| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CWE KARANJA NAME OF WORK: REPAIRS/REPLACEMENT TO STEPS, RAILINGS, ROOF SHEETS AND REPAIR/REPLACEMENT OF STREET LIGHT, ELECTRIC POLES, DUCT COVERS, LT CABLE AND MISC ITEMS AT EXPLOSIVE JETTY AND PIM JETTY UNDER AGE B/R-II AT NAVAL STATION KARANJA CONTRACT AGREEMENT: CWE KJ(K)- OF 2026 - 2027 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item of Work Item Code / Make Quantity Unit Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT (in Words) |
| 2 | Note :- These item are to be execured in galleries of jetty (Restricted Work Environment arrise during High tide ). The Rate quaoted shall be accordingly considered for deemed to be include scaffolding , mobilization equipment and other safety equipment as work will be carried out in sea area along the Jetty. Nothing will be paid extra on account of Working in difficult area . |
| 3 | Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specifedand directed |
| 4 | Dismantling posts or struts (Wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground (posts embedded in in concrete, brick work, masonry work, etc. ) |
| 5 | Dismantling fencing wire mesh any type complete all as specified and as directed |
| 6 | Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 7 | Supply and Fix steel work as in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS 1161 1979 grade St 240 complete all specified and directed. |
| 8 | Supply and Fix for rolled sections of FE 410W (Gde-E-250)as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats , Steel Door frame and shutter or other connecting plates complete all specified and directed. |
| 9 | Supply & fixing of framed work such as grills, gratings, cooler stands etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde E-165 incl necessary fixing to walls as directed. |
| 10 | Supply and Fix MS plate Fe 410-W (Gde E-250 quality A) (Plane/Chequered) 5 mm and over as open drain covers with 02 Nos of 150mm handle in each plate etc complete all as specified and directed by Engr-in-Charge. |
| 11 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface hard or dence soil complete all as specified and directed |
| 12 | Supply and Fix posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire mesh, etc.; flat iron fillets( for securing wire mesh etc.) including all necessary drilling, bolting or riviting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed |
| 13 | Supply and Fix mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square but, length of boltexc 5cm but n exc 10cmlong.(Diameter of neck in 11 to 15 mm) complete all as specified and directed |
| 14 | Supply and Fix Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismanlting of old Sheet as specified etc complete all as specified and directed. |
| 15 | Supply and Fix Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified etc complete all as specified and directed. |
| 16 | Material and Labour Preparation of new previously untreated steel and iron surfaces of any description not other wise described over 10 centimetre width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome complete all as specified and as directed. |
| 17 | Supply and Fix of mild steel security chain link fencing 60mmx60mm with PVC coated mesh made out of 3.0 mm dia MS wire and 1.00mm thick PVC Complete all as specfied and directed. |
| 18 | Taking down and refixing of chain link fencing in same position after replacing of damage of fencing post complete all as specified and directed by Engineer–in-Charge |
| 19 | Taking down existing angle iron from wall embadded in PCC and refixing in the same opening/position complete all as specified and as directed by Engr-in-Charge. |
| 20 | Material and labour for cement concrete C-2 1:3:6 using 40mm graded crushed stone aggregate stone aggregate as in foundation, filling and mass concrete, in fencing pole all as specified and directed. |
| 21 | Material and labour for cement concrete type D-2 1:4:8 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete etc as specified and directed. |
| 22 | Material and Labour for chequered cement concrete tile 30cmX30cmX 20 to 25mm thick set jointed and pointed in neat cement siurry in floor with grey cement and pig ments over 20mm thick screed bed or bedding layer of CM (1:4) including dismentling of old tiles complete all as specified and as directed. |
| 23 | Material and Labour for Granite (of any type) 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete including grinding and polishing incldung 20 mm thick Cement motar 1:4 including dismentling of oldstone slab / tiles complete all as specified and directed |
| 24 | Material and Labour for 20mm thick Granite (of any type) machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete including over 10mm thick recuing in cement mortar (1:3) and pointed in coloured cement to match for work on vertical surface etc including dismentlling of old tile all as specified and as directed by Engr-in-Charge |
| 25 | Material and labour for 75 mm thick cement concrete type C-1 1:3:6 using 20mm graded crushed stone aggregate as in plinth protection finished fair even laid in bays n.exc 2m in length and joints filled with bitumen mastic 1:3 complete all as specified and directed |
| 26 | Material and labour for 100mm thick cement concrete type B-2 1:2:4 using 40mm graded crushed stone aggregate as in path/floor finished fair even and smooth without using extra cement, laid in alternate panels of size not exc 4 sqm each including bitumen filling in joints complete all as specified and as directed by Engr-in-Charge. |
| 27 | Material and Labour for PCC (1:2:4) type B0 (using 12.5mm graded aggregate) in coping bed black etc including nessesary form work complete all as specified and directed. |
| 28 | Supply and Fix Steel rolling shutters, with out ball bearing, thickness of laths 1.00mm as specified including top cover, anchoring rod, hasp and staple and erected in position as indicated,complete: push pull or manual type including taking down of old Shutter complete all as specified and directed by Engr-in-Charge |
| 29 | Material and Labour for preparing new or previously untreated steel surface of any decription over 10cm in width or girth and applying 2 coats of aluminium paint over one coat of red oxide primer complete all as specified and directed. |
| 30 | Material and Labour for preparing old painted steel surface of any decription over 10cm in width or girth and applying one coats of aluminium paint complete all as specified and directed |
| 31 | Taking down existing bitumen felt roof treatment including cement mortar bedding and cleaning the surface and removal outside the MoD land, complete all as specified and as directed by Engr-in-Charge. Note :- 1. Taking down earthing strips incl insulators from roof for treatment and re-fixing of same with existing specification in the same position after laid APP membrane including replacement of broken insulators, PVC rawl plus & screws etc. are deemed to be inclusive of rate quoted by the contractor.2. Unit rate quoted shall also include for removal of PVC water storage tank wherever existing carefully and refixing at the same or other position after completion of roof repair work3. APP work shall be carried out on RCC PENT roof at 20 -30 mtr height (non accessible roof). |
| 32 | Material and Labour for brushing neat cement slurry with 3.00 Kg of cement per Sqm complete all as specifed and directed |
| 33 | Material and Labour for cement concrete M15 (Nominal Mix) using 12.5 mm nominal size graded crushed stone aggregate mixed with water proofing compound as levelling course of roof padding finished even and fair complete all as specified and as directed. Note:- Water proofing compound shall be measured and paid for separately. |
| 34 | Material and Labour for rendering 10mm thick in cement mortar 1:4 on roof top surface including WPC as per manufacturer instructions complete all as specified and as directed.Note : WPC will be measured separately |
| 35 | Material and Labour for cleaning the new surfaces concrete with wire brushing and applying water proofing treatment as under:-(i) Apply oil bound bitumen primer @ 0.40 Litre/Sqm manufactured by the same agency as that of APP with density of 0.87 to 0.89 Kg/Litre at 25 degree cesius on the pepared dry roof surface. (ii) Laying torch applied APP polymer modified membrane 4mm thick with non-wooven ployster mat as reinforcement weighing n.less than 3.50 Kg/Sqm with white gravel/mineral finished by thermo fusion process all as decribed under particular specification (iii) Applying two coats of bitumen water proofing aluminium heat resistance paint on the roof as per manufacture instructions complete Notes :- Rates are include for Item No (i) to (iii) Note:- (a) The Work shall be executed through authorised applicator of Manufacture . (b) The primer should be of the same manufacture as APP Membrane. |
| 36 | Supplying only Liquid water proofing compound complete all as specifed and directed by Engr-in-charge |
| 37 | Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc. |
| 38 | Demolition of stone/brick masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlar facings dressed stone work and pre cast concrete articles complete all as specified and directed. |
| 39 | -ditto all as per srl item No. 36 above but pre-cast concrete block walling complete all as specified and directed. |
| 40 | Material and Labour for pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width in type C1 (1:3:6) 20 mm graged stone aggregate and setting in mortar (1:6) complete all as specified and as directed |
| 41 | All as per srl item No. 38 here in before but except PCC Block WorksNote:- Serviceable Blocks obatined from srl item No. 37 shall be re-used in srl item No. 39 after cleaning etc complete all as specified and directed by Engr-in-Charge. |
| 42 | Material and Labour brickwork with sub class 'B' bricks , straight or curved on plan exc 6m mean raidus built in cement mortar 1:6 complete all as specified and directed |
| 43 | All as per srl item No. 40 here in before but except bricks Note:- Serviceable bricks obatined from srl item No. 36 shall be re-used in srl item No. 41 after cleaning etc complete all as specified and directed by Engr-in-Charge. |
| 44 | Material and Labour for walling of random rubble, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar 1:6 all as specified and directed. |
| 45 | -Ditto- all as per item No. 42 hereinbefore but except stone. Note:- stone obtained from item No 36 shall be reused. |
| 46 | Material and Labour for rendering 15 mm thick in CM 1:4 on fair faces of brick/concrete surfaces with two coats i.e (10 mm thick backing coat and 5mm thick finishing coat) , finished even and smooth complete all as specified and directed. (Note:- Item rate shall be include any height of Bldgs for scafolding as all arrangement.) |
| 47 | Material and Labour for rendering 10 mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth complete all as specified. (Note:- Item rate shall be include any height of Bldgs for scafolding as all arrangement.) |
| 48 | Material and Labour applying minimum 1mm thick wall care Putty of Birl wall care putty or equivalent on wall /ceiling surfaces for filling &making undulation surface even and smooth complete all as specified and as directed |
| 49 | Material and labour for preparation of new plastered surfaces of walls/ ceiling and applying two coat of oil distemper over one coat of alkaliresistant primer and 2 mm thick wall care putty, complete all as specified and as directed. Note:- 1. Putty will be paid under relevant item where applied. |
| 50 | Complete removal of existing treatment from old decorated plastered surfaces of walls and ceiling by , removal of nails etc & filling cracks/hole with putty, applying wall care putty upto 2 mm thick (multipurpose mixer shall be used for uniform and proper mixing of putty) and applying two coats oil emulsion distemper white or coloured over a coat of approved primer by auto roller complete all as specified & directed Note:- Putty will be paid under relevant item where applied |
| 51 | Complete removal of existing treatment of walls and Material and Labour for applying two coats of acrylic (antifungal) exterior grade paint of camouflage/Plian pattern over one coat of primer on wall/roof by auto roller complete all as specified and directed. |
| 52 | Material and Labour for preparation of new or previously untreated plastered surfaces of walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces two coats of acrylic antifungal paint exterior grade paint on one coat of primer complete all as specified and as directed. |
| 53 | Material and Labour for preparation of new or previously untreated plastered surfaces of walls/Ceiling and applying two coats of acrylic antifungal paint exterior grade paint CAMOUFLAGE PATTERN on one coat of primer complete all as specified and as directed. |
| 54 | Material and Labour for taking down defective street light/flood light fittings of any size/type/capacity from any height of LT pole/wall/high mast of any location exceeding 7.0 metre height for repair work and refixing in same position after repair work including checking, inspecting, testing and commissioning complete all as directed by Engr-in-Charge.Notes :- (i) Electronic driver, surge protection device etc shall be measured and paid separately under relevant item of BoQ.(ii) Necessary tools like ladders and other T&P required etc shall be arranged by the contractor and cost of the same including minor spares like nuts, bolts, washers etc. |
| 55 | Supply, fixing, connecting and testing in replacement integral LED flood light fitting, 120 watts energy saving & environmental friendly long life versatile pressure die cast aluminium body with clear toughened glass, individual LEDs with secondary lens optics with IP-66 ingress protection, over voltage protection, short circuit protection, open circuit protection, surge protection, LED CCT is 5700 K as light source suitable making connection with three core PVC insulated and sheathed copper conductor cable of size 1.5/2.5 Sqmm, complete all as specified and directed by Engr-in-Charge. |
| 56 | Supply, fixing, connecting and testing in replacement integral LED flood light fitting, 200 watts energy saving & environmental friendly long life versatile pressure die cast aluminium body with clear toughened glass , individual LEDs with secondary lens optics with IP66 ingress protection ,over voltage protection, short circuit protection ,open circuit protection ,external surge protection, LED CCT is 5700 K as light source suitable making connection with three core PVC insulated and sheathed copper conductor cable of size 1.5/2.5 Sqmm complete all as specified and directed by Engr-in-Charge. |
| 57 | Supply, fixing, connecting and testing in replacement integral LED Street light fitting, 60 watts energy saving & environmental friendly long life versatile pressure die cast aluminium body with clear toughened glass with over voltage protection, short circuit protection ,open circuit protection ,surge protection, LED CCT is 5700 K and IP-66 as light source suitable making connection with three core PVC insulated and sheathed copper conductor cable of size 1.5/2.5 Sqmm, complete all as specified and directed by Engr-in-Charge. |
| 58 | Supply, fixing, connecting and testing in replacement integral LED Street light fitting, 90 watts energy saving & environmental friendly long life versatile pressure die cast aluminium body with clear toughened glass , individual LEDs with secondary lens optics with IP66 ingress protection, over voltage protection, short circuit protection, open circuit protection, surge protection, LED CCT is 5700 K as light source suitable making connection with three core PVC insulated and sheathed copper conductor cable of size 1.5/2.5 Sqmm, complete all as specified and directed by Engr-in-Charge. |
| 59 | Supply, fixing, connecting and testing in replacement integral LED Street light fitting, 120 watts energy saving & environmental friendly long life versatile pressure die cast aluminium body with clear toughened glass, individual LEDs with secondary lens optics with IP66 ingress protection , over voltage protection, short circuit protection ,open circuit protection ,external surge protection ,LED CCT is 5700 K as light source suitable making connection with three core PVC insulated and sheathed copper conductor cable of size 1.5/2.5 Sqmm, complete all as specified and directed by Engr-in-Charge. |
| 60 | Material and Labour for preparation of old painted surfaces of steel tubular pole/strut, of any description and in any position of any height and scrapping of pole with emery paper and applying two coat of aluminium paint on all the metallic surfaces including protection pipe, clamps, GI pipe bracket of street/security light, and pasting reflector tape, self adhesive, water proof in 3 different colour as directed for around the pole with applying one coat of white wash painting on coping of pole and numbering of poles, complete all as specified and directed by Engr-in-Charge. |
| 61 | Supply and fixing 1.5 Sqmm FRLSH PVC insulated three core unsheathed industrial multistrand cable with flame retardant low smoke (FRLSH) properties with flexible bright annealed bare copper conductor for voltage grade upto 1100 V confirming to IS-694:2010, complete all as specified and directed by Engr-in-Charge. |
| 62 | Supply and fixing 2.5 Sqmm FRLSH PVC insulated three core unsheathed industrial multistrand cable with flame retardant low smoke (FRLSH) properties with flexible bright annealed bare copper conductor for voltage grade upto 1100 V confirming to IS-694:2010, complete all as specified and directed by Engr-in-Charge. |
| 63 | Supply & Fixing, Laying, jointing, connecting & testing XLPE/PVC insulated PVC sheathed cable heavy duty 1100 volts grade, aluminium conductor in trenches / pipe ducts/drawn through DWC pipe of following sizes including taking out old unserviceable cable, complete all as specified and directed by Engr-in-Charge :-(a) 4 core 16 Sqmm |
| 64 | (b) 3.5 core 50 Sqmm |
| 65 | Material and Labour for taking down existing rusted pole with all accessories from existing position and set a side for further disposal and Supply and erection of steel tubular pole high mast pole of shape as per OEM or as directed of 12 metre length in 02 segment, 3.3 mm thickness, top and bottom having internal dia 150/360 mm, base plate size 550x18 mm, suitable for J drum winch, provision for mounting 06/09 Nos LED flood lights or as directed complete including 2 coats of aluminium paint over one coat of red oxide zinc chrome primer on external exposed surfaces and 2 coats of black bituminous paint on portion embedded in concrete in internal surfaces of pole, complete all as specified and directed by Engr-in-Charge. |
| 66 | Material and Labour for SP of 6-32 A ,240 V with breaking capacity 10 KA Conforming to IS/IEC 60898-1:2015 , complete all as specified and directed by Engr-in-Charge. |
| 67 | Supply and fix in repair Driver for 120-150 Watts LED lights as per existing make for the following capacity including taking down unserviceable drive, complete all as specified and directed by Engr-in-Charge. |
| 68 | Material and Labour for Earthing complete with GI earth plate electrode 60cm x 60 cm x 6 mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level connected to and including GI strip 32 x 6 mm by means of bolts, nuts and check nuts and washers etc made of GI & connected to Earthing test point and earth dolly all as shown in elect plate No 3 of SSR Pt-I including all necessary earth work, excavation, PCC chamber, chamber cover with handle (PCC 1:2:4) including 40 mm dia protection pipe & 20 mm dia watering pipe and wire mesh funnel etc, complete all as specified and directed by Engr-in-Charge. |
| 69 | Supply, installing, testing and commissioning in replacement of factory made Outdoor type LT cubical panel board suitable for operation on 415 volts, 3 phase, 4 wire 50 Hz supply system including bus bar chamber in centre ( vertically) and cable alley either side, outer shell shall be made out of 3.0 mm thick CRCA sheet duly powder coated siemens grey shade and completely weather, vermin & dust proof, adequate air ventilation at sides & back, outer door shall be provided with double door fix with hinges and locking arrangements etc suitable to accommodate the following mentioned fittings and inner shell shall be made out of 2mm thick CRCA sheet duly powder coated & compartmentalized for each control gear including front openable single door with half nob type locking, including provision for taking out incoming and outgoing cables duly marked with riveted letter plated of appropriate size for each feeder / block cable, danger board, detachable plate at bottom for cable entry etc including double compression type cable gland with bottom frame made out of angle iron 40mm x 40mm x 4 mm and 450mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over and including 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body with and including following accessories, complete all as specified and directed by Engr-in-Charge. :- |
| 70 | INCOMING(a) MCCB 4P, 315 Amp, 415V, AC, 25 KA - 01 (Incomer)(b) Digital volt meter 0-500 Volts with selector switch digital type-01 No(c) Digital Ampere meter 0-400 amps range with selector switch and including CTsOUTGOING: MCCBs(a) MCCB 415 Volts,125 Amp rating,16 KA, 4 Pole - 04 No (b) MCCB ,63 Amp , rating 4 Pole , 16 KA, 415 Volts -04 Nos(c) MCB TP, 63Amp , rating 2 Pole - 04 Nos(c) MCB DP, 32Amp , rating 2 Pole - 04 Nos(d) Internal all links & control cable and indicators - set of threeOutgoing : Socket outlets(a) Industrial panel mounted socket outlet made of polyamide material as per IEC 603091&2, ISO 14001&9001 certified, 200/250V, 16 Amps 2P+E - 02 Nos(b) Industrial panel mounted socket outlet made of polyamide material as per IEC 603091&2, ISO 14001&9001 certified, 200/250V, 32 Amps 2P+E - 02 Nos(c) Industrial panel mounted socket outlet made of polyamide material as per IEC 603091&2, ISO 14001&9001 certified, 380/415V, 16 Amps 3P+E - 02 Nos(c) Industrial panel mounted socket outlet made of polyamide material as per IEC 603091&2, ISO 14001&9001 certified, 380/415V, 32 Amps 3P+E - 02 Nos |
| 71 | Supply and Fix in replacement LED Tiranga rope light 18 metre length, IP-65, input power 10W/metre, input voltage 220-240V AC, 50 Hz, PF 0.95, 120 LED/metre, having 6 metre length orange, white, green each, suitable for (-) 20 degree Celsius to (+)45 degree Celsius etc including driver for each cut piece, complete all as specified and directed by Engr-in-Charge. |
| 72 | Supply and erection of steel tubular swaged pole 410 SP 22, 8.5 metre long ,complete with cast iron base plate, finial Taper plug, bolts, nuts, and screws as specified type conforming to IS 2713 complete including 2 coats of aluminium paint over one coat of red oxide zinc chrome primer on external exposed surfaces and 2 coats of black bituminous paint on portion embedded in concrete in internal surfaces of pole including taking out old pole, complete all as specified and directed by Engr-in-Charge. |
| 73 | Material and Labour for in replacement of floor mounted manual revolving LED search light of capacity 400 watt, 220V, AC complete with all accessories prewired, complete all as specified and directed by Engr-in-Charge. |
| 74 | Excavation in trenches not exc 1.5 metre wide and not exc 1.5 metre depth and getting out in soft/loose soil, complete all as specified and directed by Engr-in-Charge. |
| 75 | Returning, filling in, including spreading, levelling watering and well ramming in layers not exc 25cm, complete all as specified and directed by Engr-in-Charge. |
| 76 | Removing excavated materials to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the Starting point, complete all as specified and directed by Engr-in-Charge. |
| 77 | Material and Labour in repair for precast reinforced cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) set in cement mortar (1:6) work for landings, cover slabs, manholes, chajjas, water troughs, manger shleves and similar articles with plain faces of size 600MMX600MMX50MM with 2mm thick GI sheet around the slabs with provision of two nos of picking up points complete all as specified and as directed by Engr-in-charge. |
| 78 | Material and Labour for replacement of wired 4-Zone Matrix Amplifier, Wall Speaker Package Up To 24 Speakers Background Music System complete with all accessories including speakers,wire of required length, amplifier etc and required protective conduit for speaker wiring for 24 poles alternatively on jetty, all-weather durability certified to withstand extreme UV, salt, and moisture, broad 180-degree sound coverage, and the innovative Speed-Lock mounting system for effortless installation on street lights poles including taking down old unserviceable. |
| 79 | Supply, fixing, connecting and testing of integral LED 75 W Tricolour bollard light,system wattage 75 W colour output -saffron,white & green through polycarbonate diffuser,polybody-1 M with epoxy primer & UV stablised PU paint complete including PCC foundation all as specified and directed . |
| 80 | Supply, fixing, connecting and testing of integral aluminium and steel construction circular/polygonal fancy/decorative pole light with LED lamp complete including foundation work as required or directed. Light Type LED, Pole Height 3 m, Power Rating 40/60 W, Outdoor type, Lighting Color Warm White, Input Voltage 220 V, Frequency 50/60HZ complete all as specified and directed |
| 81 | Demolition and dismantling existing damaged/cracked PCC foundation of street light poles and including taking down and dismantling of pole and set a side for carrying out necessary repair work on damaged/cracked portion if required or complete where directed including removing loose foundation bolts if any and refixing in same position complete and erecting the pole in the same position with all necessary connections etc, complete all as specified and directed by Engr-in-Charge. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 22 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 24 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender