Tender For Others-Mla Adf-Cwss To Oachira And Adjoining Panchayath-General Civil Work-Construction Of New Tube Well At Ward No.13 In Clappana Panchayath
Tender Value
18.70 Lakhs
Estimated cost
Bid Submission
10 Jul 2026
5 days left
EMD
46770
Bank guarantee accepted
Document Fee
2760
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kollam → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Others-Mla Adf-Cwss To Oachira And Adjoining Panchayath-General Civil Work-Construction Of New Tube Well At Ward No.13 In Clappana Panchayath
BOQ
| Sl. No. | Item Description |
| 1 | Construction of tube well and pump house |
| 2 | OD237380/2024-2025:Boring /drilling bore well of required dia for casing / strainer pipe, by suitable methodprescribed in IS: 2800 ( part I), including collecting samples from different strata, preparing and submitting stratachart/ bore, including hire & running charges of all equipments, tools, plants & machineries required for the job, allcomplete as per direction of Engineer- in- charge, beyond 150 metre & upto 200 metre depth below groundlevel.<br>Rocky strata including Boulders<br>400 mm dia |
| 3 | OD237371/2024-2025:Supplying, assembling, lowering and fixing in vertical position in bore well ERW ( Electric ResistanceWelded ) FE 410 mild steel screwed and socketed / plain ended casing pipes or required dia , conformingto IS 4270, of reputed & approved make, including painted with outside surface with two coats ofanticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings& accessories, all complete, forall depths, as per direction of Engineer-in-Charge.450 mmnominal size dia having minimum wall thickness 8 mm |
| 4 | 23.15.3:Providing and fixing Bail plug / Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS : 2800 (part I).200 mm dia |
| 5 | 23.3.3:Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS : 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer- in- Charge.200 mm nominal size dia |
| 6 | 23.4.3:Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer - in-charge200 mm nominal size dia |
| 7 | 23.13.3:Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:200 mm dia |
| 8 | OD237360/2024-2025:Supplying, Conveying and stacking at site for taking measurement best quality round pebbles, whichshould pass through 10 mm sieve and should retain in 5 mm sieve as per relevant IS Specification andpacking round the strainer pipe using pebble for graded size as directed by the department officers andback washing including all labour charges cost and conveyance of water etc,complete. |
| 9 | OD237377/2024-2025:Clay packing around the well for perfect clay sealing using saddle clay including conveyance cost of all materials and labour charges etc complete |
| 10 | 23.12:Development of tube well in accordance with IS: 2800 (Part I) and IS : 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \\"V\\" notch method or any other approved method, measuring static level & draw down etc.by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer - in-charge. |
| 11 | 4.2.3:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 12 | OD237378/2024-2025:Providing and fixing M.S. clamp of required dia to the top of casing / housing pipe of tubewell as per IS :2800 ( part I), including necessary bolts & nuts of required size complete.200 mm clamp |
| 13 | OD237375/2024-2025:Supplying, stacking and filling good earth at site. |
| 14 | OD237366/2024-2025:Providing and fixing 25 mm G.I. pipe as pole for supporting cable including trenching, installing the pole of 3.5 m length with concreting for base of size 30x30x30 cm, tie the cable with pole, refilling etc. complete as per the direction of departmental officers. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 02, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysJul 13, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender