Housing Urban and Rular Development Government Departments Closing in 4 days TDR #56263209

Tender For Conversion Of Sp Shed To Regular Staff Quarters Including Construction Of Additional Staff Quarters And 0.125 Unit Boys Dormitory With 01 No. Warden Residence At Jnv Darbhanga (Bihar)

Issued by Government Departments · Darbhanga, Bihar
Tender Value
6.86 Crore
Estimated cost
Bid Submission
15 Jul 2026
4 days left
EMD
13.72 Lakhs
Bank guarantee accepted
Document Fee
17700
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Darbhanga → Bihar
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Conversion Of Sp Shed To Regular Staff Quarters Including Construction Of Additional Staff Quarters And 0.125 Unit Boys Dormitory With 01 No. Warden Residence At Jnv Darbhanga (Bihar)

BOQ

Name of Work:- Conversion of SP Shed to regular Staff quarters including construction of additional staff quarters and 0.125 unit Boys Dormitory with 01 no. Warden Residence at JNV Darbhanga (Bihar)
Sl. No. Item Description
1Discription of work
2STAFF QUARTERS (TYPE-II) (G+2) (13 Unit)
3Earth Work
4Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
5Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
6Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete.
7Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
8Concrete Work
9Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 coarse sand (zone-iii) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
10Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
11Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
12Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stoneaggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand,including necessary excavation,levelling & dressing & finishing the top smooth.
13Brick edging in full brick width and half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
14Reinforced Cement Concrete
15Centering and shuttering including strutting, propping etc. and removal of form for all heights :
16Foundations, footings, bases of columns, etc. for mass concrete.
17Suspended floors, roofs, landings, balconies and access platform.
18Lintels, beams, plinth beams, girders, bressumers
19Columns,Pillars, Piers, Abutments, Posts and Struts.
20Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like
21Edges of slabs and breaks in floors and walls Under 20 cm wide.
22Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
23Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500 D or more.
24Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
25Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement contentin design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
26All works upto plinth level
27Concrete of M25 grade with minimum cementcontent of 330 kg /cum
28(i) R.C.C. work in Footing
29(ii) R.C.C. work in Beam
30(iii) R.C.C. work in Columns
31All works above plinth level upto floor V level
32Concrete of M25 grade with minimum cementcontent of 330 kg /cum
33(i) R.C.C. work in Lintel
34(ii) R.C.C. work in Beam
35(iii) R.C.C. work in Columns
36(iv) R.C.C. work in Slab
37Masonry Work
38Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)
39Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
40Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in superstructure above plinth level up to floor V level in : Cement mortar 1:6 (1 cement : 6 coarse sand)
41Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
42Cladding Work
43Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
44Granite stone slab colour black, Cherry/Ruby red
45Area of slab upto 0.50 sqm
46Area of slab over 0.50 sqm
47Providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
48Granite work
49Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete.
50Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
51Providing and fixing Ist quality Glazed vitrified tiles polished finish of size 600 x 600 mm tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
52Wood and PVC Work
53Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
54Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
55Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.
56Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. Twin rubber stopper
57Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws : 30 mm thick shutters With ISI marked stainless steel butt hinges of required size Kiln seasoned and chemically treated hollock wood
58Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm.
59Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm .
60Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete.
61200 x 10mm
62150 x 10mm
63CUPBOARD / WARDROBE
64Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid board one side white color and other side of board laminted with PVC foil of minimum 14 micron thickness of approved design pasted with hot melt adhesive for cup boards, work stations and bathroom/kitchen cabinet etc. of required sizes comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/ mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel piano hinges/soft close clip on concealed hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel piano hinges/soft close clip on concealed hinges and necessary S.S screws shall be paid separately)
6518 mm thick
6625 mm thick
67Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain white color board for backing of cup boards and bathroom/kitchen cabinets etc. of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel screws etc. all as per direction of Engineer-In- Charge. (Note: stainless steel screws shall be paid separately)
686 mm thick
69Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge. 200 mm
70Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge. 100 mm for Kitchen Cabinets
71Providing and fixing stainless steel soft closing spring hinges at 0 degree hinges (hydraulic type) of approved make/brand to cupboard shutters with full threaded steel screws including making necessary recess in board and finished etc. complete as per direction of Engineer-in-charge
72Providing and fixing stainless steel soft closing heavy type telescopic drawer channels of approved make 500 mm long with screws etc. complete as per directions of Engineer- in-charge.
73Providing and fixing ready made 304 grade stainless steel Modular kitchen basket and accessories such as right angle basket (Plain Cup & Saucer, plant, Partition, Bottle rack, Thali, Cutlery) kitchen utensil basket, Dinner set basket, kitchen grain basket,Multipurpose basket as per site requirement including finishing (wherever required) and fittings. The same shall be fixed with necessary stainless steel nuts & bolts, Stainless Steel screws & telescopic channel etc. as per direction of Engineer-in-charge.(For payment purpose only weight of Stainless steel basket shall be considered excluding weight of all fixing accessories such as nuts, bolts, fasteners telescopic basket channels etc.Payment of providing and fixing telescopic channel shall be paid separately)
74SS Hanging Rod for CB
75Providing and fixing 25 mm dia. SS pipe Hanging rods with SS brackets :
76Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade : Two or more coats on new work
77Steel Work
78Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
79Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge.
80Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes.
81ALUMINIUM WORK
82System Aluminium Factory made Double Rebate Windows with Grill and Mesh Providing and fixing of A2Z Series Double rebate windows & ventilators made of High-performance factory-made system Aluminium windows with Akzonobel powder coating of 60-70 microns (Any RAL Colour). Section for Outer frame should be a single section of 91mm x 35mm, Glass shutter frame shall be of 54mm x 30mm, Mesh shutter frame shall be of 54mm x 30mm, 5mm thick Single Glazed beading shall be of 15mm x 18mm. 5mm thick Clear Tuffened Glass shall be used in all the windows & ventilators. Stainless Steel Wire Mesh shall be used in Wire mesh Shutters. No Coupling of 2 windows shall be allowed in any type of design. 10mm Sq bar M.S. Grill/Guard bar with 150mm c/c shall be fixed in between glass & mesh shutter. All frame corners shall be joined/assembled using self-locating corner cleats (No screwing at corners shall be allowed). All Hardware shall be used from a reputed brand, weather silicon shall be used for filling the gap between window opening & window Frame complete in all respect including all taxes.
83Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
84Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
85Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm
86Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
87Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
88Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well a curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
89Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent
90Providing and fixing machine cut, mirror/ eggshell polished , granite work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charg .Granite of all colour except black, cherry/ruby red 18 mm thick (slab area above 0.50 sqm)
91Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30mm thick (minimum) sheet, 1200 mm long spaced between main\\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
9212.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardantPVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back sidemetalized polyester film so as to make the tile a completely sealed unit.
93Finishing
94External Plaster in CM 1:4 with18mm thick in Two coats comprising of first layer 12mm thick cement plaster finished with a top layer 6mm thick cement plaster cement: 4 coarse sand)
95Rate for First layer 12mm thick cement plaster DSR item No. 13.4.1=Rs. 357.35
96Rate for top layer 6mm thick cement plaster cement DSR item No. 13.4.1=Rs. 357.35/2=153.63
97Total Rate For 18mm Thick Plaster=357.35+178.68=536.03
98Extra for providing and mixing water proofing material in cement of plaster work in proportion recommended by the manufacturers.
9912mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. 1:6 (1 cement: 6 coarse sand)
1006 mm cement plaster on celling (a) 1:3(1 cement:3 fine sand)
101Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats
102Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10sqm. Over and including priming coat of exterior primerapplied @ 0.90 litre/10 sqm.
103Steel Painting:Applying priming coat:
104With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood
105With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.
106Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.
107Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
108Water Proofing
109Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
110Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:
111(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.
112(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
113(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.
114(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.
115(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”:
116With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
117PLUMBING ESTIMATE ( STAFF QUARTERS (TYPE-II) (G+2) (13 Unit))
118SUB HEAD - I : SANITARY FIXTURES ( PROVIDING AND FIXING )
119Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
120White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
121Providing and Fixing White Viterous China Extended wall mounting water closet of size 780 x 370 x 690 mm of approved shape including providing and fixing white viterous china cistern with dual flush fittings of flushing capacity 3 litre / 6 litre ( adjustable to 4 litre / 8 litre ) including seat cover and cistern fittings nuts bolts and gaskets etc complete .
122Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat as lid,10 litre low level white P.V.C flushing cistern with manually controlled device (handle lever)conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.W.C. pan with ISI marked white solid plastic seat and lid
123Providing and fixing wash basin with C.I. brackets 15 mm dia CP brass single hole basin mixer of approved quality and make including painting of fittings and brackets cutting and making good the walls wherever required
124White Viterous china Wash basin size 550x400 mm with a 15 mm CP brass single hole basin mixer
125Providing and Fixing Stainless Steel A ISI 304 ( 18/8 ) kitchen sink as per IS : 13983 with CI Brackets and stainless steel plug 40 mm , including painting of fittings and brackets , cutting and making good the walls wherever required .
126Kitchen Sink with drain board
127510 x 1040 mm bowl depth 250 mm
128Providing and Fixing CP brass bib cock of approved quality conforming to IS : 8931
12915 mm nominal bore
130Providing and Fixing CP brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms .
13115 mm nominal bore
132Providing and Fixing CP brass angle valve for basin mixer and geyser points of approved quality conforming to IS : 8931
13315 mm nominal bore
134Providing and Fixing CP brass stop cock ( concealed ) of standard design and of approved make conforming to IS : 8931
13515 mm nominal bore
136Providing and placing on terrace ( at all floor levels ) polythylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet , outlet and overflow pipes but without fittings and the base support for tank .
137Providing & fixing of Waste pipe for Wash basins & Sinks including pvc waste fittings complete.
13832 mm dia
13940 mm dia
140Providing & fixing PTMT liquid soap container 109mm wide,125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour. weighing not less than 105 gms.
141Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour,weighing not less than 88 gms.
142Providing & fixing PTMT towel rail complete with brackets fixed to wooden cleats with C.P brass screws with concealed fitting arangement of approved quality and colour.
143600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gram.less
144Providing & fixing PTMT soap dish Holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting arrangements.Weighing not less than 106gms.
145Providing & fixing 600 x 450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with CP brass Screws and washers complete .
146Providing & fixing toilet paper holder:
147C.P.brass
148Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.
14915 mm nominal bore with 45cm length
150Providing and fixing CP brass shower rose with 15 or 20 mm inlet
151100 mm diameter
152Providing & Fixing CP brass single lever telephonic wall mixer of quality and make as approved by engineer - in - charge .
15315 mm nominal dia
154Providing and Fixing White Viterous China battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre and post flushing with water ( 250 ml and 500 ml consumption ) , having water inlet from back side , including fixing to wall with suitable brackets all as per manufacturer specification and direction of engineer - in - charge .
155Providing & fixing C.P. brass Central hole wall mounted sink Mixer with aerator connecting legs & 2 nos CP brass wall flange and 2 nos CP brass stop cock including cutting & making good the walls wherever required complete in all respect as per direction of engineer - in - charge .
156Providing and fixing C.P. brass Double coat hooks fixed in Toilet wall with C.P brass wall flanges & C.P. brass screws and other required accessories complete in all respect as per direction of engineer - in - charge .
157Providing and fixing health faucet with 1 m CP brass flexible tube and swivel hook with CP brass wall flange including cutting & making good the walls wherever required complete in all respect as per direction of engineer in charge .
158Providing and fixing vertical or horizontal storage type hot water heater electrical operated fixed to wall with anchor bolts & nuts, 15mm CP brass angle stop cock and 15mm CP brass non-return valve complete including making connections with 15mm dia CP connecting pipes on inlet and outlet, suitable length of power cable and 15 amps plug .
15915 Litre Capacity
16025 Litre Capacity
161SUB HEAD - II : INTERNAL DRAINAGE (RAINWATER, SOIL, WASTE & FITTINGS)
162Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 mx1 mx400 micron, finished 12 mm cement plaster 1:3 (1 cement:3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete
163Providing and Fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams .
164Providing and Fixing 100 mm diameter and 60 cm long rain water spout in cement mortar 1:4 ( 1 Cement : 4 Fine Sand )
165Stone ware Spout
166Providing and Fixing on wall face Unplasticised rigid pvc rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion .
167Single Socketed Pipes
16875 mm diameter
169110 mm diameter
170Providing and Fixing on wall face Rigid Unplasticised UPVC moulded fittings / accessories for unplasticised Rigid PVC Rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion .
171Coupler
17275 mm diameter
173110 mm diameter
174Single Push Fit Coupler
17575 mm diameter
176110 mm diameter
177Single Tee with door
17875x75x75 mm
179110x110x110 mm
180Single Tee without door
18175x75x75 mm
182110x110x110 mm
183Bend 87.5 degree
18475 mm bend
185110 mm bend
186Shoe ( Plain )
18775 mm Shoe
188110 mm Shoe
189Providing and Fixing unplasticised PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs , screwed with MS screws of required length , including cutting brick work with fixing in cement mortar 1:4 ( 1 Cement : 4 Coarse Sand ) and making good the wall etc . complete
19075 mm diameter
191110 mm diameter
192Providing and Fixing Soil , Waste and Vent Pipes :
193100 mm dia
194Centrifugally cast ( spun ) iron socket and spigot ( S & S ) pipe as per IS : 3989
19575 mm dia
196Centrifugally cast ( spun ) iron socket and spigot ( S & S ) pipe as per IS : 3989
197Providing and Filling the joints with spun yarn , cement slurry and cement mortar 1 : 2 ( 1 Cement : 2 fine Sand ) in SCI / CI Pipes :
19875 mm dia Pipe
199100 mm dia Pipe
200Providing and Fixing MS holder bat clamps of approved design to sand cast iron / cast iron ( spun ) pipe embedded in and including cement concrete blocks 10 x 10 x 10 cm of cement concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 graded stone aggregate 20 mm nominal sizes ) including cost of cutting holes and making good the walls etc .
201For 100 mm dia Pipe
202For 75 mm dia Pipe
203Providing and Fixing Bend of Required degree with access door , insertion rubber washers 3 mm thick , bolts and nuts complete .
204100 mm dia
205Sand Cast iron S & S as per IS : 3989
206Providing and Fixing Plain Bend of Required degree .
207100 mm dia
208Sand Cast iron S & S as per IS : 3989
209Providing and Fixing Heel Rest Sanitary Bend
210100 mm dia
211Spun Cast Iron as per IS : 3989
212Providing and Fixing Double Equal Junction of Required degree with access door , insertion rubber washer 3 mm thick , bolts and nuts complete .
213100x100x100x100 mm
214Spun Cast Iron as per IS : 3989
21575x75x75x75 mm
216Spun Cast Iron as per IS : 3989
217Providing and Fixing Single Equal Plain Junction of Required degree with access door , insertion rubber washer 3 mm thick , bolts and nuts complete .
218100x100x100 mm
219Sand Cast Iron S&S as per IS : 3989
22075x75x75 mm
221Sand Cast Iron S&S as per IS : 3989
222Providing and Fixing Single Unequal Junction of Required degree with access door , insertion rubber washer 3 mm thick , bolts and nuts complete .
223100 x 100 x 75 mm
224Sand Cast Iron S & S as per IS : 3989
225Providing and Fixing Single Unequal Plain Junction of Required degree .
226100 x 100 x 75 mm
227Sand Cast Iron S & S as per IS : 3989
228Providing and Fixing Sand Cast Iron S & S offsets as per IS : 3989
229150 mm off sets
230With 75 mm dia Pipe
231With 100 mm dia Pipe
232Providing and Fixing door piece , insertion rubber washer 3 mm thick , bolts and nuts complete .
233100 mm
234Spun Cast Iron as per IS : 3989
23575 mm
236Spun Cast Iron as per IS : 3989
237Providing and Fixing Terminal Guard :
238100 mm
239Sand Cast Iron S & S as per IS : 3989
24075 mm
241Sand Cast Iron S & S as per IS : 3989
242Providing and Fixing Collar :
243100 mm
244Sand Cast Iron S & S as per IS : 3989
24575 mm
246Sand Cast Iron S & S as per IS : 3989
247Providing Lead Caulked Joints to Sand Cast iron / centrifugally cast spun iron pipes and fittings of diameter :
248100 mm dia pipe
24975 mm dia pipe
250Providing and Fixing MS Stays and clamps for sand cast iron / centrifugally cast ( spun ) iron pipes of diameter :
251100 mm dia pipe
25275 mm dia pipe
253Providing and Fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete , including cost of cutting and making good the walls and floors .
254100 mm inlet and 100 mm outlet
255Sand Cast Iron S & S as per IS : 3989
256Painting Sand cast iron / centrifugally cast ( spun ) iron soil , waste , vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey , or buff etc . Over a coat of primer ( of approved quality ) for new work :
257100 mm diameter Pipes
25875 mm diameter Pipes
259Providing and Fixing GI Pipes complete with GI Fittings and clamps including cutting and making good the walls etc .
260Internal Work - Exposed on Wall
26132 mm dia nominal bore
26240 mm dia nominal bore
26350 mm dia nominal bore
264Painting GI Pipes and Fittings with Synthetic enamel white paint with two coats over a ready mixed priming coat , both of approved quality for new work :
26532 mm diameter pipe
26640 mm diameter pipe
26750 mm diameter pipe
268Providing and fixing multi-floor trap fitting with maximum 3 inlets 32,40 or 50 mm size fabricated from 100 dia GI pipes heavy duty and sockets,fixed to C.I. trap with Drip Seal joint and set in cement concrete as per standard drawing complete in all respect as directed by Engineer-in-charge.
269Providing & fixing 100mm x 50mm G.I. waste with reducing elbow & nipple cutting chases, the floor / slab, repairs complete as required and connection to GI / CI waste pipe complete in all respect as directed by Engineer-in-charge.
270Providing and fixing CP Brass floor cleanout plug / Clean out plug as per drawing complete with G.I. Socket jointed to drainage pipe outlet including drip seal joint complete in all respect as directed by Engineer-in-charge.
271100 mm diameter Pipe
272150 mm diameter Pipe
273Providing and fixing Stainless Steel Grade (304) grating with ring and Stainless steel anti cockroach basket and two SS screw including fixing to the floor with cement mortar.
274SUB HEAD - III : INTERNAL WATER SUPPLY
275Providing and fixing G.I. Pipes complete with G.I. fittings and clamps,including cutting and making good the walls etc
27615 mm dia pipes
27720 mm dia pipes
27825 mm dia pipes
27932 mm dia pipes
28040 mm dia pipes
28150 mm dia pipes
282Painting GI Pipes & Fittings with synthetic enamel white paint with two coats over a ready mixed priming coat , both of approved quality for new work .
28315 mm dia pipes
28420 mm dia pipes
28525 mm dia pipes
28632 mm dia pipes
28740 mm dia pipes
28850 mm dia pipes
289Providing and Fixing GI Union in GI Pipe including cutting and threading the pipe and making long screws etc . Complete ( New Work )
29015 mm dia pipes
29120 mm dia pipes
29225 mm dia pipes
29332 mm dia pipes
29440 mm dia pipes
29550 mm dia pipes
29665 mm dia pipes
29780 mm dia pipes
298Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and makin good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.)
29915 mm dia pipes
30020 mm dia pipes
30125 mm dia .Pipes.
30232 mm dia .Pipes.
303Providing and fixing Thermoflex or Careflex thermal insulation tubing, a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber over pipes of following nominal bores and thickness including all required accessories complete as per specification.
3049 mm thick ( Pipe Inside the Toilets and Exposed in Shafts and Terrace )
305For 15 mm dia Pipe
306For 20 mm dia Pipe
307For 25 mm dia Pipe
308For 32 mm dia Pipe
309For 40 mm dia Pipe
310For 50 mm dia Pipe
311Providing, fixing, testing and commissioning of motorised butterfly valve of following dia for filling of overhead water tank complete with high and low level control switches to control tanks. The level controllers shall be installed in overhead tanks. The level switch will close the valve when water level is high in overhead tank and open the valve when overhead water tank level is low. The system should be complete in all respects with accessories 220 V AC / 24 V DC, IP67 electrical water level control unit, copper control wiring in whether proof casing etc.
31240 mm dia Pipe
31350 mm dia Pipe
314Providing and Fixing full way lever operated forged brass ball valve of brass body with forged brass hard chromeplated steel ball tasted to a pressure not less than 15 kg/sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc.
31515 mm dia
31620 mm dia
31725 mm dia
31832 mm dia
31940 mm dia
32050 mm dia
321INTERNAL ELECTRICAL WORK (STAFF QUARTERS ) (TYPE-II) (G+2) (13 Unit)
322SUB HEAD - I: CIRCUIT CUM POINT WIRING
323SWITCH CONTROL LIGHT POINTS
324Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. .
325Group A
326Group B
327Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
328Group A
329Group B
330MCB CONTROL LIGHT POINTS
331Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Switch Control Primary Points)
332Primary point controlled by one MCB.
333Same as item above but Secondary point. i.e. Points to be looped with Primary point with 1.5 sqmm wire and Point wiring
334Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
3352 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
3362 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
3372 X 4 sq. mm + 1 X 4 sq. mm earth wire
3382 X 6 sq. mm + 1 X 6 sq. mm earth wire
3392 x 10 sq. mm + 1 x 6 sq.mm earth wire
3404 X 10 sq. mm + 2 X 6 sq. mm earth wire
3414 X 16 sq. mm + 2 X 6 sq. mm earth wire
342Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 Amp modular socket outlet and 5/6 A modular switch, connection etc. as required.
343Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 Amp modular socket outlet and 15/16 A modular switch, connection etc. as required.
344Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
345Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 Amps modular SP MCB, “C” curve including connection, painting etc. as required. (AC's & Gysers)
346Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
347Telephone socket outlet
348TV antenna socket outlet
349Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
3501 or 2 Module (75mmX75mm)
3516 module (78mm X 205 mm X 50 mm)
352Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
3533 pin , 5/6 amps socket outlet
3545/6 amps switch
355Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
35625 mm
35732 mm
358SUBHEAD -II - FITTINGS & FIXTURES
359Supply, Installation, Testing and Commissioning of 10 W Bulk head Light.
360Supply, Installation, Testing and Commissioning of 5W Mirror Light.
361Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim
3628-10 Watt
36312-15 Watt
36418 Watt
365Supplying, installation, Testing & Commissioning of LED (surface/wall) mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq. 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) Batten light (System lumen efficacy >135 lm/Watt)
36618-22 Watt
367Supply, Installation, Testing and Commissioning of 10W (Nominal) Wall Bracket Light
368Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (prefreably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req.
3691200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
370Supply, installation, Testing and commissioning of 250mm Exhaust fan.
371Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
372SUBHEAD - III - DISTRIBUTION BOARDS
373Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
3746 way, Double door
3758 way, Double door
37612 way, Double door
377Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator)
3786 way (4 + 18), Double door
3798 way (4 + 24), Double door
380Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
381Single Pole
382Single Pole Neutral
383Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
384Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
385Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
386Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
387SUB HEAD -IV - LT CABLES & CABLE TRAYS
388Laying of one number PVC Insulated and PVC shethed /XLPE power Cables of 1.1 KV grade of following size direct in ground including excavation,sand cushioning and protecting covering and refilling the trench etc as required.
389Up to 35 sq mm.
390Above 35 sq mm and up to 95 sq mm.
391Above 95 sq mm and up to 185 sq mm.
392Laying of one number PVC insulated & PVC sheathed/ XLPE Power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required.
393Upto 35 sq.mm
394Above 35 sq. mm and upto 95 sq. mm
395Above 95 sq.mm and upto 185 sq.mm
396S/ F powder coated of approved shade MS Cable Trays
397Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required..
398100 mm width X 50 mm depth X 1.6 mm thickness
399150 mm width X 50 mm depth X 1.6 mm thickness
400300 mm width X 50 mm depth X 1.6 mm thickness
401S/ F powder coated of approved shade MS Cable Tray Bends
402Supplying and installing following size of perforated powder coated of approved shade M.S. cable tray bends with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
403100 mm width X 50 mm depth X 1.6 mm thickness
404150 mm width X 50 mm depth X 1.6 mm thickness
405S/ F powder coated of approved shade MS Cable Tray Tee's
406Supplying and installing following size of perforated powder coated of approved shade M.S. cable tray tee's with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
407100 mm width X 50 mm depth X 1.6 mm thickness
408150 mm width X 50 mm depth X 1.6 mm thickness
409Supply of following sizes of XLPE insulated Aluminum conductor strip/ wire Armoured, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS-7098 Code and technical specifications.
4104 X 10 sq. mm (28mm)
4114 X 16 sq. mm (28mm)
4123½ X 35 sq. mm (32mm)
4133½ X 50 sq. mm (35mm)
4143½ X 95 sq. mm (38mm)
4153½ X 120 sq. mm (38mm)
416XLPE Insulated Copper Armoured Cables
4172C x 6 Sq.mm.
4182C x 4 Sq.mm.
4193C x 6 Sq.mm.
4203C x 4 Sq.mm.
4214CX 2.5 Sq.mm
4224C x 4 Sq.mm.
423Supply and making End termination with brass Single/ Double compression gland including providing and crimping of aluminum/copper solderless lugs/ferrules for XLPE/PVC insulated armoured power aluminum/copper conductor cables 1.1 KV grade of following sizes:
424SINGLE COMPRESSION GLAND FOR AI. AR. CABLE
4254C/3C x 6/4 sq.mm.
426Single Compression Gland for Cu. Cable
4274C/3C/2C x 4/6/2.5 sq.mm.
428Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV gradeas required.
4294 X 10 sq. mm (25mm)
4304 X 16 sq. mm (28mm)
4313½ X 25 sq. mm (28mm)
4323½ X 35 sq. mm (32mm)
4333½ X 50 sq. mm (35mm)
4343½ X 95 sq. mm (45mm)
4353½ X 120 sq. mm (45mm)
436SUB HEAD -V - EARTHING SYSTEM
437Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
438Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required.
439Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
440Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
441SUB HEAD - VI :LIGHTNING CONDUCTOR
442Earthing with Cu. earth Plate 600mm x 600mm x 3mm thick including accesssories, and providing masonary enclosure with cover plate (CI heavy duty) having locking arrangement and watering pipe of 2.7 mtr long etc. with charcoal or coke and salt ) as required.
443Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
444Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
445Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
446Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
447Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
448Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
449Supply of Lightnig counter - LCD screen shows the number of lightning strikes, hour and date of lightning events Buttons enable TIME/DATE setting and log viewing. Replaceable battery, working life minimum five years, meet the requirements for IS/IEC 62305 and IEC 62561-2.Tested for Electrical ,Mechanical and Chemical as per IEC 62561.
450TYPE-III RESIDENCES (G) 1 UNIT
451Earth Work
452Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge..All kinds of soil.
453Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
454Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete.
455Concrete Work
456Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 coarse sand (zone-iii) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
457Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
458Providing & applying a coat of residual petroleum bitumen of grade of Vg-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
459Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zoneiii) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
460Brick edging in full brick width and half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
461Brick Drain along Plinth Protection (Size 250X300 MM )
462Reinforced Cement Concrete
463Centering and shuttering including strutting, propping etc. and removal of form for
464Foundations, footings, bases of columns, etc. for mass concrete.
465Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick
466Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick
467Columns,Pillars, Piers, Abutments, Posts and Struts.
468Edges of slabs and breaks in floors and walls Under 20 cm wide.
469Steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-mechanically treated bars of grade fe-500D or more.
470Steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-mechanically treated bars of grade fe-500D or more.
471Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
472Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland Slag cement, admixtures in recommended proportions as per iS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and Reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
473All works upto plinth level
474Concrete of M25 grade with minimum cementcontent of 330 kg /cum
475(i) R.C.C. work in Footing
476(ii) R.C.C. work in Beam
477(iii) R.C.C. work in Columns
478All works above plinth level upto floor V level
479Concrete of M25 grade with minimum cementcontent of 330 kg /cum
480(i) R.C.C. work in Lintel
481(ii) R.C.C. work in Beam
482(iii) R.C.C. work in Columns
483(iv) R.C.C. work in Slab
484Add for using extra cement in the items of design mix over and above the specified cement content therein.
485Masonry Work
486Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. : cement mortar 1:4 (1 cement : 4 coarse sand)
487Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
488Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
489Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
490Cladding Work
491Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
492Granite stone slab colour black, Cherry/Ruby red
493Area of slab upto 0.50 sqm
494Area of slab over 0.50 sqm
495Providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
496Granite work
497Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete.
498Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
499Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. MINMUM SIZE OF TILE 300 MM X450 MM
500Wood and PVC Work
501Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) nondecorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
502Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
503Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.
504Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete.
505300 mm weighing not less than 200 gms
506250 mm weighing not less than 150 gms
507Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick
508Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
509Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 125 mm
510Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm .
511Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete.
512200 x 10mm
513150 x 10mm
514Steel Work
515Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
516Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
517Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
518Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes.
519Flooring
520Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
521Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
522Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/ Antiskid finish of Size of Tile 600 x 600 mm
523Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.size of tile 600x600 mm
524Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.size of tile 600x600 mm
525Finishing
52615 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand)
52712 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
5286 mm cement plaster on celling (a) 1:3(1 cement:3 fine sand)
529Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
530Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
531Applying priming coat:
532With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood
533With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.
534Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.
535Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
536Water Proofing
537Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:
538(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.
539(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
540(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.
541(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.
542(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”:
543With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
544PLUMBING ESTIMATE (TYPE-III RESIDENCES (G) 1 UNIT )
545SUB HEAD - I : SANITARY FIXTURES ( PROVIDING AND FIXING )
546Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
547White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
548Providing and Fixing White Viterous China Extended wall mounting water closet of size 780 x 370 x 690 mm of approved shape including providing and fixing white viterous china cistern with dual flush fittings of flushing capacity 3 litre / 6 litre ( adjustable to 4 litre / 8 litre ) including seat cover and cistern fittings nuts bolts and gaskets etc complete .
549Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat as lid,10 litre low level white P.V.C flushing cistern with manually controlled device (handle lever)conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.W.C. pan with ISI marked white solid plastic seat and lid
550Providing and fixing wash basin with C.I. brackets 15 mm dia CP brass single hole basin mixer of approved quality and make including painting of fittings and brackets cutting and making good the walls wherever required
551White Viterous china Wash basin size 550x400 mm with a 15 mm CP brass single hole basin mixer
552Providing and Fixing Stainless Steel A ISI 304 ( 18/8 ) kitchen sink as per IS : 13983 with CI Brackets and stainless steel plug 40 mm , including painting of fittings and brackets , cutting and making good the walls wherever required .
553Kitchen Sink with drain board
554510 x 1040 mm bowl depth 250 mm
555Providing and Fixing CP brass bib cock of approved quality conforming to IS : 8931
55615 mm nominal bore
557Providing and Fixing CP brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms .
55815 mm nominal bore
559Providing and Fixing CP brass angle valve for basin mixer and geyser points of approved quality conforming to IS : 8931
56015 mm nominal bore
561Providing and Fixing CP brass stop cock ( concealed ) of standard design and of approved make conforming to IS : 8931
56215 mm nominal bore
563Providing and placing on terrace ( at all floor levels ) polythylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet , outlet and overflow pipes but without fittings and the base support for tank .
564Providing & fixing of Waste pipe for Wash basins & Sinks including pvc waste fittings complete.
56532 mm dia
56640 mm dia
567Providing & fixing PTMT liquid soap container 109mm wide,125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour. weighing not less than 105 gms.
568Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour,weighing not less than 88 gms.
569Providing & fixing PTMT towel rail complete with brackets fixed to wooden cleats with C.P brass screws with concealed fitting arangement of approved quality and colour.
570600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gram.less
571Providing & fixing PTMT soap dish Holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting arrangements.Weighing not less than 106gms.
572Providing & fixing 600 x 450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with CP brass Screws and washers complete .
573Providing & fixing toilet paper holder:
574C.P.brass
575Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.
57615 mm nominal bore with 45cm length
577Providing and fixing CP brass shower rose with 15 or 20 mm inlet
578100 mm diameter
579Providing & Fixing CP brass single lever telephonic wall mixer of quality and make as approved by engineer - in - charge .
58015 mm nominal dia
581Providing and Fixing White Viterous China battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre and post flushing with water ( 250 ml and 500 ml consumption ) , having water inlet from back side , including fixing to wall with suitable brackets all as per manufacturer specification and direction of engineer - in - charge .
582Providing & fixing C.P. brass Central hole wall mounted sink Mixer with aerator connecting legs & 2 nos CP brass wall flange and 2 nos CP brass stop cock including cutting & making good the walls wherever required complete in all respect as per direction of engineer - in - charge .
583Providing and fixing C.P. brass Double coat hooks fixed in Toilet wall with C.P brass wall flanges & C.P. brass screws and other required accessories complete in all respect as per direction of engineer - in - charge .
584Providing and fixing health faucet with 1 m CP brass flexible tube and swivel hook with CP brass wall flange including cutting & making good the walls wherever required complete in all respect as per direction of engineer in charge .
585Providing and fixing vertical or horizontal storage type hot water heater electrical operated fixed to wall with anchor bolts & nuts, 15mm CP brass angle stop cock and 15mm CP brass non-return valve complete including making connections with 15mm dia CP connecting pipes on inlet and outlet, suitable length of power cable and 15 amps plug .
58615 Litre Capacity
58725 Litre Capacity
588SUB HEAD - II : INTERNAL DRAINAGE (RAINWATER, SOIL, WASTE & FITTINGS)
589Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 mx1 mx400 micron, finished 12 mm cement plaster 1:3 (1 cement:3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete
590Providing and Fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams .
591Providing and Fixing 100 mm diameter and 60 cm long rain water spout in cement mortar 1:4 ( 1 Cement : 4 Fine Sand )
592Stone ware Spout
593Providing and Fixing on wall face Unplasticised rigid pvc rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion .
594Single Socketed Pipes
59575 mm diameter
596110 mm diameter
597Providing and Fixing on wall face Rigid Unplasticised UPVC moulded fittings / accessories for unplasticised Rigid PVC Rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion .
598Coupler
59975 mm diameter
600110 mm diameter
601Single Push Fit Coupler
60275 mm diameter
603110 mm diameter
604Single Tee with door
60575x75x75 mm
606110x110x110 mm
607Single Tee without door
60875x75x75 mm
609110x110x110 mm
610Bend 87.5 degree
61175 mm bend
612110 mm bend
613Shoe ( Plain )
61475 mm Shoe
615110 mm Shoe
616Providing and Fixing unplasticised PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs , screwed with MS screws of required length , including cutting brick work with fixing in cement mortar 1:4 ( 1 Cement : 4 Coarse Sand ) and making good the wall etc . complete
61775 mm diameter
618110 mm diameter
619Providing and Fixing Soil , Waste and Vent Pipes :
620100 mm dia
621Centrifugally cast ( spun ) iron socket and spigot ( S & S ) pipe as per IS : 3989
62275 mm dia
623Centrifugally cast ( spun ) iron socket and spigot ( S & S ) pipe as per IS : 3989
624Providing and Filling the joints with spun yarn , cement slurry and cement mortar 1 : 2 ( 1 Cement : 2 fine Sand ) in SCI / CI Pipes :
62575 mm dia Pipe
626100 mm dia Pipe
627Providing and Fixing MS holder bat clamps of approved design to sand cast iron / cast iron ( spun ) pipe embedded in and including cement concrete blocks 10 x 10 x 10 cm of cement concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 graded stone aggregate 20 mm nominal sizes ) including cost of cutting holes and making good the walls etc .
628For 100 mm dia Pipe
629For 75 mm dia Pipe
630Providing and Fixing Bend of Required degree with access door , insertion rubber washers 3 mm thick , bolts and nuts complete .
631100 mm dia
632Sand Cast iron S & S as per IS : 3989
633Providing and Fixing Plain Bend of Required degree .
634100 mm dia
635Sand Cast iron S & S as per IS : 3989
636Providing and Fixing Heel Rest Sanitary Bend
637100 mm dia
638Spun Cast Iron as per IS : 3989
639Providing and Fixing Double Equal Junction of Required degree with access door , insertion rubber washer 3 mm thick , bolts and nuts complete .
640100x100x100x100 mm
641Spun Cast Iron as per IS : 3989
64275x75x75x75 mm
643Spun Cast Iron as per IS : 3989
644Providing and Fixing Single Equal Plain Junction of Required degree with access door , insertion rubber washer 3 mm thick , bolts and nuts complete .
645100x100x100 mm
646Sand Cast Iron S&S as per IS : 3989
64775x75x75 mm
648Sand Cast Iron S&S as per IS : 3989
649Providing and Fixing Single Unequal Junction of Required degree with access door , insertion rubber washer 3 mm thick , bolts and nuts complete .
650100 x 100 x 75 mm
651Sand Cast Iron S & S as per IS : 3989
652Providing and Fixing Single Unequal Plain Junction of Required degree .
653100 x 100 x 75 mm
654Sand Cast Iron S & S as per IS : 3989
655Providing and Fixing Sand Cast Iron S & S offsets as per IS : 3989
656150 mm off sets
657With 75 mm dia Pipe
658With 100 mm dia Pipe
659Providing and Fixing door piece , insertion rubber washer 3 mm thick , bolts and nuts complete .
660100 mm
661Spun Cast Iron as per IS : 3989
66275 mm
663Spun Cast Iron as per IS : 3989
664Providing and Fixing Terminal Guard :
665100 mm
666Sand Cast Iron S & S as per IS : 3989
66775 mm
668Sand Cast Iron S & S as per IS : 3989
669Providing and Fixing Collar :
670100 mm
671Sand Cast Iron S & S as per IS : 3989
67275 mm
673Sand Cast Iron S & S as per IS : 3989
674Providing Lead Caulked Joints to Sand Cast iron / centrifugally cast spun iron pipes and fittings of diameter :
675100 mm dia pipe
67675 mm dia pipe
677Providing and Fixing MS Stays and clamps for sand cast iron / centrifugally cast ( spun ) iron pipes of diameter :
678100 mm dia pipe
67975 mm dia pipe
680Providing and Fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete , including cost of cutting and making good the walls and floors .
681100 mm inlet and 100 mm outlet
682Sand Cast Iron S & S as per IS : 3989
683Painting Sand cast iron / centrifugally cast ( spun ) iron soil , waste , vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey , or buff etc . Over a coat of primer ( of approved quality ) for new work :
684100 mm diameter Pipes
68575 mm diameter Pipes
686Providing and Fixing GI Pipes complete with GI Fittings and clamps including cutting and making good the walls etc .
687Internal Work - Exposed on Wall
68832 mm dia nominal bore
68940 mm dia nominal bore
69050 mm dia nominal bore
691Painting GI Pipes and Fittings with Synthetic enamel white paint with two coats over a ready mixed priming coat , both of approved quality for new work :
69232 mm diameter pipe
69340 mm diameter pipe
69450 mm diameter pipe
695Providing and fixing multi-floor trap fitting with maximum 3 inlets 32,40 or 50 mm size fabricated from 100 dia GI pipes heavy duty and sockets,fixed to C.I. trap with Drip Seal joint and set in cement concrete as per standard drawing complete in all respect as directed by Engineer-in-charge.
696Providing & fixing 100mm x 50mm G.I. waste with reducing elbow & nipple cutting chases, the floor / slab, repairs complete as required and connection to GI / CI waste pipe complete in all respect as directed by Engineer-in-charge.
697Providing and fixing CP Brass floor cleanout plug / Clean out plug as per drawing complete with G.I. Socket jointed to drainage pipe outlet including drip seal joint complete in all respect as directed by Engineer-in-charge.
698100 mm diameter Pipe
699150 mm diameter Pipe
700Providing and fixing Stainless Steel Grade (304) grating with ring and Stainless steel anti cockroach basket and two SS screw including fixing to the floor with cement mortar.
701SUB HEAD - III : INTERNAL WATER SUPPLY
702Providing and fixing G.I. Pipes complete with G.I. fittings and clamps,including cutting and making good the walls etc
70315 mm dia pipes
70420 mm dia pipes
70525 mm dia pipes
70632 mm dia pipes
70740 mm dia pipes
70850 mm dia pipes
709Painting GI Pipes & Fittings with synthetic enamel white paint with two coats over a ready mixed priming coat , both of approved quality for new work .
71015 mm dia pipes
71120 mm dia pipes
71225 mm dia pipes
71332 mm dia pipes
71440 mm dia pipes
71550 mm dia pipes
716Providing and Fixing GI Union in GI Pipe including cutting and threading the pipe and making long screws etc . Complete ( New Work )
71715 mm dia pipes
71820 mm dia pipes
71925 mm dia pipes
72032 mm dia pipes
72140 mm dia pipes
72250 mm dia pipes
72365 mm dia pipes
72480 mm dia pipes
725Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and makin good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.)
72615 mm dia pipes
72720 mm dia pipes
72825 mm dia .Pipes.
72932 mm dia .Pipes.
730Providing and fixing Thermoflex or Careflex thermal insulation tubing, a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber over pipes of following nominal bores and thickness including all required accessories complete as per specification.
7319 mm thick ( Pipe Inside the Toilets and Exposed in Shafts and Terrace )
732For 15 mm dia Pipe
733For 20 mm dia Pipe
734For 25 mm dia Pipe
735For 32 mm dia Pipe
736For 40 mm dia Pipe
737For 50 mm dia Pipe
738Providing, fixing, testing and commissioning of motorised butterfly valve of following dia for filling of overhead water tank complete with high and low level control switches to control tanks. The level controllers shall be installed in overhead tanks. The level switch will close the valve when water level is high in overhead tank and open the valve when overhead water tank level is low. The system should be complete in all respects with accessories 220 V AC / 24 V DC, IP67 electrical water level control unit, copper control wiring in whether proof casing etc.
73940 mm dia Pipe
74050 mm dia Pipe
741Providing and Fixing full way lever operated forged brass ball valve of brass body with forged brass hard chromeplated steel ball tasted to a pressure not less than 15 kg/sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc.
74215 mm dia
74320 mm dia
74425 mm dia
74532 mm dia
74640 mm dia
74750 mm dia
748INTERNAL ELECTRICAL WORK (TYPE-III RESIDENCES (G) 1 UNIT)
749SUB HEAD - I: CIRCUIT CUM POINT WIRING
750SWITCH CONTROL LIGHT POINTS
751Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. .
752Group A
753Group B
754Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
755Group A
756Group B
757MCB CONTROL LIGHT POINTS
758Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Switch Control Primary Points)
759Primary point controlled by one MCB.
760Same as item above but Secondary point. i.e. Points to be looped with Primary point with 1.5 sqmm wire and Point wiring
761Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
7622 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
7632 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
7642 X 4 sq. mm + 1 X 4 sq. mm earth wire
7652 X 6 sq. mm + 1 X 6 sq. mm earth wire
7662 x 10 sq. mm + 1 x 6 sq.mm earth wire
7674 X 10 sq. mm + 2 X 6 sq. mm earth wire
7684 X 16 sq. mm + 2 X 6 sq. mm earth wire
769Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 Amp modular socket outlet and 5/6 A modular switch, connection etc. as required.
770Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 Amp modular socket outlet and 15/16 A modular switch, connection etc. as required.
771Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
772Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 Amps modular SP MCB, “C” curve including connection, painting etc. as required. (AC's & Gysers)
773Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
774Telephone socket outlet
775TV antenna socket outlet
776Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
7771 or 2 Module (75mmX75mm)
7786 module (78mm X 205 mm X 50 mm)
779Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
7803 pin , 5/6 amps socket outlet
7815/6 amps switch
782Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
78325 mm
78432 mm
785SUBHEAD -II - FITTINGS & FIXTURES
786Supply, Installation, Testing and Commissioning of 10 W Bulk head Light.
787Supply, Installation, Testing and Commissioning of 5W Mirror Light.
788Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim
7898-10 Watt
79012-15 Watt
79118 Watt
792Supplying, installation, Testing & Commissioning of LED (surface/wall) mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq. 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) Batten light (System lumen efficacy >135 lm/Watt)
79318-22 Watt
794Supply, Installation, Testing and Commissioning of 10W (Nominal) Wall Bracket Light
795Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (prefreably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req.
7961200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
797Supply, installation, Testing and commissioning of 250mm Exhaust fan.
798Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
799SUBHEAD - III - DISTRIBUTION BOARDS
800Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8016 way, Double door
8028 way, Double door
80312 way, Double door
804Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator)
8056 way (4 + 18), Double door
8068 way (4 + 24), Double door
807Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
808Single Pole
809Single Pole Neutral
810Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
811Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
812Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
813Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
814SUB HEAD -IV - LT CABLES & CABLE TRAYS
815Laying of one number PVC Insulated and PVC shethed /XLPE power Cables of 1.1 KV grade of following size direct in ground including excavation,sand cushioning and protecting covering and refilling the trench etc as required.
816Up to 35 sq mm.
817Above 35 sq mm and up to 95 sq mm.
818Above 95 sq mm and up to 185 sq mm.
819Laying of one number PVC insulated & PVC sheathed/ XLPE Power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required.
820Upto 35 sq.mm
821Above 35 sq. mm and upto 95 sq. mm
822Above 95 sq.mm and upto 185 sq.mm
823S/ F powder coated of approved shade MS Cable Trays
824Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required..
825100 mm width X 50 mm depth X 1.6 mm thickness
826150 mm width X 50 mm depth X 1.6 mm thickness
827300 mm width X 50 mm depth X 1.6 mm thickness
828S/ F powder coated of approved shade MS Cable Tray Bends
829Supplying and installing following size of perforated powder coated of approved shade M.S. cable tray bends with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
830100 mm width X 50 mm depth X 1.6 mm thickness
831150 mm width X 50 mm depth X 1.6 mm thickness
832S/ F powder coated of approved shade MS Cable Tray Tee's
833Supplying and installing following size of perforated powder coated of approved shade M.S. cable tray tee's with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
834100 mm width X 50 mm depth X 1.6 mm thickness
835150 mm width X 50 mm depth X 1.6 mm thickness
836Supply of following sizes of XLPE insulated Aluminum conductor strip/ wire Armoured, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS-7098 Code and technical specifications.
8374 X 10 sq. mm (28mm)
8384 X 16 sq. mm (28mm)
8393½ X 35 sq. mm (32mm)
8403½ X 50 sq. mm (35mm)
8413½ X 95 sq. mm (38mm)
8423½ X 120 sq. mm (38mm)
843XLPE Insulated Copper Armoured Cables
8442C x 6 Sq.mm.
8452C x 4 Sq.mm.
8463C x 6 Sq.mm.
8473C x 4 Sq.mm.
8484CX 2.5 Sq.mm
8494C x 4 Sq.mm.
850Supply and making End termination with brass Single/ Double compression gland including providing and crimping of aluminum/copper solderless lugs/ferrules for XLPE/PVC insulated armoured power aluminum/copper conductor cables 1.1 KV grade of following sizes:
851SINGLE COMPRESSION GLAND FOR AI. AR. CABLE
8524C/3C x 6/4 sq.mm.
853Single Compression Gland for Cu. Cable
8544C/3C/2C x 4/6/2.5 sq.mm.
855Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV gradeas required.
8564 X 10 sq. mm (25mm)
8574 X 16 sq. mm (28mm)
8583½ X 25 sq. mm (28mm)
8593½ X 35 sq. mm (32mm)
8603½ X 50 sq. mm (35mm)
8613½ X 95 sq. mm (45mm)
8623½ X 120 sq. mm (45mm)
863SUB HEAD -V - EARTHING SYSTEM
864Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
865Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required.
866Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
867Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
868SUB HEAD - VI :LIGHTNING CONDUCTOR
869Earthing with Cu. earth Plate 600mm x 600mm x 3mm thick including accesssories, and providing masonary enclosure with cover plate (CI heavy duty) having locking arrangement and watering pipe of 2.7 mtr long etc. with charcoal or coke and salt ) as required.
870Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
871Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
872Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
873Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
874Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
875Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
876Supply of Lightnig counter - LCD screen shows the number of lightning strikes, hour and date of lightning events Buttons enable TIME/DATE setting and log viewing. Replaceable battery, working life minimum five years, meet the requirements for IS/IEC 62305 and IEC 62561-2.Tested for Electrical ,Mechanical and Chemical as per IEC 62561.
877PRINCIPAL RESIDENCE
878Earth Work
879Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
880Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
881Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete.
882Concrete Work
883Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 coarse sand (zone-iii) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
884Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
885Providing & applying a coat of residual petroleum bitumen of grade of Vg-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
886Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zoneiii) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
887Brick edging in full brick width and half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
888Brick Drain along Plinth Protection (Size 250X300 MM )
889Reinforced Cement Concrete
890Centering and shuttering including strutting, propping etc. and removal of form for
891Foundations, footings, bases of columns, etc. for mass concrete.
892Suspended floors, roofs, landings, balconies and access platform
893Lintels, beams, plinth beams, girders, bressumers and cantilevers
894Columns,Pillars, Piers, Abutments, Posts and Struts.
895Edges of slabs and breaks in floors and walls Under 20 cm wide.
896Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
897Steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-mechanically treated bars of grade fe-500D or more.
898Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
899Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland Slag cement, admixtures in recommended proportions as per iS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and Reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
900All works upto plinth level
901Concrete of M25 grade with minimum cementcontent of 330 kg /cum
902(i) R.C.C. work in Footing
903(ii) R.C.C. work in Beam
904(iii) R.C.C. work in Columns
905All works above plinth level upto floor V level
906Concrete of M25 grade with minimum cementcontent of 330 kg /cum
907(i) R.C.C. work in Lintel
908(ii) R.C.C. work in Beam
909(iii) R.C.C. work in Columns
910(iv) R.C.C. work in Slab
911Masonry Work
912Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
913Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)
914Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.ird course of half brick masonry.
915Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
916Cladding Work
917Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
918Granite stone slab colour black, Cherry/Ruby red
919Area of slab upto 0.50 sqm
920Area of slab over 0.50 sqm
921Providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
922Granite work
923Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete.
924Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
925Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. MINMUM SIZE OF TILE 300 MM X450 MM
926Wood and PVC Work
927Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) nondecorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
928Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
929Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.
930Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick
931Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
932Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 125 mm
933Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm .
934Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete.
935200 x 10mm
936150 x 10mm
937Steel Work
938Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
939Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes
940Supply & fixing of Aluminium 3 Track Sliding windows with Grill as per design & specifications with outer frame 86.5mm X 48mm, Shutter section 65mm X 29mm, Mesh Shutter 66.7mm X 29mm, Powder coated (any RAL Colour), 6mm Clear tuffened glass, Wire Mesh, Handle, EPDM Gasket, Silicon sealant, 10mm Sq bar M.S. Grill/Guard bar with 150mm c/c shall be integrated in the windows with complete hardware of reputed brand,
941Flooring
942Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
943Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
944Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of requiredthickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm
945Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.size of tile 600x600 mm
946Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.size of tile 600x600 mm
947Finishing
94815 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand)
94912 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
9506 mm cement plaster on celling (a) 1:3(1 cement:3 fine sand)
951Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
952Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
953Applying priming coat:
954With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood
955With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.
956Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.
957Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
958Water Proofing
959Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:
960(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.
961(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
962(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.
963(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.
964(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”:
965With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
966PLUMBING ESTIMATE (PRINCIPAL RESIDENCE )
967SUB HEAD - I : SANITARY FIXTURES ( PROVIDING AND FIXING )
968Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
969White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
970Providing and Fixing White Viterous China Extended wall mounting water closet of size 780 x 370 x 690 mm of approved shape including providing and fixing white viterous china cistern with dual flush fittings of flushing capacity 3 litre / 6 litre ( adjustable to 4 litre / 8 litre ) including seat cover and cistern fittings nuts bolts and gaskets etc complete .
971Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat as lid,10 litre low level white P.V.C flushing cistern with manually controlled device (handle lever)conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.W.C. pan with ISI marked white solid plastic seat and lid
972Providing and fixing wash basin with C.I. brackets 15 mm dia CP brass single hole basin mixer of approved quality and make including painting of fittings and brackets cutting and making good the walls wherever required
973White Viterous china Wash basin size 550x400 mm with a 15 mm CP brass single hole basin mixer
974Providing and Fixing Stainless Steel A ISI 304 ( 18/8 ) kitchen sink as per IS : 13983 with CI Brackets and stainless steel plug 40 mm , including painting of fittings and brackets , cutting and making good the walls wherever required .
975Kitchen Sink with drain board
976510 x 1040 mm bowl depth 250 mm
977Providing and Fixing CP brass bib cock of approved quality conforming to IS : 8931
97815 mm nominal bore
979Providing and Fixing CP brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms .
98015 mm nominal bore
981Providing and Fixing CP brass angle valve for basin mixer and geyser points of approved quality conforming to IS : 8931
98215 mm nominal bore
983Providing and Fixing CP brass stop cock ( concealed ) of standard design and of approved make conforming to IS : 8931
98415 mm nominal bore
985Providing and placing on terrace ( at all floor levels ) polythylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet , outlet and overflow pipes but without fittings and the base support for tank .
986Providing & fixing of Waste pipe for Wash basins & Sinks including pvc waste fittings complete.
98732 mm dia
98840 mm dia
989Providing & fixing PTMT liquid soap container 109mm wide,125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour. weighing not less than 105 gms.
990Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour,weighing not less than 88 gms.
991Providing & fixing PTMT towel rail complete with brackets fixed to wooden cleats with C.P brass screws with concealed fitting arangement of approved quality and colour.
992600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gram.less
993Providing & fixing PTMT soap dish Holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting arrangements.Weighing not less than 106gms.
994Providing & fixing 600 x 450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with CP brass Screws and washers complete .
995Providing & fixing toilet paper holder:
996C.P.brass
997Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.
99815 mm nominal bore with 45cm length
999Providing and fixing CP brass shower rose with 15 or 20 mm inlet
1000100 mm diameter
1001Providing & Fixing CP brass single lever telephonic wall mixer of quality and make as approved by engineer - in - charge .
100215 mm nominal dia
1003Providing and Fixing White Viterous China battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre and post flushing with water ( 250 ml and 500 ml consumption ) , having water inlet from back side , including fixing to wall with suitable brackets all as per manufacturer specification and direction of engineer - in - charge .
1004Providing & fixing C.P. brass Central hole wall mounted sink Mixer with aerator connecting legs & 2 nos CP brass wall flange and 2 nos CP brass stop cock including cutting & making good the walls wherever required complete in all respect as per direction of engineer - in - charge .
1005Providing and fixing C.P. brass Double coat hooks fixed in Toilet wall with C.P brass wall flanges & C.P. brass screws and other required accessories complete in all respect as per direction of engineer - in - charge .
1006Providing and fixing health faucet with 1 m CP brass flexible tube and swivel hook with CP brass wall flange including cutting & making good the walls wherever required complete in all respect as per direction of engineer in charge .
1007Providing and fixing vertical or horizontal storage type hot water heater electrical operated fixed to wall with anchor bolts & nuts, 15mm CP brass angle stop cock and 15mm CP brass non-return valve complete including making connections with 15mm dia CP connecting pipes on inlet and outlet, suitable length of power cable and 15 amps plug .
100815 Litre Capacity
100925 Litre Capacity
1010SUB HEAD - II : INTERNAL DRAINAGE (RAINWATER, SOIL, WASTE & FITTINGS)
1011Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 mx1 mx400 micron, finished 12 mm cement plaster 1:3 (1 cement:3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete
1012Providing and Fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams .
1013Providing and Fixing 100 mm diameter and 60 cm long rain water spout in cement mortar 1:4 ( 1 Cement : 4 Fine Sand )
1014Stone ware Spout
1015Providing and Fixing on wall face Unplasticised rigid pvc rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion .
1016Single Socketed Pipes
101775 mm diameter
1018110 mm diameter
1019Providing and Fixing on wall face Rigid Unplasticised UPVC moulded fittings / accessories for unplasticised Rigid PVC Rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion .
1020Coupler
102175 mm diameter
1022110 mm diameter
1023Single Push Fit Coupler
102475 mm diameter
1025110 mm diameter
1026Single Tee with door
102775x75x75 mm
1028110x110x110 mm
1029Single Tee without door
103075x75x75 mm
1031110x110x110 mm
1032Bend 87.5 degree
103375 mm bend
1034110 mm bend
1035Shoe ( Plain )
103675 mm Shoe
1037110 mm Shoe
1038Providing and Fixing unplasticised PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs , screwed with MS screws of required length , including cutting brick work with fixing in cement mortar 1:4 ( 1 Cement : 4 Coarse Sand ) and making good the wall etc . complete
103975 mm diameter
1040110 mm diameter
1041Providing and Fixing Soil , Waste and Vent Pipes :
1042100 mm dia
1043Centrifugally cast ( spun ) iron socket and spigot ( S & S ) pipe as per IS : 3989
104475 mm dia
1045Centrifugally cast ( spun ) iron socket and spigot ( S & S ) pipe as per IS : 3989
1046Providing and Filling the joints with spun yarn , cement slurry and cement mortar 1 : 2 ( 1 Cement : 2 fine Sand ) in SCI / CI Pipes :
104775 mm dia Pipe
1048100 mm dia Pipe
1049Providing and Fixing MS holder bat clamps of approved design to sand cast iron / cast iron ( spun ) pipe embedded in and including cement concrete blocks 10 x 10 x 10 cm of cement concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 graded stone aggregate 20 mm nominal sizes ) including cost of cutting holes and making good the walls etc .
1050For 100 mm dia Pipe
1051For 75 mm dia Pipe
1052Providing and Fixing Bend of Required degree with access door , insertion rubber washers 3 mm thick , bolts and nuts complete .
1053100 mm dia
1054Sand Cast iron S & S as per IS : 3989
1055Providing and Fixing Plain Bend of Required degree .
1056100 mm dia
1057Sand Cast iron S & S as per IS : 3989
1058Providing and Fixing Heel Rest Sanitary Bend
1059100 mm dia
1060Spun Cast Iron as per IS : 3989
1061Providing and Fixing Double Equal Junction of Required degree with access door , insertion rubber washer 3 mm thick , bolts and nuts complete .
1062100x100x100x100 mm
1063Spun Cast Iron as per IS : 3989
106475x75x75x75 mm
1065Spun Cast Iron as per IS : 3989
1066Providing and Fixing Single Equal Plain Junction of Required degree with access door , insertion rubber washer 3 mm thick , bolts and nuts complete .
1067100x100x100 mm
1068Sand Cast Iron S&S as per IS : 3989
106975x75x75 mm
1070Sand Cast Iron S&S as per IS : 3989
1071Providing and Fixing Single Unequal Junction of Required degree with access door , insertion rubber washer 3 mm thick , bolts and nuts complete .
1072100 x 100 x 75 mm
1073Sand Cast Iron S & S as per IS : 3989
1074Providing and Fixing Single Unequal Plain Junction of Required degree .
1075100 x 100 x 75 mm
1076Sand Cast Iron S & S as per IS : 3989
1077Providing and Fixing Sand Cast Iron S & S offsets as per IS : 3989
1078150 mm off sets
1079With 75 mm dia Pipe
1080With 100 mm dia Pipe
1081Providing and Fixing door piece , insertion rubber washer 3 mm thick , bolts and nuts complete .
1082100 mm
1083Spun Cast Iron as per IS : 3989
108475 mm
1085Spun Cast Iron as per IS : 3989
1086Providing and Fixing Terminal Guard :
1087100 mm
1088Sand Cast Iron S & S as per IS : 3989
108975 mm
1090Sand Cast Iron S & S as per IS : 3989
1091Providing and Fixing Collar :
1092100 mm
1093Sand Cast Iron S & S as per IS : 3989
109475 mm
1095Sand Cast Iron S & S as per IS : 3989
1096Providing Lead Caulked Joints to Sand Cast iron / centrifugally cast spun iron pipes and fittings of diameter :
1097100 mm dia pipe
109875 mm dia pipe
1099Providing and Fixing MS Stays and clamps for sand cast iron / centrifugally cast ( spun ) iron pipes of diameter :
1100100 mm dia pipe
110175 mm dia pipe
1102Providing and Fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete , including cost of cutting and making good the walls and floors .
1103100 mm inlet and 100 mm outlet
1104Sand Cast Iron S & S as per IS : 3989
1105Painting Sand cast iron / centrifugally cast ( spun ) iron soil , waste , vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey , or buff etc . Over a coat of primer ( of approved quality ) for new work :
1106100 mm diameter Pipes
110775 mm diameter Pipes
1108Providing and Fixing GI Pipes complete with GI Fittings and clamps including cutting and making good the walls etc .
1109Internal Work - Exposed on Wall
111032 mm dia nominal bore
111140 mm dia nominal bore
111250 mm dia nominal bore
1113Painting GI Pipes and Fittings with Synthetic enamel white paint with two coats over a ready mixed priming coat , both of approved quality for new work :
111432 mm diameter pipe
111540 mm diameter pipe
111650 mm diameter pipe
1117Providing and fixing multi-floor trap fitting with maximum 3 inlets 32,40 or 50 mm size fabricated from 100 dia GI pipes heavy duty and sockets,fixed to C.I. trap with Drip Seal joint and set in cement concrete as per standard drawing complete in all respect as directed by Engineer-in-charge.
1118Providing & fixing 100mm x 50mm G.I. waste with reducing elbow & nipple cutting chases, the floor / slab, repairs complete as required and connection to GI / CI waste pipe complete in all respect as directed by Engineer-in-charge.
1119Providing and fixing CP Brass floor cleanout plug / Clean out plug as per drawing complete with G.I. Socket jointed to drainage pipe outlet including drip seal joint complete in all respect as directed by Engineer-in-charge.
1120100 mm diameter Pipe
1121150 mm diameter Pipe
1122Providing and fixing Stainless Steel Grade (304) grating with ring and Stainless steel anti cockroach basket and two SS screw including fixing to the floor with cement mortar.
1123SUB HEAD - III : INTERNAL WATER SUPPLY
1124Providing and fixing G.I. Pipes complete with G.I. fittings and clamps,including cutting and making good the walls etc
112515 mm dia pipes
112620 mm dia pipes
112725 mm dia pipes
112832 mm dia pipes
112940 mm dia pipes
113050 mm dia pipes
1131Painting GI Pipes & Fittings with synthetic enamel white paint with two coats over a ready mixed priming coat , both of approved quality for new work .
113215 mm dia pipes
113320 mm dia pipes
113425 mm dia pipes
113532 mm dia pipes
113640 mm dia pipes
113750 mm dia pipes
1138Providing and Fixing GI Union in GI Pipe including cutting and threading the pipe and making long screws etc . Complete ( New Work )
113915 mm dia pipes
114020 mm dia pipes
114125 mm dia pipes
114232 mm dia pipes
114340 mm dia pipes
114450 mm dia pipes
114565 mm dia pipes
114680 mm dia pipes
1147Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and makin good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.)
114815 mm dia pipes
114920 mm dia pipes
115025 mm dia .Pipes.
115132 mm dia .Pipes.
1152Providing and fixing Thermoflex or Careflex thermal insulation tubing, a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber over pipes of following nominal bores and thickness including all required accessories complete as per specification.
11539 mm thick ( Pipe Inside the Toilets and Exposed in Shafts and Terrace )
1154For 15 mm dia Pipe
1155For 20 mm dia Pipe
1156For 25 mm dia Pipe
1157For 32 mm dia Pipe
1158For 40 mm dia Pipe
1159For 50 mm dia Pipe
1160Providing, fixing, testing and commissioning of motorised butterfly valve of following dia for filling of overhead water tank complete with high and low level control switches to control tanks. The level controllers shall be installed in overhead tanks. The level switch will close the valve when water level is high in overhead tank and open the valve when overhead water tank level is low. The system should be complete in all respects with accessories 220 V AC / 24 V DC, IP67 electrical water level control unit, copper control wiring in whether proof casing etc.
116140 mm dia Pipe
116250 mm dia Pipe
1163Providing and Fixing full way lever operated forged brass ball valve of brass body with forged brass hard chromeplated steel ball tasted to a pressure not less than 15 kg/sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc.
116415 mm dia
116520 mm dia
116625 mm dia
116732 mm dia
116840 mm dia
116950 mm dia
1170INTERNAL ELECTRICAL WORK (PRINCIPAL RESIDENCE )
1171SUB HEAD - I: CIRCUIT CUM POINT WIRING
1172SWITCH CONTROL LIGHT POINTS
1173Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. .
1174Group A
1175Group B
1176Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
1177Group A
1178Group B
1179MCB CONTROL LIGHT POINTS
1180Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Switch Control Primary Points)
1181Primary point controlled by one MCB.
1182Same as item above but Secondary point. i.e. Points to be looped with Primary point with 1.5 sqmm wire and Point wiring
1183Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
11842 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
11852 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
11862 X 4 sq. mm + 1 X 4 sq. mm earth wire
11872 X 6 sq. mm + 1 X 6 sq. mm earth wire
11882 x 10 sq. mm + 1 x 6 sq.mm earth wire
11894 X 10 sq. mm + 2 X 6 sq. mm earth wire
11904 X 16 sq. mm + 2 X 6 sq. mm earth wire
1191Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 Amp modular socket outlet and 5/6 A modular switch, connection etc. as required.
1192Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 Amp modular socket outlet and 15/16 A modular switch, connection etc. as required.
1193Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
1194Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 Amps modular SP MCB, “C” curve including connection, painting etc. as required. (AC's & Gysers)
1195Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
1196Telephone socket outlet
1197TV antenna socket outlet
1198Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
11991 or 2 Module (75mmX75mm)
12006 module (78mm X 205 mm X 50 mm)
1201Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
12023 pin , 5/6 amps socket outlet
12035/6 amps switch
1204Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
120525 mm
120632 mm
1207SUBHEAD -II - FITTINGS & FIXTURES
1208Supply, Installation, Testing and Commissioning of 10 W Bulk head Light.
1209Supply, Installation, Testing and Commissioning of 5W Mirror Light.
1210Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim
12118-10 Watt
121212-15 Watt
121318 Watt
1214Supplying, installation, Testing & Commissioning of LED (surface/wall) mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq. 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) Batten light (System lumen efficacy >135 lm/Watt)
121518-22 Watt
1216Supply, Installation, Testing and Commissioning of 10W (Nominal) Wall Bracket Light
1217Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (prefreably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req.
12181200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
1219Supply, installation, Testing and commissioning of 250mm Exhaust fan.
1220Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
1221SUBHEAD - III - DISTRIBUTION BOARDS
1222Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12236 way, Double door
12248 way, Double door
122512 way, Double door
1226Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator)
12276 way (4 + 18), Double door
12288 way (4 + 24), Double door
1229Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1230Single Pole
1231Single Pole Neutral
1232Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1233Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1234Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1235Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
1236SUB HEAD -IV - LT CABLES & CABLE TRAYS
1237Laying of one number PVC Insulated and PVC shethed /XLPE power Cables of 1.1 KV grade of following size direct in ground including excavation,sand cushioning and protecting covering and refilling the trench etc as required.
1238Up to 35 sq mm.
1239Above 35 sq mm and up to 95 sq mm.
1240Above 95 sq mm and up to 185 sq mm.
1241Laying of one number PVC insulated & PVC sheathed/ XLPE Power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required.
1242Upto 35 sq.mm
1243Above 35 sq. mm and upto 95 sq. mm
1244Above 95 sq.mm and upto 185 sq.mm
1245S/ F powder coated of approved shade MS Cable Trays
1246Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required..
1247100 mm width X 50 mm depth X 1.6 mm thickness
1248150 mm width X 50 mm depth X 1.6 mm thickness
1249300 mm width X 50 mm depth X 1.6 mm thickness
1250S/ F powder coated of approved shade MS Cable Tray Bends
1251Supplying and installing following size of perforated powder coated of approved shade M.S. cable tray bends with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
1252100 mm width X 50 mm depth X 1.6 mm thickness
1253150 mm width X 50 mm depth X 1.6 mm thickness
1254S/ F powder coated of approved shade MS Cable Tray Tee's
1255Supplying and installing following size of perforated powder coated of approved shade M.S. cable tray tee's with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
1256100 mm width X 50 mm depth X 1.6 mm thickness
1257150 mm width X 50 mm depth X 1.6 mm thickness
1258Supply of following sizes of XLPE insulated Aluminum conductor strip/ wire Armoured, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS-7098 Code and technical specifications.
12594 X 10 sq. mm (28mm)
12604 X 16 sq. mm (28mm)
12613½ X 35 sq. mm (32mm)
12623½ X 50 sq. mm (35mm)
12633½ X 95 sq. mm (38mm)
12643½ X 120 sq. mm (38mm)
1265XLPE Insulated Copper Armoured Cables
12662C x 6 Sq.mm.
12672C x 4 Sq.mm.
12683C x 6 Sq.mm.
12693C x 4 Sq.mm.
12704CX 2.5 Sq.mm
12714C x 4 Sq.mm.
1272Supply and making End termination with brass Single/ Double compression gland including providing and crimping of aluminum/copper solderless lugs/ferrules for XLPE/PVC insulated armoured power aluminum/copper conductor cables 1.1 KV grade of following sizes:
1273SINGLE COMPRESSION GLAND FOR AI. AR. CABLE
12744C/3C x 6/4 sq.mm.
1275Single Compression Gland for Cu. Cable
12764C/3C/2C x 4/6/2.5 sq.mm.
1277Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV gradeas required.
12784 X 10 sq. mm (25mm)
12794 X 16 sq. mm (28mm)
12803½ X 25 sq. mm (28mm)
12813½ X 35 sq. mm (32mm)
12823½ X 50 sq. mm (35mm)
12833½ X 95 sq. mm (45mm)
12843½ X 120 sq. mm (45mm)
1285SUB HEAD -V - EARTHING SYSTEM
1286Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
1287Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required.
1288Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
1289Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
1290SUB HEAD - VI :LIGHTNING CONDUCTOR
1291Earthing with Cu. earth Plate 600mm x 600mm x 3mm thick including accesssories, and providing masonary enclosure with cover plate (CI heavy duty) having locking arrangement and watering pipe of 2.7 mtr long etc. with charcoal or coke and salt ) as required.
1292Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
1293Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
1294Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
1295Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
1296Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
1297Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
1298Supply of Lightnig counter - LCD screen shows the number of lightning strikes, hour and date of lightning events Buttons enable TIME/DATE setting and log viewing. Replaceable battery, working life minimum five years, meet the requirements for IS/IEC 62305 and IEC 62561-2.Tested for Electrical ,Mechanical and Chemical as per IEC 62561.
12990.125 BOYS DORM. WITH 1 NOS. WARDEN RESIDENCE (G)
1300Earth Work
1301Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
1302Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
1303Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete.
1304Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
1305Concrete Work
1306Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 coarse sand (zone-iii) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
1307Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
1308Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
1309Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand,including necessary excavation,levelling & dressing & finishing the top smooth.
1310Brick edging in full brick width and half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1311Reinforced Cement Concrete
1312Centering and shuttering including strutting, propping etc. and removal of form for all heights :
1313Foundations, footings, bases of columns, etc. for mass concrete.
1314Suspended floors, roofs, landings, balconies and access platform.
1315Lintels, beams, plinth beams, girders, bressumers
1316Columns,Pillars, Piers, Abutments, Posts and Struts.
1317Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like
1318Edges of slabs and breaks in floors and walls Under 20 cm wide.
1319Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
1320Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500 D or more.
1321Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
1322Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
1323All works upto plinth level
1324Concrete of M25 grade with minimum cementcontent of 330 kg /cum
1325(i) R.C.C. work in Footing
1326(ii) R.C.C. work in Beam
1327(iii) R.C.C. work in Columns
1328All works above plinth level upto floor V level
1329Concrete of M25 grade with minimum cementcontent of 330 kg /cum
1330(i) R.C.C. work in Lintel
1331(ii) R.C.C. work in Beam
1332(iii) R.C.C. work in Columns
1333(iv) R.C.C. work in Slab
1334Masonry Work
1335Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)
1336Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
1337Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in superstructure above plinth level up to floor V level in : Cement mortar 1:6 (1 cement : 6 coarse sand)
1338Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
1339Cladding Work
1340Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
1341Granite stone slab colour black, Cherry/Ruby red
1342Area of slab upto 0.50 sqm
1343Area of slab over 0.50 sqm
1344Providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
1345Granite work
1346Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete.
1347Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
1348Providing and fixing Ist quality Glazed vitrified tiles polished finish of size 600 x 600 mm tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
1349Wood and PVC Work
1350Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
1351Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
1352Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
1353Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.
1354Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. Twin rubber stopper
1355Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws : 30 mm thick shutters With ISI marked stainless steel butt hinges of required size Kiln seasoned and chemically treated hollock wood
1356Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm.
1357Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm .
1358Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete.
1359200 x 10mm
1360150 x 10mm
1361CUPBOARD / WARDROBE
1362Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid board one side white color and otherside of board laminted with PVC foil of minimum 14 micronthickness of approved design pasted with hot melt adhesivefor cup boards, work stations and bathroom/kitchen cabinetetc. of required sizes comprising of virgin polymer of K value58-60 (Suspension Grade), calcium carbonate and natural fibers(wood powder/ rice husk/wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) having minimumdensity of 650 kg/cum and screw withdrawal strength of 1800N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spreadof flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixingwith stainless steel piano hinges/soft close clip on concealedhinges of required size with necessary full body threaded starheaded counter sunk S.S screws, all as per direction ofEngineer-In- Charge. (Note: stainless steel piano hinges/softclose clip on concealed hinges and necessary S.S screws shallbe paid separately)
136318 mm thick
136425 mm thick
1365Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid plain white color board for backingof cup boards and bathroom/kitchen cabinets etc. of requiredsize comprising of virgin polymer of K value 58-60 (SuspensionGrade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximumtoxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) &900 N (Edge), minimum compressive strength 50 N/mm2,modulus of elasticity 850 N/mm2 and resistance to spread offlame of Class A category with property of being termite/borerproof, water/moisture proof and fire retardant and fixing withstainless steel screws etc. all as per direction of Engineer-In-Charge. (Note: stainless steel screws shall be paid separately)
13666 mm thick
1367Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge. 200 mm
1368Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction ofEngineer-in-charge. 100 mm for Kitchen Cabinets
1369Providing and fixing stainless steel soft closing spring hinges at 0 degree hinges (hydraulic type) of approved make/brand tocupboard shutters with full threaded steel screws including making necessary recess in board and finished etc. complete as per direction of Engineer-in-charge
1370Providing and fixing stainless steel soft closing heavy type telescopic drawer channels of approved make 500 mm long with screws etc. complete as per directions of Engineer- in-charge.
1371Providing and fixing ready made 304 grade stainless steel Modular kitchen basket and accessories such as right angle basket (Plain Cup & Saucer, plant, Partition, Bottle rack, Thali, Cutlery) kitchen utensil basket, Dinner set basket, kitchen grain basket,Multipurpose basket as per site requirement including finishing (wherever required) and fittings. The same shall be fixed with necessary stainless steel nuts & bolts, Stainless Steel screws & telescopic channel etc. as per direction of Engineer-in-charge.(For payment purpose only weight of Stainless steel basket shall be considered excluding weight of all fixing accessories such as nuts, bolts, fasteners telescopic basket channels etc.Payment of providing and fixing telescopic channel shall be paid separately)
1372SS Hanging Rod for CB
1373Providing and fixing 25 mm dia. SS pipe Hanging rods with SS brackets :
1374Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade : Two or more coats on new work
1375Steel Work
1376Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
1377Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge.
1378Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes.
1379ALUMINIUM WORK
1380System Aluminium Factory made Double Rebate Windows with Grill and Mesh Providing and fixing of A2Z Series Double rebate windows & ventilators made of High-performance factory-made system Aluminium windows with Akzonobel powder coating of 60-70 microns (Any RAL Colour). Section for Outer frame should be a single section of 91mm x 35mm, Glass shutter frame shall be of 54mm x 30mm, Mesh shutter frame shall be of 54mm x 30mm, 5mm thick Single Glazed beading shall be of 15mm x 18mm. 5mm thick Clear Tuffened Glass shall be used in all the windows & ventilators. Stainless Steel Wire Mesh shall be used in Wire mesh Shutters. No Coupling of 2 windows shall be allowed in any type of design. 10mm Sq bar M.S. Grill/Guard bar with 150mm c/c shall be fixed in between glass & mesh shutter. All frame corners shall be joined/assembled using self-locating corner cleats (No screwing at corners shall be allowed). All Hardware shall be used from a reputed brand, weather silicon shall be used for filling the gap between window opening & window Frame complete in all respect including all taxes.
1381Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
1382For fixed portion
1383Powder coated aluminium (minimum thickness of powder coating 50 micron
1384For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
1385Powder coated aluminium (minimum thickness of powder coating 50 micron)
1386Providing and fixing 12 mm thick prelaminated particle board flatpressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screwsetc. complete as per architectural drawings and directions of engineerin-charge.
1387Pre-laminated particle board with decorative lamination on both sides
1388Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
1389With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)
1390Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor f nishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer in-charge. With stainless steel cover plate minimum 1.25 mm thickness
1391Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
1392Upto 5mm depth and 5 mm width
1393Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).
1394Flooring
1395Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Medium shade pigment using 50% white cement 50% Grey cement
1396Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
1397Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
1398Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of Size of Tile 600 x 600 mm
1399Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
1400Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
1401Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well a curvilinear portions of the building all complete as per the architecturaldrawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
1402Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent
1403Providing and fixing machine cut, mirror/ eggshell polished , granite work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charg .Granite of all colour except black, cherry/ruby red 18 mm thick (slab area above 0.50 sqm)
1404Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30mm thick (minimum) sheet, 1200 mm long spaced between main\\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
140512.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit.
1406Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
1407Finishing
1408External Plaster in CM 1:4 with18mm thick in Two coats comprising of first layer 12mm thick cement plaster finished with a top layer 6mm thick cement plaster cement: 4 coarse sand)
1409Rate for First layer 12mm thick cement plaster DSR item No. 13.4.1=Rs. 357.35
1410Rate for top layer 6mm thick cement plaster cement DSR item No. 13.4.1=Rs. 357.35/2=153.63
1411Total Rate For 18mm Thick Plaster=357.35+178.68=536.03
1412Extra for providing and mixing water proofing material in cement of plaster work in proportion recommended by the manufacturers.
141312mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. 1:6 (1 cement: 6 coarse sand)
14146 mm cement plaster on celling (a) 1:3(1 cement:3 fine sand)
1415Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats
1416Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
1417Steel Painting:Applying priming coat:
1418With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood
1419With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.
1420Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.
1421Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
1422Water Proofing
1423Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:
1424(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.
1425(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
1426(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.
1427(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.
1428(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”:
1429With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
1430PLUMBING ESTIMATE ( 0.125 BOYS DORM. 24 BEDDED )
1431SUB HEAD - I : SANITARY FIXTURES ( PROVIDING AND FIXING )
1432Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
1433White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
1434Providing and Fixing White Viterous China Extended wall mounting water closet of size 780 x 370 x 690 mm of approved shape including providing and fixing white viterous china cistern with dual flush fittings of flushing capacity 3 litre / 6 litre ( adjustable to 4 litre / 8 litre ) including seat cover and cistern fittings nuts bolts and gaskets etc complete .
1435Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat as lid,10 litre low level white P.V.C flushing cistern with manually controlled device (handle lever)conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.W.C. pan with ISI marked white solid plastic seat and lid
1436Providing and fixing wash basin with C.I. brackets 15 mm dia CP brass single hole basin mixer of approved quality and make including painting of fittings and brackets cutting and making good the walls wherever required
1437White Viterous china Wash basin size 550x400 mm with a 15 mm CP brass single hole basin mixer
1438Providing and Fixing Stainless Steel A ISI 304 ( 18/8 ) kitchen sink as per IS : 13983 with CI Brackets and stainless steel plug 40 mm , including painting of fittings and brackets , cutting and making good the walls wherever required .
1439Kitchen Sink with drain board
1440510 x 1040 mm bowl depth 250 mm
1441Providing and Fixing CP brass bib cock of approved quality conforming to IS : 8931
144215 mm nominal bore
1443Providing and Fixing CP brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms .
144415 mm nominal bore
1445Providing and Fixing CP brass angle valve for basin mixer and geyser points of approved quality conforming to IS : 8931
144615 mm nominal bore
1447Providing and Fixing CP brass stop cock ( concealed ) of standard design and of approved make conforming to IS : 8931
144815 mm nominal bore
1449Providing and placing on terrace ( at all floor levels ) polythylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet , outlet and overflow pipes but without fittings and the base support for tank .
1450Providing & fixing of Waste pipe for Wash basins & Sinks including pvc waste fittings complete.
145132 mm dia
145240 mm dia
1453Providing & fixing PTMT liquid soap container 109mm wide,125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour. weighing not less than 105 gms.
1454Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour,weighing not less than 88 gms.
1455Providing & fixing PTMT towel rail complete with brackets fixed to wooden cleats with C.P brass screws with concealed fitting arangement of approved quality and colour.
1456600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gram.less
1457Providing & fixing PTMT soap dish Holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting arrangements.Weighing not less than 106gms.
1458Providing & fixing 600 x 450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with CP brass Screws and washers complete .
1459Providing & fixing toilet paper holder:
1460C.P.brass
1461Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.
146215 mm nominal bore with 45cm length
1463Providing and fixing CP brass shower rose with 15 or 20 mm inlet
1464100 mm diameter
1465Providing & Fixing CP brass single lever telephonic wall mixer of quality and make as approved by engineer - in - charge .
146615 mm nominal dia
1467Providing and Fixing White Viterous China battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre and post flushing with water ( 250 ml and 500 ml consumption ) , having water inlet from back side , including fixing to wall with suitable brackets all as per manufacturer specification and direction of engineer - in - charge .
1468Providing & fixing C.P. brass Central hole wall mounted sink Mixer with aerator connecting legs & 2 nos CP brass wall flange and 2 nos CP brass stop cock including cutting & making good the walls wherever required complete in all respect as per direction of engineer - in - charge .
1469Providing and fixing C.P. brass Double coat hooks fixed in Toilet wall with C.P brass wall flanges & C.P. brass screws and other required accessories complete in all respect as per direction of engineer - in - charge .
1470Providing and fixing health faucet with 1 m CP brass flexible tube and swivel hook with CP brass wall flange including cutting & making good the walls wherever required complete in all respect as per direction of engineer in charge .
1471Providing and fixing vertical or horizontal storage type hot water heater electrical operated fixed to wall with anchor bolts & nuts, 15mm CP brass angle stop cock and 15mm CP brass non-return valve complete including making connections with 15mm dia CP connecting pipes on inlet and outlet, suitable length of power cable and 15 amps plug .
147215 Litre Capacity
147325 Litre Capacity
1474SUB HEAD - II : INTERNAL DRAINAGE (RAINWATER, SOIL, WASTE & FITTINGS)
1475Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 mx1 mx400 micron, finished 12 mm cement plaster 1:3 (1 cement:3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete
1476Providing and Fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams .
1477Providing and Fixing 100 mm diameter and 60 cm long rain water spout in cement mortar 1:4 ( 1 Cement : 4 Fine Sand )
1478Stone ware Spout
1479Providing and Fixing on wall face Unplasticised rigid pvc rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion .
1480Single Socketed Pipes
148175 mm diameter
1482110 mm diameter
1483Providing and Fixing on wall face Rigid Unplasticised UPVC moulded fittings / accessories for unplasticised Rigid PVC Rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion .
1484Coupler
148575 mm diameter
1486110 mm diameter
1487Single Push Fit Coupler
148875 mm diameter
1489110 mm diameter
1490Single Tee with door
149175x75x75 mm
1492110x110x110 mm
1493Single Tee without door
149475x75x75 mm
1495110x110x110 mm
1496Bend 87.5 degree
149775 mm bend
1498110 mm bend
1499Shoe ( Plain )
150075 mm Shoe
1501110 mm Shoe
1502Providing and Fixing unplasticised PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs , screwed with MS screws of required length , including cutting brick work with fixing in cement mortar 1:4 ( 1 Cement : 4 Coarse Sand ) and making good the wall etc . complete
150375 mm diameter
1504110 mm diameter
1505Providing and Fixing Soil , Waste and Vent Pipes :
1506100 mm dia
1507Centrifugally cast ( spun ) iron socket and spigot ( S & S ) pipe as per IS : 3989
150875 mm dia
1509Centrifugally cast ( spun ) iron socket and spigot ( S & S ) pipe as per IS : 3989
1510Providing and Filling the joints with spun yarn , cement slurry and cement mortar 1 : 2 ( 1 Cement : 2 fine Sand ) in SCI / CI Pipes :
151175 mm dia Pipe
1512100 mm dia Pipe
1513Providing and Fixing MS holder bat clamps of approved design to sand cast iron / cast iron ( spun ) pipe embedded in and including cement concrete blocks 10 x 10 x 10 cm of cement concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 graded stone aggregate 20 mm nominal sizes ) including cost of cutting holes and making good the walls etc .
1514For 100 mm dia Pipe
1515For 75 mm dia Pipe
1516Providing and Fixing Bend of Required degree with access door , insertion rubber washers 3 mm thick , bolts and nuts complete .
1517100 mm dia
1518Sand Cast iron S & S as per IS : 3989
1519Providing and Fixing Plain Bend of Required degree .
1520100 mm dia
1521Sand Cast iron S & S as per IS : 3989
1522Providing and Fixing Heel Rest Sanitary Bend
1523100 mm dia
1524Spun Cast Iron as per IS : 3989
1525Providing and Fixing Double Equal Junction of Required degree with access door , insertion rubber washer 3 mm thick , bolts and nuts complete .
1526100x100x100x100 mm
1527Spun Cast Iron as per IS : 3989
152875x75x75x75 mm
1529Spun Cast Iron as per IS : 3989
1530Providing and Fixing Single Equal Plain Junction of Required degree with access door , insertion rubber washer 3 mm thick , bolts and nuts complete .
1531100x100x100 mm
1532Sand Cast Iron S&S as per IS : 3989
153375x75x75 mm
1534Sand Cast Iron S&S as per IS : 3989
1535Providing and Fixing Single Unequal Junction of Required degree with access door , insertion rubber washer 3 mm thick , bolts and nuts complete .
1536100 x 100 x 75 mm
1537Sand Cast Iron S & S as per IS : 3989
1538Providing and Fixing Single Unequal Plain Junction of Required degree .
1539100 x 100 x 75 mm
1540Sand Cast Iron S & S as per IS : 3989
1541Providing and Fixing Sand Cast Iron S & S offsets as per IS : 3989
1542150 mm off sets
1543With 75 mm dia Pipe
1544With 100 mm dia Pipe
1545Providing and Fixing door piece , insertion rubber washer 3 mm thick , bolts and nuts complete .
1546100 mm
1547Spun Cast Iron as per IS : 3989
154875 mm
1549Spun Cast Iron as per IS : 3989
1550Providing and Fixing Terminal Guard :
1551100 mm
1552Sand Cast Iron S & S as per IS : 3989
155375 mm
1554Sand Cast Iron S & S as per IS : 3989
1555Providing and Fixing Collar :
1556100 mm
1557Sand Cast Iron S & S as per IS : 3989
155875 mm
1559Sand Cast Iron S & S as per IS : 3989
1560Providing Lead Caulked Joints to Sand Cast iron / centrifugally cast spun iron pipes and fittings of diameter :
1561100 mm dia pipe
156275 mm dia pipe
1563Providing and Fixing MS Stays and clamps for sand cast iron / centrifugally cast ( spun ) iron pipes of diameter :
1564100 mm dia pipe
156575 mm dia pipe
1566Providing and Fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete , including cost of cutting and making good the walls and floors .
1567100 mm inlet and 100 mm outlet
1568Sand Cast Iron S & S as per IS : 3989
1569Painting Sand cast iron / centrifugally cast ( spun ) iron soil , waste , vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey , or buff etc . Over a coat of primer ( of approved quality ) for new work :
1570100 mm diameter Pipes
157175 mm diameter Pipes
1572Providing and Fixing GI Pipes complete with GI Fittings and clamps including cutting and making good the walls etc .
1573Internal Work - Exposed on Wall
157432 mm dia nominal bore
157540 mm dia nominal bore
157650 mm dia nominal bore
1577Painting GI Pipes and Fittings with Synthetic enamel white paint with two coats over a ready mixed priming coat , both of approved quality for new work :
157832 mm diameter pipe
157940 mm diameter pipe
158050 mm diameter pipe
1581Providing and fixing multi-floor trap fitting with maximum 3 inlets 32,40 or 50 mm size fabricated from 100 dia GI pipes heavy duty and sockets,fixed to C.I. trap with Drip Seal joint and set in cement concrete as per standard drawing complete in all respect as directed by Engineer-in-charge.
1582Providing & fixing 100mm x 50mm G.I. waste with reducing elbow & nipple cutting chases, the floor / slab, repairs complete as required and connection to GI / CI waste pipe complete in all respect as directed by Engineer-in-charge.
1583Providing and fixing CP Brass floor cleanout plug / Clean out plug as per drawing complete with G.I. Socket jointed to drainage pipe outlet including drip seal joint complete in all respect as directed by Engineer-in-charge.
1584100 mm diameter Pipe
1585150 mm diameter Pipe
1586Providing and fixing Stainless Steel Grade (304) grating with ring and Stainless steel anti cockroach basket and two SS screw including fixing to the floor with cement mortar.
1587SUB HEAD - III : INTERNAL WATER SUPPLY
1588Providing and fixing G.I. Pipes complete with G.I. fittings and clamps,including cutting and making good the walls etc
158915 mm dia pipes
159020 mm dia pipes
159125 mm dia pipes
159232 mm dia pipes
159340 mm dia pipes
159450 mm dia pipes
1595Painting GI Pipes & Fittings with synthetic enamel white paint with two coats over a ready mixed priming coat , both of approved quality for new work .
159615 mm dia pipes
159720 mm dia pipes
159825 mm dia pipes
159932 mm dia pipes
160040 mm dia pipes
160150 mm dia pipes
1602Providing and Fixing GI Union in GI Pipe including cutting and threading the pipe and making long screws etc . Complete ( New Work )
160315 mm dia pipes
160420 mm dia pipes
160525 mm dia pipes
160632 mm dia pipes
160740 mm dia pipes
160850 mm dia pipes
160965 mm dia pipes
161080 mm dia pipes
1611Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and makin good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.)
161215 mm dia pipes
161320 mm dia pipes
161425 mm dia .Pipes.
161532 mm dia .Pipes.
1616Providing and fixing Thermoflex or Careflex thermal insulation tubing, a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber over pipes of following nominal bores and thickness including all required accessories complete as per specification.
16179 mm thick ( Pipe Inside the Toilets and Exposed in Shafts and Terrace )
1618For 15 mm dia Pipe
1619For 20 mm dia Pipe
1620For 25 mm dia Pipe
1621For 32 mm dia Pipe
1622For 40 mm dia Pipe
1623For 50 mm dia Pipe
1624Providing, fixing, testing and commissioning of motorised butterfly valve of following dia for filling of overhead water tank complete with high and low level control switches to control tanks. The level controllers shall be installed in overhead tanks. The level switch will close the valve when water level is high in overhead tank and open the valve when overhead water tank level is low. The system should be complete in all respects with accessories 220 V AC / 24 V DC, IP67 electrical water level control unit, copper control wiring in whether proof casing etc.
162540 mm dia Pipe
162650 mm dia Pipe
1627Providing and Fixing full way lever operated forged brass ball valve of brass body with forged brass hard chromeplated steel ball tasted to a pressure not less than 15 kg/sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc.
162815 mm dia
162920 mm dia
163025 mm dia
163132 mm dia
163240 mm dia
163350 mm dia
1634INTERNAL ELECTRICAL WORK ( 0.125 BOYS DORM. 24 BEDDED )
1635SUB HEAD - I: CIRCUIT CUM POINT WIRING
1636SWITCH CONTROL LIGHT POINTS
1637Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. .
1638Group A
1639Group B
1640Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
1641Group A
1642Group B
1643MCB CONTROL LIGHT POINTS
1644Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Switch Control Primary Points)
1645Primary point controlled by one MCB.
1646Same as item above but Secondary point. i.e. Points to be looped with Primary point with 1.5 sqmm wire and Point wiring
1647Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
16482 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
16492 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
16502 X 4 sq. mm + 1 X 4 sq. mm earth wire
16512 X 6 sq. mm + 1 X 6 sq. mm earth wire
16522 x 10 sq. mm + 1 x 6 sq.mm earth wire
16534 X 10 sq. mm + 2 X 6 sq. mm earth wire
16544 X 16 sq. mm + 2 X 6 sq. mm earth wire
1655Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 Amp modular socket outlet and 5/6 A modular switch, connection etc. as required.
1656Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 Amp modular socket outlet and 15/16 A modular switch, connection etc. as required.
1657Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
1658Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 Amps modular SP MCB, “C” curve including connection, painting etc. as required. (AC's & Gysers)
1659Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
1660Telephone socket outlet
1661TV antenna socket outlet
1662Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
16631 or 2 Module (75mmX75mm)
16646 module (78mm X 205 mm X 50 mm)
1665Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
16663 pin , 5/6 amps socket outlet
16675/6 amps switch
1668Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
166925 mm
167032 mm
1671SUBHEAD -II - FITTINGS & FIXTURES
1672Supply, Installation, Testing and Commissioning of 10 W Bulk head Light.
1673Supply, Installation, Testing and Commissioning of 5W Mirror Light.
1674Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim
16758-10 Watt
167612-15 Watt
167718 Watt
1678Supplying, installation, Testing & Commissioning of LED (surface/wall) mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq. 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) Batten light (System lumen efficacy >135 lm/Watt)
167918-22 Watt
1680Supply, Installation, Testing and Commissioning of 10W (Nominal) Wall Bracket Light
1681Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (prefreably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req.
16821200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
1683Supply, installation, Testing and commissioning of 250mm Exhaust fan.
1684Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
1685SUBHEAD - III - DISTRIBUTION BOARDS
1686Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
16876 way, Double door
16888 way, Double door
168912 way, Double door
1690Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator)
16916 way (4 + 18), Double door
16928 way (4 + 24), Double door
1693Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1694Single Pole
1695Single Pole Neutral
1696Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1697Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1698Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1699Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
1700SUB HEAD -IV - LT CABLES & CABLE TRAYS
1701Laying of one number PVC Insulated and PVC shethed /XLPE power Cables of 1.1 KV grade of following size direct in ground including excavation,sand cushioning and protecting covering and refilling the trench etc as required.
1702Up to 35 sq mm.
1703Above 35 sq mm and up to 95 sq mm.
1704Above 95 sq mm and up to 185 sq mm.
1705Laying of one number PVC insulated & PVC sheathed/ XLPE Power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required.
1706Upto 35 sq.mm
1707Above 35 sq. mm and upto 95 sq. mm
1708Above 95 sq.mm and upto 185 sq.mm
1709S/ F powder coated of approved shade MS Cable Trays
1710Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required..
1711100 mm width X 50 mm depth X 1.6 mm thickness
1712150 mm width X 50 mm depth X 1.6 mm thickness
1713300 mm width X 50 mm depth X 1.6 mm thickness
1714S/ F powder coated of approved shade MS Cable Tray Bends
1715Supplying and installing following size of perforated powder coated of approved shade M.S. cable tray bends with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
1716100 mm width X 50 mm depth X 1.6 mm thickness
1717150 mm width X 50 mm depth X 1.6 mm thickness
1718S/ F powder coated of approved shade MS Cable Tray Tee's
1719Supplying and installing following size of perforated powder coated of approved shade M.S. cable tray tee's with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
1720100 mm width X 50 mm depth X 1.6 mm thickness
1721150 mm width X 50 mm depth X 1.6 mm thickness
1722Supply of following sizes of XLPE insulated Aluminum conductor strip/ wire Armoured, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS-7098 Code and technical specifications.
17234 X 10 sq. mm (28mm)
17244 X 16 sq. mm (28mm)
17253½ X 35 sq. mm (32mm)
17263½ X 50 sq. mm (35mm)
17273½ X 95 sq. mm (38mm)
17283½ X 120 sq. mm (38mm)
1729XLPE Insulated Copper Armoured Cables
17302C x 6 Sq.mm.
17312C x 4 Sq.mm.
17323C x 6 Sq.mm.
17333C x 4 Sq.mm.
17344CX 2.5 Sq.mm
17354C x 4 Sq.mm.
1736Supply and making End termination with brass Single/ Double compression gland including providing and crimping of aluminum/copper solderless lugs/ferrules for XLPE/PVC insulated armoured power aluminum/copper conductor cables 1.1 KV grade of following sizes:
1737SINGLE COMPRESSION GLAND FOR AI. AR. CABLE
17384C/3C x 6/4 sq.mm.
1739Single Compression Gland for Cu. Cable
17404C/3C/2C x 4/6/2.5 sq.mm.
1741Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV gradeas required.
17424 X 10 sq. mm (25mm)
17434 X 16 sq. mm (28mm)
17443½ X 25 sq. mm (28mm)
17453½ X 35 sq. mm (32mm)
17463½ X 50 sq. mm (35mm)
17473½ X 95 sq. mm (45mm)
17483½ X 120 sq. mm (45mm)
1749SUB HEAD -V - EARTHING SYSTEM
1750Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
1751Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required.
1752Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
1753Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
1754SUB HEAD - VI :LIGHTNING CONDUCTOR
1755Earthing with Cu. earth Plate 600mm x 600mm x 3mm thick including accesssories, and providing masonary enclosure with cover plate (CI heavy duty) having locking arrangement and watering pipe of 2.7 mtr long etc. with charcoal or coke and salt ) as required.
1756Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
1757Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
1758Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
1759Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
1760Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
1761Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
1762Supply of Lightnig counter - LCD screen shows the number of lightning strikes, hour and date of lightning events Buttons enable TIME/DATE setting and log viewing. Replaceable battery, working life minimum five years, meet the requirements for IS/IEC 62305 and IEC 62561-2.Tested for Electrical ,Mechanical and Chemical as per IEC 62561.
1763FOOTPATH 2.00 MT. WIDE
1764Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge
1765Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work upto plinth level.
17661:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)s)
1767Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved s;ze, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
1768Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), ncluding making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
1769Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
1770Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
1771Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 5 km, also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc., complete.
1772Filling available excavated earth (excluding rock) in trenches, plinth, sides of oundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
1773Centering and shuttering including strutting, propping etc. and removal of form for all heights :
1774Foundations, footings, bases of columns, etc. for mass concrete.
1775ANALYSIS OF RATE FOR SURFACE DRAIN (150X250 MM)
1776Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
1777Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
1778Providing and laying in position cement concrete of specified grade excluding the cost of centering and shttering - All work up to plinth level
17791:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size).
1780Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stoneaggregate 12.5mm nominal size)
1781Centering and shuttering including strutting, propping etc. and removal of form for all heights :
1782Foundations, footings, bases of columns, etc. for mass concrete
1783Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in :
1784Cement mortar 1:6 (1 cement : 6 coarse sand)
178512 mm cement plaster finished with a floating coat of neat cement of mix :
17861:4 (1 cement: 4 fine sand)
1787BILL OF QUANTITIES FOR WATER SUPPLY
1788SUB HEAD (I) :- EXTERNAL WATER SUPPLY PIPES AND FITTINGS
1789DISTRIBUTION NETWORK FOR FRESH WATER SUPPLY
1790Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
1791External work
179220 mm dia nominal bore
179325 mm dia nominal bore
179432 mm dia nominal bore
179540 mm dia nominal bore
179650 mm dia nominal bore
179765 mm dia nominal bore
179880 mm dia nominal bore
1799Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality :
180020 mm diameter pipe
180125 mm diameter pipe
180232 mm diameter pipe
180340 mm diameter pipe
180450 mm diameter pipe
180565 mm diameter pipe
180680 mm diameter pipe
1807Providing and filling sand of grading zone V or coarser grade alround the GI pipes in external work.
180820mm dia nominal bore
180925mm dia nominal bore
181032mm dia nominal bore
181140mm dia nominal bore
181250 mm diameter pipe
181365 mm diameter pipe
181480 mm diameter pipe
1815Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) :
181650 mm dia
181780 mm dia
1818Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
181920 mm nominal bore
182025 mm nominal bore
182132 mm nominal bore
182240 mm nominal bore
182350 mm nominal bore
182465 mm nominal bore
182580 mm nominal bore
18261:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
1827Providing and fixing G.I. Union in GI pipe including cutting and threading the pipe and making long screws etc. complete(New work)
182825 mm nominal bore
182932 mm nominal bore
183040 mm nominal bore
183150 mm nominal bore
183265 mm nominal bore
183380 mm nominal bore
1834Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality
1835LD- 2.5
1836Rectangular shape 600*450 mm internal dimensions
1837Constructing masonry gate valve Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :
1838With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
1839Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
1840with common burnt clay F.P.S.(non module) brick of class designation 7.5
1841BILL OF QUANTITIES FOR SEWERAGE SYSTEM
1842SUB HEAD (I) :- EXTERNAL SEWERAGE SYSTEM
1843Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. anddisposing of surplus excavated soil as directed, within a lead of 50 m :
1844All kinds of soil
1845Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia
1846Supply and fixing HDPE double I.S 16098 ( Part - 2 ) 3013 for soil / waste pipe under ground drainage system with jointed with rubber ring with good quality lubricant for fittings, inclusive of all necessary specials like bends, tees, offsets, junctions, re excavtion and refillig etc complete.
1847200 mm dia.pipe
1848250 mm dia. pipe
1849Providing and laying in position cement concrete of specified grade excluding the cost of centering and shttering - All work up to plinth level 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size).
1850250 mm diameter Pipe (L*0.35*0.10=9.89)
1851250 mm diameter S.W. pipe (L*0.45*0.10=0.40)
1852Constructing brick masonry manhole in cement mortar 1 : 4 (1 cement : 4 coarse sand) with RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 grade stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1cement 3 coarse sand ) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finishd with a floating coat of neat cement complete as per standard design
1853Inside size 90 x 80 cm & 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimensions, total weight of cover & frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg)
1854With common burnt clay F.P.S.(non modular) bricks of classic designation 7.5
1855Extra for depth for manholes:
1856size 90 X 80 cm
1857With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1858Constructing Brick Masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top with FPS bricks class designation 75 in cement mortar 1:4 (1 cement : 4 Coarse sand), inside cement plaster 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of of neat cement, foundation concrete 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design.
18590.91m deep with SFRC cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S:12592, total weight of cover and frame to be not less than 182Kg. fixed in cement concrete 1:2:4 mix (1cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete.(Excavation foot rests and 12mm thick cement plaster at the external surface shall be paid for separately)
1860with common burnt clay F.P.S.(non module) brick of class designation 7.5
1861Extra depth for circuler type manholes 0.91 m internal dia ( at bottom ) beyond 0.91m to 1.67 m .
1862with common burnt clay F.P.S.(non module) brick of class designation 7.5
1863Providing and fixing square mouth S. W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design
1864180 x 150 mm. size P type
1865With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1866Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design :
1867With 20 mm dia round bar
1868ABSTRACT OF CUTTING FILLING WORK
1869Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.
1870Banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 m :
1871Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
1872Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
1873Hume pipe
1874Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
1875Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm
1876Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
1877450 mm dia. R.C.C. pipe
1878Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10 gradded stone aggregate 40 mm nominal size) alround S.W. Pipes including bed concrete as per standard design.
1879ANALYSIS OF RATE FOR SEPTIC TANK ( 50 USER'S) 2 NOS.
1880Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.
1881Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.
1882Earth work in Excavation 1.50-3.00 mtr
1883Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
1884Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
18851:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size).
1886Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).
1887Centering and shuttering including strutting, propping etc. and removal of form for:
1888Foundations, footings, bases of columns, etc. for mass concrete.
1889Walls (any thickness) including attached pilasters, butteresses,plinth and string courses etc.
1890Lintels, beams, plinth beams, girders, bressumers and cantilevers.
1891RCC Bend Beam
1892Suspended floors, roofs, landings, balconies and access platform.
1893Edges of slabs and breaks in floors and walls.
1894Under 20 cm wide
1895Providing and fixing tie bolt, spring coil and plastic cone in wall shuttering complete as per the direction of Engineer-in-charge.
1896Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.
18971:3 (1 cement: 3 fine sand)
18986 mm cement plaster on rough side of single or half brick wall of mix:
18991:3 (1 cement: 3 fine sand)
1900Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality
1901HD-20
1902Circular shape 560 mm internal diameter
1903Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
1904Providing and fixing soil, waste and vent pipes
1905100 mm dia.
1906Centrifugally cast (spun) iron socketed pipe as per IS: 3989.
1907Providing and fixing terminal guard :
1908Sand cast iron S&S as per IS - 3989
1909Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design.With F.P.S. bricks
1910ESTIMATE OF ELECTRICAL WORKS
1911SUBHEAD - I - MAIN BOARDS
1912Design, fabrication, assembly, wiring and supply of front operated dead front cubicle type compartmentalised as per Form 3B, rear access free standing, dust and vermin proof (IP 42 ingress protection) main switchboards suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for a symmetrical fault level of 50 kA at 415 volts, fabricated from 2 mm thick CRCA MS sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat sections including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc as per specifications, as required and as below.
1913(Note:The contractor may select the next higher fault rating of MCCB if it is not readily available ,without any extra cost ,as the figure indicated within the bracket are required maxmum fault level of the panel.)
1914FEEDER PILLAR
1915Design, Manufacturing, supplying, fixing in position, testing and commissioning of the following front operated front access 2mm thick CRCA steel enclosure free standing, water, dust and vermin proof outdoor type Feeder pillars with IP-55 protection hinged and lockable doors complete with interconnections copper crimping lugs, brass glands bonding to earth and painting, suitable for use at 415 volts, 3 phase 4 wire 50 Hz system . The panels fault withstanding capacity shall be of 25 MVA at 415 volts. All live accessories part shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be of colure coded with Heat shrinkable PVC insulated sleeves.
1916FEEDER PILLAR-1:
1917INCOMER
19181 No. 160A, 415V, Ics=25kA, 4P MCCB with thermal magnetic trip unit.
19191 No. Digital multifunction meter (V+A+Hz) with a set of cast resin CTs 160/5A.
19201 Set of Phase indicating lamp with MCB
1921BUS BARS-I :
1922200A TPN bus bars of aluminium alloy.
1923For emergency supply
19241 No. 63A, 415V, Ics=25kA, 4P MCCB with thermal magnetic trip unit.
19251 Set of On indicating lamp with MCB
1926BUS BARS-II :
1927100A TPN bus bars of aluminium alloy.
1928OUT GOING BUS-I :
19298 Nos. 63A 415V, 4P MCCB of 15kA .
19301 No. MCB Space.
1931OUT GOING BUS-II :
19325 Nos. 63A 415V, 4P MCB of 10kA .
19331 No. 40A 415V, 4P MCB of 10kA with 40A 4P Contactor & timer switch .
19342 Nos. 25A 415V, 4P MCB of 10kA .
19351 No. MCB Space.
1936METER BOARDS
1937Supply, installation, testing and commissioning of M.V. cubical type totally enclosed dust, dump and vermin proof Meter Bords complete with bus bars, MV danger notice plate, on surface ISI marked Electronic kWh meter, indication lamps, CT's, Interconnection with suitable capacity aluminium strips / rods, door covers, seperate compartment for each meter, glass inspection window, connection of incoming and outgoing cables with thimbles, powder coated having following incoming and outgoing MCBs MCCBs and kWh meters complete as required.
1938METER BOARDS
19391 No. 63A, 415V, Ics= 16kA, 4P MCCB with O/C, S/C protection & on indication lamp.
1940BUS BARS:
1941100A TPN bus bars of aluminium alloy.
1942OUT GOING:
19432 Nos. 40A DP MCB of 10kA with space for electronic direct kWh energy meter complete with all necessary wiring as per the Meter vendor requirement.
19447 Nos. 40A DP MCB of 10kA.
1945SUBHEAD - III - SUPPLYING & LAYING OF CABLE
1946L.T. CABLES
1947Supply of following sizes of XLPE insulated Aluminum conductor strip/ wire Armoured, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS-7098 Code and technical specifications.
19484 X 6 sq. mm
19494 X 10 sq. mm (28mm)
19504 X 16 sq. mm (28mm)
19513½ X 25 sq. mm (28mm)
19523½ X 35 sq. mm (32mm)
19533½ X 50 sq. mm (35mm)
19543½ X 150 sq. mm (50mm)
19553½ X 185 sq. mm (57mm)
19563½ X 240 sq. mm (62mm)
19573½ X 300 sq. mm (70mm)
1958Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
1959Upto 35 sq.mm
1960Above 35 sq. mm and upto 95 sq. mm
1961Above 95 sq.mm and upto 185 sq.mm
1962Above 185 sq.mm and upto 400 sq.mm
1963Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
19643½ X 25 sq. mm (28mm)
19653½ X 35 sq. mm (32mm)
19663½ X 50 sq. mm (35mm)
19673½ X 70 sq. mm (38mm)
19683½ X 95 sq. mm (45mm)
19693½ X 120 sq. mm (45mm)
19703½ X 150 sq. mm (50mm)
19713½ X 185 sq. mm (57mm)
19723½ X 240 sq. mm (62mm)
19733½ X 300 sq. mm (70mm)
19744 X 10 sq. mm (28mm)
19754 X 16 sq. mm (28mm)
1976Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
1977150 mm dia
1978300 mm dia
1979SUB HEAD -III : EARTHING SYSTEM
1980Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
1981Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
1982Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
1983Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
1984Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
1985Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56263209
AUTHORITY Government Departments
TENDER VALUE 6.86 Crore
LAST DATE 15-07-2026
Authority
Authority Name Uttar Pradesh Projects Corporation Limited
Work Description Tender for Conversion Of Sp Shed To Regular Staff Quarters Including Construction Of Additional Staff Quarters And 0.125 Unit Boys Dormitory With 01 No. Warden Residence At Jnv Darbhanga (Bihar)
Basic Detail
Tender No 23/GM(T)/UPPCL/2026-27/DATE 01.07.2026
Bidding Type Tender
Location
City Darbhanga
State Bihar
Key Dates
Publish Date 02 Jul 2026
Submission Date 15 Jul 2026
Open Date 15 Jul 2026
Finance
Tender Value 6.86 Crore
Tender Fee 17700
EMD 13.72 Lakhs
Exemption Not Available
Document List
BID.pdf
BOQ_2186495.xls
c163a129-bb49-4659-b17d-1dccb3f74930.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 02, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Jul 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
pdf

BID.pdf

xls

BOQ_2186495.xls

html

c163a129-bb49-4659-b17d-1dccb3f74930.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender