Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #56266584

Tender For Repair / Replacement And Maintenance Of Ht Network, Ht Ug Cable, Vcbs, Rmu, Transformer, Gods And Allied Misc Work At Mil Stn Dhrangadhra.

Issued by Statutory Bodies & Commissions/Committees · Gandhinagar, Gujarat
Tender Value
Ref. Documents
Estimated cost
Bid Submission
22 Jul 2026
0 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gandhinagar → Gujarat
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair / Replacement And Maintenance Of Ht Network, Ht Ug Cable, Vcbs, Rmu, Transformer, Gods And Allied Misc Work At Mil Stn Dhrangadhra.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 11-Jul-2026 Financial Corrigendum Financial Bid 22-Jul-2026

BOQ

Name of Work:- REPAIR / REPLACEMENT AND MAINTENANCE OF HT NETWORK, HT UG CABLE, VCBS, RMU, TRANSFORMER, GODS AND ALLIED MISC WORK AT MIL STN DHRANGADHRA.
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CWE (A) AHMEDABAD NAME OF WORK: REPAIR / REPLACEMENT AND MAINTENANCE OF HT NETWORK, HT UG CABLE, VCBS, RMU, TRANSFORMER, GODS AND ALLIED MISC WORK AT MIL STN DHRANGADHRA. Contract No: CWE (A)/GNR/ OF 2026-2027 SERIAL PAGE NO Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # SL NO ITEM DESCRIPTION Item Code / Make QTY UNITS Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
2Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for foundation of pole,laying of cables etc in Hard and dense soil and getting out.
3Returning filling in including spreading, leveling, watering and well ramming in layer not exc 25 cm.
4Removing excavated material not exc 50 mtr and depositing where directed at a level not exc. 1.5 m above the starting point.
5Material and labour for providing dry river sand as in sand cushioning to UG cable including punning gently all as directed. Note : Depth after punning shall be measured and paid.
6Material and labour for plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundtion of PCC poles/struts all as specified and directed.
7Material and labour for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for padestal/coping around poles, including necessary form work, finishing even and smooth without using extra cement, all as specified and directed.
8laying only un-reinforced precast concrete cable cover, class EHV,complete all as specified and directed.
9Supplying and laying precast concrete cable cover, class EHV, type 1 with peak, size 450mm x 230mm x 50mm complete all as specified and directed.
10Supply , Laying , jointing in repairs of HT 11KV Earthed XLPE insulated PVC sheathed armoured heavy duty electric cables with aluminium conductor for working voltage upto and including 11000 volts of cross sectional area 185 Sqmm 3 core all as specified and directed. make:- Havells, gloster,polycab
11Supply , Laying , jointing in repairs of HT 11KV Earthed XLPE insulated PVC sheathed armoured heavy duty electric cables with aluminium conductor for working voltage upto and including 11000 vlots of cross sectional area 150 Sqmm 3 core all as specified and directed. make:- Havells, gloster,polycab
12Supply , Laying , jointing in repairs of HT 11KV Earthed XLPE insulated PVC sheathed armoured heavy duty electric cables with aluminium conductor for working voltage upto and including 11000 vlots of cross sectional area 120 Sqmm 3 core all as specified and directed. make:- Havells, gloster,polycab
13Supply , Laying , jointing in repairs of HT 11KV Earthed XLPE insulated PVC sheathed armoured heavy duty electric cables with aluminium conductor for working voltage upto and including 11000 vlots of cross sectional area 95 Sqmm 3 core all as specified and directed. make:- Havells, gloster,polycab
14Material and labour in repairs Cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm to 120 sqmm Make M-SEAL, DENSONS,BIRLA-3M
15Material and labour in repairs Cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm Make M-SEAL, DENSONS,BIRLA-3M
16Material and labour in repairs Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing materialand accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm Make Raychems, DENSONS,CCI
17Material and labour in repairs Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing materialand accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm Make Raychems, DENSONS,CCI
18Material and labour in repairs Cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm Make Raychems, DENSONS,CCI
19Material and labour in repairs Cable jointing kit for 11 KV (Earthed) gradecable for straight through cold shrink type joint complete with jointing material andaccessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm 185 sqmm. Make Raychems, DENSONS,CCI
20Material and labour in repairs for Cross arms, bracings, supports, clamps,sheet and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including taling down old and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.make as per SI
21Taking out the existing XLPE, 11000 volts grade, HT UG electric cable of size 95 sqmm x 3 core with glands complete from the trenches/fixed on wall (or) passing through pipes/in floor as specified and directed by the Engr-in- charge Note:- Excavation and Earth work shall be measured and paid separately under appropriate items all as per existing make
22all as per item no 20 but 120 sqmm x 3 core
23all as per item no 20 but 150 sqmm x 3 core
24all as per item no 20 but 185 sqmm x 3 core
25Re-Laying only in trenches/fixed on wall (or) passing through pipes/in floors, connecting up testing and commissioning of Serviceable XLPE , 11000 volts grade, HT UG electric cable of size 95 Sqmm x 3 core cable
26all as per item no 24 but 120 sqmm x 3core
27all as per item no 24 but 150 sqmm x 3core
28all as per item no 24 but 185 sqmm x 3core
29Supply and fix, in repair, GI pipe 80mm bore, light grade, laid below road / fixed along the poles / walls with necessary clamping, etc including taking down old complete all as per specified and directed. Make jindal,prakesh,tata steel
30Supply and fix, in repair, GI pipe 100mm bore, light grade, laid below road / fixed along the poles / walls with necessary clamping, etc including taking down old complete all as per specified and directed. Make jindal,prakesh,tata steel
31Material and labour for preparation of old painted (outer exposed surface) of electric steel tubler poles over all diminsion 8.5/9.0 meters long, painting starts above ground level including MS channel / angle iron with bolts, nuts of four pole stracture and applying one coat of aluminium paint including writing pole No with black colur of existing size letters all as specified and as directed.
32Material and labour for preparation of old painted (outer exposed surface) of electric steel tubler poles over all diminsion 8.5/9.0 meters long, painting starts above ground level including MS channel / angle iron with bolts, nuts of two pole stracture and applying one coat of aluminium paint including writing pole No with black colur of existing size letters all as specified and as directed.
33Supply & fixing air break switch (GOD) 11KV triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps and incl taking down the old items.
34Horizontal Boring by Passing GI Protection Pipe up to 150 mm Bore (dia), under Road /Foot Path, not exc. 10.00 METRE in a Single Length, complete all as specified and as directed.
35Material and labour for fault finding of HT,11KV cable by using cable fault dectector machine and other necessary T&P, finding out the spot of cable fault and marking on ground complete for any size and length of cable all as specified and directed. (Note : Fault dectector and other necessary T&P shall be arranged by the contractor without pay any extra cost by the Dept.)
36Material and labour in repairs for Danger notice plate of 1.6mm thickmild steel sheet, vitreous enamelledwhite, with letters, figures andconventional skull and bones insignal red colour and fixed withM.S. clamps, bolts and nuts ofapproved size, for HT, 25X20cmsize including taking down old one
37Supply and fix in repairs continuity conductor or main earthing strip lead fixed to wall buried inground or drawn in conduit/pipe or fixed to poles for loop earthing etc. asrequired 32x6mm galvanised iron including taking down old one
38Supply and erecting in repairs of CI Cable path indicators made out of MS sheet duly marked with HT cable 11000 volts and with MS angle embeded in PCC 1:4:8 with 60 cm below ground level and 30cm above ground with sheet painted by \\" silver colour” complete all as specified and directed by Engr-in-charge.including taking downold one
39Supplying and laying In repairs synthetic Rubber insulated mats 25 mm thick for voltage 11 kv for electrical purposeas per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m
40Opening Top Lid Cover of Transformer 100KVA to 200KVA, 11000/433V outdoor type, disconnecting all Internal Connections of HT/LT Side for Cleaning of Core and Winding by means of Washing by Hosing Down with Clean Dry Oil to removed Dust/Sludge on Core and Coil, Cleaning of Oil Tank to removed Sludge deposited, Replacement of Rusted Gasket Set, Burnt Spindle, Broken/ Unserviceable HV/LV Ceramic Bushing, Broken Arc Horn, Surge Arrestor, Replacement of Silica Gel, etc. complete all as specified and as directed. (a) Cost of Transformer Oil for Cleaning by Hosing down shall deem to be included in the QUOTED UNIT RATE. (b) Gasket Set, HT/LT Side Ceramic Bushing, Spindle for HT/LT Side and Are Horn Surge Arrester etc. for Replacement shall deem to be including in the quoted rate.
41Dehydration/Filtration of Transformer Oil by means of Centrifugal Filtration Plant to achieve the specified Di-electric Strength not less then 40 KV at 2.5mm Gap in Existing Position of Transformer of any Capacity and Transformer Oil for Topping Up at various Transformer location complete all as specified and as directed.NOTE : Transformer Oil to be used for TOP UP shall be Measured and Paid for separately.
42Supply & Topup of New Transformer Oil, conforming to IS:335-1983 to achieve a Di-electric Strength not less then 40 KV with Oil Testing Kit 4.0mm thick to Top Up of the Transformer complete all as specified and as directed.
43Supply & fix in repairs/ replacement of Breather Assembly filled with Silica Gel same as existing size and weight approved and suitable for Transformer up to 200 KVA complete all as specified and as directed
44Supply and fixing in repairs/ replacement of silica gel after replacing old u/s one. all as specified and as directed
45Supply and fixed in repairs/ replacement of Brass Spindle for Terminal on HT Side Threaded complete with Nut, Washers, etc. same as existing size and suitable for Transformer 63KVA TO 200KVA 11000/433V, after replacing old u/s one.complete all as specified and as directed.
46Supply and fixed in repairs/ replacement of Brass Spindlein repairs Terminal on LT Side Threaded complete with Nut, Washers, etc. same as existing size suitable for Transformer 63KVA TO 200KVA 11000/433,after replacing old u/s one. complete all as specified and as directed.
47Supply and fixed in repairs/ replacement of Ceramic Bushing and Gasket on LT Side of Transformer same as existing size 63KVA TO 200KVA 11000/433 after replacing old u/s one.complete all as specified and as directed.
48Supply and fixed in repairs/ replacement of Ceramic Bushing and Gasket on HT Side of Transformer 63KVA TO 200KVA 11000/433 after replacing old u/s one.complete all as specified and as directed.
49Supply and fix in repairs/ replacement of Gasket (Cock Sheet) 6.0mm thick with Conical Rubber Bush Complete as approved and suitable for Transformer 63KVA TO 200KVA 11000/433 including Taking down/ out unserviceable Gasket, complete all as specified and as directed.
50Material and labour, in repairs, earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6 mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth strip of 32x6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SSR Part I connected to earth test point using as earth lead all as specified and testing on completion including provision of earth lead protected by 40 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work in any type of soil, PCC pit with RCC cover, char coal, salt, funnel etc complete. Note : Rate quoted by tenderers shall be deemed to include for following provisions;-[i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 M.[ii]. PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles.[iii]. Main earthing lead from earth electrode to test point upto 7.5 mtr.[iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs, charcoal & salt as reqd.[v]. GI protection pipe of size 40 mm bore light grade 7.5m.
51Material and labour for opening HT, 11KV,400Amp, VCB front and back side complete after taking shutdown HT breaker ,Timing test ,CRM test,insulation resistance test,relay test by secondary injection,check motor charge mechanism,potential transformer resistance measurment,checking control power cable connection , cleaning the dusting inside & out side of VCB greasing oiling the mechanical parts and relay setting of VCB and Complete servicing and testing Over load relay, digital voltmeter, digital ammeter, indication lamp and all the protective equipment inside the VCB to be serviced and working properly with necessary replacement of defective equipments complete all as specified and directed by Engr-in-Charge NOTE : replacement of the following item of (a) to (k) shall be Measured and Paid for separately
52(a) Replacement of indicating lamps all as existing make and size
53(b) Replacement of internal wiring for indicating lamps
54(c) Replacement of wiring for tripping coil (No volt coil), tripping switch set
55(d) Replacement of No Volt coil of suitable capacity
56(e) Replacement of power pack dual input/110 volt DC as per existing size and make
57(f) Replacement of systhetic rubber boot
58(g) Replacement of calix spring charge input handle
59(h) Replacement of CGI-14 C Relay OR 14N
60(I) Replacement of rack in rack out gear
61(j) Replacement of 11 KV PT FUSES
62(k) Replacement of spring charging motor
63Material and labour for opening off HT RMU compact outdoor type which consists of, cleaning the dusting inside & out side , and decarbonising the contact and applying greasing/ oiling for the mechanical parts and including the replacement of the defective items as following :-(a) Replacement of indicating lamps -03Nos(b) Replacement of internal wiring for indicating lamps-03 nos(c) Replacement of wiring for tripping coil (No volt coil) , tripping switch set(d) Replacement of No Volt coil of suitable capacity-01 no(e) Complete servicing and testing of RMU,check control cable connection,check power cable connection, checking gas pressure in RMU, checking Earth fault relay, Over load relay, digital voltmeter, digital ammeter, indication lamp, over load triping setting and all the protective equipment inside the RMU to be serviced and working properly with necessary replacement of defective equipments complete all as specified and directed by Engr-in-Charge.(f) Cleaning systhetic rubber boot if damaged change the boot.
64Material and labour for Dismantling/ taking out incoming & outgoing HT 11KV cable from RMU 11KV 630A and taking out RMU from the plateform/foundation with the help of chain pulley and hydra arrengement and taking out to the work shop/factory to refilling SF6 Gas and repairs/replacement of falted item for smooth functioning of RMU and control system and the same to be refixing on the plateforme /foundationafter repairs/replacement of SF6 Gas and connecting item and refixing including labour and transportation charges complete all as specified and directed by Engr-in- Charge Note:-1. Bas barpanel shall be fixed in lieu of UNSV RMU the HT Bus bar panel to be measured and paid seperataly under this schedule .2. transpotation charges shall deem to be included in the QUOTED UNIT RATE
65Supply and fix in repairs/ replacement of Lightning Arresters Non-Linear Type, complete with all Fittings including GI wire 6mm dia with pvc pipe upto earth test point ,nut bolts and Transmission Class, Discharge Capacity 65Kilo Amp suitable for 11000 Volt, complete all as specified and as directed.
66Supply and spread 40mm to 80 mm graded stone aggreate under the sub station installation area all as specified and directed by the Engineer in Charge
67Material and labour for Dismantling/ taking out incoming & outgoing HT 11KV cable from RMU 11KV 630A and taking out RMU from the plateform/foundation with the help of chain pulley and hydra arrengement and taking out to the work shop/factory to repairs/replacement of RMU machanical lever change with connecting rod and U type bush with connecting assembly item for smooth functioning of RMU and control system and the same to be refixing on the plateforme /foundation after repairs/replacement of mechanical link and connecting item and refixing including labour and transportation charges complete all as specified and directed by Engr-in- Charge Note:-. transpotation charges shall deem to be included in the QUOTED UNIT RATE
68Material and labour for cleaning of MES electric supply installations/campus inside Transformer chain linking fencing and from outer area of chain link fenicing i.e distance from fencing of 2 Mtrs by surface dressing or trimming of natural ground to remove small unequalities not exc 15 cm deep (including removing vegetation/ shrubs/brush wood/under growth) and carrying away the rubbish to a distance of not exc 50 mtr away complete all as specified and directed for the MRS and various transformer area. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56266584
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 22-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Replacement And Maintenance Of Ht Network, Ht Ug Cable, Vcbs, Rmu, Transformer, Gods And Allied Misc Work At Mil Stn Dhrangadhra.
Basic Detail
Tender No 87537/E8
Bidding Type Tender
Location
City Gandhinagar
State Gujarat
Key Dates
Publish Date 11 Jul 2026
Submission Date 22 Jul 2026
Open Date 01 Jan 0001
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 70000
Exemption Available
Document List
4209cb48-48d3-4b95-a667-a9dd4505341b.html
BOQ_868901.xls
TENDER.pdf
Tendernotice_1 (1).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 22, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed

Tender Documents

Download All (ZIP) ↓
html

4209cb48-48d3-4b95-a667-a9dd4505341b.html

xls

BOQ_868901.xls

pdf

TENDER.pdf

pdf

Tendernotice_1 (1).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders