BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.50 mtr depth for foundation etc or for shafts, wells, cesspits, main holes, pier holes etc complete in soft/loose soil complete all as specified and directed. |
| 2 | Returning, filling including spreading, levelling, watering and well ramming in layers n.exc. 25 cm thick in soft/loose soil complete all as specified and directed. |
| 3 | Removing excavated materials not exc 50 mtr and deposited where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and as directed. |
| 4 | M&L construction of brick masonry valve pit / chamber of size 600mm x 600mm x 600mm (internal dimensions of chamber) using 50% new bricks built in one brick thick wall in cement mortar 1:4) including top of MS cover with MS sheet cover 3mm thick including frame of angle iron 40 x 40 x 6mm with locking arrangement, lifting handle and 02 Nos 100mm size MS butt hinges including painting two coats of black synthetic enamel paint over a coat of red oxide primer, 15mm thick plastering in cement mortar (1:4) (internally on all brick wall and external upto 15cm below ground level) and necessary excavation and earth work in any type of soil, returning, filling in, disposal of surplus spoil to a distance not exceeding 50 mtr, 15 cm thick PCC (1:4:8) type D-2 in foundation projected by 15cm all round from the outer face of brick wall, PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) 40mm thick in coping including dismantling of old unserviceable valve pit chambe complete all as specified and directed. |
| 5 | Rectification of leakage / blockage / any defects noticed in CI / DI / GI / PPR / uPVC pipe of dia 15mm, 20mm, 25mm, 40mm, 50mm, 65mm including detecting and locating leakage/blockage by replacing pipe upto required length as directed including excavation of earthwork in all kinds of soil for exposing leak portion of the pipe only including road/concrete cutting, removing and stacking the damaged portion from the existing line without causing any damages to the remaining portion and specials and covering and replacing with pipes of suitable size and jointing by supplying threaded PPR coupler and PPR union of dia upto 63mm including threading, alignment, laying and jointing to make the water tight joint, Cont/- |
| 6 | Cont/-testing the line to the required pressure upto service tank located at Md/OTM Accn refilling the trenches in layers not exceeding 15cm depth including consolidating each layers by ramming , watering, removing the surplus soil from the working site without causing any damages to any other utility services including hiring charges for conveyance of tools, plant, pump and any materials required at site, bailing out of water, bamboo ladder in case of multi-story building, lighting arrangement in night hours, ribbon fencing, caution boards traffic diversion complete all as spcified and directed.Cont/- |
| 7 | Cont/-Note:(i) Pipe length of PPR/UPC any size required for rectification of any defects will be measured and paid seperately under repective items.(ii) PCC work required at site to make good the broken damaged hard standing surface will be measured and paid seperately under repective items.(iii) PPR/UPVC fittings of dia 20mm and above required at site for rectification of any defects in PPR/UPVC pipe will be measured and paid seperately under repective items.(iv) Excavation & earth work required for detection of blockage except leakage willl be measured and paid seperately under repective items.Cont/- |
| 8 | Cont/-(vi) Contractor shall deploye at least 4 plumber (skilled tradesman) to attend daily complaints for rectification. Workmans shall report compaint cell of AGE E/M (Water Supply) daily at 8.30 AM to collect complaint and complete the complaint/rectification work by 5.30 PM. A penalty of Rs. 800/- per day- per complaint for not attending (absentee) shall be imposed and same shall be deducted / recovered from contractors dues/RARs.(vii) No extra payment of attendng complaints shall be admissibe to contractor. The rates quoted by the contractor are deemed to be included all above provisions. |
| 9 | Taking up or down steel water tubing and connection from any position complete as directed of the following sizes:- |
| 10 | 15mm dia bore |
| 11 | 20mm dia bore |
| 12 | 25mm dia bore |
| 13 | 40mm dia bore |
| 14 | 50mm dia bore |
| 15 | Taking up or down PPR pipe and connection from any position complete as directed of the following sizes:- |
| 16 | 20mm dia bore |
| 17 | 25mm dia bore |
| 18 | 32mm dia bore |
| 19 | 50mm dia bore |
| 20 | 63mm dia bore |
| 21 | Taking up or down PVC water tubing of 20mm bore and connection from any position complete as specified and directed. |
| 22 | Supply, laying, Jointing & Testing 3-layer PP-R (polypropylene random copolymer) concealed pipes SDR 7.4 (PN-16) UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings as socket, elbow, reducer, end cap, male & female threaded elbow, male & female threaded socket, Tee fixed complete to walls, ceilings, floor or in trenches etc. complete all as specified and directed of the following sizes:- |
| 23 | 20mm dia bore |
| 24 | 25mm dia bore |
| 25 | 32mm dia bore |
| 26 | Supply, laying, Jointing & Testing 3-layer PP-R (polypropylene random copolymer) concealed pipes SDR 7.4 (PN-16) UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings as socket, elbow, reducer, end cap, male & female threaded elbow, male & female threaded socket, Tee, wall clamp & other accessories laid in trenches etc complete all as specified and directed of the following sizes:- |
| 27 | 50mm dia bore |
| 28 | 63mm dia bore |
| 29 | M&L for in replacement flat iron clamp made up of 32mmx5mm width flat iron MS sheet in two half including one half having a hole and welded one GI socket of 20mm dia on top of hole suitable for following size of pipe including nuts and bolts rubber packing complete all as specified and directed: |
| 30 | 80mm dia bore |
| 31 | 100mm dia bore |
| 32 | 150mm dia bore |
| 33 | S&F in repair 20mm dia PTMT ball valve high Pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (min wt 142 gms) complete all as specified and directed. |
| 34 | S&F PP-R Ball valves (brass insert) 20mm as per requirement of the site complete including taking down old gate valve all as specified and directed. |
| 35 | S&F PP-R Ball valves (brass insert) 25mm as per requirement of the site complete including taking down old gate valve all as specified and directed. |
| 36 | S&F PP-R Ball valves (brass insert) 32mm as per requirement of the site complete including taking down old gate valve all as specified and directed. |
| 37 | S&F PP-R Ball valves (brass insert) 50mm as per requirement of the site complete including taking down old gate valve all as specified and directed. |
| 38 | S&F PP-R Ball valves (brass insert) 63mm as per requirement of the site complete including taking down old gate valve all as specified and directed. |
| 39 | M&L for cutting of road/hard standing surface for laying/removing of pipe lines suitable upto 50mm dia upto 1.0 mtr depth of hardstanding / roads bottom layer including making good in original shape by providing proper size stone boulder as in sub base and 100 mm thick PCC (1:4:8) type D-2 after laying/removing of same complete all as specified & directed. |
| 40 | Supplying and laying in replacememt of Unplasticiscd PVC pipes of 63 mm outer dia with all fittings of pressure rating 10 kgf/cm2 laid in trenches complete all as specified and directed. |
| 41 | Supplying and laying in replacememt of Unplasticiscd PVC pipes of 75 mm outer dia with all fittings of pressure rating 10 kgf/cm2 laid in trenches complete all as specified and directed. |
| 42 | Supplying and laying in replacememt of Unplasticiscd PVC pipes of 90 mm outer dia with all fittings of pressure rating 10 kgf/cm2 laid in trenches complete all as specified and directed. |
| 43 | S&F in replacement of control valve of size 63 mm made up of rigid PVC fixed with teflon seal complete all as specified & directed. Make : Supreme/Prince/Jain Irrigation |
| 44 | S&F in replacement of control valve of size 75 mm made up of rigid PVC fixed with teflon seal complete all as specified & directed.Make : Supreme/Prince/Jain Irrigation |
| 45 | S&F in replacement of control valve of size 90 mm made up of rigid PVC fixed with teflon seal complete all as specified & directed.Make : Supreme/Prince/Jain Irrigation Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 3 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender