Tender For Special Repair / Replacement Of Normal Fans To Bldc Fans Against Ber At Mil Stn Dhana
Tender Value
9.71 Lakhs
Estimated cost
Bid Submission
23 Jul 2026
8 days left
EMD
19424
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Sagar → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair / Replacement Of Normal Fans To Bldc Fans Against Ber At Mil Stn Dhana
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 11-Jul-2026 | AMENDMENTS TO TENDER DOCUMENTS | Other | 23-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully point wiring of any type/size (Light, fan, socket ) complete including making good the disturb surface finishing of wall /floor etc,complete all as specified and directed. |
| 2 | Taking down existing sub main wiring of any type/size complete from wall and making good distrubed surface complete all as specified and directed. |
| 3 | Material & labour for point wiring with 1.5 Sqmm PVC FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC Casing and capping of suitable size as per site reqmt, ISI marked medium grade with all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc all as per site requirements including concealed pressed steel terminal boxes for mounting of switches/ sockets/regulator etc duly coated with a one coat of black bituminous paint over a coat of red oxide primer and 3 mm thick industrial type hylum sheet and PVC FRLS insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead connected to common earth dolly complete all as specified and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green. (a) For one light point/fan Point controlled by one way switch. |
| 4 | All as per item No 3 above but for 5 Amp socket outlet on the same board controlled by one 5 Amps switch one way complete. |
| 5 | All as per item No 3 here-in-before but for power point wiring with 2.5 Sqmm FRLS PVC insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 Sqmm FRLS PVC insulated, unsheathed, copper conductor, stranded 1100 volt grade cable for earth continuity. |
| 6 | Material and labour for sub main wiring with 2 x 4 Sq mm PVC insulated single core unsheathed stranded copper conductor drawn in and including PVC conduit pipe of suitable size ISI marked including continuous running earth wire by 4 Sqmm PVC unsheathed single core stranded copper conductor connected to common earth dolly including plastic terminal boxes completed all as specified and directed by Engr in Charge. |
| 7 | Supply and fixing switch piano flush type 5 Amp single pole, one way all as specified and directed by Engr in charge. |
| 8 | Supply and fixing switch socket combination 5 in 1, 6 pin, 5 Amp, flush type universal, 240 V complete all as specified and directed by Engr in charge. |
| 9 | Supply and fixing switch socket combination 5 in 1, 6 pin, 5/16 Amp, flush type universal, 240 V complete all as specified and directed by Engr in charge. |
| 10 | Supply and fixing in repair ceiling rose surface bakelite 65 x 50 mm three terminal complete all as specified and directed by Engr in charge. |
| 11 | Supply and Fixing MCB DB single door SPN 2 way, 240 Volt complete all as specified and directed by Engr in charge. |
| 12 | Supply and Fixing MCB SPN 32 Amps, 240 Volts, C Curve with breaking capacity 10 KA complete all as specified and directed by Engr in charge. |
| 13 | Supply & fix ceilling fan complete with blades, down rods, electronic regulator and accessories, 230 volt, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE 5 Star rated with brushless direct current motor (BLDC) complete all as specified and directed by Engr in Charge. Note : Old u/s existing ceiling fan any size any make should be deposited in E/M store yard for BER disposal. |
| 14 | Supply & fix exhaust fan, steel body AC single phase 230 volt of size 300 mm sweep with blades and frame and louver complete including making hole if not available at site complete all as specified and directed by Engr in charge. Note : Old u/s existing Exhaust fan any size any make should be deposited in E/M store yard for BER disposal. |
| 15 | Supply and fix in replacment of electric water heater storage type steel body with glasslead inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 star rated complete with all accessories such as safety valve, thermostate, NRV connection pipe complete all as specified and directed by Engr in Charge. Note : Old u/s water heater any size any make should be deposited in E/M store yard for BER disposal. |
| 16 | NOTE :- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs 1678.00/- ] Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 11, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Jul 23, 2026
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 8 daysJul 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender