Housing Urban and Rular Development Government Departments Closing in 5 days TDR #56276924

Tender For Construction Of And Improvement Beautification Of Natural Basin At Sammu Tal Tehsil Bhoranj Distt. Hamirpur H.P (Sh- Supply Installation Testing and Commissioning of 16 Meter Long High Mast Light System Thereof)

Issued by Government Departments · Una, Himachal Pradesh
Tender Value
6.49 Lakhs
Estimated cost
Bid Submission
09 Jul 2026
5 days left
EMD
13000
Bank guarantee accepted
Document Fee
350
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Una → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of And Improvement Beautification Of Natural Basin At Sammu Tal Tehsil Bhoranj Distt. Hamirpur H.P (Sh- Supply Installation Testing and Commissioning of 16 Meter Long High Mast Light System Thereof)

BOQ

Name of Work:- Construction of and Improvement Beautification of Natural basin at Sammu Tal Tehsil Bhoranj Distt. Hamirpur H.P (SH- SITC of 16 meter long High Mast light system thereof)
Sl. No. Item Description
1SITC of hot dip galvanised, High Mast Lighting Pole, made of 3mm nominal thick high carbon steel, polygonal section and of following height, along with head frame and movable luminaire carriage to mount up to following nos of fittings, having opening at bottom with vandal proof locking arrangement, power operated double drum winch, 316 grade S.S hoisting ropes, flexible multicore trailing cable, integral power tool motor, manual handle, bolts & nuts, anchor plate & template, lightning finial, aviation light connections to control panel with suitable cabling, etc. complete with supply and fixing the following as per specifications detailed below.The winch should be of motorized & manual type .the capacity of motor 1.5 hp IS: 12615 .Lubrication self in oil bath .The high mast installation shall be capable of withstanding wind speed / wind load as per IS: 875/1987 (Part-III) and erected using foundation bolts on RCC foundation of suitable size as per IS 456 and as per manufacurer's design, with embeded, 75mm dia, B' class GI pipe for cable entry, plastering, finishing including etc. all complete as required (The rate is inclusive of CC foundation as per OEM) Height - 16 mtrs, Bottom - 360 mm,Top - 200 mm with luminaire carriage to mount minimum 9 Nos fittings. Make Bajaj/Surya/Ventura/BPP/Utkarsh/Valmont/Philips as approved by Engineer in charge.
2Supply & erection of outdoor stand mounted feeder pillar 415 v, 16 kw constructed fabricated with 1.6 mm tick crca steel sheet with 4 way terminal for input supply, TPN MCB 32 amp incomer,3pole contactor 30 amp(AC1) for lighting,toggle switch 6 amp for auto manual selection, Timer Digital type, 4 way terminal for output lights ,single pole mcb 10 amp 10 ka , overload relay 2.5 a-4 a, contactor for motor control, 9amp(AC3) ,3 way terminal output for motor, led indicator lights for fwd/reverse ,push switch for motor operation, rotary switch for FWD/REV, pendent box for motor operation, terminal block for 25 sq. mm incomer cable of and 16 & 2.5 sq. mm for out going cables, connections testing and commissioning, etc as required (As per OEM of HM poles) make L&T/Siemens/ Schneider as approved by Eingineer in Charge.
3Supply, Installation, Testing & Commissioning of 250 W +/-10 W Integral LED Floodlight luminaire, tempered glass cover, individual lense over LED ,cradle mounted, Al Pressure Die cast Housing and PC Lens Diifuser having minimum system lumen output 42000 lumens, system lumen efficacy of 120 lm/W with P.F.>0.95 and THD<10% , CRI 70, CCT 5700K. The luminaire shall have IP66 protection, IK10 Protection with availability of narrow and wide beam angles of 60 degree, 22 degree. The LED shall be compliant with Useful L70 life of >50000 Hrs. Driver efficiency should be 85% in input voltage range of 140V to 280V (nominal rated voltage – 240V) with 10 KV internal surge protection. Electrical Insulation Class I. (For Fixing in High Mast Light, 9 nos fitting in each high mast) Make Bajaj/Surya/Ventura/BPP/Utkarsh/Valmont/Philips as approved by Engineer in charge.
4Supplying and testing of following size one number XLPE insulated and PVC sheathed armoured aluminium conductor power cable of 1.1 kV grade conforming to IS 7098 (Part 1) 1988 as required.4 X 16 sq. mm (For High Mast light)
54 X 16 sq. mm (For High Mast light)
62 X 10 sq. mm
7Supplying and fixingMCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator.Make:-L&T /legrand/Hager /Schneider as approved by Engineer-in -charge.
812 way, double door.
9Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-.Make:-L&T /legrand/ Hager /Schneider as approved by Engineer-in -charge.
10Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make:-L&T /legrand/Hager /Schneider as approved by Engineer-in -charge.
1140 Amp, double pole, (single phase and neutral)
12Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make:-L&T /legrand/Hager /Schneider as approved by Engineer-in -charge.
13Single pole.
14Supplying and fixing 32 amps rating, 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of four poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make:-L&T /legrand/Hager/Schneider as approved by Engineer-in -charge.
15Providing, laying and fixing of PVC round sheathed 3 core 2.5 sqmm FRLS copper conductor flexible cable for voltage grade up to 1100 volt , as required complete in all respect. Make :-Finolex/Havell/Polycab/KEI as approved by Engineer in charge.
16Supplying and fixing true power make advanced earthing system having GI pipe 3 meter long 50 mm dia with terminal size 50x6 mm ,internal strip size 25x3 with 50 Kg compound including exvation of pit and refiling the same and making earthing pit cover 12 inch dia as required complete in all respect. make :- make :-True power ,Earth plus,Ashloka as approved Engineer-in -charge.
17Providing and fixing 4.00 mm dia G.I wire on surface or in recess for loop earthing as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56276924
AUTHORITY Government Departments
TENDER VALUE 6.49 Lakhs
LAST DATE 09-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for Construction Of And Improvement Beautification Of Natural Basin At Sammu Tal Tehsil Bhoranj Distt. Hamirpur H.P (Sh- Supply Installation Testing and Commissioning of 16 Meter Long High Mast Light System Thereof)
Basic Detail
Tender No NIT No. 2222-28 dated 24/06/2026
Bidding Type Tender
Location
City Una
State Himachal Pradesh
Key Dates
Publish Date 03 Jul 2026
Submission Date 09 Jul 2026
Open Date 09 Jul 2026
Finance
Tender Value 6.49 Lakhs
Tender Fee 350
EMD 13000
Exemption Not Available
Document List
BOQ_204260.xls
c692b6de-bf41-4ffc-be82-ee6aa3e2346c.html
SBD.pdf
Tendernotice_1.pdf
undertaking.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Jul 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_204260.xls

html

c692b6de-bf41-4ffc-be82-ee6aa3e2346c.html

pdf

SBD.pdf

pdf

Tendernotice_1.pdf

pdf

undertaking.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail