Tender For B.O.Q For Construction Of 04 Roomed Double Storied School Building At Govt. Primary School Lone Mohalla Adijen Including Toilet/ Electrification B.W.O Electric Work
Tender Value
5.03 Lakhs
Estimated cost
Bid Submission
17 Jul 2026
4 days left
EMD
10077
Bank guarantee accepted
Document Fee
300
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Shopian → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for B.O.Q For Construction Of 04 Roomed Double Storied School Building At Govt. Primary School Lone Mohalla Adijen Including Toilet/ Electrification B.W.O Electric Work
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2X 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor (Polycab Green/Havell Life guard/ Fenolex/ Salzer/RR/Apar make as desired by engineer incharge ) single core cable in surface / recessed medium class PVC conduit, including cutting the wall and making good the same in case of recessed conduit as required, with cement plaster, wall putty , paint, complete, with modular switch Antibacterial series ( Legrand /ABB / Siemens make.), modular plate,suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (incl. cost of conduit) |
| 2 | Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor (Polycab Green/Havell Life guard/ Fenolex/ Salzer/RR/Apar make as desired by engineer incharge ) single core cable in surface / recessed medium class PVC conduit,including cutting the wall and making good the same in case of recessed conduit as required, with cement plaster, wall putty , paint, complete, 2way modular switch,Antibacterial series ( Legrand /ABB / Siemens make.) modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. (incl. cost of conduit) |
| 3 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor (Polycab Green/Havell Life guard/ Fenolex/ Salzer/RR/Apar make as desired by engineer incharge ) single core cable in surface/ recessed PVC conduit,including cutting the wall and making good the same in case of recessed conduit as required, with cement plaster, wall putty , paint, complete as required. (incl. cost of conduit) |
| 4 | Wiring for light/ power plug with 2X4 sq. mm + 1X 4 sq. mm earth wire , FRLS/HFFR PVC insulated copper conductor (Polycab Green/Havell Life guard/ Fenolex/ Salzer/RR/Apar make as desired by engineer incharge )) single core cable in surface/recessed medium class PVC conduit.including cutting the wall and making good the same in case of recessed conduit as required, with cement plaster, wall putty , paint, complete (incl. cost of conduit) |
| 5 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor (Polycab Green/Havell Life guard/ Fenolex/ Salzer/RR/Apar make as desired by engineer incharge ), single core cable in surface/ recessed medium class PVC conduit as required.including cutting the wall and making good the same in case of recessed conduit as required, with cement plaster, wall putty , paint, complete (incl. cost of conduit) |
| 6 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 7 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 8 | 2 X6 sq. mm + 1 X 6 sq. mm earth wire |
| 9 | 2 X 16 sq. mm + 1 X 6 sq. mm earth wire |
| 10 | Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required |
| 11 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, Antibacterial series ( Legrand /ABB / Siemens make.)connections etc. as required. |
| 12 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,modular plate, suitable GI box , connections etc. as required. Modular Switch & Socket:- Antibacterial series ( Legrand /ABB / Siemens make.) |
| 13 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). Modular Switch & Socket:- Antibacterial series ( Legrand /ABB / Siemens make.) |
| 14 | Supplying and fixing of following sizes of medium class PVC conduit( Anchor/ Ravindra/ Eq. make)along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required, with cement plaster, wall putty , paint, complete |
| 15 | 25 mm |
| 16 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).(legrand / Schinider/ L&T ./ABB/equivalent standard make as directed by engineer incharge.) |
| 17 | 6 way (4 + 18), Double door |
| 18 | Supplying and fixing following way, horizontal type SPN, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).(legrand / Schinider/ L&T ./ABB/equivalent standard make as directed by engineer incharge.) |
| 19 | 16 way (14 +2), Double door |
| 20 | Supply installation testing and commissioning of 15 W + LED Surface/recess, Mounted light luminary fitting,square or round shape with minimum system lumen efficacy ≥ 120 lm/Watt with Pressure Die cast Aluminium Housing and Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips/ Helonix/Wipro / Regent make / sample to be approved before installation.. |
| 21 | S/F testing and comm. Of surface mounted LED Batten 20 watt-22 watt +- 1watt commercial series (cool/warm) 4 ft. with minimum system lumen efficacy of ≥ 120 lm/Watt with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. Philips/ Helonix /Wipro make. sample to be approved before installation. |
| 22 | S/F testing and comm. Of MCB's 10 kA of the below mentioned capacities in sub main controls legrand C curve/ Schinider Acti 9/ L&T ./ABB make as directed by engineer incharge. |
| 23 | a) 6-32 Amp SP MCB |
| 24 | b) 40-63amp DP MCB |
| 25 | Supply installation testing and comm. Of 200-250mm sweep exhaust fan Shutter type of havell /Bajaj/Crompton make as directed by engineer incharge, including making of space in wall/ window as per site requirement and necessary connections. |
| 26 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, ceiling fan with 3 No. Aluminium blades, 30 cm long down rod, 2nos. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, and including iron hook complete . USHA /Havells /Crompton/orient make as directed by engineer incharge. |
| 27 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.Antibacterial series ( Legrand /ABB / Siemens make.) |
| 28 | Supply fixing testing and comm. Of backlite holder /batten holder/angle holder/ceiling rose SSK/Anchor make incl. PVC Block. |
| 29 | Providing of Chemical earthing as per IS standards by way of digging 10' deep pit then embedding 3 meter G.I Earthing electrode , 80mm dia. connecting the plate with main control board by 10 SWG copper wire with 1/2\\" dia. Full thread brass nut and bolt and washers. Refilling of pit with chemical compound. |
| 30 | Supply, laying ( partly underground/partly overhead) , testing and commissioning of PVC alluminium un-armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminium lugs of required size. |
| 31 | d)25 sq.mm 2 core ( un-armoured) |
| 32 | Design, Fabrication, Supplying, Installation, Testing and Commissioning of following panel, duly manufactured from CPRI approved manufacturer, made out of 2mm thick M.S. sheet steel , floor/wall mounted, vermin and dust proof, indoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of following switch gears, , Aluminium Bus Bar of various ratings after taking Derating factor into account, and other allied accessories etc. as required.( As per approved design,size may vary as per site requirement) |
| 33 | Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required. |
| 34 | Normal INCOMING: |
| 35 | Adj. TMR Based MCCB 125 Amps DP Icu=Ics=100% Breaking Capacity 36 KA with Extendable ROH Legrand/ Shinider/Semiens/ABB make. |
| 36 | b) 2 strip Aluminium Bus Bar of 200 Amp. |
| 37 | c)Digital meters and phase indicators -1 set. |
| 38 | OUTGOING: |
| 39 | c) 40-63amp DP MCB c curve 10 K Legrand/ Shinider acti-9/ABB make, sample to be approved before installation.. |
| 40 | c) space for 6 way MCB's Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 02, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysJul 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender