Tender For annual maintenance contract For Ac/Frp/Polymer/Metallic Sheet Roofing And Re-Roofing Works In Plantand Non-Plant Buildings 2026
Tender Value
32.35 Lakhs
Estimated cost
Bid Submission
16 Jul 2026
7 days left
EMD
50000
Bank guarantee accepted
Document Fee
2950
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kollam → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for annual maintenance contract For Ac/Frp/Polymer/Metallic Sheet Roofing And Re-Roofing Works In Plantand Non-Plant Buildings 2026
BOQ
| Sl. No. | Item Description |
| 1 | Demolishing AC/FRP/Polymer/Metallic sheets from all Heights |
| 2 | Demolish AC/FRP/PVC sheet in roofing/cladding/walling/flouvers partly or completely including removal of debris away from the site to scrap yard, all type polycoated bolts, nuts and washer, labour charges, scaffolding charges, tools, tackles etc complete at all heights and upto a lead of 500m] |
| 3 | Dismantling AC/FRP/Polymer/Metallic sheets up to 10M level |
| 4 | Dismantling existing AC/ FRP sheet/ PVC sheet carefully in roofing including ridges, hips, valleys and gutters etc., including all type polycoated bolts, nuts and washer etc; and lowering and stacking reusable material within 500 metres lead including tools & tackles, labours, scaffolding etc all.<br>Up to 10m level. |
| 5 | Dismantling AC/FRP/Polymer/Metallic sheets from 10M to 20M level |
| 6 | Dismantling existing AC/ FRP sheet/ PVC sheet carefully in roofing including ridges, hips, valleys and gutters etc., including all type polycoated bolts, nuts and washer etc; and lowering and stacking reusable material within 500 metres lead including tools & tackles, labours, scaffolding etc all from 10mtr to 20mtr level. |
| 7 | Dismantling AC/FRP/Polymer/Metallic sheets from 20M to 30M level |
| 8 | Dismantling existing AC/ FRP sheet/ PVC sheet carefully in roofing including ridges, hips, valleys and gutters etc., including all type polycoated bolts, nuts and washer etc; and lowering and stacking reusable material within 500 metres lead including tools & tackles, labours, scaffolding etc all from 20mtr to 30mtr level. |
| 9 | Dismantling AC/FRP/Polymer/Metallic sheets from 30M to 40M level |
| 10 | Dismantling existing AC/ FRP sheet/ PVC sheet carefully in roofing including ridges, hips, valleys and gutters etc., including all type polycoated bolts, nuts and washer etc; and lowering and stacking reusable material within 500 metres lead including tools & tackles, labours, scaffolding etc all from 30mtr to 40mtr level. |
| 11 | Dismantling AC/FRP/Polymer/Metallic sheets walling up to 10M level |
| 12 | "Dismantling existing AC/ FRP sheet walling carefully including removal of all type polycoated bolts, nuts and washer etc; all labour charges, scaffolding charges etc; clearing the debris away from the site to scrap yard and lowering and stacking reusable material within 500 metres lead complete. <br> For level upto 10m from GL, including tools & tackles, labours, scaffolding etc all". |
| 13 | Dismantling AC/FRP/Polymer/Metallic sheets walling from 10M to 20M level |
| 14 | "Dismantling existing AC/ FRP sheet walling carefully including removal of all type polycoated bolts, nuts and washer etc; all labour charges, scaffolding charges etc; clearing the debris away from the site to scrap yard and lowering and stacking reusable material within 500 metres lead complete. <br> For level from 10m upto 20m from GL, including tools & tackles, labours, scaffolding etc all". |
| 15 | Dismantling AC/FRP sheets walling from 20M to 30M level |
| 16 | "Dismantling existing AC/ FRP sheet walling carefully including removal of all type polycoated bolts, nuts and washer etc; all labour charges, scaffolding charges etc; clearing the debris away from the site to scrap yard and lowering and stacking reusable material within 500 metres lead complete. <br> For level from 20 to 30 from GL, including tools & tackles, labours, scaffolding etc all" |
| 17 | Dismantling AC/FRP sheets walling from 30M to 40M level |
| 18 | "Dismantling existing AC/ FRP sheet walling carefully including removal of all type polycoated bolts, nuts and washer etc; all labour charges, scaffolding charges etc; clearing the debris away from the site to scrap yard and lowering and stacking reusable material within 500 metres lead complete. <br> For level from 30m upto 40m from GL, including tools & tackles, labours, scaffolding etc all" |
| 19 | Demolishing AC/FRP/PVC valley gutters/ ridge/barge boards/ louvers at a height of 10 m from GL |
| 20 | Dismantling existing AC/ FRP/ PVC valley gutters/ Ridges/ barge boards/louvers and stacking the material within 500 m lead.For level upto 10 m from GL including tools,tackles,labours,scaffolding etc all. |
| 21 | Demolishing AC/FRP/PVC valley gutters/ ridge/barge boards/ louvers from 10M to 20M |
| 22 | Dismantling existing AC/ FRP/ PVC valley gutters/ Ridges/ barge boards/louvers and stacking the material within 500 m lead.For level from 10 m upto 20m from GL including tools,tackles,labours,scaffolding etc all. |
| 23 | Demolishing AC/FRP/PVC valley gutters/ ridge/barge boards/ louvers from 20M to 30MDemolishing AC/FRP/PVC valley gutters/ ridge/barge boards/ louvers from 20M to 30M |
| 24 | Dismantling existing AC/FRP/PVC Valley gutters/Ridges/barge boards/louvers and stacking the material within 500m lead. For level from 20m upto 30m from GL including tools, tackles, labours,scaffolding etc all. |
| 25 | Demolishing AC/FRP/PVC valley gutters/ ridge/barge boards/ louvers from 30M to 40M |
| 26 | Dismantling existing AC/ FRP/ PVC valley gutters/ Ridges/ barge boards/louvers and stacking the material within 500 m lead.For level from 30 m upto 40m from GL including tools,tackles,labours,scaffolding etc all. |
| 27 | Dismantling old plaster or skirting raking out joints and cleaning the surface upto 10M from GL |
| 28 | Dismantling old plaster or skirting raking out joints and cleaning the surface for replaster including disposal of rubbish to the dumping ground within 500 metres lead including tools & tackles, labours, scaffolding etc all. For level upto 10m from GL. |
| 29 | Dismantling old plaster or skirting raking out joints and cleaning the surface FROM 10M to 20M |
| 30 | Dismantling old plaster or skirting raking out joints and cleaning the surface for replaster including disposal of rubbish to the dumping ground within 500 metres lead including tools & tackles, labours, scaffolding etc all. For level from 10m upto 20m from GL. |
| 31 | Dismantling old plaster or skirting raking out joints and cleaning the surface FROM 20M to 30M |
| 32 | Dismantling old plaster or skirting raking out joints and cleaning the surface for replaster including disposal of rubbish to the dumping ground within 500 metres lead including tools & tackles, labours, scaffolding etc all. For level from 20m upto 30m frrom GL. |
| 33 | Dismantling old plaster or skirting raking out joints and cleaning the surface FROM 30M to 40M |
| 34 | Dismantling old plaster or skirting raking out joints and cleaning the surface for replaster including disposal of rubbish to the dumping ground within 500 metres lead including tools & tackles, labours, scaffolding etc all. For level from 30m upto 40m frrom GL. |
| 35 | Dismantling and removing existing damages tar felt over roofing area for level upto 10M from GL |
| 36 | Dismantling and removing existing damaged tar felt over the roofing area and cleaning the surface neatly and dispode the waste within 500 metres within lead and supply and apply tar felt with roofing compounds on sides, surroundings of structural column supports as per the specifications directed by the company representatives and ensure leak proof including cost and conveyance of all materials, all labour charges, scaffolding charges etc. complete. For level upto 10m from GL. |
| 37 | Dismantling and removing existing damages tar felt over roofing area for level from 10M to 20M |
| 38 | Dismantling and removing existing damaged tar felt over the roofing area and cleaning the surface neatly and dispode the waste within 500 metres within lead and supply and apply tar felt with roofing compounds on sides, surroundings of structural column supports as per the specifications directed by the company representatives and ensure leak proof including cost and conveyance of all materials, all labour charges, scaffolding charges etc. complete. For level from 10m to 20mtr. |
| 39 | Dismantling and removing existing damages tar felt over roofing area for level from 20M to 30M |
| 40 | Dismantling and removing existing damaged tar felt over the roofing area and cleaning the surface neatly and dispode the waste within 500 metres within lead and supply and apply tar felt with roofing compounds on sides, surroundings of structural column supports as per the specifications directed by the company representatives and ensure leak proof including cost and conveyance of all materials, all labour charges, scaffolding charges etc. complete. For level from 20m to 30mtr. |
| 41 | Dismantling and removing existing damages tar felt over roofing area for level from 30M to 40M |
| 42 | Dismantling and removing existing damaged tar felt over the roofing area and cleaning the surface neatly and dispode the waste within 500 metres within lead and supply and apply tar felt with roofing compounds on sides, surroundings of structural column supports as per the specifications directed by the company representatives and ensure leak proof including cost and conveyance of all materials, all labour charges, scaffolding charges etc. complete. For level from 30m to 40mtr. |
| 43 | Fixing asbetos corrugated sheets (NEW/OLD) upto 10M from GL |
| 44 | "Fixing asbestos corrugated sheets (New/Old) upto any pitch in horizontal/ vertical/ curved surfaces with polymer coated J, or L hooks, bolts and nuts 8mm dia. G.I. plain and bitumen washers etc. complete (excluding the cost of purlins,rafters and trusses. The required sheet and fixtures shall be supplied by the company) including shifting, lifting, cutting sheets to size and shape wherever required all tools, tackles, labours, scaffolding etc. For level upto 10m from GL. |
| 45 | Fixing asbetos corrugated sheets (NEW/OLD) from 10M to 20M |
| 46 | "Fixing asbestos corrugated sheets (New/Old) upto any pitch in horizontal/ vertical/ curved surfaces with polymer coated J, or L hooks, bolts and nuts 8mm dia. G.I. plain and bitumen washers etc. complete (excluding the cost of purlins,rafters and trusses. The required sheet and fixtures shall be supplied by the company) including shifting, lifting, cutting sheets to size and shape wherever required all tools, tackles, labours, scaffolding etc. For level from 10m to 20mtr. |
| 47 | Fixing asbetos corrugated sheets (NEW/OLD) from 20M to 30M |
| 48 | "Fixing asbestos corrugated sheets (New/Old) upto any pitch in horizontal/ vertical/ curved surfaces with polymer coated J, or L hooks, bolts and nuts 8mm dia. G.I. plain and bitumen washers etc. complete (excluding the cost of purlins,rafters and trusses. The required sheet and fixtures shall be supplied by the company) including shifting, lifting, cutting sheets to size and shape wherever required all tools, tackles, labours, scaffolding etc. For level from 20m to 30mtr. |
| 49 | Fixing asbetos corrugated sheets (NEW/OLD) from 30M to 40M |
| 50 | "Fixing asbestos corrugated sheets (New/Old) upto any pitch in horizontal/ vertical/ curved surfaces with polymer coated J, or L hooks, bolts and nuts 8mm dia. G.I. plain and bitumen washers etc. complete (excluding the cost of purlins,rafters and trusses. The required sheet and fixtures shall be supplied by the company) including shifting, lifting, cutting sheets to size and shape wherever required all tools, tackles, labours, scaffolding etc. For level from 30m to 40mtr. |
| 51 | Fixing FRP/Poly carbonate/PVC/Metallic sheet up to 10M from GL |
| 52 | "Fixing FRP/poly carbonate/PVC /metallic sheets upto any pitch in horizontal /vertical / curved surfaces and fixing with polymer coated J, or L hooks, bolts and nuts 8mm dia. G.I. plain and bitumen washers or sheets shall be fixed using self drilling / self tapping screw of size (5.5X55mm) with EPDM seal complete , but excluding the cost of purlins, rafters, trusses, and including cutting to size and shapes where ever required. etc. complete (excluding cost of sheet, purlins, rafters and trusses.The required sheet and fixtures shall be supplied by the company), including shifting, lifting,cutting sheets to size and shape wherever required,all tools,tackles, labours, scaffolding etc. For level upto 10m from GL" |
| 53 | Fixing FRP/Poly carbonate/PVC/Metallic sheet from 10M to 20M |
| 54 | "Fixing FRP/poly carbonate/PVC/metallic sheets upto any pitch in horizontal /vertical / curved surfaces and fixing with polymer coated J, or L hooks, bolts and nuts 8mm dia. G.I. plain and bitumen washers or sheets shall be fixed using self drilling / self tapping screw of size (5.5X55mm) with EPDM seal complete , but excluding the cost of purlins, rafters, trusses, and including cutting to size and shapes where ever required. etc. complete (excluding cost of sheet, purlins, rafters and trusses.The required sheet and fixtures shall be supplied by the company), including shifting, lifting,cutting sheets to size and shape wherever required,all tools,tackles, labours, scaffolding etc. For level from 10mtr to 20mtr. |
| 55 | Fixing FRP/Poly carbonate/PVC/Metallic sheet from 20M to 30M |
| 56 | "Fixing FRP/poly carbonate/PVC /metallic sheets upto any pitch in horizontal /vertical / curved surfaces and fixing with polymer coated J, or L hooks, bolts and nuts 8mm dia. G.I. plain and bitumen washers or sheets shall be fixed using self drilling / self tapping screw of size (5.5X55mm) with EPDM seal complete , but excluding the cost of purlins, rafters, trusses, and including cutting to size and shapes where ever required. etc. complete (excluding cost of sheet, purlins, rafters and trusses.The required sheet and fixtures shall be supplied by the company), including shifting, lifting,cutting sheets to size and shape wherever required,all tools,tackles, labours, scaffolding etc. For level from 20mtr to 30mtr. |
| 57 | Fixing FRP/Poly carbonate/PVC/Metallic sheet from 30M to 40M |
| 58 | "Fixing FRP/poly carbonate/PVC /metallic sheets upto any pitch in horizontal /vertical / curved surfaces and fixing with polymer coated J, or L hooks, bolts and nuts 8mm dia. G.I. plain and bitumen washers or sheets shall be fixed using self drilling / self tapping screw of size (5.5X55mm) with EPDM seal complete , but excluding the cost of purlins, rafters, trusses, and including cutting to size and shapes where ever required. etc. complete (excluding cost of sheet, purlins, rafters and trusses.The required sheet and fixtures shall be supplied by the company), including shifting, lifting,cutting sheets to size and shape wherever required,all tools,tackles, labours, scaffolding etc. For level from 30mtr to 40mtr. |
| 59 | Fixing AC/FRP/Poly carbonate/PVC/Metallic ridges up to 10M from GL |
| 60 | "Fixing AC/FRP/PVC/metallic ridges and hips AC/FRP/PVC/metallic valleys and barges fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers including shifting,lifting,tools & tackles, labours, scaffolding etc in roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc.(excluding the cost of sheet, purlins, rafters and trusses.The required sheet and fixtures shall be supplied by the company) Corrugated serrated adjustable ridges including shifting, lifting,cutting sheets to size and shape wherever required,all tools,tackles, labours, scaffolding etc. Level upto 10 m" |
| 61 | Fixing AC/FRP/Poly carbonate/PVC/Metallic ridges from 10M to 20M |
| 62 | "Fixing AC/FRP/PVC/metallic ridges and hips AC/FRP/PVC/metallic valleys and barges fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers including shifting,lifting,tools & tackles, labours, scaffolding etc in roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc.(excluding the cost of sheet, purlins, rafters and trusses.The required sheet and fixtures shall be supplied by the company) Corrugated serrated adjustable ridges, including shifting, lifting,cutting sheets to size and shape wherever required,all tools,tackles, labours, scaffolding etc. For level from 10mtr to 20mtr |
| 63 | Fixing AC/FRP/Poly carbonate/PVC/Metallic ridges from 20M to 30M |
| 64 | "Fixing AC/FRP/PVC/metallic ridges and hips AC/FRP/PVC/metallic valleys and barges fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers including shifting,lifting,tools & tackles, labours, scaffolding etc in roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc.(excluding the cost of sheet, purlins, rafters and trusses.The required sheet and fixtures shall be supplied by the company) Corrugated serrated adjustable ridges, including shifting, lifting,cutting sheets to size and shape wherever required,all tools,tackles, labours, scaffolding etc. For level from 20mtr to 30mtr |
| 65 | Fixing AC/FRP/Poly carbonate/PVC/Metallic ridges from 30M to 40M |
| 66 | Fixing AC/FRP/PVC/metallic ridges and hips AC/FRP/PVC/metallic valleys and barges fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers including shifting,lifting,tools & tackles, labours, scaffolding etc in roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc.(excluding the cost of sheet, purlins, rafters and trusses.The required sheet and fixtures shall be supplied by the company) Corrugated serrated adjustable ridges, including shifting, lifting,cutting sheets to size and shape wherever required,all tools,tackles, labours, scaffolding etc. For level from 30mtr to 40mtr |
| 67 | Replacing the damaged L/J bolts, polycoated bolts of AC/FRP sheet roofing up to 10M from GL |
| 68 | "Replacing the damaged L/J bolts , polycoated bolts of AC / FRP sheet roofing, side cladding ridges, barge board with new special type polycoated bolts, nuts,washers ctc. After rearranging the required overlap as per the instruction of the company representatives and collecting reusable poly coated bolts including all labour charges, scaffolding charges etc.complete (excluding cost of special type poly coated bolts, nuts washers etc.)including tools & tackles, labours, scaffolding etc all. For level upto 10m from GL" |
| 69 | Replacing the damaged L/J bolts, polycoated bolts of AC/FRP sheet roofing FROM 10M to 20M |
| 70 | "Replacing the damaged L/J bolts , polycoated bolts of AC / FRP sheet roofing, side cladding ridges, barge board with new special type polycoated bolts, nuts,washers ctc. After rearranging the required overlap as per the instruction of the company representatives and collecting reusable poly coated bolts including all labour charges, scaffolding charges etc.complete (excluding cost of special type poly coated bolts, nuts washers etc.)including tools & tackles, labours, scaffolding etc all. For level from 10mtr 20mtr" |
| 71 | Replacing the damaged L/J bolts, polycoated bolts of AC/FRP sheet roofing FROM 20M to 30M |
| 72 | "Replacing the damaged L/J bolts , polycoated bolts of AC / FRP sheet roofing, side cladding ridges, barge board with new special type polycoated bolts, nuts,washers ctc. After rearranging the required overlap as per the instruction of the company representatives and collecting reusable poly coated bolts including all labour charges, scaffolding charges etc.complete (excluding cost of special type poly coated bolts, nuts washers etc.)including tools & tackles, labours, scaffolding etc all. For level from 20mtr 30mtr" |
| 73 | Replacing the damaged L/J bolts, polycoated bolts of AC/FRP sheet roofing FROM 30M to 40M |
| 74 | "Replacing the damaged L/J bolts , polycoated bolts of AC / FRP sheet roofing, side cladding ridges, barge board with new special type polycoated bolts, nuts,washers ctc. After rearranging the required overlap as per the instruction of the company representatives and collecting reusable poly coated bolts including all labour charges, scaffolding charges etc.complete (excluding cost of special type poly coated bolts, nuts washers etc.)including tools & tackles, labours, scaffolding etc all. For level from 30mtr 40mtr" |
| 75 | Plastering the side of surrounding structural column support or edge between AC sheet with masonry wall up to 10M from GL |
| 76 | Plastering the sides of sorrounding structural column support or edge between AC sheet with masonry wall with 12 mm cement plaster of mix. 1:3 (1 cement : 3 fine sand). including tools & tackles, labours, scaffolding etc all. For level upto 10m from GL(Cement shall be supplied by the company) |
| 77 | Plastering the side of surrounding structural column support or edge between AC sheet with masonry wall from 10M to 20M |
| 78 | Plastering the sides of sorrounding structural column support or edge between AC sheet with masonry wall with 12 mm cement plaster of mix. 1:3 (1 cement : 3 fine sand). including tools & tackles, labours, scaffolding etc all. For level from 10m to 20mtr(Cement shall be supplied by the company) |
| 79 | Plastering the side of surrounding structural column support or edge between AC sheet with masonry wall from 20M to 30M |
| 80 | Plastering the sides of sorrounding structural column support or edge between AC sheet with masonry wall with 12 mm cement plaster of mix. 1:3 (1 cement : 3 fine sand). including tools & tackles, labours, scaffolding etc all. For level from 20m to 30mtr(Cement shall be supplied by the company) |
| 81 | Plastering the side of surrounding structural column support or edge between AC sheet with masonry wall from 30M to 40M |
| 82 | Plastering the sides of sorrounding structural column support or edge between AC sheet with masonry wall with 12 mm cement plaster of mix. 1:3 (1 cement : 3 fine sand). including tools & tackles, labours, scaffolding etc all. For level from 30m to 40mtr(Cement shall be supplied by the company) |
| 83 | Clearing way disposal over roofs at different level including disposal of debris up to 10M from GL |
| 84 | 'Clearing away disposal over roofs at different levels including disposal of debris within 500m including tools & tackles, labours, scaffolding etc all. For level upto 10m from GL |
| 85 | Clearing way disposal over roofs at different level including disposal of debris from 10M to 20M |
| 86 | 'Clearing away disposal over roofs at different levels including disposal of debris within 500m including tools & tackles, labours, scaffolding etc all. For level upto 20m from 10m level |
| 87 | Clearing way disposal over roofs at different level including disposal of debris from 20M to 30M |
| 88 | 'Clearing away disposal over roofs at different levels including disposal of debris within 500m including tools & tackles, labours, scaffolding etc all. For level upto 30m from 20m level |
| 89 | Clearing way disposal over roofs at different level including disposal of debris from 30M to 40M |
| 90 | 'Clearing away disposal over roofs at different levels including disposal of debris within 500m including tools & tackles, labours, scaffolding etc all. For level upto 40m from 30m level |
| 91 | Fixing AC/FRP louvers up to 10M from GL |
| 92 | "Fixing FRP louvers fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 1.60 mm thick with zinc coating not less than 350 gm/ m2, including shifting,lifting, tools & tackles, labours, scaffolding etc all.(excluding the cost of sheet, purlins, rafters and trusses,the required sheet and fixtures shall be supplied by the company) For level upto 10m from GL" |
| 93 | Fixing AC/FRP louvers from 10M to 20M |
| 94 | Fixing FRP louvers fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 1.60 mm thick with zinc coating not less than 350 gm/ m2, including shifting,lifting, tools & tackles, labours, scaffolding etc all.(excluding the cost of sheet, purlins, rafters and trusses,the required sheet and fixtures shall be supplied by the company) For level from 10mtr to 20mtr |
| 95 | Fixing AC/FRP louvers from 20M to 30M |
| 96 | "Fixing AC/FRP louvers fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 1.60 mm thick with zinc coating not less than 350 gm/ m2, including shifting,lifting, tools & tackles, labours, scaffolding etc all.(excluding the cost of sheet, purlins, rafters and trusses,the required sheet and fixtures shall be supplied by the company) For level from 20m to 30m" |
| 97 | Fixing AC/FRP louvers from 30M to 40M |
| 98 | Fixing FRP louvers fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 1.60 mm thick with zinc coating not less than 350 gm/ m2, including shifting,lifting, tools & tackles, labours, scaffolding etc all.(excluding the cost of sheet, purlins, rafters and trusses,the required sheet and fixtures shall be supplied by the company) For level from 30m to 40m" |
| 99 | Clearing disposal over valley gutter up to 10M from GL |
| 100 | Clearing away the deposit over the valley gutters at all levels including disposal of debris within 500m level upto 10m |
| 101 | Clearing disposal over valley gutter from 10M to 20M |
| 102 | Clearing away the deposit over the valley gutters at all levels including disposal of debris within 500m level upto 20m from 10m |
| 103 | Clearing disposal over valley gutter from 20M to 30M |
| 104 | Clearing away the deposit over the valley gutters at all levels including disposal of debris within 500m level up To 20m from 30m |
| 105 | Clearing disposal over valley gutter from 30M to 40M |
| 106 | Clearing away the deposit over the valley gutters at all levels including disposal of debris within 500m level upto40m from 30m |
| 107 | Extra for circular cut in AC sheet |
| 108 | Extra for circular cutting inAC/FRP corraguated sheet roofing for making opening for any height for making openings of area exceeding 40 square decimeter |
| 109 | Supply and apply tar felt with roofing compounds on sides, surroundings of structural column supports up to 10M from GL |
| 110 | Supply and applying tar felt with roofing compounds on sides,surroundings of structural column support after surface peraparation as per the specification directed by the company reprsentatives and ensure leak proof including cost and conveyance of all materials,all labour charges,scaffolding charges etc.complete for level upto 10m from gl |
| 111 | Supply and apply tar felt with roofing compounds on sides, surroundings of structural column supports from 10M to 20M |
| 112 | Supply and applying tar felt with roofing compounds on sides,surroundings of structural column support after surface peraparation as per the specification directed by the company reprsentatives and ensure leak proof including cost and conveyance of all materials,all labour charges,scaffolding charges etc.complete for level from 10m to 20m |
| 113 | Supply and apply tar felt with roofing compounds on sides, surroundings of structural column supports from 20M to 30M |
| 114 | Supply and applying tar felt with roofing compounds on sides,surroundings of structural column support after surface peraparation as per the specification directed by the company reprsentatives and ensure leak proof including cost and conveyance of all materials,all labour charges,scaffolding charges etc.complete for level from 20m to 30m |
| 115 | Supply and apply tar felt with roofing compounds on sides, surroundings of structural column supports from 30M to 40M |
| 116 | Supply and applying tar felt with roofing compounds on sides,surroundings of structural column support after surface peraparation as per the specification directed by the company reprsentatives and ensure leak proof including cost and conveyance of all materials,all labour charges,scaffolding charges etc.complete for level from 30m to 40m Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 02, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 16, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysJul 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender