Defence Statutory Bodies & Commissions/Committees Closing in 17 days TDR #56276061

Tender For Repair/ Maintenance Of Electric Water Heaters And Rewinding/ Overhauling Of (Ceiling/ Exhaust) Fan And Other Allied Works In Domestic And Technical Area At Air Force Station Jaisalmer

Issued by Statutory Bodies & Commissions/Committees · Barmer, Rajasthan
Tender Value
21 Lakhs
Estimated cost
Bid Submission
23 Jul 2026
17 days left
EMD
42000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Barmer → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Maintenance Of Electric Water Heaters And Rewinding/ Overhauling Of (Ceiling/ Exhaust) Fan And Other Allied Works In Domestic And Technical Area At Air Force Station Jaisalmer

BOQ

Name of Work:- REPAIR/ MAINT OF ELECTRIC WATER HEATERS AND REWINDING/ OVERHAULING OF (CEILING/ EXHAUST) FAN AND OTHER ALLIED WORKS IN DOMESTIC AND TECHNICAL AREA AT AIR FORCE STATION JAISALMER
Sl. No. Item Description
1Taking down the Geyser of any Size/Type/Make from site for repairs/overhauling/replacement of unserviceable parts including replacement of old nuts and bolts with washers heavy duty including disconnection of old nuts and bolts with washers heavy duty including disconnection of electric supply, water supply lines and refixing the geyser in the serviceable condition after assembling,testing and reconnecting the electric/water supply line all as specified and directed. Note :- Replacement of unserviceable parts of old Geyser shall be measured and separately under respective item here in after except bolt, nuts and washers.
2Supply and fix in replacement unserviceable heating element 1.5kw to 2.0 KW of Geyser (ISI marked) for suitable any type/model/make
3Supply and fix in replacement thermostat (ISI Marked) suitable for type, and capacity of geyser complete.
4Supply and fix in replacement of unserviceable door assembly (Appratus plate) ISI marked comprising of inlet and outlet thermostate,housing with gasket with bolts,nuts,washers,screws of packing suitable for any type and make of geyser complete.
5Supply and fix in replacement Stainless steel inner tank 25 ltrs capacity as per exisitng gauge for Geysers complete.
6Supply and fix in replacement Stainless steel inner tank 35 to 50 ltrs capacity as per exisitng gauge for Geysers complete.
7Supply and fix in replacement of outer tank sheet cover made out of MS sheet of suitable size for geyser of 25ltr to 50 ltrs capacity vertical type complete all as specified and directed.
8Supply and proper filling glass wool in between inner and outer tank of geyser complete all as specified and directed.
9Supply and fix in replacement metallic top for 20 Amp capacity complete.
10Supply and fix in replacement metallic plug base for 20 Amp capacity complete.
11Supply and fix in replacement of brass safety valve heavy duty ISI marked of Geyser suitable for 15mm bore of pipe complete.
12Supply and fix in replacement 450mm long PVC pipe connection hot series with both side nut with rubber washer suitable for any capacity of geyser complete.
13Supply and fix in replacement 600mm long PVC pipe connection hot series with both side nut with rubber washer suitable for any capacity of geyser complete.
14S&F in repair CP connection pipes inlet and outlet ( for hot and cold connection) with brass hexagonal adapters both side, suitable for 15mm dia pipe 45cm long all as specified and directed.
15S&F in repair, Non return valve 15/ 20 mm dia made of brass , ISI marked all as specifie and directed.MAKE;-ZOLOTO/VENUS/SANTVALVE
16M & L Spray painting of geyser with one coat of super enamel white paint (berger/Asian/Nerolac) after cleaning of body with detergent powder and writing MES Nos with Black.
17M&L for sheet metal enclosures for DBs when MCBs to be used 2 way SPN complete all as specified and directed.
18M&L for MCB 32 Amp, SPN 'C' series , 240 volt, 50 Hz complete all as specified and directed.
19S & F MCB, 6 to 32 Amp, SP, 240 Volt Make : Legrand /Schneider/Siemens/C&S
20M&L for uPVC pipe of pressure rating 10 Kgf/cm2 fixed complete to walls, ceiling or in floors etc including fittings as bends, elbow, reducer, sockets etc of 15mm dia complete all as specified and directed.
21M&L for uPVC Gate Valve/ Check Valve of size 15mm to 25mm dia complete all as specified and directed.
22S&F in repair 15mm dia stop cock, cast copper alloy chromium plated, screwed down high pressure with capstoan head screwed both ends for iron pipe or union all as specified and directed.MAKE;- SICO/PARYAG/HINDWARE.
23M&L for refixing loose Geysers of any capacity to walls by regrouting of bolts and refixing the Geysers complete with all necessary pipe connection sand making good the disturbed wall surface all as specified and directed.
24S&F three pin plug top 15 Amp suitable for Geyser all as specified and directed.
25Taking down old unserviceable sub main wiring and M&L for submain wiring with 2 single core PVC insulated unsheathed multi stranded copper conductor FRLS wire 2.50 Sq mm 1100 volts grade including and 2.50 Sq mm PVC insulated, multi stranded, unsheathed copper wire green in colour as earthing lead drawn through in PVC conduit incl. Note : Two run of 2.50 Sqmm cable and one run of 2.50 Sqmm cable as earth continuity conductor and 25 mm PVC conduit shall be measured & paid as one unit.
26Taking down old unserviceable sub main wiring and M&L for submain wiring with 2 single core PVC insulated unsheathed multi stranded copper conductor FRLS wire 4.00 Sq mm 1100 volts grade including and 4 Sq mm PVC insulated, multi stranded, unsheathed copper wire green in colour as earthing lead drawn through in PVC conduit incl. Note : Two run of 4.00 Sqmm cable and one run of 4 Sqmm cable as earth continuity conductor and 25 mm PVC conduit shall be measured & paid as one unit.
27Earthing complete with galvanized iron earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the Galvanised iron earth lead wire 4.0 mm dia size, by means nut, bolt, check nuts and washer protected by provision of GI light grade pipe 40mm bore incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced with XPM(weight not less than 4Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point with fixing arrangement CI funnel wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exc 50 mtr all as per electrical plate No.5 of SSR Part I and connecting to earth test point all as specified incl testing on completion.
28Taking down old unserviceable fitting and Supply and fixing cygnus series Recess mounting LED 36 watt 2' x 2' LED Slim Panel - 595x595 mm cat Part No CCR-127-36-57-SL-NWH of make- CG electric or equivalent in philips/Havells/CG/Bajaj white powder coated aluminium extruded housing with LEDs including LED driver and fixing in recess ceiling suitable size of aluminium strip size as required for fixing of LED fitting complete with all accessories prewired fixed on ceiling and connecting up complete with 3 core flexible cable of size 23 / 0.0076 complete all as specified and directed
29S & F in replacement of LED Crystal Wall light Modren style ,5 to 15 watt Complete set ,all as specified and directed.
30S & F in replacement of Modern wall lamp including 7watt LED Bulb complete all as specified and directed.
31Supply, fixing, connecting and testing LED bollard light decorative type with reflector not less than 10 watt as per sample existing at site, IP65 rated Inverted Pyramid Tripod type LED Bollard with soft 360 deg light distribution having fixing arrangements at bottom with necessary nuts, bolts, washers complete in and including taking down of old unserviceable lights complete all as specified and directed, Please Enable Macros to View BoQ information
32Supply, fixing, connecting and testing LED bollard light decorative type with reflector not less than 10 watt as per sample existing at site, IP65 rated Inverted Pyramid Tripod type LED Bollard with soft 360 deg light distribution having fixing arrangements at bottom with necessary nuts, bolts, washers complete in and including taking down of old unserviceable lights complete all as specified and directed, Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56276061
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 21 Lakhs
LAST DATE 23-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Maintenance Of Electric Water Heaters And Rewinding/ Overhauling Of (Ceiling/ Exhaust) Fan And Other Allied Works In Domestic And Technical Area At Air Force Station Jaisalmer
Basic Detail
Tender No 8429/GE/E8
Bidding Type Tender
Location
City Barmer
State Rajasthan
Key Dates
Publish Date 03 Jul 2026
Submission Date 23 Jul 2026
Open Date 25 Jul 2026
Finance
Tender Value 21 Lakhs
Tender Fee 500
EMD 42000
Exemption Available
Document List
8429TENDERDOCU.pdf
BOQ_869152.xls
e321a9d1-5bb4-4369-8f32-832978c62da0.html
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Jul 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
pdf

8429TENDERDOCU.pdf

xls

BOQ_869152.xls

html

e321a9d1-5bb4-4369-8f32-832978c62da0.html

pdf

Tendernotice_1 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail