Drinking Water Supply and Sanitation Government Departments Closing in 23 days TDR #56276099

Tender For Kharak Kalan And Khurd, Dist. Bhiwani, Part 1St :- Dnit For Augmentation Water Supply System In Vill.Kharak,1St Exist.Water Works :Rcc Sands Tank No1,128X140x3.35 Mtr,Rcc S/S Tank No.2,80X150x3.3 Mtr, Reinforced Cement Concrete S/S Tank No

Issued by Government Departments · Bhiwani, Haryana
Tender Value
80.33 Crore
Estimated cost
Bid Submission
28 Jul 2026
23 days left
EMD
1.60 Crore
Bank guarantee accepted
Document Fee
50000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bhiwani → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Kharak Kalan And Khurd, Dist. Bhiwani, Part 1St :- Dnit For Augmentation Water Supply System In Vill.Kharak,1St Exist.Water Works :Rcc Sands Tank No1,128X140x3.35 Mtr,Rcc S/S Tank No.2,80X150x3.3 Mtr, Reinforced Cement Concrete S/S Tank No.3, 120X105x3.35 Mtr.Wtp Of 3.5 Mld,Const.2 No.Cwt.,Const. Of B/W, 2Nd Exist.Water Works :-1 No. Reinforced Cement Concrete S/S Tank 99X 65.5X3.66 Mtr, Exist. Ww Kharak Khurd:-Rcc S/S Tank No1 115X50 X3.96 Mtr .Rcc Ss Tank No.2,70X65x3.96 Mtr.Const.2 No. Cwt .Wtp. Of 1 Mld, Lying Of Pipe Line, Part 2:- detail project report Sewerage System In Stp:- 4.00 Mld Stp, Staff Qtr, P.C. Construction Mps,Pc .Prop.Ips.No.1:-Ct M.Pc .Scr. Chamber 1.22X3.50 Prop. Ips. No.2:-Cwt .Pc .Scr. Chamber 1.22X3.50 .Laying Of Sewer Line, Construction Of Mh, And Restoration And functional house hold tap connection Connections, Rising Mains And Boundary Wall And Cc. Path And Road Etc .P/ Machinery, Electrical Panel, Special Of P/ Machinery .Oandm Cum Defect Liability Period For 6 Year After Successful Completion Of 3 Month Trial Run Period Complete In All Respect. Rs. 8033.83 Lacs

BOQ

Name of Work:- Kharak Kalan and Khurd, Dist. Bhiwani, Part 1st :- DNIT for Aug. Water Supply system in vill.Kharak,1st Exist.Water Works :RCC SandS Tank No1,128x140x3.35 mtr,RCC S/S Tank No.2,80x150x3.3 mtr, RCC S/S Tank No.3, 120x105x3.35 mtr.WTP of 3.5 MLD,Const.2 No.CWT.,Const. of B/W, 2nd Exist.Water Works :-1 No. RCC S/S Tank 99x 65.5x3.66 mtr, Exist. WW Kharak Khurd:-RCC S/S Tank No1 115x50 x3.96 mtr .RCC SS Tank No.2,70x65x3.96 mtr.Const.2 No. CWT .WTP. of 1 MLD, Lying of Pipe Line, Part 2:- DPR Sewerage System in STP:- 4.00 MLD STP, Staff Qtr, P.C. Const. MPS,PC .Prop.IPS.No.1:-CT M.PC .Scr. Chamber 1.22x3.50 Prop. IPS. No.2:-CWT .PC .Scr. Chamber 1.22x3.50 .Laying of Sewer Line, Const. of MH, and Restoration and FHTC Connections, Rising Mains and B/wall and CC. Path and Road etc .P/ Machinery, Elect. Panel, Special of P/ machinery .OandM cum Defect Liability period for 6 year after Successful completion of 3 month trial run period complete in all respect. Rs. 8033.83 lacs
Sl. No. Item Description
1H.S.R. Item
2Provision for Independent Feeder.
3Provision for Providing and fixing CI pipes, Specials and DI Sluice, NRV of required make i.e. IVC /VAG to be installed inside pump chamber for making connection with proposed pumping machinery complete in all respect.
4Supplying, erection, testing and commissioning or Horizontal motor pumping set or Raw Water having head 12.00 m as requirements of discharge in LPM and power capacity in BHP Make: KSEB, CRI, Kirlosker, Crompton Greeve, Lubi)
5Supplying, erection, testing and commissioning of Horizontal motor pumping set for Clear water having head 40. 00 m as per the indicated requirements of discharge in LPM and power capacity in BHP Make: KSB, CRI, Kirtosker, Crompton Greeve, Lubi)
6Less Credit of Old Bricks ( - )
7Credit for Old Pumping Machinery
8Less Credit of Old Steel
9Less credit of old Pumping Machinery ..
10PANEL BOARDS FOR MOTOR: - Supply Erection, Testing and Commissioning of wall mounted electrical LT Panel board, fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size deep having following item for 1 Non clog submercible pumping)START DELTA STARTER :- 1. Main MCCB (ABB/LandT/SCHNEIDER - 01nos2. Controlling MCB - 01nos3.THERMAL OVER LOAD RELAY (ABB/LandT/SCHNEIDER) - 01 nos4. AUXILARY CONTACTOR (ABB/LandT/SCHNEIDER) - 03 nos5. START/STOP PUSH BUTTON (SCHNEIDER/SALZAR/SEIMENS)6. EMERGENCY SWITCH (SCHNEIDER/SALZAR/SEIMENS) - 01 nos7. DIGITAL VAF METER (SECURE/SELEC/TECHNO/ABB) - 01 nos8.CT RATIO - 100/5 (AE/KAPPA/LandT) - 01 nos9. CAPACITOR BANK AS PER LOAD REQUIREMENT10. CHANGE OVER SWITCH AS PER LOAD (SCHNEIDER/SALZAR/SEIMENS) - 01 nos11. SELECTOR SWITCH (SECURE/SELEC/TECHNO/ABB) - 01 nos12. SINGLE PHASE PREVENTER (SECURE/SELEC/TECHNO/ABB) -01 nos13. ELCB BREAKER (ABB/LandT/SCHNEIDER)..10.00 BHP
11(MPS ( MAIN PUMPING STATION ) a) Design, construction, erection, testing and commissioning of MPS and following components: b) RCC Inlet chamber, screening chamber, collecting tank, wet well sump suitable for 4.00 MLD average flow with peak factor 3 including providing and installing 5 No. non clog sewage submersible pump set i.e. 1 No. of 8400 LPM, 2 No. 2800 LPM and 2 No of 1400 LPM having minimum head of 15.00 m. equipped with suitable LT panel board, all safety devices automatic capacitor bank and suitable size submersible cable complete in all respect as per approved NIT. c) K9 DI pipes of suitable dia at MPS including welding and screwing of flanges, ISI marked DI fittings, sluice valves, non returning valves as per requirements even for bye-pass arrangements complete in all respects as per approved NIT. d) 3 No. Cl Gear operated sluice gate with SS spindle (SS 410) and seats (SS304) (2Nos. for screen and 1 No. for partition of collecting tank) as per design complete in all respect as per approved NIT. e) Supply and installation of 2 Nos. mechanical coarse screens suitable for 4.00 MLD average flow with peak factor of 3.0 complete in all respects as per approved NIT: f) All the infrastructure except construction of staff quarter, boundary wall and worked covered under schedule-1A ( HSR-items ) and path ways/roads required to be executed at site to make the MPS functional is included in the scope of work for lump-sump job complete in all respects as per approved NIT. g) All the pumping machinery, panel board, Level sensor etc. shall be controlled by PLC and SCADA and shall be synchronized with PLC panels at MPS and STP site through broadband internet facility. h) The size and quantities of all the above components will be as per approved structural/ Hydraulic/ Mechanical/ Electrical design to be approved by department before actual execution of work complete in all respects as per approved NIT including operation and Maintenance of 5 years after 12 months defect liability period and 3 months trail run period.
12PANEL BOARDS FOR MOTOR: - Supply Erection, Testing and Commissioning of wall mounted electrical LT Panel board, fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size deep having following item for 1 Non clog submercible pumping)START DELTA STARTER :- 1. Main MCCB (ABB/LandT/SCHNEIDER - 01nos2. Controlling MCB - 01nos3.THERMAL OVER LOAD RELAY (ABB/LandT/SCHNEIDER) - 01 nos4. AUXILARY CONTACTOR (ABB/LandT/SCHNEIDER) - 03 nos5. START/STOP PUSH BUTTON (SCHNEIDER/SALZAR/SEIMENS)6. EMERGENCY SWITCH (SCHNEIDER/SALZAR/SEIMENS) - 01 nos7. DIGITAL VAF METER (SECURE/SELEC/TECHNO/ABB) - 01 nos8.CT RATIO - 100/5 (AE/KAPPA/LandT) - 01 nos9. CAPACITOR BANK AS PER LOAD REQUIREMENT10. CHANGE OVER SWITCH AS PER LOAD (SCHNEIDER/SALZAR/SEIMENS) - 01 nos11. SELECTOR SWITCH (SECURE/SELEC/TECHNO/ABB) - 01 nos12. SINGLE PHASE PREVENTER (SECURE/SELEC/TECHNO/ABB) -01 nos13. ELCB BREAKER (ABB/LandT/SCHNEIDER) 2500 LPM x 25 mtr Head = 25 BHP
13Supply of submersible motor pumping set non clog for sewerage having head 25 mtr. As per the indicated requirement of discharge in LPM and power capacity in BHP as per IS mark including all accessories like SS pipe, SS chain, SS foundation bolt, complete base frame, monorail, chain guideline, autocupling, duckfoot band etc. complete in all respec. 2500 LPM x 25 Mtr. Head =50 BHP
14PANEL BOARDS FOR MOTOR: - Supply Erection, Testing and Commissioning of wall mounted electrical LT Panel board, fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size deep having following item for 1 Non clog submercible pumping)START DELTA STARTER :- 1. Main MCCB (ABB/LandT/SCHNEIDER - 01nos2. Controlling MCB - 01nos3.THERMAL OVER LOAD RELAY (ABB/LandT/SCHNEIDER) - 01 nos4. AUXILARY CONTACTOR (ABB/LandT/SCHNEIDER) - 03 nos5. START/STOP PUSH BUTTON (SCHNEIDER/SALZAR/SEIMENS)6. EMERGENCY SWITCH (SCHNEIDER/SALZAR/SEIMENS) - 01 nos7. DIGITAL VAF METER (SECURE/SELEC/TECHNO/ABB) - 01 nos8.CT RATIO - 100/5 (AE/KAPPA/LandT) - 01 nos9. CAPACITOR BANK AS PER LOAD REQUIREMENT10. CHANGE OVER SWITCH AS PER LOAD (SCHNEIDER/SALZAR/SEIMENS) - 01 nos11. SELECTOR SWITCH (SECURE/SELEC/TECHNO/ABB) - 01 nos12. SINGLE PHASE PREVENTER (SECURE/SELEC/TECHNO/ABB) -01 nos13. ELCB BREAKER (ABB/LandT/SCHNEIDER) 5000 LPM x 25 mtr Head = 50 BHP
15Supply of submersible motor pumping set non clog for sewerage having head 25 mtr. As per the indicated requirement of discharge in LPM and power capacity in BHP as per IS mark including all accessories like SS pipe, SS chain, SS foundation bolt, complete base frame, monorail, chain guideline, autocupling, duckfoot band etc. complete in all respec. 5000 LPM x 25 Mt. Head = 50 BHP
16PANEL BOARDS FOR MOTOR: - Supply Erection, Testing and Commissioning of wall mounted electrical LT Panel board, fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size deep having following item for 1 Non clog submercible pumping)START DELTA STARTER :- 1. Main MCCB (ABB/LandT/SCHNEIDER - 01nos2. Controlling MCB - 01nos3.THERMAL OVER LOAD RELAY (ABB/LandT/SCHNEIDER) - 01 nos4. AUXILARY CONTACTOR (ABB/LandT/SCHNEIDER) - 03 nos5. START/STOP PUSH BUTTON (SCHNEIDER/SALZAR/SEIMENS)6. EMERGENCY SWITCH (SCHNEIDER/SALZAR/SEIMENS) - 01 nos7. DIGITAL VAF METER (SECURE/SELEC/TECHNO/ABB) - 01 nos8.CT RATIO - 100/5 (AE/KAPPA/LandT) - 01 nos9. CAPACITOR BANK AS PER LOAD REQUIREMENT10. CHANGE OVER SWITCH AS PER LOAD (SCHNEIDER/SALZAR/SEIMENS) - 01 nos11. SELECTOR SWITCH (SECURE/SELEC/TECHNO/ABB) - 01 nos12. SINGLE PHASE PREVENTER (SECURE/SELEC/TECHNO/ABB) -01 nos13. ELCB BREAKER (ABB/LandT/SCHNEIDER)4000 LPM x 40.00 mtr Head = 60 BHP
17PANEL BOARDS FOR MOTOR: - Supply Erection, Testing and Commissioning of wall mounted electrical LT Panel board, fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size deep having following item for 1 Non clog submercible pumping)START DELTA STARTER :- 1. Main MCCB (ABB/LandT/SCHNEIDER - 01nos2. Controlling MCB - 01nos3.THERMAL OVER LOAD RELAY (ABB/LandT/SCHNEIDER) - 01 nos4. AUXILARY CONTACTOR (ABB/LandT/SCHNEIDER) - 03 nos5. START/STOP PUSH BUTTON (SCHNEIDER/SALZAR/SEIMENS)6. EMERGENCY SWITCH (SCHNEIDER/SALZAR/SEIMENS) - 01 nos7. DIGITAL VAF METER (SECURE/SELEC/TECHNO/ABB) - 01 nos8.CT RATIO - 100/5 (AE/KAPPA/LandT) - 01 nos9. CAPACITOR BANK AS PER LOAD REQUIREMENT10. CHANGE OVER SWITCH AS PER LOAD (SCHNEIDER/SALZAR/SEIMENS) - 01 nos11. SELECTOR SWITCH (SECURE/SELEC/TECHNO/ABB) - 01 nos12. SINGLE PHASE PREVENTER (SECURE/SELEC/TECHNO/ABB) -01 nos13. ELCB BREAKER (ABB/LandT/SCHNEIDER)500 LPM x 35.00 mtr Head = 7.5 BHP
18PANEL BOARDS FOR MOTOR: - Supply Erection, Testing and Commissioning of wall mounted electrical LT Panel board, fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size deep having following item for 1 Non clog submercible pumping)START DELTA STARTER :- 1. Main MCCB (ABB/LandT/SCHNEIDER - 01nos2. Controlling MCB - 01nos3.THERMAL OVER LOAD RELAY (ABB/LandT/SCHNEIDER) - 01 nos4. AUXILARY CONTACTOR (ABB/LandT/SCHNEIDER) - 03 nos5. START/STOP PUSH BUTTON (SCHNEIDER/SALZAR/SEIMENS)6. EMERGENCY SWITCH (SCHNEIDER/SALZAR/SEIMENS) - 01 nos7. DIGITAL VAF METER (SECURE/SELEC/TECHNO/ABB) - 01 nos8.CT RATIO - 100/5 (AE/KAPPA/LandT) - 01 nos9. CAPACITOR BANK AS PER LOAD REQUIREMENT10. CHANGE OVER SWITCH AS PER LOAD (SCHNEIDER/SALZAR/SEIMENS) - 01 nos11. SELECTOR SWITCH (SECURE/SELEC/TECHNO/ABB) - 01 nos12. SINGLE PHASE PREVENTER (SECURE/SELEC/TECHNO/ABB) -01 nos13. ELCB BREAKER (ABB/LandT/SCHNEIDER)4500 LPM x 12.00 mtr Head = 20 BHP
19ANNEXE BUILDING: Construction of HT / LT Panelroom, PLC room, Blower room and Lab cum Office building,Toilet block including doors, windows,finishing, electric, andsanitary fittings complete in all respect as per drawingsapproved by SE. The building will be built up with RCC framestructure and brick work as per specifications mentioned inattached additional documents..
20NS Item -CC TV CAMERAS: Providing and Installing 6 CCTV Cameras (4 Cameras for STP and 2 Cameras for MPS) complete as per satisfaction of the Engineer-In- Charge, within 96 hours of signing the Agreement along with 90 days recording (DVR), 32 inch LED Screen, 16 Channel DVR at STP Site and 8 Channel DVR at MPS Site with connectors, cables, poles and power supply with online real-time output facility. The cameras at both the sites i.e. MPS and STP shall be synchronized at STP site. At STP and MPS Site- 1 No. PTZ speed dome 360 degree 50X zoom camera, 3 No. 12 mm lens size, 1 Nos. 3.6mm lens size.` Make: CP Plus Internet Protocol minimum 5 MP WDR, Night vision color mode 2.4.2 12 mm very focal with extra IR, CCTV Cameras should be installed and commissioned before starting execution of work.
21NS Item -SEWAGE TREATMENT PLANT `Design,construction, erection, testing and commissioning of 4.00 MLD capacity Sewage Treatment Plant based on Sequential Batch Reactor (SBR) Technology complete in all respect including. Landscaping, MCC Panel Room and all other contingent Electrical, Mechanical, Electromagnetic Flow Measurement Device on inlet and outlet, Real Time water quality monitoring with Data collection system (Online analyzer) Piping and Instrumentation works with PLC and SCADA Arrangement for STP and MPS along with Synchronizing it with each otherIncluding furniture and laboratory equipments as per detail given in the bid document and including following components.1. 2 No. High Mast of 9 mtr. GI Octagonal pole of 4 mm thickness (T=100 MM, B=200 MM, Base Plate 320x320x20mm), window at 500 mm from Base Plate)12Nos. Providing and fixing of Solar light 30 watt with dark and motion sensor, 2 level intelligent dimming after 3 and 6 hours of operation, IEC certified solar panel, LM80 certified LED, IP 65 complaint design to protect from rain and dust and UL certified lituimion battery with 2 year system warranty of 6 Mtr. GI pole complete in all respect, along the road and pathcomplete in all respect.2. Supply and installation of 1 No. Main Gate of (MS) 3.65 m wide main gate and 1.25 m wide wicket gate (total weight not less than 500 kg at STP site. As per satisfaction of Engineer in-Charge.3. Providing and installing 2 No. centrifuges (1working plus 1Stand bye) including centrifuge feed pump, all fittings. instrumentations, electric panel board etc. as per design complete in all respect, including packing dry sludge in 20 kg Bag and supplying the same in Market Kisan Sewa Kendra or as directed by Engineer-in-charge within lead as posited as clause 4.4.5 of NIT including operation and maintenance of 5 years after 12 months defect liability and 3 months trail run period...
22Operation and Maintenance for complete scope of work mentioned in the DNIT i.e. 1st and 2nd Existing Water Works WTPs At Kharak Kalan and 1 No. of Existing Water Works At Kharak Khurd, STP, Sewerage Network, 2 No. IPS, Oxidation Pond (Disinfection material supplied by PHED) as per schedule-IV for Operation and Maintenance-cum-defect liability period for 6 years after successful completion of 03 months trial run period will be charged to the A/Mtc. Estimate complete in all respect as per approved NIT. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56276099
AUTHORITY Government Departments
TENDER VALUE 80.33 Crore
LAST DATE 28-07-2026
Authority
Authority Name Public Health Engineering Department
Work Description Tender for Kharak Kalan And Khurd, Dist. Bhiwani, Part 1St :- Dnit For Augmentation Water Supply System In Vill.Kharak,1St Exist.Water Works :Rcc Sands Tank No1,128X140x3.35 Mtr,Rcc S/S Tank No.2,80X150x3.3 Mtr, Reinforced Cement Concrete S/S Tank No.3, 120X105x3.35 Mtr.Wtp Of 3.5 Mld,Const.2 No.Cwt.,Const. Of B/W, 2Nd Exist.Water Works :-1 No. Reinforced Cement Concrete S/S Tank 99X 65.5X3.66 Mtr, Exist. Ww Kharak Khurd:-Rcc S/S Tank No1 115X50 X3.96 Mtr .Rcc Ss Tank No.2,70X65x3.96 Mtr.Const.2 No. Cwt .Wtp. Of 1 Mld, Lying Of Pipe Line, Part 2:- detail project report Sewerage System In Stp:- 4.00 Mld Stp, Staff Qtr, P.C. Construction Mps,Pc .Prop.Ips.No.1:-Ct M.Pc .Scr. Chamber 1.22X3.50 Prop. Ips. No.2:-Cwt .Pc .Scr. Chamber 1.22X3.50 .Laying Of Sewer Line, Construction Of Mh, And Restoration And functional house hold tap connection Connections, Rising Mains And Boundary Wall And Cc. Path And Road Etc .P/ Machinery, Electrical Panel, Special Of P/ Machinery .Oandm Cum Defect Liability Period For 6 Year After Successful Completion Of 3 Month Trial Run Period Complete In All Respect. Rs. 8033.83 Lacs
Basic Detail
Tender No 2026FD16C161 9F62 4B5B ABB6 BAE2B427567A554PUH
Bidding Type Tender
Location
City Bhiwani
State Haryana
Key Dates
Publish Date 02 Jul 2026
Submission Date 28 Jul 2026
Open Date 28 Jul 2026
Finance
Tender Value 80.33 Crore
Tender Fee 50000
EMD 1.60 Crore
Exemption Available
Document List
1A0H9QZ168200.pdf
5d758591-b950-4f14-bb36-8d88ebb738e5.html
BOQ_612178.xls
OT0168200.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 02, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 23 days
Jul 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
pdf

1A0H9QZ168200.pdf

html

5d758591-b950-4f14-bb36-8d88ebb738e5.html

xls

BOQ_612178.xls

pdf

OT0168200.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders