Tender For Repair And Renovation Of 50 Kld Sewerage Treatment Plant (Stp) That Including Treatment Of Leakage In Reinforced Cement Concrete Tanks By Nipple Grouting, Wall Leakage Treatment With Tile Work, Renovation Of Stp Room Comprising Electrical
Tender Overview
Project Description
Tender for Repair And Renovation Of 50 Kld Sewerage Treatment Plant (Stp) That Including Treatment Of Leakage In Reinforced Cement Concrete Tanks By Nipple Grouting, Wall Leakage Treatment With Tile Work, Renovation Of Stp Room Comprising Electrical Works, Provision Of Aluminium Door, And Painting Work At New Chandigarh, Secretariat Building Sector-9, Chandigarh.(Ch. To. 2215- Non Plan).
BOQ
| Sl. No. | Item Description |
| 1 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : .4.1 |
| 2 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) .4.1.3 |
| 3 | 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) .4.1.10 |
| 4 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). .5.3 |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form for .5.9 |
| 6 | Suspended floors, roofs, landings, balconies and access platform .5.9.3 |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. .5.22 |
| 8 | Thermo-Mechanically Treated bars of grade Fe-500D or more. .5.22.6 |
| 9 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (Size 300mm x 600mm) .8.31 |
| 10 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), ransparent or dyed to required colour or shade, with nuts and screws etc. complete : .9.96 |
| 11 | 300x16 mm .9.96.1 |
| 12 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : .9.97 |
| 13 | 300x10 mm .9.97.1 |
| 14 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : .9.1 |
| 15 | 125 mm .9.100.1 |
| 16 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. .11.37 |
| 17 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : .13.61 |
| 18 | Two or more coats on new work .13.61.1 |
| 19 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. .13.8 |
| 20 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour .13.81 |
| 21 | Old work (one or more coats) .13.81.1 |
| 22 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. .15.23 |
| 23 | For thickness of tiles 10 mm to 25 mm .15.23.1 |
| 24 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. .15.6 |
| 25 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, ie at top. bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately): .21.1 |
| 26 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) .21.1.2 |
| 27 | Anodised aluminium (anodised transparent or dyed to required shade according to IS 1868, Minimum anodic coating of grade AC 15) .21.1.2.1 |
| 28 | Powder coated aluminium (minimum thickness of powder coating 50 micron) .21.1.2.2 |
| 29 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layeror graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architecural drawings and directions of engineer-in-charge. .21.2 |
| 30 | Pre-laminated particle board with decoractive lamination on both sides .21.2.2 |
| 31 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM ruber/neoprene gasket etc. Complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item): .21.3 |
| 32 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) .21.3.2 |
| 33 | Providing and installing 12 mm dia glavanished steel injection nipple in honey comb area and along creack line including drilling of holes of requred diametre (20 mm to 30 mm) up to depth from 30 mm to 80mm at reqired spacing and making the hole & crack dust free by blowing compressed air, sealing he distance between injection nipple with adhesive chemical of approved make and allow it to cure complete as per direction of Engineer-in-charge. .26.39 |
| 34 | E&M DSR 2025 . |
| 35 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. asrequired. .1.1 |
| 36 | Group B . |
| 37 | Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc .as required. .1.4 |
| 38 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. .1.17 |
| 39 | 3 x 1.5 sq. mm .1.17.3 |
| 40 | 3 x 2.5 sq. mm .1.17.12 |
| 41 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. .1.21 |
| 42 | 25 mm .1.21.2 |
| 43 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. .1.24 |
| 44 | 5/6 A switch .1.24.1 |
| 45 | 15/16 A switch .1.24.3 |
| 46 | 3 pin 5/6 A socket outlet .1.24.4 |
| 47 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. .1.25 |
| 48 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. .1.27 |
| 49 | 6 Module (200mmX75mm) .1.27.4 |
| 50 | 12 Module (200mmX150mm) .1.27.6 |
| 51 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. .1.31 |
| 52 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. .1.32 |
| 53 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. .1.33 |
| 54 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : .27.7 |
| 55 | 50 mm dia .27.7.4 |
| 56 | 80 mm dia .27.7.6 |
| 57 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : .27.11 |
| 58 | 80 mm dia .27.11.4 |
| 59 | Providing and laying water proofing coating having three coats of water proofing chemical with 1 coat as primer and 2 subsequent coats. The water proofing chemical shall have properties as water absorption 1% minimum, pot life at 300 C : 30min, application temperature 100 C, bond strength to concrete : approx 1 N/mm2. ( fosroc Hydroproof xtra or equivalent). The primer coat shall be provided in ratio 1 part of Hydroproof xtra :2 parts of water : 4 parts of cement mixed material with the above proportion will cover an area of 16-17 sqm for 1 L of Hydrooproof XTRA. The two top coats shall laid in ratio 1:2 i.e. 1 part of chemical and 2 parts of neat cement after laying of 800 micron fibre mesh. The thickness of each coat shall be about 1 to 2mm. The 2nd coat shall be appiled after 5-6 hours of 1st coat. The full curing shall be done after 12 hours with must curig after 6 hours. The coverage of top coats shall be 4.5.-5.0 sqm/litre/coat. The work shall be undertaken as per manufacturer specifications, complete in all respect and to the entire satisfaction of Engineer in Charge. .NSR |
| 60 | Dismantling of wall tiles from all height including mortar / plaster complete in all respect. .NSR Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender