Defence Statutory Bodies & Commissions/Committees Closing in 11 days TDR #56276053

Tender For Day To Day Maintenance Of Internal Electrification At Otm And Married Accn Including Comprehensive Maintenance Of Cooling Appliances, Repair/ Maintenance Of Ceiling Fan, Exhaust Fan, Pedestal Fan, Geysers And Other Connected Works At insta

Issued by Statutory Bodies & Commissions/Committees · goa, Goa
Tender Value
40 Lakhs
Estimated cost
Bid Submission
22 Jul 2026
11 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
goa → Goa
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Day To Day Maintenance Of Internal Electrification At Otm And Married Accn Including Comprehensive Maintenance Of Cooling Appliances, Repair/ Maintenance Of Ceiling Fan, Exhaust Fan, Pedestal Fan, Geysers And Other Connected Works At installation Mandovi Under Ge (P) Navy Mandovi

BOQ

Name of Work:- DAY TO DAY MAINTENANCE OF INTERNAL ELECTRIFICATION AT OTM AND MARRIED ACCN INCLUDING COMPREHENSIVE MAINTENANCE OF COOLING APPLIANCES, REPAIR/ MAINTENANCE OF CEILING FAN, EXHAUST FAN, PEDESTAL FAN, GEYSERS AND OTHER CONNECTED WORKS AT INS MANDOVI UNDER GE (P) NAVY MANDOVI
Sl. No. Item Description
1COOLING APPLIANCESMaterial & Labour charges for taking out UNSV split AC (outdoor or indoor or both) after disconnecting all necessary connection and re-fixing location as directed complete.Note: Necessary T&P shall be arranged by the contractor for dismantling purpose.
2Material & Labour charges for servicing of split type AC of 1.5/2 TR capacity (outdoor and indoor unit) of any type/size/make/model cleaning and washing of indoor and outdoor unit assembly by chemical and high pressure jet pump, checking, tightening of all electrical connections, replacement of minor spares like nut, bolts, screws, washers (if required ) complete all as specified and directed.Note : (i) Spare parts & gas charging shall be measured & paid seperately under respective items.(ii) Necessary T&P shall be arranged by the contractor for cleaning purpose.
3Material & Labour charges for servicing of water cooler of capacity 40/80 or 60/120 Ltr of any type/make/model and cleaning, washing condenser assembly with high pressure jet pump and cleaning, rubbing and washing storage water tank, draining of dirty water silt, checking, tightening all electrical connections, replacement of minor spares like nut, bolts, screws, washers, drainpipe (if required) complete all as specified and directed.Note :(i) Spare parts & gas charging shall be measured & paid seperately under respective items.(ii) Necessary T&P shall be arranged by the contractor for cleaning purpose.
4Material & Labour charges for servicing of refrigerators of 165 Ltr to 320 Ltr capacity, any type/size/make /model including cleaning, washing condenser assembly with high pressure jet pump, tighening all electrical connections, replacement of minor spares like nut, bolts, screw, washers (if required) complete all as specified and directed.Note :(i) Spare parts & gas charging shall be measured & paid seperately under respective items.(ii) Necessary T&P shall be arranged by the contractor for cleaning purpose.
5Material & Labour charges for testing of refrigerant gas leakage for Split AC 1.5/2.0 TR, Pouring the nitrogen gas flushing to check the leakage in copper pipe lines and brazing by oxyaccetelene gas welding and good quality copper brazing rods or soldering damaged portion, flaring copper pipe, replacement of flare nut, removal of nitrogen gas complete all as specified and directed.
6All as per item No 5 above but for water cooler of any capacity/make/type/model, complete all as specified and directed.
7All as per item No 5 above but for refrigerator of any capacity/make/type/mode/model, complete all as specified and directed.
8All as per item No 5 above but for Deep freezer of any capacity/make/type/mode/model, complete all as specified and directed.
9Note for item no 5,6,7,8 :-Refreirant gas will be measured and paid seprately under relevant itemsNitrogen gas will be paid seperately under relevant items
10Supply and filling of Refrigerant gas R-22/R-32/R-134/R-410 factory sealed cylinder ,complete as specified and directed.
11Supply and filling of Nitrogen gas upto 120 to 300 psi pressure (as required) in cooling appliances complete as specified and directed.
12S & F in repairs metal clad/sheet metal plug and socket with a 3 pin and earth plug and 20 Amps SP MCB including making all connections complete all as specified and directed.
13Labour charges for disconnecting all electrical connection, taking down split type AC of capacity 1.5/2 ton (Indoor & outdoor unit both ) from existing position and refixing the same in new position including necessary cutting opening, fixing, connecting, testing and making good disturbed surface of old position and new position etc complete all as specified and directed.Note : Necessary gas charging, mounting stand drain pipe and copper tube will be paid and measured seperately.
14Taking down and dismantling the unserviceable blower motor from 1.5/2 TR split AC of any type including opening all outer case and rewinding, heat varnishing the blower motor with super enamel copper wire of suitable gauge by taking out burnt winding and cleaning the iron core, complete all as specified and directed.
15All as per item No 13 above but blower motor of water cooler of capacity 40/80 or 60/120 Ltr, complete all as specified and directed.
16S & F in repairs fan motor for indoor unit, single phase 230 Volt, 50 Hz suitable for AC Split type 1.5/2.0 TR, complete all as specified and directed.
17S & F in repair outdoor unit fan motor single phase 230 Volt, 50 Hz suitable for split AC 1.5/2.0 TR capacity, complete all as specified and directed.
18S & F in repair water cooler fan motor single phase 230 Volt, 50 Hz suitable for refrigerator of capacity 40/80 or 60/120 Ltr complete all as specified and directed.
19S & F in repair refrigerator fan motor single phase 230 Volt, 50 Hz suitable for refrigerator of capacity 200 to 310 Ltr, complete all as specified and directed.
20S & F in repair compressor of 1.5/2.0 ton capacity suitable for split type AC of any make/model 1.5/2.0 TR capacity as per existing type complete all as specified and directed.
21All as per item No 19 above but for water cooler 40/80 or 60/120 ltr
22All as per item No 19 above but for refrigerator 165 to 310 ltr
23S & F in repair condensor unit assembly suitable for split AC 1.5 /2 ton capacity, complete all as specified and directed.
24All as per item No 22 above but for water cooler 40/80 or 60/120 ltr
25All as per item No 22 above but for refrigerator 165 to 310 ltr
26S & F in repair PCB of non invertor AC with complete accessories of any make/capacity, complete all as specified and directed.
27Supply & Fixing in repair PCB for outdoor unit of invertor AC model and make as per existing, complete all as specified and directed.
28Supply & Fixing in repair PCB for indoor unit of invertor AC model and make as per existing, complete all as specified and directed.
29M & L for repairing of PCB of all type split AC 1.5/2.0 TR capacity with changes of necessary item as required complete as specified and directed.
30S & F in repair remote control suitable for 1.5/2 ton split type AC as per existing make, complete all as specified and directed.
31S & F in repair overload protector relay as per sample for any type AC of 1.5/2.0 TR capacity of any make/model, complete all as specified and directed.
32All as per item no 30 above but for Water cooler 40/80 or 60/120 Ltr capacity
33All as per item no 30 above but for Refrigerator 165 to 310 Ltr
34All as per item no 30 above but for Deep freezer 200-425 Ltr
35S & F in repair thermostate switch of water cooler suitable for 40/60 or 60/120 ltr capacity complete all as specified and directed.
36All as per item no 34 above but for Refrigerator 165 to 310 Ltr
37All as per item no 34 above but for Deep freezer 200-425 Ltr
38S & F in repair strainer of capillary tube suitable for split AC 1.5/2.0 TR capacity, complete all as specified and directed.
39All as per item no 37 above but for water cooler 40/80 or 60/120 Ltr capacity.
40All as per item no 37 above but for Refrigerator 165 to 310 Ltr
41S & F in repair cooling coil assy suitable for 180 to 310 Ltr capacity refrigerator, complete all as specified and directed.
42S & F in repairs capacitors of the following capacities for ACs/water coolers/ refrigerators complete all as specified and directed.
438 mfd to 30 mfd
4436 mfd to 40 mfd
4545 mfd to 60 Mfd
46Supply & Fixing in repair PVC medium grade 15mm dia drain pipe for split AC as per existing, complete all as specified and directed.
47S & F in repair in repair copper tube 1/4\\", complete all as specified and directed.
48S & F in repair in repair copper tube 1/2\\", complete all as specified and directed.
49S & F in repair in repair copper tube 3/8\\", complete all as specified and directed.
50S & F in repair in repair copper tube 5/8\\", complete all as specified and directed.
51S & F in repair in repair insulation tube 1/4\\", complete all as specified and directed.
52S & F in repair in repair insulation tube 1/2\\", complete all as specified and directed.
53S & F in repair in repair insulation tube 3/8\\", complete all as specified and directed.
54S & F in repair in repair insulation tube 5/8\\", complete all as specified and directed.
55S & F in replacement voltage stabiliser of capacity 5 KVA (single phase), Input voltage range 160 to 280 volt and output 230 volt (+/-1%) complete as specified and directed. Make: V - Guard/ Mirco tech.
56S & F in repair split AC outdoor mounting stand as per existing, complete as specified and directed.
57S & F in repair split AC indoor mounting as per existing, complete as specified and directed.
58S & F in repair Flexible PVC insulated 3 core, 4 Sqmm FR PVC multistranded cables with copper conductor for voltage grade upto 1100 V
59DAY TO DAY MAINTENANCE OF INTERNAL ELECTRIFICATION, CEILING FAN EXHAUST FANTaking down unserviceable point wiring copper or Aluminium (light, fan or Sockets) completely including making good disturbed surfaces all as directed.
60M & L for one point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH of size 1.5 Sq mm single core, including one No. 1.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn in and including PVC casing capping width size not less than 20 mm or as required at site, ISI marked medium grade white colour with all accessories of same grade fixed on wall/ceiling, terminated into and including modular metal flush box, modular cover plate with frame top cover for mounting switches, fan regulators etc for one light/fan point controlled by one 5 Amp switch one way complete all as specified and as directed
61All as per item No. 56 above but for one 5A socket out let on independent board.
62All as per item No. 56 above but for one 5A Socket out let on same board with other switches.
63M & L for point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH of size 2.5 Sq mm single core, including one No. 2.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn in and including PVC Casing & Caping as required at site, ISI marked medium duty, white colour with all accessories of same grade, fixed on wall/ceiling, terminated into and including modular metal flush box, modular cover plate with frame top cover for mounting switches socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type on the independent board complete all as specified and as directed
64S & F in repairs switch socket combinations 3/5 Pin and 5/6 Amp combined flush type.
65S & F in repairs switch socket combination 6 Pin 6 /16 Amp combined flush type.
66S & F in repairs switch piano, flush type single pole one way 5 Amp, 230V complete.
67Supply and fix in repairs ceiling rose 3 terminals, PVC /polycarbonate isolated body with ISI mark.
68S & F in repairs ceiling fan regulator stepped type 120 Watt single phase 230 V.
69S & F in repairs modular Switch single pole one way 6 A, 240 V complete all as specified and as directed
70S & F in repairs modular Switch single pole one way 16 A, 240 V complete all as specified and as directed
71S & F in repairs modular Bell push single pole, one way, 240 V, 6 A complete all as specified and as directed
72S & F in repairs modular Socket outlet 2 in 1, 6 Amp , 240 volts, complete all as specified and as directed
73S & F in repairs modular Socket outlet 5A/16A, 5 in 1, 3 pin, flush type universal, 240 volts complete all as specified and as directed
74S & F in repairs stepped modular electronic fan regulator flush type on the existing board all as directed.
75S & F in repairs MCB 6 to 32 A, Single pole, 240 V, C Series.
76S & F in repairs MCB 32 to 40 A, Single pole neutral, 240 V, C Series.
77S & F in repairs MCB, 4 Pole, 32 to 40 A, 415 V, C-Series.
78S & F in repairs MCB, 4 Pole, 63 Amps 415 V, C Series.
79S & F in repairs LED batten 20 watt including polycarbonate frame and connecting with flexible copper cable of suitable size from ceiling rose to LED batten, The LED fitting duly mounted on PVC block with steel screw & sleeves complete all as specified and directed.MAKE Havells : LED Pride Ultra Batten 20 W 6500 K (Square)
80S & F in repairs LED wall light fitting, 1 x 24 watt, 220V AC, cool white, box type with driver and LED lamp, including connecting with three core flexible copper conductor cable of suitable size from ceiling rose to fitting upto maximium length of 1.5m, complete all as specified and directed.Make: Philips Model No. Ultron3628 Slim LED Wall light cool white ( 24 W) or equivalent as specified in List of Manufacturers.
81S & F in repairs LED batten 10 watt including polycarbonate frame and connecting with flexible copper cable of suitable size from ceiling rose to LED batten, The LED fitting duly mounted on PVC block with steel screw & sleeves complete all as specified and directed.MAKE Havells :LED Pride Ultra Nxt Batten 10 W 6500 K
82Supply & fix in repairs Decorative, wall mounting, brushed nickel finish fixture with Opal Glass diffuser suitable with 9 W LED lamp B22 base including steel screw complete all as specified and directed. Cat part No :Make-Havells, Floretine WL 2LS B22 SS /Philips/Bajaj
83Supply & fix in repairs Decorative, wall mounting, brushed nickel finish fixture with Opal Glass diffuser suitable with 9 W LED lamp B22 base including steel screw complete all as specified and directed. Cat part No :Make-Havells, Floretine WL 1LS B22 SS PPCP /Philips/Bajaj
84Supply & fix in repairs surface/recess mounted LED panel light 1x10 watt, shape round/square type, white powder coated CRCA housing with highpower LEDs, internally prewired, 230 volts 50 hz complete with all accessories such as electronic driver, LED strip,connector block etc. and necessary fixing arrangement at existing/suitable height and removing old unserviceable light complete all as specified and directed .
85Supply & fix in repairs surface/recess mounted LED panel light 2'X2' 36/40 watt, shape square type, white powder coated CRCA housing with highpower LEDs, internally prewired, 230 volts 50 hz complete with all accessories such as electronic driver, LED strip,connector block etc. and necessary fixing arrangement at existing/suitable height and removing old unserviceable light complete all as specified and directed . Havells Cat Part No : LHEBAEP7IW1W036 , 2X2 PANEL 36 W 6500 K Please Enable Macros to View BoQ information
86Supply & fix in repairs surface/recess mounted LED panel light 2'X2' 36/40 watt, shape square type, white powder coated CRCA housing with highpower LEDs, internally prewired, 230 volts 50 hz complete with all accessories such as electronic driver, LED strip,connector block etc. and necessary fixing arrangement at existing/suitable height and removing old unserviceable light complete all as specified and directed . Havells Cat Part No : LHEBAEP7IW1W036 , 2X2 PANEL 36 W 6500 K Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56276053
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40 Lakhs
LAST DATE 22-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Day To Day Maintenance Of Internal Electrification At Otm And Married Accn Including Comprehensive Maintenance Of Cooling Appliances, Repair/ Maintenance Of Ceiling Fan, Exhaust Fan, Pedestal Fan, Geysers And Other Connected Works At installation Mandovi Under Ge (P) Navy Mandovi
Basic Detail
Tender No 8701/E8 GE (P) NAVY MANDOVI
Bidding Type Tender
Location
City goa
State Goa
Key Dates
Publish Date 03 Jul 2026
Submission Date 22 Jul 2026
Open Date 24 Jul 2026
Finance
Tender Value 40 Lakhs
Tender Fee 500
EMD 80000
Exemption Available
Document List
BOQ_869136.xls
c6337ab6-a534-49dc-864d-7288f4ec4e42.html
Tendernotice_1 (2).pdf
TenderPages.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Jul 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_869136.xls

html

c6337ab6-a534-49dc-864d-7288f4ec4e42.html

pdf

Tendernotice_1 (2).pdf

pdf

TenderPages.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders