Tender For Repair/Replacement Of Internal Wiring Of Mh, Mdc, Echs, Mh Officer Mess Otm Area And Repair/Maint Of Fire Fighting Sys-Tem, Various Types Of Pumps, Motor, Electric Panel At Dana-Pur Under Ge Danapur Cantt
Tender Value
45 Lakhs
Estimated cost
Bid Submission
23 Jul 2026
14 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Patna → Bihar
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Replacement Of Internal Wiring Of Mh, Mdc, Echs, Mh Officer Mess Otm Area And Repair/Maint Of Fire Fighting Sys-Tem, Various Types Of Pumps, Motor, Electric Panel At Dana-Pur Under Ge Danapur Cantt
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully copper / aluminium point wiring (light, fan, switch,socket or power, Bell & Two way point) complete with fitting such as switches, sockets, ceiling rose,sketch light fittings etc, and making good the disturbed surface of walls and floors etc complete all as specified and directed. |
| 2 | Taking down carefully main switches DB's/ MCB DB's and making good the disturbed surfaces of walls etc complete all as specified and directed. |
| 3 | Taking down carefully copper / aluminium sub main wiring including teak wood batten / conduit and making good the disturbed surface of walls as directed. |
| 4 | M & L for Point wiring with PVC insulated PVC unsheathed electric FRLS cable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area in & including non metallic rigid PVC conduit ISI marked medium grade not less than 20 mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of wall (cutting except on ceiling for fan point only, on ceiling PVC conduit on surface will be used) & 1.5 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs excluding MS boxes for mounting switches, sockets, fan regulators etc for one light/fan point controlled by one switch complete all as specified and as directed. |
| 5 | Same as item No 4 above but one bell point controlled by one bell Push. |
| 6 | Same as item No 4 above but one 5 Amps socket out let point controlled by one switch on same board with other switches. |
| 7 | Same as item No 4 above but one 5 Amps socket out let point on independent board controlled by one switch. |
| 8 | Same as item No 4 above but wiring with 2.5 Sqmm single core copper conductor for one socket out let 15/16 amps point on the independent board. |
| 9 | Same as item No 4 above but wiring with 4 Sqmm single core copper conductor for one socket out let 15/16 amps point on the independent board. |
| 10 | M & L for Point wiring with PVC insulated PVC unsheathed electric FRLS cable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area drawn in existing concealed conduit and 1.5 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs including MS boxes for mounting switches, sockets, fan regulators etc for one light/fan point controlled by one switch complete all as specified and as directed. |
| 11 | Same as item No 10 above but one 5 Amps socket out let point controlled by one switch on same board with other switches. |
| 12 | Same as item No 10 above but one 5 Amps socket out let point on independent board controlled by one switch. |
| 13 | Same as item No 10 above but wiring with 2.5 Sqmm single core copper conductor for one socket out let 15/16 amps point on the independent board. |
| 14 | Supply and fixing switch piano flush button single pole one way 5 amps, 240 Volts complete all as specified and directed. |
| 15 | Supply and fixing socket outlet flush type 5 Amps, 5 pin, 240 Volts complete all as specified and directed. |
| 16 | Supply and fixing switch piano flush button single pole one way 15 Amp 240 volt complete all as specified and directed. |
| 17 | Supply and fixing socket outlet flush type multipurpose 2 in 1, 3 pin 5 and 15 Amp, 240 volts complete all as specified and directed. |
| 18 | Supply and fixing bell push single pole, 6 Amps, 240 Volts, flush type complete all as specified and directed. |
| 19 | Supply and fixing Ceiling rose surface bakelite 63.5 mm dia three terminal complete all as specified and directed. |
| 20 | Supply and fixing for batten/angular fittings complete all as specified and directed. |
| 21 | Supply and fixing for electronic Fan regulator socket type suitable for BLDC fan complete all as specified and directed. |
| 22 | Supply and fixing in repair Bell, AC 240 Volts,single pole,ding dong type complete all as specified and directed. |
| 23 | Supply and fixing in repair white/color finished single mounting modular plates with inner & outer cover suitable for housing modular accessories suitable for one module box complete all as specified and directed. |
| 24 | Same as item No 23 above but suitable for 2 modules |
| 25 | Same as item No 23 above but suitable for 3 modules |
| 26 | Same as item No 23 above but suitable for 4 modules |
| 27 | Same as item No 23 above but suitable for 6 modules |
| 28 | Same as item No 23 above but suitable for 8 modules |
| 29 | S&F sheet metal boxes concealed in wall suitable for housing modular accessories for 1 or 2 modules complete all as specified and directed. |
| 30 | Same as item No 29 above but suitable for 3 modules |
| 31 | Same as item No 29 above but suitable for 4 modules |
| 32 | Same as item No 29 above but suitable for 8 modules |
| 33 | Supply and fixing in repair modular Switch 6 Amps single pole, one way complete all as specified and directed . |
| 34 | Supply and fixing in repair Modular Socket outlet, multi purpose, 5 Pin 6 Amps flush type complete all as specified and directed . |
| 35 | Supply and fixing in repair Modular Bell push flush type,6 Amps fixed complete all as specified and directed |
| 36 | Supply and fixing in repair Modular Socket outlet, multi purpose, 6 pin 16 Amps universal socket complete all as specified and directed . |
| 37 | Supply and fixing in repair Modular Switch 16 Amps single pole, one way complete all as specified and directed . |
| 38 | Supply and fixing in repair modular fan regulator of four step type suitable for BLDC fan complete all as specified and directed. |
| 39 | S & F in replacement of switch piano flush button single pole one way 5/6 Amp 240 volt complete all as specified and directed. |
| 40 | S & F in replacement of switch piano flush button single pole one way 15/16 Amp 240 volt complete all as specified and directed. |
| 41 | S&F in replacement of socket outlet flush type multipurpose 2 in 1, 3 pin 5/6 and 15/16 Amp, 230 volts complete all as specified and directed. |
| 42 | S&F in replacement of unservicable socket outlet flush type multipurpose 2 in 1,3 pin 5 .Amp, 230 volts complete all as specified and directed. |
| 43 | S&F in replacement of switch socket outlet combination flush type multipurpose 2 in 1, 3 pin 5 and 15 Amp, 230 volts complete all as specified and directed. |
| 44 | S&F in replacement of switch socket outlet combination flush type with box multipurpose 2 in 1, 3 pin 5 and 15 Amp, 230 volts complete all as specified and directed. |
| 45 | S&F in replacement bell push single pole one way 5 Amp, 240 volt flush type complete all as specified and directed. |
| 46 | Supply and fixing in repair plastic laminated bakelite sheet cover of Hylam brand 2.8 mm thick including cutting holes for switches, sockets etc as pre requirement including fixing with machine screws and washer for size 250 mm X 300mm complete all as specifed and directed. |
| 47 | Same as item No 46 above but of size 200mm X 250 mm |
| 48 | Same as item No 46 above but of size 200mm X 150 mm |
| 49 | Same as item No 46 above but of size 150mm X 100 mm |
| 50 | Same as item No 46 above but of size 100mm X 100 mm |
| 51 | Supply and fixing in repair Cast Iron/ pressed steel terminal rectangular sunken boxes 60 mm deep for mounting, switches, sockets, fan regulator, etc. with 3mm thick plastic laminated sheet cover of size 250 x 300 x 50 mm complete all as specified and directed. |
| 52 | Same as item No 51 above but of size 200mm X 250 mm |
| 53 | Same as item No 51 above but of size 200mm X 150 mm |
| 54 | Same as item No 51 above but of size 150mm X 150 mm |
| 55 | Same as item No 51 above but of size 100mm X 100 mm |
| 56 | Supply and fix vertical TPN distribution board 4 way suitable for 160 Amp MCCB with 160 Amp MCCB as incomer double door steel sheet, powder coated, fitted with bus bar, din rail, neutral link , Earth bar complete all as specified directed. |
| 57 | S&F sheet metal enclosure for MCB DB double door type, triple pole and neutral 4 way 415Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed. |
| 58 | S&F sheet metal enclosure for MCB DB double door type, single pole and neutral 12 way 240 Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed. |
| 59 | S&F sheet metal enclosure for MCB DB double door type, single pole and neutral 8 way 240 Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed. |
| 60 | Supply and fixing MCB SPN 40 to 63 amps 10 KA ,C-series including connection with suitable size aluminium / copper lugs complete all as specified and directed. |
| 61 | Supply and fixing MCB SP 240 volts 5 to 32 Amps, 10 KA breaking capacity, 'C' type including connection with suitable size aluminium / copper lugs complete all as specified and directed. |
| 62 | Supply and fixing MCB TPN 50 to 63 amps 10 KA ,C-series including connection with suitable size aluminium / copper lugs complete all as specified and directed. |
| 63 | Supply and fixing MCB TPN 100 amps 10 KA ,C-series including connection with suitable size aluminium / copper lugs complete all as specified and directed. |
| 64 | Supply and Fixing wall/surface mounting luminaires integrated LED Batten 18/20/22 W, 6000 K,>100 lumens/watt , 230V with extruded Aluminium housing 4 feet long with frosted PMMA/PC diffuser & integrated electronic driver complete including Electrical connection with PVC three core copper flexible wire & all necessary fixing arrangements complete all as specified and directed. |
| 65 | Supply and fixing wall/surface mounting luminaires (Mirror Light) integrated LED Batten (2 feet) 10/12 W, 6500 K, 230V ,100 lumens/watt,with PVC housing & integrated electronic driver complete including Electrical connection with PVC three core copper flexible wire & all necessary fixing arrngements complete all as specified and directed. |
| 66 | S&F in repairs of surface/recess type square/round LED 12W downlighter all as specified and directed. |
| 67 | Supply and fix wall mounting fans 400 mm (white) string controlled oscillating type including provn of flexible three core cable from ceiling rose to terminal for making connection, fitting on wall including all necessary fixing accessories complete all as specified and directed. |
| 68 | Supply, fixing and testing of ceiling fan 1200 mm sweep, heavy duty, single phase, AC, 230 Volts, 50Hz, BEE 5 star rating, ISI marked with down rod, canopy, blades, BLDC motor etc and connecting up including complete connection from ceiling rose to fan including writing of MES Number with synthetic enamel paint complete all as specified and as directed including taking down old unsv one and deposit in MES store for BER. |
| 69 | Supply and fix electric water heater,storage type with stainless steel inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate,NRV, connection piece etc. complete all as specified and directed. |
| 70 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm complete all as specified and directed. |
| 71 | S&F recessed mounting fitting 36/42 watt ultra modern design architectural LED luminaire which provides soft-light and glare free symmetrical illumination suitable for Armstrong / Grid Ceiling including LED driver and 36/42 watt lamp incl all accessories complete all as specified and directed. |
| 72 | Supply and fixing LED light fitting for bldg security lighting energy saving & environmental friendly long life versatile pressure die-cast housing with individual high power LED as light source and lens embedded PC cover of capacity 35 watt >100 lum/watt , 240 volts AC 50 Hz , IK 07 and IP 66 protection suitable for 40/25 mm dia GI pipe bracket complete all as specified and directed. |
| 73 | M & L for security wall light bracket made out of GI pipe light grade 40 mm dia 0.9 metre length bent to shape and reduced to required size at top upto 1.5 metre length by cutting, welding and well finishing including MS clamp of flat iron of size 40x6 mm of suitable length 2 sets complete with drilling, hole, fixing with nuts bolts and washers including painted with two coats of aluminium paints over a coat of red oxide primer including dismantling one complete all as specified and directed. |
| 74 | S&F in replacement sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 4 sqmm nominal cross sectional area and one run of 4 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 20mm dia 'medium grade' PVC concealed conduits (ISI marked) and fittings complete all as specified and directed.NOTE:- One unit length shall measured as two run of main wire and one run of conduit & earth wire. |
| 75 | S&F in replacement sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 6 sqmm nominal cross sectional area and one run of 6 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 20mm dia 'medium grade' PVC concealed conduits (ISI marked) and fittings complete all as specified and directed.NOTE:- One unit length shall measured as two run of main wire and one run of conduit & earth wire. |
| 76 | S&F in replacement sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 4 sqmm nominal cross sectional area and one run of 4 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn into existing conduit complete all as specified and directed.NOTE:- One unit length shall measured as two run of main wire and one run of earth wire. |
| 77 | Supply and fixing in replacement for 1.5 sqmm single core copper,multistandard PVC insulated (FRLS) unsheathed, cable 1100 volts grade complete all as specified and directed. |
| 78 | Supply and fixing in replacement for 2.5 sqmm single core copper,multistandard PVC insulated (FRLS) unsheathed, cable 1100 volts grade complete all as specified and directed. |
| 79 | Supply and fixing in replacement for 4 sqmm single core copper,multistandard PVC insulated (FRLS) unsheathed, cable 1100 volts grade complete all as specified and directed. |
| 80 | Supply and fixing in replacement for 6 sqmm single core copper,multistandard PVC insulated (FRLS) unsheathed, cable 1100 volts grade complete all as specified and directed. |
| 81 | S&F in replacement 1100V grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection ,one twin core cable flat or circular stranded 10 sqmm aluminiuam conductor complete all as specified and as directed. |
| 82 | S&F in replacement service cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection ,one twin core cable flat or circular stranded 4 sqmm aluminiuam conductor complete all as specified and directed. |
| 83 | M&L for Rigid non metallic PVC conduit ISI marked, medium grade, inclusive of all fitting such as tees,bends. Junction boxes, elbows saddles. Pipe hooks,couples and lock outs etc 25 mm external dia, fixed on surface mounted and making good disturbed surfaces in repairs complete all as specified and directed. |
| 84 | M&L for Rigid non metallic PVC casing caping ISI marked, medium grade,not less than 25 mm base size inclusive of all fitting such as tees,bends. Junction boxes, elbows saddles hooks,couples and lock outs etc fixed on surface mounted and making good disturbed surfaces in repairs complete all as specified and directed. |
| 85 | Supply & fixing in repair AC Box, plug and socket, with and including single pole MCB 32 Amps 240 volts fixed in repairs complete all as specified and directed. |
| 86 | Supply and fixing in repair of Earthing to panel with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to galvanised earth lead wire 4.0mm dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead strip protected by GI pipe 40 mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and directed. |
| 87 | Dismantling of burnt electric motors, includes removal of burnt/damaged winding, cleaning of stator core, insulation testing, rewinding with new copper winding of required gauge, varnishing, baking, reassembling, testing and commissioning of following capacities of motors:- |
| 88 | 50 HP |
| 89 | 20 HP |
| 90 | 10/12.5 HP |
| 91 | Overhauling of electric motor includes each part cleaning properly, oiling, greasing with replacing bearing, bushes, oil seal, gland packing set and re-assembling of pump set all as specified and directed and making connection with proper size of lugs, nuts bolts including cleaning , scraping out old rubbed paint / rust & applying two coat of rubber synthetic paint ( first class ) by spray painting machine over a coat of primer including testing and commissioning of following capacities of motors:- |
| 92 | 50 HP |
| 93 | 20 HP |
| 94 | 10/12.5 HP |
| 95 | M&L for routine servicing of 50HP deisel engine including oil change, filter replacement, injector cleaning, cooling system check, inspection, trial run and labour complete all as specified and directed. |
| 96 | Overhauling of 50HP deisel engine including dismantling, cleaning, inspection, replacement of gaskets and consumables, piston/crank/valve servicing, reassembly, testing and commissioning complete all as specified and directed. |
| 97 | M&L for pressure pump 01 HP, single phase Including all accessories required for proper functioning of the system as per site requirement complete all as specified and directed. |
| 98 | S & F in repair rubber star packing of motor & pump of existing size and type including resetting alignment of the pump sets of following capacities:- |
| 99 | 10 HP/12.5 HP |
| 100 | 20 HP |
| 101 | 50 HP |
| 102 | Servicing, dismantling inspection, cleaning, replacement of worn-out parts such as diaphragm, NRV, Valves, seals and reassembly, testing and commissioning of existing Altoch chemical dosing pump complete as required for proper functioning. |
| 103 | M&L for Servicing of existing 0.5 HP Chlorine Mixing motor Including dismantling, cleaning, inspection of bearing, greasing, checking of windings, tightening of electrical connections, minor repaires, reassembly, alighnment with shaft, testing and commissioning complete as required for proper operation. |
| 104 | M&L for Greasing of electric motor, including removal of grease nipple caps , injection of fresh grease, wiping excess, refixing caps and ensuring smooth rotation complete. |
| 105 | 10 HP/12.5 HP |
| 106 | 20 HP |
| 107 | 50 HP |
| 108 | Taking out submersible pump of 62 / 72 HP capacity including motor from bore well by disconnecting all electric / water connections dismantling of motor and pump for repair including transportation from work site to workshop and back, lowering of pump set, connecting and testing complete all as specified and directed. |
| 109 | M&L for opening of submersible motor of 62 / 72 HP capacity and taking out the rotor from the body and cutting the burnt coils / winding, cleaning the starter slots properly by using cleaning material and re-winding / reassembling the same including replacement of parts/components complete including cleaning, scraping out old rubbed paint / rust & appling two coat of rubber synthetic paint (first class) by spray painting machine over a coat of primer of any capacity of motor complete all as specified and directed. Note:- Replacement of parts / components shall be measured and paid separately under respective item of Schedule 'A' as supply only. |
| 110 | M&L for Lath work including all materials as required for the following items/components of motor of 62 / 72 HP capacity complete as under :- (a) Making the strip on rotor including pressing the core of rotor and polishing the shaft. (b) Making the proper size of motor cover (housing) including welding etc. (c) Re-metaling of thrust plate and replacement of ebonite sheets complete. |
| 111 | Supply only nut bolts and Washers Suitable for 62/72 HP Motor as per sample complete all as specified and directed.( Full set) |
| 112 | Supply only Bushes/Shaft Sleeves Suitable for 62/72 HP Motor as per sample complete all as specified and directed. |
| 113 | Supply only Gland packing, Gaskets, oil seal Suitable for 62/72 HP Motor as per sample complete all as specified and directed. |
| 114 | S&F 3 core x 35 Sqmm Copper Flat Submersible Cable (ISI marked, PVC/XLPE insulated, Suitable upto 1100V) complete all as specified and directed. |
| 115 | S & F in repair replacement of Direct-On-Line (DOL) Starter suitable for 20 HP, 3-phase, 415V, electric motor, complete with heavy-duty contactor (AC-3 duty), thermal overload relay, ON/OFF push button control, indicator lamps, voltmeter with selector switch, ammeter with CTs and selector switch, housed in a powder-coated MS enclosure with necessary internal wiring and connections, providing short-circuit and overload protection, duly tested and ready for operation complete all as specified and directed. |
| 116 | S & F in repair replacement of of Direct-On-Line (DOL) Starter suitable for 10 HP, 3-phase, 415V, electric motor, complete with heavy-duty contactor (AC-3 duty), thermal overload relay, ON/OFF push button control, indicator lamps, voltmeter with selector switch, ammeter with CTs and selector switch, housed in a powder-coated MS enclosure with necessary internal wiring and connections, providing short-circuit and overload protection, duly tested and ready for operation complete all as specified and directed. |
| 117 | S&F in replacement of ML-4 Submersible Star-Delta Starter Panel suitable for operation of 62 HP, 3-phase, 415V AC submersible pump motor, complete with heavy-duty power contactors (Main, Star & Delta) of AC-3 duty, thermal overload relay, auto/manual selector switch, ON/OFF push buttons, ammeter with CTs, voltmeter with selector switch, indicator lamps, suitably rated capacitor for power factor improvement, incoming MCCB 200A, 4-pole, 36 KA with rotary operating handle, outgoing MCCB 125A, 4-pole, 25/36 KA, all housed in powder-coated MS sheet enclosure with internal copper wiring, earthing connections, duly tested and ready for operation complete all as specified and directed. |
| 118 | S&F in replacement of 6\\" (150 mm) dia column pipe for borewell installation, heavy duty MS/ERW pipe of ISI mark, minimum wall thickness 5–6 mm, length 3 m/5 m with threaded/flanged ends and suitable couplings, including welding, threading, alignment, lowering in borewell, jointing with nuts, bolts, gaskets, and painting with anti-corrosive primer and two coats of synthetic enamel paint, complete all as specified and directed. |
| 119 | S&F in replacement of ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 200 Amps including all fixing arrangement complete all as specified and directed. |
| 120 | S&F in replacement of Pressure gauge 0-150 LBS/in 2 / 0 to 10 Kg/cm2 ISI marked complete all as specified and directed. |
| 121 | S & F in repair of Start/Stop push button heavy duty type complete all as specified and directed. |
| 122 | M&L for replacement of Voltmeter 96 mm x 96 mm, range 0-500 Volts digital type complete all as specified and directed. |
| 123 | M&L for replacement of Ammeter 96 mm x 96 mm, range-0-100 Amps digital type complete all as specified and directed. |
| 124 | M&L for replacement Indication lamp (RYB) complete all as specified and directed. |
| 125 | M&L for replacement of Voltmeter selector switch for (0-500 volts) voltmeter as per sample / existing complete all as specified and directed. |
| 126 | M&L for replacement of Ammeter selector switch for (0-30 / 0-100 Amps) Ammeter as per sample / existing complete all as specified and directed. |
| 127 | S & F in repair for Checking, cleaning of Star delta starter panel including replacement of burnt cable, lugs, tightening of connectiion complete all as specified and directed of the following items :- |
| 128 | 3 pole power contactor type MNX-80Mate :- L & T /Legrand / Schneider |
| 129 | 3 pole power contactor type MNX-40Mate :- L & T /Legrand / Schneider |
| 130 | 3 pole power contactor type MNX-75Mate :- L & T /Legrand / Schneider |
| 131 | S&F in replacement of 125 Amp, 4-Pole MCCB, 415V, 36 KA breaking capacity, thermal–magnetic release with adjustable settings, complete with rotary operating handle and necessary accessories, mounted in panel board as required complete all as specified and directed. |
| 132 | S&F in replacement of 315 Amp, 4-Pole MCCB, 415V, 36 KA breaking capacity, thermal–magnetic release with adjustable settings, complete with rotary operating handle and necessary accessories, mounted in panel board as required complete all as specified and directed. |
| 133 | S&F in replacement of single phase preventer VPS-3 complete all as specified and directed. |
| 134 | S&F in replacement of 3-phase timer switch for automatic star-to-delta changeover in motor starting panels, Designed to control star contactor OFF and delta contactor ON after preset time delay, Suitable for 415V AC, industrial applications complete all as specified and directed. |
| 135 | S&F in replacement old/damaged internal wiring of electrical panel with new suitable size copper flexible cables, including removal of existing wiring, supply and fixing FRLS insulated multi-strand copper wires, proper crimping with lugs, ferruling, dressing and tying, insulation taping and termination at MCB/MCCB/contactor/relay terminals complete all as specified and directed. |
| 136 | S&F in replacement of Copper Cable Lugs with 30 mm hole size, suitable for terminating copper conductors in motor control panels, distribution boards, and power circuits. The lugs shall be made of high conductivity pure copper, tinned surface, with appropriate barrel size to fit conductor size (e.g., 16 mm² to 95 mm²), and designed for proper crimping. Suitable for M30 bolt connection. Conforming to IS 8309 / Equivalent Standards complete all as specified and directed. |
| 137 | S&F in replacement of Thermal Overload Relay, adjustable current range 60–100 A, suitable for protection of 3-phase motors against overload conditions. Wiring and connections to be done as per site requirement complete all as specified and directed. |
| 138 | S&F in replacement of Remote Water level indicator with 4 level sensor and LED display panel, Wiring and connections to be done as per site requirement complete all as specified and directed. |
| 139 | S&F in Replacement of chemical Mixing drum of required capacity, made of HDPE/FRP material, including necessary support stand, inlet, outlet, drain valve, and fixing complete all as specified and directed. |
| 140 | S&F in Replacement of Flexible plastic transparent pipe suitable for chlorine dosing, including necessary fittings such as connectors, nipples, clamps, ferrules, PTFE tape, supports and all acessories complete as required for proper operation. |
| 141 | S&F in replacement of 62HP, 415V, 3-phase submersible motor complete with matching multistage submersible pump, accessories and all necessary fittings complete all as specified and directed. |
| 142 | S&F in replacement of RRL hose reel of 20 mm dia 30 mtr long including hose box conforming to IS - 5132 complete all as specified and directed. |
| 143 | S&F in replacement of fire hydrant landing valve of approved make complete with hand wheel, flanged inlet, instantaneous outlet coupling complete all as specified and directed. |
| 144 | M&L for flushing and cleaning of existing borewell by high-pressure air compressor method including all labour, tools, tackles, compressor,hose pipes, removal of silt/sludge and testing complete all as specified and directed. |
| 145 | S&F in replacement of for 63 mm dia 15 meter long hose conforming to IS 636 complete with male and female coupling conforming to IS 903 complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 02, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysJul 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender