Defence Statutory Bodies & Commissions/Committees Closing in 6 days TDR #56275933

Tender For Certain Repair/Maint Of All Type Acs, Dg Sets, Amf Panels, Security /Flood Lights, Ug Pipe Line Including Cleaning/Maint Of Oht Reservoir, Ug Sump, Rising Main Etc And Other E/M Works At Af Stn Aastha Complex & 5 Aflu Under Aor Of Ge(Af) F

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
45 Lakhs
Estimated cost
Bid Submission
16 Jul 2026
6 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Certain Repair/Maint Of All Type Acs, Dg Sets, Amf Panels, Security /Flood Lights, Ug Pipe Line Including Cleaning/Maint Of Oht Reservoir, Ug Sump, Rising Main Etc And Other E/M Works At Af Stn Aastha Complex & 5 Aflu Under Aor Of Ge(Af) Faridabad

BOQ

Name of Work:- CERTAIN REPAIR/MAINT OF ALL TYPE ACS, DG SETS, AMF PANELS, SECURITY /FLOOD LIGHTS, UG PIPE LINE INCLUDING CLEANING/MAINT OF OHT RESERVOIR, UG SUMP, RISING MAIN ETC AND OTHER E/M WORKS AT AF STN AASTHA COMPLEX & 5 AFLU UNDER AOR OF GE(AF) FARIDABAD
Sl. No. Item Description
1Material and Labour for servicing of split type AC's of capacity 1.5/2 TR comprising of the following tasks installed at different locations including testing complete all as specified and directed.(a) Inspecting and checking the Indoor/outdoor units for noise free operation.(b) Checking the electrical connection for tightness(c) Cleaning the condenser with cleaning agent followed with pressurized water and cleaning the cooling coil with air blower with water pressure gun.(d) Greasing/Oiling of condenser fan motor and blower motor.(e) Checking for any refrigerant leakage by pressure testing and repair it.(f) Checking for serviceability of remote control unit and replace with new battery.
2Repair & maintenance of Refrigerator / Water Cooler /deep freezer any capacity comprising of the following tasks at different location complete all as specified and directed.(a) Inspecting, taking down, brushing cleaning with blower including acid/detergent wash of condenser and cooling coil.(b) Carry out operation of blower and compressor and ensure that satisfactory functioning of all parts.(c) Inspecting the leakage in the system.(d) Checking of the earth continuity of electrical parts.(e) Checking the functioning of thermostat.(f) Inspection of all electrical parts.(g) Testing the machine for satisfactory operation.(h) Check and correct all electrical wiring & test its functioning(j) Testing of Refrigerator after repair.
3Material and Labour for repair to leaking area of split type AC unit of capacity 1.5/2 TR capacity including nitrozen pressure testing, dehydration and any type of gas charging complete all as specified and directed.
4Material and Labour for repair to leaking area of window type AC unit of capacity 1.5 capacity including pressure testing, dehydration and any type of gas charging complete all as specified and directed.
5Supply and charging Refrigerant(R410,R32,R134 and existing refrigerent) to any type of AC unit including CFC free and non CFC Free AC complete all as specified and directed.
6Supply and fixing in replacement of starting relay 25 Amps for split type AC units of capacity 2 /1.5TR as required at site complete all as specified and directed.
7Supply and fixing in replacement of start run capacitor 45/60 MFD for split type A/C's of capacity 1.5/2 TR complete all as specified and directed.
8Supply & fixing in replacement of running capacitor 6 mfd for blower motor as required at site complete all as specified and directed.
9Taking out and replacement of condenser fan motor DC of split type AC 1.5/2 ton units of capacity 1.5/ 2 TR complete all as specified and directed.
10Taking out and replacement of condenser fan motor AC of split type AC units of capacity 1.5/ 2 TR complete all as specified and directed.
11Material & Labour for Fixing the new blower motor DC in replacement of for split type A/C unit as per existing model complete all as specified and directed.
12Supply & Fixing the new blower motor AC for split type A/C unit as per existing model complete all as specified and directed.
13S&F in replacement the new swing motor as per existing model/make for split type AC 1.5/2TR unit complete all as specified and directed.
14Supply and fix out door fan blade in existing model complete all as specified and directed.
15Material and Labour for replacement of defective electronic components / IC Circuits of PCB card with display unit suitable of 1.5/2 ton split AC indoor unit as required on site including replacement of defective electronic components / IC Circuits, complete all as specified and directed.
16Material and Labour for replacement PCB card suitable of 1.5/2 ton inverter split AC as required on site including sensor complete all as specified and as directed.
17Disconnecting and taking down burnt condenser coil of capacity 1.5TR from split type AC unit and Supply and Fix new copper condesor coil as per existing model including testing complete all as specified and directed.
18Materal and Labour for replacement of cooling coil assembly complete suitable for 1.5 / 2 ton indoor unit Split type AC incl testing for satisfactory working condition complete all as specified and directed.
19Materal and Labour for replacement cooling coil of window type AC 1.5 TR including after taking out old unserviceable one,soldering/welding dehydration achieve complete all as specified and directed.
20Disconnecting and taking down burnt compressor of capacity 1.5TR from split type AC unit and Supply and fix new one as per existing model complete including testing complete all as specified and directed.
21Disconnecting and taking down burnt compressor of capacity 2TR from split type AC unit and Supply and fix new one as per existing model complete including testing complete all as specified and directed.
22Labour for dismantling of Split AC 1.5/2 ton complete unit from the existing place complete all as specified and directed.
23Labour for fixing of Split AC 1.5/2 ton including masonary work complete unit complete all as directed.
24Material and labour install wall mounted stand for mounting indoor unit of split AC with all fixing arrangement complete all as specified and directed.
25Material and labour wall mounted stand for mounting outdoor unit of split AC complete with all fixing arrangement complete all as specified and directed.
26M&L in repairs copper tubing 3/8” outer dia suitable for AC 2TR capacity complete all as specified and directed.
27All as per item No 26 above but here in before but 5/8” outer dia.
28Material and Labour for providing insulation 9mm thick for dia 1/4\\",3/8\\",1/2\\",5/8\\",6/8\\" copper tubing’s from Indoor to outdoor units with foam insulation followed with clamps complete all as specified and directed.
29Material and labour for the new remote with battery as per existing model for 1.5/2 TR split type A/C unit complete all as specified and directed.
30Material and labour in replacement of wall mounted Voltage stabilizers 4/5 KVA single phase,230 Volts AC,voltage variation between 140- 300,intelligent time delay system,digital display,low and high voltage cut-off system, complete all as specified and directed.
31M & L for Taking out unserviceable indoor unit and supply and fix the new indoor unit of 1.5/2 TR capacity split AC 230 Volts single phase including installing ,charging complete all as specified and directed.
32Material and labour in replacement 3 core copper PVC insulated of size 4 Sqmm complete all as specified and directed.
33M & L for Taking out unserviceable outdoor unit and supply and fix the new OUTDOOR unit of 1.5/2 TR capacity split AC 230 Volts single phase including installing ,charging complete all as specified and directed.
34Taking down desert cooler of any size by disconnecting electrical supply, cleaning, oiling of all moving part of pump & exhaust fan/kit, Replacing PVC pipes, nozzles, distributors, pads, checking electrical connections complete all as specified and directed.
35Material and labour in replacement of wood pads(set of three)as per sample complete all as specified and directed.
36Material and labour in replacement the new desert cooler pump.including testing for proper functioning complete all as specified and directed.
37Material and labour in replacement the new exhaust fan kit with leg assembly 450mm sweep complete all as specified and directed.
38Material and labour in replacement the new exhaust fan motor with leg assembly 450mm sweep complete all as specified and directed.
39Material and labour in replacement the new exhaust fan blade 450mm sweep, complete all as specified and directed.
40Material and labour in replacement new body of desert cooler of 600 x 600 x 900 mm size or in next higher size in volume duly painted of 20 SWG sheet with 22 SWG flops, front grill, PVC pipe, nozzle,selector switches,swinging motor,distributor and nut bolts washers for fixing fan clamps, complete all as specified and directed.
41Material and labour front grill of desert cooler as per sample complete all as specified and directed.
42Material and labour for PVC flexible distributor heavy duty with nozzle as per sample complete all as specified and directed.
43M & L for replacement of unserviceable sealed compressor with new hermetic sealed compressor of existing make including charging of refrigerant gas and testing on full load complete all as specified and directed.
44M & L for replacement of unserviceable compressor with new compressor of existing make including charging of refrigerant gas and testing on full load complete all as specified and directed.
45M&L PVC insulated FRLS single core with strandard copper cable of size 4 Sqmm in two run and 4 Sqmm one run for earth and drawing through existing concealed conduit including taking down old UNSV cable complete all as specified and directed. Note :- 2 runs of 4 Sqmm cable and one run of 4 sqmm cable will be measured as one running meter for the purpose of measurement and payment.
46Material and labour in repairs,Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, complete all as specified and directed.
47Material and labour in replacement of 3 pin socket metalic plug top industrial type complete all as specified and directed.
48M&L for General Servicing of DG sets upto 100 KVA , comprising of Cleaning & greasing of the parts, Tappet setting as per standard, Fan belt, tensioner pulley and lever adjustments, Tightening of all the nuts, bolts and clamps, Testing & checking of AC & DC Wiring, Self & Charging Alternator cleaning and testing, checking of working & minor fault removal, Checking of Supply & return fuel pipes from fuel tank to engine, Cleaning of hydraulic governer , Cleaning of radiator complete set. Checking of FIP timing by Fuel cut off method including Transportation, Labour charges & minor material required for servicing etc. as reqd complete all as specified and directed.Note: Cost of unserviceable items will be measured and paid seperately under relevant items.
49Supply only the following items of DG Set of various capacity complete all as specified and directed:-
50Supply only Element lub oil filter Cartrige complete all as specified and directed.
51Supply only fuel filtter Cartage complete all as specified and directed.
52Supply only Pre Filter Assembly complete all as specified and directed.
53Supply only Air Filter for Set complete all as specified and directed.
54Supply only seal 'O' ring complete all as specified and directed.
55Supply only genuine Engine oil complete all as specified and directed.
56Supply only super plus Coolent complete all as specified and directed.
57Supply only distilled water complete all as specified and directed.
58Supply only Battery terminals , lugs , bolts complete all as specified and directed.
59Supply only Battery leads copper conductor multi wired 35 Sqmm, complete all as specified and directed.
60Supply only Hinges for DG set door of any size, any type as required on site, complete all as specified and directed.
61M&L for Dismantling the radiator and fan from the engine for cleaning of copper tubes and cooling fins by descaling solution and using air compressor ,soldering on leakage, patch work and re-assembling the radiator and fitted with DG set properly including replacement of radiator hose pipe with clamps and bolt/nut with washer, leak check and pressure testing including transporting to repair workshop and bringing back for upto 100 KVA complete all as specified and directed.
62Supply, replacment and testing of radiator assembly of DG Set upto 100 KVA complete all as specified and as directed.
63Supply and replacement of low lube oil pressure sensor upto 100 KVA DG Set complete all as specified and as directed.
64M&L for complete oherhauling of Engine incl opening of engine head upto 100 KVA DG Set carefully and Servicing of internal parts of engine, piston, lining etc and entire assembly and fixing the parts after opening complete all as specified and directed.Note :- Spare part are paid separately.
65M&L for replacement of the following unserviceable parts upto 100 KVA DG set as per the existing Kirloskar model of the DG set complete all as specified and directed:-
66Piston
67Ring set
68Piston pin
69CR Bearing
70Head valve
71Head Gas kit
72Head seal
73Packing kit of the engine
74M&L for replacement of engine lining after complete opening of engine upto 100 KVA DG Set including topup of engine oil complete all as specified and directed.
75M&L in Repair of fuel nozzeles upto 100 KVA DG Set complete all as specified and directed.
76M&L in repair of turbocharger upto 100 KVA DG Set complete all as specified and directed.
77Supply and fixing in repair of Water Pump of Radiator suitable for DG set Radiator upto 100KVA DG complete all as specified and directed.
78M&L for Removal & replacement of fly wheel gear ring suitable for upto 100 KVA DG set connection & testing complete all as specified and directed.
79M&L for Removal & replacement of thermostat suitable for upto 100 KVA DG set connection & testing complete all as specified and directed.
80Supply and fixing in repair of AVR for DG set having capacity 100 KVA complete all as specified and directed.
81Supply, fixing and testing for smoothing fuctioning Fan Belt suitable for DG set up to 100 KVA complete all as specified and directed.
82Supply and fixing in all type of hose pipe with clamps , over flow pipe, copper tube fuel supply pipe, etc with clip and complete fittings suitable for DG set upto 80 KVA complete all as specified and directed.
83S&F for fuel hose pipe from fuel filter to fuel pump for DG set upto 100 KVA complete all as specified and directed.
84S&F for fuel pipe from fuel tank to fuel filter for DG Set 100 KVA complete all as specified and directed.
85Supply and fixing mounting rubber bushing set of 6 for existing generator complete all as specified and directed.
86S&F of under/over voltage relay 3 phase 415V for DG set of capacity upto 100 KVA complete all as specified and directed.
87Supply & Fixing in repair of Battary Charger 12V DC, 5 Amp of Autocut Electrical Battery Charger Unit SMPS with Constant Voltage Output with Battery Charging Transformer and Moulded Rectifier Unit etc suitable for smoothing functioning of DG set as required on site complete all as specified and directed.
88Supply & Fixing in DC 12V Stop Solenoid Coil suitable for DG Set complete all as specified and directed.
89Supply and replacement of Battery 12 Volt 100 AH suitable DG set complete all as specified and directed.
90M&L for repairing of self starter of DG set capacity 12 Volts including transporting upto workshop to carry out necessary replacement of burnt copper winding with new copper winding/ coil of existing gauge from rotor and stator coil, cleaning of slots, dryings varnishing and proper insulating to winding complete all as specified and directed.
91M&L for carrying out complete over hauling/servicing of DG set panel /AMF panel/control panel including checking and rewiring of faulty electrical circuit using 1.5 Sqmm FRLS copper conductor for DG set of any type/make /capacity and making all electric connection and testing for smooth operation complete all as specified and directed.
92Labour only for rectification of fault in AMF panel of DG set and testing on load ranging from 80KVA to 320KVA complete all as specified and directed.
93M&L for replacement of relay of AMF panel complete all as specified and directed.
94M&L for replacement of display panel of AMF suitable for DG set rating 80 KVA along with all connections and push buttons for mode change and start stop button complete all as specified and directed.
95Supply and fixing in repair IOPS Module digital display controller unit suitable for exisitng 320KVA DG Set complete all as specified and directed
96S&F in repairs MCCB 3 pole 415 volts fixed type 160 Amps with braking capacity 25KA after taking out old U/S one complete all as specified and directed.
97S&F in repairs MCCB 3 pole 415 volts fixed type 200 Amps with braking capacity 36KA after taking out old U/S one complete all as specified and directed.
98S&F MNX 95, 3 pole contractor,2 NO+ 2 NC,415 volts AC, confirms to IS/IEC 60947 -4-1, in existing model and make including after taking out old unserviceable one, complete all as specified and directed.
99S&F Contactor, (4 Pole AC & DC Control) operational current AC1,160 Amps,poles composition- 4NO,DC control ref-LP1D80004 of TC complete all as specified and directed.
100S& F Panel LED indication lamps (R/Y/B) complete all as specified and as directed.
101S&F Rotary switch of existing make complete all as specified and as directed.
102S&F in repairs digital volt meter ,415 volts,including after taking out old unserviceable one complete all as specified and directed.
103S&F in repairs digital Ammeter,415 volts grade,100 Amps rating,including and after taking out old unserviceable one complete all as specified and directed.
104M&L for attending of any breakdown of standby power supply in any location, whenever required round the clock, rectify the fault and restore the standby supply within three hours after receipt of complaint of any nature ie engine, alternator, control panel/AMF pael etc complete all as specified and directed.Note- (i) The cost of replaced spare parts will be paid and measure seperatly. (ii) If complaint is not attended by contractor with in five hours the penalty of Rs 500/- per hour to be imposed and amount of penalty will be deducted from RAR. (iii) The cost of transportation (to and from) for all kind of necessary equipment /T&P shall be arranged/brought by contractor to complete the job at site or at E/M Yard and no extra cost shall be paid to the contractor to this effect. (iv) Complaint shall be lodged by telephonically so contractor to specify the telephone/mobile No who will receive the complaint round the clock.
105Supply and fix in replacement of Onload Changeover switch 200 Amp, 4 pole ,415 V,50 Hz in sheet metal enclosure complete all as specified and directed.
106M& L for welding each canopy door to the outer unit for proper closing and opening including hinges and repainting complete all as specified and directed.
107M&L spray gun painting of generator upto 100 KVA in existing colour with smooth finishing compete all as specified and as directed.
108M & L for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including using galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth plate surrounded by packed layer of char coal dust and common salt, 15cm thick all around bottom and top and watering pipe 20mm bore of GI light grade with funnel, wire mesh and 40 mm dia GI protection pipe medium grade all as shown in electrical plate No 3 of SSR Part-I and connected to earthing test point, main switch board and testing on completion including excavation, earth work concrete pit with 80mm thick RCC cover in RCC 1:2:4 type B-1 duly reinforced with MS bars 8mm dia @ 150C/C both ways and pit chamber in PCC 1:2:4 type B-1 with 2 Nos suitable lifting handles of 12mm MS bar complete all as specified and directed.
109S & F in repairs Earth test box made of powder coated, 3.15 mm thick, CRCA sheet,20 cm x 20 cm x 10 cm size conforming to CPRI approved and IP-65 protection class,right hinge openable type including mounting arrangement such as making hole in wall,providing MS clamp,nut,bolt etc complete manufactured through approved manufacturers, complete all as specified and directed.
110S&F in repair wall mounted TPN busbar chamber factory made with busbar of current rating 400 Amp, 415, 4 way complete all as specified and directed.
111S & F rubber insulation mat of size 1.8 mtr x0.9mtr wide 2mm thick green / blue colour ISI marked embozzed for up to 3.3 KV complete all as specified and directed.
112Excavation in trenches in soft / loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 mtr depth for laying of cables/poles or foundation etc and getting out complete all as specified and directed.
113All as per item No 112 for each additional 1.5 mtr or part their of in depth beyond the first 1.5 mtr
114Returning, filling, including spreeding leveling watering and well ramming in layers not exceeding 25 cm apart complete all as specified and directed.
115Removing of surplus excavated soil to distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed.
116Material and labor for sand cushioning to XLPE cable with using clean dry and natural river sand with a layer of 8 cm thick before laying the cable and 15 cm thick layer after laying the cable and this then gently punned down to a thick of 10 cm above the top the upper most cable complete all as specified and directed.
117Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size 250 mm x 150mm x 40mm, complete all as specified and directed.
118Supply, Laying,Connecting and testing in repairs cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volt grade cross sectional area 35 Sqmm 3.5 core complete all as specified and directed.
119All as per item No 118 above but Size 25 sqmm 4 core.
120All as item per No 118 above but Size 16 sqmm 4 core.
121All as item per No 118 above but Size 10 sqmm 2 core.
122Supply and fix in replacement post top lantern LED 40 W or next highest wattage having IP65 protction for single phase connection 50 Hz 230 Volts complete all as specified and directed.
123Supply and Fixing LED street light fitting 60 Watt pressure die case aluminium housing LED street light luminaires suitable for existing street light pole including all fixing accessaries complete all as specified and directed.
124S& fixing LED flood light luminarie 70 W with high pressure die cast housing acting as heat sink in order to ensure better performance having IP66 ingress protection complete all as specified and directed.Note : All T&P ie ladder,Tools,Safty glooves etc will be provided by the contractor without any extra cost to height upto 25 mtr
125S& fixing LED flood light luminarie 120 W with high pressure die cast housing acting as heat sink in order to ensure better performance having IP66 ingress protection complete all as specified and directed.Note : All T&P ie ladder,Tools,Safty glooves etc will be provided by the contractor without any extra cost to height upto 25 mtr
126S& fixing LED flood light luminarie 170 W with high pressure die cast housing acting as heat sink in order to ensure better performance having IP66 ingress protection complete all as specified and directed.
127Supply and fix single phase driver for LED street light / flood light of 45 to 200 watt capacity and compatible with existing street light/ flood light any type / any rating complete all as specified and directed.
128S&F in replacement street light GI pipe bracket 50 mm dia 1.50metre length (ISI marked) light grade bend to shape with two Nos MS clamp duly painted nuts and bolts etc complete all as specified and directed.
129M&L for scrapping of surface of steel tubular poles of any size with emery paper and painting of pole one coat of primer and two coats of silver colour paint including writing pole No on yellow colour with 30cm strip upto 1.5 Mtr height from ground level complete all as specified and directed.
130Supply and fixing automatic street light prewired switch using nature switch for automatic switching of street light based on lux level of nature light.THE SENSOR (NATURE SWITCH) alongwith power contactor for 25 KW 3 phase,MCB pole/wall mountable enclosure made of rust proof electric shock proof terminal proof and FR grade special moulding compound junction box confirming to IP54 with all other accessoried ie lugs cable connedtion etc complete all as specified and directed.
131Supply and fix in replacement non-metallic junction box/street light box with three phase aluminium bus bar of suilable for 415 Volt , 50 Hz electric supply conforming to IP65 wall / pedestral mounted and including MCB SPN 06 Amps complete all as specified and directed.
132Supply and fix steel pole tubular swaged 9 metres long complete with cast iron base plate , finialtaper plug , bolts , nuts and screws as specified type 410 SP-22 complete all as specified and directed.
133Supply and errection in true vertical position 6 mtr long MS pole on pcc foundation suitable for 47 m/s wind speed with 4-8, 590mm PCD of foundation on j anchor bolts consctruction complete with MS base plate of 300mmx300mmx10mm at bottom and swages from base to top in such manner that 114.3mm x 3.65mm upto 3 metres, 88.9mm x 3.25mm upto 1.5 metres , 76.1mm x 3.25mm upto 1.5 metres, above base plate with arm to fix solar street light at top and final tape plug, bolts, nuts, washers and screws incl painting with black bituminous paint two coat over one coat or red oxide primer after errection complete and marking pole number on pole complete all as specified and directed.Note : (i) Earth work and PCC foundation work shall be measured and paid separately.(ii) Description as per direction of Engineer-in-Charge will be printed on each pole without any extra cost.
134Supply and fix in replacement hot dip galvanized decorative pole 6 m height dual arm light fitting outdoor type including 50 watt luminaire with IP66 rating complete all as specified and directed.
135M & L cement concrete in foundation filling and mass concrete type B2 1:3:6 (40mm graded stone aggregate) complete all as specified and directed.
136M & L cement concrete in foundation filling and mass concrete type B2 1:4:8 (40mm graded stone aggregate) complete all as specified and directed.
137Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape with galvanised steel wire or tape and overall PVC sheathed 4 core 10 sq. mm nominal cross section in service connections including takind down old u/s complete all as specified and directed.
138Supply and fixing in repair/replacement of solar street light fittings with integrated 35 Watt LED street light system with solar PV Panel 100 WP, integrated LED fitting with Li-Ion Battery 11.1 V 17 Ah , MPPT based solar charge controller,Motion Sensor and tubular pole of height 5 Mtrs complete all as specified and directed.
139Supply and connecting single core FR, PVC insulated stranded copper conductor cable of size 1.5 sqmm for street light passing through pole hole/GI pipe/PVC conduit to junction box and connected electrically including taking down old unsv wire any type any make complete all as specified and directed.NOTE - Three runs of wire is measured as one RM.
140Supply and fixing in replacement of unserviceable GI tubing medium grade with all fittings complete laid in trenches / on walls / on ceiling / roof etc incl necessary suitable size of MS clamps / saddling on walls / ceiling etc including taking down complete all as specified and directed.
141All as per item No 140 above but 50 mm dia.
142All as per item No 140 above but 25 mm dia.
143All as per item No 140 above but 20 mm dia.
144All as per item No 140 above but 15 mm dia.
145Supply and fix connected Gun metal gate valve ISI marked with iron wheel head screwed both ends for iron pipes and fixed for the following sizes including taking down of unserviceable gate valves complete all as specified and directed.
146All as per item No 145 above but 50 mm dia.
147All as per item No 145 above but 25 mm dia.
148All as per item No 145 above but 20 mm dia.
149All as per item No 145 above but 15 mm dia.
150Supply and fix in replacement amp meter digital type as per existing size and type complete all as specified and directed.
151Supply and fix in replacement volt meter digital type as per existing size and type complete all as specified and directed.
152S & F Volt Meter 0 to 500 Volts digital square type 4” complete all as specified and directed.
153S & F Ammeter 0 to 200 Amps digital Square type 4” complete all as specified and directed.
154S&F in repair CT 30/5 to 200/5 complete all as specified and directed.
155S & F Selector switch for Volt meter /Ampmeter complete all as specified and directed.
156S & F Indicating Lamp set of three (Red , Yellow & Blue) complete all as specified and directed.
157Supply and fix in repairs Decrin dozing pump 100 PSI 40 GPD Capacity and testing complete all as specified and directed.
158Supply and fix in replacement of circuit of speed of Dozing pump complete all as specified and directed.
159Supply and fix in replacement of injector Nozzle of Decrin dozing pump complete all as specified and directed.
160Supply and fix in replacement of Regulator Knob of dozing pump complete all as specified and directed.
161Supply and fix in replacement of power cord of dozing pump 2 mtr long plug top 5 AMP 240 volt AC complete all as specified and directed.
162M&L for rewinding of electric motor 1 HP to 1.5 HP HP 50 Hz 400/415 volts of mono block/centrifugal pump of any make and type with super enameled copper winding wire including bearing bushes and other accessories etc required to make motor functional and testing on load complete all as specified and directed.
163Supply & fixing in repair/replacement of 1HP pressure booster motor with pump as per existing make with head of 10 -50 meters complete all as specified and directed as per ground requirement
164Attending Complaints by deploying sufficient labour for rectification of leakage of UG water pipe lines of size 50 mm bore of any description such as CI/DI/GI pipe line at any location including necessary excavation in any type of soil (approx 2 meter length,width 1.5 meter ,depth 1.5 meter) dewatering complete by using pump set as per site requirement, cutting existing pipe lines including repairs with suitable flanges, Joints or any other material etc complete all as specified and as directed.
165All as per item No 164 above but of size 25/20 mm dia pipe line
166Costruction of valve chamber in PCC 1:5:8 masonry built in CM(1:4) with MS covers 3 mm thick and locking arrangement including excavaton and earth works PCC (1;4;8) type D2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1 plastering 15 mm thick with Cm 1:4 painting with one coat of bituminous black paint on all steel surface , chamber of sizes 900 x 600 x 1000 mm internal dimension complete all as specified and directed.
167Disconnecting & dismantling of pump set from the foundation breaking the existing defective PCC foundation in any size, shape M&L for PCC 1:2:4 type B-2 using 12.5 mm graded aggregate for foundation of any size of motor pump set of 1hp capacity pump set and fitting pumping set in position with base frame painted with synthetic enamel black paint complete all as specified and directed.
168Supply only chlorine test kit with PH colured sample complete with all testing fitment and OT solution in rexine box complete all as specified and directed.
169M&L for chemical and bacteriological analysis of chlorinated water collected from distribution line complete all as specified and directed.
170Supply, Laying, Connecting and testing in repairs cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volt grade cross sectional area 120 Sqmm 3.5 core complete all as specified and directed.
171All as item No 170 above but Size 70 sqmm 3.5 core.
172All as item No 170 above but Size 50 sqmm 3.5 core.
173Boring of Holes under road, Pavement, hard Standing by trenchless technology using ultra Sound technique and necessary machine with HDPE Pipe, PN 10,100 mm dia all as specified and as directed by Engr-In-Charge.
174Supply, laying and fixing in position in repairs galvanized iron pipe 80 mm bore light grade fixed to pole with mild steel clamps of required size or laid through wall/under floor/under road/in trenches duly painted with two coat of black metallic paint after a primer coat of red oxide complete all as Specified and Directed by Engr-In-Charge.
175All as per item No. 11 here in above but 50 mm dia complete all as specified and directed by Engr-In-Charge.
176All as per item No 11 here in above but 40 mm dia complete all as specified and directed by Engr-In-Charge.
177M&L for cable end termination kit out door, heat shrinkable type suitable for XLPE/ PVC cables of size 6 Sqmm to 16sqmm 4 core core with working voltage 1100 volts incl necessary excavation returning filling & removal complete all as specified & directed by Engr-In-Charge make:
178All as above item No 14 but Size 25-35 sqmm 4 core complete.
179All as above item No 14 but Size 50-120 sqmm 3.5 core complete
180M&L for cable jointing kit straight through, heat shrinkable type suitable for XLPE/ PVC cables of size 6 Sqmm to 16 Sqmm 4 core with working voltage 1100 volts, complete all as specified and directed.
181All as above item No 180 above but Size 25-35 sqmm 4 core.
182All as above item No 180 above but Size 50-95 sqmm 3.5 core.
183S&F in repairs MCCB 4 pole 415 volts fixed type 250 Amps with braking capacity 25KA after taking out old U/S one complete all as specified and directed.
184S&F MCCB 4 pole 415 volts in repairs, fixed type 200 Amps with braking capacity 16 KA.after taking out old U/S one complete all as specified and directed.
185S&F in repairs MCCB 3 pole 415 volts fixed type 160 Amps with braking capacity 36KA after taking out old U/S one complete all as specified and directed.
186S&F in repairs MCCB 3 pole 415 volts fixed type 125 Amps with braking capacity 36KA after taking out old U/S one complete all as specified and directed.
187S&F MCCB 3 pole 415 volts in repairs,fixed type 63 Amps with braking capacity 16 KA.after taking out old U/S one complete all as specified and directed.
188S&F sheet metal enclosures DB Double door Verticle distribution type, 06 way, TPN DB , IP43, 415V & suitable for 4 POLE MCCB as incomming including shruded neutral bar & Pan assy with earthing terminal as provided by manufacturer complete all as specified and directed.Note : - MCCB shall be measured and paid separately
189Supply & fixing in replacement of MCB SP 6 t0 32 amps 230 Volt complete all as specified and directed.
190Removing all connections from LT panel having feeders upto 04 Nos ( Total of incoming and outgoing) , any capacity, indoor or outdoor type, fpr repairs/ servicing. Cleaning properly all parts and removing dust, carbon deposits etc. Removing U/S thimbles if any of connections. Refixing serviceable items to the panel and making all connections including testing for proper functioning of the panel as per standard engineering pactice, complete all as specified and directed.. Note:- Old U/S items will be provided against respective items separately.
191M&L for Painting of any size , any make LT panel after removing old dust partical,oily porytion by rubbing with sand paper with spary pump, and writing /digital printing, capacity Descripton, date of installation,etc complete all as specified and directed.
192Supply and fixing as in repair / replacement of UNSV Aluminum thimbles of size 10sqmm to 25sqmm as per site requirements, complete all as specified and directed.
193Supply and fixing as in repair / replacement of UNSV Aluminium thimbles of size 35Sqmm to 70sqmm as per site requirements, complete all as specified and directed.
194M&L danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for LT, 20x15 cm size complete all as specified and directed.
195Supplying and fixing PVC conduit 25 MM dia along with accessories in surface/recess I/C or cutting the wall and making good the same in case of recessed conduit as required complete all as specified and directed.
196Supply, installing testing and commissioning in replacement of size 900*900*450 (Apprx)factory made and tested (Including CPRI test cetified) outdoor type floor mounted LT panel board, cubical type suitable for 415 Volts 3 phase, 4 wire 50Hz, Ac supply system having busbar chamber with insulated AL busbar of rating 1.5 times the incomer MCCB for phase installed on porcelin/SMC insulators. The panel shall be dust and vermin proof IP-64 class protection and made out of 3.15 mm thick CRCA MS sheet and angle iron frame 40x 40x 6mm thick frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coat of red oxide primer, front and back opening type with aproaches for cable entry with double door shutter and locking arrangements including internal wiring with PVC insulated stranded copper conductor cable FRLS IS 694 sheathed 1100V grade of appropriate size comprising of following:-INCOMING-(i) Mains MCCB 4 pole 400 Amps 50 KA with adjustable setting, 415 Volts with breaking capacity 36 KA. -01 No.(ii) Digital type voltmeter 0-500 volts and with selector switch-01 No.(iii) Digital Amp meter with CTs & built in selector switch-01 No.(iv) Indication lamp RYB-01 Set.OUTGOING-(i) MCCB 3 pole 250 Amps,, 415 Volts with breaking capacity 25 KA.-01 No.(ii) MCCB 3 pole 125 Amps, 415 Volts with breaking capacity 25 KA.-03 No. (iii) MCCB 3 pole 100 Amps, 415 Volts with breaking capacity 25 KA.-02 No. Note: Drawings for LT panel shall be got approved from GE before procurement.
197Supply, installing testing and commissioning of wall mounted LT Distribution Board in replacement of size 900*900*300 (Apprx)factory made and tested (Including CPRI test cetified) outdoor type floor mounted LT panel board, cubical type suitable for 415 Volts 3 phase, 4 wire 50Hz, Ac supply system having busbar chamber with insulated AL busbar of rating 1.5 times the incomer MCCB for phase installed on porcelin/SMC insulators. The panel shall be dust and vermin proof IP-64 class protection and made out of 3.15 mm thick CRCA MS sheet and angle iron frame 40x 40x 6mm thick frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coat of red oxide primer, front opening type with down aproaches for cable entry with double door shutter and locking arrangements including internal wiring with PVC insulated stranded copper conductor cable FRLS IS 694 sheathed 1100V grade of appropriate size comprising of following:-INCOMING-(i) Mains MCCB 4 pole 160 Amps 50 KA with adjustable setting, 415 Volts with breaking capacity 36 KA. -01 No.(ii) Digital type voltmeter 0-500 volts and with selector switch-01 No.(iii) Digital Amp meter with CTs & built in selector switch-01 No.(iv) Indication lamp RYB-01 Set.OUTGOING-(i) MCCB 3 pole 250 Amps, 415 Volts with breaking capacity 25 KA.-01 No.(ii) MCCB 3 pole 125 Amps, 415 Volts with breaking capacity 25 KA.-03 No. (iii) MCCB 3 pole 100 Amps, 415 Volts with breaking capacity 25 KA.-02 No. Note: Drawings for LT panel shall be got approved from GE before procurement.
198M & L for earthing with steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less tha 1.5 mtr deep below normal grund level connected to galvanized iron strip size 32 x 6 mm as earthing lead by means of nuts, bolts and washers of steel after wlding of GIstrip to earth electrode to the full length of earht plate, 40mm dia GI tubing lightgrade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover ofsize 30x30 cm made of RCC 1:3: with suitable handle, angle iron frame made of angle iron of size 40x40x4m, adequate qty of charcoal dust and salt layers all around the earth plate and filling of vegetables soil to the remaining 10% removal of surplus soil and retruning filling in all as required at site including test point made outof steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I and complete all as specified and directed.
199M&L for Design ,development ,supply commisiong and testing burnished metallic brown 99.99% pure copper material specially develpoed for earthing purpose T point terminal exothermic/ nut bolt/ breezing . ground tubular effective chemical earthing (CPRI tested for 25KA current capacity for LT line ) highly anticorrosive long life eletrode with and including adequate protective coating to withstand servere weather condition in the earth pit of the standard size comprising of 40 mm 3m long copper rod as primary conductor and hollow copper tube of 80 mmx 3 m long with alosing base plate of 80 mm secondary conductor to install with suitable connecting terminal cofirming of IS 3043 1987 specification highly conductive packing material to be filled in earth pits for providing uniform low resisitivity anticorrosive ,hygroscope medium around the earth system for improving the efficiency of current dissipation with cystalline conductive mixture CCM 25 kg per bag sufficient quantities required at site complete RCC earthing pit cover material and labour complete bfc compound specified and as per ic 62561 acceptance chemical test Leaching, sulphur determination, corrosion, resistivity along with CPRI and chemical compound test report, complete all as specified and directed. Note :-1. Excavation / drilling hole in hard rock is included in the rate quoted incld. T&P2. Min. resistance for earthing pit shall be less than 1 ohm.3. Drilling or earth work shall be included in the overall cost quoted by the contractor.
200Supply and fix copper strip 20mm x 3.15 mm complete with insulators and fixing screws etc for roof/wall above ground level including removing u/s strips complete all as specified and directed.
201Supply and fix aluminium strip 25 mm x 4 mm complete with saddles and fixing screws etc for roof conductors and down conductors above ground level including removing u/s strips complete all as specified and directed.
202Supply and fix single pointed air termination aluminium rod,12 mm dia, 300 mm long all as specified and directed.
203S&F porcelain strip holder on wall and roof of suitable size including removing broken u/s one complete all as specified and directed.
204M&L 32 mm GI pipe light grade of 1.3 mtr piece fixing in PCC cubical and complete connection of existing air termination rod complete all as specified and as directed,
205M&L for PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in coping and necessary form work, weathering slightly rounded or chamfered angles and throating etc complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56275933
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45 Lakhs
LAST DATE 16-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Certain Repair/Maint Of All Type Acs, Dg Sets, Amf Panels, Security /Flood Lights, Ug Pipe Line Including Cleaning/Maint Of Oht Reservoir, Ug Sump, Rising Main Etc And Other E/M Works At Af Stn Aastha Complex & 5 Aflu Under Aor Of Ge(Af) Faridabad
Basic Detail
Tender No GE (FBD)/AF-T-41/2026-2027
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 02 Jul 2026
Submission Date 16 Jul 2026
Open Date 18 Jul 2026
Finance
Tender Value 45 Lakhs
Tender Fee 500
EMD 90000
Exemption Available
Document List
BOQ_868778.xls
e31eedd2-cba3-4e45-a1c9-cb09d8012872.html
Tenderdocu41.pdf
Tendernotice_1 (1).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 02, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Jul 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_868778.xls

html

e31eedd2-cba3-4e45-a1c9-cb09d8012872.html

pdf

Tenderdocu41.pdf

pdf

Tendernotice_1 (1).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders