Defence Statutory Bodies & Commissions/Committees Closing in 24 days TDR #56276013

Tender For Comprehensive B/R Repair With Water Proofing Treatment To Toilet, Repairs To Roof, Ceiling, Day To Day Maintenance And Other Connected Works At Inhs Patanjali, Amdalli, Mes Area & Site E Of Naval Base Area Karwar.

Issued by Statutory Bodies & Commissions/Committees · Uttara Kannada, Karnataka
Tender Value
6 Lakhs
Estimated cost
Bid Submission
30 Jul 2026
24 days left
EMD
1.15 Lakhs
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Uttara Kannada → Karnataka
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Comprehensive B/R Repair With Water Proofing Treatment To Toilet, Repairs To Roof, Ceiling, Day To Day Maintenance And Other Connected Works At Inhs Patanjali, Amdalli, Mes Area & Site E Of Naval Base Area Karwar.

BOQ

Name of Work:- COMPREHENSIVE B/R REPAIR WITH WATER PROOFING TREATMENT TO TOILET, REPAIRS TO ROOF, CEILING, DAY TO DAY MAINTENANCE AND OTHER CONNECTED WORKS AT INHS PATANJALI, AMDALLI, MES AREA & SITE E OF NAVAL BASE AREA KARWAR.
Sl. No. Item Description
1Demolition of cement Concrete of any description and in any position not otherwise specifically provided as in existing slope roof covering complete all as specified.
2M&L for providing 20mm thick rendering over roof slab when concrete is green in cement mortar (1:3) mixed with water proofing compound @ 2% by weight of cement or as per manufacturers instructions, finished even and smooth surface without using extra cement all as specified and directed. Note: Water proofing compound shall be measured and paid separately.
3Surface preparation: - Preparing the concrete surface to remove dust, dirt, laitance etc using mechanical means and treating minor defects in concrete with polymer modified mortar using - SmartCare repair polymer (SBR).
4Application: Providing and installing SmartCare TPO Membrane Reinforced Membrane or equivalent, is a high performance, heat weldable, scrim reinforced thermoplastic polyolefin (TPO) sheet manufactured & supplied in thickness of 1.5mm as per UNI EN 1849-2, designed for waterproofing and heat shielding roofs of new and existing buildings. The membrane shall have elongation at break >15% as per UNI EN 12311-2 , Hydrostatic Pressure Resistance (6 hrs @5 bar) as per UNI EN 1928 met B ,Tearing Strength (N) >300 as per UNI EN 12310-2, Puncture resistance (mm) of >700 as per DIN 16726-5.12 , Tensile Strength (N/5 cm) is >1100 as per UNI EN 12311-2, the joint of membrane should welded with double seam welding machine and detailing of membrane can be done through hand applied welding tools. The membrane shall be terminated at min height of 300mm above FFL in the vertical areas using termination bar and mechanical fasteners and PU sealant, complete as per manufacturer specifications and product data sheets.
5M&L for applying two coats of smart care damp proof by roller/brush over a coat of primer with smart care damp proof 33% dilution including preparation of existing surface by complete removal of existing treatment by means of chipping the surface to remove loose particles and mortar and clean the surface with wire brush and water wash etc including filling and coving with smart care crack filler of asian paints (wherever required)complete all as per manufacturers instructions ,all as pecified and directed by Engineer-in-charge.
6Taking down wooden shutters of any description n exc 1 sqm each and refixing in the same opening after easing and adjusting and refixing builders hardware as required including renewal of unserviceable screws etc all as directed. Note: (Renewal of any item will be measured and paid seperatly in respective item)
7All as per item No 6 above but exc 1 sqm and n exc 2 sqm each complete all as specified and directed.
8Repairs to wooden shutters by resecuring or easing and adjusting without taking down of shutters of any description not exc 1 sqm each complete all as directed.
9All as per item No 8 above but exc 1 sqm and n exc 2 sqm each complete all as specified and directed.
10Taking down FRP shutters of any description exc 1 sqm & n exc 2 sqm each and refixing in the same opening after easing and adjusting & refixing builder hardware as required including renewal of unserviceable screws all as directed.
11Taking down aluminum window shutter n exc 1 sqm and refixing the same after replacing damaged/ perished/ rusted glass/ gauge/ wire mesh etc complete. (Note-glasss/ gauge/ wire mesh will be measured & paid separetely .
12Taking down aluminum sliding window shutter n exc 1 sqm from track/ tube by removing frame/ track and refixing the same after replacing damaged/ perished/ rusted glass/ gauge/ wire mesh etc complete. (Note- glasss/ gauge/ wire mesh will be measured & paid separetely .
13Taking down aluminium door shutter of size exc 1.5 Sqm and n exc 4 Sqm each leaf, opening floor spring assembly, over hauling, refixing floor spring (with new screws) and door shutter in position all as directed.
14Taking down wooden/ PVC/ FRP/ Aluminium chowkats or frames and not exc.1.5 Sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed.
15All as per item No 14 here in before but exc 1.50 Sqm and n.exc 4 Sqm each complete all as specified and directed.
16M&L for 2nd class hardwood scantlings timber fixed, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered,put together with glue pinned at joints, supplied and fixed, including dismantling wood work all as specified and directed.
17M&L for II class hardwood 35mm thick, framed panelled door shutters (any no of panels) with panels of timber flat on both sides or of veneered particle board medium density wood particle board with commercial face veneers supplied and fitted to chowkats etc complete all as specified and directed.
18M&L for flush shutters 40mm thick, with solid core construction with particle board core and plywood face panels and both sided laminated with decorative face veneers with lipping/ frame to match complete all as specified and directed.
19M&L for mild steel flat iron holdfast for securing new wooden frame and similar articles conforming to FE 290 Gde-E-165 all as specified and directed
20M&L for cement concrete block 1:2:4 type B1 using 20mm graded stone aggregate in holdfast block including necessary formwork etc complete all as specified and directed.
21M&L solid PVC door frame of sizes 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, as per specification and drawings.
22S&F factory made solid PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain coloured PVC “C” channel having a PVC sheet strip of 20mm width stock inside with solvent cement for stiles and plain colour PVC sheet for top rails, lock rails and bottom rails on either side and as gap insert for top rail & bottom rail on either side and as gap insert for top rail and bottom rail, paneling of plain colour of PVC sheet fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement etc. Details as per specification and drawings.
23S&F in repairs for aluminium powder coated anodized minimum thickness of powder coating thick 50 micron frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc including taking down old frames complete all as specified and directed (minimum thickness of powder coating 50 mm)
24S&F in repairs for aluminium powder coated (minimum thickness of powder coated 50 micron) door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified and directed.
25S&F in repairs aluminium powder coated (minimum thickness of powder coated 50 micron) window/ ventilator shutters, sliding type without sash bars, aluminium sections weighing not less than 0.55kg/m including necessary jointing cleats, glazing clips, rubber neoprene packing, aluminium snap beading, screws etc compelte all as specified and directed.
26S&F mild steel butt hinges medium weight, 100mm size complete all as specified and directed.
27S&F 150mm aluminum anodized barrel tower bolts of extruded section complete all as specified and directed.
28S&F extruded aluminum alloy handle fabricated type anodized 150mm complete all as specified and directed.
29S&F in repairs butt hinges 100mm size, medium weight, extruded aluminium alloy with galvanised mild steel hinge pin anodised type C-21 all as specified and directed.
30S&F in repairs butt hinges 125mm size, medium weight, extruded aluminium alloy with galvanised mild steel hinge pin anodised type C-21 all as specified and directed.
31S&F in repairs aluminum alloy, powder coated, sliding door bolt 300 mm long and not less than 12mm dia with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy all as specified and directed.
32S&F in repairs aluminium anodised barrel tower bolts of extruded section 100mm long all as specifed and directed.
33S&F in repairs aluminium anodised barrel tower bolts of extruded section 150mm long all as specified and directed.
34S&F in repairs extruded aluminum anodised handles, fabricated type 150mm size all as directed.
35S&F in repairs aluminium anodised tubular towel rail 19/20mm dia all as specified and directed.
36S&F in repairs, brackets aluminium anodised, suitable for item No.35 herein before complete all as specified and directed.
37S&F in repairs aluminium alloy powder coated curtain rod/ hanger rod 19/20mm dia all as directed.
38S&F in repairs floor door stopper of aluminum alloy body and tongue, anodized with hard drawn steel spring and vulcanised rubber piece fixed in floor, over all length of cover plate 140mm all as specified and directed.
39S&F in repairs aluminium body, door closer, hydraulically regulated designation No.3,universal type,suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 Kg. complete all as specified and directed.
40S&F in repairs mortice locks, brass vertical type size 100mm 4 levers brass chromium plated with keys in duplicate all as specified and directed.
41S&F in repairs aluminium alloy wire cloth, 0.45mm nominal dia of wire & average width of aperture 1.40mm and fixed with aluminium wire staples all as specified and directed. Note : The work is to be carried out above three storey building height.
42Hacking out old broken glass (any thickness, size, quality or description) from wooden frames exc 1.5 sqm, glazed with putty or fixed with beads all as directed. Note: Glass will be measured and paid for separately.
43M&L for 4mm thick sheet glass, ordinary quality and glazing with wooden beading not exc 0.5 Sqm in each pane all as specified and directed.
44M&L for 4mm thick figured glass, pin head type and glazing not exc 0.5 Sqm in each pane with and including wooden beading all as specified and directed.
45M&L for 4.8 mm thick sheet glass, ordinary quality fixed to aluminum frame work and glazing with suitable size aluminum anodised beading exc 0.5 Sqm in each pane including hacking out old broken glass all as specified and directed.
46S&F in repairs veneered particle board 18/19 mm thick, exterior grade, solid core, general purpose type, with face veneers of type BB, fixed with screws to timber frame work all as specified and directed.
47Dismantling boarding, any description, fixed any position fixed with screws complete all as specifed and directed.
48M&L for 18 mm thick PVC ply both sides plain as in cupboards including solvent cement, stainless steel hinges/handles, SS screws etc as per manufactures instructions complete all as specified and directed.
49S&F in repairs stainless steel channels, 50 to 60cm long suitable for moving the drawers complete all as specified and directed
50M&L for 4mm thick non asbestos fibre cemet building boards decorative type fixed/ laid to GI frame work complete all as specified and as directed.
51M&L for GI frame work for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre / intermediate channel 0.9 mm thick having two equal flanges of 15mm each and web of 45 mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section ( not exc 1.2m length) of 0.55 mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre complete including hangers 4 mm dia GI (upto 1200 mm length ) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long complete all as specified and as directed.
52Taking up or down GI tubing 15mm bore and connections, complete all as directed.
53Taking up or down GI tubing 20mm bore and connections, complete all as directed.
54Taking up or down GI tubing 25mm bore and connections, complete all as directed.
55S&F 20 mm dia UPVC pipes of pressure rating 10 Kgf/cm2 fixed complete to walls, ceiling or in floors etc including neccesary fitting (bends/couple/ reducer etc.) complete all as specified and directed.
56S&F 25 mm dia UPVC pipes of pressure rating 10 Kgf/cm2 fixed complete to walls, ceiling or in floors etc including neccesary fitting (bends/couple/ reducer etc.) complete all as specified and directed.
57Refixing old GI tubing 15mm bore and connections in new or old position (walls, ceiling, floors etc), after cleaning from inside, removing rust, cleaning the threads, rethreading all as directed.
58Refixing old GI tubing 20mm bore and connections in new or old position (walls, ceiling, floors etc), after cleaning from inside, removing rust, cleaning the threads, rethreading all as directed.
59S&F tubing 15mm bore medium grade, galvanised, ISI marked with all fitting and fixed complete to walls and ceilings or laid in floors.
60S&F tubing 20mm bore medium grade, galvanised, ISI marked with all fitting and fixed complete to walls and ceilings or laid in floors.
61S&F tubing 25mm bore medium grade, galvanised, ISI marked with all fitting and fixed complete to walls and ceilings or laid in floors.
62S&F in repairs stop valves, cast copper alloy fancy type chromium plated , screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe of 15mm bore all as specified and directed.
63S&F in repairs stop valves, cast copper alloy fancy type chromium plated with long shank and cup (concealed type) for iron pipe of 15mm bore all as specified and directed.
64S&F in repairs angle stop valves, cast copper alloy fancy type chromium plated with long shank and cup (concealed type) for iron pipe of 15mm bore all as specified and directed.
65S&F in repairs bib taps, cast copper alloy fancy type, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe15mm bore all as specified and directed.
66S&F in repairs pillar taps cast copper alloy fancy type chromium plated with capstan heads screwed down high pressure with long screwed shanks and fly nuts, screwed for iron pipe of 15 mm bore all as specified and directed.
67Removal of air lock from GI water pipe line of any dia by loosening socket/bib tap and refixing the same all as directed.
68S&F in repairs 15mm dia, 45 cm long PVC connection with brass ferrules on both ends all as directed.
69S&F in repairs plastic water closet seat and cover, black, closed pattern with flat bottom suitable for pedestal / semi pedestal pattern water closets and mild steel chromium plated or aluminized with hinging device complete all as specified and directed.
70S&F in repairs PVC low level flushing cistern, white 10 litres capacity and connections to pipes all as directed.
71S&F in repairs polythene syphon assembly for PVC low level flushing cistern complete all as directed.
72S&F in repairs 125mm dia brass chromium plated shower rose with swivel joints fancy type suitable for 15mm bore GI pipe all as directed.
73M&L for fixed in repair for 32mm size waste fitting (coupling) brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed all as directed.
74S&F in repairs 32 mm bore PVC waste pipe with fittings of approved make suitable for WHB, Urinals etc all as directed.
75S&F in repairs MS chromium plated grating 125mm dia suitable for Nahani trap all as directed.
76S&F in repair ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe15mm dia( minimum weight 142 gms), suitable for flushing cistern 10 liters capacity all as directed.
77Demolition of cement concrete of any discription and any position all as specified and directed.
78M&L for cement concrete 40mm thick Type B-2,1:2:4 (20mm graded aggregte) in flooring complete all as specified and directed.
79Renewing glazed tiles in patches, area n exc 5 sq.m. including removing and cleaning old tiles, preparing beds and laying or setting, jointing and pointing new or old tiles complete all as specified and directed.
80Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises all as specified and directed by Engineer-in-charge.
81M&L for PCC 25mm thick type 1:2:4, B-0, (12.5mm graded aggregate) as in sub-base to receive floor finishes.
82M&L for non-skid joint free coloured ceramic tiles 7 to 8mm thick, area of each tile exceeding 0.06 Sqm but not exceeding 0.11 sqm, in floors etc set and jointed in neat cement slurry over and including 15mm thick screed bed or bedding layer of cement mortar 1:6 for laying floor finishes.
83M&L for non-skid joint free coloured ceramic tiles 7 to 8mm thick area of each tile exceeding 0.11 Sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry over and including 15mm thick screed bed or bedding layer of cement mortar 1:4 for laying floor finishes.
84All as per item No 83 above but here on vertical surfaces as in skirting/ daddo over and including 10mm thick rendering in CM 1:4 to receive wall finishes.
85M&L for non-skid joint free coloured ceramic tiles 7 to 8mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.36 sqm, in floors etc set and jointed in neat cement slurry over and including 15mm thick screed bed or bedding layer of cement mortar 1:4 for laying floor finishes.
86All as per item No 85 above but here on vertical surfaces as skirting/ daddo over and including 10mm thick rendering in CM 1:4 to receive wall finishes.
87Taking down cement plaster on brick walls etc including raking out joints, hacking for key scrubbing down with water etc compllete all as specified and as directed.
88M&L for rendering 10 mm thick on stone/concrete surfaces to be finished even and smooth (without using extra cement) in CM mortar 1:6 (internal wall surface) complete all as specified and directed.
89M&L for rendering 15 mm thick on stone /concrete surfaces to be finished even and smooth (without using extra cement) in CM mortar 1:4 (external wall surface) including mixing with water proofing compound, complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately.
90Supply only water proofing compound
91M&L for preparation of new plastered surface of internal walls and applying two coats of oil bound distemper by using mechanical spray (maximum working pressure of 3300 PSI) over a coat of primer all as specified and direced
92M&L for preparation of newly plastered external walls and applying two coats of 100% Premium acrylic emulsion paint by using mechanical spray (maximum working pressure of 3300 PSI) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 all as specified and directed.
93M&L for removal of defective tap & extension piece from elbow/socket by cutting/cleaning the threads & replacement of bib tap and extension piece 15mm GI Pipe including making good the floor /wall by replacement of tiles by providing 300x300x7mm thick non skid coloured ceramic tiles set and jointed in near cement slurry and pointed in coloured cement to match laid over 20mm thick cement screed in CM 1:6, area n.exc 0.30 Sqm complete all as specified & directed.
94M&L for removal of blockage in GI pipe 25mm bore by cutting pipe and inserting GI wire or using vaccum pump or any other suitable means and refixing the pipeafter threading and providing all fittings as required, all as directed.Note : The work is to be carried out above two floors height and necessary scaffolding shall be provided by the contractor. The unit rate quoted shall be deemed to including for the same .
95S&F in repairs 600 mm x 450 mm mirror of selected quality glass,mounted on 6mm thick. AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as directed.
96S&F in repairs CI brackets for WHB all as specified and directed.
97S&F in repair wash basins vitreous china , flat back size 550x400 mm white excluding taps,waste chain and plug and porcelain stopper but including barackets all as directed.
98S&F in repair vitreous china semi pedastal pattern (Anglo Indian type ) water closet including pipe,cistern & seat cover complete all as directed.
99S&F in repair vitreous china wash down water closet (pedastal pattern) white, with plastic water closet seat & back with flat bottem and cover, MS chromium plated or aluminium anodised hinge device including fixing bolts and necessary connection with existing pipes etc complete all as directed.
100S&F in repairs sinks made of stainsless steel 1 mm thick with plugs, washers and wastes, including bedding in cement mortor on to dwarf walls or including cantilever brackets and connecting union to pipe overall size 495mmx420mm bowl size 410mm x 330mm x 160mm.
101S&F in repairs PVC handles/knob for low level flushing cistern.
102S&F in repair CP Health faucet with spring pipe as specified
103S&F in repairs brass chromium plated mixing valve suitable for 15mm bore GI pipe including three joints to steel pipes or unions and plugging and screwing to walls all as specified and directed.
104Taking down eaves gutters and rain water pipes (any size or pattern), including all fittings,heads,shoes,bends,swan-necks etc.
105M&L 125mm dia. PVC rain water pipes with Socket all as specified and directed.
106S&F in repairs stack clamps out of 50mm by 5mm including bolts and nuts and securing ends of stay to wall or roof for 100mm pipe all as specified and directed.
107S&F In repair push cock with sprinkler flush for urinal pot completed all as specified and directed.
108S&F in repair vitreous china squatting pan, \\"Orissa pattern\\" size 580x440mm white with integral foot rest (excluding flushing cistern and flushing pipe) and connection with existing pipes etc complete all as directed.
109S&F in repairs chromium plated shower arms 190 mm long .
110S&F in repairs 75 mm dia cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete (1:2:4), type B1 using 20mm graded stone aggregate complete all as specified and directed.
111S&F in repair 20 mm dia ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, ISI marked (Minimum weight 210 gms), screwed & suitable for iron pipe 20 mm bore, complete all as specified.
112M&L for draining out water, cleaning and removing accumulated sludge/dirt scales from tank bottom, side and from moiths of circulating pipes of service tank of including writing date of cleaning in ---DD/MM/YYYY, capacity not exceeding 500 ltrs, located on roof of the building and disinfecting the tank using bleaching powder to make the tank bacteria free complete all as specified and directed.
113M&L for draining out water, cleaning and removing accumulated sludge/dirt scales from tank bottom, side and from mouths of circulating pipes of service tank of including writing date of cleaning in ---DD/MM/YYYY, capacity exceeding 500 ltrs but not exceeding 1000 ltrs, located on roof of the building and disinfecting the tank using bleaching powder to make the tank bacteria free complete all as specified and directed.
114Cleaning and removing all scale and dirt etc. from existing tank exc. 1000 Litres but not not exc. 2000 Litres capacity tanks and from mouths of circulating pipes including writing date of cleaning in ---DD/MM/YYYY-- etc complete all as specified and directed.
115S&F in reapir 15 mm dia gun-metal globe or gate valves, with iron wheel head screwed both ends for iron pipe & fixed in repair, complete all as specified and as directed.
116S&F in repair 20 mm dia gun- metal globe or gate valves, with iron wheel head screwed both ends for iron pipe & fixed in repair, complete all as specified and as directed.
117S&F in repair PVC rotational moulded polythene water storage tanks triple layered (cylindrical vertical with closed top) hoisted and fixed in position all as specifed in SSR part-I (500 ltrs capacity) including dismantling of existing tank.complete all as specified and directed.
118S&F in repair PVC rotational moulded polythene water storage tanks triple layered (cylindrical vertical with 1000 ltrs capacity) including dismantling of existing tank complete all as specified and directed.
119S&F in reapir PVC water tank cover including necessary PVC fixing & locking device fixed with stainless screws suitable for 500/1000 Ltrs water tanks all as specified and directed
120Fixing only in repairs bib taps any type 15mm bore including cleaning and making tap functional all as directed.
121Fixing only in repairs bib taps any type PTMT 15mm bore including cleaning and making tap functional all as directed.
122Fixing only in repairs bib taps any type PTMT 20mm bore including cleaning and making tap functional all as directed.
123Fixing only in repair door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed.
124Fixing only in repair stop valve of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 20mm- 92gms)
125Fixinfg only in repair floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor.
126Fixing only repairs 15 mm dia UPVC pipes to walls/chases/ceilings or laying in floors
127Fixing only repairs 20 mm dia UPVC pipes to walls/chases/ceilings or laying in floors
128Fixing only repairs 25 mm dia UPVC pipes to walls/chases/ceilings or laying in floors
129Fixing only in repairs tubular towel rail, 20mm dia, D type, 60cm long between flange
130Fixing only in repair, seat and cover for pedestal pan including adjusting the cover to its original position, tightening of hinging device using new bolts etc complete all as directed.
131Note for Item No.120 to 130:- Schedule 'B' materials listed will be issued free for fixing for the above items. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56276013
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 6 Lakhs
LAST DATE 30-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Comprehensive B/R Repair With Water Proofing Treatment To Toilet, Repairs To Roof, Ceiling, Day To Day Maintenance And Other Connected Works At Inhs Patanjali, Amdalli, Mes Area & Site E Of Naval Base Area Karwar.
Basic Detail
Tender No 8520/E8
Bidding Type Tender
Location
City Uttara Kannada
State Karnataka
Key Dates
Publish Date 02 Jul 2026
Submission Date 30 Jul 2026
Open Date 01 Aug 2026
Finance
Tender Value 6 Lakhs
Tender Fee 500
EMD 1.15 Lakhs
Exemption Available
Document List
BOQ_868356.xls
ffce1cba-1d92-47a9-a95e-ea870081ab7d.html
TENDER8520.pdf
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 02, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 24 days
Aug 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 26 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_868356.xls

html

ffce1cba-1d92-47a9-a95e-ea870081ab7d.html

pdf

TENDER8520.pdf

pdf

Tendernotice_1 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail