Tender For Miscellaneous Electrical And Air Conditioning Related Works In And Around Nrep
Tender Overview
Project Description
Tender for Miscellaneous Electrical And Air Conditioning Related Works In And Around Nrep
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 16-Jul-2026 | Corrigendum 1- Amendment, Date extension, Reply to queries | Date | 23-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supply of 2.0TR Tower AC: Supply of 2.0TR Tower AC in complete including indoor and outdoor unit. Technical specifcations : Cooling Capacity-2.0TR, Star Rating- 1 (min), Rated Cooling Capacity-6150 (min), 230V, 50hz, 1-phase, Noise Level (indoor) -≤43, Compressor Type-Rotary, Refrigerant Gas-R32, Indoor Coil- Hydrophilic Fin and Tube (inner grooved copper tube), Outdoor Coil-Fin and Tube (inner grooved copper tube). Make-Voltas (4503505W- FAC 241 CZMM) or equivalent and as per direction of E-i-C |
| 2 | Supply of 3.0TR Tower AC: Supply of 3.0TR Tower AC in complete including indoor and outdoor unit. Technical specifcations : Cooling Capacity-3.0TR, Star Rating- 1 (min), Rated Cooling Capacity-10510 (min), 415V, 50hz, 3-phase, Noise Level (indoor) -≤55, Compressor Type-Twin Rotary, Refrigerant Gas-R32, Indoor Coil- Hydrophilic Fin and Tube (inner grooved copper tube), Outdoor Coil-Fin and Tube (inner grooved copper tube). Make-Voltas (4502882W1-FAC 361 CZMM) or equivalent and as per direction of E-i-C |
| 3 | Supply of 1.5 TR Split AC: Supply 1.5 T split AC. Detailed technical specification are as follows for split AC:1. Technology of AC : Inverter AC (Variable Speed)2. Refrigerant Type :R323. Refrigerant Global warming potential (GWP) :675 (For R32)4. Refrigerant Ozone Depletion Potential is Zero :Yes5. Heating :Cool Only6. Coil Material (Evaporator) :Copper7. Coil Material (Condenser) :Copper9. With 7 stage air treatment and nano tech. coating for evaporating tube.8. Compressor Warranty ( A ) :5.09. BEE Star Rating (Central Ministries:: Departments while procuring shall ensure thatthe items carry 5 star (under normal conditions where annual usages is expected tobe more than 1000 hrs),3 Star(where usage is Limited)or higher Star Rating of BEE):510. Nominal cooling capacity(Ton) (1 ton = 3000 kcal::Hr) (+::-10%) :1.5 Ton11. Conformity to Indian Standard: As per IS 1391(latest) Part 2 for Room Air Conditioners.12. Availability of BIS Certification : Yes13. Green Room Air Conditioner Compliant: Yes14. Company Certification : ISO 1400115. Technical Parameters16. Technology of AC: Inverter AC(Variable Speed)17. Nominal cooling capacity(Ton) (1 ton = 3000 kcal/hr) (+/-10%): 1.5 Ton18. Energy Performance Threshold (ISEER)(Wh/Wh) (for Greenroom AC): >/= ISEER 5.419. Refrigerant Type : R3220. Coil Material (Evaporator) : Copper21. Coil Material (Condenser) : Copper22. Input Power Supply : 230V ac, 50Hz23. Connecting pipe length (meter): 3 metre24. Material of Air Filter : Synthetic fibre25. Reusable Air filter: Yes26. Noise level: As per latest IS 139127. Environmental Friendly Paint: Yes28. AC Modes: Turbo Mode, Dehumidification mode, Power Saving Mode, Auto CleanMode, Self Diagnosis Mode, Quiet Mode, Dry Mode, Eco saving, Anti Mildew29. Remote Control Features*: Timer, Child Lock, Night Glow Buttons30. Mandatory Marking: Manufacturers name, model, size, type, name and quantityofrefrigerant, rated voltage, phase, rated frequency, nominal cooling capacity, powerconsumption at rated conditions, nominal current at rated conditions.31. Accessories inclusive in the scope of supply: Installation kit, 2 nos of remotecell,manual and remote.32. Warranty/Services :AC machine warranty: 1 YearCompressor warranty: 5 years\\" |
| 4 | Supply of 50 X 6 MM Hot Dip Galvanised GI Flat. The contractor shall supply the required materials to complete the earthing installation, the materials for welding of earthing conductor joints, GI clamps, GI fastners( minimum 4 nos), Lugs at earth plate & at equipment end (minimum 6) wherever required, supply of bitumin paint & hessian tape for underground joints & cold zinc spray for above ground joints. |
| 5 | Supply of 25 X 6 MM GI Flat: SUPPLY OF 25 X 6 MM Hot Dip Galvanised GI Flat. The contractor shall supply the required materials to complete the earthing installation, the materials for welding of earthing conductor joints, GI clamps, GI fastners( minimum 4 nos), Lugs at earth plate & at equipment end (minimum 6) wherever required, supply of bitumin paint & hessian tape for underground joints & cold zinc spray for above ground joints. |
| 6 | Supply of 16 mm Dia Hot Dip Galvanised GI Wire Rope |
| 7 | Supply of 150(W) X 100(H) mm Straight Run Cable Ladder Type GI Cable Tray Straight Element.600mm width,(100mm side rail, 3 meter long) 3 mm thick, spacing of rungs at 250 mm, Galvanised Steel & ladder type trays, complete with necessary coupler plates, accessories & hardwares (All hardware such as bolts, nuts, screws, washers will be stainless steel of SS-304 grade). |
| 8 | Supply of DC cable gland 4C x 25 sqmm: Supply of Double compression Nickel plated brass cable gland suitable for outdoor, with soft sealing nylon washer, locknut, shrouded & earth tag, Weather proof, IP65, for Aluminium / Copper Armoured cable for following size and asper directions of Engineer-in-Charge.1.1 KV, 4C x 25 Sqmm, CU, XLPE, Armoured |
| 9 | Supply of DC cable gland 4C x 95 sqmm: Double compression Nickel plated brass cable gland suitable for outdoor, with soft sealing nylon washer, locknut, shrouded & earth tag, Weather proof, IP65, for Aluminium / Copper Armoured cable for following size and as per directions of Engineer-in-Charge.1.1 KV, 4C x 95 Sqmm, CU, XLPE, Armoured |
| 10 | Supply of PVC Enclosure / BoardSize:12\\"x10\\"x2\\"Made of PVC materialMake:Presto Plast / Presto Teak / Richa. |
| 11 | Supply of SwitchRating: 6A , 1-WayVoltage range: 240V ACType : Ivory colour Piano typeMake :Anchor(part no1014 )or equivalent of other |
| 12 | Supply of SwitchRating: 16A , 1-WayVoltage range: 240V ACType : Ivory colour Piano typeMake :Anchor(part no10106 )or equivalent of otherConforming to ISI :3855 |
| 13 | Supply of SocketRating: 6/16A , 6 PinVoltage range: 240V ACType : Ivory colour ( 16A & 6A Universal) typeMake :Anchor ( Part no.10140 )or equivalentConforming to ISI :1293 |
| 14 | Supply of 3-pin TopRating: 6AVoltage range: 240V ACIvory colourConforming to IS:6538.Make: Anchor(Anchor part No.3097) or equivalent |
| 15 | Supply of 3-pin TopRating: 16AVoltage range: 240V ACIvory colourConforming to IS:6538.Make: Anchor (Anchor part No.3122) or equivalent |
| 16 | Supply of Flexible Copper Cable; 3Cx2.5sqmm; 1100V grade; PVC insulated;PVC Sheathed;multistranded; unarmoured; conforming to IS:694; |
| 17 | Supply of GI pipes,class B/sleeves 100 NB and as per direction of E-i-C. |
| 18 | Supply of 6 Ft. Aluminium Folding Platform Ladder.# Aluminium Self Supporting Folding Platform Ladder# Construction : Manufactured from High Tensile Aluminum Alloys.# Size of Aluminum ‘C’ Sections: 66mm x 33mm x 3.18 mm(Deviation is accetable only after review)# Rungs: 1\\" dia. non-slip corrugated rung pipe at 12\\" CTC(Deviation is accetable only after review)# Platform size: 16\\" length x 8\\" width or equivalent(Deviation is accetable only after review)# Ladder Footings: Solid rubber shoe to avoid surface scratching.# Other features: Should Light in Weight, Fire Proof & Dust Proof# Height : 6 feet.# Load bearing capcity 150Kg (Min)# Conforms to latest IS 733 and IS 1285 |
| 19 | Supply of 10 Ft. Aluminium Folding Platform Ladder.# Aluminium Self Supporting Folding Platform Ladder# Construction : Manufactured from High Tensile Aluminum Alloys.# Size of Aluminum ‘C’ Sections: 66 mm x 33 mm x 3.18 mm(Deviation is accetable only after review)# Rungs: 1\\" dia. non-Slip corrugated rung pipe at 12\\" CTC# Platform size: 16\\" length x 8\\" width.(Deviation is accetable only after review)# Ladder Footings: Solid rubber shoe to avoid surface scratching.# Other features: Should Light in Weight, Fire Proof & Dust Proof# Height : 10 feet.# Minimum load bearing capacity : approx 150Kgs# Conforms to latest IS 733 and IS 1285 |
| 20 | Supply of Al ring type lug of size 25 sqmm of make dowells or equivalent as perdirection of EIC |
| 21 | Supply of Al ring type lug of size 95 sqmm of make dowells or equivalent as perdirection of EIC |
| 22 | Supply of Al ring type lug of size 300 sqmm of make dowells or equivalent as per direction of EIC |
| 23 | Supply and laying of 1000 mm wide safety synthetic insulating mat (pastable type)complying to IS-15652 latest edition, of following grades required for maintenance of electrical equipment in substation, including cutting to required shape in runninglength, including all labour and materials, as per applicable Indian or Internationalstandards and CEA Guidelines.Rubber Mat 33 kV |
| 24 | Supply of high voltage insulation tape: Supply of Self fusing Insulation tape having corona & ozone resistance UV resistance, moisture proof, chemical and corrosionresistance for outdoor & underground application.Can be used for voltage 600V-33KV.Recommended make:Stanvac/ Permacel or equivalent and as per direction of E-i-C. |
| 25 | Supply of Silica Gel: Supply of Self indicating Blue silica gel Mesh size:3-4(6-8 mm) . When free frommoisture the crystals of silica gel to be blue and when take upmoisture it should turn pink and need replacement or regeneration. |
| 26 | S & I of Outdoor Stand: Supply and Installation of metal stand for outdoor AC unit with all accessories required for installation and as directed by EIC |
| 27 | S & I of drain pipe: Supply and installation of drain pipe from Indoor AC unit. |
| 28 | S & I of Copper pipe: Supply and Installation of copper pipe pair between AC IDU & ODU with nitrile rubber. As required as per site condition and as directed by EIC |
| 29 | Installation, testing and commissioning of AC including split type, tower type, etc. and as per direction of E-i-C. |
| 30 | Dismantling of existing AC system (split/Tower/Cassette AC) in complete (including indoor & outdoor unit) and as per direction of E-i-C. |
| 31 | Shifting/relocation of existing AC system (split/Tower/Cassette AC) in complete (including indoor & outdoor unit) and as per direction of E-i-C. |
| 32 | S&I of 32A TP RCCB along with RCCB enclosure |
| 33 | Supply and install of Earth electrode: Earth Electrode shall be supplied and installed as per the below mentioned standards including preparation of concrete chamber as inspection chamber , excavation of earth pit, supply and filling of salt/ coke/ charcoal layer, supply of civil material, back filling and covering with GI cover cap.Supply and install of Earth electrode using 100 mm dia, Medium duty, 3 meter long, minimum galvanization thickness shall be average 100 micron and minimum mass shall be 720 gm/sq.m. earth pipe with GI cover cap, earth strip with bolts, nut & washer, including preparation of concrete chamber as inspection chamber , excavation of earth pit, supply and filling of salt/ coke/ charcoal layer, supply of civil material, back filling and covering with GI cover cap. 500 x 500 mm, 6mm THK, removable cast iron cover for earth pit. |
| 34 | 50 X 6 MM GI Flat laying: Laying of 50 X 6 MM GI earth strips ,suitably cut, bent, formed, layed and fixed, buried in ground or embedded in concrete, clamped to structure / equipment foundations, racks, walls, roofs, trenches etc. as required including excavation and filling of earth, chipping and remaking of concrete surface,applying of bitumin paint & hessian tape on underground joints & cold zinc spray on aboveground joints and necessary hardware, welding as required for connecting the earth strip and as per direction of E-i-C. |
| 35 | 25 X 6 MM GI Flat laying: Laying of 25 X 6 MM GI earth strips ,suitably cut, bent, formed, layed and fixed, buried in ground or embedded in concrete, clamped to structure / equipment foundations, racks, walls, roofs, trenches etc. as required including excavation and filling of earth, chipping and remaking of concrete surface,applying of bitumin paint & hessian tape on underground joints & cold zinc spray on aboveground joints and necessary hardware, welding as required for connecting the earth strip and as per direction of E-i-C. |
| 36 | 16 mm Dia Hot Dip Galvanised GI Wire Rop: Laying of 16 mm Dia Hot Dip Galvanised GI rope ,suitably cut, bent, formed, layed and fixed, buried in ground or embedded in concrete, clamped to structure / equipment foundations, racks, walls, roofs, trenches etc. as required including excavation and filling of earth, chipping and remaking of concrete surface,proper lugging of the end points of the wire rope ,as required for connection and as per direction of E-i-C. |
| 37 | Supply and installation of cable markers for buried HV/MV cable at the interval of 30M, at every bend & at every cable joint location and associated materials including engraving \\"BURIED ELECTRIC CABLES HT/LT\\" along with complete support and foundation and painting and as per directions of Engineer-in-charge and as per specification in Annexure-F. |
| 38 | Cable laying 1C X 630 Sqmm, AL, XLPE, Armoured: The Contractor scope includes, laying of cables (using cable pulling by motorized winch with torque limits),installation,testing & commissioning of different voltage grade and types of the following cables in ready trays/trenches/racks/underground/buried/ cable duct bank / road crossing / supported on structure/pull through pipes,clamping to column wall or structure using GI spacers and saddles (at an interval of 300 mm),Installation & supply of anodise Aluminium / Stainless steel tags for overhead & buried cables respectively. Installation & supply of G.I saddles & G.I Clamps, cable tie, clamping of cables on trays & necessary hardwares. Cables laid in trays shall be dressed and clamped using GI Clamps at every 750 mm. Scope shall include opening the RCC slabs/Covers from Cable Trenches before laying and replacing them after laying. including supply and fixing of stainless steel/aluminium/lead strip number tags, cable ferrules, certified trefoil clamps of non-magnetic material for 1C cables, cable tie, etc.The cable laying work shall include transportation of cable drums from owner's issue point to the place of installation by contractor's own lifting & transportation arrangement, unpacking, cable cutting as per actual length measurement & cable schedule/cable drum schedule, return of unused cable/drums to the owner's store & removal of empty drum to Owner's Scrap Yard, including all labour and materials complete and as per directions of Engineer-in-charge.Cable Details : 33KV/33KV Unearthed Power Cables, Stranded aluminium conductor, XLPE insulated, extruded PVC inner sheathed, armoured & extruded FRLS PVC outer sheathed, conductor and insulation screened 1C X 630 Sqmm, AL, XLPE, Armoured, PVC FRLS |
| 39 | Cable laying 4C X 300 Sqmm, AL, XLPE, Armoured: The Contractor scope includes, laying of cables (using cable pulling by motorized winch with torque limits),installation,testing & commissioning of different voltage grade and types of the following cables in ready trays/trenches/racks/underground/buried/ cable duct bank / road crossing / supported on structure/pull through pipes,clamping to column wall or structure using GI spacers and saddles (at an interval of 300 mm),Installation & supply of anodise Aluminium / Stainless steel tags for overhead & buried cables respectively. Installation & supply of G.I saddles & G.I Clamps, cable tie, clamping of cables on trays & necessary hardwares. Cables laid in trays shall be dressed and clamped using GI Clamps at every 750 mm. Scope shall include opening the RCC slabs/Covers from Cable Trenches before laying and replacing them after laying. including supply and fixing of stainless steel/aluminium/lead strip number tags, cable ferrules, certified trefoil clamps of non-magnetic material for 1C cables, cable tie, etc.The cable laying work shall include transportation of cable drums from owner's issue point to the place of installation by contractor's own lifting & transportation arrangement, unpacking, cable cutting as per actual length measurement & cable schedule/cable drum schedule, return of unused cable/drums to the owner's store & removal of empty drum to Owner's Scrap Yard, including all labour and materials complete and as per directions of Engineer-in-charge.Cable Details : MEDIUM VOLTAGE POWER CABLES- ALUMINIUM1.1KV Grade Power Cable, Stranded Aluminium conductor, XLPE insulated, extruded PVC inner sheathed, armoured & extruded FRLS PVC outer sheathed 4C x 300 Sqmm, AL, XLPE, Armoured, PVC FRLS |
| 40 | Cable laying 4C X 25 Sqmm, AL, XLPE, Armoured: The Contractor scope includes, laying of cables (using cable pulling by motorized winch with torque limits),installation,testing & commissioning of different voltage grade and types of the following cables in ready trays/trenches/racks/underground/buried/ cable duct bank / road crossing / supported on structure/pull through pipes,clamping to column wall or structure using GI spacers and saddles (at an interval of 300 mm),Installation & supply of anodise Aluminium / Stainless steel tags for overhead & buried cables respectively. Installation & supply of G.I saddles & G.I Clamps, cable tie, clamping of cables on trays & necessary hardwares. Cables laid in trays shall be dressed and clamped using GI Clamps at every 750 mm. Scope shall include opening the RCC slabs/Covers from Cable Trenches before laying and replacing them after laying. including supply and fixing of stainless steel/aluminium/lead strip number tags, cable ferrules, certified trefoil clamps of non-magnetic material for 1C cables, cable tie, etc.The cable laying work shall include transportation of cable drums from owner's issue point to the place of installation by contractor's own lifting & transportation arrangement, unpacking, cable cutting as per actual length measurement & cable schedule/cable drum schedule, return of unused cable/drums to the owner's store & removal of empty drum to Owner's Scrap Yard, including all labour and materials complete and as per directions of Engineer-in-charge.Cable Details : MEDIUM VOLTAGE POWER CABLES- ALUMINIUM1.1KV Grade Power Cable, Stranded Aluminium conductor, XLPE insulated, extruded PVC inner sheathed, armoured & extruded FRLS PVC outer sheathed 4C X 25 Sqmm, AL, XLPE, Armoured, PVC FRLS |
| 41 | Cable laying 4C X 95 Sqmm, AL, XLPE, Armoured: The Contractor scope includes, laying of cables (using cable pulling by motorized winch with torque limits),installation,testing & commissioning of different voltage grade and types of the following cables in ready trays/trenches/racks/underground/buried/ cable duct bank / road crossing / supported on structure/pull through pipes,clamping to column wall or structure using GI spacers and saddles (at an interval of 300 mm),Installation & supply of anodise Aluminium / Stainless steel tags for overhead & buried cables respectively. Installation & supply of G.I saddles & G.I Clamps, cable tie, clamping of cables on trays & necessary hardwares. Cables laid in trays shall be dressed and clamped using GI Clamps at every 750 mm. Scope shall include opening the RCC slabs/Covers from Cable Trenches before laying and replacing them after laying. including supply and fixing of stainless steel/aluminium/lead strip number tags, cable ferrules, certified trefoil clamps of non-magnetic material for 1C cables, cable tie, etc.The cable laying work shall include transportation of cable drums from owner's issue point to the place of installation by contractor's own lifting & transportation arrangement, unpacking, cable cutting as per actual length measurement & cable schedule/cable drum schedule, return of unused cable/drums to the owner's store & removal of empty drum to Owner's Scrap Yard, including all labour and materials complete and as per directions of Engineer-in-charge.Cable Details : MEDIUM VOLTAGE POWER CABLES- ALUMINIUM1.1KV Grade Power Cable, Stranded Aluminium conductor, XLPE insulated, extruded PVC inner sheathed, armoured & extruded FRLS PVC outer sheathed 4C X 95 Sqmm, AL, XLPE, Armoured, PVC FRLS |
| 42 | Cable laying 3C X 2.5 Sqmm, Cu, XLPE, Armoured: The Contractor scope includes, laying of cables (using cable pulling by motorized winch with torque limits),installation,testing & commissioning of different voltage grade and types of the following cables in ready trays/trenches/racks/underground/buried/ cable duct bank / road crossing / supported on structure/pull through pipes,clamping to column wall or structure using GI spacers and saddles (at an interval of 300 mm),Installation & supply of anodise Aluminium / Stainless steel tags for overhead & buried cables respectively. Installation & supply of G.I saddles & G.I Clamps, cable tie, clamping of cables on trays & necessary hardwares. Cables laid in trays shall be dressed and clamped using GI Clamps at every 750 mm. Scope shall include opening the RCC slabs/Covers from Cable Trenches before laying and replacing them after laying. including supply and fixing of stainless steel/aluminium/lead strip number tags, cable ferrules, certified trefoil clamps of non-magnetic material for 1C cables, cable tie, etc.The cable laying work shall include transportation of cable drums from owner's issue point to the place of installation by contractor's own lifting & transportation arrangement, unpacking, cable cutting as per actual length measurement & cable schedule/cable drum schedule, return of unused cable/drums to the owner's store & removal of empty drum to Owner's Scrap Yard, including all labour and materials complete and as per directions of Engineer-in-charge.Cable Details : MEDIUM VOLTAGE POWER CABLES- ALUMINIUM1.1KV Grade Power Cable, Stranded Copper conductor, XLPE insulated, extruded PVC inner sheathed, armoured & extruded FRLS PVC outer sheathed 3C X 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS |
| 43 | Laying of 150(W) X 100(H) mm Cable Tray: Installation and laying of 150(W) X 100(H) mm cable trays including transportation from store/yard to site at the place of installation, unpacking,cable trays, fittings, covers,.etc. complete with necessary splice plates,Cable Tray Hold Down Clamps, with required bolt, nut & washers and as per directions of Engineer-in-Charge |
| 44 | Supply and wiring of light point with 2.5 sq.mm PVC insulated , FR, copper conductor wire in surface/ recessed 25 mm dia GI/PVC/ metsec conduit including all accessories on surface or in recess, including supply and fixing of 5A one way switch/ GI box including circuit wiring, earthing of light fixture with 2.5 sqmm PVC insulated FR, copper wire etc. as required. The above scope includes cutting, chasing of wall and filling the chases with mortar and making good finish as required. Wire and switch shall also form part of point wiring and will not be paid separately. |
| 45 | Supply and wiring of light point with 4 sq.mm PVC insulated , FR, copper conductor wire in surface/ recessed 25 mm dia GI/PVC/ metsec conduit including all accessories on surface or in recess, including supply and fixing of 5A one way switch/ GI box including circuit wiring, earthing of light fixture with 2.5 sqmm PVC insulated FR, copper wire etc. as required. The above scope includes cutting, chasing of wall and filling the chases with mortar and making good finish as required. Wire and switch shall also form part of point wiring and will not be paid separately. |
| 46 | Each alphabet/character above 2 inch: Letter painting and marking of all buses of switchboards, all incomers, bus couplers, outgoings with details of Tag No, feeder rating in KW/Amp, sending end source, in the front of the panels and bus bar, panel nos.etc. on the rear side of the panels for all switchboards, all other substation equipment viz.transformers, capacitors, neutral grounding resistors, VFD panels, other panels, tray segment etc for equipment housed in electrical substations including supply of all material such as stickers, enamel paints, stencil, etc including supply of all labour, materials as per the specification of this tender and directions of Engineer-in-Charge. Each alphabet/character above 2 inch and Upto 4 inch in height/length - with fluorescent paint |
| 47 | Excavation and back filling of trenches for directlly burried cables and earth conductor in all type of soil except rock, for a max. depth of 1.5 M shoring, shuttering and dewatering / deoiling using pneumatic pump (if necessary) including consolidation and disposal of surplus earth outside refinery or as per direction of Engineering-in-charge, including all labour and materials complete. |
| 48 | Supply and filling /spreading of approved fine river sand in burried cable trenches and in RCC cable trenches including removal of RCC trench covers/slab, refixing of RCC trench Covers/Slabs after filling/spreading the sand, including all labour and materials complete as per directions of Engineerin-in-charge. |
| 49 | Supply and spreading / laying of second class bricks of 75 mm thickness in RCC cable trenches (for cable protection) including removal of RCC trench covers/slab from RCC trench, refixing of RCC trench covers/Slab after laying of bricks, if required, including all labour and materials complete and as per directions of Engineerin-in-charge |
| 50 | Supply and laying plain cement concrete for all depths below and up to plinth level in foundations including tamping, ramming, vibrating, cutting, shuttering etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed, including supply of all materials and all complete for concrete of M-15 grade with 20 mm and down size graded crushed stone aggregates, including all labour and materials and directions of Engineer-in-charge. |
| 51 | Housekeeping/upkeepment/readiness etc. of site (minimum 2numbers of semi skilled and 6 nos of unskilled manpowers per day basis) for manual jobs, special requirements and as per direction of E-i-C. |
| 52 | ITC of 33kV termination Kit: Installation, testing and commissioning of 33kV Termination kit of 630, 500 and 400sqmm single core cable through OEM (M/s NKT) /OEM authorised representative and as per direction of E-i-C. |
| 53 | 33/33 KV, 1C X 630 sq mmTermination Kit: Supply of Heat shrinkable HV Cable termination kit (UE) and termination of XLPE insulated HV cables of following sizes of cables including cutting and stripping of cable insulation, fixing compression type lugs and crimping the lugs onto the conductor, executing termination using Heat Shrinkable Termination Kit , restoration of the insulation,including drilling of suitable holes in equipment for fixing purpose, connection of leads, clamping, including anti tracking compound, installation and supply of ferrules, single core cable fixing clamps, cable ties, cable Aluminium tags, clamping of cores and earthing of armour, including all labour and materials complete and as per direction of Engineer-in-charge.This will also include provision of additional supports if required, for proper dressing and support of cable. The contractor to also arrange suitable Stop Plugs for unused entry, if required. The cost for supply of suitable crimping type, heavy duty, long barrel type Alluminium / Copper lugs and bimetallic strip (if required) shall be included in termination, no separate payment shall be made for cable lugs & bimetallic strips. All supplied lugs shall be of heavy duty long barrel type.Cable Size : 33/33 KV, 1C X 630 Sqmm |
| 54 | Cable termination LT upto 40mm: Termination of cable having outer diameter upto 40mm; CABLETERMINATION :(Common specification for this & same category of items below) :Termination ofarmoured power cables (Typically PVC/XLPE insulated up to 1100 V grade). Jobincludes earthing the cable armour, connecting to the terminals, supply and marking of upto 1100V 3/3.5/ 4 core of size wire number ferrules/ cable tags (ss/ aluminium/ lead strip minimum 2 mm thick and 20 mm wide at the termination point), drilling inequipment,removal, cutting , fixing of gland plate, fixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable-cores, consumable items like Crimping paste, insulationTapes, Including Supply of cable WP GLAND and LUGS etc. complete, including all labour and materials complete, as per approved drawings, specifications of this tender and directions of EIC. Miminum 3 workers (1 high skilled and 2 semi skilled workers) will be enaged by the vendor to complete the job |
| 55 | Cable termination LT above 40mm: Termination of cable having outer diameter above 40mm; CABLETERMINATION :(Common specification for this & same category of items below) :Termination ofarmoured power cables (Typically PVC/XLPE insulated up to 1100 V grade). Jobincludes earthing the cable armour, connecting to the terminals, supply and marking of upto 1100V 3/3.5/ 4 core of size wire number ferrules/ cable tags (ss/ aluminium/ lead strip minimum 2 mm thick and 20 mm wide at the termination point), drilling inequipment,removal, cutting , fixing of gland plate, fixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable-cores, consumable items like Crimping paste, insulationTapes, Including Supply of cable WP GLAND and LUGS etc. complete, including all labour and materials complete, as per approved drawings, specifications of this tender and directions of EIC. Miminum 3 workers (1 high skilled and 2 semi skilled workers) will be enaged by the vendor to complete the job |
| 56 | Structural Steel Works: Supply, Fabrication, galvanising and installation of various sizes steel for supports, brackets for miscellaneous electrical equipment, base frames, support for switchgear, hangers, risers, clamps etc. for miscellaneous electrical equipment / items, cable and cable tray supports with rolled MS sections, pipes, plates, strip etc., including Blasting,supply of Paints & Painting including consumables,welding, bolting, rivetting, supply of necessary anchor bolts and grouting etc., including breaking walls, floors etc. for structures as required, including supply of all G.I hardware materials, including all labour and materials, complete as per approved drawings, specification of this tender and directions of Engineer-In-charge. (Any item weighing up to 1 kg or less shall neither be measured nor paid. |
| 57 | Horizontal boring works: Making horizontal bore under the WBM etc of the roads : Makinghorizontal bore under the WBM of the roads etc. manually or bymachine for laying of upto 100 mm NB GI/ RCC pipes, excavatingthe side approach to facilitate boring, backfilling the sameafter completion of works including supply of tools ,tackles,equipment etc.personal protective equipment to completethe job complete as required, excluding the supply of GI pipeas directed by E-i-C. |
| 58 | F & I of GI Pipe 100NB: Fabrication and installation of of 100 mm dia,class B GI pipes/sleeves for cable protection, fixed on steel, concrete orsimilar structure, in trenches, ready to be buried in concreteincluding cutting, bending, grinding, threading and similarworks, supply & fixing of required GI fastners, clamps, smalliron structures, spacers, cleats, plug, bushings, sealingcompound/ material etc., cutting and remaking of concretesurface including supply of civil material, all labour andmaterials complete as per approved drawings, specification ofthis tender and directions of Engineer-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender