Educational and Research Institute Statutory Bodies & Commissions/Committees Closing in 11 days TDR #56276506

Tender For Purchase Of Electrical Lab Equipments

Issued by Statutory Bodies & Commissions/Committees · Tirunelveli, Tamil Nadu
Tender Value
Ref. Documents
Estimated cost
Bid Submission
16 Jul 2026
11 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tirunelveli → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Purchase Of Electrical Lab Equipments , Single Phase Transformer - Single Phase Transformer, Rating: 1 Kva, 50 Hz, Input: 230 V Ac Output: 115 V Ac Type: Air-Cooled, Single-Phase Step-Down Transformer Properly Insulated Input And Output Terminals Brought Out For Safe Operation , Three Phase Transformer - Type: Three Phase Transformer, Rating: 3 Kva Input Voltage: 415 V Ac, 3-Phase, Output Voltage: 230 V Ac, 3-Phase Frequency: 50 Hz Winding Material: Copper Wound Insulation Class: Class B Or Higher Duty: Continuous Duty Suitable For Laboratory Use Bench/Floor , Load Rheostat Three Phase - Rating: 5.25 Kw, Supply: 415 V Ac, 3-Phase, 50 Hz Total Number Of Load Steps: 6, Main Switch To Be Provided Approximate Dimensions: 18 × 18 × 22 Inches (L × B × H) Comprising Special Cement-Insulated Electrical Load Resistors Mounted On Powder-Coated Ms Panel/Enclosure Individual On/Off Rotary Switches For Load Selection Mounted On Rubber Wheels/Casters For Portability Suitable For Laboratory Load Testing Applications Proper Insulation, Ventilation, And Earthing Arrangement To Be Provided , Three Phase Capacitor Bank - 3-Phase Capacitor Bank Rating: 2 Kvar, Voltage: 440 V Ac, Frequency: 50 Hz Heavy Duty Self-Healing Capacitor Units Powder Coated Ms Enclosure Compact Panel Mounted/Floor Mounted Construction Proper Ventilation Arrangement To Be Provided Capacitor Duty Contactor/Switch To Be Provided Fuse/Mcb Protection To Be Provided Discharge Resistors To Be Provided For Safety Proper Earthing Arrangement Provided , 3 Phase Auto Transformer Starter - 3-Phase Variable Autotransformer Input: 415 V, Output: 0-470 V Ac (Continuous), Current: 15 A Copper Wound, Carbon Brush Type Heavy Duty Toroidal/Core Construction Mounted In Powder Coated Ms/Crca Enclosure Front Panel Mounted Voltage Control Knob With Scale Indication Proper Insulated Terminals Provided Floor/Bench Mounted Type Suitable For Laboratory Use Input/Output Terminal Arrangement Provided Mcb/Fuse Protection Provided Proper Earthing Terminal Provided Ventilation Arrangement For Heat Dissipation , Transformer Oil Bdv Test Kit - Transformer Oil Breakdown Voltage (Bdv) Test Set Input Supply: 230 V Ac, Single Phase, 50 Hz Output Voltage Range: 0-60 Kv Ac Suitable For Testing Dielectric Strength Of Transformer Insulating Oil Oil Test Cup With Standard Electrodes Transparent Safety Hood Provided Over Test Chamber Electrode Gap Adjustable As Per Standard Testing Requirements Interlocking Safety Switch For Hood Protection Automatic Tripping Protection Provided Tripping Current: 10/20 Ma At 2.5 Mm Electrode Gap Ht On Switch With Zero-Voltage Start Facility Sample Transformer Oil To Be Provided With Test Kit.

BOQ

Name of Work:- PURCHASE OF ELECTRICAL LAB EQUIPMENTS
Sl. No. Item Description
1SINGLE PHASE TRANSFORMER - Single Phase Transformer, Rating: 1 kVA, 50 Hz, Input: 230 V acOutput: 115 V acType: Air-cooled, single-phase step-down transformerProperly insulated input and output terminals brought out for safe operation
2THREE PHASE TRANSFORMER - Type: Three Phase Transformer, Rating: 3 kVA Input Voltage: 415 V ac, 3-Phase, Output Voltage: 230 V ac, 3-Phase Frequency: 50 Hz Winding Material: Copper wound Insulation Class: Class B or higher Duty: Continuous duty suitable for laboratory use Bench/Floor
3LOAD RHEOSTAT THREE PHASE - Rating: 5.25 kW, Supply: 415 V ac, 3-Phase, 50 Hz Total Number of Load Steps: 6, Main switch to be provided Approximate dimensions: 18 × 18 × 22 inches (L × B × H) Comprising special cement-insulated electrical load resistors Mounted on powder-coated MS panel/enclosure Individual ON/OFF rotary switches for load selection Mounted on rubber wheels/casters for portability Suitable for laboratory load testing applications Proper insulation, ventilation, and earthing arrangement to be provided
4THREE PHASE CAPACITOR BANK - 3-phase capacitor bank Rating: 2 kVAR, Voltage: 440 V ac, Frequency: 50 Hz Heavy duty self-healing capacitor units Powder coated MS enclosure Compact panel mounted/floor mounted construction Proper ventilation arrangement to be provided Capacitor duty contactor/switch to be provided Fuse/MCB protection to be provided Discharge resistors to be provided for safety Proper earthing arrangement provided
53 Phase Auto transformer starter - 3-phase variable autotransformer Input: 415 V, Output: 0–470 V AC (continuous), Current: 15 A Copper wound, carbon brush type Heavy duty toroidal/core construction Mounted in powder coated MS/CRCA enclosure Front panel mounted voltage control knob with scale indication Proper insulated terminals provided Floor/bench mounted type suitable for laboratory use Input/Output terminal arrangement provided MCB/Fuse protection provided Proper earthing terminal provided Ventilation arrangement for heat dissipation
6Transformer Oil BDV Test Kit - Transformer Oil Breakdown Voltage (BDV) Test Set Input Supply: 230 V ac, Single Phase, 50 Hz Output Voltage Range: 0–60 kV ac Suitable for testing dielectric strength of transformer insulating oil Oil test cup with standard electrodes Transparent safety hood provided over test chamber Electrode gap adjustable as per standard testing requirements Interlocking safety switch for hood protection Automatic tripping protection provided Tripping current: 10/20 mA at 2.5 mm electrode gap HT ON switch with zero-voltage start facility Sample transformer oil to be provided with test kit. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56276506
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 16-07-2026
Authority
Authority Name Directorate Of Technical Education
Work Description Tender for Purchase Of Electrical Lab Equipments , Single Phase Transformer - Single Phase Transformer, Rating: 1 Kva, 50 Hz, Input: 230 V Ac Output: 115 V Ac Type: Air-Cooled, Single-Phase Step-Down Transformer Properly Insulated Input And Output Terminals Brought Out For Safe Operation , Three Phase Transformer - Type: Three Phase Transformer, Rating: 3 Kva Input Voltage: 415 V Ac, 3-Phase, Output Voltage: 230 V Ac, 3-Phase Frequency: 50 Hz Winding Material: Copper Wound Insulation Class: Class B Or Higher Duty: Continuous Duty Suitable For Laboratory Use Bench/Floor , Load Rheostat Three Phase - Rating: 5.25 Kw, Supply: 415 V Ac, 3-Phase, 50 Hz Total Number Of Load Steps: 6, Main Switch To Be Provided Approximate Dimensions: 18 × 18 × 22 Inches (L × B × H) Comprising Special Cement-Insulated Electrical Load Resistors Mounted On Powder-Coated Ms Panel/Enclosure Individual On/Off Rotary Switches For Load Selection Mounted On Rubber Wheels/Casters For Portability Suitable For Laboratory Load Testing Applications Proper Insulation, Ventilation, And Earthing Arrangement To Be Provided , Three Phase Capacitor Bank - 3-Phase Capacitor Bank Rating: 2 Kvar, Voltage: 440 V Ac, Frequency: 50 Hz Heavy Duty Self-Healing Capacitor Units Powder Coated Ms Enclosure Compact Panel Mounted/Floor Mounted Construction Proper Ventilation Arrangement To Be Provided Capacitor Duty Contactor/Switch To Be Provided Fuse/Mcb Protection To Be Provided Discharge Resistors To Be Provided For Safety Proper Earthing Arrangement Provided , 3 Phase Auto Transformer Starter - 3-Phase Variable Autotransformer Input: 415 V, Output: 0-470 V Ac (Continuous), Current: 15 A Copper Wound, Carbon Brush Type Heavy Duty Toroidal/Core Construction Mounted In Powder Coated Ms/Crca Enclosure Front Panel Mounted Voltage Control Knob With Scale Indication Proper Insulated Terminals Provided Floor/Bench Mounted Type Suitable For Laboratory Use Input/Output Terminal Arrangement Provided Mcb/Fuse Protection Provided Proper Earthing Terminal Provided Ventilation Arrangement For Heat Dissipation , Transformer Oil Bdv Test Kit - Transformer Oil Breakdown Voltage (Bdv) Test Set Input Supply: 230 V Ac, Single Phase, 50 Hz Output Voltage Range: 0-60 Kv Ac Suitable For Testing Dielectric Strength Of Transformer Insulating Oil Oil Test Cup With Standard Electrodes Transparent Safety Hood Provided Over Test Chamber Electrode Gap Adjustable As Per Standard Testing Requirements Interlocking Safety Switch For Hood Protection Automatic Tripping Protection Provided Tripping Current: 10/20 Ma At 2.5 Mm Electrode Gap Ht On Switch With Zero-Voltage Start Facility Sample Transformer Oil To Be Provided With Test Kit.
Basic Detail
Tender No 8 / A3 / 2026
Bidding Type Tender
Location
City Tirunelveli
State Tamil Nadu
Key Dates
Publish Date 02 Jul 2026
Submission Date 16 Jul 2026
Open Date 17 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
BOQ_821655.xls
feae4463-f2fb-40ed-a044-0fa04461e6d3.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 02, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Jul 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_821655.xls

html

feae4463-f2fb-40ed-a044-0fa04461e6d3.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders