Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #56275959

Tender For Special Repair To Roofs And Associated Work At Otm & Md Accn At Af Station Halwara Under Ge (Af) Halwara

Issued by Statutory Bodies & Commissions/Committees · Ludhiana, Punjab
Tender Value
92.95 Lakhs
Estimated cost
Bid Submission
28 Jul 2026
19 days left
EMD
1.64 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ludhiana → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair To Roofs And Associated Work At Otm & Md Accn At Af Station Halwara Under Ge (Af) Halwara

BOQ

Name of Work:- SPECIAL REPAIR TO ROOFS AND ASSOCIATED WORK AT OTM & MD ACCN AT AF STATION HALWARA UNDER GE (AF) HALWARA
Sl. No. Item Description
1Dismantling of brick tiles or terracing tiles single layer on roofs complete all as specified and directed by Engr-in-Charge.
2Demolition of mud (mudphuska) in roofs any thickness including plastering and leeping ( whether full thickness removed or only a part thereof) complete all as specified and directed by Engr-in-Charge.
3Removal of existing roof treatment including APP membrane over roofs including removing the debris outside the MOD land complete all as specified and directed by Engr-in-Charge.
4Demolition of cement concrete (unreinforced) in roofs other than ground floor land removal from site complete all as specified and directed by Engr-in-Charge.
5Removing building materials (debris)outside the MOD land to a distance of not exceeding 100 m from the starting point loading,unloading and stacking at the site outside MoD land complete all as specified and directed by Engr-in-Charge.
6Material and labour for providing 50mm thick average cement concrete type B-1 (1:2:4) using 20mm graded aggregate as in padding to be provided in slope etc complete all as specified and directed by Engineer-in-charge
7Material and labour for providing PCC (1:2:4) type B-1 using 20mm graded aggregate as in roof kerbs or mud stops, rounded or chamfered on edges etc complete all as specified and directed by Engr-in-Charge.
8Material and labour for repairing stagnant water areas, Identify and mark areas on the Mudphuska terrace roof surface where water stagnates due to unevenness. Providing and applying a maximum of 15mm thick polymer-modified mortar (PMM) mix in a 1:5:15 ratio to the marked areas. Mix the mortar with water gradually until a smooth, workable paste is formed. Level the repaired surface. Allow the repaired surface to moisture and air cure for 7-10 days complete all as specified and directed by Engg-in-charge
9Material and labour for Roughening and cleaning the junction of wall and floor with wire brush and air blower to remove the dust particles. Moisten the surface with water & apply a bond coat of Dr. Fixit Pidicrete URP and cement (1:1) by volume with brush. Providing & Laying angle fillet (gola) of size 75 x 75 mm in width over the bond coat when it is in wet condition complete all as specified and directed by Engg-in-charge
10Material and labour for repair all visible hairline cracks on concrete roof screed more than 0.50 mm and not giving hollow sound, should be cut and widen in V shape with mechanical cutter in the size of 10 mm wide and 6 mm deep and filling the cracks with PU sealant / PMM (using SBR pidicrete URP 301)with suitable gun and smoothed with a putty knife or trowel and allow sealant tocure a minimum of 72 Hrs complete all as specified and directed by Engg-in-charge
11Material and labour for plastering 10 mm thick in CM 1:4 mixed with WPC over cleaned concrete surfaces complete all as specified and directed by Engr-in-Charge.Note : WPC will be measured and paid separately under respective item.
12Supply only integral water proofing liquid complete all as specified and directed by Engr-in-charge
13Material and labour for preparation of roof top surfaces providing and applying single component elastic cold applied polyurethene modified acrylic roofing sytem, co-elastic technology (CET) based on modified polyurethene and fully fibre reinforced, having Sun Reflectivity Index (SR) of 106 on top of concrete roof surfaces. All cracks upto 3mm at corner joints, channel and parapets should be treated with crack seal. Applying three coats including one coat of primer of Shali Urethne BTD/ Sikalastic 560/smart care damp proof ultra having coverage @ min 0.75kg/m2 and dilution upto 10% and laying reinforced fibre net and applying two coats of shaliurethne BTD/Sikalastic 560/smart care damp proof ultra @ total consumption 2kg/m2 in two for maintaining minimum dry film thickness 1.50mm and elongation at break of free film of approx 350%. The material shall be applied with brush or roller complete all as specified and directed by Engr-in-chargeNote:- The item would be executed through authorised applicator of the company to be approved by GE
14Taking down cement plaster on brick or stone walls etc, including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed by Engr-in-charge
15Demolition of Brickwork or stone boulders masonary, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc,and rubbish materials removing from site complete all as specified and directed by Engr-in-charge
16Material and labour for Brick work with sub class ‘B’ brick, straight or curved as plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed by Engr-in-charge
17Material and labour 15mm thick rendering in CM 1:4 on fair faces of brick work or concrete finishing the surface even and smooth without using extra cement complete all as specified and directed by Engr-in-charge
18Material and labour rendering 5 mm thick on fair faces of ceiling in cement mortar 1:3 finished surfaces even and smooth without using extra cement complete all as specified and directed by Engr-in-charge
19Material and labour for 10 mm thick cement mortar 1:6 on Brick or concrete surface finished even and smooth without using extra cement complete all as specified and directed by Engr-in-charge.
20Material and labour for Prepration of new plastered surfaces of walls and applying two coat of cement base paint over a coat of alkali resistant priming paint including dark blue colour of pillar/RCC/brick facia complete all as specified and directed by Engr-in-charge.
21Material and labour prepration of new surfaces of and applying three coat of white wash on ceiling complete all as specified and directed by Engr-in-charge.
22Material and labour for Prepration of new plastered surfaces of walls and applying two coat of distemper oil emulsion over a coat of primer over 2 mm thick plaster of paris putty, on new surfaces complete all as specified and directed by Engr-in-charge.
23Material and labour PCC (1:2:4) type B-1 using 20mm graded stone agregete as in bed, copings, bed plates, kerbs, water troughs and the like including weathering slightly rounded or chamferred angles and throating and use of necessary formwork where required complete all as specified and directed by Engr-in-charge.
24Material and labour for disconnecting existing water tanks setting aside (or lowering if required) for repairs, cleaning, etc and hoisting if required reconnecting and refixing in position of capacity exc 250 & nexc 500 litres complete all as specified and directed by Engr-in-charge.
25Supply and fixing in repair 500 litres rotational moulded polyethelene water storage tank (cylindrical vertical with closed top) including 20mm ball valve and hoisted and fixed in position complete all as specified and directed by Engr-in-charge.
26Supply and fixing in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints, step clamps, including all fittings (Any type of \\"T\\"/tee, bend, Y, Branch piece single/double, couplers, horse shoe bend,reducers, vent coil, access door, junction single/double, equal/unequal, any type of trap etc), 110mm dia, fixed to walls/floor/trenches etc and height of buildings upto 12 meter complete all as specified and directed by Engr-in-charge.
27Taking up or down 20 mm dia steel tubing and connections including cleaning for re-fixing or removal to store complete all as specified and directed by Engr-in-charge.
28Supply and fixing of CPVC pipes outer dia 20mm SDC 11 & plain CPVC SDR 11 fittings in trenches, fixed to walls, floors, and ceilings including cutting and chases complete all as specified and directed by Engr-in-charge.
29Supply and fixing in repair 20mm bore stop valve(gate valve), cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed by Engr-in-charge.
30Taking down and re-fixing of solar water heater system complete of any capacity from the roof top of the building carefully in serviceable condition and re-fixing complete system after roof treatment work Repairing of any leakage and replacement of wear & tear parts and redoing of installation and making it completely serviceable complete all as specified and directed by Engr-in-charge.Note:- 1. The rates quoted by the contractor shall deemed to be included for supply and fixing spare parts and items damaged during taking down and re-fixing of solar water heating system as per existing item on ground and nothing extra shall be paid to contractor on account of this.2. The unit rates quoted by the contractor is also deemed to be included for making good the disturbed surface as per existing surface without any extra cost.
31Taking down MCB DB TPN/SPN/ of any make and type inclduing dismantling all electrical connections from MCBs/MCCB/isolators and making good the distrubed surface complete all as specified and directed by Engr-in-charge.
32Disconnecting and taking down old existing sub main wiring of any description in any position complete all as specified and directed by Engr-in-charge.
33Supply and fixing Sheet metal enclosure DB SPN, 2 way with 200 Amp rated bus bar, 240 V, single door . for fixing MCB’s, isolators etc., having IP-43 protection, flush mounting, complete all as specified and directed by Engr-in-charge.
34Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) TPN 40 Amps to 63 Amps and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed by Engr-in-charge.
35Supply and fixing in repair miniature circuit breaker (MCB) SPN 6 to 32 amp 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engr-in-charge.
36Supply and fixing submain wiring with 2 X 6 sqmm (nominal area) PVC insulated FRLSH, unsheathed, multistrand, 1100 volts grade copper conductor cable single core. drawn through in and including non metalic PVC concealed conduit not less than 20mm dia medium grade and its accessories including one run of 6 sqmm PVC insulated copper conductor as earth wire complete all as specified and directed by Engr-in-charge. Note:- (i) Surface conduit shall be laid in celing portion only (ii) 2 run of main wire and one run of earth wire shall be measured as unit length.
37Material and labour Cement concrete in foundations, filling and mass concrete PCC 1:3:6 type C-2, using 40 mm graded stone aggregate complete all as specified and directed by Engr-in-charge.
38Supply and fixing Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work complete all as specified and directed by Engr-in-charge.
39Taking out of old unserviceable GI steel tubing and its connetion and fittings including complete pipe line work of size 15/25 mm bore complete all as specified and directed by Engr-in-charge.
40Supply, fixing and laying galvanised iron pipe of size 25 mm dia bore meidum class ISI marked including all necessary fittings and laying through in trenches/on wall/under hardstanding path / road etc complete all as specified and directed by Engr-in-charge.
41Supply, fixing and laying galvanised iron pipe of size 15 mm dia bore meidum class ISI marked including all necessary fittings and laying through in trenches/on wall/under hardstanding path / road etc complete all as specified and directed by Engr-in-charge.

AI Tender Summary

OUR REF NO 56275959
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 92.95 Lakhs
LAST DATE 28-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair To Roofs And Associated Work At Otm & Md Accn At Af Station Halwara Under Ge (Af) Halwara
Basic Detail
Tender No CWE(BHI)/HAL-44/2026-27
Bidding Type Tender
Location
City Ludhiana
State Punjab
Key Dates
Publish Date 02 Jul 2026
Submission Date 28 Jul 2026
Open Date 30 Jul 2026
Finance
Tender Value 92.95 Lakhs
Tender Fee 1000
EMD 1.64 Lakhs
Exemption Available
Document List
17c8f473-1a6c-4d7c-9071-fa6d4a8e0e44.html
BOQ_869054.xls
TENDER44.pdf
Tendernotice_1 (1).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 02, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Jul 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

17c8f473-1a6c-4d7c-9071-fa6d4a8e0e44.html

xls

BOQ_869054.xls

pdf

TENDER44.pdf

pdf

Tendernotice_1 (1).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders