Tender For Provision Of Geyser, Exhaust Fan, Demolition Of Abandoned/Disused Buildings, Roof Treatment Of Vidyalaya Building And Provn Of Interlocking Blocks At Af Stn Tezpur
Tender Value
44.65 Lakhs
Estimated cost
Bid Submission
21 Jul 2026
13 days left
EMD
89300
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Sonitpur → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of Geyser, Exhaust Fan, Demolition Of Abandoned/Disused Buildings, Roof Treatment Of Vidyalaya Building And Provn Of Interlocking Blocks At Af Stn Tezpur
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of cement concrete in ground floor and pavings n. exc. 15 cm thick (un reinforced) below or above ground level, complete all as specified and directed. |
| 2 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 3 | Removing building materials etc. (other than spoil payable under items 03028 to 03031 in Section-3-Earthwork) to a distance of exc 1.0 km n.exc 5.00 km Load distance beyond the lead included in the rates, including loading, unloading and stacking at the destination etc, complete all as specified and directed. |
| 4 | Dismantling of plain or corrugated galvalume sheeting, any gauge, thickness, including coverings, complete all as specified and directed. |
| 5 | Dismantling of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc complete all as specified and as directed. |
| 6 | Taking down wooden frames with shutter (without taking off shutter from the frame) not exe 1.50 Sqm in each, complete all as specified and directed. |
| 7 | Taking down wooden frames with shutter (without taking off shutter from the frame) exe 1.50 and not exc. 4.00 Sqm each, complete all as specified and directed. |
| 8 | Demolition of reinforced roof, floors (other than ground floors), beams, chajjas and similar suspended work, complete all as specified and directed. |
| 9 | (a) Removing of existing APP membrane on the substrate with using torch machine & heating and mechanicals tools for hacking the surfaces all as specified and directed.(b) Chipping & cleaning of surfaces with the help of wire brush, wash the roof with clean water & remove all loose concrete, grease, oil using wire brush and scrubber all as specified and directed.(c) Providing, mixing and applying polymer modified bond coat of Dr. Fixit, pidicrete URP mix in the ratio of 1:1 (URP 1: Cement 1) by volume to make it lump free slurry when applied on the pre wet surface apply a single coat all as specified and directed.(d) Providing mixing and applying Dr fixit pidicrete URP (301) SBR polymer (@minimum 2% bt wt of cement used) modified cement concrete for structural members with ratio 1:2:3 (ordinary portland cement, coarse sand and graded stone aggregate of 10mm maximum size) with 25mm average thickness all as specified and directed. |
| 10 | (e) Apply one coat of self-primer 1 liter of Dr. Fixit Roof seal Classic (based on acrylate PU Hybrid Elastomeric emulsion technology reinforced with Nano fibers) diluted with 500ml water in the ratio 2:1 spreading at the rate of 0.80-10.0/Sq.mt/ liter in the SSD (Saturate Surface Dry) condition. After 3 hours of primer application, apply 1st coat of Dr.Fixit roof seal classic without dilution spreading at the rate of 0.500/liter/Sq mt/coat until all surface is covered. Allow the first coat to dry for approximately 4-6 hours before applying the 2nd coat at 90 degree to the first coat. Ensure there are no pinholes or air bubbles o the membrane surfaces. Apply second coat of Dr Fixit roof seal classic without dilution spreading at the rate of 0.5 liter/sqmt coat to achieve total dry film thickness of 1.00mm at forced coverage at the rate of 1.00 litre/Sq.mt in 2 coats meet the exceeds the ASTM D 6083-97a standard specification. Attains a Tensile strength of ≥ 2.1 N/mm² with 45 GSM glass fiber mesh confirming to ASM D 412: Elongation at break ≥ 300% and crack bridging ability up to 2mm, Solar Reflectance Index as per ASTM E 1980-106, Air cure the coating for 7 day all as specified and directed. Note: (Any other equivalent approved product in lieu of Dr Fixit may also be used in the work). |
| 11 | M&L for rendering 5mm thick plastering in CM (1:3) on ceiling and finished the plastered surface even and smooth without using extra cement including taking down cement plaster on wall of any description including racking out joints, hacking for key and scrubbing down with water etc and applying three coats of white washing, complete all as specified and directed. |
| 12 | M&L for applying 3 mm wall care putty on surfaces of walls, complete all as per specified and directed. |
| 13 | M & L for rendering 10 mm thick plaster in CM (1:4) on fair faces of brick work or concrete surfaces finish even and fair without using extra cement etc. including racking out joints, hacking for key, scrubbing down with water and including Taking down cement plaster, any description on brick or stone walls, complete all as specified and as directed. |
| 14 | Suply only approved ISI marked integral waterproofing compound, complete all as specified and directed. |
| 15 | M & L for applying new plastered surfaces two coats of acrylic distemper over a coat of primer on prepared 1 mm wall putty surfaces of internal wall all including washing floors, cleaning glass, joinery, electrical fittings, wiring etc., of drops and splashes, complete all as per specified and directed. |
| 16 | Materials and Labour for point wiring with 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing and capping complete with all fittings and accessories, fixed to walls/ceiling, including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet cover (ISI Marked) for mounting switches/ regulator etc and including 1.50 Sq. mm (nominal area) FRLHS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one light/fan point controlled by one switch, complete all as specified and directed. |
| 17 | Supply and fix switch piano, flush button single pole one way 5 Amp, complete all as specified and as directed. |
| 18 | Material and labour ceiling rose, surface bakelite, 65mm x 50mm three terminals, complete all as specified and as directed. |
| 19 | Supply and fix copper winding exhaust fan, steel body AC single Phase. 230V of size 450mm sweep, heavy duty with blades, frame and louvers with all grouting & fasterners including cutting of walls for fixing of exhaust fan and making good the disturbed surface with plaster with CM 1:4, complete all as specified and directed. |
| 20 | Supply and fix copper winding exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with blades, frame and louvers with all grouting & fasterners including cutting of walls for fixing of exhaust fan and making good the disturbed surface with plaster with CM 1:4, complete all as specified and directed by Engr-in-Charge. |
| 21 | Supply and fix exhaust fan made of sturdy Engineering body plastic complete AC single Phase. 230V, 50Hz, RPM 1200 copper winding of 200/250mm sweep, louvers shutters with all grouting & fasterners including cutting of walls for fixing of exhaust fan and making good the disturbed surface with plaster with CM 1:4 complete all as specified and directed. |
| 22 | S&F Geyser 240 volt 2 KW, AC 25 Ltrs capacity BEE 5 star rated with ABS body PUP insulation standing loss in Kwh/24 h/45 degree C 0.465 Kwh with power input 2000 W voltage supply 230 v, 1 phase, 50 Hz, AC incoloy 800 glass coated heating element, Feroglas dry powder coating cold rolled MS water Tank with Hot and Cold connection pipe and complete installation accessories all as specified. |
| 23 | S&F Geyser 240 volt 2 KW, AC 50 Ltrs capacity BEE 5 star rated with ABS body PUP insulation standing loss in Kwh/24 h/45 degree C 0.465 Kwh with power input 2000 W voltage supply 230 v, 1 phase, 50 Hz, AC incoloy 800 glass coated heating element, Feroglas dry powder coating cold rolled MS water Tank with Hot and Cold connection pipe and complete installation accessories all as specified. .Make: Bajaj/Venus/Crompton/Havells/Usha |
| 24 | S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB, 20 Amps, 240V complete all as specified and directed. |
| 25 | Supply and fix for 15 mm bore galvanised steel tubing 'medium grade' (IS-1239) with all fittings, fixed to walls, complete all as specified and as directed. |
| 26 | Supply and fix 15 mm bore Bib tap, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed. |
| 27 | Supply and fixing Stop cock brass 15 mm bore with chromium plated for iron pipe ISI marked with screw end and fancy type, complete all as specified and directed. |
| 28 | Supply and Fix Double Door Sheet Metal Enclosure for DBs for mounting of MCB for 240 Volts, 8 way, with 200 Amps rated bus bar, Single Pole & Neutral, complete all as specified and directed. |
| 29 | Supply and fixing for 240 volts AC factory made doube door MCB DB SPN 4 way including bus bar neutral link, earth bar and din rail, recessed with wall surfaces complete all as specified and as directed. |
| 30 | Supply and fix miniature circuit breaker (MCBs) single pole, 240 Volts, 10KA, 'C' curve, 6 to 32 Amps complete all as specified and directed. |
| 31 | Supply and fix miniature circuit breaker (MCBs) single pole and neutral, 240 Volts, 10KA,'C' curve, 6 to 32 Amps complete all as specified and directed. |
| 32 | Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 1.5. Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn in and including PVC casing & capping and continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 1.5 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring, complete all as specified and directed. |
| 33 | Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 2.5. Sqmm (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn in and including PVC casing & capping and continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 2.5 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring complete all as specified and directed. |
| 34 | Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 4.00 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn in and including PVC casing & capping and continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 4.00 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring, complete all as specified and directed. |
| 35 | Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 6.00 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn in and including PVC casing & capping and continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 6.00 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring, complete all as specified and directed. Materials and Labour for rendering 8 mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 12 mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface in walls, complete all as specified and directed.Note: - (Water proofing compound will be measured and paid separately) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 02, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysJul 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender