Housing Urban and Rular Development Government Departments Closing in 15 days TDR #56275529

Tender For Construction Of Additional District & Session Court Building At Chalisgaon, Dist. Jalgaon

Issued by Government Departments · Jalgaon, Maharashtra
Tender Value
102.99 Crore
Estimated cost
Bid Submission
23 Jul 2026
15 days left
EMD
51.50 Lakhs
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jalgaon → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Additional District & Session Court Building At Chalisgaon, Dist. Jalgaon

BOQ

Name of Work:- Construction of Additional District & Session Court Building at Chalisgaon, Dist. Jalgaon
Sl. No. Item Description
1Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 millimetre, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 millimetre in thickness.
2Providing detailed layout plan of area in scale 1:500 including carrying out contour survey and detailed Engineering plane table Survey with the help of 24\\" Alidade. The dolomite area measurement of the plot and structures, trees, over head line and under ground service amenities within the area, with triangular method and giving detailes of the structures, such as total area, type of building and distance from all corners taking trial pit 0.5 X 0.5 X 2.00 metre - 2 Numbers per acre and collection of record from city survey / D.I.L.R. authorities and authentication. The plan shall be traced on 75 micron polyster film and shall be submitted along with three Amonia prints. The contour levels shall be marked at 0.5 Meter intervals. Note:- The items includes- 1) Traversing work with theodolite and steel tape. 2) Levelling Grid Work of the terrain. 3) Detailed Engineering Survey and contouring work of the terrain. 4) Plotting work. 5) Collection of Record. a) Above to 1 Acre.
3Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 metre)
4Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0 mtere.)
5Excavation for foundation in Hard murum and boulders including removing the excavated material upto a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 metre to 3.0 metre)
6Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 1.5metre To 3.0 metre)
7Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etc. including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramming etc. complete. (Lift upto 1.5 metres).
8Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite / quartzite / gneiss metal for foundation and bedding / steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical Shaft Impactor Grade)
9Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50 metre and spreading for embankment or stacking as directed.
10Excavation for roadway in hard murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50metre and spreading for embankment or stacking as directed.
11Providing earth work in embankment with approved materials obtained from departmental land upto lead of 50 metre including all lifts, laying in layers of 20 centimetre to 30 centimetre thickness breaking clods, dressing to the required lines, curves, grades & section, watering and compaction with vibratory roller to achieve not less than 97 percent of standard proctor density etc. complete. (Material obtained from departmental Land)
12Providing and laying Cast in situ / Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical Shaft Impactor Grade etc)
13Filling in plinth and floors with approved excavated material in 15 centimetre to 20 centimetre layers including watering and compacting etc. complete. Spec. No. : Bd.A. 11/Page No. 262
14Filling in plinth and floors with contractors material/brought from outside and approved by Engineer in charge in layers of 15 centimetre to 20 centimetre. including watering and compaction etc. complete. Spec. No. : Bd.A. 11/Page No. 263
15Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 centimetre to 20 centimetre thick including hand packing and compacting etc. complete.
16Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper.
17Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 0.5 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper. ( AS per Item no. 22.43 of schedule of rates of NBO )
18Providing and fixing in position HCRM / CRS (Corrosion Resistant Steel) bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
19(A) Ground Floor
20Providing and laying in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etc. including bailing out water, formwork, laying / pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade)
21Providing and laying Cast in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade)
22(A) Ground Floor
23(B) First Floor
24(C) Second Floor
25(D) Third Floor
26(E) Fourth Floor
27(F) Fifth Floor
28Providing and casting in situ cement concrete M-25 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete beams and lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks compaction and roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled concrete batch mix plant (pan mixer). With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade)
29(A) Ground Floor
30(B) First Floor
31(C) Second Floor
32(D) Third Floor
33(E) Fourth Floor
34(F) Fifth Floor
35Providing and laying Cast in situ / Ready Mix cement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete chajja as per detailed design and drawings including centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/Vertical Shaft ImpactorGrade. quality Artificial Sand
36(A) Ground Floor
37(B) First Floor
38(C) Second Floor
39(D) Third Floor
40(E) Fourth Floor
41(F) Fifth Floor
42Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for Reinforced Cement Concrete slabs and landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade)
43(A) Ground Floor
44(B) First Floor
45(C) Second Floor
46(D) Third Floor
47(E) Fourth Floor
48(F) Fifth Floor
49Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete pardi of required thickness including centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and rougheningthem if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade)
50(A) Ground Floor
51(B) First Floor
52(C) Second Floor
53(D) Third Floor
54(E) Fourth Floor
55(F) Fifth Floor
56Providing and laying Cast in situ / Ready Mix cement concrete in M-25 of trap / quartzite /granite /gneiss metal for Reinforced Cement Concrete Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying / pumping, compaction, finishing uneven and honeycombed surface with Cement Mortor 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.With natural sand/Vertical Shaft Impactor quality Artificial Sand
57(A) Ground Floor
58(B) First Floor
59(C) Second Floor
60(D) Third Floor
61(E) Fourth Floor
62(F) Fifth Floor
63Providing and fixing during laying in Reinforced Cement concrete Slab rectangular 2 millimetre thick Mild Steel sheet fan hook box of size 180 X 100 millimetre with required depth with holes or notches as required, bottom and top sides of 1.6 millimetre Mild Steel sheet fixed with 3.5 millimetre diametre round headed screws together with 12 millimetre diametre Mild Steel bar bent to shape with hooked ends for fan hook and painting to exposed surface
64(A) Ground Floor
65(B) First Floor
66(C) Second Floor
67(D) Third Floor
68(E) Fourth Floor
69(F) Fifth Floor
70Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including centering, formwork, cover blocks, laying / pumping, compacting, curing, finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade)
71(B) First Floor
72(D) Third Floor
73(F) Fifth Floor
74Providing and fixing in position Thermo Mechanically Treated - FE - 500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
75(A) Ground Floor
76(B) First Floor
77(C) Second Floor
78(D) Third Floor
79(E) Fourth Floor
80(F) Fifth Floor
81Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.
82(F) Fifth Floor
83Providing second class Burnt Brick masonry with conventional/ Indian Standard type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete.
84Providing second class Burnt Brick masonry with conventional/ Indian Standard type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete
85(A) Ground Floor
86(B) First Floor
87(C) Second Floor
88(D) Third Floor
89(E) Fourth Floor
90(F) Fifth Floor
91Providing second class Burnt Brick masonry with conventional/ Indian Standard type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 millimetre diameter / 2 hoop iron strips 25 millimetre X 1.6 millimetre placed at every third course, properly bent and bonded at ends scaffolding, racking out joints and watering etc. complete.
92(A) Ground Floor
93Providing internal cement plaster 12 millimetre thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete.
94(A) Ground Floor
95(B) First Floor
96(C) Second Floor
97(D) Third Floor
98(E) Fourth Floor
99(F) Fifth Floor
100Providing and applying gypsum plaster (with Gypsum material of Gypsum India / Mega Sign or equivalent make) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface (Excluding rough cast plaster) in all position including preparing and Finishing the surface scaffolding etc.complete.
101(A) Ground Floor
102(B) First Floor
103(C) Second Floor
104(D) Third Floor
105(E) Fourth Floor
106(F) Fifth Floor
107Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.
108(A) Ground Floor
109(B) First Floor
110(C) Second Floor
111(D) Third Floor
112(E) Fourth Floor
113(F) Fifth Floor
114Providing internal cement plaster 12 millimetre thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.
115(A) Ground Floor
116(B) First Floor
117(C) Second Floor
118(D) Third Floor
119(E) Fourth Floor
120(F) Fifth Floor
121Providing internal cement plaster 20 millimetre thick in two coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete.
122(A) Ground Floor
123(F) Fifth Floor
124Providing waterproof plaster in Water Closet and bath 20 millimetre thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 kilogram per bag of cement of approved make and manufacturer and curing (and filling joints of Nahani trap and any outlet by properly) etc. complete.
125(A) Ground Floor
126(B) First Floor
127(C) Second Floor
128(D) Third Floor
129(E) Fourth Floor
130(F) Fifth Floor
131Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 millimetre thick in cement mortar 1:4 using waterproofing compound at 1 kilogram per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 millimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.
132(A) Ground Floor
133(B) First Floor
134(C) Second Floor
135(D) Third Floor
136(E) Fourth Floor
137(F) Fifth Floor
138Providing and applying Texture plaster with finishing with Purlina / Rustic texture material ( with texture material of Asian / Renava / Nitco / Temtex or equivalent company make ) in 3 to 4 millimeter thickness on previously finished plastered surface including Plaster Groove 6 millimeter thickness or Tape Grooves 35 to 45 millimeter thickness or as required, in all position including preparing the surface scaffolding etc.complete.
139(A) Ground Floor
140(B) First Floor
141(C) Second Floor
142(D) Third Floor
143(E) Fourth Floor
144(F) Fifth Floor
145Providing fine cement finish 1.5 millimetre thick over green plaster surface including scaffolding curing etc. complete.
146(A) Ground Floor
147(F) Fifth Floor
148Providing patti/ band 150 millimetre wide on plastered surface 12 millimetre to 15 millimetre thick in Cement Mortor 1:3 line and level including neat finishing scaffolding curing etc. complete.
149(B) First Floor
150(D) Third Floor
151(F) Fifth Floor
152Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of Rrinforced Cement Concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete / Burnt Brick masonry and or tying by binding wire etc. complete.
153Labour charges for providing groove in external plaster having width and spaced as directed by engineer incharge etc. complete.
154(A) Ground Floor
155(B) First Floor
156(C) Second Floor
157(D) Third Floor
158(E) Fourth Floor
159(F) Fifth Floor
160Stamp Concrete of 100 Millimeter Thickness - Providing and Laying in-situ M30 Grade unreinforced plain cement stamp concrete of 100 Millimeter thickness pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate (natural sand / Vertical Shaft Impactor grade finely washed crushed sand) Confirming to IS 383, as per mixed in a batching and mixing plant / non tilting mixer and weigh batcher as per approved mix design, admixtures, transporting to site in nagpur city with lead upto 20KM (on Inner Ring Road from Avasti nagar to wadi), spreading, laying with approved make pover, compacted and finished in a continous operation, finishing to lines and grades Also Providing, Placing and applying stamp powder which is light fast UV resistant pigment with appropriate chemical compounds of desired colour on base concrete after excess bleed water has evaporated using dry shake method @5 Kilogram per Squre Meter Including texturing, and covering with plastic sheet (min 200 micron thickness) and also applying two coats of UV-stable,30 % solids clear sealer @ 150 to 250 gms per Squre Meter using surface roller and protecting from falling dust,dirt and curring by curring compound / by providing cement vata in cement Mortor 1 :8 @ 0.6 Meter x 0. 6 Meter center to center, admeasuring 80 Millimeter at bottom and 40 Millimeter at top with depth of 75 Millimeter and maintaining the same throughout curing period by any other method approved by Engineer-incharge or Landscape architect etc. complete. (prior approval of superinteding Engineer will be necessary )
161Providing and laying vitrified matt fininsh tiles having size 590 millimetre to 605 millimetre x to 605 millimetre of 8 to 10 millimetre thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. a) Flooring
162(A) Ground Floor
163(B) First Floor
164(C) Second Floor
165(D) Third Floor
166(E) Fourth Floor
167(F) Fifth Floor
168Providing and laying vitrified rustic matt stone finish tiles having size 590 millimetre to 605 millimetre x 590 millimetre to 605 millimetre of 8 to 10 millimetre thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid ?on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. a) Flooring
169(A) Ground Floor
170(B) First Floor
171(C) Second Floor
172(D) Third Floor
173(E) Fourth Floor
174(F) Fifth Floor
175Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 millimetre to 20 millimetre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement Mortor 1:3 curing and cleaning etc. complete.
176(A) Ground Floor
177Providing and laying in position flooring / Skirting / Dado of Italian Marble of approved shade and size 18 millimetre to 20 millimetre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement Mortar 1:3 curing and cleaning etc. complete.
178(A) Ground Floor
179Providing and laying vitrified mirror / glossy finish tiles having size 600 millimetre X 1200 millimetre of 10 millimetre thickness and confirming to Indian Standard 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete.
180(A) Ground Floor
181(B) First Floor
182(C) Second Floor
183(D) Third Floor
184(E) Fourth Floor
185(F) Fifth Floor
186Providing and laying vitrified mirror / glossy finish tiles having size 590 millimetre to 605 millimetre x 590 millimetre to 605 millimetre of 8 to 10 millimetre thickness and confirming to Indian Standard 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete.
187(A) Ground Floor
188(B) First Floor
189(C) Second Floor
190(D) Third Floor
191(E) Fourth Floor
192(F) Fifth Floor
193Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 millimetre thick for door frame/ dado/ window boxing etc. on Cement Mortor 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete.
194(A) Ground Floor
195(B) First Floor
196(C) Second Floor
197(D) Third Floor
198(E) Fourth Floor
199(F) Fifth Floor
200Providing and fixing machine cut machine polished 18 millimetre to 20 millimetre thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.
201(A) Ground Floor
202(B) First Floor
203(C) Second Floor
204(D) Third Floor
205(E) Fourth Floor
206(F) Fifth Floor
207Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete.
208(A) Ground Floor
209(B) First Floor
210(C) Second Floor
211(D) Third Floor
212(E) Fourth Floor
213(F) Fifth Floor
214Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.
215(A) Ground Floor
216(B) First Floor
217(C) Second Floor
218(D) Third Floor
219(E) Fourth Floor
220(F) Fifth Floor
221Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface, (excluding the primer coat)etc. complete.
222(A) Ground Floor
223(B) First Floor
224(C) Second Floor
225(D) Third Floor
226(E) Fourth Floor
227(F) Fifth Floor
228Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 kilogram per 15 Litre). plaster crack should be filled by Acrylic base Crack seal / Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist.
229(A) Ground Floor
230(B) First Floor
231(C) Second Floor
232(D) Third Floor
233(E) Fourth Floor
234(F) Fifth Floor
235Providing and applying two coats of textured synthetic paint of approved shade and quality and one coat of primer before applying textured paint including scaffolding if necessary preparing surface by thoroughly cleaning oil, grease, dirt and other materials as required, etc. complete.
236(A) Ground Floor
237(B) First Floor
238(C) Second Floor
239(D) Third Floor
240(E) Fourth Floor
241(F) Fifth Floor
242Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300 millimetre X 40 millimetre X 5 millimetre with oil painting, etc. complete
243(A) Ground Floor
244(B) First Floor
245(C) Second Floor
246(D) Third Floor
247(E) Fourth Floor
248Providing and fixing M-40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to Indian Standard 6524-1983 having 6 millimetre diametres bars 3 Numbers And stirrups @ 250 millimetre centre to centre and fixing in wall with 6 Numbers of hold fast of 12 millimetre diametre bars 500 millimetre long including primer and oil painting etc, complete) frame size 60 millimetre x 100 millimetre.
249(D) Third Floor
250(F) Fifth Floor
251Providing and fixing the Country cut teak wood second class fully glazed openable fanlight rectangular in shape as per detailed drawing excluding the frame, stainless steel fixtures and fastenings and finishing the wood work with 3 coats of oil painting.
252(A) Ground Floor
253(B) First Floor
254(C) Second Floor
255(D) Third Floor
256(E) Fourth Floor
257(F) Fifth Floor
258Providing and fixing solid core flush door shutter in double leaf 32 millimetre thick decorative type of exterior grade as per detailed drawings approved face veneers 3 millimetre thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete.
259(B) First Floor
260(C) Second Floor
261(D) Third Floor
262(E) Fourth Floor
263Providing and fixing solid core flush door shutter in single leaf 32 millimetre thick decorative type of exterior grade as per detailed drawings approved face veneers 3 millimetre thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete.
264(A) Ground Floor
265(B) First Floor
266(C) Second Floor
267(D) Third Floor
268(E) Fourth Floor
269(F) Fifth Floor
270Providing and fixing Indian Standard Institute marked double swing flush door shutters conforming to Indian Standard :2202 (Part I) Non-decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 millimetre thick including Indian Standard Institute marked Stainless Steel L- hinges with necessary screws Fittings and Fixtures per leaf Stainless steel kick plates on both sides of the door of 300 millimetre height Heavy Duty satin finish butt Stainless Steel Hinges (100 millimetre x 75 millimetre x 3 millimetre in size) - 4 numbers Stailess Steel finished lever handle with mortise lock- 1 no. Floor spring- 1 Number 100 millimetre x 100 millimetre safety glass at the specified location
271(B) First Floor
272(C) Second Floor
273(D) Third Floor
274(E) Fourth Floor
275(E) Fourth Floor
276Providing and Fixing 30 millimetre thick \\" FACTORY MADE BOTH SIDE PRELAMINATED SOLID PANEL Poly Vinyl Chloride DOOR SHUTTER manufactured by M/S RAJSHRI equivalent consisting of frame made out of Mild Steel tubes of 19 guage thickness and, size 19 x 19 millimetre for styles and 15 X l5 millimetre for the top and bottom rails, Mild Steel frame shall have a coat of metel primer of approved make and manufacture. Mild Steel frame shall be covered with heat mouled Poly Vinyl Chloride 'C ' channel made from 5 millimetre (+/- 0.25) thick prelaminated sheet of density 600 kilogram per cubicmetre, of size 30 millimetre thickness 70 millimetre width out of which 50 millimetre shall be flat and 20 millimetre shall be tapered in 45 angle on either side forming stiles; and 5 millimetre thick, 95 millimetre wide Poly Vinyl Chloride sheet out of which 75 millimetre shall be fait and 20 millimetre shall be tapered in 45 on the inner side to form top and bottom rail and 115 millimetre wide Poly Vinyl Chloride sheet out of which 75 millimetre shall be fait and 20 millimetre shall be tapered on both sides to form lock rail. Top, bottom and lock rail shall be provided either side of the panel. An additional 5 millimetre (+/- 0.25) thick Poly Vinyl Chloride strip of 20 millimetre width is to be stuck on the bottom side of the 'c' channel prelaminated paneling of 5 millimetre (+/- 0.25) thick Poly Vinyl Chloride sheet to be fitted inside the Mild Steel frame welded / sealed to the styles and rails with 5 millimetre (+/- 0.25) x 30 mm Poly Vinyl Chloride sheet beading on either side and joined together with solvent cement adhesive etc, 10 millimetre thickness (5 millimetre (+/-0.25) x 2 Numbers ) 20 millimetre wide cross Poly Vinyl Chloride sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 Numbers Mild Steel powder coated but hinges of size 100 millimetre x 25 millimetre x 2 millimetre using 32 millimetre long steel screws drilled suitable to pass through both the walls of the Mild Steel tube. Other hardwares should be fixed with 19 x 6 millimetre size steel screws including fixture fasting. Complete as per direction of engineer -in -charge .
277(A) Ground Floor
278(B) First Floor
279(C) Second Floor
280(D) Third Floor
281(E) Fourth Floor
282(F) Fifth Floor
283Providing and fixing of factory made Unplasticized Polyvinyl Chloride Sliding window (White Colour) complete, comprising Unplasticized Polyvinyl Chloride multi-chambered frame having in-built Unplasticized Polyvinyl Chloride roller track on top and Unplasticized Polyvinyl Chloride sash with wall thickness of 2.3mm (+-0.2 Millimeter ), duly reinforced with G.I. section 1.5 Millimeter wherever required. Unplasticized Polyvinyl Chloride window & door profile shall be made in India & shall conform to British Standard EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm25 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm26 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame British Standard : 476 - Part 7 Classification 18 Ignitability Evaluation British Standard : 476 - Part 5 'P' Not easily ignitable9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa11 Tensile Strength EN ISO 527 Shall not be < 30 MPaAll corners of frame and sash will be fusion welded. After placing 5 Millimeter Float Annealed glass in the sash, Unplasticized Polyvinyl Chloride glazing bead, interlock, EPDM / TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window / Door will be fixed to the wall with 100 Millimeter long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. Unplasticized Polyvinyl Chloride Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use.b) 3 Track 3 / 6 Sash (Big Series) window frame of size 122 x 54 Millimeter & Sash of size 64 x 47 Millimeter
284(A) Ground Floor
285(B) First Floor
286(C) Second Floor
287(D) Third Floor
288(E) Fourth Floor
289(F) Fifth Floor
290Providing and fixing Strong Room Door of specified size of GODREJ Make with Grill Gate, Godrej Air Ventilator (Hevy Duty ), Godrej Air Exhust Fan and Godrej V-Cage ( Fan Cover ) incuding conveying, loading, unloading etc. complete.
291(B) First Floor
292(C) Second Floor
293(D) Third Floor
294(E) Fourth Floor
295Providing and fixing factory made Unplasticized Polyvinyl Chloride twin sash casement glazed window (White Colour) comprising of two shutters, one outward opening having glass and one inward opening having SS Mesh and integrated grill provision between two shutters. Unplasticized Polyvinyl Chloride multi-chambered frame, sash, bugmesh sash and mullion (where ever required) extruded profiles with wall thickness of 2.3 Millimeter (+-0.2 Millimeter ) duly reinforced with Galvnised Iron section 1.50 wherever required. Unplasticized Polyvinyl Chloride window & door profile shall be made in India & shall conform to British Standard EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m2 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/ Millimeter 25 Mean Breaking Stress for welded corner (a) For the tensile bending test EN – 514 Shall not be < 25 N/ Millimeter 2 (b) For the compression bending test Shall not be < 30N/ 2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 % 7 Surface Spread of flame British Standard : 476 - Part 7 Classification 1 8 Ignitability Evaluation British Standard : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 Megapascal 10 Shear Modulus ASTM D 732 Shall not be < 220 Megapascal 11 Tensile Strength EN ISO 527 Shall not be < 30 Megapascal All corners of frame and sash will be fusion welded. Mullion shall be welded / screwed. EPDM / TPE Gasket shall be provided in all frame, sash & mullion, wherever necessary.Thereafter, 5 Millimeter Float Annealed glass shall be provided in the sash with the help of Unplasticized Polyvinyl Chloride glazing bead and hardware, i.e., friction hinge & single point handle (in window) & 3D Hinges & Multipoint Lock (in door) shall be provided. Window / Door shall be fixed to the wall with 100 Millimeter long and 8 Millimeter. dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. Unplasticized Polyvinyl Chloride Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use. a)Twin Sash Casement Window frame of size 122 x 62 Millimeter sash 67 x 78 Millimeter & bug-mesh sash of 42 x 84 Millimeter.
296(A) Ground Floor
297(B) First Floor
298(C) Second Floor
299(D) Third Floor
300(E) Fourth Floor
301(F) Fifth Floor
302Providing and fixing of factory made Unplasticized Polyvinyl Chloride. Louver window (White Colour) comprising of Unplasticized Polyvinyl Chloride. multi-chambered with wall thickness of 2.3 Millimeter (+-0.2 mm ), duly reinforced with 1.5 Millimeter thick Galvnised Iron. Section. Unplasticized Polyvinyl Chloride. window & door profile shall be made in India & shall conform to British Standard EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specifie Parameter1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/ mm 25 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/ mm 2(b) For the compression bending test Shall not be < 30N/mm26 Heat Reversion Test Indian Standard :4985-2000 Shall not be > 2.0 %7 Surface Spread of flame British Standard : 476 - Part 7 Classification 18 Ignitability Evaluation British Standard : 476 - Part 5 'P' Not easily ignitable9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa11 Tensile Strength EN ISO 527 Shall not be < 30 MPa. All corners of frame shall be fusion welded. Both vertical sides of the frame, adjustable louver mechanism having one lever or fixed louver bracket shall be fitted with the of 4 Millimeter Frosted Annealed glass. Window will be fixed to the wall with 100 Millimeter long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. Unplasticized Polyvinyl Chloride. Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration,wrapping and rotting under general use.a.Louver Window (Big Series) frame of size 67 x 62 Millimeter & Mullion (if required) of size 67 x 78 Millimeter
303(A) Ground Floor
304(B) First Floor
305(C) Second Floor
306(D) Third Floor
307(E) Fourth Floor
308(F) Fifth Floor
309Providing and fixing mild steel grill work for windows, ventilators etc. 20 kilogram per squaremetre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.
310(A) Ground Floor
311(B) First Floor
312(C) Second Floor
313(D) Third Floor
314(E) Fourth Floor
315(F) Fifth Floor
316Providing and fixing in position Gypsum board false ceiling with 12.5 millimeter thick Gypsum boards, screwed / fixed to the under structure of suspended Galvanised Iron Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 millimeter maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.
317(F) Fifth Floor
318Providing and fixing Modular false ceiling of 600 x 600 millimetre center to center and 13 millimetre thick square mineral fiber board to be fixed on frame work of alluminium sections for suspended false ceiling consisting of alluminium T 2”x1 ½” (50 millimetre x 40 millimetre) weighing 0.39 kilogram per Metre at 60 centimetre center center and fixed with ½” x ½” (15 x 15 millimetre) flanges weighing 0.19 kilogram per Metre suspended on 6 millimetre diametre mild steel rod weighing 0.22 kilogram per metre, fixed on wall and beams including rounding of the edges with alluinium T of 2” x 1 ½” (50 millimetre x 40 millimetre) weighing 0.39 kilogram per Metre etc. (all alluminium sections shall be anodized) including all labour, material, lifts etc. complete.
319(A) Ground Floor
320(B) First Floor
321(C) Second Floor
322(D) Third Floor
323(E) Fourth Floor
324(F) Fifth Floor
325Providing and Fixing of Mineral Fibre Acoustical Suspended Ceiling System with ultima (Bevelled Tegular) Edge Tiles of size 15 millimetre Exposed GRID. The tiles should have Humidity Resistance (RH) of 99 percentage, NRC 0.7, Light Reflectance 85 percentage, Thermal Conductivity k = 0.052 - 0.057 watt per metre K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 20 millimetre , suitable for Green Building application, with Recycled content of 32 percentage. The tile shall be laid on precoated Galvanized Iron channel on XL2 Clip having a web height of 32 millimetre with 15 millimetre wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 millimetre and 600 millimetre Cross Tees with a web height of 32 millimetre and a load carrying capacity of 7.7 Kgs/M2 and minimum pull out strength of 100 Killograms. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system. The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etc. complete.
326(B) First Floor
327(C) Second Floor
328(D) Third Floor
329(E) Fourth Floor
330Providing and fixing Glass Fiber Reinforced Concrete (GFRC) panels of 40 mm thickness, manufactured with cement, alkali-resistant glass fibres (3-5%), fine aggregates, polymer modifiers and approved additives, including casting, curing, finishing, transportation, erection and fixing complete as per Engineer-in-Charge.
331(A) Ground Floor
332(B) First Floor
333(C) Second Floor
334(D) Third Floor
335(E) Fourth Floor
336Kitchen Trolley Providing and Fixing stainless steel kitchen trolley of overall 26 \\" height and 22\\" depth,supported on aluminium pipes ,trolley basket made out of 5 millimetre stainless steel rod fitted on telescopic channel of size 1.5 \\" x 20 \\" x 22 \\" on both sides of trolley of 12 \\" or above size, panel having 40 kg load bearing capacity of trolley made out of 20 millimetre PUC coated plywood and colour combination as directed by E-I-C.Inner side of panel covered by white mica ,100 millimetre s.s. decorative handle.(The width and height of individual compartments shall be kept as directed by Engineer-in-charge)
337(B) First Floor
338(F) Fifth Floor
339Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 millimetre x 450 millimetre size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 millimetre thick supports with kadappah top 35 to 40 millimetre thick and polished granite 16 to 20 millimetre top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimetre height and top granite of 75 x 40 centimetre including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 Millimeter x 0.60 Millimeter and height is 0.75 Millimeter )
340(B) First Floor
341(F) Fifth Floor
342Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 millimetre diametre and vertical pipe of 38 millimetre diametre at 0.60 metre centre to centre or as required and horizontal pipes of 25 millimetre diametre in three rows, all pipes of 2 millimetre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 millimetre diametre above newel post of 75 millimetre diameter etc. complete (Prior approval of sample and brand by Ex. Engineer is necessary before use)
343(A) Ground Floor
344(B) First Floor
345(C) Second Floor
346(D) Third Floor
347(E) Fourth Floor
348(F) Fifth Floor
349Providing and fixing 900 millimetre high Stainless Steel 304 Grade Stainless steel railing with 40 millimetre diameter and 1.5 millimetre thick at top, 40 millimetre diameter and 1.5 millimetre thick vertical supports spaced at 1.5 metre center to center and 8 millimetre thick toughened glass including fabricating ,fixtures, errecting, necessary welding , grinding, finishing, buffing to stainless steel pipe etc. complete.
350(A) Ground Floor
351(B) First Floor
352(C) Second Floor
353(D) Third Floor
354(E) Fourth Floor
355(F) Fifth Floor
356Providing and fixing in position aluminium partly openable and partly fixed window of any size as per detailed drawing and as directed by Engineerincharge with all necessary alluminium sections including necessary fixtures and fastening with 6mm Toughned glass etc. complete. b) With powder coating Note While arriving at the rate of item of item weight at 6.90 kg/Sqm is considered.
357Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 sqm /kg with two coat using Dr. Fixit or alike of chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete.
358(B) First Floor
359(C) Second Floor
360(D) Third Floor
361Supply and Installation of translucent roof with DPI Flux standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded Ultra Voilet protected multicell panels incorporated into a complete system. Co-extruded Ultra Voilet protected polycarbonate panel system of minimum 12 millimetre thick of 900 millimetre (min.) width with angular daylighting concept. Panels shall have minimum six layers with truss bridge design for higher flexibility and strength. Panels with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on Mild Steel structure (will be paid Separately) with 3 One Numbers self-drilling screws and trapezoid Stainless Steel fasteners holding the base of the standing seam offering best stability having a pull-out load of minimum 7000 Newton (7 Kilo Newton) tested as per ISO 6892:1998 and Indian Standard 1608: 2005, as per design requirement. Panels must satisfy Dart drop impact test as per Indian Standard 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to Ultra Voilet for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to Ultra Voilet for 500 Hours as per ASTM G 155. U value shall not be more than 1.6 W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over Mild Steel structural steel/Mild Steel purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing & direction of the engineering in charge. Colour: As per Approval. Approved Make: FLUX by DPI Daylighting or approved equivalent The 12 millimetre thick panels shall be used for a roofing height of upto 15 metres
362(F) Fifth Floor
363Waterproofing Treatment to new terrace by using Polymeric Cementitious Membrane as approved by Engineer in charge, followed by 112mm thick brick bat coba covered with 20 mm mortar finish. If there are cracks on the bare slab, open the crack in V Groove and fill it with ready to use repair polymer modified mortar based on special cements, aldehyde based polymers with thixotropy modifying agents. If there are lots of honeycombs and identified bad patches of concrete the same should be grouted as per the instructions of site incharge. (The grouting shall be paid separately). Clean the entire surface thoroughly and over this prepared surface, apply three coats of polymeric Cementitious waterproofing coating having a non-toxic, 2-(methoxycarbonyl)-1-propene-Butyl-2 propenoate (MPBP) based polymeric waterproofing solution as approved by Engineer in charge. Provide and lay 112 mm average thicknes of brick bat coba in cement mortar 1:5 over 12mm thick CM 1:3 bedding with one pouch of 330 grams of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents as approved by Engineer in charge per 50 Kg bag of cement and finishing with 20 mm thick cement plaster in cement mortar 1:3 by mixing one 330 grams pouch of above admixture per 50 Kg bag of cement, including all lead, lifts and laid to proper slope to drain off water entirely preparing bell mouth including watta, beveled or champhered portion at the junction of parapet and work up to a height of 300 mm or as directed and including finishing the top layer of waterproofing treatement with false marking of 30 cm x 30 cm or as directed, curing and covering the whole treatment. MPBP Polymeric Waterproofing Coating for Concrete and Masonry should have following minimum properties: (1) Elongation % (ASTM D412-2016): @ 100% (2) Tensile Strength N/mm2 (ASTM D412-2016): 3.3 (3)
364(F) Fifth Floor
365Providing and laying damp proof course 50 millimetre thick in M20 cement concrete layer and bitumen / using cement with waterproofing compound curing, formwork etc. complete.
366Providing waterproofing in Water Closet and bath including brick bat coba in all position including providing and laying 12 millimetre bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1 kilogram per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 kilogram per bag of cement grouting and finishing the top layer with 20 millimetre thick brick bedding in cm mortor 1:3 with waterproofing compound 1 kilogram per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete.
367(A) Ground Floor
368(B) First Floor
369(C) Second Floor
370(D) Third Floor
371(E) Fourth Floor
372(F) Fifth Floor
373Providing, laying and fixing Poly Vinyl Chloride pipe of 40 millimetre diametre with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Work Department chowky or as directed etc. complete.
374Providing, laying and fixing Poly Vinyl Chloride pipe of 50 millimetre diametre with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Work Department chowky or as directed etc. complete.
375Providing and fixing 75 Millimeter dia stabiliser pipe/ Poly Vinyl Chloride. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete
376Providing and fixing 100 Millimeter dia stabiliser pipe/ Poly Vinyl Chloride soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.
377Providing and laying in trenches 40millimetre diametre Chlorinated Poly Venyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Work Department chowky or as directed etc. complete.
378Providing and fixing on walls/ceiling/floor 15 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Work Department chowky or as directed etc. complete.
379(A) Ground Floor
380(B) First Floor
381(C) Second Floor
382(D) Third Floor
383(E) Fourth Floor
384(F) Fifth Floor
385Providing and fixing on walls/ceiling/floor 20 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Work Department chowky or as directed etc. complete.
386(A) Ground Floor
387(B) First Floor
388(C) Second Floor
389(D) Third Floor
390(E) Fourth Floor
391(F) Fifth Floor
392Providing and fixing on walls/ceiling/floor 25 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Work Department chowky or as directed etc. complete.
393(A) Ground Floor
394(B) First Floor
395(C) Second Floor
396(D) Third Floor
397(E) Fourth Floor
398(F) Fifth Floor
399Providing and fixing on walls/ceiling/floor 32 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Work Department chowky or as directed etc. complete.
400(A) Ground Floor
401(B) First Floor
402(C) Second Floor
403(D) Third Floor
404(E) Fourth Floor
405(F) Fifth Floor
406Providing and fixing on walls/ceiling/floor 40 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Work Department chowky or as directed etc. complete.
407(A) Ground Floor
408(B) First Floor
409(C) Second Floor
410(D) Third Floor
411(E) Fourth Floor
412(F) Fifth Floor
413Providing and fixing on walls/ceiling/floor 50 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Work Department chowky or as directed etc. complete.
414(A) Ground Floor
415(B) First Floor
416(C) Second Floor
417(D) Third Floor
418(E) Fourth Floor
419(F) Fifth Floor
420Providing and fixing on walls/ceiling/floor 20 Millimeter dia. Unplasticized Polyvinyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Work Department chowky or as directed etc. complete.
421(A) Ground Floor
422(B) First Floor
423(C) Second Floor
424(D) Third Floor
425(E) Fourth Floor
426(F) Fifth Floor
427Providing and fixing on walls/ ceiling/ floor 25 Millimeter dia. Unplasticized Polyvinyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Work Department chowky or as directed etc. complete.
428(A) Ground Floor
429(B) First Floor
430(C) Second Floor
431(D) Third Floor
432(E) Fourth Floor
433(F) Fifth Floor
434Providing and fixing on walls/ ceiling/ floor 32 Millimeter dia. Unplasticized Polyvinyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Work Department chowky or as directed etc. complete.
435(A) Ground Floor
436(B) First Floor
437(C) Second Floor
438(D) Third Floor
439(E) Fourth Floor
440(F) Fifth Floor
441Providing and fixing on walls /ceiling/ floor 40 Millimeter dia. Unplasticized Polyvinyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Work Department chowky or as directed etc. complete.
442(A) Ground Floor
443(B) First Floor
444(C) Second Floor
445(D) Third Floor
446(E) Fourth Floor
447(F) Fifth Floor
448Providing and fixing on walls/ ceiling/ floor 50 mm dia. Unplasticized Polyvinyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete.
449(A) Ground Floor
450(B) First Floor
451(C) Second Floor
452(D) Third Floor
453(E) Fourth Floor
454(F) Fifth Floor
455Providing and fixing on walls/ ceiling/ floors, 80 millimetre diametreheavy grade having embossed as Indian Standard Instiute Mark galvanised iron pipes weight of 10.15 Kilogram per meter with necessary fittings. and remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
456Providing and fixing on walls/ ceiling/ floors, 100 millimetre diametreheavy grade having embossed as Indian Standard Institute Mark galvanised iron pipes weight of 14.74 Kilogram per meter with necessary fittings. and remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in Public Work Departmen chowky or as directed etc. complete.
457Providing and making Indian Standard Institute Mark ferrule connection of 32 millimetre diametre to water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete.
458Providing, laying and fixing Poly Vinyl Chloride pipe of 110 millimetre diametre with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Work Department chowky or as directed etc. complete.
459(A) Ground Floor
460(B) First Floor
461(C) Second Floor
462(D) Third Floor
463(E) Fourth Floor
464(F) Fifth Floor
465Providing and fixing Poly Vinyl Chloride Rain water pipes of 160 millimetre outer diameter and having wall thickness of 2.2 to 2.7 millimetre confirming to Indian Standard 13592-1992 including proper rainwater receiving recess with Poly Vinyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 millimetre to 40 millimetre from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on CEment Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the Poly Vinyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. (The contractor shall give 3 yrs guarantee bond for payment)
466(A) Ground Floor
467(B) First Floor
468(C) Second Floor
469(D) Third Floor
470(E) Fourth Floor
471(F) Fifth Floor
472Providing, laying and fixing Poly Vinyl Chloride pipe of 75 millimetre diametre with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Work Department chowky or as directed etc. complete.
473(A) Ground Floor
474(B) First Floor
475(C) Second Floor
476(D) Third Floor
477(E) Fourth Floor
478(F) Fifth Floor
479Providing and fixing Chromium Plated a 2-Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge.
480(A) Ground Floor
481(B) First Floor
482(C) Second Floor
483(D) Third Floor
484(E) Fourth Floor
485(F) Fifth Floor
486Providing and fixing Chromium Plated BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge.
487(A) Ground Floor
488(B) First Floor
489(C) Second Floor
490(D) Third Floor
491(E) Fourth Floor
492(F) Fifth Floor
493Providing and fixing 25millimetre diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangement and lock. [Without chamber].
494Providing and fixing orissa type colour glazed earthenware 625 x 450 Milimeter Water Closed pan including trap, Cast Iron soil and vent pipe upto the out side face of wall including 100 mm. dia. Cast Iron plug bend, 15 Millimeter thick 10 litre Poly Vinyl Chloride flushing cistern with all necessary pipe connection etc. complete.
495(A) Ground Floor
496(B) First Floor
497(C) Second Floor
498(D) Third Floor
499(E) Fourth Floor
500Providing and fixing white european type wall-hung pan, of size 350 millimeter X 355 millimetre X 570 millimetre concealed flush tank with floor-mounting frame installing kit and drain pipe connection set for wall hung Water Closet, with approved make square control plates including soil pipe, vent pipe upto the outside face of wall, 100 millimetre dia Cast Iron plug bend inlet pipe all fittings,cutting and making good walls, floors etc. complete.
501(A) Ground Floor
502(B) First Floor
503(C) Second Floor
504(D) Third Floor
505(E) Fourth Floor
506(F) Fifth Floor
507Providing and fixing White Glazed Earthenware full stall type Urinal with Poly Vinyl Choride flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 millimetre diametre Poly Vinyl Choride flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connection up to the outside face of the wall
508(A) Ground Floor
509(B) First Floor
510(C) Second Floor
511(D) Third Floor
512(E) Fourth Floor
513Providing and fixing machine cut mirror polished 18 millimetre to 20 millimetre thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with rounding the edges etc. complete . Both side polish
514(A) Ground Floor
515(B) First Floor
516(C) Second Floor
517(D) Third Floor
518(E) Fourth Floor
519Providing and Fixing toilet set for differently Abled persons consist of Floor Mounted white vitreous china water Closet including 6 litre capacity white vitreous china flushing Cistern with raised soft-push button, white vitreous china wash basin of size 46 x 36 centimetre and one no Stainless Steel 304 hinged rail 76 centimetre and three no Stainless Steel 304 of (Grab Bar) 60 centimetre all including cutting and making good the walls and floors wherever required ,seat cover, cistern and wash basin fittings,nuts, bolts and gasket etc complete of make Hindware(Matrix series 70002)/ Cera or equivalent as per the direction of Engineer-In-charge.
520(A) Ground Floor
521(B) First Floor
522(C) Second Floor
523(D) Third Floor
524(E) Fourth Floor
525Providing and fixing 10 centimetre Poly Venyl Chloride nahani trap with grating etc. complete.
526(A) Ground Floor
527(B) First Floor
528(C) Second Floor
529(D) Third Floor
530(E) Fourth Floor
531(F) Fifth Floor
532Providing and fixing chromium plated towel rod 16 millimetre diametre and 75 centimetre in length including all accessories complete.
533(A) Ground Floor
534(B) First Floor
535(C) Second Floor
536(D) Third Floor
537(E) Fourth Floor
538(F) Fifth Floor
539Providing and fixing 450 millimetre X 550 millimetre size superior type Belgium mirror with 16 milimetre diametre nickel plated towel rod etc. complete.
540(A) Ground Floor
541(B) First Floor
542(C) Second Floor
543(D) Third Floor
544(E) Fourth Floor
545(F) Fifth Floor
546Providing and constructing Ductile Iron circular manhole 45 centimetre diametre At top 90 centimetre at bottom up to 1.80 meter to 2.70 meter depth including excavation, laying 1:4:8 cement concrete bedding 15 centimetre thick burnt brick mansonry with 1:1 cement mortar plaster 25 millimetre thick inside and outside 20 millimetre (1:3) ductile iron heavy type cover with ring 125 killogram in weight. High strength. More life and Durability, Good Antiskid Grip, Suitable to heavy theatric loading, Light weight casting after cost benefits for Transportation Refilling etc. as per requirement. with prior approval of concerned Superitending Engineer.
547Providing and fixing 15 centimeter x 10 centimeter salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.
548Providing and constructing Brick Masonry Inspection Chamber 60 Centimeter x 45 Centimeter With Rainforced Cement Concrete. raft in B.C. soil area including cost of reinforcement, 1:2:4 cement concrete channels half round Glaged Stoneware pipes, Brick Masonry, plastering from inside and airtight 75 Millimeter thick Rainforced Cement Concrete. cover medium duty 100 Kilogram etc. complete.
549Providing and constructing Brick Masonry Inspection Chamber 90 Centimeter x 45 Centimeter With Rainforced Cement Concrete raft in B.C. soil area including cost of reinforcement, 1:2:4 cement concrete channels half round Glaged Stoneware pipes, Brick Masonry, plastering from inside and airtight with 75 Millimeter thick Rainforced Cement Concrete cover medium duty 140 kg etc. complete.
550Providing and fixing 40 millimetre dia Ball cock medium type with Poly Vinyl Chloride float including sockets and necessary fittings and tested as per municipal requirements etc. complete.
551(F) Fifth Floor
552Providing and fixing High Density Polyetheylene container Sintex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres
553(F) Fifth Floor
554Providing soak pit of size 120 centimetre X 120 centimetre X 120 centimetre including excavating and filling with brick-bats.
555Providing and fixing Chromium Plated wall mixer with provision for overhead shower with 115 millimetre long bend pipe and wall flange of approved make including necessary sockets/union nut etc. complete.
556(A) Ground Floor
557(B) First Floor
558(C) Second Floor
559(D) Third Floor
560(E) Fourth Floor
561(F) Fifth Floor
562Providing and fixing Table top white wash basin of size 120x635x405 Millimeter rubber plugs and brass chain, with pillar cock, Chrome-Plated.Angular stop cock long thread, continental including Stainless Steel bottle trap of approved make having necessary pipe connection up to theoutside face of the wall.etc complete as directed by Engineer in charge.
563(A) Ground Floor
564(B) First Floor
565(C) Second Floor
566(D) Third Floor
567(E) Fourth Floor
568(F) Fifth Floor
569Providing and fixing heavy duty inter locking concrete RUBBER MOULD GLOSSY PAVING BLOCKS of 60 millimeter thickness of having a strength of 400 Kilogram per Squaremetre of approved quality and shape on a bed of crushed sand of 25 to 30 millimeter thick including striking joints and cleaning etc. complete, (using 100 percentage crushed sand)
570Providing , laying and fixing ,jointing Supreme Eco- drain 160 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees , coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete.
571Providing , laying and fixing ,jointing Supreme Eco- drain 200 mm SN 4 Nu- Drain Unplasticized Polyvinyl Chloride pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per Indian Standard 15328 with fittings such a bends, tees tees, coupler etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete.
572Providing and laying concrete pipes of Indian standard NP. class of 300 millimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
573Providing and fixing in position Unplasticized Poly Vinol Chloride ultra violet stabilized 110 millimetre outer diameter cowl dome confirming to Indian Standard-4985 including making joints with solvent cement etc. complete
574(F) Fifth Floor
575Providing and fixing lightening conductor system comprising of erecting Air-Termination consisting of tubular copper rod of 25 millimeter dia. 1.2 millimeter thick with multiple points head 1.2 metre long ( Heavy Duty) welded or clamped to Galvanised Iron pipe pole B grade 50 millimeter diametre of requiired length with Mild Steel round bnase plate 25 centimetre diametre and 10 millimeter thick at bottom embeded in cement concrete 1:3:6 foundation of size 45 centimetre diametre x 45 centimetre Height and providing earthing with copper earth plate of size 60 x 60 x 0.3 centimetre with cadmium plated nut bolts to fix earthing strip burried in specially prepared earth pits 1.5 metre below ground level with 40 kilogram charcoal and salt with altemate layers of charcoal and salt and Galvanised Iron pipe 40 millimeter diametre 2 meter length burried in earth upto earthling plate remining portion above ground level for watering and refilling comcpete Note- Copper strip fropm lightening conductor is not considered in this item.
576Providing and fixing copper strip 25 millimeter wide and 3 millimeter thick for lightening conductor including fixing with screws required scaffolding etc.complete Note- Lightening conductor and earthing pits is not considered in this item
577Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20 metre X 0.90 metre size made out 18 gauge (1.25 metre) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on Mild Steel angle of size 35 x 35 x 3 millimetre frame with properly cross braced Mild Steel angles of size 35 millimetre x 35 millimetre x 3 millimetre duly painted including Two Mild Steel angle iron posts of size 65 millimetre x 65 millimetre x 6 millimetre, 3.65 metre long painted with alternate black and white bands of 25 centimetre width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 centimetre x 60 centimetre x 75 centimetre including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge pec. No. As directed by Engineer in Charge
578Rain Water Harvesting - Shallow Percolation Pit providing, constructing 2.0 Meter deep shallow depth percolation pit comprising of 1.0 Meter dia pre-cast Rainforced Cement Concrete rings, 300 Millimeter thick side filling around outside of Rainforced Cement Concrete rings (annular space) with 40 Millimeter size boulders including filling of percolation pit up to 0.5 Meter depth (from bottom up) with 25-75 Millimeter clean washed gravels followed by 0.5 Meter depth of 10-25 Millimeter of clean washed stones followed by 0.5 Meter of washed river fine aggregate (natural sand/crushed sand Vertical Shaft Impactor grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand Vertical Shaft Impactor grade finely washed etc.) media layer including covering with Rainforced Cement Concrete slab, manhole frame & cover, Poly Vinyl Chloride rungs etc. including arrangement for inlet & outlet pipe, excavation & backfilling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge
579Conveying materials obtained from road cutting including all lifts, laying in layers of 20 centimetre to 30 centimetre breaking clods, dressing to the required lines, curves, grades and section, watering and compacting to not less than 97 percentage of standard Proctor density for a lead of over 50 metre to 300 metre inclusive from the site of excavation to the site of deposition as directed.
580Providing and fixing 45 centimetre wide mild steel ladder of 40millimetre x 6 millimetre mild steel flat stringers and steps of 18 millimetre diamtre mild steel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60 centimetre X 30 centimetre X 30 centimetre and painting the ladder complete. (Anti Corossive Paint)
581(F) Fifth Floor
582Making 150 millimetre diametre Bore in all types of Strata with head core including survey for fixing location of bore transporting of machinery and platform, providing laying fixing casing of 150 millimetre diametre Unplacticised Poly Vinyl Chloride Pipe (CS as per IS:12815) having outer diametre 165 and minimum thickness of 5.70 to 6.50 millimetre diametre along with grouting, checking capacity by flushing test etc. complete.
583Survey for Fixing Location
584Making Bore in all types of Strata
585Providing and Laying and fixing casing of 150 millimetre diametre Ultra Poly Vinyl Chloride pipe to withstand continous internal hydraulic pressure of 6 kilogram per square centimetre (Cross Section as per IS:12818-1992) having outer diametre 165.40 millimetre and minimum thickness 5.70 to 6.50 millimetre along with grouting.
586Checking Capacity by Flushing test
587Lady Justice Sculpture (Law & Judiciary Symbol) - FRPProviding, fabricating, supplying and installing Lady Justice Sculpture (Symbol of Law & Judiciary) of 1.80 m (approx. 6 ft) height made of Fibre Reinforced Plastic (FRP) including modelling, moulding, casting. finishing and fixing complete as per approved design and direction of Engineer-in-Charge.The work shall include artistic modelling of the Lady Justice figure (with balance scale and sword) using special Shadu clay to achieve proper proportions and detailing. After approval of the model, waste mould shall be prepared in Plaster of Paris (POP) reinforced with 2\\" x 2\\" wooden batten strips or bamboo supports for adequate strength during casting. The final casting shall be carried out in FRP (ISO grade) using mixture of resin, cobalt and hardener, reinforced with FRP mat in minimum two layers, maintaining uniform thickness of 5 mm to 10 mm for durability and structural stability.After casting, the surface shall be cleaned using nitric acid and water treatment to prepare the surface for finishing. The cleaned surface shall be provided with one coat of grey aster primer applied with air compressor spray machine.The sculpture shall then be painted with PU based decorative paint in minimum 2 to 3 coats, and the finished surface shall be protected withclear PU protective coating for long-term weather resistance.The item shall include transportation handling installation on
588Decorative Fountain with Lady Justice/Law Book Statue (FRP)Providing, fabricating, supplying and installing Decorative Fountain with central statue of Lady Justice (Law & Judiciary Symbol) or Law Book, complete in all respects including civil work, FRP sculpture, water circulation system, finishing and installation as per approd design and direction of the Engineer-in-Charge.The work shall include artistic modelling of Lady Justice figure (with balance scale and sword) or Law Book symbol using special Shadu clay for detailed sculptural form. After finalization of the model, a waste mould shall be prepared using Plaster of Paris (POP) reinforced with 2\\" 2\\" wooden batten strips or bamboo supports for structural stability during casting.The final casting of sculpture shall be done in FRP (ISO grade) using a mixture of resin, cobalt and hardener, reinforced with FRP mat in minimum two layers, maintaining uniform wall thickness of 5 mm to 10 mm. The cast surface shall be cleaned using nitric acid and water treatment to prepare it for finishing.After cleaning, the sculpture surface shall be provided with one coat of grey aster primer applied with air compressor spray machine, followed by 2-3 coats of PU based decorative paint. The final surface shall be protected with clear PU protective coating to ensure durability and weather resistance.The work shall also include construction of decorative fountain basin in
589Coper/ Brass Enameling
590Coper Repose / Brass Repose
591Portrait of Law Lady Oil on Canvas Reference Collection, Sketching & Composition, Layering & Detailing, Varnishing & Framing (5' x 3')
592Portrait of Law Lady Bronze Round Sculpture Armature of statue (main internal structure of statue) Clay Modelling work of Statue Modelling in shadu clay as per character and pose of statue) Plaster Mould (POP diy on Final Clay work of fiber casting) Fiber Casting (Casting in fiber glass ISO resin) Metal Casting (plaster piece mould, wax copy, wax copy finishing, core mould, core molding baking and final bronze metal casting)Metal Brazing and Finishing (finishing of statue) Oxidising (Chemical treatment for surface colour) Transportation (transportation material, metal casting process, and for final installation. (8' Heigth)
593Vinyl Print with Design Conceptual designing and research team Designing and Working Drawing Preparation HP High Quality Long Durability Print with Stander Media Qty. 4000 Sqr. Ft
594Vinyl Print with 3mm Sunboard with Design Conceptual designing and research team Designing and Working Drawing Preparation HP High Quality Long Durability Print with Stander Media
595Slab Moulding Applications (Decorative)Providing and fixing decorative slab moulding to RCC slab edges, beams or ceiling portions using cement mortar/FRP/POP moulded profiles of approved design and pattern, including preparation, fixing, finishing and painting complete as per approved drawings and direction of the Engineer-in-Charge. The work shall include surface preparation of the RCC slab edge, applying bonding agent where required and fixing pre-cast moulded profiles or in-situ mouiding using cement mortar mix (1:3)/POP/FRP decorative sections as per approved pattern. The moulding shall be properly aligned and finished to required shape and profile, including making smooth edges, joints and surface finishing. After fixing, the surface shall be finished with putty, primer coat and two coats of approved paint or colour finish to match the surrouingsurface. The item shall include all materials, labour, scaffolding, finishing, curing and cleaning complete in all respects as directed by the Engineer-in-Charge
596Decorative Slab Cornice MouldingProviding and casting decorative slab cornice moulding in M30 grade cement concrete up to various thickness to RCC slab edges, beams or ceiling portions in approved shape and profile, including necessary centering, shuttering, compacting, finishing and curing, complete as per approved drawings or as directed by the Engineer-in-Charge. 450mm
597Preparation of Instant Lawn : Excavation for planting lawn in earth, soil of all types, soft murum, including removing the excavated material up to a distance of 50 metres. for a depth of 20 centimetres. Supplying on site fresh Garden soil (free from stones rubbish like dried grass roots, other such materials) for excavation area of depth of 20 centimetres. Supplying on site well decomposed Farm Yard Manure for excavation area of depth of 20 centimetres. Providing on site well established (free from weeds/disease etc.) ready to fix lawn turf in slabs/ rolls of required variety as directed. Filling fresh garden soil / silt and manure in excavated area of depth 20cms. Mixing garden soil/silt and manure thoroughly well, watering previous night. Planting required plant species; lawn grass as directed etc. complete for required depth 20 centimetres. for planting lawn/ shrub / flower bed / hedges / edges / canna bed / ground cover. Maintenance of Newly Developed lawn (Instant Lawn) Area. For First 30 days Only.
598Reception Desk:Providing & fixing Reception Desk of required size 3600Lx1200Wx750H in the reception lobby with all the necessary drawers and storage spaces on both side of the table, the drawer shall be operated by inbuilt niche and easily close and open with the assiasatnce of the roller chaneel to enable smooth operation. It has to be made from the 19mm thk. Marine plywood boiling water proof 710 grade and center portion below the table should be void. The top of the table is korean and sides are wrapped with curved corian as shown in the drawing ( As per dwg) etc complete. Mode of Measurement- Measurement of table top.
599Judge’s Chairs:Supplying and placing chair of size 750WX750DX1200H & 450 Seat height and made of seasond sheesham wood finished with melamine polish. Chair to be provided with armrest, seat & backrest to be cushioned & upholstered with faux leather fabric. Legs to be 75X75mm with carving, 50 mm wide & 20 mm thk armrest at 600mm height with carving on backrest as per design & as per approval of engineer in charge. Etc all complete.
600Tables : (Made in situ)Providing and fixing Table as per required size having 750 mm height mad up of 75X75mm legs and binders from seasoned teak wood finished with melamine pu polish & top & central partition below table top in 19mm thk. Marine plywood BWP710 Grade, finished in 4mm thk. Veneer in approved color with PU finish with necessary drawers arrangement operated with telescopic channel of size 1.5” x 20” x 22” on both sides to enable smooth operationand SS Handles including necessary stainless steel fixtures and fastning as per reference design instructions of engineer in charge etc all complete
601(A) Ground Floor
602(B) First Floor
603(C) Second Floor
604Table : (Made in situ):-Providing and fixing A desk based system table with Cube legs are fabricated b powder coated M. S. rectangular pipe of size 40mm X 40mm. Cube legs are available for work top level 750 mm from base. Worktop: 25 mm thk prelaminated plywood with edge binding Material to be supplied by certified ISO 50001:2018, IS0 9001:2015, ISO 1400:2015, ISO 45001:2018, ISO 13485:2016, BIFMA & AIOTA member. Item Should have at least one of the GRIHA/GREENGAURD/GREENPRO/GREEN ASSURANCE Certifications adhering to standard environmental practices. Valid test certificate should be available for the item under consideration. As per reference design and instruction of engineer in charge etc all complete.
605(A) Ground Floor
606(B) First Floor
607(C) Second Floor
608(D) Third Floor
609(E) Fourth Floor
610Staff Tables with Storage : (Made in situ)Providing & fixing Work Surface Staff table with frame fabricated by power coated M.S. rectangular pipe of size 40mm X 40mm. The work top should be made up of 25mm Thick Pre-laminated plywood of BWP 710 grade of approved shaved, Edge banded with matching 2 mm thick PVC lipping. Gromet provided on work Surface for wire management. Add for storage having size 450W x350Lx600H shall be provided to be made up of 25mm Thick Pre- laminated plywood of BWP 710 grade of approved shade with necessary drawers arrangements operated with telescopic channel of size 1.5” x 20” x 22” on both sides to enable smooth operation and below the drawers shlf to be provided for storage including necessary stainless steel fixtures and fastening. Handle is provided for ease of opening. Item should have at least one of the GRIHA/GREENGARUD/GREENPRO/GREEN ASSURANCE Certifications adhering to standard environmental practices. As per reference design and instruction of engineer in charge etc all complete.
611(A) Ground Floor
612(B) First Floor
613(C) Second Floor
614(E) Fourth Floor
615Token Counter Tables:Supplying & Placing table of required size having 750 mm depth and 1050 mm in hight. The worktop shall be 45 mm thick having the combination of 19mm marine ply as top and 25mm thk marine ply as base top. The top shall have approved laminate and shade as well as deco paint with PU coating. The top shall be supported over side storage unit at one end and fixed pedestal unit at another end. The table shall be clad with 19mm thick modesty panel which provide structural support for the table. The table shall have side unite for storage of size 350WX450DX660H made up of 19 mm thk. Marine ply BWP710 Grade of approved make and finished in approved laminate and shade. The drawer shall be operated with SS handle and easily close & open with the assistance of roller telescopic channel of size 1.5” x 20” x 22” on both sides to enable smooth operation. The drawer shall have central locking mechanism in which all the drawer shall be synchronized locked with on single key and including necessary stainless steel fixtures and fastning as per reference design and instructions of engineer in charge etc all complete
616(A) Ground Floor
617(B) First Floor
618(C) Second Floor
619Tables : (Made in Situ):Supplying and placing table of size mentioned below made in 19 Millimeter /12 Millimeter thk. Marine plywood BWP710 Grade of approved make, the worktop shall be 50mm thk finished in 4mm thk. Veneer of in approved color with PU finish. Sides of the table will be supported by 50 mm thk veneer finished frame and the table shall have side unit for storage purpose with 25mm thk shutter, back facia, side panel etc. The drawer shall be operated by inbuilt niche and easily close and open with the assistance of roller telescopic channel of size 1.5” x 20” x 22” on both sides to enable smooth operation. The drawer shall have central locking mechanism in which all in which all the drawer shall be synchronized locked with one single key and including necessary stainless steel fixtures and fastening as per reference design and instructions engineer in charge etc all complete A) Judges Table in courtroom will come with a footrest as per dwg.
620(B) First Floor
621(C) Second Floor
622(D) Third Floor
623(E) Fourth Floor
624Tables : (Made in Situ):Supplying and placing table of size mentioned below made in 19mm/12mm thk. Marine plywood BWP710 Grade of approved make, the worktop shall be 50 mm thk finished in 4mm thk. Veneer of in approved color with PU finish. Sides of the table will be supported by 50mm thk veneer finished frame etc. Including necessary stainless steel fixtures and fastning as per reference design and instructions of engineer in charge etc all complete.Tables : (Made in Situ):Supplying and placing table of size mentioned below made in 19mm/12mm thk. Marine plywood BWP710 Grade of approved make, the worktop shall be 50 mm thk finished in 4mm thk. Veneer of in approved color with PU finish. Sides of the table will be supported by 50mm thk veneer finished frame etc. Including necessary stainless steel fixtures and fastning as per reference design and instructions of engineer in charge etc all complete.B) Lawer’s Table in courtroom will come with 2 mic table and 12mm thk. Touhghened glass divider fixed with all the necessary hardware as per dwg.
625(B) First Floor
626(C) Second Floor
627(D) Third Floor
628(E) Fourth Floor
629Serving Counter : (Made in Situ)Providing & fixing serving counter of size 750Wx2400Lx750H in the canteen. The counter to be made up of 19mm thk. Maine BWP710 grade plywood frame structure below and Granite top above fixed on commercial marble by araldite. Below the table provide Storage areas with partition and lockable shutters & 1mm thk. Approved make laminate on the outside & inside with 75mm high skirting operated with SS Handles and neccesaary fixtures and fastening as per reference design and instructions of engineer in charged etc all complete.
630Pantry Counter : ( Made in situ)Providing & fixing pantry counter of required length having size 750W and 850H in the canteen. The counter to be made up of 19mm thk. Marine BWP 710 grade plywood frame structure below and Granite top above fixed on commercial marble by araldite. Below the table provide storage areas with stainless steel kitchen trolley of overall 26” height and 22” depth , supported on aluminium pipes, trolley basket made of 5mm stainless steel rod fitted on telescopic channel of size 1.5” x 20” x 22” on both sides of trolley of 12” or above size, panel having 40 Kilogram load bearing capacity of trolley made out of 20 mm PUC Coated plywood and colour combinations as directed by E-I-C. Inner side of panel covered by white mica, 100mm s.s. decorative handle. ( The width and height of individual compartments shall be kept as directed by Engineer-in-charge) with neccesaary fixtures and fastening as per reference design and instructions of engineer in charged etc all complete.
631(B) First Floor
632Court Room : Dias Railing ( Made in situ)Providing and fixing dias railing in court room of size 975mm height and 100 mm thickness including 19mm thick 50x 50mm plywood frame in 600mm c/c covered with 12mm plywood from both sides and finished in 4mm thick veneer with P.U. Polish. Including 100x50mm top rail of seasoned teak wood supported on 50 mm dia wooden balusters should be provided on top of the rail. Also the provision of 750mm wide shutter of same specifications should be added for movement with all necessary fixtures and fastening as per design & drawing and instructions of engineer in charge etc. complete.
633(B) First Floor
634(C) Second Floor
635(D) Third Floor
636(E) Fourth Floor
637Court Room: Criminal bench Railing (Made in situ)Providing and fixing dias railing of size 900mm in height and 50 mm thick including 50mm x 50mm battenes of seasoned teak wood horizontal support in 150 mm interval supported vertically with 50mm x 50mm and 50mm x 25mm battens os seasoned teak wood in 600mm intervals alternatively including finished with melamine PU Polish with all fixtures and fastenting as per design & drawing and instructions of engineer in charge etc. complete
638(B) First Floor
639(C) Second Floor
640(D) Third Floor
641(E) Fourth Floor
642Storage (Made in situ)Providing and fixing storage units of specified size having 450 mm depth upto 1.5m in length and 750 mm height made up of 19mm thk. Marine playwood BWP710 of approved make finished in 4mm thk. Veneer in approved color with PU finish outside and 1mm thk. Laminate on the inside with 75mm high skirting & appropriate quantity of shelfs and the shutters shall have central locking mechanism in which all the drawer shall be synchronized loked with one single key as per reference design and instructions of engineer in charge etc. all complete.
643(A) Ground Floor
644(B) First Floor
645(C) Second Floor
646Storage (Made in situ)Providing and fixing storage units of specified size having 450 mm depth Above 1.5m to 5.0 in length and 750 mm height made up of 19mm thk. Marine playwood BWP710 of approved make finished in 4mm thk. Veneer in approved color with PU finish outside and 1mm thk. Laminate on the inside with 75mm high skirting & appropriate quantity of shelfs and the shutters shall have central locking mechanism in which all the drawer shall be synchronized locked with one single key as per reference design and instructions of engineer in charge etc. all complete.
647(A) Ground Floor
648(B) First Floor
649(C) Second Floor
650Court Room : Witness Box ( Made in Situ)Providing and fixing court room witness box of size 1350Wx1150Lx1050H, with ramp and step in Marine plywood BWP710 Grade finished in 4mm thk. Veneer in approved color with PU finish and railing & flooring made up of seasoned teak wood with mic stand as per reference design and instructions of engineer in charge etc all complete.
651Court Room : Criminal Bench ( Made in situ)Providing and fixing court room criminal bench of various size having 450 m width and 450 height made up of 19mm thk. Marine plywood BWP710 Grade of approved make, finished in 4mm thk. Veneer of approved make in approved color with PU finish as per reference design and instructions of engineer in charge etc. all complete.
652(A) First Floor
653(B) Second Floor
654(D) Third Floor
655(E) Fourth Floor
656Kitchen Counter Storage with kitchen TrolleyProviding and Fixing kitchen counter storage of required size with Granite top of 18mm thickcarcass made from marine plywood BWP710 Grade. Below the table provide storage areas with stainless steel kitche trolley of overall 26” height and 22” depth, supported on aluminium pipes, trolley basket made out of 5mm stainless steel rod fitted on telescopic, channel of size 1.5” x 20” x22” on both sides of trolley of 12” or above size, panel having 40Kilogramload bearing capacity of trolley made out of 20 mm PUC Coated plywood and colour combination as directed by E-I-C . Inner side of panel covered by white mica , 100mm s.s. decorative handle. ( The width and height of individual compartments shall be kept as directed by Engineer-in-charge) with necessary fixtures and fastenting as per reference design and instruction of engineer in charged etc all complete.
657(B) First Floor
658Full Ht. Solid Partition: (Made in situ)Providing and fixing Full height partition of minimum 65 mm thick made by using aluminium frame with 50x50 mm vertical members equally spaced at 600c/c fixed with 4mm thick veneer of approved make fixed on 12mm thick BWP710 grade marine plywood of the requisite manufacturer of approved make finished with melamine polish etc complete. 6mm thick clear glass fixed with necessary fixtures and fastenings as shown in the Drawing all complete as per instructions of engineer in charge. With guarantee of 10 years.
659(A) Ground Floor
660(B) First Floor
661(C) Second Floor
662Half Ht. Solid Partition : (Made in situ)Half height partition upto 1.5m (5’) ht. and minimum 65 mm thk made by using 50x50 mm vertical members equally spaced aluminium frame at 600c/c fixed with 12mm thick BWP710 grade marine plywood of the requisite manufacturer optima 710/Kenwood/Chetak make. Confirming to IS 303/IS710-1980 finished with anti termite treatment etc. complete. On either side finished with approved 4 mm thick veneer of Naturals/Gracious/Silicon (color and finish as per specifications) etc all per instructions of engineer in charge. As per Drawing with guarantee of 10 years.
663(A) Ground Floor
664(B) First Floor
665(C) Second Floor
666Venner Panelling: (Made in situ)Providing and fixing 4mm thick or oak veneer panelling on walls of Naturals/Gracious/Silicon make on plywood backing made out of 50*25 mm thick C.C.T.W. frame work of size 600 *600mm centre or as per site condition covered by 12mm thick BWP710 grade marine plywood of the requisite manufacturer of approved make with melamine polish etc. complete as per Architectural drawings and Instructions of Engineer Incharge. With guarantee of 10 years.
667(B) First Floor
668(C) Second Floor
669(D) Third Floor
670(E) Fourth Floor
671CMM wall-Hung Cabinet : (Made in situ)Providing and fixing CMM Wall-Hung Cabinet of 400 mm depth to be made in 19 mm thk. Marine ply of approvd make with post from edge with shutters of 19mm thick marine plywood of approved make with lamination with all necessary fixtures and fastening as per reference design & provision of ventilation as per selection of engineer in charge etc. complete
672(A) Ground Floor
673Bookracks : Judges Chamber (Made in situ)Judge’s Office -Bookrack : Providing storage bookrack cabinet made in 19mm thk. Marine plywood BWP710 Grade of approved make, finished in 4mm thk. Veneer of Naturals/Gracious/Silicon in approved color. Shutter with aluminium frame made in 6mm thk. Clear toughened glass of Saint Gobain or similar make with lock mechnimsm. Internal shelves to have a clear height of not less than 350mm.
674(A) Ground Floor
675(B) First Floor
676(C) Second Floor
677(D) Third Floor
678(E) Fourth Floor
679Court Room : Dias Flooring (Made in situ)Providing and fixing 12mm thick 150 mm strips of seasoned teak wooden dias flooring with PU polish as per design & drawing and instruction of engineer in charge. etc complete.
680(B) First Floor
681(C) Second Floor
682(D) Third Floor
683(E) Fourth Floor
684Single Seater Wooden Chairs : ( courtroom and judges chamber)Solid Wood Chair of size 550W x 500 D x 800H made of seasoned Teak wood finished with melamine polish. Chair to be provided with armrest, seat to be cushioned & upholestered with selected fabric. There is a non-slip mute pad at the bottom of the leg to rescue noise and protect the floor from scratches. The back of the chair is curved and fits the back for added comfort. Cushion pad filled with high resilience sponge, comfortable sitting, sedentary not tired as per design & as per approval of engineer in charge, achitects and users. etc all
685(A) Ground Floor
686(B) First Floor
687(C) Second Floor
688(D) Third Floor
689Providing & fixing plywood platform of specified height using 25mm thk blockboard of BWP710 grade in 600x600mm grid and top should be covered in 25 Millimeter thk blockboard of BWP710 grade with all the required hardwares as per design & as per approval of engineer in charge etc all complete.
690Sofa Set 3+1+1 Providing & fixing Sofa Set 3+1+1 Brown and Cream leather DIMENSION Length: 182.5 (centimetre) Breadth (centimetre)): 100 (centimetre)Height (centimetre): 100 (centimetre) Weight (kilograms): 66 (kilograms) Seating Capacity: Five Seat
691(B) First Floor
692(C) Second Floor
693(D) Third Floor
694(E) Fourth Floor
695Public Seating Chair. - 3 SeaterProviding and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish.
696(A) Ground Floor
697(B) First Floor
698(C) Second Floor
699Conference Table @ 3600Lx1400Dx750HT : Providing & Fixing of Main Table @ 3600Lx1400Dx750HT - made up of 18+18millimetre Thick MDF top with Poly vinyl chloride Membrane finish and waterfall edge profile. Aluminium Anodizied finish beeding of 4millimetre thich is running all over the table top edge. Gable ends is Aerofoiled Shape with front edges in Poly vinyl chloride Membrane finish and rest in Prelaminated MDF with batton structure. Gable ends should be hollow from inside for the provision of passing electrical and Data wiring. , MODESTY PANEL:- to be made of 18 millimetre thick Prelaminated particle board with Poly vinyl chloride edge band. Access Flap:- For Wire manager 2 Numbers.
700Multiple Compartment Lockers @ 1140Lx 457D x 1830 Millimeter Ht.Providing and fixing Multiple Compartment Lockers @ 1140Lx 457D x 1830 Millimeter Ht. with 12 Compartments , Complete body & shutter made of CRCA Sheet with powder coated finish as per approved color.
701Providing & Fixing 12mm thick Toughned Glass Partition with rubber Gasket inlcluding fixtures & fastening etc. complete
702Providing and Fixing Rollar Blinds AMI Make or approved make & shade of 38mm round Aluminium channel with Blackout fabric & telting with chain (Ball) system with all necessary fixtures and fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work)
703(A) Ground Floor+D12
704(B) First Floor
705(C) Second Floor
706Providing & Fixing 12 Millimeter thick Toughned Glass Door with rubber Gasket inlcluding fixtures & fastening etc. complete
707Estimate No : 4136A of 2026-2027-Providing Electrification, Water Pump, LAN Wiring, Telephone Wirirng, Air Conditioning, APFC Panel & Street Lights
708Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC [1-1-9]
709Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC [1-1-10]
710Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit [1-2-2]
711Supplying and erecting green colour earthing with 1x 1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1]
712Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-2]
713Supplying and erecting green colour earthing with 1x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-2]
714Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-3]
715Supplying and erecting green colour earthing with 1x 4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-3]
716Supplying and erecting mains with 4x 6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-4]
717Supplying and erecting green colour earthing with 1x 6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-4]
718Supplying and erecting mains with 4x 10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-5]
719Supplying and erecting green colour earthing with 1x 10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-5]
720Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV [1-3-14]
721Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV [1-3-15]
722Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. [1-6-1]
723Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. [1-6-2]
724Supplying and erecting modular type 3 pin 6A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-10]
725Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-11]
726Supplying and erecting modular type T.V. socket single outlet duly erected on provided plate and box with wiring connections complete. [1-6-14]
727Supplying and erecting modular type telephone socket one gang with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-15]
728Supplying and erecting modular type (two module) electronic step regulator for fan duly erected on provided plate and box with wiring connections complete. [1-6-23]
729Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-34]
730Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-35]
731Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-36]
732Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-38]
733Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-39]
734Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-40]
735Supplying and erecting 16 to 32 A 10kA DPMCB suitable to fix in 2 module of modular switch in provided box complete & duly concealed with necessary material and connected. [1-6-45]
736Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW [1-7-5]
737Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW [1-7-6]
738Wiring for plug on board with Switch socket surface/concealed type copper wiring and earthing and with modular accessories as per specification No WG-PW/CW [1-7-26]
739Supplying and erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation polyester taped Nylon Rip Cord & grey colour sheathed with FR PVC conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW [1-8-1]
740Supplying and erecting 20 pair 0.5mm dia jelly filled unarmoured telephone copper cable with poly-al laminate moisture barrier laid in provided PVC casing capping/conduit as per specification No. WG-TW [1-8-10]
741Supplying and erecting co-axial copper cable low voltage grade tri-shielded RG-6 as per specification No. WG-TW [1-8-19]
742Supplying, Erecting and Commissioning of MDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW [1-9-1]
743Supplying, Erecting and Commissioning of 20 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW [1-9-12]
744Supplying, Erecting and Commissioning of digital (hybrid) type EPABX of 6 x 32 extensions suitable upto 96 extensions complete. [1-9-26]
745Supplying, Erecting and Commissioning of push button telephone instrument desk top/wall mount with caller ID & Speaker unit as per specification complete. [1-9-29]
746Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC [1-10-1]
747Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC [1-10-16]
748Supplying, fixing, and configuring 8-ports 1 G unmanaged gigabit POE switch erected in provided rack complete. [1-11-1]
749Supplying, fixing, and configuring 24 ports with 4 (SFP+) port ethernet managed switch with web view/CLI 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WG-NWC/GBS [1-11-4]
750Supplying, fixing, and configuring broadband ADSL router with all accessories on provided rack as per specification No. WG-NWC/ADSL [1-11-17]
751Supplying, installing & testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. [1-12-1]
752Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO [1-12-2]
753Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP [1-12-4]
754Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK [1-12-17]
755Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing polystyrene diffuser having system lumens output of Min. 770 Lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-2]
756Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing polystyrene diffuser having system lumens output of Min. 2000 Lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-5]
757Supplying and erecting LED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing polystyrene diffuser having system lumens output of Min. 2750 Lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-6]
758Supplying and erecting LED Panel Light(600mm X 600mm) Max. 30 W having CRCA powder coated housing polystyrene diffuser having system lumens output of Min. 3600 Lumens min. efficacy of 120 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-7]
759Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6000K Beam Angle of 110 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 200-270V surge protection of 2 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided PVC Block / wooden board with 3 years warranty. [2-1-16]
760Supplying and erecting CRCA powder coated corridor/passage light LED fitting (4 feet) Max. 17W with high transitivity diffuser with system lumens output of Min. 2000 lumens min. efficacy of 120 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 4 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided PVC Block / wooden board with 3 years warranty. [2-1-17]
761Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size. [2-3-13]
762Supplying and erecting integrated LED street light fitting 23 to 25W IP65 & IK08 class having single piece pressure die-cast aluminium housing having system lumens output of Min. 2300 Lumens min. efficacy of 100 lumen/W CRI>70 CCT upto 6500K THD<10% p.f. >0.95 operating range of 140-270V inbuilt surge protection of 10 kV Life class of 50 000 Hrs. at L70B50 including driver complete with 3Years warranty as per specification No FG-ODF/FLS2. [2-4-2]
763Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing having system lumens output of Min. 4400 Lumens min. efficacy of 110 lumen/W CRI>70 CCT upto 6500K THD<10% p.f. >0.95 operating range of 140-270V inbuilt surge protection of 10 kV Life class of 50 000 Hrs. at L70B50 including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. [2-4-4]
764Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08 class having single piece pressure die-cast aluminium housing having system lumens output of Min. 7700 Lumens min. efficacy of 110 lumen/W CRI>70 CCT upto 6500K THD<10% p.f. >0.95 operating range of 140-270V inbuilt surge protection of 10 kV Life class of 50 000 Hrs. at L70B50 including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. [2-4-6]
765Supplying and erecting integrated LED flood light fitting Max. 120W IP65 & IK07 class having pressure die-cast aluminium housing having system lumens output of Min.14500 Lumens min. efficacy of 120 lumen/W CRI>70 CCT upto 6500K THD<10% p.f. >0.90 operating range of 140-270V inbuilt surge protection of 4 kV Life class of 50 000 Hrs. at L70B50 including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2. [2-4-16]
766Supplying and erecting integrated LED Bollard Cylindrical/Cubical shaped 800mm 8W IP65 & IK10 class having extrusion aluminium housing with polycarbonate diffuser having system lumens output of Min. 800 Lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6500K THD<10% p.f. >0.90 operating range of 140-240V inbuilt surge protection of 2 kV Life class of 25 000 Hrs. at L50B50 including driver complete with 2 Year warranty as per specification No FG-ODF/FLS2. [2-4-20]
767Supplying and erecting street light Wall bracket made from 25 mm. dia G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB [2-7-3]
768Supplying and erecting street light Wall bracket made from 40 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB [2-7-4]
769Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades wire mesh duly erected complete. [2-10-14]
770Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF [2-10-21]
771Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original. [2-11-4]
772Supplying and erecting storage type water heater 15 litres capacity having standing loss <0.419 kWh / 24 hour / 45°C high impact resistance engineering plastic body with anti corrosive high grade steel inner tank heating element having hard water & corrosion protection with minimum 3 safety protections (i.e. thermostat & thermal cut-out multi function valve) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no. AP-WH/STWH [3-1-1]
773Supplying, installing, testing and commissioning of split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 5.00 suitable to operate on 250V 50 Hz A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser minimum 2.5PM filter self diagnosis feature stabilizer free operation & temperature display on indoor unit noise level maximum 50dBA at position as per specification no. APAC/ WAC [3-2-11]
774Supplying, installing, testing and commissioning of split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor. room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 5.0 suitable to operate on 250V 50 Hz A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser minimum 2.5PM filter self diagnosis feature stabilizer free operation & temperature display on indoor unit noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP-AC/WAC [3-2-13]
775Supplying, erecting, testing and commissioning of self contained water cooler 230/250V 50Hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. AP-WCR/WC [3-3-10]
776Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200) [3-5-1]
777Supplying, installing, testing and commissioning of 6kVA capacity online pure sine wave with backup time of ....... hrs. PWM & IGBT based UPS with 0.9 to unity output pf single phase input & 1 phase output complete with all protections as per specification no. AP-UPS [3-7-4]
778Supplying and erecting 12V/42Ah SMF battery with battery terminal wire duly charged with 24 months warranty complete [3-8-10]
779Providing vaccumising the airconditioner system to 200 micron and charging with refrigerant R32 for AC unit. [3-10-24]
780Supplying, erecting, testing and commissioning of 6HP VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant for minimum cooling capacity as delivering 100% capacity at 47° C non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00 modular type horizontal hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area rain protection cover built in oil separator accumulator and oil receiver copper tube aluminium fin air cooled condenser condenser fan with motor suitable for 415V±10% 50 Hz 3 phase power supply (all suitable for high ambient conditions) internal copper refrigerant piping internal wiring and refrigerant etc. all housed in powder coated weather proof cabinet complete. [3-11-1]
781Supplying, erecting, testing and commissioning of 14HP VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant for minimum cooling capacity as delivering 100% capacity at 47° C non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00 modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area rain protection cover built in oil separator accumulator and oil receiver copper tube aluminium fin air cooled condenser condenser fan with motor suitable for 415V±10% 50 Hz 3 phase power supply (all suitable for high ambient conditions) internal copper refrigerant piping internal wiring and refrigerant etc. all housed in powder coated weather proof cabinet complete. [3-11-5]
782Supplying, erecting, testing and commissioning of 20HP VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant for minimum cooling capacity as delivering 100% capacity at 47° C non stop cooling even at 56°C and coefficient of performance (COP) 3.00 to 4.00 modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area rain protection cover built in oil separator accumulator and oil receiver copper tube aluminium fin air cooled condenser condenser fan with motor suitable for 415V±10% 50 Hz 3 phase power supply (all suitable for high ambient conditions) internal copper refrigerant piping internal wiring and refrigerant etc. all housed in powder coated weather proof cabinet complete. [3-11-8]
783Supplying, erecting, testing and commissioning of 24HP VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant for minimum cooling capacity as delivering 100% capacity at 47° C non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00 modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area rain protection cover built in oil separator accumulator and oil receiver copper tube aluminium fin air cooled condenser condenser fan with motor suitable for 415V±10% 50 Hz 3 phase power supply (all suitable for high ambient conditions) internal copper refrigerant piping internal wiring and refrigerant etc. all housed in powder coated weather proof cabinet complete. [3-11-10]
784Supplying, erecting, testing and commissioning of VRF/VRV based Hi-wall type room/indoor unit (IDU) of nominal cooling capacity 1.0TR (358 cfm) to 1.25TR (417 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor copper tube aluminium fin evaporator coil washable air filter insulated drain tray in built drain pump expansion device cordless remote control with necessary controls and electrical terminal to receive power supply etc. IDU shall have anti-corrosive coating suitable for coastal area. Unit shall be of decorative slim dimension suitable indoor wall mounting. The indoor unit shall also have an electronic control console. The unit shall be suitable for wall mounting and provided with suitable mounting brackets with any additional refrigerant and oil charge as per requirement during installation complete. [3-11-14]
785Supplying, erecting, testing and commissioning of VRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling capacity 1.8TR (594 cfm) to 2.2TR (655 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor copper tube aluminium fin evaporator coil washable air filter insulated drain tray expansion device cordless remote control with necessary controls with 3-core copper flexible cord of required length and electrical terminal to receive power supply etc. IDU shall have anticorrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting having an electronic control console provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation connected to the system complete. [3-11-16]
786Supplying, erecting, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact/standard size) of nominal cooling capacity 2.0TR (618 cfm) to 2.3TR (671 cfm) having EER as per BEE standards and specifications suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements fan refrigerant liquid and refrigerant piping cordless remote control and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase 230V 50Hz AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. [3-11-20]
787Supplying, erecting, testing and commissioning of VRV / VRF based ductable type high static room/indoor unit (IDU) having nominal cooling capacity of 8.0TR (3200 cfm) having EER as per BEE standards and specifications with evaporator fan with motor copper tube aluminium fin evaporator coil washable air filter insulated drain tray in built drain pump expansion device cordless remote control with necessary controls and electrical terminal to receive power supply etc. having anti-corrosive coating suitable for coastal area and decorative slim dimension suitable for ceiling suspended arrangement with an electronic control console and any additional refrigerant and oil charge as per requirement during installation complete. [3-11-56]
788Supplying, erecting, testing and commissioning of fresh air intake system ductable circular inline fresh air fan inlet unit having 300 cfm capacity with maintaining the static pressure minimum 20mm suitable to operate on 1 phase 230V 50Hz A.C. supply complete. [3-11-60]
789Supplying and erecting circular flexible/rigid PVC pipe duct of size 100mm dia 4mm thickness with required couplers reducers T-joints Y-joints elbows and necessary supports etc. with sealing with provided control/air flow regulating valves / dampers filters at position complete. [3-11-65]
790Supplying and erecting circular flexible/rigid PVC pipe duct of size 150mm dia 4mm thickness with required couplers reducers T-joints Y-joints elbows and necessary supports etc. with sealing with provided control/air flow regulating valves/dampers filters at position complete. [3-11-66]
791Supplying and erecting an air flow regulating valves/dampers in provided flexible or rigid duct/pipe of 40mm size with an alteration for existing flexible PVC pipe duct and necessary joints sealing couplings at position complete . [3-11-68]
792Supplying and erecting an air flow regulating valves/dampers in provided flexible or rigid duct/pipe of 50mm size with an alteration for existing flexible PVC pipe duct and necessary joints sealing couplings at position complete. [3-11-69]
793Supplying and erecting an air flow regulating valves/dampers in provided flexible or rigid duct/pipe of 150 mm size with an alteration for existing flexible PVC pipe duct and necessary joints sealing couplings at position complete. [3-11-72]
794Supplying and erecting an air flow regulating valves/dampers in provided flexible or rigid duct / pipe of 200 mm size with an alteration for existing flexible PVC pipe duct and necessary joints sealing couplings at position complete. [3-11-73]
795Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. [for Quantities more than 30 rates reduced by 20%] [3-11-77]
796Supplying, erecting, testing and commissioning of wireless remote control having colour LCD panel real time clock temperature limitation (16 to 30° C functions like filter clean reminder timer suitable to communicate with wired controller complete. [3-11-78]
797Supplying, erecting, testing and commissioning of centralised programmable remote control panel (HMI) touch manager controls minimum 16 system of 64 ODU's can be controlled and up to 992 IDU's can be individually mounted and controlled indoor units having colour min 200mm size LCD touch panel yearly schedule power proportional distribution function temperature limitation history function complete erected on wall integrated with provided fire alarm system. [3-11-79]
798Providing adhesive thermal insulation for supply return air duct with 19mm nitrile rubber insulation having R-value as per the prevailing provisions in ECBC-2017. [3-11-83]
799Providing & applying of acoustic insulation for air ducts with 25mm thick 48 kg/cu.m fiber glass faced with RP tissue and covered with 26 SWG perforated aluminium sheets complete. [3-11-84]
800Supplying and erecting tile type modular diffuser made from aluminium sheet with powder coated matching to the ceiling shade for provided supply and return air complete. [3-11-85]
801Supplying and installing of high pressure grade required size copper connection Y or T- Joints/refnet complete erected on wall/ceiling with supports/raceways Nitrile rubber insulation painting etc. with brazing and testing for leakages confirming the normal operation of the VRV/VRF air conditioning system. [3-11-86]
802Supplying and installing of collar damper of galvanised iron material of upto 120 microns for anti corrosive resistance for supply air grill of suitable size. [3-11-87]
803Supplying and erecting aluminium powder coated linear grill of suitable size for width length without collar dampers having matching colour with the existing false ceiling and suitable for deflection of 15/30/45°. [3-11-88]
804Supplying, laying / fixing, testing and commissioning of of appropriate nominal refrigerant copper pipe of 34.9mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports hangers clamps vibration isolators and fittings such as bends tees valves gauges strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages fungal growth flame spread water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete. [3-11-90]
805Supplying, laying / fixing, testing and commissioning of of appropriate nominal refrigerant copper pipe of 28.6mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports hangers clamps vibration isolators and fittings such as bends tees valves gauges strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages fungal growth flame spread water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete. [3-11-91]
806Supplying, laying / fixing, testing and commissioning of of appropriate nominal refrigerant copper pipe of 22.2mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports hangers clamps vibration isolators and fittings such as bends tees valves gauges strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages fungal growth flame spread water permeance and ultraviolet radiation with OEM standards of VRV/VRF air conditioning system complete. [3-11-92]
807Supplying, laying / fixing, testing and commissioning of of appropriate nominal refrigerant copper pipe of 19.1mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports hangers clamps vibration isolators and fittings such as bends tees valves gauges strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages fungal growth flame spread water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete. [3-11-93]
808Supplying, laying / fixing, testing and commissioning of of appropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports hangers clamps vibration isolators and fittings such as bends tees valves gauges strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages fungal growth flame spread water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete. [3-11-94]
809Supplying, laying / fixing, testing and commissioning of of appropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports hangers clamps vibration isolators and fittings such as bends tees valves gauges strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages fungal growth flame spread water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete. [3-11-96]
810Supplying, laying / fixing, testing and commissioning of of appropriate nominal refrigerant copper pipe of 6.4mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports hangers clamps vibration isolators and fittings such as bends tees valves gauges strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages fungal growth flame spread water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete. [3-11-97]
811Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 32 mm for solar water heater/AC system. [4-2-14]
812Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 42 mm for solar water heater/AC system. [4-2-15]
813Supplying and erecting 25/32 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC) thickness 3.2 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC [4-2-19]
814Supplying and erecting 32/40 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC) thickness 3.8 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC [4-2-20]
815Supplying and erecting four pole ON LOAD change over switch 415V 32A open execution having staggered termination phase barrier shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit rotary handle operational current category AC23A complying to IS/IEC 60947-3 Part-1/3 [5-1-1]
816Supplying and erecting three phase 415V street light control panel up to the max load of 12kW TPN MCB 63A powder coated CRCA 14 SWG sheet outdoor type having IP54 IK10 protection suitable rating contactor 24 hrs. astronomical time switch with minimum 5 years battery back up auto/manual selector switch ON/OFF push buttons indicator lamps control wiring metering device etc. for automatic operation with overcurrent short circuit earth fault protection on provided iron frame / CC foundation. [5-2-6]
817Supplying, erecting and marking SPMCB 6A to 32A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-2]
818Supplying, erecting and marking SPMCB 6A to 32A B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-3]
819Supplying, erecting and marking TPMCB 6A to 32A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-10]
820Supplying, erecting and marking TPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-11]
821Supplying, erecting and marking FPMCB 6A to 32A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-12]
822Supplying, erecting and marking FPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-13]
823Supplying and erecting triple pole and neutral distribution board (TPNDB) SPMCB of 4 ways/phase (12 poles) with door 1.2mm thickness surface/flush mounted IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB [5-4-1]
824Supplying and erecting triple pole and neutral distribution board (TPNDB) SPMCB of 8 ways / phase (24 poles) with door 1.2mm thickness surface/ flush mounted IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB [5-4-2]
825Supplying and erecting triple pole and neutral distribution board (TPNDB) SP/TP MCBs total 4 ways /12 Poles with door 1.2mm thickness surface/flush mounted IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB [5-4-4]
826Supplying and erecting triple pole and neutral distribution board (TPNDB) SP/TP MCBs total 8 ways /24 poles with door 1.2mm thickness surface/flush mounted IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB [5-4-5]
827Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. [5-4-13]
828Providing and erecting 4 Pole MCCB 415 V 100A rated short-circuit breaking capacity 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and fixed magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [5-5-1]
829Providing and erecting 4 Pole MCCB 415V 200A rated short-circuit breaking capacity 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides with insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [5-5-2]
830Providing and erecting 4 Pole MCCB 415V 400A rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides with insulation withstand capacity 800V no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB [5-5-4]
831Supplying, Erecting and Commissioning of 4 pole RCCB 40A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-5]
832Supplying, Erecting and Commissioning of 4 pole RCCB 63A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-6]
833Supplying and erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 100A [5-10-26]
834Supplying and erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 200/300A [5-10-27]
835Supplying and erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 400A [5-10-28]
836Supplying and erecting terminal spreaders suitable for 4 pole up to 100A MCCB (Set of 8) [5-11-6]
837Supplying and erecting terminal spreaders suitable for 4 pole above 100A up to 250A MCCB (Set of 8) [5-11-7]
838Supplying and erecting terminal spreaders suitable for 4 pole above 250A up to 400A MCCB (Set of 8) [5-11-8]
839Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB. [5-11-14]
840Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for above 250A up to 630A MCCB. [5-11-15]
841Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes panel boards etc. including cutting bending drilling welding riveting treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. [6-1-1]
842Supplying and erecting GI sheet 0.6 mm (24 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629 1985 to be used for fabrication of boxes panel boards etc. including cutting bending drilling welding riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. [6-1-2]
843Supplying and erecting GI sheet 0.8 mm (22 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629 1985 to be used for fabrication of boxes panel boards etc. including cutting bending drilling welding riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. [6-1-3]
844Supplying and erecting plywood 12 mm thick fixed to wall or on provided panel board with necessary materials such as screws wall fasteners supports nuts bolts etc. complete. [6-1-12]
845Supplying and erecting iron work sheet metal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. [6-1-19]
846Supplying and erecting self-locking arrangement with keys in duplicate made of brass of grade 1 compliance to IS 729-1979 duly erected flush with surface of panel / cupboard [6-1-20]
847Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP-BB [6-2-11]
848Supplying and erecting dual source intelligent flush mounted panel meter three phase four wire (IPM) 415V CT/ PT site programmable class I flush mounted (96 x 96 mm) meter with voltage current frequency power factor ON hrs kWh EB and DG set metering with LED display (excluding CT'S) complete with RS 485 communication protocol class I accuracy and wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer. [6-3-10]
849Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates. [6-5-2]
850Supplying and erecting LED type indicating pilot lamp with LED colours red / yellow / green 230 / 250V on provided box / panel with necessary material wiring & connections etc. [6-5-5]
851Supplying and erecting LED type indicating pilot lamp with LED colour blue 230 / 250 V on provided box / panel with necessary material wiring & connections etc. [6-5-6]
852Supplying and erecting 125 kVAr 440 V 3 phase 50 Hz. Contactor Logic & Intelligent Relay micro APFC passive filter panel consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no CP-ED/APFC [6-7-6]
853Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3 core 2.5 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-7]
854Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3 core 6 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-9]
855Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-15]
856Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-18]
857Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-19]
858Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-24]
859Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-27]
860Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-28]
861Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-29]
862Supplying and erecting G.I. pipe ‘A’ class 25 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE [7-6-1]
863Supplying and laying (including excavation) of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface to required depth complete. [7-6-9]
864Providing and erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 100 mm height comprising all required standard accessories. [7-11-2]
865Providing and erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 100 mm height comprising all required standard accessories. [7-11-3]
866Providing and erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware. [7-11-8]
867Providing and erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 300 mm width & 20 mm height complete with necessary hardware. [7-11-13]
868Supplying and erecting 12.5 m (clear height) motorized high-mast (Top -150mm Bottom- 360mm) hot dipped galvanized material with average minimum thickness 65 micron made from high tensile structure grade steel as per BSEN - 10025 S 355/E350 & 3mm thickness with base plate 25 mm thick x OD 520 mm grade as per IS-2062 pole made in single section & submerge arc welded with lowering & raising motorized unit wire rope stainless steel 316 grade 2 nos. 7x19 construction 5mm SG-DG U clamps double drum with assembly 250 kg 5x2.5 Sq.mm. flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box lightning arrestor arrangement for fixing aviation light high-mast with serial number factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with necessary accessories complete as per specification no. OH-PL/HM (excluding luminaries) [8-2-1]
869Providing and erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 155 mm A/F top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL [8-2-16]
870Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT [8-2-21]
871Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT [8-2-22]
872Supplying and erecting outdoor stand mounted feeder pillar for high-mast of the same manufacturer with 32A TPN MCB incomer 24hr astronomical time switch with minimum 5 years battery backup IP 54 and IK10 protection 25 A TP contactor for automatic switching of luminaires 2 no. 9A contactors and raise/lower push button and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 SWG CRCA sheet box with supporting angles self lock gasket and slanting top erected on CC foundation complete. [8-2-23]
873Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-1]
874Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP [9-1-4]
875Supplying and erecting aluminium strip of high purity required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint with joints required as per specification no EA-EP. [9-2-1]
876Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. [9-2-3]
877Supplying and erecting minimum Three & above star rated submersible pump set of 5.625 KW/7.5 HP with 415 V 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 110 to 510 LPM discharge at 107 to 30 m head & discharge & delivery pipe of Size-50 mm diameter with a necessary H type clamps as per specification No. WP-SMP [12-2-10]
878Supplying and erecting minimum Three & above star rated 3 phase 415 V 50 Hz submersible pump set of 7.5 KW/10HP suitable for erection on open well pump having delivery head from 72 to 28 m and discharge from 120 to 840 litres. per minute & pipe of Suction 65 mm/Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP [12-3-7]
879Supplying and erecting flat flexible 3 core 6 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. [12-4-10]
880Supplying and erecting automatic control panel for 3 Phase 415 volt A.C Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP S.P.P. Combined ammeter/ voltmeter phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing phase reversal phase imbalance etc . [12-4-17]
881Supplying and erecting automatic control panel for 3 Ph 415 volt A.C. Submersible/centrifugal pump set up to 7.5 HP - 10 H.P. consisting of DOL starter having relay range 13-21 AMP S.P.P. Combined ammeter/voltmeter phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing phase reversal phase imbalance etc. [12-4-18]
882Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel concrete excavation and fixing provided nut bolts with the help of template duly plastered as per design complete (for 9m & 10m high octagonal /conical GI pole). [16-3-10]
883Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template duly plastered as per design complete (for 12.5 m raising lowering high mast). [16-3-12]
884Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP. [16-5-6]
885Supplying and erecting ISI mark GI pipe 65 mm. dia. ‘B’ class at position with accessories complete as per specification no. CW-PLB/GP. [16-5-7]
886Supplying and erecting high density polythene pipe ISI mark 50 mm. dia. suitable for pressure of 6 kg. / cm2 connected to jet/submersible pump with required material complete. [16-5-18]
887Supplying and erecting 50 mm dia. gun metal sluice valve at position with necessary materials complete. [16-6-15]
888Supplying and erecting non return valve 50 mm dia in position made of gun metal complete. [16-6-21]
889Supplying and erecting non return valve 65 mm dia in position made of gun metal complete. [16-6-22]
890Estimate No. 4136B/2026-27 Providing and Installing Fire Alarm & Fire Fighting System to Newly Constructed Additional District and Session Court at Chalisgaon. Tal. Chalisgaon. Dist. Jalgoan.
891Carrying out core cutting of size 3\\" to 5\\" dia x 15\\" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. ( for quantities more than 30 rates reduced by 20%)
892Providing and fixing high-density polyethylene (HDPE) container one piece moulded triple layer water tank made out of high density polyethylene and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow pipe inclusive of all tanks capacity up to 20000 litres.
893Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
894Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
895Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
896Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
897Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
898Supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
899Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 100 mm height comprising all required standard accessories.
900Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
901Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
902Supplying & erecting D.O.L Starter suitable for 415 V, 3 phase 50 cycles with no volt coil and overload element with necessary materials and connected to supply for 10 H.P.
903Supplying, installation, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 2280 to 2850 LPM at 140 to 120 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 93kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal type, single/multi stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/MSC/EP
904Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 90 to 70 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 9.3 kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as per specification no. FF-MFP/JP
905Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 900 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 7.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d)Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP
906Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 120 to 90 m head driven by 110 HP or suitable HP capacity diesel engine at required working speed suitable for automatic operation and consisting of following :(a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520.(b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP
907Supplying, erecting, testing & commissioning of fire pump control panel (FCP) of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories, wiring & cabling along with allied accessories with following incoming and outgoings, suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply as per specificationsthe capacity of electric motor driven pump are as followsa. Main fire pump(MFP) having capacity of 22kW 1no (1 working)b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby, alternate run per start in auto mode) comprises of the following features & switchgears:1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating.2. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFU's, starters & outgoing terminals with necessary accessories like stainless steel nut bolts with spring washers for connections, mounted on required no of epoxy or porcelain support insulators of suitable ratings etc. 3. Individual pump TPN SFU having rotary handle with HRC fuses of suitable rating. 4. Digital voltmeter & ammeter & RYB indicating lamps & push buttons & SPP, O/L & phase reversal protection with emergency stop switch.5. TPN SPD 100kA Type 1 +2 tested.6. Required pressure transducer with pressure indication on panel with cabling required for monitoring & automatic operation of fire pumps.
908For main electric motor driven fire hydrant system pump of 93kW capacity & relevant capacity jockey pump add Rs…. (FIRE-A6)
909For main electric motor driven fire sprinkler system pump of 93kW capacity (1Working) & relevant capacity jockey pumps (1working+1standby, alternate run per start in auto mode, add Rs…. (FIRE-B7)
910For addition of standby main diesel engine driven fire pump (1 standby), add as follows in the basic cost of Item no 13-5-1 towards required 12/24 v battery charger and diesel engine starter along with necessary accessories, indicators etc. with necessary interlocking and updation of control logic with interlocking for operation of pumps MFP for main (1working+1standby mode) & jockey fire pumps (1working+1standby, alternate run per start in auto mode) , add Rs.......The control for diesel engine comprises of automatic/manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode indicating lamp for high/ low Lub. oil pressure, high water temp and engine on indication battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC voltmeter, and 0-20 A DC ammeter with all standard relays and accessories required for automatic operation of diesel engine with interlocking for operation of main fire pumps. (FIRE-D)
911for 5.5/ 7.5 kW centrifugal type booster pump 1no(1working) , add Rs….... (FIRE-E1)
912Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP
913Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP
914Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings complete as per specification no. FF-PP
915Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP
916Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP
917Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP
918Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system.
919Supplying and erecting 75/80 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
920Supplying and erecting 100 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
921Supplying and erecting 150 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
922Supplying and erecting 75/80 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV
923Supplying and erecting 150 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV
924Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
925Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
926Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
927Supplying and erecting 75/80 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
928Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
929Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
930Supplying and erecting 200 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
931Supplying and erecting 20 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV
932Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV
933Supplying and erecting 50 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV
934Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
935Supplying gun metal double outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
936Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV
937Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
938Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FF-FFA/NZ
939Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC
940Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete as per specification no. FF-FA/FMC
941Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT
942Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
943Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG
944Supplying and erecting brass orifice plate having 6 mm. thickness, 140 mm outer dia with required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP
945Supplying and erecting M.S./CRCA cabinet for housing Fire Brigade / SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8\\" x 6\\") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
946Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8\\"x6\\") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
947Supplying, installing, testing and commissioning remote response indicators suitable to operate on 5 - 28 V dc supply having FR Polymer ABS Housing complete as per specification no. FF-FAAS/RRI
948Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
949Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 4 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, ,IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP.
950Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FF-AFAS/SD .
951Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area's etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD.
952Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area's etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD.
953Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with \\"Break Glass\\" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.
954Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM
955Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/MM
956Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM
957Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes)
958Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.
959Supplying, erecting, testing and commissioning 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR
960Supplying, erecting, testing and commissioning 15 to 30 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC
961Supplying, erecting, testing and commissioning stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity, impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min. 7 metre shielded cable and 3 Pin Professional XLR Connector, stereo jack complete as per specification no. FF-PA/MIC
962Supplying, erecting, testing and commissioning rust free microphone table stand of chrome plating/powder coating or S.S. material, up to 500 mm height and suitable base for sturdy mechanism ensuring trouble free movement complete.
963Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC
964Supplying, erecting, testing and commissioning of 1.0 sq. mm speaker wire complete.
965Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler, 15 mm (½\\") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR.
966Supplying, erecting, testing and commissioning vane type water flow detector 100 mm dia. with 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes.
967Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
968Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps).
969Providing Round bottom fire bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook complete.
970Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete.
971Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall.
972Supplying and installing auto glow (Viewing up to 15 mtr length) fire signages in PVC/Vinyl 4/6mm thick sheet or as per sample approved by client viz fire hydrant fire hydrant fire extinguishers fire exists fire door fire hose box fire & Electrical & safety etc size 300mm* 100 mm (Rates are taken from previously sanctioned estimate D1104512022-23 Mumbai subdivision vide letter no 173/2022-23 )
973Estimate No : 4136C of 2026-2027-Providing and Erecting 630 KVA Transformer with HTOH line, 320 KVA & 250 KVA Diesel Generator set at Newly Constructed Addional District and Session Court at Chalisgaon, Tal. & Dist. Jalgaon.
974Providing and erecting 4 Pole MCCB 415V 200A rated short-circuit breaking capacity 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides with insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [5-5-2]
975Providing and erecting 4 Pole MCCB 415V 250A rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides with insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [5-5-3]
976Providing and erecting 4 Pole MCCB 415V 400A rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides with insulation withstand capacity 800V no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB [5-5-4]
977Providing and erecting 4 Pole MCCB 415V 630A rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides with insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [5-5-5]
978Supplying, installing, testing and commissioning of air circuit breaker manual fixed type non-drawout type 650V 1000A rated at 50º C without deration 12kV Impulse 4 Pole (100% Neutral Protection) 50 kA (Ics=Icu=Icw for 1s) with standard accessories with ready to close individual fault trip alarm and trip indication mechanical and electrical anti pumping soft/ hard rating plug (including hard rating plug CT) with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off-Trip indication min. 5 event and trip history on breaker display on provided iron frame as per specification no. SW-SWR/ACB [5-8-3]
979Supplying, installing, testing and commissioning of 11 kV 630A vacuum circuit breaker with internal arc compliance complete erected on provided CC foundation/MS channels/trench etc. as per specification no SW-HTS /VCB [5-9-8]
980Supplying and erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 400A [5-10-28]
981Supplying and erecting terminal spreaders suitable for 4 pole above 100A up to 250A MCCB (Set of 8) [5-11-7]
982Supplying and erecting terminal spreaders suitable for 4 pole above 250A up to 400A MCCB (Set of 8) [5-11-8]
983Supplying and erecting terminal spreaders suitable for 4 pole above 630A up to 800A MCCB (Set of 8) [5-11-10]
984Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB. [5-11-14]
985Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for above 250A up to 630A MCCB. [5-11-15]
986Supplying and erecting SS enclosure for MCCB suitable for above 250 A up to 800A MCCB. [5-11-19]
987Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes panel boards etc. including cutting bending drilling welding riveting treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. [6-1-1]
988Supplying and erecting iron work sheet metal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. [6-1-19]
989Supplying and erecting self-locking arrangement with keys in duplicate made of brass of grade 1 compliance to IS 729-1979 duly erected flush with surface of panel / cupboard [6-1-20]
990Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP-BB [6-2-11]
991Supplying and erecting dual source intelligent flush mounted panel meter three phase four wire (IPM) 415V CT/ PT site programmable class I flush mounted (96 x 96 mm) meter with voltage current frequency power factor ON hrs kWh EB and DG set metering with LED display (excluding CT'S) complete with RS 485 communication protocol class I accuracy and wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer. [6-3-10]
992Supplying, erecting, testing and commissioning of 11KV HT metering cubical (compact / vertical type) approved by MSEDCL / licensee fabricated with 2 mm (14 SWG) M.S. sheets with supporting angle painted with powder coating / epoxy paint of required shade copper bus bar size 25 x 6 mm heavy duty mechanical lock with counter meter for measuring no of times the opening of meter door top side cover (CT PT cover) interlock with meter door epoxy casted 3 nos. CT having required ratio between 10/5A to 50/5A VA10 or 15 Class 0.5S epoxy casted 3 nos. PT having ratio 11000/V3/110/V3 VA 50 Class 0.5 suitable for provided trivector meter and provision for incoming and outgoing cables complete duly tested by licensee with necessary test certificates and erected on provided plinth/ cc foundation. [6-4-1]
993Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates. [6-5-2]
994Supplying and erecting LED type indicating pilot lamp with LED colours red / yellow / green 230 / 250V on provided box / panel with necessary material wiring & connections etc. [6-5-5]
995Supplying and erecting LED type indicating pilot lamp with LED colour blue 230 / 250 V on provided box / panel with necessary material wiring & connections etc. [6-5-6]
996Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½core 240 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-23]
997Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½core 400 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-25]
998Supplying, erecting & terminating XLPE insulated galvanised steel formed wire armoured (strip) cable 11 kV(E) 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT [7-3-2]
999Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification no. CB-JT/HT [7-5-2]
1000Providing and erecting Heat shrinkable outdoor termination kit for 11 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification no. CB-JT/HT [7-5-6]
1001Supplying and erecting G.I. pipe ‘A’ class 75 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE [7-6-4]
1002Supplying and laying (including excavation) of suitable width & depth up to 90 cm) 146 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface to required depth complete. [7-6-13]
1003Supplying and erecting rolled steel joist (girder) pole 100 x 116 mm (23 kg/m) with base plate in provided foundation as per specification no. OH-PL/RSJ [8-1-13]
1004Supplying and erecting 100 x 50 x 6 mm with 4.7 mm thick web and 7.5 mm thick flange channel iron cross arm of suitable length for 2.4 m wide DP structure and erecting on DP with 50x6mm clamp complete as per specification no. OH-PL/BKT. [Req. 4m - 2.4 = 1.6m x 500 =800 + 1910 = 2710 + 5% = 2845.5] [8-3-11]
1005Supplying and erecting 100 x 50 x 6 mm with 4.7 mm thick web and 7.5 mm thick flange channel iron cross arm of suitable length for 2.4 m wide DP structure and erecting on DP with 50x6mm clamp complete as per specification no. OH-PL/BKT [8-3-11]
1006Supplying and erecting V cross arm with ISM channel of 75x40x6mm for 11kV HT OH line with arrangement to fix insulator at 45mm from the end & horizontal distance between insulators 1220mm bent at angle of 60 degree keeping base 305mm and the total vertical height of V cross arm as 460mm and fixed on pole with MS clamp of 80x10 mm nut bolts washers complete as per specification no. OH-PL/VCA [8-3-12]
1007Supplying and erecting 75x40 x6mm with 4.4mm thick web and 7.3mm thick flange channel (top pin) with clamp of suitable length so as to maintain vertical clearance of 1065mm for 11kV 1320mm for 22kV between insulators for erection of top pin insulators complete as per specification no. OH-PL/VCA [8-3-14]
1008Supplying and erecting bracket for guarding of HT OH Line made from channel iron 1600mm in length and 65x65x6mm thick erected on pole as per specification no. OH-PL/VCA [8-3-16]
1009Supplying and erecting single pole cut point channel set of for 11kV HT OH line two channel of size 100x50x6mm 1.6m long having stud angle of size 50x50x6mm 1.5m long with necessary clamps nut bolts etc. complete as per drawing. [8-3-17]
1010Supplying and erecting ACSR conductor of size 6/1-2.59 mm complete. (Weasel) (127.7 kg/km) as per specification No. OH-CON/ACSR [8-4-7]
1011Supplying and erecting porcelain disc type insulator 45KN with necessary hardware suitable for 11kV line complete as per specification no. OH-INS/DI [8-5-6]
1012Supplying and erecting porcelain pin type insulator with GI pin suitable for 11kV line complete as per specification no. OH-INS/PN [8-5-9]
1013Supplying and erecting porcelain post type insulator with nut bolts suitable for 11kV line complete as per specification no. OH-INS/PST [8-5-12]
1014Supplying and erecting distribution class 11 kV thyrite type lightening arrester with nut bolts on provided MS channel as per specification no. OH-INS/LA [8-5-15]
1015Supplying and erecting G.I. stay set for poles including loop insulators at inaccessible height with anchor plate 300x300x6 mm. straining screws G.l. stay wire 7/8 SWG G.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete. [8-6-2]
1016Supplying and fixing MS base plate 30x30x0.6cm size fixed to the pole base either by welding 12mm dia fixed at position. [8-6-15]
1017Supplying and erecting guarding lace for HT OH line with 8SWG G.l. wire to protect the HT OH line with binding wire of 20SWG G.l. wire for 75mm section on either side. [8-6-18]
1018Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-1]
1019Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP [9-1-4]
1020Supplying and erecting aluminium strip of high purity required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint with joints required as per specification no EA-EP. [9-2-1]
1021Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. [9-2-3]
1022Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete. [9-2-5]
1023Supplying, installing, testing and commissioning of 3 phase 11/0.433 kV 50 Hz. 630 kVA Mineral oil immersed and naturally cooled outdoor type Copper wound Non-sealed transformer delta/star connected additional neutral brought out on load side temperature rise should not exceed 45? by thermometer in oil and 50? by the resistance method in winding at full load rating using type A winding insulation (kraft paper) with HV tapping (with off load tap changer) off load +5 to -10 in steps of 2.5% having 7 number of tap positions with standard accessories complete with test certificate with losses below 1860 Watts at 50% load 5300 Watts at 100% load as per IS 1180 (part 1) 2014 with necessary permissions of Electrical Inspector as per specification no SS- TR-NSL. [10-1-10]
1024Supplying and erecting 11 kV outdoor type gang operated air break triple pole switch 400 A capacity with 3 post pin type insulator per phase mounted in horizontal or vertical position with necessary channels on provided cross arm with adequate length of C class G.l. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground level with necessary clamp. [10-6-2]
1025Supplying and erecting 11 kV outdoor type drop out fuse with insulator complete with fuse holders fuse barrel with metal fitting fuse element mounted on M.S. channel with working current of 15A capacity complete erected on provided cross arm. [10-6-5]
1026Supplying and erecting hard drawn copper solid wire no. 0 to 6 SWG complete erected for connections on H.T. sides. [10-6-10]
1027Supplying and erecting extra thick alkathene pipe 10 mm dia. erected to enclose bare conductor wires complete.. (use shall be restricted to H.T.) [10-6-11]
1028Supplying and erecting anti climbing devices fabricated from pole clamps of MS flat 40x5 mm with drooping spikes 15 cm. in length welded to it and erected on pole complete. [10-6-17]
1029Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG [10-6-18]
1030Supplying and erecting 50 x 50 x 6 mm angle iron as corner support 2m long fixed at the middle of the fencing frame and the other side inclined at 30 degree angle in cement concrete foundation of 15 x 15 x 40 cm complete duly painted with one coat of red oxide and two coats aluminium paint complete. [10-6-19]
1031Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class GI pipe with angle iron supports chain link wire mesh (jali) complete supported on channel iron erected in foundation and painted complete as per specification no SS-AS/DLD [10-6-20]
1032Supplying and erecting barbed wire two ply with 12 SWG ply and 12 SWG barb with a gap between two bars of 75 mm. firmly fixed on provided angle supports with necessary materials complete. (6.044 meters/kg.). [10-6-21]
1033Providing printed instruction chart for treating persons suffering from electric shock printed in English & Marathi and duly laminated complete. [10-6-22]
1034Providing pair of duly tested rubber hand gloves as per IS 47705 suitable for working up to 22 kV supply complete. [10-6-23]
1035Supplying standard first aid box with necessary antiseptic cream medicine for use on wounds due burn crepe bandage gauge bandage medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use scissors anti-septic solution etc. (All above contents shall be of standard makes) [10-6-24]
1036Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS 15652 – 2006 having 2 mm thickness up to 3.3 kV [10-6-25]
1037Supplying and fixing PVC synthetic elastomer electrically insulating mat with class C insulation conforming to IS 15652 – 2006 tested having 3mm thickness up to 33 kV [10-6-27]
1038Supplying, erecting, testing and commissioning of diesel generating set with alternator of 250 kVA output continuous rating 3 Phase 415 V 50c/s 0.8 p. f. A.C supply a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours along with standard accessories self-excited self-regulated screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 % with performance class G2 and maximum fuel consumption 42.30 Ltr/hr 75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters switchgears indicators connected with suitable wires/cables the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet sound absorbing material to restrict sound level up to 75 dB at 1.0 m provided with first filling of oil diesel not less than 425 Ltr etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG [11-1-18]
1039Supplying, erecting, testing and commissioning of diesel generating set with alternator of 320 kVA output continuous rating 3 Phase 415 V 50c/s 0.8 p. f. A.C supply a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours along with standard accessories self-excited self-regulated screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 % with performance class G2 and maximum fuel consumption 54.89 Ltr/hr 75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters switchgears indicators connected with suitable wires/cables the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet sound absorbing material to restrict sound level up to 75 dB at 1.0 m provided with first filling of oil diesel not less than 480 Ltr etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG [11-1-19]
1040Supplying, erecting, testing and commissioning of Microprocessor based Generator Control Unit (Synchronization panel) panel suitable for diesel generating set of 320 kVA capacity Three phase 415 Volts 50Hz A.C. with all standard features and safeties etc as per specification no. GEN-SYNC. [11-2-20]
1041Making trench in hard murum/Tar road having 0.9 m depth and minimum 0.3mtr width for laying provided cables of voltage range 3.3 kV to 11 kV complete as per specification No. CW-EXN-CTR [16-1-4]
1042Excavating hard murum / stone metal road by chiselling for preparing pit for poles stay or earth plates or for laying cables pipes & clearing the site by removing debris & making the site as required complete. [16-1-6]
1043Supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete. [16-2-3]
1044Making transformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick M- 10 PCC at the bottom and top and 250 mm. thick burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. External surface duly plastered by 12 mm thick including watering etc complete. [16-3-1]
1045Making cement concrete foundation including excavation (60 x 60) cm x deep 1/6 of pole length in 1 3 6 cement concrete 20 x 25 mm stone metal 45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered with necessary curing and finishing complete. (for above 9 m poles) [16-3-4]
1046Making cement concrete foundation in 1 2 4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps). [16-3-5]
1047Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1 3 6 cement concrete (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay). [16-3-6]
1048Supplying and erecting ON LOAD four pole automatic transfer switch 415V 1000A 50 Hz with enclosure flexibility of neutral connection line and load reversibility changeover with phase barriers source separator terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV UV phase sequence changing single phasing and event logging connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 . [3-1-1]
1049Estimate No : 4136D of 2026-2027-Providing and Installing 8 Passenger Lift (G+5) 2 No's, 10 Passenger Lift (G+5) 2 No's and 20 Passenger Lift ( G+5) 4 No's at Newly Constructed Addional District and Session Court at Chalisgaon, Tal. & Dist. Jalgaon.
1050Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No WG-MA/CON. [1-2-7]
1051Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-2]
1052Supplying and erecting green colour earthing with 1x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-2]
1053Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. [1-6-1]
1054Supplying and erecting modular type 3 pin 6A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-10]
1055Supplying and erecting modular type (two module) electronic step regulator for fan duly erected on provided plate and box with wiring connections complete. [1-6-23]
1056Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module duly erected. [1-6-28]
1057Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected. [1-6-30]
1058Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire modular type switch earthing and required accessories as per specification No WG-PW/SW [1-7-19]
1059Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire modular type switch earthing and required accessories as per specification No WG-PW/SW [1-7-20]
1060Wiring for plug on board with Switch socket surface/concealed type copper wiring and earthing and with modular accessories as per specification No WG-PW/CW [1-7-26]
1061Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. THD<10% p.f. >0.95 operating range of 140-260V in built surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver IP66 IK09 rated on provided PVC Block / wooden board with 3 years warranty. [2-1-15]
1062Supplying and erecting CRCA powder coated corridor/passage light LED fitting (4 feet) Max. 17W with high transitivity diffuser with system lumens output of Min. 2000 lumens min. efficacy of 120 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 4 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided PVC Block / wooden board with 3 years warranty. [2-1-17]
1063Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF [2-10-21]
1064Supplying, erecting and marking SPMCB 6A to 32A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-2]
1065Supplying, erecting and marking SPMCB 6A to 32A B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-3]
1066Supplying, erecting and marking TPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-11]
1067Supplying, erecting and marking FPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-13]
1068Supplying, erecting and marking double pole isolator only switch version of miniature circuit breaker of 40A with required wiring connections and lugs etc. in provided distribution board. [5-3-14]
1069Supplying and erecting triple pole and neutral distribution board (TPNDB) SP/TP MCBs total 4 ways /12 Poles with door 1.2mm thickness surface/flush mounted IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB [5-4-4]
1070Supplying and erecting single pole and neutral distribution board (SPNDB) with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs with door 1.2mm thickness surface / flush mounted IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB [5-4-8]
1071Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. [5-4-13]
1072Supplying, fixing, and commissioning 4 pole RCCB 40A with added immunity to avoid DC pulse tripping with 30/100/300 mA sensitivity complete as per specification no. SW-RCCB/RCCB [5-6-15]
1073Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 2 core 4 sq mm copper conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-9]
1074Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 6 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-32]
1075Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 10 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-33]
1076Supplying and erecting G.I. pipe ‘A’ class 50 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE [7-6-3]
1077Supplying, installing & testing maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete and recording the results Specification no. EA-MOBI [9-1-5]
1078Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP. [9-2-2]
1079SITC of Electric Traction Passenger Lift with · Rated capacity - 8 Passenger/544Kg · Floors - G+1 floor (2 Stops/2 Landings) · Travel - 3 to 4.2 mtrs· Location of Lift Machine - MR/MRL · Rated speed - 1.0 mps VS· Car/Landing door clear opening of 800 mm wide x 2000 mm high· Clear Car size of ......mm wide x ......mm deep x 2250mm high · Lift shaft available having clear size of ......mm wide x ......mm deep ......mm Pit depth ………mm Overhead. · Doors type - COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm thick with hairline finish with frame made from MS girders bracing of adequate size with minimum safety factor of 5 with Toe Guard Apron with necessary false ceiling with adequate LED lights blower/fan for ventilation & SS chequered plate flooring handrails mirror emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.· COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI scrolling UP/DN LED indicator & with / without attendant key switch OWD with audio-visual alarm VAS in Marathi Hindi & English with intercom system with telephone instrument in Lift car LMR & FCC/ground floor.· LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI Lift car arrival & next travel direction audio-visual indication at all landings.· Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent overvoltage over speed overheat for all devices including lift motor and travel direction protection protection for phase loss at input or output etc. various operation modes such as maintenance change direction by attendant full load bypass VIP call operation self levelling operation call cancel facility auto return to home landing fireman evacuation operation earthquake operation door open/close operation from COP etc. The system can record information for minimum 30 latest faults with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength copper wire for power & control circuit with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries.· Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0 MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup min. 90 days with min. 18” FHD TV monitor to be kept in FCC/LMR as directed by Engineer In Charge.· Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory) with Traction pulley OSG electromagnetic brakes entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves suspension wire ropes/belts of adequate size & strength.· Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners counter weight frame with necessary blocks buffers with necessary support arrangement MS pit ladder etc. erected with necessary steel work.· Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill header hole pass etc complete with plaster finish civil work for erection buffers erection of lift machinery adequate size core cuts if required & scaffolding for erecting guide rails providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General - Job includes entire procedure of obtaining all necessary erection permissions & License to Work the Lift from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. [17-1-3]
1080SITC of Electric Traction Passenger Lift with · Rated capacity - 10 Passenger/680Kg · Floors - G+1 floor (2 Stops/2 Landings) · Travel - 3 to 4.2 mtrs· Location of Lift Machine - MR/MRL · Rated speed - 1.0mps VS· Car/Landing door clear opening of 800 mm wide x 2000 mm high· Clear Car size of ......mm wide x ......mm deep x 2250mm high · Lift shaft available having clear size of ......mm wide x ......mm deep ......mm Pit depth ………mm Overhead. · Doors type - COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm thick with hairline finish with frame made from MS girders bracing of adequate size with minimum safety factor of 5 with Toe Guard Apron with necessary false ceiling with adequate LED lights blower/fan for ventilation & SS chequered plate flooring handrails mirror emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.· COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI scrolling UP/DN LED indicator & with / without attendant key switch OWD with audio-visual alarm VAS in Marathi Hindi & English with intercom system with telephone instrument in Lift car LMR & FCC/ground floor.· LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI Lift car arrival & next travel direction audio-visual indication at all landings.· Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent overvoltage over speed overheat for all devices including lift motor and travel direction protection protection for phase loss at input or output etc. various operation modes such as maintenance change direction by attendant full load bypass VIP call operation self levelling operation call cancel facility auto return to home landing fireman evacuation operation earthquake operation door open/close operation from COP etc. The system can record information for minimum 30 latest faults with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength copper wire for power & control circuit with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries.· Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min.18” FHD TV monitor to be kept in FCC/LMR as directed by Engineer In Charge.· Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory) with Traction pulley OSG electromagnetic brakes entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves suspension wire ropes/belts of adequate size & strength.· Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners counter weight frame with necessary blocks buffers with necessary support arrangement MS pit ladder etc. erected with necessary steel work.· Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill header hole pass etc complete with plaster finish civil work for erection buffers erection of lift machinery adequate size core cuts if required & scaffolding for erecting guide rails providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General - Job includes entire procedure of obtaining all necessary erection permissions & License to Work the Lift from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. [17-1-4]
1081SITC of Electric Traction Passenger cum Stretcher/Hospital Lift with · Rated capacity - 20 Passenger/1360Kg · Floors - G+1 floor (2 Stops/2 Landings) · Travel - 3 to 4.2 mtrs · Location of Lift Machine - MR/MRL· Rated speed - 1.0mps VS· Car/Landing door clear opening of 1100/1200 mm wide x 2000 mm high· Clear Car size of ......mm wide x ......mm deep x 2250mm high · Lift shaft available having clear size of ......mm wide x ......mm deep ......mm Pit depth ………mm Overhead. · Doors type - COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory)· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm thick with hairline finish with frame made from MS girders bracing of adequate size with minimum safety factor of 5 with Toe Guard Apron with necessary false ceiling with adequate LED lights blower/fan for ventilation & SS chequered plate flooring handrails mirror emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.· COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI scrolling UP/DN LED indicator & with / without attendant key switch OWD with audio-visual alarm VAS in Marathi Hindi & English with intercom system with telephone instrument in Lift car LMR & FCC/ground floor.· LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI Lift car arrival & next travel direction audio-visual indication at all landings.· Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent overvoltage over speed overheat for all devices including lift motor and travel direction protection protection for phase loss at input or output etc. various operation modes such as maintenance change direction by attendant full load bypass VIP call operation self levelling operation call cancel facility auto return to home landing fireman evacuation operation earthquake operation door open/close operation from COP etc. The system can record information for minimum 30 latest faults with real-time clock management and handheld keypad with LCD screen for view and setting of parameters The control panel duly wired with proper size & strength copper wire for power & control circuit with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries.· Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 20 FHD TV monitor to be kept in FCC/LMR as directed by Engineer In Charge.· Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory) with Traction pulley OSG electromagnetic brakes entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves suspension wire ropes/belts of adequate size & strength.· Other mechanical parts such as T section adequate size guide rails for car & counter weight with brackets fasteners counter weight frame with necessary blocks buffers with necessary support arrangement MS pit ladder etc. erected with necessary steel work.· Minor civil work such as alteration work if any necessary for erection of landing door frames and its accessories e.g. sill header hole pass etc complete with plaster finish civil work for erection buffers erection of lift machinery adequate size core cuts if required & scaffolding for erecting guide rails providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General - Job includes entire procedure of obtaining all necessary erection permissions & License to Work the Lift from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. [17-1-10]
1082For Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid (non-cladded) landing door [Two panel] this includes all necessary accessories like LOPs with UP/DN buttons-arrows-indicators extension of guide rails shaft wiring with trunking traveling cables main hoisting ropes/belts & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. (LIFT A2) [3-1-1]
1083For Lift having 1000mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel] this includes all necessary accessories like LOPs with UP/DN buttons-arrows-indicators extension of guide rails shaft wiring with trunking travelling cables main hoisting ropes/belts & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. (LIFT A4) [3-1-1]
1084Full Collective control system For Lift travelling above First floor & up to Sixth floor (LIFT B1) [3-1-1]
1085Estimate No : 4136E of 2026-2027-Supplying, Installing, Testing & Commissioning of 50 KWp Ongrid Roof top Solar system at Newly Constructed Addional District and Session Court at Chalisgaon, Tal. & Dist. Jalgaon.
1086Supplying, installing, testing and commissioning of 50 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 150 Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnecting wires / cables up to solar ON GRID inverter proper base plate canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB MCB etc. wiring up to solar Inverter in casing and capping display board sign board two distinct earthing lightning arrester liaisoning charges remote monitoring system with maintaining card / chip for 5 years including net charges for RMS System complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG. [Addon 1 Kw x 25] [4-5-6]
1087Providing and erecting 4 Pole MCCB 415V 200A rated short-circuit breaking capacity 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides with insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [5-5-2]
1088Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes panel boards etc. including cutting bending drilling welding riveting treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. [6-1-1]
1089Supplying and erecting iron work sheet metal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. [6-1-19]
1090Supplying and erecting self-locking arrangement with keys in duplicate made of brass of grade 1 compliance to IS 729-1979 duly erected flush with surface of panel / cupboard [6-1-20]
1091Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP-BB [6-2-11]
1092Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates. [6-5-2]
1093Supplying and erecting LED type indicating pilot lamp with LED colours red / yellow / green 230 / 250V on provided box / panel with necessary material wiring & connections etc. [6-5-5]
1094Supplying and erecting LED type indicating pilot lamp with LED colour blue 230 / 250 V on provided box / panel with necessary material wiring & connections etc. [6-5-6]
1095Supplying, installtion & marking of surge arrestor/ surge protection device at the sub main distribution board after the incoming breaker of type 2 tested for Imax 40 kA for three phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD [6-6-6]
1096Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 95 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-34]
1097Supplying and erecting G.I. pipe ‘A’ class 75 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE [7-6-4]
1098Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-1]
1099Supplying, installing & testing maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete and recording the results Specification no. EA-MOBI [9-1-5]
1100Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP. [9-2-2]
1101Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. [9-2-3]
1102Supplying and erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete. [9-3-1]
1103Supplying and erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. [13-15-1]
1104Making cement concrete foundation in 1 3 6 cement concrete (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). [16-3-7]
1105Estimate No : 4136F of 2026-2027-Supplying, Installing, Testing & Commissioning of CCTV Surveillance system for Newly Constructed Addional District and Session Court at Chalisgaon, Tal. & Dist. Jalgaon.
1106Supplying and laying HMS PVC conduit FRLS grade 32mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC [1-1-12]
1107Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with PVC accessories on wall /ceiling as per specification No WG-MA/CON. [1-2-4]
1108Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. [1-6-1]
1109Supplying and erecting modular type 3 pin 6A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-10]
1110Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module duly erected. [1-6-28]
1111Supplying and erecting 3m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. [1-8-21]
1112Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC [1-10-1]
1113Supplying and installing cat-6 armoured cable with ECCS tape suitable for networking as per specification No. WG-COC/NC [1-10-7]
1114Supplying, fixing, and configuring 8-ports 1 G unmanaged gigabit POE switch erected in provided rack complete. [1-11-1]
1115Supplying, fixing, and configuring 24 ports POE switch in provided rack as per specification No. WG-NWC/ENS [1-11-3]
1116Supplying, installing & testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. [1-12-1]
1117Supplying and fixing 36U floor mount server rack (Dimension-DxWxH – 800x600x1600 mm) as per specification No. WG-NAS/RAK [1-12-26]
1118Supplying, installing, testing and commissioning of 2kVA capacity online pure sine wave with backup time of ....... hrs. PWM & IGBT based UPS with 0.8 to unity output pf single phase input & 1 phase output complete with all protections as per specification no. AP-UPS [3-7-2]
1119Supplying and erecting 12V/42Ah SMF battery with battery terminal wire duly charged with 24 months warranty complete [3-8-10]
1120Supplying and erecting iron work sheet metal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. [6-1-19]
1121Supplying & erecting of High definition 4/5 Megapixel IP IR Bullet Camera with following features Image Sensor minimum 1/2.8 Progressive Scan CMOS Video Resolution minimum 2592 x 1520 Video Compression H.264 H.265 or higher at least Three individuallyconfigurable stream Frame rate minimum 25 fps at all resolutions WDR minimum 120 dB Wide Dynamic Range ONVIF profile conformantminimum IR distance 50m Lens Type 2.8/4/6 mm Lens fixed focal Field of View 2.8 mm horizontal FOV 107° vertical FOV 57° diagonal FOV 129° 4 mm horizontal FOV 86° vertical FOV 47° diagonal FOV 102° 6 mm horizontal FOV 55° vertical FOV 29° diagonal FOV 65°Lux sensitivity - minimum 0.2 Lux at color minimum 0.05 Lux at Black & White 0.0 Lux (IR) Night Vision Distance minimum IR - 50m.Camera minimum Adjustment Angles - Pan 350° Tilt 72° Rotate 350°. Power Supply Support 12VDC & PoE IP67 IK10 - Vandal Resistant.Built in micro SD/SDHC/SDXC card slot of minimum 128 GB Built in microphone. minimum Input/Output - Audio in × 1 Audio Out × 1 Alarm in × 1 Alarm Out × 1. Image Settings Rotate mode saturation brightness contrast sharpness gain white balance. Image Enhancements Day/Night-Auto (ICR)/Color/Black & White 3D Digital Noise Reduction Automatic White Balance Automatic Gain Control Backlight Compensation Highlight Compensation. [3-1-1]
1122Supplying & erecting of High definition 4/5 Megapixel IP IR Dome Camera with following features Image Sensor minimum 1/2.8 Progressive Scan CMOS Video Resolution minimum 2592 x 1520 Video Compression H.264 H.265 or higher at least Three ndividually configurable stream Frame rate minimum 25 fps at all resolutions WDR minimum 120 dB Wide Dynamic Range ONVIF profile conformantminimum IR distance 50m Lens Type 2.8/4/6 mm Lens fixed focal Field of View 2.8 mm horizontal FOV 107° vertical FOV 57° diagonal FOV 129° 4 mm horizontal FOV 86° vertical FOV 47° diagonal FOV 102° 6 mm horizontal FOV 55° vertical FOV 29° diagonal FOV 65° Lux sensitivity - minimum 0.2 Lux at color minimum 0.05 Lux at Black & White 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan 350° Tilt 72° Rotate 350°. Power Supply Support 12VDC & PoE IP67 IK10 - Vandal esistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB Built in icrophone. minimum Input/Output - Audio in × 1 Audio Out × 1 Alarm in × 1 Alarm Out × 1. Image Settings Rotate mode saturation brightness contrast sharpness gain white balance. Image Enhancements Day/Night-Auto (ICR)/Color/Black & White 3D Digital Noise eduction Automatic White Balance Automatic Gain Control BacklightCompensation ighlight Compensation. Events Privacy Masking Motion detection Scene change etection Face capture Video tampering audio exception detection Region entrance detection Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - Useraccount and password protection HTTPS IP filter IEEE 802.1X digest authentication user access log TLS1.2 AES - 256 SSH/Telnet closed FTP disabled. Protocol - DHCP UDP HTTP HTTPS NTP DNS RTP RTSP SMTP SSL/TLS TCP/IP Secure Real-Time Transport Protocol (SRTP) Bonjour SNMP and Secure shell (SSH) supported protocol. RoHS WEEE ISO-14001 and REACH compliant UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable CE FCC certified. duly erected in position on wall/ceiling/false iling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM. [3-1-1]
1123Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR interface transfer rate 6 GB/S maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+ Cameras supported up to 64 Cache (MB) 256 Load/Unload Cycle -3000000 Work Load Rating per Year 180TB MTBF 1000000 Hrs. HTTPS. RoHS UL CE certified duly erected in position in provided NVR as per specification no. CCTV-HDD [3-1-1]
1124Supplying installing testing & commissioning of 64/80 Ch Network Video Recorder (NVR) suitable connect Min. 64 IP Cameras up to 5 Megapixel Resolution with HDMI 1/VGA 1 and HDMI 2/VGA 2 outputs provided Atleast one HDMI output of 4K resolution atleast one VGA output with output up to 1920 × 1080 Support H.265 or higher H.264 MJPEG Supports Redundant Dual Power Incoming Bandwidth 320 Mbps with minimum 8 SATA Hard Disks ANR Technology 8 SATA interfaces for 8 HDDs and capacity of each HDD up to 8TB minimum 02 USB port Alarm I/O 16/4 RJ-45 10/100/ 1000 Mbps self adaptive Ethernet interface support multi brand network Cameras ONVIF conformance Multiple network monitoring Web viewer . support protocol TCP/IP DHCP DNS DDNS NTP SADP SMTP NFS iSCSI UPnP™ HTTPS. RoHS UL CE FCC certified. duly erected in provided U Rack with wiring connections tagging and programming etc. complete as per specificationss no. CCTV-NVR NON CSR [3-1-1]
1125Supplying & erecting 65 professional LED display with 1920 *1080 ( Full HD) Display suitable for 64 channel NVR and following featuresBrightness minimum 500 Cd/m2 Contrast Ratio minimum 1000 1 Viewing angle 178/178 deg. Response time maximum 8 ms Inputs HDMI VGA BNC USB Audio In Built-in speakers maximum 10 W Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle dulyerected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON NON CSR [3-1-1] Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56275529
AUTHORITY Government Departments
TENDER VALUE 102.99 Crore
LAST DATE 23-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for Construction Of Additional District & Session Court Building At Chalisgaon, Dist. Jalgaon
Basic Detail
Tender No E-TENDER NOTICE NO. 08 (B-2) FOR 2026-2027
Bidding Type Tender
Location
City Jalgaon
State Maharashtra
Key Dates
Publish Date 03 Jul 2026
Submission Date 23 Jul 2026
Open Date 24 Jul 2026
Finance
Tender Value 102.99 Crore
Tender Fee 5900
EMD 51.50 Lakhs
Exemption Not Available
Document List
0801.pdf
806df130-4d60-4445-b1d5-af76a2a6d9b1.html
BOQ_2253286.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Jul 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
pdf

0801.pdf

html

806df130-4d60-4445-b1d5-af76a2a6d9b1.html

xls

BOQ_2253286.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders