L Effluent discharge standard after treatment :- ph 6.5 - 8.3 BOD5 < 5 mg/l S. Solids < 1 mg/l COD < 30 mg/l Color Color Less Oil & Grease < 2 mg/l Total Nitrogen < 10 mg/l \\"Design flow (average): 40 KLD = 40 m³/day = 1,666.7 L/hr = 27.78 L/min. Peak hour factor: 1.5 → peak hourly Q = 41.67 L/min.Peak instantaneous (worst short-term): 3.0 → 83.33 L/min (used for selecting common headers/air valves). Influent characteristics (assumed — obtain actual lab values): BOD 300 mg/L, TSS 250 mg/L, pH 6.5–8.5. MBBR aerobic reactor hydraulic retention time (HRT): 4–6 h (I use 5 h for main MBBR sizing below). Equalization tank HRT (recommended): 6 h. Secondary clarifier detention: 2 h. UF recovery: 80% design (adjustable). Design velocities for wastewater piping: 0.8–1.0 m/s (to avoid blocking/sedimentation). Motor & pump efficiencies assumed for power calc: ~60% (use vendor curves for final selection).\\" FLOW CALCULATIONS \\"Average flow = 27.78 L/min Peak hour flow = 41.67 L/min Peak instantaneous = 83.33 L/min\\" PROCESS (typical skid-modular flow) \\"Inlet → Screening → Grit Chamber → Equalization Tank → MBBR Reactor (with aeration) → Secondary Clarifier → UF Feed Tank → UF Skid → Permeate Tank (for reuse) → Disinfection (UV optional) → Reuse / discharge. Sludge handling: sludge withdrawal from clarifier/MLSS → sludge sump → sludge drying/dewatering.\\" TANK SIZING & DIMENSIONS \\"Equalization (EQ) tank HRT: 6 hours → Volume = 40 × 6 / 24 = 10.0 m³. Suggested geometry (rectangular): 3.0 m × 2.0 m × 1.8 m (effective) → ≈10.8 m³ (provide 200–300 mm freeboard). Concrete: RCC tank, inside epoxy coating or PVC lining if required\\" \\"Screen & Grit + Inlet Chamber Small channel with mechanical bar screen or static screen (slot 6–10 mm). Provide grit chamber (detention 1–2 min at peak flow) — volume ~ 0.5–1.0 m³\\" \\"MBBR Aerobic Reactor(s) Design HRT: 5 hours → Volume = 40 × 5 / 24 = 8.33 m³. Provide 30–50% freeboard and compartmentalisation (anoxic/aerobic if required). Typically provide one reactor or two staged reactors (e.g., anoxic + aerobic) depending on BOD/TN requirements. Suggested geometry: 3.0 m × 1.8 m × 1.8 m (effective) → ≈ 9.7 m³ (gives margin). Media fill %: 35–45% of reactor volume (so media volume ≈ 3.4–4.4 m³). Use HDPE media, SSA ≥ 350–500 m²/m³.\\" \\"Secondary Settler / Clarifier Detention 2 hours → Volume = 40 × 2 / 24 = 3.33 m³. For small systems a circular clarifier Ø ~ 1.8–2.2 m, side water depth 1.2–1.5 m is typical. Example: Ø 2.0 m, depth 1.2 m → usable volume ≈ 3.77 m³; choose Ø 2.2 m for margin. Alternative: compact lamella clarifier sized for overflow rate 1.0–2.0 m³/m²·h\\" \\"UF Feed / Clean (Treated Water) Tank UF recovery 80% means permeate taken to tank, concentrate to sludge/return. Provide equalization / buffer for UF permeate: 1–2 m³ (or 2–4 hours of permeate at peak).\\" \\"Sludge Holding / Sludge Sump Sludge storage (thickened) for 7–15 days: for domestic STP of this size you typically provide sludge sump (wet) 1.0–1.5 m³ with sludge transfer pump to periodic dewatering. \\"AERATION & BLOWER SIZING (guideline) Estimated BOD load (assumed): BOD influent 300 mg/L → Load = 0.3 kg/m³ × 40 m³/day = 12.0 kg BOD/day. O₂ required (approx) = 1.2 × BOD removed ≈ ~14–15 kg O₂/day. Aeration blower sizing depends on oxygen transfer efficiency, diffuser type and DO setpoint. For a 40 KLD MBBR typical blower arrangement: Blower capacity: 0.8 – 1.5 m³/min (~50–90 m³/hr) depending on diffuser type and depth (choose based on vendor OTR curves). Blower motor: 1.5–2.2 kW (2–3 HP) duty + 1.5 kW standby (or 1 duty + 1 standby smaller). Provide silencers, anti-vibration mounts and air flow control valve. (Exact blower sizing must be confirmed from manufacturer OTR charts using specific diffuser type, immersion depth and temperature.)\\" PUMP SELECTION — FLOWS & RECOMMENDED SIZES \\"Design approach: Recommended motor: 0.75–1.1 kW (1–1.5 HP) pump, duty + standby (2 nos. on automatic changeover). Material: CI/SS depending on sewage. Provide non-return valve and strainer\\"Duty: 40–80 L/min depending on recirc rate, choose 60 L/min for flexibility. Head: 8–10 m.Motor: 0.75–1.1 kW (1–1.5 HP)\\" \\"UF Feed (high pressure) pump
128Providing and fixing C.P. brass sink mixer of approved quality and make conforming to IS: specification. 15 mm nominal bore
129Providing and fixing END CAP with including fittings complete.
130Providing & fixing soil, waste and vent pipes. 150 mm dia Hubless cast iron pipes including fittings
131Constructing brick masonry INSPECTION chamber 60x60x90 cm with bricks of class designation 50 in cement mortar 1:4 (1 cement : 4 coarse sand) including CI cover with frame LIGHT WEIGHT complete as per design. With FPS bricks
132Submersible Pump include the rate of electrical control panels complete with all accessories &controls, all Electrical/Mechanical items as required to operate the system automatic/manual. c) Level Controller with sufficient nos. of low / high level alarms, contacts with electrodes and control wiring for the automatic operation of water supply pumps, Submersible Sump Pumps, to achieve the functional requirement shall be provided. Control wiring between these pumps and water tanks shall be provided.Domestic water pumps must start at low water level in under ground domestic water tank & stop at high level in that water tank. Dry running protection shall be provided for all the pumps.Sequencing shall be provided for each set of pumps. Supplying & Installation of (350 lpm and 75 mtr head) submersible starter and cable (L&T or BCH make) etc of approved make, and all accessories complete as per requirement of site.
133Providing, installing, testing, and commissioning of a fully automatic Domestic Hydro-Pneumatic Booster Pump System designed to maintain constant pressure for domestic (potable) water supply. The system shall comprise 3 pumps operating in parallel configuration (Duty/Standby arrangement) complete with all required accessories, instrumentation, and intelligent control panel. (Number of Pumps: 3 Nos. (Parallel pumping system – duty/standby operation) (Pump Construction: All wetted parts in Stainless Steel AISI 304 / AISI 316 to ensure hygiene and corrosion resistance) (Seal Material: Carbon / Silicon Carbide / SS316 / EPDM) (Bearing Material: Ceramic / Tungsten Carbide) (Rubber Parts: NBR (Nitrile) – potable water compatible) (Mounting: IEC Standard) (Motor Enclosure: TEFC (Totally Enclosed Fan Cooled) (Power Supply: 3 Phase, 380–415 V, 50 Hz) (Motor Efficiency Class: IE2 or higher) (Header Flange Rating: PN 16) (Pressure Tank: 200 litres, food-grade butyl rubber bladder, epoxy-coated or stainless steel body, rated for system working pressure) (Pump Controller: Intelligent control panel with Single VFD, HMI, and PLC for automatic pressure management, duty cycling, and system protection) (System Components & Accessories: Complete with suction and discharge headers, isolation valves, non-return valves, pressure gauges, pressure transmitter, pressure switch, flexible connectors, base frame, vibration pads, and necessary fittings for complete operation) Flow Rate- 150 lpm 2 Working + 1 Stand By Head 90 m
134Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. . g) Providing & fixing UPVC Coupler i) 160mm dia
135Pump Room for Sump Pump 1 Phase open well submersible pump Supplying &installation of approved make required capacity single phase, 50 Hz, 230V, open well submersible pump, with control panel starter with dry run protection, connections, etc. as required as per specifications but excluding pipe and connection cable. 2.0 HP head metre 14-24, discharge LPM 342-138
136Providing and fixing UPVC pipes complete with fittings and clamps, including cutting and making good walls etc. ( for wash basin & Urinal waste ) 40 mm dia nominal bore
137Providing and fixing in 200X150 ERW Pipe Reducer including fittings complete.
138Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. a) Providing & fixing UPVC 90˚ elbow i) 160mm dia
139Providing and fixing in floor and wall face Ringfit UPVC ASTRAL ULTRADRAIN Conventional system for soil and waste water pipes conforming to (HSN CODE: 3917) Type B including jointing with seal ring. (i) Double socketed pipes. 160 mm
140Providing and fixing plain bend of required degree. a) 150mm
141Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 150x150x150mm
142Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (For bath) . 15 mm nominal bore
143Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe 150 MM SS 304 grade coupling with EPDM rubber gasket
144Providing and fixing 150X150X100 Y Band with including fittings complete.
1451:3:6 (1 Cement : 3 coarse sand(zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources).
146Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation leveling & dressing & finishing the top smooth.
1471:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources).
148Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification.
14980x1.25 mm M.S. laths with 1.25 mm thick top cover.
150Fixing with 15x3 mm lugs 10 cm. long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
151In gratings , frames, guard bar , ladder, railings , brackets , gates and similar works
152Providing and fixing ball bearing for rolling shutters.
153Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
154Providing and fixing bolts including nuts and washers complete.
155Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge
156Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
157Providing & Fixing of Door/ Windows Grill
158Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
15910 x 160 mm
160Using M.S. angels 40x40x6 mm for diagonal braces
161Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
162Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections
163Stairs, (excluding landings) except spiral-staircases
164Concrete of M30 grade with minimum cement content of 350 kg /cum
165Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
166Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick
167Concrete of M30 grade with minimum cement content of 350 kg /cum
168Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
169Concrete of M25 grade with minimum cement content of 330 kg /cum
170Weather shade, Chajjas, corbels etc., including edges
171150 mm wide
172Centering and shuttering including strutting and propping and removal of items for: Foundations, footings, base of columns, etc DSR 2023/5.9.1
173Under 20 cm wide
174Concrete of M25 grade with minimum cement content of 330 kg /cum
175Suspended floors, roofs, landings, balconies and access platform
176Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
177Add for using extra cement in the items of design mix over and above the specified cement content therein.
178Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for each four floors or part thereof. 9 th Floor To Terrace Floor
179Steel Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
180Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for each four floors or part thereof. 5 th Floor To 8th Floor
181Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
182Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.ird course of half brick masonry.
183Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
184Cement mortar 1 : 4 (1 cement : 4 coarse sand)
185Extra for half brick masonry in superstructure, above floor V level for every four floors or part thereof by mechanical means. 9 th Floor To Terrace Floor
186Cement mortar 1:4 (1 cement : 4 coarse sand)
187Extra for brick work / AAC block masonry / Tile brick masonry in superstructure above floor V level, for each four floors or part thereof by mechanical means.5 th Floor To 8th Floor
188Extra for brick work / AAC block masonry / Tile brick masonry in superstructure above floor V level, for each four floors or part thereof by mechanical means. 9 th Floor To Terrace Floor
189Cement mortar 1:6 (1 cement : 6 coarse sand)
190Extra for half brick masonry in superstructure, above floor V level for every four floors or part thereof by mechanical means. 5 th Floor To 8th Floor
191Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474, including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.
192Providing and fixing Glass Reinforced Concrete (G.R.C) Screens casted with 'Spray Mix' concrete design in approved size, pattern, thickness of 50mm on the outer Border & 25-30mm for Internal Member or overall thickness of 40mm and shade. The Screens should be made from ‘43 grade’ Portland Cement manufactured by ‘JK Cement’ or 'Nuvoco' or 'JK Lakshmi' or Ultratech'. White Quartz fine graded seive Silica Sand, Alkali Resistant Glass Fiber manufactured by 'NEG Japan, Owen Corning ‘Saint Gobain’ or equivalent, Super Plasticizers manufactured by ‘Karochem’ or equivalent, Polymers manufactured by ‘Nova Polychem’ or equivalent and U.V resistant Synthetic inorganic pigments should be used for pigmentation manufactured by ‘Phenochem industries or equivalent. The Screens casting shall take place with layering methodology using- Direct Power Spray machines.The GRC Screens flexural strength average L.O.P should be above or equivalent to 6 N/mm2 & M.O.R should be above or equivalent to 12 N/mm2 for tests done on 28 days cured samples. The fixing of Screens should be done using ‘Dry fixing’ method onto structural support members i.e. R.C.C, Brick work MS Framework. MS Galvanized CLAMPS & PINS also if required fasteners to be used of Wurth, Hilti & Fischer or equivalent. All cast in Socket to be epoxy primer coated, electrodes to be used of advani, mangalam, esab or victor brand or equivalent,. Vendor shall submit shop drawings of same, the drawings to be dully approved from Engineer in charge at site.
193Water Swellable Bar:-All Starter & Construction Joints of raft slab, retaining walls : Providing and applying water swellable bar at starter & all construction joints, of c/s size of minimum 20mm X 10mm, volumetric expansion of 300%, Shore A Hardness of 40± 5, hydrostatic head resistance of 60 m. It shall be fixed to the concrete using a hybrid adhesive or corrsion free nailing as recommended by manufacturer.
194Providing and fixing SS Bottom patch Lock with cylinder of approved make including necessary screws etc.
195Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.25M TO 28 M
196Using R2 series with frame (39mm & above ) x (39mm & above) & mullion (39mm & above) x (60mm & above). (Height upto 1.2 meter)
197Using R4 series with frame (64mm & above) x (45mm & above) & sash (44mm & above) x (85mm & above). (Height above 2.5 meter).
198Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. 40M TO 43M
199Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. 34M TO 37M
200Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. 10 M TO 13 M.
201Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. 28M TO 31 M
202Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. 13M TO 16 M
203Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. 19M TO 22 M
204Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. 37M TO 40M
205Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. 16M TO 19 M
206Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. 22M TO 25 M
207Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.l. beading made out of 1.6 mm thick G.l. sheet (zinc coating not less than 120 gm/sqm) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.l. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-Charge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & El. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredited labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 11 00x2200 mm (w x h) or 2.42 sqm.
208Using R3 series with frame (98mm & above) x (40mm & above) & both glazed and fly screen sash (30mm & above) x (55mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi-point locking system, (Height upto 1.8m).
209Using R3 series with frame (55 mm & above) x (50mm & above) & sash (55 mm & above) x (85mm & above) & French (False) mullion (55 mm & above) x (60mm & above). (Height upto 2.5 meter).
210Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet (Zinc coating not less than 120 gm/sqm) suitable for mounting 120 minutes Fire Rated Glazed Door Shutters. The frame shall be filled with mineral wood Insulation having density minimum 96Kg/sqm. The frame will have a provision of G.I. anchor fastners 14 nos (5 each on vertical style & 4 on horizontal style of size M10 x 80) suitable for fixing in the opening along with factory made template for SS ball bearing hinges of size 100x89x3 mm for fixing of fire rated glazed shutter. The fram shall be finished with an approved fire resistant primer or powder coating of not less than 30 micron in desired shade as per the directions of Engineer -in- Charge. (Cost of SS ball bearing hinges is excluded).
211Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/sqm) duly filled mineral wool insulation having density min 96 kg/ cum and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately).
21235 mm thick
213125 mm
2141.0 mm thick.
215Sal wood
216Fixed to steel windows by welding
217250x16 mm
218Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately).
219Providing and fixing bright finished SS 100 mm mortice latch and lock with handle, ISI marked, with six levers and a pair of SS lever handles of approved quality with necessary screws etc. complete.
220Providing and fixing 6mm thick High Performance Toughened Glass having properties of visible Light transmittance (VLT) 28%, ER 27%, IR 10 %, Solar Heat Gain Coefficient (SHGC) 0.30 and U-value 3.7 W/m2 degree-K etc in Doors, Windows & Ventilor. The performance values declared should be tested by third party as well. The thickness/ combination of the glass can vary as per the architects/consultants’ suggestions after checking structural stability of the finalized glass panel.with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge .
221Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimensional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon separator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places. Note:- 2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL (National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL accredited lab or any other accredition body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 (1) Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr (2) Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. (3) Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml (4) Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm (5) Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test. Tests to be conducted on site. (6) Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
222Providing and fixing , lSI Pull Handle H type 32 mm Dia 600 mm marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
223Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
224Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4 mm wide aperture with matching wood beading
225250x10 mm
226Area of slab upto 0.50 sqm
227Area of slab over 0.50 sqm
228Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete
229Supply & fixing of flush doors commercial quality conforming to IS 2202 Part I (1983) including fixing of wooden cleats and stoppers and including fixing and adjustment of hinges bolts locks handles springs fitting with necessary screws to be supplied departmentally (a) 30mm thick
230Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
231With 12 mm mild steel U beading.
232Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm
233With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
234For horizontal surface one coat @1.10 kg per sqm.
235Frame size 65 x 125 mm
236Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of WC. kitchen and the like consisting of 1) Ist course of applying cement slurry 4, 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface) IInd course of 20mm cement plaster 13 (1 cement 3 coarse sand) maxed with water proofing compound in recommended proportion mcluding rounding off junction of vertical and horizontal surface IIIrd course of applying blown or residual bitumen applied hot at 17 Kg per sqm of area iv) IVth course of 400 micron thick PVC sheet (Overlaps at jomts of PVC sheet should be 100 mm wide and pasted to cach other with bitumen 17 Kg/sqm)
237Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthened clear float glass 6mm thick, spacer tube 12mm wide, desiccants, including primary seal and secondary seal (structural silicone sealant) etc., all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Air gap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20%, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by the technical sanctioning authority as per the site requirement.
238Using R3 series with frame (55mm & above ) x (45mm & above) & sash (55mm & above) x (65mm & above) & mullion (55mm & above) x (65mm & above). (Height upto 1.8 meter; each openable shutter upto 0.8m width)
239Providing and fixing frame work for partitions/ wall lining etc. made of 50x50x1.6 mm hollow MS tube, placed along the walls, ceiling and floor in a grid pattern with spacing @ 60 cm centre to centre both ways (vertically & horizontally) or at required spacing near opening, with necessary welding at junctions and fixing the frame to wall/ ceiling/ floors with steel dash fasteners of 8 mm dia, 75 mm long bolt, including making provision for opening for doors, windows, electrical conduits, switch boards etc., including providing with two coats of approved steel primer etc. complete, all as per direction of Engineer-in-charge.
240Providing and fixing non load bearing fixed frame for fire resistant glazed Partition for 120 minutes Fire Rating, made out to a profile of dimension 60mm x 70 mm of 1.6 mm thick galvanised steel sheet as per test evidence suitable for fixing fire rated glass for 120 minutes of both integrity & radiation control (EW120) & minimum 20 minutes of insulation (EI20).The profile has to be fixed to the supporting construction by means of anchor fasteners of size M10 x 80, every 150 mm from the edges and every 500 mm (approx) c/c. Linear measurement of frame shall be measured for payment. The frame shall be filled with mineral wool insulation of density min 96kg/ cum and finished with a approved fire resistant primer or powder coating of not less than 30 micron in desired shade as per NBC 2016, IS 16231 (Part 3):2016 and directions of Engineer - in- charge.
241Upto 20 mm depth and 20 mm width
242For vertical surface two coats @ 0.70 kg per sqm
243Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
24425 mm dia (heavy type)
245Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessaryaccessories and screws etc. complete.
246Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete.
247Powder coated aluminium (minimum thickness of powder coating 50 micron)
248Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc., all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in- Charge.
24930 mm thick
250Supply and fixing of Customized Perforated Screen Panel Cladding fixed system . The Screen panels of various sizes maxing to 900mm x 4200mm as per design requirement shall be manufactured from high corrosion resistant aluminium alloy of 2.00mm thickness which shall be fixed to a suitable and rigid sub structure which will be paid separately. Screen panels will have customized perforation as per architect’s design shall be done on CAD/CAM 5 station auto indexing PIVATIC perforation line with integrated leveler. The leveler shall be of 6 High configuration ARKU technology to achieve super flatness of the panels to avoid waviness/bulging. Panels shall be coated on visible side with Exterior Grade Architectural Bronze Finish of approved color minimum 10 years warranty through in-house high precision powder coating unit. The Powder Coating line shall be with Nano technology & catalytic converter for superior powder coating finishes, automatic electrostatic robotic coating technology for uniform coating and Five (5) tank cleaning process for better adhesion and corrosion protection.The panels of required length and height shall be fixed to sub structure (which will be paid separately) by means of special components as per Worldwide standards. Panels shall be bending from all four sides and shall have extended flanges to accommodate clamps. . Client shall provide sub frame made from Al./Steel/GI.The Panels shall be fixed to a suitable structure (which will be paid separately) by means of fixing side extrusion fixed to the panel at appropriate centers to proprietary metal clamp as per the proprietary HDI design to a support system taking into account the relevant live loads and a dead load. The Panels shall be bend on all four sides and shall have extended flanges with Kidney slots to accommodate the clamps. Installation shall be carried out as per manufacturer recommendation.Green-pro certification: For LEED certification by Indian Green Building Council (IGBC) and ISO 9001: 2008 Quality Management System Certification.Seismic Zone V compliance - Metal facade should be Tested for Seismic Zone V compliance as per IS 1893 part 1-2016”Coating - In-house Powder Coating line with Nano technology & catalytic converter in India: For superior powder coating finishes with automatic electrostatic robotic coating technology for uniform coating and Five (5) times cleaning process with Nano Technology for better adhesion and corrosion protection.
251Providing and fixing factory made ISI marked partially insulated metal fire rated doorset assembly, for staircase / exit pathway and refuge areas applications, consisting of galvanized iron steel frame and double leaf shutter including necessary hardware accessories, conforming to FD 120 PI classification of IS 3614:2021 with fire rating of 120 minutes integrity and 30 minutes insulation. The door frame and shutter shall be made out of minimum 1.20 mm thick GI Sheet with minimum 120 GSM Zinc coating as per IS: 277. The entire fire rated doorset assembly shall be tested as per IS 17518 (Part -1): 2022 Frame: The frame shall be of minimum size 90 x 60 mm with grooved profile to take appropriate fire rated smoke seal, having mitred cut joint (self tab/screwed assembled at site) and provided with appropriate reinforcement suitable for taking hardware and flush fixing as per IS 4351. The smoke seal material shall be of EPDM or any other material tested in accordane with BS 476 (Part-22) ASTM E-84 of minimum size 10 x 4mm, fixed within the inbuilt groove or stuck with adhesive on the entire perimeter of the frame. The door frame shall be fixed to the three sides to masonary wall opening with CSK headed fastner of minimum 8 mm dia size and minimum 80mm long hot dip galvanized with 8mm dia Polyamide sleeves 5 number at each on vertical sides and 3 number on top side. Door shutter: The double skinned double leaf partially insulated door shutters shall be consisting of minimum 50 mm thickness and having box like structure, slots cut and holes punched, for fixing of hardwares with stiffners as per IS: 16074 including resin bonded mineral wool/ceremic wool infill material of minimum density 96 kg/cum. Each door leaf shall be provided with vision panel, having maximum area of 0.06 sqm, of 120 minute fire rated minimum 6 mm thick clear borosilicate glass pane fixed with clip-on arrangement and fire rated ceramic tape having minimum size 13x2 mm to be fixed all around the glass on both the sides. The intumescent seal of minimum size 15x1.5 mm or of size as per test evidence shall be fixed on all the three edges of the door leaves. Integral astragals to be provided for double leaf door on the meeting style each on active and inactive leaf. The door shutters shall be mounted on the frame with SS 304 grade ball bearing hinges as per EN 1935: 2002 or butt hinges as per IS 12817, of minimum size 100x75x3 mm 5 numbers hinges upto 2400mm height or as per test evidence, whichever is more. fixed with M6 25 screws. All doors shall be factory prepared for receiving appropriate hardware and provided with necessary reinforcement for hardware accessories.Accessories Hardware: Fire doorset assembly shall be provided with one number of single point panic push bar (cross bar) for active leaf and one number double point panic push bar (cross bar) of desired finish with verticle shoot bolts on top and bottom for inacitvie leaf of double leaf door as per EN 1125, one number external trim with half cylinder 42 mm long with one side key as per EN 1125, two number heavy duty door closers of size 3-5 with standard arm with of desired finish (suitable for 1250 mm wide door leaf) conforming to IS 3564/EN 1154, and one number surface mounted door coordinator with integral shock absorber.Finishing: Both frame and door shutters shall be factory finished with polyester powder coating of minimum 50 microns thick and shall have passed salt spray test as per IS: 13871 of approved colour and shade all complete as per manufacturer's specifications and as per direction of the Engineer-in-charge. Installation: The hollow space in the door frame shall be filled with fire rated self extinguishing type polyurethane foam (PUF) after installation at site of work. The rate shall be inclusive of complete door assembly, supply and installation by the approved manufacturer.Double leaf partially Insulated metal fire rated doorset of FD 120 PI classification with 120 minutes integrity and 30 minutes insulation as per IS 3614:2021 for Staircase/ Exit pathway / Refuge area etc
252Powder coated aluminium (minimum thickness of powder coating 50 micron)
253Supplying and installing 1.5 mm composite thick fully bonded weldable HDPE membrane conforming to IS 16471:2017 requirements of UG waterproofing structures, requirements to provide Type A fully bonded protection of UG waterproofing structures. The membrane shall exhibit 25 years of service life tested and complied in accordance with EN 13251:2016 durability certification. The membrane should be minimum 2.4 m wide comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weatherproof protective layer with lap Joint Strength at overlaps >15000 N/m ASTM D 6392:2012. The membrane shall have minimum of 100 mm side and end laps which shall be thermofused with leister machines at all the joints for assuring watertightness and achieving monolithic membrane. End laps and side laps should be a minimum of 100 mm with double weld system, comprising of two parallel welds of 15 mm wide each with a 20 mm air channel gap in between the two weld lines.The size of the membrane should not be less than 2.4 Mtr. x 20 Mtr. to minimize the joints. This membrane shall be continued over the vertical surface but terminated minimum 100mm below the top edge of the raft slab/footings and fixed as per recommendation. The HDPE membrane should have the below mentioned techncial properties- 1) Lap Joint(side and end lap) Strength at overlaps 15000 N/m ASTM D 1876 2) Resist hydrostatic pressure of 70 m head of water as per ASTM D5385 3) Puncture Resistance of 1000 N as per ASTM E154 4) Peel Adhesion to concrete of 1500 N/m as per ASTM D 903 5) Tensile strength (Bare HDPE membrane) of 25 N/mm2 as per ASTM D412 6) Elongation (Bare HDPE Membrane) of 500% as per ASTM D 412 7) Low temperature Flexibility -25deg C - Pass as per ASTM D 1970 8) UV Resistance: 45 days
254Providing & applying 2 components, solvent free, liquid applied elastomeric seamless hybrid Polyurea Polyurethane Membrane, using high pressure plural component spray equipment, to form a minimum system thickness of 1.5 mm in two or more passes with a total consumption of 1.5-1.6 kg / m2. The membrane shall have 100% Solids, VOC Free, Tensile strength > 15 Mpa as per ASTM D 412, Elongation > 450% as per ASTM D 412, Low temperature Crack bridging ability of 3.2mm as per ASTM C 1305, Shore A Hardness > 85 ASTM D 2240, Puncture Resistance > 1000 N as per ASTM E 154, Water Head Resistance > 7 Bar as per ASTM D 5385.The coating should pass Dynamic Crack Bridging as per EN 1062-7, Method B for 20,000 cycles at -20 degree temperature. The membrane shall exhibit 25 years of service life tested and complied in accordance with EN 13251:2016 durability certification. Apply primer coat of epoxy primer by roller/ airless spray guideline and coverage @ 5-6 m2/ltr depends on porosity of concrete. Allow to cure for max 5-6 hours. Broadcast anti slip grains of 200-300 micron (dried sand) on wet primer at coverage of 0.8-1 kg/m2 and allow to come to touch dry condition before application of Membrane. Termination of Membrane at 300mm above G.L.-The waterproofing membrane shall be terminated on the vertical surface. The membrane shall be terminated either by creating a \\"U\\" shaped groove of approx. 10 mm x 10 mm size within the RCC retaining wall, tucking the membrane within the groove, followed by sealing the groove with polyurethane sealant/ epoxy mortar . Providing and fixing HDPE protection having dimple height of 6 to 8 mm, as a protection board, over the waterproofing membrane for vertical surface stuck to the membrane by spot bonding method, using synthetic adhesive with butt joints etc. complete. Note-Necessary back filling to be done by the main civil contractor within 2-3 days time progressively after installation of the membrane and protection board , taking care not to cause damage to the waterproofing treatment .
255Providing and fixing factory made ISI marked un-insulated metal fire rated doorset assembly for all egress areas like utility rooms and service areas consisting of galvanized iron steel frame and double leaf shutter including necessary hardware accessories, conforming to FD 120 classification of IS 3614:2021 with fire rating of 120 minutes integrity. The door frame and shutter shall be made out of minimum 1.20 mm thick GI Sheet with minimum 120 GSM Zinc coating as per 15: 277. The entire fire rated doorset assembly shall be tested as per IS 17518 (Part-1): 2022 Frame: The frame shall be of minimum size 90 x 60 mm with grooved profile to take appropriate fire rated smoke seal, having mitred cut joints (self tab/screwed assembled at site) and provided with appropriate reinforcement suitable for taking hardware and flush fixing as per IS: 4351. The smoke seal material shall be of EPDM or any other material tested in accordance with BS 476 (Part-22)/ASTM E-84 of minimum size 10x4 mm, fixed within the inbuilt groove or stuck with adhesive on the entire perimeter of the frame. The door frame shall be fixed in all three sides to masonry wall opening with CSK headed fasteners of minimum 8 mm dia size and minimum 80 mm long hot dip galvanized with 8mm dia polyamide sleeves 5 numbers at each on vertical side and 3 numbers on top side. Door shutter: The double skin double leaf door shutter shall be consisting of minimum 46 mm thick and having box like structure, slots cut and holes punched for fixing of hardware with stiffener as per IS 16074 including Resin bonded honey comb paper core infill material of density 5 kg/cum. Each door leaf shall be provided with vision panel, having maximum area of 0.12 sqm, of 120 minute fire rated minimum 6 mm thick clear borosilicate glass pane fixed with clip-on arrangement and fire rated ceramic tape having minimum size 13x2mm to be fixed all around the glass on both the sides. Integral astragals to be provided for double leaf doors on the meeting style each on active and inactive leaf. The door shutters shall be mounted on the frame with SS 304 grade ball bearing hinges as per EN 1935: 2002 or butt hinges as per IS 12817 both, of minimum size 100x75x3 mm 5 numbers hinges per door leaf upto 2400 mm height or as per test evidence, which ever is more, fixed with M6 25 screws. All doors shall be factory prepared for receiving appropriate hardware and provided with necessary reinforcement for hardware accessories.Hardware Accessories: Fire doorset shall provided with one number fire rated SS 304 grade Mortise dead lock, 50-80 mm Back Set, minimum 20 mm Square forend with allen key Escutcheon of Stainless Steel, and 65/70 mm cylinder with both side key conforming to EN12209/IS: 3614:2021, two pair of D type Pull handle of SS 304 grade of minimum 22 mm dia Centre to centre distance of 300 mm back to back fixing with spindle, one number 300 mm long Concealed lever action flush bolt (Dye-Cast Stainless Steel Finish) at bottom with SS dust proof socket and one number 600 mm long Concealed lever action flush bolt (Dye-Cast Stainless Steel Finish) on top of inactive leaf of double door. Two number fire rated surface mounted heavy duty door closer of size 2-4 with standard arm, of desired finish conforming to IS 3564/EN 1154. Finishing: Both frame and door shutters shall be factory finished with polyester powder coating of minimum 50 microns thick and shall have passed salt spray test as per IS:13871 of approved colour and shade all complete as per manufacturer's specifications and as per direction of the Engineer-in-charge Installation: The hollow space in the door frame shall be filled with fire rated self extinguishing type polyurethane foam (PUF) after installation at site of work. The rate shall be inclusive of complete door assembly, supply and installation by the approved manufacturer.Double leaf un-insulated metal fire rated doorset of FD 120 classification with 120 minutes integrity only as per IS 3614:2021-For egress application like utility and service area.
256Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. 31M TO 34M
257Granite work
258Internal side Surface Preparation- Cleaning the internal surface areas thoroughly so that they are free of all contaminants like dirt and laitance & to remove all the loose materials by various mechanical means. Removal of all surface imperfections, protrusions, loose concrete & filling of cracks using SBR latex modified Mortar in the ratio Cement: Sand (1:4) and 5% by weight of cement.Making “V” grooves cut along the wall & slab joints for 10 x 10 mm using a hand cutter. After cleaning the groove thoroughly, apply one coat of water based primer and filling the gap with PU/Hybrid sealant in the groove. After curing of sealant, apply one coat of water based primer in a width of 120mm, let it cure and fix the Corner Joint tape using waterproofing coating. All Tie rods and Honeycombs should be treated as per standard construction practice. During filling of tie rod leave a gap of 10mm from the surface and the same should be filled with PU/ Hybrid sealant.Pipes treatment: Cleaning and preparation of surface with the help of wire brush or grinder. Clean the surface with water to remove the dust. Insert the pipe with tape wrapped over the pipe into the core and support with formwork. Alternatively, the pipe to be inserted, should be appropriately roughened with hacksaw-blade followed by applying a coat of Epoxy Bonding agent and over this, sprinkling sand which will act as a key to receive non-shrink grout. Pack the core cut junction with non-shrink free flow cementitious grout. Mix ready to use grout with water @ ratio of w/p = 0.13 – 0.15 (depending upon the flowability required) with paddle mixer and pour by providing necessary shuttering and support. Allow the grout to set for 24 hrs. And do the moist curing for 5 days. The area around the pipes (10mm) shall be filled with PU/Hybrid Sealant.Treating of construction joints:Grouting the porous slab area with non-shrink by Drilling holes and injecting cement slurry admix with shrink compensating plasticizing compound @ 225 gms/50kg bag of cement through the nozzles under mechanical pressure grouting pump, Fixing nozzles of 12mm dia with @ 500 mm c/c at an inclined angle over the surface of RCC/ beam/ etc. and along the construction joint line or where honeycombing is present in concrete structures or cracks are dormant/ as per the requirement.Priming- Providing and applying water-based primer, which shall be mixed well and applied using roller/brush over the prepared RCC surface in one coat with coverage of 100 gm/sqm. Self-curing time of 3-12 hours depends upon the climatic conditions. (Ensure the primed surface is tacky condition before application of main coat.Waterproofing Coating- On the Primed surface, providing and applying 2 coats of two-component, solvent-free, thixotropic coating, based on high quality elastomeric polyurethane resin waterproofing coating after mixing the two components. It shall be applied in two coats by roller only @ 1.4 kg/sq.m. (0.5 kg/sq.m. in 1st coat and remaining in 2nd coat). Let the coating cure for 3-5 days for full cure before conducting water ponding test for 24 Hrs. Gap between the two coats application shall not exceed 12 hours. The coating shall have Specific Gravity: 1.2 and solids content of 100%, Elongation of 100% & Tensile Strength of 12 Mpa as per ASTM D412, Shore A hardness of 80 as per ASTM D 2240, Hydrostatic Pressure resistance of 5bar as per EN12390, Adhesion to concrete 2 Mpa as per ASTM D7234 and Water Absorption 0.15 % as per ASTM D570, certified by CFTRI as per 21 CFR 175-300 of US- FDA for potable water contact all as per manufacturers’ specifications, etc complete.(No need of plaster and food grade epoxy/tiles over this coating).
259Library Furniture
260The external and internal signage works. It includes item-wise quantities, rates, and specifications such as 3D channel letters made of extruded aluminium alloy (6063), acrylic faces with vinyl graphics, SS 304 sheets, ACP panels, and MS structural frames. The signages are designed with LED illumination (IP 67 rated power supply), photoluminescent materials, and weatherproof coatings, along with provisions for RCC foundations, anodizing (18–20 microns), and CNCfabricated components, ensuring durability, visibility, and compliance with standards.Signages as per tender Specification & Approved By EIC.
261Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 32 mm dia
262Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 80 mm dia
263Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 40 mm dia
264Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mm dia
265Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 200 mm dia (wall thickness 6.3 mm)
266Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal
267Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 150 mm. Dia
268Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia
269Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 250 mm dia (wall thickness 6.3 mm)
270Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 65 mm dia
271Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 150 mm dia
272Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 150 mm dia
27350 mm dia butterfly valve of PN 1.6 rating
274Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal
275Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : 200mm dia
276Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type,multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 2850 lpm at 88 m Head
277Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : 100mm dia
278Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100mm dia
279Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Gun metal
28025mm Sight Glass
281Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 88 m Head
282Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 200mm dia
283Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
284Providing & fixing flow switch in following sizes M.S.pipe including connection etc as required. 100mm dia
285FRP Hose Box single door (750X600X250) Make: Safex
286Providing & fixing flow switch in following sizes M.S.pipe including connection etc as required. 150mm dia
287Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 80 mm dia
288Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m
289Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a)Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b)Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d)Suitable cement concrete foundation duly plastered 2850 lpm at 88 m Head
290Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 150mm dia
291Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : 80mm dia
292Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : Pendent Sprinkler
293Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : 150mm dia
294Air Release Valve, Gunmetal, having rubber ball with 1” (25mm) BSP Male threaded inlet
295Fireman Axe-made of carbon steel with rubber insulated handle tested to 20,000 Volts as per IS:926
296Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 200mm dia
297Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal
298Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 4 way - 150 mm dia M.S. Pipe
299Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 80mm dia
300Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification Incomings 800A, 50kA 4 Pole MCCB, Ics=100% Icu Rating Digital Voltmeter 0-500V with selector switch Ammeter (0-800 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 1000Amps Outgoings ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) Main Fire Pump 250 Amp, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 100 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets Jockey Pump 125 Amp, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets DIESEL ENGINE CONTROL Control for diesel engine comprising - Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller
301Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : Horizontal side wall sprinkler
302Fire shaft door fabricated out of M.S. sheet and frame, door size of 900 (W) x 2100 (h)x600 with 4 mm thick glass, suitable Rubber beading and Locking arrangement and complete door shall be powder coated with red color powder coating
303Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 1200mm
304Providing, storing, handling, shifting, installation, testing and commissioning of halon free portable fire Extinguishers as described below: Providing and fixing of carbon-di- oxide type fire extinguishers consisting of welded M.S. cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge internal discharge tube 30 cm long high pressure discharge hose,discharge nozzle, suspension bracketconforming to IS : 15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. Capacity 4.5KG
305Providing and fixing of ABC Power type fire extinguishers consisting of welded M.S. cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge internal discharge tube 30 cm long high pressure discharge hose, discharge nozzle, suspension bracket. Conforming to IS: 15683 finished externally with red enamel paint fixed to wall with brackets complete with internal charge. Capacity 6KG
306Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 150mm dia
307Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 50 mm dia
308Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
309Up to 35 sq. mm
310Above 185 sq. mm and up to 400 sq. mm
311150 mm dia
312300 mm dia
3134 C - 35 sqmm (COPPER - PVC - ARMOURED)
314450 mm x 62.5 mm x 2.0 mm thick
315Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required.
316Providing and fixing G.l. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
317200 mm dia (CD-200 mm & ID-175 mm nominal)
3181.2 TR / 1.28 TR
31916 sq. mm 4 core
32070 sq. mm 3-1/2 core
321150 sq. mm 3-1/2 core
322Supply & fixing of 12 Watt LED Bulb - B22 / E27 (Colour Temp.- 6500K / Lumens - 900 lm) cool day light, Input Volts (AC 90V-260V), 3-Star rating suitable for Batten/Angle holder including making connection.Complete in all respect.
3234 X 10 sq. mm (25mm)
324Providing and fixing 25 mm X 5 mm G.l. strip on surface or in recess for connections etc. as required.
325Providing and fixing 6 SWG dia G.l. wire on surface or in recess for loop earthing as required.
3265/6 A switch
3274 way (4 + 12), Double door
32812 way (4 + 36), Double door
329Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
330Supply and fixing of shock treatment chart (prescribed under I.E. rules) duly framed with glass and supported from back with hard board or soft board with supply of all material labour T&P for proper completion of work.
331Supplying, installation, testing and commissioning of 9 meter high octagonal hot dip galvanised (bolt fixing type) with bottom diameter of minimum 118mm (approx) & uniformly tapered to 75mm dia at top with GI base plate of 200mm (L) x 200mm (B) x 12mm thickness having suitable holes for bolts, welded at the bottom of the pole complete with 4 Nos 16mm dia 600 mm long foundation bolts conforming to EN 8 grade, inbuilt/vandal resistance, weather-proof electrical junction box having terminal block, MCB etc mounted on Bakelite sheet for looping in /looping out of cables, with flush door having locking arrangement, earthing arrangement (at least .50 m height) and mounted on RCC foundation of size 500 mm x 500mm x 1000 mm in ground and 200 mm above ground level with foundation bolt duly embedded before casting and supply and embedding of suitable size HDPE pipe sleeve for cable entry complete including erection of pole complete in all respect as per specification.
332Supply, Installation, Testing and Commissioning of BEE 5 Star rated-1200 mm sweep ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 °C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
333Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
334Supplying, installation, testing & commissioning of addressable manual call point complete as required.
335speaker cable Four pair, 2-core, 1.5 sqmm Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.
336SITC of 9U Rack with complete accessories.
337SITC of 8 TB Survillance Hard Disk.
338Supply and laying of CAT 6 UTP cable.
339SITC of 55\\" flat screen FHD professional LED suitable for 24x7 operation with remote control and wall mount unit/floor stand complete with making connection etc as per list of approved makes
3401.6 TR / 1.59 TR
34112.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
342Supply and fixing hexagonal/Round G.P.fan box of approved make made up of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lo
343Supply, Installation, Testing and Commissioning of Workstation PC: Intel(R) Core(TM) i3-12th Gen Processor (8M Cache, up to 3.60 GHz); RAM: 8GB; Keyboard & Mouse; LED Monitor (21\\"); Chassis: Tower/Workstation; DVD: 8X Slimline DVD+/-RW; Data Only; Integrated Graphics Card; SSD : 256GB, Operating system: Windows 11 64 Bit or latest.
344150 mm dia
345Supply, Installation, Testing and Commisioning of LED in 15 W Surface / Recess Mounted Downlighter Round Shape with minimum system lumen efficacy of 100 lm/W and system lumen 1200 lm with Pressure Die cast Aluminium Housing and HET diffuser and P.F.>0.95 ,THD, including making suitable arrangement for fixing , connection with 3 x 1.5 sq.mm. PVC insulated FRLS PVC sheathed copper conductor complete as reqd.
346Supplying, Installation, Testing & Commissioning of mirror light integrated IP20 Batten Led fixture 600 mm 10 W +/- 1W with Surface Mounted with aluminium housing and Polycarbonate diffuser, minimum system efficacy of 100lm/W with P.F.>0.95 with THD < 10%, CRI >80.
34735 sq. mm 3-1/2 core
348300 sq. mm 3-1/2 core
3493-1/2 X 300 sq. mm (70mm)
35010 sq. mm 4 core
35150 sq. mm 3-1/2 core
352185 sq. mm 3-1/2 core
353Supply, Installation, Testing and Commissioning of following minimum capacity High wall type Indoor unit equipped with and comfort washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil,electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50Hz, single phase AC supply, complete as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement automatically. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (Make will be same asof Outdoor). 2.0 TR / 2.02 TR
35419 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm
35522.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm
356Supply ,installation , balancing and commissioning of factory fabricated GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets , elbows, splitter dampers , vanes, hangers , supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.63mm sheet
357Thickness 0.80mm sheet
358Supplying, installation, Testing & Commissioning of 40KVA (Each Power module shall be < 10 KVA) capacity at full load (Unity Power Factor) at operating temperature 0 to 40 deg C, Relative humidity 0 to 95%, Online double conversion true sine wave Uninterrupted hot swappable (allow for the replacement or addition of battery modules without shutting down the entire system) modular Power Supply (UPS) system with N+1 modules (N denotes total number of moduels requird for rated capacity). The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch alongwith provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. UPS shall have inbuilt phase sequence correction. The UPS systems offered are to be of the latest technology with Digital Control Microprocessor based for reliable operation using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter (3 Level) with PWM (Pulse Width Modulation). The quality of design, manufacturing and inspection process should confirm to the relevant International standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >96% while operating on battery mode and delivering quality power to the 100% non-linear loads. Current total harmonic effect(ITHD) on the input grid shall be < 5% at 50 %load. (The required LC (inductor (L) and a capacitor (C)) filters shall be included in UPS cost), extreme power factor kit to be included to limit the input power factor (PF) to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ), however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC : 3Phase 400V +/-20%, 50 Hz +/-5 Hz, AC Output voltage: 3Phase 415 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins, Sine wave output. Non condensing, noise level less than 60db at 1 meter distance, protections: Input Under voltage over voltage, abnormal out voltage, battery over charging, output over current, short circuit protection, battery deep discharge protection, 10KV surge. UPS must comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI)-type UPS. Communication RS232/RS485/SNMP port open protocol for BMS integration, all hardware & software for iOT Communication as per approved by Engineering in charge. Required battery racks and interconnecting copper conductor cables of suitable size and connectors and all required accoseries are inclusive of the cost). This system must provide a means for logging and alarming of all monitored points plus email notification. Forced air-cooling with integral inbuilt fans with redundancy (if one fan fail UPS should be able to handle at least 80% of the load, Noise Level 65 DB at 1 meter distance. The system shall be in compliance IEC 62040- 1,2 & 3, IS:16242 and CPWD Specification. Display Panel (minimum) (In-build 5 inch or more LC Display / LED ) to display : a) Input: Voltage, current, Frequency. b) Bypass: Voltage, Frequency. c) Output: Voltage, frequency, Current.d) Battery: Voltage, Capacity. e) Load: KVA, KW, Percentage. f)Temperature: STS, Inverter, PFC. g) Event Logging & Statistical Data (On LCD/LED): UPS should capture and display up to 3000 events like: Over temperature / DC Bus Fail / Fan Fail / Fuse Fail / Overload / Short-circuit / Device Fail / Inverter Fail / Rectifier Fail / Bypass Fail, etc. h) Statistical Data: No. of power failures / Transfers to Bypass / Total Running time, etc. i) Mains Mode of Operation /Battery Mode of Operation / Bypass feeding the load /UPS Fault /Battery charging and discharging, overload, battery voltage and battery capacity. j) Audible Alarms : Mains Failure, Battery Low Alarm, UPS Overload, Fault, Shutdown, Input Over, Under Voltage, Output Over, Under Voltage, Battery Over, Under Voltage, Over Load and short circuit, Over Temperature. The UPS should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location etc.
3593.6 TR / 3.18 TR
3602.6 TR / 2.56 TR
36115.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
362Up to 35 sq. mm
363Ten Loop Panel.
364Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.
365Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required.
366Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complet
367Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required.
368Thickness1.25mm sheet
369Supply & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers as per specifications.
370Supply, Installation, Testing & Commissioning of Distribution Switch with switching capacity of 1.2 Tbps, forwarding performance of 1000 Mpps with 24x10G SFP++ ports with 2x 40G QSFP+ ports, dual hot swappable internal power supply, 12, 288 IPv4 and 4096 IPv6 ROUTES. MAC Address 250K , Jumbo frame: 9000 bytes. should support layer 3 Routing protocols (RIPng, OSPF v3, IS-IS v6, BGP v6), VRRP v3 for IPv4 and IPv6, support protocol independent multicast ( RIPng, BGP V6, VRRP v3) Minimum 8/16 GB RAM and 8/16 GB flash , should support minimum 256 active VLANs with 3 year support. Shall support AAA, RADIUS, TACACS +, IGMP, UDLD, LACP, SSHv2, SNMPv3, NTP, TFTP. Should support IEEE 802.1D, 802.1s, 802.1w, 802.1x, 802.3ad, 802.3x, 802.1p, 802.1Q.
371Supply, Installation, Testing & Commissioning of CAT 6A UTP Universal (both tool & toolless) information outlet (I/O) in accordance with AMR TIA 568 C.2, IEC 60603-7-4 2nd Edition, ISO/IEC TR 11801-9901-2014, ROHS Compliant. The I/O should have minimu 750 mating cycle and 200 insertion cycle and UL approved, for Data, Voice, & Wi-Fi at user end.
372Supply, Installation, Testing & Commissioning of CAT 6A UTP, LSZH Patch Cord as per AMR/TIA/EIA 568C.2 and UL 94-V-0, ROHS Compliant, patch cord 2 Mtr for end user side switch connectivity.
373Supplying and laying of FRLS PVC Insulated annealed copper conductor 20 pair Armoured Telephone cable etc. complete as reqd.
374Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
375Supplying, installation, testing & commissioning of addressable phone control module complete as required.
376Supplying, installation, testing & commissioning of fire fighter phone jack complete as required.
377Supplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms operating at 240 Volt AC Supply complete as required.
378size 6 sq mm x 3 core Cu. Ar. Cable
3792 X 4 sq. mm + 1 X 4 sq. mm earth wire
380300 mm width X 50 mm depth X 1.6 mm thickness
381Supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell Nitrile rubber (Class\\"O\\") insulation on existing duct after applying suitable adhesive for Nitrile rubber.The joints shall be sealed with 50 mm wide and 3mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 19 mm thick
3824 C - 25 sqmm (COPPER - PVC - ARMOURED)
383Providing and fixing 10 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring / cable as required.
3843-1/2 X 185 sq. mm (57mm)
385Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
386Earthing with G.l. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
387Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
388Providing and laying earth connection from earth electrode with 6 SWG dia G.l. Wire in 15 mm dia G.l. pipe from earth electrode including connection with G.l. thimble excavation and re-filling as required.
389Supply, Installation, Testing and Commisioning of LED fixture 20 W with Surface Mounted 4 Feet with Polycarbonate diffuser with aluminium housing having minimum system lumen efficacy of 125 lm/W with minimum system lumen output 5000 lumens with P.F.>0.95 with THD, including making suitable arrangement for fixing , connection with 3 x 1.5 sq.mm. PVC insulated FRLS PVC sheathed copper conductor complete as reqd.
390Supplying, drawing, testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/on surface, U/FTP, LSZH, Non-Plenum, Horizontal (solid) cable suitable for high-speed data networking application supporting up to 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color-coded insulation for easy identification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer cable diameter should be 7.5 ± 2 mm. Cable should have been tested and verified by UL/ETL etc. complete as required.
391Supplying, Installation, Testing and commissioning of CAT6A Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. All copper cables and components should be from the same OEM to maintain compatibility and interoperability.
392Supply, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s), minimum two compressors (with individual seperate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condensor fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 Degree Celcius. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability.The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be asper Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity 40 and 70 ISEER 5.6 for ECSBC Building) For Cooling or Heating or Both 10 HP TO 12 HP
3931.0 TR / 1.03 TR
394Group B
3954 X 6 sq. mm + 2 X 6 sq. mm earth wire
396Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
397Supply, installation, Testing & Commissioning of 'Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo-Tag of manufacturing location, rating plate as per relevant IS Code etc. and consisting of the followings: (A) Diesel Engine: Turbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications. (B) Engine mounted Instrument Panel fitted with and having digital display for following: (i) Start-stop switch with key (ii) Water temperature indication (iii) Lubrication oil pressure indication (iv) Lubrication oil temperature indication (v) Battery charging indication and Voltage indication (vi) RPM indication (vii) Over speed indication (viii) Low lubricantion Oil trip indication (ix) Engine Running Hours indication (x) Fuel Level (C) Alternator: Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation. (D) Base Frame & Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. (E) FUEL TANK: Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C' pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. (F) Exhaust System: Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor. (G) Starting System: 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. (H) Acoustic and weather proof enclosure: with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air into the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications. (I) AMF Panel: Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for 320KVA for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminum) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM make etc. as per approved by Engineering in charge.
398Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
3993-1/2 X 70 sq. mm (38mm)
400Supply, Installation, Testing & commissioning of of LT Panel, suitable for 415 volts 4 pole, 50 Hz, A.C. Supply. LT Panel shall be single font/double font, totally enclosed compartmentalized type with free standing floor mounted dust and vermin proof indoor type fabricated from 2mm thick CRCA sheet steel for load bearing member and 1.6mm for non load bearing members and complete with Aluminum bus bars, multifunction meter, indicating lamps, protection relays, CT's protection mcb, interconnections with suitable size of solid aluminum strips/power cables & control circuit including breaker control switch, etc as required and as per instruction and approval of Engineer In charge. INCOMER - 1 Nos 63A 4P 15kA MCCB WITH WITH TM RELEASE & Protection BUS BAR - 100A TPN 25 kA AL bus bar OUTGOING 40A MCB FEEDER - 3 Nos
401Supply, Installation, Testing & commissioning of of LT Panel, suitable for 415 volts 4 pole, 50 Hz, A.C. Supply. LT Panel shall be single font/double font, totally enclosed compartmentalized type with free standing floor mounted dust and vermin proof indoor type fabricated from 2mm thick CRCA sheet steel for load bearing member and 1.6mm for non load bearing members and complete with Aluminum bus bars, multifunction meter, indicating lamps, protection relays, CT's protection mcb, interconnections with suitable size of solid aluminum strips/power cables & control circuit including breaker control switch, etc as required and as per instruction and approval of Engineer In charge. INCOMER - 125A 4P 25kA MCCB WITH WITH TM RELEASE & Protection BUS BAR - 200A TPN 25kA AL bus bar OUTGOING 40A MCB FEEDER - 10 Nos
402Supply, Installation, Testing & commissioning of of LT Panel, suitable for 415 volts 4 pole, 50 Hz, A.C. Supply. LT Panel shall be single font/double font, totally enclosed compartmentalized type with free standing floor mounted dust and vermin proof indoor type fabricated from 2mm thick CRCA sheet steel for load bearing member and 1.6mm for non load bearing members and complete with Aluminum bus bars, multifunction meter, indicating lamps, protection relays, CT's protection mcb, interconnections with suitable size of solid aluminum strips/power cables & control circuit including breaker control switch, etc as required and as per instruction and approval of Engineer In charge. INCOMER - 200A 4P 25kA MCCB WITH WITH TM RELEASE & Protection BUS BAR - 320A TPN 25kA AL bus bar OUTGOING 63A MCCB FEEDER - 5 Nos OUTGOING 40A MCB FEEDER - 2 Nos
403Supply, Installation, Testing & commissioning of of LT Panel, suitable for 415 volts 4 pole, 50 Hz, A.C. Supply. LT Panel shall be single font/double font, totally enclosed compartmentalized type with free standing floor mounted dust and vermin proof indoor type fabricated from 2mm thick CRCA sheet steel for load bearing member and 1.6mm for non load bearing members and complete with Aluminum bus bars, multifunction meter, indicating lamps, protection relays, CT's protection mcb, interconnections with suitable size of solid aluminum strips/power cables & control circuit including breaker control switch, etc as required and as per instruction and approval of Engineer In charge. INCOMER - 630A 4P 35kA MCCB WITH WITH TM RELEASE & Protection BUS BAR - 800A TPN 35kA AL bus bar OUTGOING 40A MCB FEEDER - 10 Nos OUTGOING 63A MCB FEEDER - 16 Nos OUTGOING 63A MCCB FEEDER - 2 Nos
404Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
4053-1/2 X 240 sq. mm (62mm)
406Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
407Supplying, installation, testing & commissioning of addressable fire control module complete as required.
408Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
409speaker cable Two pair, 2-core, 1.5 sqmm
410Supplying & laying of 2x1.5 Sqmtm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
411Supply, Installation, Testing and Commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted high ductable type Indoor unit equipped with washable synthetic media pre-filter,fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration Isolators, drain pan, drain pump, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Signals. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (Make will be same as of Outdoor) High Static Ductable units (minimum 78 pascal external static pressure) 6.6 TR / 6.36 TR
41225.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm
41328.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm
41431.8 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm
415Supplying & laying of 2x1.5 Sqmtm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
416Supply and fixing of 60 watt IP66 & IK10 high efficancy highbay fitting with arrangement of hanging hook along with fixing and providing of mounting arrangement at slab and hanging rod complete in all respect including connection with 2.5 sqmm FRLS PVC insulated copper conductor.
417Electric Rubber Hand Gloves 11/15 KV
418Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
419Supplying, Installation, Testing & Commissioning of 13 passenger (884kg) lift with regenerative drive as per CPWD General Specification for Electrical Works (Part-III Lift & Escalator) 2003, BIS Codes, NBC 2016 as amended upto date having provision for barrier free access as per Harmonised Guidelines & Standards for Universal Accessibility in India - 2021 of MoHUA, serving different floors in the lift shaft as per detailed specifications enclosed and as under including all other equipment and accessories complete as required:- (i) Speed-1.0 MPS (ii) Floors-3 (G+2) (iii) Travel-10 Meters (approx) (iv) Stops & opening- 3 stops and 3 openings (v) Controller : A.C. variable voltage & variable frequency (vi) Automatic rescue device (ARD) complete with dry maintenance free batteries as required. vii) Operation: Microprocessor based single automatic push button/simplex selective collective/duplex collective selective with/without attendant. (viii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wires system. (ix) Car Enclosure: Stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish) on all sides and stainless steel decorative ceiling with fans (indirect throw) and LED fitting. (x) The car flooring should be smooth and antiskid as approved by engineer-in-charge. (xi) Type of doors. Car: Power operated, centre opening horizontal sliding stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish). Landing doors: stainless steel scratch proof. (xii) A hand rail not less that 600mm long at 900mm above floor level to be fixed adjacent to control panel in the lift car. (xiii)Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at floor served by the elevator. (xiv) Closed loop Control System, protection against power fluctuation, self diagnostic control, Landing doors 2 hours Fire rated, Overload detection and protection, Overspeed Governer, Dot Matrix LED D & P Indicators In Car & Landings, BMS Compatibility, tamper proof infrared curtain covering almost the entire height of the lift car door, Alarm horn, Anti Nuisance Operation, CCTV camera system with 4 MP IP camera, suitable NVR and HDD for 30 days storage backup , Firemen switch, 2/3 way intercom, Emergency Stop Switch with battery backup for fan and light fitting for 1 hour, pit ladder. (xv) The lift doors shall have a vision panel to enable persons with hearing impairment to signal for help or assistance in the event of an emergency. (xvi) An appropriate technological support be provided (Through emergency messaging |services or alarms etc.) to respond to the emergency requirements of person with hearing impairment or deafness. (xvii) In case of failure of ARD or other electronic devices, a provision of manual rescue be provided.
420Supplying and laying 6 SWG G.l. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with Gl thimble etc. as required.
421Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
42225 sq. mm 3-1/2 core
42395 sq. mm 3-1/2 core
424240 sq. mm 3-1/2 core
4253-1/2 X 150 sq. mm (50mm)
426Supplying and fixing PVC batten/ angle holder including connections etc. as required.
427Supply and fixing of LED Street light 90 Watt fixture powder coated pressure die cast aluminum body with driver efficiency >85%, 140-270 Volt AC, 50/60 hz, -15 deg to 50 deg centigrade, surge protection of 5 KV L,N,E as per IEC 61000-4-5, THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80, EMIEMC As per CISPR 15, lenses for beam angle as per IESNA type I/II/III, life time (LED, Driver & Electrical Circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching)
428SITC of 3MP Dome Camera, 1/3\\" Progressive Scan CMOS, Max. Resolution: 1920 × 1080,Min. Illumination: Color: 0.01 Lux @ (F1.6, AGC ON), B/W: 0 Lux with IR, Shutter Speed:1/3 s to 1/100, 000 s Pan: 0° to 355°, tilt: 0° to 75°, rotate: 0° to 355° 2.8 mm, horizontal FOV 111.6°, vertical FOV 59.3°, diagonal FOV 133.9° 4 mm, horizontal FOV 91.5°, vertical FOV 46.1°, diagonal FOV 109.8° 6 mm, horizontal FOV 56°, vertical FOV 29.8°, diagonal FOV 65.3° Supplement Light Range Up to 40 m Simultaneous Live View Up to 6 channels Wide Dynamic Range (WDR) 120 dB Line crossing, intrusion Motion detection, video tampering alarm, exception Anti-flicker, heartbeat, mirror, password protection, privacy mask, watermark, IP address filter FCC, CE, UL, BIS (IS 13252(Part 1):2010/ IEC 60950-1: 2005) IP67
429SITC of 3MP Bullet Camera 1/3\\" Progressive Scan CMOS, Max. Resolution:1920 × 1080 Color: 0.001 Lux @ (F1.6, AGC ON), B/W: 0 Lux with IR Supplement Light Range Up to 40 m Simultaneous Live View Up to 6 channels, Wide Dynamic Range (WDR) 120 Db, Image Enhancement BLC, HLC, 3D DNR, CERT: FCC, CE, UL, BIS. Protection: IP67
430Supply, Installation, Testing & Commissioning of 64 Channel Network Video Recorder with specifications as follow: Supported Image Format H.264+/H.264, H.265+/H.265, MPEG-4, JPEG, M-JPEG; Supported Image Resolution 1920x1080, 1,280 x 960, 960 x 720, 640 x 480, 320 x 240; Maximum Number of Cameras 64; RAID 5, 320-380 MBps incoming bandwidth Camera Control Pan/Tilt, Zoom, Focus, Brightness, Preset position call and program (up to 256), Auto mode GUI REC/Playback Control REC, PLAY, Rev PLAY, Pause; Network Interface Camera port: 10Base-T / 100Base-TX Min 4x 8TB can be installed. Certification: UL, CE, BIS, FCC.
431SITC of 16 Port POE Switch ,managed PoE, 16 × gigabit PoE ports, and 2 × gigabit fiber optical ports. IEEE 802.3at/af standard for PoE ports. Network topology management, alarm push, network health monitor 6 KV surge protection for PoE ports.AF/AT camera can reach up to 300 m in extend mode. layer 2 management protocols such as STP/RSTP, VLAN, link aggregation, SNMP, QoS ,Switching Capacity 36 Gbps PoE Power Budget 225 W
432Supply, Installation, Testing & Commissioning of 24 Port POE+ Access Switches with switching capaticy of 128 Gbps, forwarding performance 92 Mpps, having 24 x 10/100/1000BASE-T PoE-plus(RJ45) with minimum PoE budget of 370W, with 4 x 10G SFP+ uplink ports. Should Non Blocking architecture , 16K MAC address. Should have Static Routing ,RIP,VRRP, OSPF from day 1,Should support ISSU from day 1 ,Should support stacking with min 12 members in a stack, Neighbor discovery, system logging, Telnet, SSH, SNMP, Network Time Protocol (NTP), IPv6 features from day 1 , MTBF Min 198000 Hr complete etc. as required.
433SITC of PVC Box for Camera.
434SITC of RJ45 Connector Box(100PC).
435SITC of 2U Rack with complete accessories.
436Supply and laying of 1 MTR Patch Cord.
437Supply and laying of 3 core 1.5 sqmm copper unarmoured cable.
4381.0 TR / 1.03 TR
43925 mm thick
440Supplying, laying, effecting proper termination, testing & commissioning of the following POWER CABLE sizes of 1.1 KV - PVC inner sheated,extruded PVC type ST2 sheathed & Galvanised steel strips/wire as per IS 7908 (Part-I) armoured aluminium conductor cables conforming to relevant latest amended Indian Standardsas per specification standard. 4 C - 16 sqmm (COPPER - PVC - UNARMOURED)
4413C x 4 Sq. mm
442300 mm x 50 mm x 1.6 mm thick
443Supply, erection, testing and commissioning of ceiling hunged Tube Axial flow fans with adjustable pitch blade , MS casing, cast aluminium alloy impeller complete with TEFC Sq. Cage Induction motor suitable for 415 volts ± 10%, 50Hz ± 3 %, 4 pole, three phase A.C supply of class \\"F\\" insulation with support, mountings with vibration isolator spring and fire rated canvas flexible connection etc. & of following capacity as per approved shop drawings. Lift Well Air Qty. = 15,000 CFM Static Pressure = 30 mm Wg Fan Speed = Not exceed 1450 rpm Motor = Not exceed 5.5 Kw dB level : not exceed 78 @ 3 mtrs open atmosphere condition.
444Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
4453 pin 5/6 A socket outlet
446Telephone socket outlet
4471 or 2 Module (75mmX75mm)
4486 way (4 + 18), Double door
449100 A.30KA.FPMCCB
450Supplying, Installation, Testing & Commissioning of Floor Mounted panel for Pressurisation fabricated out of 14 SWG sheet steel. The panel should be compartmentalized, free standing, floor mounted, dust and vermin proof. The panel shall be treated for anti corrosive processes (7 tank process) before powder coating. Cable gland plates shall be provided in the panel. Panels shall be suitable for 415 V, 3-phase 4 wire, 50 Hz supply. INCOMER : 63 A TPN MCCB with (0 - 63A) ammeter with three CT & selector switch, (0 - 500 V) voltmeter with selector switch, phase indication light with protection fuse. MCCB shall be of 25KA Bus Bar for 63 A capacity, four pole MCCB. OUTGOING : For 4 Nos. 7.5 HP / 5.5 KW Axial Fan Fan Motor 4 NOS 25 A TPN MCB with 25 A DOL starter, overload relay, start / stop push buttons, on / off / trip indication lights with protection MCB fuses, ammeter ( 0- 25 A) with three CT, single phase preventer / auto manual selector switch. MCB shall be of 16KA. Note: The HVAC contractor shall provide fire shunt relay contact in his panel wherever necessary along with auto/manual mode selector switch in the outgoing feeder for Ventilation Fan to take fire input signal (Potential Free Contact).Cost shall be included in the panel price quoted by him.
451Supplying, laying, effecting proper termination, testing & commissioning of the following POWER CABLE sizes of 1.1 KV - PVC inner sheated,extruded PVC type ST2 sheathed & Galvanised steel strips/wire as per IS 7908 (Part-I) armoured aluminium conductor cables conforming to relevant latest amended Indian Standardsas per specification standard. 3C x 4 Sq. mm
452Supply, Installation, Testing & Commissioning of fiber Modules 10G BASE SM
453Supply, Installation, Testing & Commissioning of loaded 24 port CAT 6A UTP, Transparent shutter jack panel, 1U height, UL-94V-0, Black with cable support bar, clear label marks and earthing plug for CAT6A cable termination at rack end.
454Supply, Installation, Testing & Commissioning of 42U (600W/1000D) floor mount rack with caster wheel base, Fan Tray on Top, 2 cable managers, stationary shelf, 2 Nos. of hardware pkts and C13+C19 PDU with minimum 16 Ports, Vertical Cable Manager.
455Supply, Installation, Testing & Commissioning of 9U wall mount rack with fans on top, 2 cable manager , stationary shelf, 2 Nos. of hardware pkts and C13+C19 PDU with minimum 8 Ports, Vertical Cable Manager.
456Providing & fixing weather proof isolator near each outdoor unit.
457Thickness 1.00mm sheet
458Supply,Fixing, testing & commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored.The spring return action shall be in built mechanism and not externally mounted.The damper shall also be closed in the event of fire signal complete as required and as per specifications. Fire Damper
459Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubbergaskets,nuts,bolts,screws linkages,flanges., as per specifications.
460Providing and fixing testing joint, made of 20 mm X 3 mm thick G.l. strip, 125 mm long, with 4 nos. of G.l. bolts, nuts, chuck nuts and spring washers etc. complete as required.
4612 X 6 sq. mm + 1 X 6 sq. mm earth wire
4622 Pair
463Supply & fixing of 230/250mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect.
464Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
465Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in
466Supply and laying of 1800mm x 900mm x 12mm thick chequered rubbbber matting of tested quality.
467Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.l. tube, having single prong at top, with 85 mm dia 6 mm thick G.l. base plate including holes etc. complete as required.
4681.6 TR / 1.59 TR
469150 mm width X 50 mm depth X 1.6 mm thickness
470Jointing copper / G.l. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
471Providing and laying G.l. tape 32 mm X 6 mm from earth electrode directly in ground as required.
472For Cooling or Heating or Both 14 HP TO 22 HP
473Providing and fixing G.l. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
474Supply, Installation, Testing & commissioning of of Main LT Panel, suitable for 415 volts 4 pole, 50 Hz, A.C. Supply. Main LT Panel shall be single font/double font, totally enclosed compartmentalized type with free standing floor mounted dust and vermin proof indoor type fabricated from 2mm thick CRCA sheet steel for load bearing member and 1.6mm for non load bearing members and complete with Aluminum bus bars, multifunction meter, indicating lamps, protection relays, CT's protection mcb, interconnections with suitable size of solid aluminum strips/power cables & control circuit including breaker control switch, etc. as required and as per instruction and approval of Engineer In charge. CSS INCOMER - 3 Nos 1250A 4P 50kA ACB WITH MICROPROCESSOR RELEASE - 3 Nos. DG INCOMER - 2 Nos 630A 4P 50kA MCCB WITH MICROPROCESSOR RELEASE - 2 Nos. BUS BAR - 3 Nos 2000A TPN 50kA AL Bus Bar BUS COUPLER - 2 Nos 1250A 4P 50kA ACB - 1 No OUTGOING 630A MCCB FEEDER - 5 Nos OUTGOING 125A MCCB FEEDER - 3 Nos OUTGOING 200A MCCB FEEDER - 2 Nos OUTGOING 150A MCCB FEEDER - 1 Nos OUTGOING 100A MCCB FEEDER - 2 Nos OUTGOING 63A MCCB FEEDER - 4 Nos
475Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
4764 X 10 sq. mm + 2 X 6 sq. mm earth wire
4772 X 6 sq. mm (19mm)
4783-1/2 X 25 sq. mm (28mm)
479Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
480Supplying and laying 25 mm X 5 mm G.l. strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.l. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.l. nut bolt & spring washer spaced at 50mm)
4813-1/2 X 50 sq. mm (35mm)
4824 X 16 sq. mm (28mm)
483Supply and laying of 185 sq. mm 3 core standered aluminium conductor XLPE (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cables confirming to I.S. 7098 (Part-II with latest amendments) 11 KV grade at a depth of 900 mm below ground level over a cushion of 100 mm thick fine river sand all around and protected with well burnt bricks on sides and on top put across. The armouring of cable shall be properly connected with earth conductor by clamps etc.
484Supply and fixing of 40 Amp. TP MCB (10 KA) C Curve.
485Supply and fixing of 63 Amp. TP MCB (10 KA) C Curve.
486Supply and fixing the 40 A TPN automatic street light cubicle control panel with anti-corrosive, alkali and acid-proof paint consisting of time switch TSO 100 series with contactors, HRC fuse, isolating switch, metering instrument and instrument box with CTs, etc., complete in all respects.
487Supply, Installation, Testing and Commissioning of Y/T/Multi Joints. Joints shall be of same Original Equipment Manufacturer (OEM) make as of ODUs and IDUs.
488Supply,installation,testing and commissioning of 2core X 1.5 mm² copper wire in PVC conduit as per specifications (for transmission)
489Supply, installation, testing and commissioning of Round / Cabinet type rectangular Inline fans with motor complete motor complete with TEFC Sq. Cage Induction motor suitable for 220 volts ± 10%, 50Hz ± 3 %, single phase A.C supply of class \\"F\\" insulation with , mountings accessories in all respect with wiring upto power supply point & of following capacities as per specification and tender drawing mentioned. 600 cfm / 25mm St.Pr.
490Supply, installation, testing and commissioning of drain piping of hard UPVC pipe and fittings, insulated with 12 mm thick nitrile rubber. 25mm
491Supply & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
492Supply, fixing testing commisioning of Supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.
493Supplying & fixing of 18 G thick Aluminium extruded powder coated Fresh / Exhaust air weather protected louvers with bird screen type (with Aluminium frames if required) for ventilation with 12G GI wire mesh as per specification and sizes will be as per tender drawing mentioned.
494240 sq.mm
495Supply of Outdoor type 11 KV Compact Sub-station (CSS) suitable for 11 kV, 50Hz, with Transformer and with HT Switchgear, LT Switchgear, Cable termination facility for HT & LT side, internal illumination, Earthing, interconnection of Transformer with HT & LT equipment, suitable for ready Plinth and comprising of the following - * Outdoor type enclosure having modular construction of 1.6/2.00 mm CRCA sheet steel. * The enclosure shall have IP54 degree of protection for HT & LT compartment & IP23 degree of protection for Transformer compartment. * The enclosure exterior shall be painted with epoxy-based powder coated paint (Colour RAL 7032). The bottom base frame shall be welded and black painted Channel structure with lifting arrangement for the completely assembled CSS. The Įouvers shall be painted with Royal Blue Colour. * Each compartment is provided with door and pad locking arrangement. * The Compartment illumination lamp with door operated switch shall be provided for each compartment. * The Transformer compartment is provided with limit switch to trip the HT Switchgear; in case the Transformer compartment door is inadvertently opened in LIVE condition. The work shall be complete in all respects up to the satisfaction of Engg-in-charge. Outdoor type package type substation with continuous rating 630 KVA, Step Down, 11/0.433 kV ONAN Transformer, Hermatically sealed corrugated Tank (Manufactured as per IS 1180, Level-II (New), Vector Group DYn11, OFF Load Tapping +5% to -10% in steps of 2.5%, Winding-Double Wound Copper, A Class Insulation, 50 Deg C Ambient Temp,% Impedence 5%. HT SECTION HT Switchgear - Three way, 11 KV, 630 Amps, SF6 Insulated Non Extendable Compact Switchgear. TRANSFORMER SECTION 630 KVA 11/0.433 KV Cast Resin Dry Type Transformer With OLTC and standard fittings conforming to IS-11171/2021 Energy Efficiency Level- II. LT SECTION 2 Nos ACB 1250A FP EDO OL,SC,EF with display (minimum 03 line & maximum 04 line) with communication module for real data assessment like events, fault and all current parameters.
496Supply, Installation, Testing & Commissioning of LC-SC singlemode OS2 (9/125) duplex, LSZH armoured fiber patch cord for LIU to switch connectivity. Patch Cord should have aramid yarn as strenght member with 1000 time mating cycle.
497Supply, Installation, Testing & Commissioning of CAT 6A UTP, LSZH Patch Cord as per AMR/TIA/EIA 568C.2 and UL 94-V-0, ROHS Compliant, patch cord 1 Mtr for rack side switch to end user connectivity.
498Supply, Installation, Testing & Commissioning of Hybrid 100% IPPBX System Supporting 400 Analog, 8 Digital Telephone extensions, IP extensions support in built 2 port auto sensing 10/100 MBPS LAN switch Layer 3 and BRI/PRI/T1/E1/E1R2/and GSM/3G/4G/VoLTE. The nextgeneration platform should support up to 64 VoIP (SIP) trunks, 40 GSM ports, 8 T1/E1 ISDN PRI ports, and 32 analog trunks with up to 600 UC users, 64 digital users, and 240 analog usersFully Digital Integrated Services Digital Network (ISDN) auto sensing Compatible Voice Over Internet 23 Telephone(VolP). The IPBX/PABX/Communication System shall employ IP at its core with IP switching technology and 100% non- blocking. System should have Gigabit ports for Web-based Configuration, PMS, SMDR, System Log, VOIP (LAN and WAN) and VMS etc. complete as reqd.
499Supply, Installation, Testing & Commissioning of 100 Pair Krone Box Module.
50034.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm
50138.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm
502Supply and laying of 25mm dia PVC conduit including accessories.
503Supplying, Installation, Testing & Commissioning of 13 passenger (884kg) lift with regenerative drive as per CPWD General Specification for Electrical Works (Part-III Lift & Escalator) 2003, BIS Codes, NBC 2016 as amended upto date having provision for barrier free access as per Harmonised Guidelines & Standards for Universal Accessibility in India - 2021 of MoHUA, serving different floors in the lift shaft as per detailed specifications enclosed and as under including all other equipment and accessories complete as required:- (i) Speed-1.5 MPS (ii) Floors-13 (B+G+11) (iii) Travel-45 Meters (approx) (iv) Stops & opening- 13 stops and 13 openings (v) Controller : A.C. variable voltage & variable frequency (vi) Automatic rescue device (ARD) complete with dry maintenance free batteries as required. vii) Operation: Microprocessor based single automatic push button/simplex selective collective/duplex collective selective with/without attendant. (viii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wires system. (ix) Car Enclosure: Stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish) on all sides and stainless steel decorative ceiling with fans (indirect throw) and LED fitting. (x) The car flooring should be smooth and antiskid as approved by engineer-in-charge. (xi) Type of doors. Car: Power operated, centre opening horizontal sliding stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish). Landing doors: stainless steel scratch proof. (xii) A hand rail not less that 600mm long at 900mm above floor level to be fixed adjacent to control panel in the lift car. (xiii)Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at floor served by the elevator. (xiv) Closed loop Control System, protection against power fluctuation, self diagnostic control, Landing doors 2 hours Fire rated, Overload detection and protection, Overspeed Governer, Dot Matrix LED D & P Indicators In Car & Landings, BMS Compatibility, tamper proof infrared curtain covering almost the entire height of the lift car door, Alarm horn, Anti Nuisance Operation, CCTV camera system with 4 MP IP camera, suitable NVR and HDD for 30 days storage backup , Firemen switch, 2/3 way intercom, Emergency Stop Switch with battery backup for fan and light fitting for 1 hour, pit ladder. (xv) The lift doors shall have a vision panel to enable persons with hearing impairment to signal for help or assistance in the event of an emergency. (xvi) An appropriate technological support be provided (Through emergency messaging |services or alarms etc.) to respond to the emergency requirements of person with hearing impairment or deafness. (xvii) In case of failure of ARD or other electronic devices, a provision of manual rescue be provided.
504Supplying, Installation, Testing & Commissioning of 20 passenger (1360kg) lift with regenerative drive as per CPWD General Specification for Electrical Works (Part-III Lift & Escalator) 2003, BIS Codes, NBC 2016 as amended upto date having provision for barrier free access as per Harmonised Guidelines & Standards for Universal Accessibility in India - 2021 of MoHUA, serving different floors in the lift shaft as per detailed specifications enclosed and as under including all other equipment and accessories complete as required:- (i) Speed-1.5 MPS (ii) Floors-13 (B+G+11) (iii) Travel- 42 Meters (approx) (iv) Stops & opening- 13 stops and 13 openings (v) Controller : A.C. variable voltage & variable frequency (vi) Automatic rescue device (ARD) complete with dry maintenance free batteries as required. vii) Operation: Microprocessor based single automatic push button/simplex selective collective/duplex collective selective with/without attendant. (viii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wires system. (ix) Car Enclosure: Stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish) on all sides and stainless steel decorative ceiling with fans (indirect throw) and LED fitting. (x) The car flooring should be smooth and antiskid as approved by engineer-in-charge. (xi) Type of doors. Car: Power operated, centre opening horizontal sliding stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish). Landing doors: stainless steel scratch proof. (xii) A hand rail not less that 600mm long at 900mm above floor level to be fixed adjacent to control panel in the lift car. (xiii)Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at floor served by the elevator. (xiv) Closed loop Control System, protection against power fluctuation, self diagnostic control, Landing doors 2 hours Fire rated, Overload detection and protection, Overspeed Governer, Dot Matrix LED D & P Indicators In Car & Landings, BMS Compatibility, tamper proof infrared curtain covering almost the entire height of the lift car door, Alarm horn, Anti Nuisance Operation, CCTV camera system with 4 MP IP camera, suitable NVR and HDD for 30 days storage backup , Firemen switch, 2/3 way intercom, Emergency Stop Switch with battery backup for fan and light fitting for 1 hour, pit ladder. (xv) The lift doors shall have a vision panel to enable persons with hearing impairment to signal for help or assistance in the event of an emergency. (xvi) An appropriate technological support be provided (Through emergency messaging |services or alarms etc.) to respond to the emergency requirements of person with hearing impairment or deafness. (xvii) In case of failure of ARD or other electronic devices, a provision of manual rescue be provided.
505Providing and fixing 8 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring / cable as required
506Supply and installing following size of perforated painted with powder coating M.S Cable trays with perforation not more than 17.5% , in convinient sections , joined with connectors, suspended from the ceiling with M.S suspenders including bolts & nuts , painting suspenders etc as required. 150mm x 50mm x 1.6 mm thick
507600 mm x 62.5 mm x 2.0 mm thick
508Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchangerIS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). 1.5 TR with 5 star BEE Rating
509120 mm dia (CD-120 mm & ID-103 mm nominal)
510Supply & fixing of 300mm sweep ventilating (Medium Heavy Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Double ball bearing /Copper motor /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 70/85 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 900 RPM. Complete in all respect.
511Above 95 sq. mm and up to 185 sq. mm
512Above 35 sq. mm and up to 95 sq. mm
513Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
5143-1/2 X 35 sq. mm (32mm)
5152.0 TR / 2.02 TR
516Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories,insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required: 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
5179.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
51841.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm
519Above 35 sq. mm and up to 95 sq. mm
520Group B
521Supply and fixing of recess/surface/pendent mounting round 6 to 8 W LED Down lighiter having powder coated die cast aluminium housing with heat shink, diffuser/reflector and driver set efficiency >85%, System lumen efficacy ≥120 < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating)
522Supply, Installation, Testing and Commisioning of IP65 Bulkhead led fixture 10 W +/- 1 W Wall Mounted with minimum system lumen efficacy of 100 lm/W with Pressure Die Cast Aluminum housing, Polycarbonate Opal Diffuser and P.F.>0.95 with THD, including making suitable arrangement for fixing , connection with 3 x 1.5 sq.mm. PVC insulated FRLS PVC sheathed copper conductor complete as reqd.
52332 mm
524Supply, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan / dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Signals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (Make will be same as of Outdoor) 4.1 TR / 3.98 TR
5252X1.5 sq. mm + 1 X 1.5 sq. mm earth wire
5262 X 2.5 sq. mm + 1X2.5 sq. mm earth wire
52725 mm
528Supply, Installation, Testing & commissioning of of LT Panel, suitable for 415 volts 4 pole, 50 Hz, A.C. Supply. LT Panel shall be single font/double font, totally enclosed compartmentalized type with free standing floor mounted dust and vermin proof indoor type fabricated from 2mm thick CRCA sheet steel for load bearing member and 1.6mm for non load bearing members and complete with Aluminum bus bars, multifunction meter, indicating lamps, protection relays, CT's protection mcb, interconnections with suitable size of solid aluminum strips/power cables & control circuit including breaker control switch, etc as required and as per instruction and approval of Engineer In charge. INCOMER - 630A 4P 35kA MCCB WITH WITH TM RELEASE & Protection BUS BAR - 800A TPN 35kA AL bus bar OUTGOING 125A MCCB FEEDER - 7 Nos OUTGOING 100A MCCB FEEDER - 2 Nos
529Supply, Installation, Testing & commissioning of of LT Panel, suitable for 415 volts 4 pole, 50 Hz, A.C. Supply. LT Panel shall be single font/double font, totally enclosed compartmentalized type with free standing floor mounted dust and vermin proof indoor type fabricated from 2mm thick CRCA sheet steel for load bearing member and 1.6mm for non load bearing members and complete with Aluminum bus bars, multifunction meter, indicating lamps, protection relays, CT's protection mcb, interconnections with suitable size of solid aluminum strips/power cables & control circuit including breaker control switch, etc as required and as per instruction and approval of Engineer In charge. INCOMER - 630A 4P 35kA MCCB WITH WITH TM RELEASE & Protection BUS BAR - 800A TPN 35kA AL bus bar OUTGOING - FOR UNITS : 36 Nos. 63 Amps FP MCB 10kA (C-Curve) in meter box with provision of viewing window and ACCL (Automatic Changeover with Current Limiter) at each meter box as per SLD for ristricting 1A-10Amp (0.5 kW) at Gen Side & 30A-40A (6-7kW) at Mains, CT based real-time oprations, DG Backup supply upto 0.5 KW with providing and fixing of 0A-60A 3-Phase Digital Energy Meter as duly aproved from SEB. 4 Nos. 63 Amps FP MCB 10kA (C-Curve) with space for meter box provision 63 Amp FP MCCB - 1 No. (Spare) 100 Amp FP MCCB - 1 No. (Spare)
530Supply, Installation, Testing & commissioning of of LT Panel, suitable for 415 volts 4 pole, 50 Hz, A.C. Supply. LT Panel shall be single font/double font, totally enclosed compartmentalized type with free standing floor mounted dust and vermin proof indoor type fabricated from 2mm thick CRCA sheet steel for load bearing member and 1.6mm for non load bearing members and complete with Aluminum bus bars, multifunction meter, indicating lamps, protection relays, CT's protection mcb, interconnections with suitable size of solid aluminum strips/power cables & control circuit including breaker control switch, etc as required and as per instruction and approval of Engineer In charge. INCOMER - 125A 4P 25kA MCCB WITH WITH TM RELEASE & Protection BUS BAR - 200A TPN 25kA AL bus bar OUTGOING 32A MCCB FEEDER - 2 Nos OUTGOING 16A MCB FEEDER - 40 Nos
531Supply, Installation, Testing & commissioning of of LT Panel, suitable for 415 volts 4 pole, 50 Hz, A.C. Supply. LT Panel shall be single font/double font, totally enclosed compartmentalized type with free standing floor mounted dust and vermin proof indoor type fabricated from 2mm thick CRCA sheet steel for load bearing member and 1.6mm for non load bearing members and complete with Aluminum bus bars, multifunction meter, indicating lamps, protection relays, CT's protection mcb, interconnections with suitable size of solid aluminum strips/power cables & control circuit including breaker control switch, etc as required and as per instruction and approval of Engineer In charge. INCOMER - INPUT SIDE 100A 4P 25kA MCCB WITH WITH TM RELEASE & Protection INCOMER - OUPUT SIDE 100A 4P 25kA MCCB WITH WITH TM RELEASE & Protection BUS BAR - 250A TPN 25kA AL bus bar OUTGOING 40A MCCB FEEDER - 2 Nos OUTGOING 40A MCB FEEDER - 8 Nos
532Supply, Installation, Testing & commissioning of of LT Panel, suitable for 415 volts 4 pole, 50 Hz, A.C. Supply. LT Panel shall be single font/double font, totally enclosed compartmentalized type with free standing floor mounted dust and vermin proof indoor type fabricated from 2mm thick CRCA sheet steel for load bearing member and 1.6mm for non load bearing members and complete with Aluminum bus bars, multifunction meter, indicating lamps, protection relays, CT's protection mcb, interconnections with suitable size of solid aluminum strips/power cables & control circuit including breaker control switch, etc as required and as per instruction and approval of Engineer In charge. INCOMER - 150A 4P 25kA MCCB WITH WITH TM RELEASE & Protection BUS BAR - 200A TPN 25kA AL bus bar OUTGOING 32A MCCB FEEDER - 4 Nos OUTGOING 40A MCCB FEEDER - 4 Nos OUTGOING 63A MCCB FEEDER - 4 Nos
5333-1/2 X 95 sq. mm (45mm)
534Supply, installation, testing & commissioning of Central Controller capable of controlling of all IDUs, ODUs complete with necessary hardware, accessories etc. to perform the following functions: Control of IDUs, ODUs Units as above with monitoring of vital parameters such as temperature sensing & setting, ON/OFF, status etc. Permit / prohibit function of each remote controlled unit. Operation of units in individually or in group. Fault indication with Alarm. The central controller will be complete including all hardware & software (including wiring) suitable to perform above function.
535Supply, installation, testing and commissioning of 2core X 1.5 mm2 copper wire in PVC conduit as per specifications (for remotes)
536Supply and installing following size of perforated painted with powder coating M.S Cable trays with perforation not more than 17.5% , in convinient sections , joined with connectors, suspended from the ceiling with M.S suspenders including bolts & nuts , painting suspenders etc as required. 150mm x 50mm x 1.6 mm thick
537Actuator
538Supply, fixing testing commisioning of Return air diffusers of powder coated aluminium without aluminium volume control dampers with anti smudge ring & removable core.
539Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.
540Supplying, installation, Testing & Commissioning of 35W Panel light 2x2 ft., of Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm) material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with ,70% of initial Lumen maintained till life ends, CCT 3000°K/4000°K/5700°K/6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching)
541Supply, Installation, Testing & Commissioning of of Access Switch 24 Port POE+Access Switches with switching capacity of 240 Gbps, forwarding performance 190 Mpps, having 24 x 10/100/1000BASE-T PoE-plus(RJ45) with minimum PoE budget of 720-740 W and 4x10G SFP+uplink ports, should support and supply redundant power supply, should have support for 8 switch Stacking with stacking cable with bandwidth of minimum 80 Gbps. Should support min 2GB internal DRAM, 1024 MB internal Flash memory, 16K MAC address, 512 IPv4 and 256 IPv6 multicast route, should support 256 active VLANs Should should support layer 3 routing, static & dynamic routing, RIPv1/v2, OSPF and VRRP v3 for IPv4 and IPv6, support protocol independent multicast, Shall support AAA, RADIUS, TACACS+, IGMP , UDLD , LACP , SSHv2 , SNM Pv3 , NTP , TFTP. Should support IEEE 802.1D, 802.1s, 802.1w, 802.1x, 802.3ad, 802.3x, 802.1p, 802.1Q. 3 years support , must be of same make as that of Distribution switch.
542Supply, Installation, Testing & Commissioning of 24F SM loaded LIU with LC adaptor plates, pigtel cables, Spilce tray, cable holder and 4 nos of cable entry exist point with rubber gurment along with the LIU, Powder Coaded 1.2mm steel sheet metal, 1U etc complete as required. LIU should be in accordance with YD/T 778-2006 Optical Distribution Frame & YD/T 1272.1-2003 Optical Fiber Connector Part 1: Type LC.
543TV antenna socket outlet
544Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
545Up to 450 mm sweep
546Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
547Supplying and fixing call bell/ buzzer suitable for single phase, V, complete as required.
5488 way (4 + 24), Double door
5494 way (4 + 12), Double door
550125 A.36KA.FPMCCB
551Bell push
552Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
553Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
554Supplying & fixing suitable size Gl box with modular plate and cover in fronton surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
555Single pole
556Above 185 sq. mm and up to 400 sq. mm
557Above 95 sq. mm and up to 185 sq. mm
558100 mm dia
559Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.
560Supplying, installation, testing & commissioning of fault isolator complete with base as required.
561Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.
562Supply, Installation, Testing & Commissioning of armoured 12 core Singlemode OS2 (9/125 Micro), Corrugated ECCS Armor, HDPE (UV) Sheathing, Theoxtropic gel filled OFC cable with 2 Nos steel music wire embedded in side sheathing as stregth member for switch connectivity. Cable should be ROHS compliant and as per IEC60749-1.
563Supplying, Installation, Testing & Commissioning of Analog phones having standard features like 16 digit LCD display, 2 way speaker, caller ID and number storage facility etc. complete as required.
564Supplying, Installation, Testing & Commissioning of Type 1 IP Phone having 2 VoIP account, 120 x40 DOT matrix screen with backlight, Full HD duplex speaker phone, IPV6, Gigabit Ethernet, PoE etc. complete as required.
565Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm x 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications.
5663C x 6 Sq. mm
567Providing and fixing 10 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring / cable as required
568240 sq.mm
5691:3 (1 cement: 3 fine sand)
570Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour: New work (two or more coats) over and including Water thinnable priming coat with cement primer having VOC content less than 50 gram/litre.
571New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
572Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
573Neat cement punning
574New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @2.20kg/10 sqm.
575Two or more coats on new works including a coat of wood filler.
5761:6 (1 cement: 6 coarse sand)
577Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
578Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
5791:6 (1 cement: 6 coarse sand)
580New work (three or more coats)
581Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture
582Cement concrete prepared with batch mixing machine.
583Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge.
584With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30
585Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re- olling the sub grade and disposal of surplus earthwith lead upto 50 metres.
586Providing and applying 2.5 mm thick road marking strips (retro-reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications.
587Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).
588Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
589Providing and fixing Glow studs of size 100x20 mm made of heavy duty body shall be moulded ASA (Acrylic styrene Acryloretrite ) or HIP (High impact polystyrene) or ABS having electronically welded micro- prismatic lens with abrasion resistant coating as approved by Engineer in charge. The glow stud shall support a load of 13635 kg tested in accordance with ASTM D4280. The slope of retro- reflective surface shall be 35 (+/-5) degress to base .The reflective panels on both sides with at least 12 cm of reflective area up each side. The luminance intensity should be as per the specification and shall be tested as described in ASTM I: 809 as recommended in BS: 873 part 4 : 1973. The studs shall be fixed to the Road surface using the adhesive conforming to IS, as per procedure recommended by the manufacturer complete and as per direction of Engineer-in-charge.
590Cautionary /warning sign boards of equilateral triangular shape having each side of 900 mm with support length of 3650 mm
591Providing Retro-reflective regulatory sign board of size 900 mm dia meter made out of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated lens type retro-reflective sheeting as approved by Engineer-in-charge . Letter, symbols, borders etc. will be as per IRC - 67 with required colour scheme on the boards and with the high intensity grade A. The aluminium sheet to be riveted to M.S. frame of angle iron of size 40x40x4 mm. The boards will be fixed to 1 No. 50x50 mm square post made of M.S. angle 50x50x4 mm, 4 m long welded to the frame with adequate anti-theft arrangement .Sheet work to be painted with two or more coats of synthetic enamel paint over an under coat (primer) and back side of aluminium sheet to be painted with two or more coats of epoxy paint including appropriate priming coat complete in all respects as per direction of Engineer-in-charge.
592Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
593With material conforming to Grade-III(size range 26.5 mm to 0.075 mm) having CBR Value-20
594Mandatory/ Regulatory sign boards of 900 mm diametre with support length of 3750 mm
59580mm thick Cement concrete paver block of M-30 grade with approved colour, design & pattern.
596Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.)
597Supplying and stacking sludge at site including royalty and carriage upto 5 km lead complete (sludge measured in stacks will be reduced by 8% for payment).
598Screened through sieve of I.S. designation 20 mm
599Grassing with selection No. 1 Doob grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and good earth shall be paid for separately). In rows 5 cm apart in both directions
600Providing and stacking of Nyctanthes arbor-tristis (Hasingar) of ht. 90-105 cm in Earthen pots of size 20 cm as per direction of the officer-in-charge.
601Providing and Displaying Furcaria Variegated hybrid well developed with fresh & healthy foliage 20 and above attractive leaves in 35 cm Cement Pot as per direction of the officer-in-charge.
602Fine dressing of the ground.
603Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).
604Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge
605Providing and displaying of Aglaonema Silver Queen having 30 cm to 45 cm. ht. with 12 to 15 leaves, multi suckers, fresh and healthy leaves, well developed in 25 cm dia Earthen pot/Plastic pot & as per direction of the officer-in-charge.
606Providing of Schefflera Green (three in one), mounted on moss stick 90 cm, well developed with full of fresh & healthy leaves from bottom to top with rich foliage in 25 cm size of Earthen pot/Plastic pot.as per direction of officer-in-charge.
607Providing and stacking of Cassia biflora of height 45-60 cm. in earthen pots of size 20 cm as per direction of the officer-in-charge.
608Providing and stacking of Hamelia patens of height 30-45 cm. with 3-4 branches in poly bags of size 20 cm as per direction of the officer-in-charge.
609Providing and stacking of Plumbego capensis well developed with fresh and healthy 30 to 45 cm ht., with bloom in 20 cm Earthen Pot/Plastic Pot as per direction of the officer-in-charge.
610Providing and Displaying Ficus nuda topiary well developed with fresh & healthy foliage 45 to 60cm spread 75 to 90 cm ht. bushy in 35 cm Cement Pot as per direction of the officer-in-charge.
611Providing and Displaying Cyprus Golden 30 to 45 cm ht. well developed good Golden colour foliage, Conial Shape in 25 cm Earthen Pots as per direction of the officer-in-charge.
612Providing and stacking of Euphorbia milli hybrid variety, having ht. 30 cm to 45 cm with multi branch, full bloom, fresh and healthy leaves in 30 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge..
613Providing and displaying of Money Broad Leaves mounted on moss stick 1.20 m ht., 5 to 6 s in each pot, well developed with full of fresh & healthy leaves in size of 25 cm Top dia x 18 cm Bottom dia x 25 cm Perpendicular height Earthen pot/Plastic pot & as per direction of the officer-in-charge.
614Providing and stacking of Tecoma gaudichaudi of height 45-60 cm. in earthen pots of size 20 cm as per direction of the officer-in-charge.
615Providing and Displaying Ficus reginold well developed fresh & healthy foliage 60 to 75 cm spread 105 to 120 cm ht., Bushy in 35 cm Cement Pot as per direction of the officer-in-charge.
616Providing and stacking of Bauhinia blakeana (Kachnar) of height 120-150 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
617Providing and stacking of Polyalthia longifolia (Ashok) of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-in-charge.
618Providing and stacking of Ophiopogon jaburan ( variegated ),full of variegated leaves in Earthen Pot/Plastic Pot of size 20 cm. as per direction of the officer-in-charge.
619Providing and stacking of Iresine herbstii, of height 25-30 cm., full of branches well developed in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
620Supplying & Stacking of Selection No.1 doob grass turf at site fresh & free from weeds having proper roots in green including loading, unloading, carriage and all taxes paid etc.and as per direction of officer in charge.
621Providing and displaying of Araucaria cookie having ht. 60 cm to 75 cm, straight, well developed, fresh and healthy with lush green leaves from bottom to top in 20 cm size of Earthen pot/Plastic pot. & as per direction of the officer-in-charge.
622Providing and displaying of Dracaena Song of India (three in one), having ht. 30 cm and above, multibranched, well developed with fresh and healthy leaves in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.
623Providing and Displaying Cyprus golden well shaped developed with good colored foliage fresh & healthy 60 to 75 cm ht in 30 cm Earthen Pot as per direction of the officer-in-charge.
624Providing and stacking of Azadirachta indica ( Neem ) of height 120-130cm in big polybag of size 25 cm as per direction of the officer-in-charge.
625Trees Plant
626Shrubs Plant
627Providing and stacking of Euphorbia caracasana (bronze colour leaves) of height 60-75 cm. with 2-3 branches in earthen pots of size 20 cm as per direction of the officer-in-charge.
628Providing and Displaying Ficus Long Island topiary well developed with fresh & healthy 5 to 6 ball specific size and shape 120 to 150 cm ht in 40 cm Cement Pot as per direction of the officer-in-charge.
629Providing and stacking of Callistemon lanceolatus of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
630Providing and stacking of Caesalpinia pulcherrima species of height 45-60 cm. in earthen pot of size 20 cm as per direction of the officer-in-charge.
631In 75x75 mm deep chase
632Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection >0.70 and initial emittance >0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner.
633With 20 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.7)
634GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.
63512.5 mm thick tapered edge gypsum moisture resistant board.
636GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness60 microns (minimum), including factory painted after bending and perforation and backed with a black Glass fiber acoustical fleece.
637Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
638Size of Tile 600x600 mm
639Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent
64062 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
641Size of Tile 600 x 1200 mm
642Providing and fixing glazed screen printed border tile 75mm wide having thickness 5mm, of approved quality & make, in all shades, design and prints, in dado, over 12mm thick bed of cement mortar1:3 (1 Cement : 3 Coarse sand) and jointing with grey cement slurry @ 3.3 kg/sqm including pointing with white cement mixed with pigment of matching shade, all complete as approved by Engineer - in - Charge.
643Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
644Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete.
645Size of Tile 600 x 600 mm
646Size of Tile 600x600 mm
647Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) 25 mm thick.
648Size of Tile 600 x 1200 mm
649Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
65018 mm thick.
651Size of Tile 600 x 600 mm
652Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles
653Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56282986
AUTHORITY Local Bodies
TENDER VALUE 49.46 Crore
LAST DATE 17-07-2026
Authority
Authority Name Lucknow Development Authority
Work Description Tender for % Construction Of Library Along With Flats (Basement +12) Floors At Nazul Land Located In Birbalsahani Marg, Hasanganj
Basic Detail
Tender No 54/E-Tender/CE/2026-27
Bidding Type Tender
Location
City Lucknow
State Uttar Pradesh
Key Dates
Publish Date 03 Jul 2026
Submission Date 17 Jul 2026
Open Date 18 Jul 2026
Finance
Tender Value 49.46 Crore
Tender Fee 4366
EMD 98.92 Lakhs
Exemption Not Available
Document List
BIDD.pdf
BOQ_2186998.xls
d6ba59f7-0645-4b08-84e6-6102c490b127.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Jul 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
pdf

BIDD.pdf

xls

BOQ_2186998.xls

html

d6ba59f7-0645-4b08-84e6-6102c490b127.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender