Tender For Renovation Of 33/11 Kv 2X10 Mva Chirukandi Dss Under Silchar Electrical Sub-Division-I Within The Jurisdiction Of Cachar Electrical Circle, Apdcl
Tender Value
2.20 Crore
Estimated cost
Bid Submission
20 Jul 2026
6 days left
EMD
5.50 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Cachar → Assam
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Renovation Of 33/11 Kv 2X10 Mva Chirukandi Dss Under Silchar Electrical Sub-Division-I Within The Jurisdiction Of Cachar Electrical Circle, Apdcl
BOQ
| Sl. No. | Item Description |
| 1 | \\"Renovation of 33/11 kV 2x10 MVA Chirukandi DSS under Silchar Electrical Sub-Division-I within the jurisdiction of Cachar Electrical Circle, APDCL\\" Please Enable Macros to View BoQ information |
| 2 | Supply. Fitting and fixing of 11 kV XLPE Cable 1C x 630 sq.mm. |
| 3 | Supply. Fitting and fixing of 1 core 11kv 630 sq mm cable kit indoor type |
| 4 | Supply. Fitting and fixing of 1 core 11kv 630 sq mm cable kit outdoor type |
| 5 | Supply. Fitting and fixing of 11 kV XLPE Cable 3C x 400 sq.mm. |
| 6 | Supply. Fitting and fixing of Jointing Kit for 11 kV XLPE Cable 3C x 400 sq.mm (indoor type) |
| 7 | Supply. Fitting and fixing of Jointing Kit for 11 kV XLPE Cable 3C x 400 sq.mm (outdoor type) |
| 8 | Supply and Installation of 11 kV TPGO-DBCR with earth switch & GI Mounting structure 800Amps |
| 9 | Supply and Installation of 11kV TPGO-DBCR with earth switch & GI Mounting structure 630Amps |
| 10 | Supply and Installation of 33 kV TPGO-DBCR with earth switch and GI Mounting Structure 800 Amps |
| 11 | Supply and Installation of 33 kV 0.5 Class 1ph Outdoor CT with GI mounting structure & marshaling Box (Set comprising of three units) 400-200/1-1A, 25kA for 3 sec |
| 12 | Supply and Installation of 33KV 10KA Lighting Arrestor with Surge Monitor & GI Mounting Structure (Station Type) |
| 13 | Supply and Installation of 33 kV TPGO-DBCR without Earth switch but with GI Mounting Structure 800 Amps |
| 14 | Supply. Fitting and fixing of GI strip 50x6mm for DTR Neutal earthing |
| 15 | Supply and Erection of GI Steel Tubular Pole SP-76 (14.50) |
| 16 | Supply and Erection of GI Steel Tubular Pole SP-66 (12.00) |
| 17 | Supply. Fitting and fixing of GI Channel (100x50x6)mm |
| 18 | Supply. Fitting and fixing of GI Angle (50x50x6)mm |
| 19 | Supply and Stringing of ACSR \\" WOLF\\" Conductor |
| 20 | Supply and Stringing of ACSR \\" RACCON\\" Conductor |
| 21 | Supply. Fitting and fixing of Disc Insulator (Porcelain) 70kN (B&S Type) |
| 22 | Supply. Fitting and fixing of H/W fitting for Disc Insulator T&C 70kN tension type |
| 23 | Supply. Fitting and fixing of Pin Insulator (Polymer) 5KN (FRP 24mm) |
| 24 | Supply. Fitting and fixing of Disc Insulator (Polymeric) 90kN (B&S Type) |
| 25 | Supply. Fitting and fixing of Polymeric Pin Insulator (FRP 34mm) |
| 26 | Supply. Fitting and fixing of Tension clamp for ACSR Wolf |
| 27 | Supply. Fitting and fixing of PG Clamp for ACSR Raccon |
| 28 | Supply. Fitting and fixing of PG Clamp for ACSR Wolf |
| 29 | Supply. Fitting and fixing of LT PVC Cable 4C x 50 sq.mm (Armoured) |
| 30 | Supply. Fitting and fixing of GI Nuts & Bolts with Washer(Assorted) |
| 31 | Supply. Fitting and fixing of 1.1 kV Control Cable 7C x 2.5 sqmm (armoured) |
| 32 | Supply. Fitting and fixing of 1.1 kV Control Cable 10C x 2.5 sqmm (armoured) |
| 33 | Installation of 33 kV TPGO-DBCR with earth switch and GI Mounting Structure 800 Amps |
| 34 | Installation of 33KV VCB 800A with GI Mounting Structure |
| 35 | Installation of 33 kV 0.5 Class 1ph Outdoor CT with GI mounting structure & marshaling Box (Set comprising of three units) 400-200/1-1A, 25kA for 3 sec |
| 36 | Installation of 33KV/110V, 1ph Outdoor PT with GI mounting structure & marshaling Box (Set comprising of three units) |
| 37 | Installation of 33KV 10KA Lighting Arrestor with Surge Monitor & GI Mounting Structure (Station Type) |
| 38 | Installation of 33 kV TPGO-DBCR without Earth switch but with GI Mounting Structure 800 Amps |
| 39 | Installation of Chemical Earthing complete with Gel filled 50mm dia 3 mtrs Copper bonded earthing electrode and 40 Kg Backfilling Compound (MFCE) |
| 40 | Installation of 11KV 10KA Lightning Arrestor (Station Type, Class 2) |
| 41 | Installation of 9 unit 11 kV Indoor type VCB Panel |
| 42 | Dismantling of 11 kV TPGO-DBCR with earth switch & GI Mounting structure 800Amps |
| 43 | Dismantling of 33 kV TPGO-DBCR without Earth switch but with GI Mounting Structure 800 Amps |
| 44 | Dismantling of 33KV VCB 800A with GI Mounting Structure |
| 45 | Dismantling of 33 kV 0.5 Class 1ph Outdoor CT with GI mounting structure & marshaling Box (Set comprising of three units) 400-200/1-1A, 25kA for 3 sec |
| 46 | Dismantling of 33KV/110V, 1ph Outdoor PT with GI mounting structure & marshaling Box (Set comprising of three units) |
| 47 | Dismantling of ACSR \\" WOLF\\" Conductor |
| 48 | Dismantling of ACSR \\" RACCON\\" Conductor |
| 49 | Dismantling of GI Nuts & Bolts with Washer(Assorted) |
| 50 | Dismantling of 11 kV Disc Insulator (Porcelain) 70kN (B&S Type) |
| 51 | Dismantling of H/W fitting for Disc Insulator T&C 70kN tension type |
| 52 | Dismantling of 11 kV Pin Insulator (Polymer) 5KN (FRP 24mm) |
| 53 | Dismantling of 33 kV Disc Insulator (Polymeric) 90kN (B&S Type) |
| 54 | Dismantling of 33 kV Polymeric Pin Insulator (FRP 34mm) |
| 55 | Dismantling of 9 unit 11 kV Indoor type VCB Panel |
| 56 | Grouting & mufflering of steel tubular pole of type SP-66 and SP-76 as per specification and drawing with minimum planting depth of 2.15 m (using PCC) |
| 57 | Earth filling with river sand including watering, leveling, compacting, grading etc. icluding payment of land compensation,forest royalty and other duties as per site condition and technical specification |
| 58 | Switch yard gravelling of 0.15 mtr. (thickness) by 40mm size crushed stone |
| 59 | Construction of RCC switchyard Cable Trenches Size (500x675)mm including trays of MS/GI for cable including supply of all materials and installation of 75 mm RCC slab for cover as per specification and drawing |
| 60 | RCC foundation for 33KV CT or PT |
| 61 | RCC foundation for 33KV Isolator as per standard drawing and technical specifications |
| 62 | RCC foundation for 33KV LA as per standard drawing and technical specifications(per No.) |
| 63 | RCC foundation for VCB |
| 64 | Transformer pad for 10MVA complete as per specification |
| 65 | Increasing of plinth height of control room of 33/11 kV Chirukandi DSS including demolishing of RCC slab & proving PPGI sheet over it, sanitary works and construction of Brick wall drain around the substation (as per BOQ specification) |
| 66 | Laying of interlocking concrete block pavement at 33/11 kV Chirukandi DSS (as per BOQ specification) |
| 67 | Construction of Boundary wall at the 33/11 kV Chirukandi DSS (as per BOQ specification) |
AI Tender Summary
Tender Timeline
Jul 02, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysJul 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender