Tender for Repair / Maintenance Of Electrical Distribution System And Other Allied Works At Site C, Mes Complex, Milan Nagar, 3 Afsr Under Ge (Af) Borjhar
BOQ
| Sl. No. | Item Description |
| 1 | Excavating in trenches manually not exceeding 1.5m wide and not exceeding1.5 mtr in depth/ width for laying under ground cable / foundations and getting out in soft / loose soil all as specified and directed. Note: During excavation no mechanical excavator is permitted at site, contractor will do the excavation through manually. |
| 2 | Returning, filling in incl spreading, leveling, watering and well ramming in layers not exceeding 25cm all as specified and directed. |
| 3 | Removing of surplus excavating material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed. |
| 4 | M&L for cement concrete in foundations, filling and mass concreteType C2 1:3:6, 40mm graded aggregate all as specified and directed. |
| 5 | M&L for PCC as in foundation or any other works type B1 (1:2:4) (20mm graded aggregate) all as specified and directed. Note:- Any form work required for PCC works are deemed to be included in this rate. |
| 6 | M&L rendering 10mm thick in CM 1:6 on fair faces of brick works or concrete surfaces all as specified and directed. |
| 7 | M&L for taking out of old/ unsv cable of any sizes or types for replacement with new one complete all as specified & directed. |
| 8 | M&L for relaying heavy duty LT under ground cable of any sizes and types in pipe /trench /cable duct /fixed on wall by proper size shaped GI clamps with nut bolts etc and making good the disturbed surfaces by cement mortar/paint to match with the existing surface complete all as specified & directed. |
| 9 | M&L for LT Cable fault detection and its rectification by using Cable fault locator machine of span length varying from 50 RM to 600 RM of cable size 95 to 400 sqmm all as specified and and directed by Engr-in-Charge. Note:-1. Suitable excavation and jointing kit will be measured and paid seperately. |
| 10 | S&F UG cable XLPE insulated,armoured heavy duty electric cable with aluminium conductor,1100 Volts grade,cross section area incl taking down of size 300 sq mm 3.5 core complete all as directed. |
| 11 | All as per item no.10 above but size 240 sqmm 3.5 core complete all as directed. |
| 12 | All as per item no.10 above but size 185 sqmm 3.5 core complete all as directed. |
| 13 | All as per item no.10 above but size 150 sqmm 3.5 core complete all as directed. |
| 14 | All as per item no.10 above but size 95 sqmm 3.5 core complete all as directed. |
| 15 | All as per item no.10 above but size 70 sqmm 3.5 core complete all as directed. |
| 16 | All as per item no.10 above but size 50 sqmm 3.5 core complete all as directed. |
| 17 | All as per item no.10 above but size 25 sqmm 3.5 core complete all as directed. |
| 18 | All as per item no.10 above but size 16 sqmm 4 core complete all as directed. |
| 19 | All as per item no.10 above but size 10 sqmm 2 core complete all as directed. |
| 20 | M&L for boring under roads or any other specified location by reqd T&P without disturbing the top surface of the road for insertion of GI Pipe of 50 to 100 mm dia etc complete all as specified and directed. |
| 21 | M&L for HDPE Double wall corrugated pipe of size 110/95 mm as per IS: 16098 Part-II-2013 and ISO 21138 & BSEN 13476-1TO 3 laid in trenches/wall for protection cables complete all as specified and directed. |
| 22 | M&L for tubes 50 mm bore light grade galvanized with all fittings laid in trenches/ wall/ pole through MS flat (25X3 mm), nut, bolt & washers [ where ever reqd ] of proper sizes for protection cables complete all as specified and directed. |
| 23 | All as per above item no.24 but bore size 40 mm complete all as directed. Please Enable Macros to View BoQ information |
| 24 | All as per above item no.24 but bore size 40 mm complete all as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 02, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysJul 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender