Tender For Stabilization Of 33 Kv Ramnagar-Basantgarh Line By Way Of Insertion Of Poles In Longer Span And Shifting Of 33 Kv Line From The Sliding Zone,Extension Of Control Room Building Of 33/11 Kv R/Stn Ramnagar,Stablisation Of 33 Kv Chenani - Dhun
Tender Overview
Project Description
Tender for Stabilization Of 33 Kv Ramnagar-Basantgarh Line By Way Of Insertion Of Poles In Longer Span And Shifting Of 33 Kv Line From The Sliding Zone,Extension Of Control Room Building Of 33/11 Kv R/Stn Ramnagar,Stablisation Of 33 Kv Chenani - Dhuna Line By Way Of Insertion Of Poles In Longer Span And Replacement Of Damage Poles And Proposal For Creation Of Line Way At 04 Nos R/Stn Battal,Jib,Johnu And Pathi Etc. And Provision Of 33 Kv Vcbs,11 Kv Xlpe Cables,11 Kv Isolators,11 Kv Vcb,C&R Panels,33 Kv Ct,33 Kv Pts In Respect Of Sub Division Udh Ur Scheme Code : Pddss267100645important Note : All Allied And Associated Works Required For Successful Execution Of Above Items Of Works Including Testing And Energisation , Specifically Mentioned Or Not In Above Description But Required At Site Shall Be Deemed To Be Included And Covered In The Quoted Rates.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 08-Jul-2026 | PaymentTermsandcompletion | Other | 24-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Survey, Supply, Installation , Testing and Commissioning for 33 kV LINE BAY (LILO) at 33/11 KV Receiving Station Battal,Johnu,Jib and Pathi including installation of clamps of sorts and other allied petty material which ever is required at site |
| 2 | 33 kV Vacuum Circuit Breaker (36 kV, 1250A, 26.2 kA, Outdoor Type) SCADA compatible Make Megawin, BHEL,Pascal or Stelmac |
| 3 | 33kv Isolator with Earthing Blade (36kv , 1250A,outdoor,3 poles, 25KA ). |
| 4 | 33kv Isolator without Earthing Blade (36kv , 1250A,outdoor,3 poles, 25KA ). |
| 5 | 30 kv Lightening arrestors (30kv,10KA, Polymer, station class, ZnO)gap less for R/Stn Battal and Chowki |
| 6 | 33 kV C&R Panel along with O/C, E/F and differential relays (IEC61850), mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port SCADA Compatible.Make Make Megawin, BHEL,Pascal or Stelmac |
| 7 | 33 KV Potential transformer(33KV/110 V, 1 phase, multicore, outdoor)1 no per phase |
| 8 | 33 KV Current transformer(33KV, 1 phase,multi ratio,multicore, outdoor)1 no per phase |
| 9 | 33 kV Post Insulator Polymer 36kV,235kV Impulse, creepage distance 1224m station type |
| 10 | CONTROL CABLES : i) 12 Core 2.5mm2 multistrand control cable copper armoured, 1.1KV Grade ISI,FRLS of make Havells, Polycab,etc. a |
| 11 | ii) 4 Core 2.5mm2 multistrand control cable copper armoured, 1.1KV Grade ISI,FRLS of make Havells, Polycab,etc. |
| 12 | iii) 2 Core 2.5mm2 control multistrand cable copper armoured, 1.1KV Grade ISI,FRLS of make Havells, Polycab,etc. |
| 13 | Galvanised Steel Structure |
| 14 | Galvanised Nuts & Bolts |
| 15 | 33 KV Equipment foundation for 33KV VCBs ,33 KV CT,33 KV isolators,33 KV PTs ,33 KV LA at R/Stn Battal,Johnu,Jib and Pathi as per REC standard |
| 16 | Providing & Fixing of of BusBar System with 200 sqmm A.C.S.R.Panther Conductor,including Aluminium tension/suspension fitting suitable for Panther Conductor,T Clamps/P.G.Clamps/P.I. Clamps./C.T. Clamps/Isolator Clamps/PT Clamps etc complete job |
| 17 | Survey, Supply, Installation , Testing and Commissioning for Stablisation of 33 KV Ramnagar-Basantgarh Line by way of insertion of poles in longer span and shifting of 33 KV line from the sliding zone at different locations. |
| 18 | Supply, Transportation, Erection of 11 Mtr Long ST Poles (ST410-SP56) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. |
| 19 | GI Channel iron X-arm of size 100*50*6 and GI angle iron brace of size 65*65*6 mm of different sorts including clamps,Ties and braces for multi pole structures |
| 20 | 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm |
| 21 | 33kV Polymeric composite Disc Insulator with fitting 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm |
| 22 | PG clamps for 150 mm2 ACSR Conductor |
| 23 | Galvinized Nuts and Bolts |
| 24 | Danger Plates with Clamps |
| 25 | Anti-Climbing Device with Clamps |
| 26 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5mtr long through GI Strip. |
| 27 | Painting of Poles with Red Oxide and aluminium paint (min 2 coats each) |
| 28 | Cement bottoming 1:2:4 mix as per REC standards .6cum/pole (to be done during erection of poles) |
| 29 | Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete |
| 30 | 100 mm2 ACSR conductor |
| 31 | Guard netting |
| 32 | Creation of Isolation points along the line by way of 33 KV Isolators without earthing blades on Double Pole structure ST 11 Mtr Poles and MS Steel etc. Complete job. |
| 33 | Survey, Supply, Installation , Testing and Commissioning for Stablisation of 33 KV Chenani-Dhuna Line by way of insertion of poles in longer span and shifting of 33 KV line from the sliding zone at different locations. |
| 34 | Supply, Transportation, Erection of 11 Mtr Long ST Poles (ST410-SP56) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. |
| 35 | GI Channel iron X-arm of size 100*50*6 and GI angle iron brace of size 65*65*6 mm of different sorts including clamps,Ties and braces for multi pole structures |
| 36 | 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm |
| 37 | 33kV Polymeric composite Disc Insulator with fitting 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm |
| 38 | PG clamps for 150 mm2 ACSR Conductor |
| 39 | Galvinized Nuts and Bolts |
| 40 | Danger Plates with Clamps |
| 41 | Anti-Climbing Device with Clamps |
| 42 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5mtr long through GI Strip. |
| 43 | Painting of Poles with Red Oxide and aluminium paint (min 2 coats each) |
| 44 | Cement bottoming 1:2:4 mix as per REC standards .6cum/pole (to be done during erection of poles) |
| 45 | Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete |
| 46 | 100 mm2 ACSR conductor |
| 47 | Guard netting |
| 48 | Creation of Isolation points along the line by way of 33 KV Isolators without earthing blades on Double pole structure ST 11 Mtr Poles and MS Steel etc. Complete job. |
| 49 | Common Miscellaneous Equipments For R/stns in respect of STD Sub Division Udhampur JPDCL |
| 50 | Supply, Errection, Testing & commisioning of Battery Bank 32v 100AH of 15+1 No. cells of 2V each, sealed maintenance free VRLA type, Hgh Impact Polyprophelene copolymer container flame retardant of make Exide Amaron or Tata etc. |
| 51 | Supply, Errection, Testing & commisioning of Float-Cum-boost Charger with full wave rectification for 220v, 1 Phase 50HZ AC input supply suitable for charging of Battery Bank 32V, 100AH of 15+1 No. cells of 2V each, sealed maintenance free VRLA type, Hgh Impact Polyprophelene copolymer container flame retardant. |
| 52 | Distribution Panel (30 V, DC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43 for 2 No battery incoming supply with 2 No 63 Amps DP MCBs for incoming supply Double busbar of adequate size, 12 No DP DC MCB (0-32A) including indication lamps and cables and other accessories |
| 53 | Distribution Panel (415 V, AC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43. 200 Amps Switch Fuse disconnector for incoming supply and 5 No TPN MCB's (16-125 Amps ) and 5 No DP MCBs (0-32A),Rectangular busbar suitable for 200 Amps continuous Supply including indication lamps and cables and other accessories |
| 54 | Fire Extingiusher Co₂ Type of 4.5 kg capacity for control room (with ISI mark) |
| 55 | 3 Sand Bucket Fire Extingiusher including MS stand |
| 56 | Rubber mat 1mx2m 19 mm thick |
| 57 | Led Torch |
| 58 | 33 KV Gloves |
| 59 | SURVEY,SUPPLY,TESTING AND COMMISSIONING FOR 11 kV INDOOR SWITCHGEAR OF 33/11 kV SUBSTATION at R/ Stn RAMNAGAR |
| 60 | 11 kV VCB Panel Board Set (12 kV, 1250A, 25 kA, Indoor) with O/C, E/F relays (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port SCADA Compatible etc MAKE :- Seimens, Megawin, Pascal, or Stelmec :- For 6.3 MVA Power Transformer (1+4) including Smart meters Trivector. |
| 61 | 11kV, Gapless Surge Arrestor,9 KV ,10 KA ,LA with Polymer housing, Stn. Type |
| 62 | 11 kV 3- Core XLPE 300 mm² armoured, FRLS |
| 63 | 11 kV 3- Core XLPE 240 mm² armoured, FRLS |
| 64 | 11 kV Indoor Heat Shrinkable Cable Termination Kits for 300 sqmm cable(Indoor) |
| 65 | 11 kV Indoor Heat Shrinkable Cable Termination Kits for 300 sqmm cable (outdoor ) |
| 66 | 11 kV Indoor Heat Shrinkable Cable Termination Kits for 240 sq mm Cable (indoor) |
| 67 | 11 kV Indoor Heat Shrinkable Cable Termination Kits for 240 sq mm Cable (outdoor) |
| 68 | 11 kV Isolator, double break,3-pole, 600Amp, horizental mounting Type, with Earth Switch. |
| 69 | 11kV DO set , AB Switch 3-Phase, 3-Pole, 200 Amp |
| 70 | Galvanised iron of sorts |
| 71 | 09 Mtr. Long Pole(ST-410 SP33) |
| 72 | 120 mm² PVC LT Cable 4 Core, armoured, FRLS |
| 73 | Cement bottoming 1:2:4 mix as per REC standards 0.5cum per pole |
| 74 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI strip for ST poles |
| 75 | 100 KVA , 11KV/440V Auxillary Transformer 3 phase Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2 |
| 76 | Earthing for 11KV/440V Auxillary Transformer (complete as per REC standards) |
| 77 | MCCB 200 Amp with box |
| 78 | Providing & Fixing of of BusBar System with 200 sqmm A.C.S.R.Panther Conductor,including Aluminium tension/suspension fitting suitable for Panther Conductor,T Clamps/P.G.Clamps/P.I. Clamps./C.T. Clamps/Isolator Clamps/PT Clamps etc complete job |
| 79 | Painting of ST Poles 9 Mtrs Long |
| 80 | SURVEY,SUPPLY,TESTING AND COMMISSIONING FOR 11 kV INDOOR SWITCHGEAR OF 33/11 kV SUBSTATION at R/ Stn Chak |
| 81 | 11 kV VCB Panel Board Set (12 kV, 1250A, 25 kA, Indoor) with O/C, E/F relays (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port SCADA Compatible etc MAKE :- Seimens, Megawin, Pascal, or Stelmac :- For 6.3 MVA Power Transformer (1+5) including Smart meters Trivector. |
| 82 | Supply of material to Divisional store Sub Transmission Udhampur. |
| 83 | 11kV, Gapless Surge Arrestor,9 KV ,10 KA ,LA with Polymer housing, Stn. Type. |
| 84 | 11 kV 3- Core XLPE 300 mm² armoured, FRLS |
| 85 | 11 kV 3- Core XLPE 185 mm² armoured, FRLS |
| 86 | 11 kV 3- Core XLPE 240 mm² armoured, FRLS |
| 87 | 11 kV Isolator, double break,3-pole, 600Amp, horizental mounting Type, with Earth Switch. |
| 88 | 33kv Isolator without Earthing Blade (36kv , 1250A,outdoor,3 poles, 25KA ). |
| 89 | 30 kv Lightening arrestors (30kv,10KA, Polymer, station class, ZnO)gap less for R/Stn Battal and Chowki |
| 90 | 33 kV Vacuum Circuit Breaker (36 kV, 1250A, 26.2 kA, Outdoor Type) SCADA compatible Make Megawin, BHEL,Pascal or Stelmac |
| 91 | 33 kV C&R Panel along with O/C, E/F and differential relays (IEC61850), mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port SCADA Compatible.Make Make Megawin, BHEL,ABB,Pascal or Stelmac |
| 92 | 11 KV CTs of different ratio (400/200/5/5) of make megawin/electricfield/pascal/stelmac 2 set each of make mentioned |
| 93 | Numerical Relay Earth and Over current Protection relay Make Ashida for 33KV C&R , 11 KV VCBs |
| 94 | Providing 1 No 11\\" Ipad Pro 512 GB Wifi+ Cellular M4 Chip |
| 95 | ACSR Dog conductor 100 sqmm |
| 96 | Civil /Misc Works for R/Stn Ramnagar |
| 97 | BUILDING: Repairing of Existing building by way of Plastering patches 12 -20 mm thick after scrapping and sand papering preparing the surface smooth, replacement of all doors and windows with new aluminium Doors and windows with EPDM rubber/neoprene gasket including providing and fixing hinges/pivots wit floating glass panes of thickness 8 mm thickness,pvc ceiling,all Electrical fittings(fans, LED tubelights, leds powerpoints and other fixtures) , Painting/white washing of entire control room building by way of applying white putty 1 mm thick 2 coat, sand papering preparing the surface smooth,distempering including primer and finishing with emulsion paint 2 coat (Nerolac/Asian) brand and double vitrified tiles (Kajaria/Somany/johnson) brand at (R/Stn Ramnagar) as per the directions of site engineer |
| 98 | Compound Walling of identified land by way of Mass Concrete in Foundations and 228 mm bricks of 2 metre height and plastering |
| 99 | Galvanized Chain link Fencing of 33 kV Yard of Substation by way of Mass Concrete in Foundations and chain link fencing of 6 ft height (Size 75 mm x 75 mm made of G.I.Wire 3.15 mm in diamond pattern) using Fencing posts of M.S.angle size 65x65x6mm embedded in 1:2:4 C.C. Block of Size 400 mm x 400 mm x1000m at an average spacing of 2.5 m c/c.The chain Link mesh fencing shall be secured to M.S.Angle post with flat iron strip of size 50x6 mm on both sides.There shall be a provision of 3 rows of 2 strand Barbed wire on top of fencing post. at R/Stn Ramnagar |
| 100 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required-In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.(As per direction of site incharge) |
| 101 | Dismantling and Rererection of 11 KV VCBs ,33 KV C&Rs,Battery Bank,AC/DC board,Battery charger for shifting of equipments to new control room building. |
| 102 | Painting of Gantry structure/foundation structure all MS material including chain link fancing with aluminium paint 2 coat at R/stn Ramnagar |
| 103 | Construction of R.C.C. Pillars for holding of gate including cost of material & labour.(Design of Reinforcement & sizing shall be finalised by Enginer incharge |
| 104 | RCC Cable trench (1:2:4) including excavation and disposal of un-wanted soil. for laying of 11 KV XLPE Power Cable and control cable from power transformer, VCB and other equipments to control room and for outgoing cables from control room to outgoing structures including cable duct covers (cable duct covers should be covered with Angle Frames using angle 45x45x5 mm and 8 mm Tar Steel @ 200 c/c & M-20 Concrete) |
| 105 | BUILDING: A. Control Room Building on ground floor complete with Column, beam structure and plinth protection with 1 no J.E. Room , 1 Store room, 1 Battery Room and a main hall including aluminium windows, cable ducts for power and control cable, Toilet (complete with WC, Washbasin and fittings), electric fittings (fans, LED tubelights, leds powerpoints and other fixtures of Make Havells,Anchor,RR,Philips) Painting/white washing of entire control room building by way of applying white putty 1 mm thick 2 coat, sand papering preparing the surface smooth,distempering including primer and finishing with emulsion paint 2 coat (Nerolac/Asian) brand etc. Overhead (2Nos. 1000Ltr)/undergroung water Storage tanks (14000 ltr) . 2 nos of office tables (2'6\\"x5') and 2 nos of office chairs and 4 nos of Plastic chairs , staircase . Water Supply . Septic Tank (10'x10'x8') complete with Sanitary Fittings including kota stone floor .complete in all respects |
| 106 | Providing and Fixing of CCTV cameras 6 nos with specifications IP camera 4 MP IR 30 mtr range with 8 channel NVR, POE switch , Hard Disc 4 TB, Fibre / Outdoor CAT6 whichever is required as per site conditions and LED Monitor 32 inch, Wifi /airfiber with 2 Years subscription and connection with all allied accessories like media convetrors, supporting wire, 4U Rack etc and electric connections at sites as required. |
| 107 | Repairing of shed of existing building Ramnagar , by way of replacing old damaged sheets with new GI sheets (0.63 mm thick) 180 GSM or above ,GI sheet along with hooks and screws,Flat ,Angle,Pipes etc. to be provided by the contractor including repairing of truss as per requirement of site and direction of AEE concerned. |
| 108 | Supply, Transportation, Erection of 13 Mtr Long ST Poles (ST410-SP69) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. |
| 109 | 33 kV Yard Lighting ( 4 nos of 100 Wt LEDs, 13 mtr ST poles with Ring on top) complete with earthing , cement bottoming GI brackets, control box , cable etc with centrally controlled Switch. 2 nos. for R/Stn (R/Stn Ramnagar) |
| 110 | Civil /Misc Works for R/Stn Sataney |
| 111 | Borewell with Sub mersible pump |
| 112 | RCC Cable trench (1:2:4) including excavation and disposal of un-wanted soil. for laying of 11 KV XLPE Power Cable and control cable from power transformer, VCB and other equipments to control room and for outgoing cables from control room to outgoing structures including cable duct covers (cable duct covers should be covered with Angle Frames using angle 45x45x5 mm and 8 mm Tar Steel @ 200 c/c & M-20 Concrete) Please Enable Macros to View BoQ information Compatibility Report for DhunaBOQ.xls Run on 10-07-2021 14:05 The following features in this workbook are not supported by earlier versions of Excel. These features may be lost or degraded when you save this workbook in an earlier file format. Significant loss of functionality # of occurrences This workbook contains data in cells outside of the row and column limit of the selected file format. Data beyond 256 (IV) columns by 65,536 rows will not be saved. Formula references to data in this region will return a #REF! error. 6.0 'BoQ1'!L40 'BoQ1'!F40 Any effects on this object will be removed. Any text that overflows the boundaries of this graphic will appear clipped. 3.0 'BoQ1'!A1:II42 Minor loss of fidelity Some formulas in this workbook are linked to other workbooks that are closed. When these formulas are recalculated in earlier versions of Excel without opening the linked workbooks, characters beyond the 255-character limit cannot be returned. 5Defined Names Some cells or styles in this workbook contain formatting that is not supported by the selected file format. These formats will be converted to the closest format available. 14.0 |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 12 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender