Tender For Kharak Kalan And Khurd, Dist. Bhiwani, Part 1St :- Dnit For Augmentation Water Supply System In Vill.Kharak,1St Exist.Water Works :Rcc Sands Tank No1,128X140x3.35 Mtr,Rcc S/S Tank No.2,80X150x3.3 Mtr, Reinforced Cement Concrete S/S Tank No
Tender Overview
Project Description
Tender for Kharak Kalan And Khurd, Dist. Bhiwani, Part 1St :- Dnit For Augmentation Water Supply System In Vill.Kharak,1St Exist.Water Works :Rcc Sands Tank No1,128X140x3.35 Mtr,Rcc S/S Tank No.2,80X150x3.3 Mtr, Reinforced Cement Concrete S/S Tank No.3, 120X105x3.35 Mtr.Wtp Of 3.5 Mld,Const.2 No.Cwt.,Const. Of B/W, 2Nd Exist.Water Works :-1 No. Reinforced Cement Concrete S/S Tank 99X 65.5X3.66 Mtr, Exist. Ww Kharak Khurd:-Rcc S/S Tank No1 115X50 X3.96 Mtr .Rcc Ss Tank No.2,70X65x3.96 Mtr.Const.2 No. Cwt .Wtp. Of 1 Mld, Lying Of Pipe Line, Part 2:- detail project report Sewerage System In Stp:- 4.00 Mld Stp, Staff Qtr, P.C. Construction Mps,Pc .Prop.Ips.No.1:-Ct M.Pc .Scr. Chamber 1.22X3.50 Prop. Ips. No.2:-Cwt .Pc .Scr. Chamber 1.22X3.50 .Laying Of Sewer Line, Construction Of Mh, And Restoration And functional house hold tap connection Connections, Rising Mains And Boundary Wall And Cc. Path And Road Etc .P/ Machinery, Electrical Panel, Special Of P/ Machinery .Oandm Cum Defect Liability Period For 6 Year After Successful Completion Of 3 Month Trial Run Period Complete In All Respect. Rs. 8033.83 Lacs
BOQ
| Sl. No. | Item Description |
| 1 | H.S.R. Item |
| 2 | Provision for Independent Feeder. |
| 3 | Provision for Providing and fixing CI pipes, Specials and DI Sluice, NRV of required make i.e. IVC /VAG to be installed inside pump chamber for making connection with proposed pumping machinery complete in all respect. |
| 4 | Supplying, erection, testing and commissioning or Horizontal motor pumping set or Raw Water having head 12.00 m as requirements of discharge in LPM and power capacity in BHP Make: KSEB, CRI, Kirlosker, Crompton Greeve, Lubi) |
| 5 | Supplying, erection, testing and commissioning of Horizontal motor pumping set for Clear water having head 40. 00 m as per the indicated requirements of discharge in LPM and power capacity in BHP Make: KSB, CRI, Kirtosker, Crompton Greeve, Lubi) |
| 6 | Less Credit of Old Bricks ( - ) |
| 7 | Credit for Old Pumping Machinery |
| 8 | Less Credit of Old Steel |
| 9 | Less credit of old Pumping Machinery .. |
| 10 | PANEL BOARDS FOR MOTOR: - Supply Erection, Testing and Commissioning of wall mounted electrical LT Panel board, fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size deep having following item for 1 Non clog submercible pumping)START DELTA STARTER :- 1. Main MCCB (ABB/LandT/SCHNEIDER - 01nos2. Controlling MCB - 01nos3.THERMAL OVER LOAD RELAY (ABB/LandT/SCHNEIDER) - 01 nos4. AUXILARY CONTACTOR (ABB/LandT/SCHNEIDER) - 03 nos5. START/STOP PUSH BUTTON (SCHNEIDER/SALZAR/SEIMENS)6. EMERGENCY SWITCH (SCHNEIDER/SALZAR/SEIMENS) - 01 nos7. DIGITAL VAF METER (SECURE/SELEC/TECHNO/ABB) - 01 nos8.CT RATIO - 100/5 (AE/KAPPA/LandT) - 01 nos9. CAPACITOR BANK AS PER LOAD REQUIREMENT10. CHANGE OVER SWITCH AS PER LOAD (SCHNEIDER/SALZAR/SEIMENS) - 01 nos11. SELECTOR SWITCH (SECURE/SELEC/TECHNO/ABB) - 01 nos12. SINGLE PHASE PREVENTER (SECURE/SELEC/TECHNO/ABB) -01 nos13. ELCB BREAKER (ABB/LandT/SCHNEIDER)..10.00 BHP |
| 11 | (MPS ( MAIN PUMPING STATION ) a) Design, construction, erection, testing and commissioning of MPS and following components: b) RCC Inlet chamber, screening chamber, collecting tank, wet well sump suitable for 4.00 MLD average flow with peak factor 3 including providing and installing 5 No. non clog sewage submersible pump set i.e. 1 No. of 8400 LPM, 2 No. 2800 LPM and 2 No of 1400 LPM having minimum head of 15.00 m. equipped with suitable LT panel board, all safety devices automatic capacitor bank and suitable size submersible cable complete in all respect as per approved NIT. c) K9 DI pipes of suitable dia at MPS including welding and screwing of flanges, ISI marked DI fittings, sluice valves, non returning valves as per requirements even for bye-pass arrangements complete in all respects as per approved NIT. d) 3 No. Cl Gear operated sluice gate with SS spindle (SS 410) and seats (SS304) (2Nos. for screen and 1 No. for partition of collecting tank) as per design complete in all respect as per approved NIT. e) Supply and installation of 2 Nos. mechanical coarse screens suitable for 4.00 MLD average flow with peak factor of 3.0 complete in all respects as per approved NIT: f) All the infrastructure except construction of staff quarter, boundary wall and worked covered under schedule-1A ( HSR-items ) and path ways/roads required to be executed at site to make the MPS functional is included in the scope of work for lump-sump job complete in all respects as per approved NIT. g) All the pumping machinery, panel board, Level sensor etc. shall be controlled by PLC and SCADA and shall be synchronized with PLC panels at MPS and STP site through broadband internet facility. h) The size and quantities of all the above components will be as per approved structural/ Hydraulic/ Mechanical/ Electrical design to be approved by department before actual execution of work complete in all respects as per approved NIT including operation and Maintenance of 5 years after 12 months defect liability period and 3 months trail run period. |
| 12 | PANEL BOARDS FOR MOTOR: - Supply Erection, Testing and Commissioning of wall mounted electrical LT Panel board, fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size deep having following item for 1 Non clog submercible pumping)START DELTA STARTER :- 1. Main MCCB (ABB/LandT/SCHNEIDER - 01nos2. Controlling MCB - 01nos3.THERMAL OVER LOAD RELAY (ABB/LandT/SCHNEIDER) - 01 nos4. AUXILARY CONTACTOR (ABB/LandT/SCHNEIDER) - 03 nos5. START/STOP PUSH BUTTON (SCHNEIDER/SALZAR/SEIMENS)6. EMERGENCY SWITCH (SCHNEIDER/SALZAR/SEIMENS) - 01 nos7. DIGITAL VAF METER (SECURE/SELEC/TECHNO/ABB) - 01 nos8.CT RATIO - 100/5 (AE/KAPPA/LandT) - 01 nos9. CAPACITOR BANK AS PER LOAD REQUIREMENT10. CHANGE OVER SWITCH AS PER LOAD (SCHNEIDER/SALZAR/SEIMENS) - 01 nos11. SELECTOR SWITCH (SECURE/SELEC/TECHNO/ABB) - 01 nos12. SINGLE PHASE PREVENTER (SECURE/SELEC/TECHNO/ABB) -01 nos13. ELCB BREAKER (ABB/LandT/SCHNEIDER) 2500 LPM x 25 mtr Head = 25 BHP |
| 13 | Supply of submersible motor pumping set non clog for sewerage having head 25 mtr. As per the indicated requirement of discharge in LPM and power capacity in BHP as per IS mark including all accessories like SS pipe, SS chain, SS foundation bolt, complete base frame, monorail, chain guideline, autocupling, duckfoot band etc. complete in all respec. 2500 LPM x 25 Mtr. Head =50 BHP |
| 14 | PANEL BOARDS FOR MOTOR: - Supply Erection, Testing and Commissioning of wall mounted electrical LT Panel board, fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size deep having following item for 1 Non clog submercible pumping)START DELTA STARTER :- 1. Main MCCB (ABB/LandT/SCHNEIDER - 01nos2. Controlling MCB - 01nos3.THERMAL OVER LOAD RELAY (ABB/LandT/SCHNEIDER) - 01 nos4. AUXILARY CONTACTOR (ABB/LandT/SCHNEIDER) - 03 nos5. START/STOP PUSH BUTTON (SCHNEIDER/SALZAR/SEIMENS)6. EMERGENCY SWITCH (SCHNEIDER/SALZAR/SEIMENS) - 01 nos7. DIGITAL VAF METER (SECURE/SELEC/TECHNO/ABB) - 01 nos8.CT RATIO - 100/5 (AE/KAPPA/LandT) - 01 nos9. CAPACITOR BANK AS PER LOAD REQUIREMENT10. CHANGE OVER SWITCH AS PER LOAD (SCHNEIDER/SALZAR/SEIMENS) - 01 nos11. SELECTOR SWITCH (SECURE/SELEC/TECHNO/ABB) - 01 nos12. SINGLE PHASE PREVENTER (SECURE/SELEC/TECHNO/ABB) -01 nos13. ELCB BREAKER (ABB/LandT/SCHNEIDER) 5000 LPM x 25 mtr Head = 50 BHP |
| 15 | Supply of submersible motor pumping set non clog for sewerage having head 25 mtr. As per the indicated requirement of discharge in LPM and power capacity in BHP as per IS mark including all accessories like SS pipe, SS chain, SS foundation bolt, complete base frame, monorail, chain guideline, autocupling, duckfoot band etc. complete in all respec. 5000 LPM x 25 Mt. Head = 50 BHP |
| 16 | PANEL BOARDS FOR MOTOR: - Supply Erection, Testing and Commissioning of wall mounted electrical LT Panel board, fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size deep having following item for 1 Non clog submercible pumping)START DELTA STARTER :- 1. Main MCCB (ABB/LandT/SCHNEIDER - 01nos2. Controlling MCB - 01nos3.THERMAL OVER LOAD RELAY (ABB/LandT/SCHNEIDER) - 01 nos4. AUXILARY CONTACTOR (ABB/LandT/SCHNEIDER) - 03 nos5. START/STOP PUSH BUTTON (SCHNEIDER/SALZAR/SEIMENS)6. EMERGENCY SWITCH (SCHNEIDER/SALZAR/SEIMENS) - 01 nos7. DIGITAL VAF METER (SECURE/SELEC/TECHNO/ABB) - 01 nos8.CT RATIO - 100/5 (AE/KAPPA/LandT) - 01 nos9. CAPACITOR BANK AS PER LOAD REQUIREMENT10. CHANGE OVER SWITCH AS PER LOAD (SCHNEIDER/SALZAR/SEIMENS) - 01 nos11. SELECTOR SWITCH (SECURE/SELEC/TECHNO/ABB) - 01 nos12. SINGLE PHASE PREVENTER (SECURE/SELEC/TECHNO/ABB) -01 nos13. ELCB BREAKER (ABB/LandT/SCHNEIDER)4000 LPM x 40.00 mtr Head = 60 BHP |
| 17 | PANEL BOARDS FOR MOTOR: - Supply Erection, Testing and Commissioning of wall mounted electrical LT Panel board, fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size deep having following item for 1 Non clog submercible pumping)START DELTA STARTER :- 1. Main MCCB (ABB/LandT/SCHNEIDER - 01nos2. Controlling MCB - 01nos3.THERMAL OVER LOAD RELAY (ABB/LandT/SCHNEIDER) - 01 nos4. AUXILARY CONTACTOR (ABB/LandT/SCHNEIDER) - 03 nos5. START/STOP PUSH BUTTON (SCHNEIDER/SALZAR/SEIMENS)6. EMERGENCY SWITCH (SCHNEIDER/SALZAR/SEIMENS) - 01 nos7. DIGITAL VAF METER (SECURE/SELEC/TECHNO/ABB) - 01 nos8.CT RATIO - 100/5 (AE/KAPPA/LandT) - 01 nos9. CAPACITOR BANK AS PER LOAD REQUIREMENT10. CHANGE OVER SWITCH AS PER LOAD (SCHNEIDER/SALZAR/SEIMENS) - 01 nos11. SELECTOR SWITCH (SECURE/SELEC/TECHNO/ABB) - 01 nos12. SINGLE PHASE PREVENTER (SECURE/SELEC/TECHNO/ABB) -01 nos13. ELCB BREAKER (ABB/LandT/SCHNEIDER)500 LPM x 35.00 mtr Head = 7.5 BHP |
| 18 | PANEL BOARDS FOR MOTOR: - Supply Erection, Testing and Commissioning of wall mounted electrical LT Panel board, fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size deep having following item for 1 Non clog submercible pumping)START DELTA STARTER :- 1. Main MCCB (ABB/LandT/SCHNEIDER - 01nos2. Controlling MCB - 01nos3.THERMAL OVER LOAD RELAY (ABB/LandT/SCHNEIDER) - 01 nos4. AUXILARY CONTACTOR (ABB/LandT/SCHNEIDER) - 03 nos5. START/STOP PUSH BUTTON (SCHNEIDER/SALZAR/SEIMENS)6. EMERGENCY SWITCH (SCHNEIDER/SALZAR/SEIMENS) - 01 nos7. DIGITAL VAF METER (SECURE/SELEC/TECHNO/ABB) - 01 nos8.CT RATIO - 100/5 (AE/KAPPA/LandT) - 01 nos9. CAPACITOR BANK AS PER LOAD REQUIREMENT10. CHANGE OVER SWITCH AS PER LOAD (SCHNEIDER/SALZAR/SEIMENS) - 01 nos11. SELECTOR SWITCH (SECURE/SELEC/TECHNO/ABB) - 01 nos12. SINGLE PHASE PREVENTER (SECURE/SELEC/TECHNO/ABB) -01 nos13. ELCB BREAKER (ABB/LandT/SCHNEIDER)4500 LPM x 12.00 mtr Head = 20 BHP |
| 19 | ANNEXE BUILDING: Construction of HT / LT Panelroom, PLC room, Blower room and Lab cum Office building,Toilet block including doors, windows,finishing, electric, andsanitary fittings complete in all respect as per drawingsapproved by SE. The building will be built up with RCC framestructure and brick work as per specifications mentioned inattached additional documents.. |
| 20 | NS Item -CC TV CAMERAS: Providing and Installing 6 CCTV Cameras (4 Cameras for STP and 2 Cameras for MPS) complete as per satisfaction of the Engineer-In- Charge, within 96 hours of signing the Agreement along with 90 days recording (DVR), 32 inch LED Screen, 16 Channel DVR at STP Site and 8 Channel DVR at MPS Site with connectors, cables, poles and power supply with online real-time output facility. The cameras at both the sites i.e. MPS and STP shall be synchronized at STP site. At STP and MPS Site- 1 No. PTZ speed dome 360 degree 50X zoom camera, 3 No. 12 mm lens size, 1 Nos. 3.6mm lens size.` Make: CP Plus Internet Protocol minimum 5 MP WDR, Night vision color mode 2.4.2 12 mm very focal with extra IR, CCTV Cameras should be installed and commissioned before starting execution of work. |
| 21 | NS Item -SEWAGE TREATMENT PLANT `Design,construction, erection, testing and commissioning of 4.00 MLD capacity Sewage Treatment Plant based on Sequential Batch Reactor (SBR) Technology complete in all respect including. Landscaping, MCC Panel Room and all other contingent Electrical, Mechanical, Electromagnetic Flow Measurement Device on inlet and outlet, Real Time water quality monitoring with Data collection system (Online analyzer) Piping and Instrumentation works with PLC and SCADA Arrangement for STP and MPS along with Synchronizing it with each otherIncluding furniture and laboratory equipments as per detail given in the bid document and including following components.1. 2 No. High Mast of 9 mtr. GI Octagonal pole of 4 mm thickness (T=100 MM, B=200 MM, Base Plate 320x320x20mm), window at 500 mm from Base Plate)12Nos. Providing and fixing of Solar light 30 watt with dark and motion sensor, 2 level intelligent dimming after 3 and 6 hours of operation, IEC certified solar panel, LM80 certified LED, IP 65 complaint design to protect from rain and dust and UL certified lituimion battery with 2 year system warranty of 6 Mtr. GI pole complete in all respect, along the road and pathcomplete in all respect.2. Supply and installation of 1 No. Main Gate of (MS) 3.65 m wide main gate and 1.25 m wide wicket gate (total weight not less than 500 kg at STP site. As per satisfaction of Engineer in-Charge.3. Providing and installing 2 No. centrifuges (1working plus 1Stand bye) including centrifuge feed pump, all fittings. instrumentations, electric panel board etc. as per design complete in all respect, including packing dry sludge in 20 kg Bag and supplying the same in Market Kisan Sewa Kendra or as directed by Engineer-in-charge within lead as posited as clause 4.4.5 of NIT including operation and maintenance of 5 years after 12 months defect liability and 3 months trail run period... |
| 22 | Operation and Maintenance for complete scope of work mentioned in the DNIT i.e. 1st and 2nd Existing Water Works WTPs At Kharak Kalan and 1 No. of Existing Water Works At Kharak Khurd, STP, Sewerage Network, 2 No. IPS, Oxidation Pond (Disinfection material supplied by PHED) as per schedule-IV for Operation and Maintenance-cum-defect liability period for 6 years after successful completion of 03 months trial run period will be charged to the A/Mtc. Estimate complete in all respect as per approved NIT. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 23 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender