Tender For Special Rep To Replacement Of Old Earthing Pits , Desert Coolers ,1.5 Ton Acs And Provn Of Three Phase Connection For Kitchen(Fatehgunj) & Fvt Kitchen(Harni), Eme School Vadodara.
Tender Value
27.82 Lakhs
Estimated cost
Bid Submission
22 Jul 2026
16 days left
EMD
55640
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Vadodara → Gujarat
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Rep To Replacement Of Old Earthing Pits , Desert Coolers ,1.5 Ton Acs And Provn Of Three Phase Connection For Kitchen(Fatehgunj) & Fvt Kitchen(Harni), Eme School Vadodara.
BOQ
| Sl. No. | Item Description |
| 1 | M & L Earthing Complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.5 metre below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using earth strip 25 x 4 mm by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and other end of the earth wire connected to main switch board protected by galvanised iron medium grade pipe 40mm bore in wall/floor/and GI Pipe 20 mm bore light grade for watering with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC pit cover including necessary excavation and earth work in any type of soil, returning slurry approved soil and disposed of surplus soil to a distance not exceeding 50 Mtr away all as shown in electrical plate No 3 of SSR 2009 ( Part-I).Notes (a) The unit rate shall include for GI protection pipe, GI watering pipe, wire mesh, funnel and excavation, RCC pit cover, test point, galvanised iron strip from top of earth plate upto 7.5 metres above ground level and if GI protection pipe is less than 7.5 metres, no price adjustment shall be made.(b) PCC pit shall be provided at least 50cm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junction, elbow etc shall be deemed to be included in the unit rate.(c) If the testing result of earthing work is not found below 3 Ω then the contractor shall do another earthing work at his own cost and nothing shall be permissible on this account.(d) Earthing work will be carried out in presence of MES representative. |
| 2 | M&L Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground |
| 3 | M&L Aluminnium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground |
| 4 | M&L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified |
| 5 | Supply and fix RCC Earth Pit Chamber with outer size of chamber 450mm x 450 mm,Inner clear size 350mm x 350 mm ,wall thickness 50mm,RCC Cover 400 x 400 x 50 mm cover ,manufactured using M25 grade concrete,suitable for electrical earthing application.The chamber is designed for durability,strenth and long service life under ground installation condition . |
| 6 | S & F RCCBOs for earth leakage current, overload & short- circuit protection Double pole, 100mA,6 to 32 Amps 240/440 Volt,50 Hz,conforming to IEC 61008-1/IS 12640-1 standards all as specified and directed by EIC. |
| 7 | S & F RCCBOs for earth leakage current, overload & short- circuit protection Double pole, 100mA,40 to 63 Amps 240/440 Volt,50 Hz,conforming to IEC 61008-1/IS 12640-1 standards all as specified and directed by EIC. |
| 8 | S & F RCCBOs for earth leakage current, overload & short- circuit protection Four pole, 100mA,16 to 32 Amps 240/440 Volt,50 Hz,conforming to IEC 61008-1/IS 12640-1 standards all as specified and directed by EIC. |
| 9 | S & F RCCBOs for earth leakage current, overload & short- circuit protection Four pole, 100mA,40 to 63 Amps as ordered 240 Volts 240/440 Volt,50 Hz,conforming to IEC 61008-1/IS 12640-1 standards all as specified and directed by EIC. |
| 10 | S & F RCCBOs for earth leakage current, overload & short- circuit protection Four pole, 300mA,16 to 32 Amps as ordered 240 Volts 240/440 Volt,50 Hz,conforming to IEC 61008-1/IS 12640-1 standards all as specified and directed by EIC. |
| 11 | S & F RCCBOs for earth leakage current, overload & short- circuit protection Four pole, 300mA,40 to 63 Amps as ordered 240 Volts 240/440 Volt,50 Hz,conforming to IEC 61008-1/IS 12640-1 standards all as specified and directed by EIC. Please Enable Macros to View BoQ information |
| 12 | S & F RCCBOs for earth leakage current, overload & short- circuit protection Four pole, 300mA,40 to 63 Amps as ordered 240 Volts 240/440 Volt,50 Hz,conforming to IEC 61008-1/IS 12640-1 standards all as specified and directed by EIC. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 02, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysJul 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer