Tender For General-Rewiring Room No 610 Conference Hall In Niyamasabha Building -Providing Electrical Installation, Light Fittings And Necessary Plugs In Connection With Civil Renovation Work-General Electrical Work
Tender Value
Ref. Documents
Estimated cost
Bid Submission
08 Jul 2026
3 days left
EMD
6943
Bank guarantee accepted
Document Fee
615
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvananthapuram → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for General-Rewiring Room No 610 Conference Hall In Niyamasabha Building -Providing Electrical Installation, Light Fittings And Necessary Plugs In Connection With Civil Renovation Work-General Electrical Work
BOQ
| Sl. No. | Item Description |
| 1 | Electrical Work |
| 2 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 3 | 1.55.2:Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B |
| 4 | OD71920/2025-2026:Supply Installation Testing and Commissioning of 1800 lumen round/ square(1X1) recessed fitting made of diecast aluminium, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea |
| 5 | OD83395/2025-2026:Supply and fixing of 10W 90 degree angular connecting Linear suspended lights withmin 115 lumen per watt system efficacy and minimum 1150 system lumens highefficiency long life linear suspended luminaire with white powder coated finishextruded aluminium housing with suspension kit included in packaging, special HETplastic diffuser, LED driver duly wired up to terminal block for easy installation andlong service, CRI>80, IP20, driver efficiency >85%, THD<10%,CCT5700K, pf>0.95, surge protection 3kv (Wipro make Axeon+angular LEDsuspended LM34-930-90L57WG2L or equivalent) |
| 6 | OD83397/2025-2026:Supply and fixing of 20W 4feet Linear suspended lights with min 115 lumen per wattsystem efficacy and minimum 2300 system lumens high efficiency long life linearsuspended luminaire with white powder coated finish extruded aluminium housingwith suspension kit included in packaging, special HET plastic diffuser, LED driverduly wired up to terminal block for easy installation and long service, CRI>80,IP20, driver efficiency >85%, THD0.95, surgeprotection 3kv (Wipro make Axeon LED suspended 4ft LM34-251-XXX57WG2L orequivalent) |
| 7 | OD83398/2025-2026:Supply and fixing of 30W 6feet Linear suspended lights with min 115 lumen per watt system efficacy and minimum 3450 system lumens high efficiency long life linear suspended luminaire with white powder coated finish extruded aluminium housing with suspension kit included in packaging, special HET plastic diffuser, LED driver duly wired up to terminal block for easy installation and long service, CRI>80, IP20, driver efficiency >85%, THD<10%,CCT 5700K, pf>0.95, surge protection 3kv (Wipro make Axeon LED suspended 6ft LM34-411-XXX57WG2L or equivalent) |
| 8 | OD72228/2026-2027:Supply and fixing 3600 lumen square (2ft X 2ft) recessed fitting made of crca sheet of thickness 0.5mm, having efficacy not less than 100l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea complete with all accessories and fluorescent lamps etc. suspended from ceiling using 4 nos steel chain (16 SWG or nearest) of length not exceeding 30 cm properly hooked to steel hooks anchored to the ceiling and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required. (Philips FullGlow / Crompton POLARIS NIO / Wipro Immaculate or equivalent) |
| 9 | OD42876/2025-2026:Supply and fixing LED Cove light of 5m length, Uniform brightness with 2150 lumens, (NW colour) with suitable drive ( LED strip SKY Cove 5M NW with driver Equivalent ,make Philips or equivalent) |
| 10 | 1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 11 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 12 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 13 | OD41730/2025-2026:Supply and fixing of following sizes of Corrugated PVC flexible conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required 20 mm |
| 14 | OD99872/2025-2026:Supplying and fixing of following sizes of medium class PVC Casing Capping along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 15 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 16 | 1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm |
| 17 | 1.17.9:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 1.5 sq. mm |
| 18 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 19 | 1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 20 | 90.10.1.5:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface |
| 21 | 1.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module |
| 22 | 1.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module |
| 23 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 24 | 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 25 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 26 | 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 27 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 28 | OD41731/2025-2026:Dismantling the existing Electrical Installation(Ceiling fan, light fittings etc.) from work site and conveyance to section store without any further damages. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 02, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysJul 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer