Tender For Improvement In Water Level Monitoring System Of Ugr And Allied Works At Bindapur Bps, Ac-32.
Tender Overview
Project Description
Tender for Improvement In Water Level Monitoring System Of Ugr And Allied Works At Bindapur Bps, Ac-32.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 06-Jul-2026 | Corrigendum | Date | 09-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling the old and damaged rusted mechanical level indicator at site with the help of gas cutter and heavy manual labour. |
| 2 | Supply/Fabrication of level indicator with Float ball suitable for clear water with 5 mtrs( Approx.) . Providing the anchor with Numeric number plate upto 13 ft. Job includes providing the wire , operating roller wheels for balance between float & anchor. Material required includes MS angle 50X50X6 mm for frame, MS Flat 50 X 5 mm, MS Sheet etc. Work includes making the frame by cutting the MS angle, MS sheet of 1 feet wide and welding the same. Also giving back support with the help of MS flat by cutting, welding, etc. |
| 3 | Installation charges at above BPS with required necessary civil work & hardware goods etc. as required. The Job includes labour charges, transportation charges, hiring charges of T&P items as per site requirement etc. The indication system ( Number Plate) is to be installed inside or Outside Pump house as per site requirement. |
| 4 | Dismantling the old and damaged rusted/CC covers etc. at site with the help of gas cutter and heavy manual labour. |
| 5 | Fabrication and supply of MS UGR cover made out of MS Chequered sheet 4 mm thickness and MS angle 50x50x6 mm with centre support and top side cover duly welded with opening arrangement with heavy duty hinges, handles, etc as per the size of UGR opening |
| 6 | Fixing the above frame with the help of fasteners, CC material and other material required to complete the job i/c T&P items and also fixing the air vent jail on the UGR openings. The job also includes the painting of complete MS frame with the help of red oxide primer and enamel black paint as per site requirement. |
| 7 | Replacement of lighting system by carrying out following works :-Supply of 90 watt energy saving & environmental friendly long life Versatile Pressure die cast aluminium housing LED Street light luminaries complete fittings. Make :-Philips/ Havells/Bajaj/ Crompton/DJB approved makes |
| 8 | Supply of 4X16 sq. mm PVC insulated & PVC sheathed Aluminium armoured conductor cable.Make :-Grandley/Gloster/Havells/CCI/ICC/Universal/DJB approved makes. |
| 9 | Fixing of LED flood light 90 watt fitting on roof of SPS Pump house with the help of MS bracket, drilling on wall & clamping, making connection with 1.5 sq. mm copper conductor wire upto 90 watt LED light, etc as per site requirement. Work i/c arranging all tools & tackles required to complete the job and clamping the 4x16 sq. mm Aluminium armoured cable on the roof wall by taking all safety measures. |
| 10 | Supply of Ceiling fan 1200 mm.Make :-Havells/Bajaj/Crompton/DJB approved makes. |
| 11 | Supply of Air Circulator 600 mm.Make :-Almonard /havells / Crompton/Bajaj /DJB approved makes. |
| 12 | Supply of Heavy Duty Exhaust Fans(900/1440RPM) 300 mm.Make :-Almonard /havells / Crompton/Bajaj /DJB approved makes. |
| 13 | Supply of Higher Wattage Decorative ultra slim aluminum LED lighting fixture with high lumen output, environmental friendly,energy efficient ready to use pack LED tube light 24 W LED 6500 K.Make :- Bajaj/Havells/Cromton/DJB approved makes. |
| 14 | Installation, testing, commissioning of wall bracket / ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. (for LED tube & Air Circulator) |
| 15 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep |
| 16 | Extra for fixing the louvers/ shutters complete with frame for exhaust fan of all sizes. |
| 17 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5sq.mm FRLSPVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 18 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in 292 surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.Group-A |
| 19 | Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2X2.5sq.mm+1 X2.5sq.mm earth wire |
| 20 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 21 | Supplying and fixing metal box of 180mm X100mm X 60mmdeep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 Asocket outlet and 15/16 A piano type switch,connections, painting etc. as required. |
| 22 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way ,Double door |
| 23 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existingMCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 24 | Double pole |
| 25 | Testing & Commissioning of complete work in the presence of Engineer-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
TodayBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
TodayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender