Defence Statutory Bodies & Commissions/Committees Closing in 15 days TDR #56275840

Tender For Maint/Repair/Replacement Of Lt Cable Distribution System And Allied Works Of West Area Under Ge (W) Bareilly.

Issued by Statutory Bodies & Commissions/Committees · Bareilly, Uttar Pradesh
Tender Value
36 Lakhs
Estimated cost
Bid Submission
23 Jul 2026
15 days left
EMD
72000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bareilly → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Maint/Repair/Replacement Of Lt Cable Distribution System And Allied Works Of West Area Under Ge (W) Bareilly.

BOQ

Name of Work:- Maint/Repair/Replacement of LT cable distribution system and allied works of west area under GE (W) Bareilly.
Sl. No. Item Description
1Excavation in trenches n. exc. 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed.
2Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
3Removing of excavated soil to a distance not exceeding 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
4M&L Local sand dry, filling in trenches around under ground cable complete all as specified and directed.
5M&L for providing of new sub class 'B' Bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.
6Laying only old bricks complete all as specified and directed.
7S&F in replacement GI pipe light grade for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc of following sizes complete all as specified & directed. 40 mm bore
8S&F in replacement GI pipe light grade for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc of following sizes complete all as specified & directed. 50 mm bore.
9S&F in replacement GI pipe light grade for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc of following sizes complete all as specified & directed. 80 mm bore
10Taking out old unserviceable LT Cable any type and size from trenches or fixed on poles or through pipes/walls/laid under roads/paths/ drains/culverts complete all as specified and directed.
11Supply, laying, jointing and testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty, conforming to IS - 7098 Part I -1988 with aluminum conductor 1100 Volts of following sizes / grade laid in ducts or on walls, in trenches encased in GI pipe fixed to walls / laid under roads / drains / paths / culverts etc complete all as specified and directed. 10 Sqmm 2 core
12Supply, laying, jointing and testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty, conforming to IS - 7098 Part I -1988 with aluminum conductor 1100 Volts of following sizes / grade laid in ducts or on walls, in trenches encased in GI pipe fixed to walls / laid under roads / drains / paths / culverts etc complete all as specified and directed. 16 Sqmm 4 core
13Supply, laying, jointing and testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty, conforming to IS - 7098 Part I -1988 with aluminum conductor 1100 Volts of following sizes / grade laid in ducts or on walls, in trenches encased in GI pipe fixed to walls / laid under roads / drains / paths / culverts etc complete all as specified and directed. 25 Sqmm 4 core
14Supply, laying, jointing and testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty, conforming to IS - 7098 Part I -1988 with aluminum conductor 1100 Volts of following sizes / grade laid in ducts or on walls, in trenches encased in GI pipe fixed to walls / laid under roads / drains / paths / culverts etc complete all as specified and directed. 35 Sqmm 3.5 core
15Supply, laying, jointing and testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty, conforming to IS - 7098 Part I -1988 with aluminum conductor 1100 Volts of following sizes / grade laid in ducts or on walls, in trenches encased in GI pipe fixed to walls / laid under roads / drains / paths / culverts etc complete all as specified and directed. 50 Sqmm 3.5 core
16Supply, laying, jointing and testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty, conforming to IS - 7098 Part I -1988 with aluminum conductor 1100 Volts of following sizes / grade laid in ducts or on walls, in trenches encased in GI pipe fixed to walls / laid under roads / drains / paths / culverts etc complete all as specified and directed. 95 Sqmm 3.5 core
17Supply, laying, jointing and testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty, conforming to IS - 7098 Part I -1988 with aluminum conductor 1100 Volts of following sizes / grade laid in ducts or on walls, in trenches encased in GI pipe fixed to walls / laid under roads / drains / paths / culverts etc complete all as specified and directed. 150 Sqmm 3.5 core
18Supply, laying, jointing and testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty, conforming to IS - 7098 Part I -1988 with aluminum conductor 1100 Volts of following sizes / grade laid in ducts or on walls, in trenches encased in GI pipe fixed to walls / laid under roads / drains / paths / culverts etc complete all as specified and directed. 185 Sqmm 3.5 core
19Supply, laying, jointing and testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty, conforming to IS - 7098 Part I -1988 with aluminum conductor 1100 Volts of following sizes / grade laid in ducts or on walls, in trenches encased in GI pipe fixed to walls / laid under roads / drains / paths / culverts etc complete all as specified and directed. 240 Sqmm 3.5 core
20Supply, laying, jointing and testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty, conforming to IS - 7098 Part I -1988 with aluminum conductor 1100 Volts of following sizes / grade laid in ducts or on walls, in trenches encased in GI pipe fixed to walls / laid under roads / drains / paths / culverts etc complete all as specified and directed. 400 Sqmm 3.5 core
21Relaying only serviceable LT UG Cable obtained from existing of any size and discription including necessary cable lugs. ( All relevent items like excavation, earth work, sand cushionning, bricks etc shall be measured seperatly under respective item of Sch.)
22S&F Heat shrinkable straight through Jointing Kit suitable for 1100 volts grade XLPE insulated stranded aluminium conductor cable including testing on completion complete all as specified and directed by the Engr-in-Charge for the following size of cables :- 10 Sqmm to 16 sqmm 4 core
23S&F Heat shrinkable straight through Jointing Kit suitable for 1100 volts grade XLPE insulated stranded aluminium conductor cable including testing on completion complete all as specified and directed by the Engr-in-Charge for the following size of cables :- 25 Sqmm to 50 sqmm 3.5/4 core
24S&F Heat shrinkable straight through Jointing Kit suitable for 1100 volts grade XLPE insulated stranded aluminium conductor cable including testing on completion complete all as specified and directed by the Engr-in-Charge for the following size of cables :- 70 sqmm to 150 sqmm, 3.5 core
25S&F Heat shrinkable straight through Jointing Kit suitable for 1100 volts grade XLPE insulated stranded aluminium conductor cable including testing on completion complete all as specified and directed by the Engr-in-Charge for the following size of cables :- 185 sqmm to 240 sqmm, 3.5 core
26S&F Heat shrinkable straight through Jointing Kit suitable for 1100 volts grade XLPE insulated stranded aluminium conductor cable including testing on completion complete all as specified and directed by the Engr-in-Charge for the following size of cables :- 300 sqmm to 400 sqmm, 3.5 core
27M&L in repairs of of MCB, TPN, 40 Amp, C - Curve 415 Volts, 50 Hz, including taking down old unsv Complete all as specified and directed.
28M&L in repairs of of MCB, TPN, 63 Amp, C - Curve 415 Volts, 50 Hz, including taking down old unsv Complete all as specified and directed.
29M&L in repairs of of MCB, SP, 6-32 Amp, C - Curve, 240 Volts, 50 Hz, including taking down old unsv Complete all as specified and directed.
30S&F in repairs of MCCB 4 Pole, 415 V, 630 Amps with Microprocessor based release breaking capacity 50 KA, Ics=100% of Icu with copper spreader incl taking down existing MCCB complete all as specified and directed.
31S&F in repairs of MCCB 4 Pole, 415 V, 400 Amps with Microprocessor based release breaking capacity 36 KA, Ics=100% of Icu with copper spreader incl taking down existing MCCB complete all as specified and directed
32S&F in repairs of MCCB 4 Pole, 415 V, 250 Amps with Microprocessor based release breaking capacity 36 KA, Ics=100% of Icu with copper spreader incl taking down existing MCCB complete all as specified and directed
33S&F in repairs of MCCB 4 Pole, 415 V, 160 Amps with Microprocessor based release breaking capacity 36 KA, Ics=100% of Icu with copper spreader incl taking down existing MCCB complete all as specified and directed
34S&F in repairs of MCCB 4 Pole, 415 V, 200 Amps with adjustable type, breaking capacity 36 KA, Ics=100% of Icu with Copper spreader incl taking down existing MCCB complete all as specified and directed
35M&L PCC 1:4:8 type D2 (using 40 mm graded aggregate) as in foundation filling and mass concrete complete all as specified and directed.
36Taking out carefully interlocking paver block, of any size or shape and re-laying in the same position after removing all vegetation, algae, grass etc., laid in proper slope and gradient over sand cushioning, complete all as specified and directed.
37Supply and fixing Machine pressed precast concrete interlocking paver block with grey cement and pigment of any shape and size as approved by GE conforming to IS-15658-2006 of 80 mm thickness, M-35 grade with 6 mm top layer of coloured rubberised anti abrasive material complete all as specified and directed.
38M&L in replacement Earthing complete with Galvanised iron earth plate electrode 600mm x 600mm x 6mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below ground level connected with GI wire 4.00 dia connected with nuts, bots, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 25mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (reinforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not esceeding 50 Mtr etc all as shown on electrical plate No.3 of MES Schedule Part-I complete and testing on completion complete all as specified and as directed by the Engineer-in-Charge.
39M&L in replacement Earthing complete with Galvanised iron earth plate electrode 600mm x 600mm x 6mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below ground level connected with galvanised earthing strip of size 25mm x 4mm by means of nuts, bots, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (reinforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not esceeding 50 Mtr etc all as shown on electrical plate No.3 of MES Schedule Part-I complete and testing on completion complete all as specified and as directed by the Engineer-in-Charge.
40M&L in repairs of Earth continuity conductor or main earthing lead 4mm dia fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire, complete all as specified and as directed.
41M&L in repairs for Galvanized Iron Strip of size 25mm x 4.00 mm fixed to wall or on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and as directed by Engineer-in-Charge.
42M&L for cleaning and preparation of old painted surface of LT steel tubular pole complete and painting with one coat of aluminium paint including channels/brackets, street light brackets, cross arms and making Black/Red/Yellow & white strips with synthetic enamelled paint of 30cm height, each alternative strip upto 1.5 mtr height and writing pole numbers with yellow synthetic enamelled paint after making circular base with black synthetic enamelled paint and applying two coat of white wash on PCC coping complete all as specified and directed by Engr-in-charge.
43Dismantling of cross arms of MS channel or angle sections etc complete and setting aside for re-use with in 50 mtr complete all as specified and directed.
44Dismantling insulators any type any size from LT poles all as specified and directed by Engineer -in-Charge.
45M&L for Pin type , porcelain, vitreous, white, borwn or green insulator including one galvanised mild steel spindle , two galvanised mild steel spindle, two galnvanised iron wahers and one galvanised iron nut, 100 mm height, 65 mm dia. complete all as specified and directed.
46Dismantling of ACSR from the poles all as specified and directed by Engineer -in-Charge. complete all as specified and directed.
47M&L Aluminium conductor, steel reinforced including stringing in position all as specified and directed by Engineer -in-Charge.
48S&F in repairs PVC LT OH line spacer for 5 wires complete all as specified and directed.
49S&F in repairs PVC LT OH line spacer for 4 wires complete all as specified and directed.
50S&F in repairs PVC LT OH line spacer for 3 wires complete all as specified and directed.
51M&L Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers welding, bending cold or hot, drilling holes for bolts, in any hape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
52S&F in repair 1100 Volts grade heavy duty cable, flat or circular PVC insulated aluminium stranded conductor of following sizes served with inner sheathing of PVC tapes and overall PVC sheathed in service connection from pole to Main Switch complete all as specified and directed. 6 sqmm twin core
53S&F in repair 1100 Volts grade heavy duty cable, flat or circular PVC insulated aluminium stranded conductor of following sizes served with inner sheathing of PVC tapes and overall PVC sheathed in service connection from pole to Main Switch complete all as specified and directed. 10 sqmm twin core
54M&L fabrication of MS busbar chamber of nominal dimension 900 mm x 600 mm x 400 mm duly provided with aluminimum busbar of size 50 mm x 6 mm duly wraped with RYB sleeves and fixed on porcelain insulators TPN type out door weather/vermin proof with both way opening with locking arrangement duly provided with neoprene rubber gasket along the doors openings pedestal type duly painted powder coated on CRCA steel sheet encloser 2 mm thick with one No incommer MCCB 160 Amp 25 KA including making connection /thimbles including taking down old unserviceable busbar chamber complete all as sepcified and directed
55All as per srl item 54 above here-in-before but of size 600 mm x 600 mm x 300 mm and without MCCB and bus bar rating 400 amp including taking down old unserviceable busbar chamber complete all as specified and directed. Please Enable Macros to View BoQ information
56All as per srl item 54 above here-in-before but of size 600 mm x 600 mm x 300 mm and without MCCB and bus bar rating 400 amp including taking down old unserviceable busbar chamber complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56275840
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 36 Lakhs
LAST DATE 23-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Maint/Repair/Replacement Of Lt Cable Distribution System And Allied Works Of West Area Under Ge (W) Bareilly.
Basic Detail
Tender No 8392/C/E8
Bidding Type Tender
Location
City Bareilly
State Uttar Pradesh
Key Dates
Publish Date 02 Jul 2026
Submission Date 23 Jul 2026
Open Date 25 Jul 2026
Finance
Tender Value 36 Lakhs
Tender Fee 500
EMD 72000
Exemption Available
Document List
a1aa3911-e4af-434f-bd20-9eb20bcaa86d.html
BOQ_869015.xls
COMPLETETENDER8392.pdf
Tendernotice_1 (1).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 02, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Jul 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
html

a1aa3911-e4af-434f-bd20-9eb20bcaa86d.html

xls

BOQ_869015.xls

pdf

COMPLETETENDER8392.pdf

pdf

Tendernotice_1 (1).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender