Tender For 8678 - Maintenance And Repairs/Replacement Of Ht Cable, Acbs Mccbs, Earthings, Apfc Panels, Lt Feeders Boxes And Connected Accessories At Drdl Kalinga Under Age (I) R&D Nstl, Visakhapatnam
Tender Value
9.90 Lakhs
Estimated cost
Bid Submission
23 Jul 2026
16 days left
EMD
19800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Visakhapatanam → Andhra Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for 8678 - Maintenance And Repairs/Replacement Of Ht Cable, Acbs Mccbs, Earthings, Apfc Panels, Lt Feeders Boxes And Connected Accessories At Drdl Kalinga Under Age (I) R&D Nstl, Visakhapatnam
BOQ
| Sl. No. | Item Description |
| 1 | M & L for taking down the damaged / un serviceable Lighting arresters expulsion type suitable for 11000 volts complete with all fittings,transmission class,discharge capacity 6.5 Kilo AmpsMake: HTSG /JAIPURIA |
| 2 | Supply and fix single core 2.5 sqmm cable with copper conductor PVC round sheathed (flexible) industrial control for connections from CTs to relay control panel of capacity 11 KV and 433 KV including all necessary connections required, testing of relay after completing for proper functioning complete all as specified and as directed. |
| 3 | M&L for isolating, cutting, removing the existing damaged end termination and S&F outdoor end termination heat shrink outdoor type (Earthed) suitable for HT UG cable XLPE insulated 3 Core 120 to 185 Sqmm 11KV grade including preparation complete all as directed. (Make: REPL/3M/Raychem) |
| 4 | M&L for isolating, cutting, removing the existing damaged end termination and S&F outdoor end termination heat shrink outdoor type (Earthed) suitable for HT UG cable XLPE insulated 3 Core 240 to 300 Sqmm 11KV grade including preparation complete all as directed. (Make: REPL/3M/Raychem) |
| 5 | M&L for cutting, removing the existing damaged joint and S&F straight through joint heat shrinkable type suitable for HT UG cable XLPE insulalted 3 core 120 to 185 sqmm 11000V grade including preparation complete all as directed (Make:Raychem/ REPL/ Denson). |
| 6 | M&L for cutting, removing the existing damaged joint and S&F straight through joint heat shrinkable type suitable for HT UG cable XLPE insulalted 3 core 240 to 400 sqmm 11000V grade including preparation complete all as directed (Make:Raychem/ REPL/ Denson). |
| 7 | Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre depth for route of cable and getting out complete all as specified and as directed by the Engineer-in-Charge. |
| 8 | Returning, filling in soft/loose soil including spreading, leveling, watering and well ramming, in layers not exc 25 cm complete all as specified and as directed by the Engineer-in-Charge. |
| 9 | Removing of surplus soil to a distance not exc. 50 metre and depositing where directed at a level not exc.1.5 metre above the starting point complete all as specified and as directed by the Engineer-in-Charge. |
| 10 | M & L for dry sand cushioning and cover for protection of cable, complete all as specified and as directed by the Engineer-in-Charge. (Note: Approved local tibba dry sand after removal of vegetations, grass and other deleterious substances shall be used for sand cushioning and cover). |
| 11 | M & L for taking down 11 KV grade unserviceable Pin/post insulators from the HT 2 pole/4 pole structure and S&F pin type composite insulation/silicon rubber material including one galvanishing MS spingle, nuts & washers of 150mm height, 150 mm dia for 11000 volt grade and fixing to the structure and binding of conductor all as directed.Make: GK Electricals /Jaipuria/ ABI |
| 12 | Supply and Fixing in replacement Cross linked poly-ethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric earthed power cables ( heavy duty) with aluminium conductor, 1100 volts grade of cross-sectional area 25 Sqmm 3.5 core conforming to IS-7098 (Part-I) laid in trenches/through pipe in road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etc. complete supply and fixed/ laid all as specified and as directed by Engineer-in-Charge.( Note:-(i) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately. ) Make : Gloster/Havells/polcab |
| 13 | All as per item above but size of cable 50 sqmm 3.5 core all as specified and directed. Make Gloster/Havells/polycab |
| 14 | Supply and laying un-rainforce, precast concrete cable cover class LV, type-I of size 250 mm x 150 mm x 40mm all as specified and directed by Engineer-in-Charge. |
| 15 | Material and labour for Earthing complete with Copper plate electrode 60 x 60 x 3.15mm thick electrode copper strip as earthing lead mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below ground level connected to galvanised Copper 20x3 mm size by means of nuts, bolts, check nuts and washers of the galvanised iron or steel all as shown in electrical plate No 5 connected to earthing test point including watering arrangement with PCC 1:3:6 type C1 chamber, MS Funnel, Wire Guage, 50 mm thick precast RCC Coverin Type B1 including necessary excavationin any type of soil, returning, filling in, removal of surplus soil to a distance n exc 50 m, char coal and salt complete all as shoen in electrical Plate No. 3of SSR Part-1 2009 and conecting to earth test point all as specified and as directed. Note : Contractor should submit test results of earthings. |
| 16 | M&L Earthing continuity copper strip 20x3.15 mm dia or main earthing lead fixed to wall with clamps or recess or croses or buried in ground or drawn in conduits/pipe or fixed to poles or any other indicated situation for loop earthing etc as required all as specified and directed by Engr-in-Charge. |
| 17 | Supply and fixing in repair MCCB, AC 415 V, 50 HZ, fixed type, capacity 400 Amps, 4 Pole, 36 KA, suitable to be fixed in LT panel complete all as specified and directed Make: L&T/HAVELLS/SCHIENDER/ABB/SIEMENS/LEAGRAND |
| 18 | All as per item above but of capacity 250 amps 36 KA. |
| 19 | All as per item above but of capacity 160 amps 36 KA . |
| 20 | All as per item above but of capacity 100 amps 16 KA 3 pole. |
| 21 | GI Tubing light grade 40 mm dia for cable protection, laid under plinths/floors /roads /culverts or fixed on walls or concealed in walls or along the steel poles by means of M.S.F.I clamps with necessary bolts nuts washers etc Including taking down old u/s pipe complete all as specified. |
| 22 | Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m. Including taking down of old existing mat. |
| 23 | Material & Labour for opening of existing APFC panel by disconecting the electric supply for cleaning and Servicing of APFC Panel including checking all connections, find out faults for required power factor,checking control wiring circuit, replacement of control wiring if required, Replacement of spares like contactors, Capacitors,CT's,PF controller and commissioning and testing of APFC panel after repair work to achieve required unity power factor including relay calibration for auto and manual function complete all as specified and as directed by Engineer-in-charge.Note: Spares like contactors, capacitors, relays and CTs are measured and paid separately under appropriate items. |
| 24 | Supply only Power capacitor cylindrical type super heavy duty 440 V, 50 Hz , 3 phase, AC having of capacity 10 KVAR all as specified and as directed. Make : Havells/L&T/Neptune power/EPCOS |
| 25 | All as per item above here in above but of capacity 12.5 KVAR all as directed. |
| 26 | All as per item above here in above but of capacity 20 KVAR all as directed. |
| 27 | All as per item above here in above but of capacity 25 KVAR all as directed. |
| 28 | All as per item above here in above but of capacity 50 KVAR all as directed. |
| 29 | Supply only Power contactor suitable for 10 Kvar capacitor 440 V, 50 Hz , 3-ph, AC having of capacity 10 KVAR all as specified and as directed. Make : L&T Cat No.MO C10 (CS96156) or equivalent of Havells / Epocs/Neptune Power |
| 30 | All as per item above but suitable for 12.5 KVAR capacitor all as directed.Make : L&T Cat No.MO C12.5 (CS96321) or equivalent of Havells / Epocs/Neptune Power |
| 31 | All as per item above but suitable for 20 KVAR capacitor all as directed.Make : L&T Cat No.MO C20 (CS90021) or equivalent of Havells / Epocs/Neptune Power |
| 32 | All as per item above but suitable for 25 KVAR capacitor all as directed.Make : L&T Cat No.MO C25 (CS96322) or equivalent of Havells / Epocs/Neptune Power |
| 33 | All as per item above but suitable for 50 KVAR capacitor all as directed.Make : L&T Cat No.MO C50 (CS96324) or equivalent of Havells / Epocs/Neptune Power |
| 34 | All as per item above but 120A capacitor all as directed.Make : L&T Cat No.MO C50 (CS96324) or equivalent of Havells / Epocs/Neptune Power |
| 35 | Supply and fixing in replacement of APFC controller relay for Contactor switching with 1 CT input 415V single CT of size 96 x 96 mm suitable for Contactor Switching 8 stages with Auto programming function,smart controller all as specified and directed. Make L&T Cat No.CS90902OOOO or equivalent of Havells / Epocs/Neptune Power |
| 36 | Supply only current transformer suitable for APFC Panel for current sensing of capacity 25 A/ 5 A complete all as specified and directed by Engr in charge.Make :-Havells Cat NoQSCELMLX0002 |
| 37 | Supply only closing coil assembly 110v DC for VCB all as specified & directed.Make :- Alstom/schnider |
| 38 | Supply only fix tripping coil 110V DC for VCB all as specified & directed.Make :- Alstom / English Electric/Schnider |
| 39 | Supply only 11 Kv PT HV Back up fuse cat no 12Kv ABCNA 3.15A 38/10 as per OEM Recomendation / Make: Schnider/Bussmann |
| 40 | Supply only space/ strip heaters of 1 KW, 220Volts for VCBs all as specified and directed. |
| 41 | Repairs to Spring Charging motors of capacity 230 V AC/DC Universal with gear box for VCB of 11/ 433 KV of suitable size and capacity for existing VCB as recommended by OEM complete all as specified and as directed by Engineer-in-charge. |
| 42 | Supply and fix in replacement of Breaker control switch of capacity 25A, 3-position (Trip/ Neutral/ Close) Suttable for 11KV VCB brakears all as directed and specifed by Engr in Charge. |
| 43 | M & L opening the bus bar and rear panel of LT Panel board (01 Nos incoming and upto 06 Nos outgoing), disconnecting the cables from the busbars, replacement of suitable size of aluminium lugs of various size through desired method, replacement of burnt out nuts/bolts, replacement of cable glands, replacement of internal wiring, replacement of partially burnt out bus bar (if required) taking down carefully the copper/aluminium bus bar as required at site, scrapping the bus bar by emery paper for removing the silt/carbon, replacement of PVC insulation tape (RYB),and taking down the rusted portion of door including removing bends/dents,refixing the door with new hinges,handles,nut bolts making good to disturb area & complete assembling the bus bar, LT Panel board complete for testing all as specified and directed by Engr-in-charge. |
| 44 | M &L for preparation of old painted surface of Bas bar chember, ACBs, APFC panel, LT panel boards/feeder pillar boxes consoles etc external & internal surfaces of by scrubbing/CTC by emary paper by removing stains/rusted scales etc and applying two coats of synthetic enamel paint as colour approved by Engr-in-charge over a one coat of zinc oxide primer complete and cleaning meters/indicators/MES Nos,making good complete all as specified and directed by Engr-in-charge. |
| 45 | M &L for repairs to LT panels/Feeder pillar boxes/cope point box by opening door hinges and taking down the rusted portion of door including removing bends/dents,refixing the door with new hinges,handles,nut bolts making good to disturb area complete all as pecified and directed by Engr-in-charge. |
| 46 | M&L for PCC earth pit cover suitable as per site requirement making good to disturb area complete as specified and directed by Engr-in-charge. |
| 47 | Supply only Aluminium lugs suitable for XLPE UG cable size of 10/16/25 sq mm |
| 48 | Supply only Aluminium lugs suitable for XLPE UG cable size of 35/50 sq mm |
| 49 | Supply only Aluminium lugs suitable for XLPE UG cable size of 70/95/120 sq mm |
| 50 | Supply only Aluminium lugs suitable for XLPE UG cable size of 185/240 sq mm |
| 51 | M & L for pin pointing fault of faulty 11 KV HT cables by using HT cable fault locator machine,removing the fault and testing HT Cable at 11 KV complete Job all as specified and as directed by the Engineer-in-Charge. |
| 52 | S & F in repairs Digital LT voltmeter with inbuilt selector switch of size 96x 96mm rating 0 to 500 volt all as specified and directed. Make:LT cat No.WL132010OOOO or equivalent in AEI,IMP,MECO,MEI,HPL,SIEMENS |
| 53 | S&F in repairs Digital LT Ammeter with inbuilt selector switch of size 96x 96mm suitable for CT ratio 5amp, progaramable type and all as specified and directed. Make:LT cat No.WL132020OOOOor equivalent in AEI,IMP,MECO,MEI,HPL,SIEMENS |
| 54 | S&F in repairs indicating lamp holder with bulb LED(Red Yellow,Blue,Green) type to indicate incoming supply suitable for 24 V DC/110 VAC/230Volts AC and all as specified and directed. Make: C&S /L&T/SCHIENDER/AEI/IMP/JYOTI/KAYPEE/VAISHNAVI/SIEMENS Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 02, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysJul 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender