Defence Statutory Bodies & Commissions/Committees Closing in 15 days TDR #56275963

Tender For Repair / Maintenance Of Electrical Distribution System And Other Allied Works At Site C, Mes Complex, Milan Nagar, 3 Afsr Under Ge (Af) Borjhar

Issued by Statutory Bodies & Commissions/Committees · Kamrup Metro, Assam
Tender Value
Ref. Documents
Estimated cost
Bid Submission
23 Jul 2026
15 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kamrup Metro → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair / Maintenance Of Electrical Distribution System And Other Allied Works At Site C, Mes Complex, Milan Nagar, 3 Afsr Under Ge (Af) Borjhar

BOQ

Name of Work:- REPAIR / MAINT OF ELECTRICAL DISTRIBUTION SYSTEM AND OTHER ALLIED WORKS AT SITE C, MES COMPLEX, MILAN NAGAR, 3 AFSR UNDER GE (AF) BORJHAR
Sl. No. Item Description
1Excavating in trenches manually not exceeding 1.5m wide and not exceeding1.5 mtr in depth/ width for laying under ground cable / foundations and getting out in soft / loose soil all as specified and directed. Note: During excavation no mechanical excavator is permitted at site, contractor will do the excavation through manually.
2Returning, filling in incl spreading, leveling, watering and well ramming in layers not exceeding 25cm all as specified and directed.
3Removing of surplus excavating material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed.
4M&L for cement concrete in foundations, filling and mass concreteType C2 1:3:6, 40mm graded aggregate all as specified and directed.
5M&L for PCC as in foundation or any other works type B1 (1:2:4) (20mm graded aggregate) all as specified and directed. Note:- Any form work required for PCC works are deemed to be included in this rate.
6M&L rendering 10mm thick in CM 1:6 on fair faces of brick works or concrete surfaces all as specified and directed.
7M&L for taking out of old/ unsv cable of any sizes or types for replacement with new one complete all as specified & directed.
8M&L for relaying heavy duty LT under ground cable of any sizes and types in pipe /trench /cable duct /fixed on wall by proper size shaped GI clamps with nut bolts etc and making good the disturbed surfaces by cement mortar/paint to match with the existing surface complete all as specified & directed.
9M&L for LT Cable fault detection and its rectification by using Cable fault locator machine of span length varying from 50 RM to 600 RM of cable size 95 to 400 sqmm all as specified and and directed by Engr-in-Charge. Note:-1. Suitable excavation and jointing kit will be measured and paid seperately.
10S&F UG cable XLPE insulated,armoured heavy duty electric cable with aluminium conductor,1100 Volts grade,cross section area incl taking down of size 300 sq mm 3.5 core complete all as directed.
11All as per item no.10 above but size 240 sqmm 3.5 core complete all as directed.
12All as per item no.10 above but size 185 sqmm 3.5 core complete all as directed.
13All as per item no.10 above but size 150 sqmm 3.5 core complete all as directed.
14All as per item no.10 above but size 95 sqmm 3.5 core complete all as directed.
15All as per item no.10 above but size 70 sqmm 3.5 core complete all as directed.
16All as per item no.10 above but size 50 sqmm 3.5 core complete all as directed.
17All as per item no.10 above but size 25 sqmm 3.5 core complete all as directed.
18All as per item no.10 above but size 16 sqmm 4 core complete all as directed.
19All as per item no.10 above but size 10 sqmm 2 core complete all as directed.
20M&L for boring under roads or any other specified location by reqd T&P without disturbing the top surface of the road for insertion of GI Pipe of 50 to 100 mm dia etc complete all as specified and directed.
21M&L for HDPE Double wall corrugated pipe of size 110/95 mm as per IS: 16098 Part-II-2013 and ISO 21138 & BSEN 13476-1TO 3 laid in trenches/wall for protection cables complete all as specified and directed.
22M&L for tubes 50 mm bore light grade galvanized with all fittings laid in trenches/ wall/ pole through MS flat (25X3 mm), nut, bolt & washers [ where ever reqd ] of proper sizes for protection cables complete all as specified and directed.
23All as per above item no.24 but bore size 40 mm complete all as directed. Please Enable Macros to View BoQ information
24All as per above item no.24 but bore size 40 mm complete all as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56275963
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 23-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Maintenance Of Electrical Distribution System And Other Allied Works At Site C, Mes Complex, Milan Nagar, 3 Afsr Under Ge (Af) Borjhar
Basic Detail
Tender No 8581/BOR/E8
Bidding Type Tender
Location
City Kamrup Metro
State Assam
Key Dates
Publish Date 02 Jul 2026
Submission Date 23 Jul 2026
Open Date 27 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 70000
Exemption Available
Document List
9c5477da-2a52-4819-81cb-1da529cd1241.html
BOQ_869058.xls
tender8581.pdf
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 02, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Jul 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
html

9c5477da-2a52-4819-81cb-1da529cd1241.html

xls

BOQ_869058.xls

pdf

tender8581.pdf

pdf

Tendernotice_1 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders